Comstock Park Safety Security Film RFP.pdf

PDF 600 KB Posted

Attached to
Request for School Safety / Security Window Film
Solicitation number
RFP-CPPS-190000000707-1
Issued by
Kent County, Michigan

About this file

This is a Request for Proposals (RFP) issued by Comstock Park Public Schools for the purchase and installation of safety and security window film across five school buildings. The RFP requires sealed bids to be submitted by March 15, 2019 at 12:00 noon to the Comstock Park Schools Administrative Office, with an optional pre-bid walk through scheduled for February 18, 2019 at 9:00 am. The work must be completed prior to August 15, 2019. The scope includes installation of security window film on numerous windows of varying sizes across Mill Creek Middle School, Pine Island Elementary, Comstock Park High School, Stoney Creek Elementary, and other district facilities, with detailed measurements provided for each location.

The project is funded through a Michigan State Police School Safety Grant. The district seeks bids offering the best materials at the lowest price to maximize the number of windows that can be outfitted within the grant amount. Bidders must provide familial disclosure documentation and certify they are not an Iran Linked Business. Technical specifications require 8 mil thick optically clear polyester film with pressure-sensitive adhesive, meeting various ASTM and safety standards including 400 ft-lbs impact resistance. The installation must include a wet glaze attachment system applied to all four sides of window frames, and bidders must provide references from five schools where they have completed similar installations.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Instructions to Bidders

SAFETY AND SECURITY WINDOW FILM

The Comstock Park Public Schools Board of Education is accepting bids for the purchase and installation of safety and security window film.

Inquiries of a technical nature may be directed to Chris LaHaie, Director of Finance and

Operations at clahaie@cppschools.com.

An optional pre-bid walk through will occur at 9:00 am on Monday, February 18, 2019 to begin at Comstock Park Schools Central Office, 101 School Street NE, Comstock Park, MI 49321. All work must be completed prior to August 15, 2019.

Your proposal marked, “SEALED BID: COMSTOCK PARK PUBLIC SCHOOLS - SAFETY AND SECURITY WINDOW FILM" will be accepted NO LATER THAN 12:00 NOON, March 15, 2019, TO:

COMSTOCK PARK SCHOOLS ADMINISTRATIVE OFFICE

Attn: Chris LaHaie Director of Finance & Operations

101 School Street NE Comstock Park, MI 49321.

Oral, telephone, fax, or electronic mail bids are invalid and will not receive consideration.

All bids will be publicly opened and read aloud on Friday, March 15, 2019 at Noon at the Comstock Park Public Schools Board Room, 101 School Street NE, Comstock Park, MI 49321.

All bidders must provide familial disclosure in compliance with MCL 380.1267 and attach this information to the bid proposal. The bid proposal will be accompanied by a sworn and notarized statement disclosing any familial relationship that exists between the owner or any employee of the bidder and any member of the Comstock Park Public Schools Board of Education or the

Comstock Park Public Schools Superintendent. All bids must also be accompanied by a sworn and notarized statement certifying that the Contractor is not an Iran Linked Business within the meaning of the Iran Economic Sanctions Act of 2012. The District will not accept a bid proposal that does not include these sworn and notarized disclosure statements.

The Board of Education reserves the right to accept or reject any or all bids, either in whole or in part; to award contract to other than the low bidder; to waive any irregularities and/or informalities; and in general to make awards in any manner deemed to be in the best interests of the owner.

General Requirements

Comstock Park Public Schools was the recipient of a Michigan State Police School Safety Grant.

As written in the Grant detail, we require installation of safety and security window films on the windows of our five (5) building locations detailed below. We understand that we are not security film experts, so we will be looking for bids that offer the best materials at the lowest price so we may outfit as many windows as possible with the amount awarded in our Grant.

Quantity Description Dimension

4 Exterior Side Glass Wall 33x43

4 Exterior Side Glass Wall 33x33

2 Exterior Entryway Glass 43x33

2 Exterior Entryway Glass 33x37

2 Exterior Entryway Glass 24x24

2 Exterior Entryway Glass 24x38

2 Exterior Entryway Glass 17x44

2 Exterior Entryway Glass 17x37

2 Exterior Entryway Glass 24x33

2 Exterior Entryway Glass 24x24

2 Exterior Entryway Glass 10x44

2 Exterior Entryway Glass 10x36

2 Exterior Entryway Glass 24x34

2 Exterior Entryway Glass 24x24

1 Exterior Entryway Glass 30x44

1 Exterior Entryway Glass 30x36

1 Exterior Entryway Glass 24x24

1 Exterior Entryway Glass 24x34

16 Exterior Casement 36x37

3 Exterior Entryway Glass 24x37

3 Exterior Entryway Glass 24x24

3 Exterior Entryway Glass 19x31

3 Exterior Entryway Glass 19x25

2 Exterior Entryway Glass 33x37

2 Exterior Entryway Glass 33x36

2 Exterior Entryway Glass 24x36

2 Exterior Entryway Glass 24x36

4 Exterior Entryway Glass 26x36

2 Exterior Entryway Glass 15x34

2 Exterior Entryway Glass 15x24

1 Exterior Entryway Glass 5x40

4 Exterior Entryway Glass 36x27

2 Exterior Entryway Glass 24x26

2 Exterior Entryway Glass 24x36

2 Exterior Entryway Glass 14x36

33 Classroom Casement 44x36

56 Classroom Casement 34x34

8 Classroom Casement 21x47

8 Classroom Casement 35x47

18 Cafeteria Glass 20x44

11 Cafeteria Glass 8x40

4 Cafeteria Glass 20x34

4 Cafeteria Glass 20x24

31 Interior Door Glass 6x36

54 Interior Glass 21x18

27 Interior Door Glass 8x40

22 Interior Door Glass 5x20

13 Interior Glass 35x18

13 Interior Glass 43x18

2194 Exterior Entryway Glass

Mill Creek Middle School, 100 Betty Street NE, Comstock Park, MI 49321

Quantity Description Dimension

8 Exterior Entryway Glass 36x60

12 Exterior Door Glass 22x35

12 Exterior Door Glass 22x19

156 Classroom Casement 22x29

78 Classroom Casement 44x29

8 Casement 44x29

9 Casement 21x44

8 Library Glass 33x58

4 Library Glass 38x58

2 Library Door Glass 19x23

2 Library Door Glass 33x23

50 Interior Door Glass 7x40

20 Interior Casements 44x58

54 Interior Door Glass 13x28

6 Interior Casement 33x58

6 Interior Casement 33x58

3 Interior Entryway Glass 35x58

5 Interior Entryway Glass 20x34

5 Interior Entryway Glass 20x34

1 Interior Entryway Glass 20x58

2794 Linear Feet Wet Glaze

Pine Island Elementary, 6101 Pine Island Dr, Comstock Park, MI 49321

11 Exterior Front Entryway 24x34

11 Exterior Front Entryway 24x35

4 Exterior Front Entryway 14x40

14 Classroom Casement 40x40

93 Classroom Casement 45x45

1 Interior Front Entryway 22x32

1 Interior Front Entryway 22x29

1 Interior Front Entryway 7x36

8 Interior Front Entryway 50x40

39 Interior Casement 21x44

40 Interior Casement 7x30

3 Interior Casement 36x15

42 Interior Casement 7x29

165 Interior Casement 21x31

90 Interior Casement 21x55

5 Interior Casement 43x43

4 Interior Casement 24x25

4 Interior Casement 24x36

5 Interior Casement 42x21

17 Exterior Glass Athletic Wing 39x108

1 Exterior Glass Athletic Wing 40x123

1 Exterior Glass Athletic Wing 15x123

1 Exterior Glass Athletic Wing 12x123

6 Exterior Athletic Entryway 25x34

6 Exterior Athletic Entryway 25x27

5 Interior Glass Athletic Wing 43x36

14 Interior Glass Athletic Wing 21x36

1 Interior Glass Athletic Wing 18x34

1 Interior Glass Athletic Wing 18x36

2 Interior Glass Athletic Wing 33x43

4 Exterior Entryway Glass 24x33

4 Exterior Entryway Glass 24x27

2 Exterior Entryway Glass 21x67

10 Exterior Casement 66x50

10 Exterior Casement 66x17

2 Exterior Entryway Glass 24x34

2 Exterior Entryway Glass 24x37

2 Exterior Entryway Glass 30x50

2 Exterior Entryway Glass 30x17

6 Exterior Casement 18x72

6 Exterior Casement 47x72

5 Exterior Casement 66x42

5 Exterior Casement 66x21

4 Exterior Entryway Glass 12x42

2 Exterior Entryway Glass 24x34

2 Exterior Entryway Glass 24x27

4 Exterior Entryway Glass 24x34

4 Exterior Entryway Glass 24x27

8 Exterior Casement 41x36

12 Exterior Casement 45x51

1 Exterior Casement 45x46

2 Exterior Casement 46x55

12 Exterior Casement 48x51

1 Exterior Casement 48x46

2 Exterior Casement 48x55

12 Exterior Casement 16x51

1 Exterior Casement 16x46

2 Exterior Casement 16x55

4 Exterior Casement 28x31

11 Exterior Casement 20x20

2 Exterior Entryway Glass 24x36

2 Exterior Entryway Glass 24x30

4 Exterior Entryway Glass 18x29

4062 Linear Feet Wet Glaze

Comstock Park High School, 150 6 Mile Rd NE, Comstock Park, MI 49321

Quantity Description Dimension

1 Exterior Entryway Glass 36x43

1 Exterior Entryway Glass 29x43

1 Exterior Entryway Glass 60x43

1 Exterior Entryway Glass 33x42

1 Exterior Entryway Glass 33x31

2 Exterior Entryway Glass 33x27

1 Exterior Entryway Glass 42x68

2 Exterior Entryway Glass 35x68

1 Exterior Entryway Glass 31x68

1 Exterior Entryway Glass 25x42

2 Exterior Entryway Glass 23x35

1 Exterior Entryway Glass 17x31

1 Exterior Entryway Glass 17x71

2 Exterior Entryway Glass 12x36

2 Exterior Entryway Glass 17x55

2 Exterior Entryway Glass 17x31

15 Exterior Door Glass 25x25

15 Exterior Door Glass 25x23

8 Exterior Door Glass 20x31

8 Exterior Door Glass 20x41

2 Exterior Entryway Glass 15x31

2 Exterior Entryway Glass 15x41

6 Casement 43x29

6 Casement 43x50

2 Classroom Glass Half Wall 28x43

2 Classroom Glass Half Wall 28x10

10 Classroom Glass Half Wall 39x43

10 Classroom Glass Half Wall 39x12

32 Classroom Glass Half Wall 35x43

32 Classroom Glass Half Wall 35x10

66 Classroom Glass Half Wall 32x40

66 Classroom Glass Half Wall 32x10

35 Classroom Glass Half Wall 42x43

35 Classroom Glass Half Wall 42x10

1 Classroom Glass Half Wall 21x43

1 Classroom Glass Half Wall 21x10

24 Classroom Casements 32x48

24 Classroom Casements 32x23

2 Classroom Casements 33x43

2 Classroom Casements 24x32

2 Classroom Casements 24x28

4 Classroom Casements 38x55

4 Classroom Casements 38x31

28 Classroom Casements 32x49

6 Classroom Casements 24x49

6 Interior Entryway Glass 28x43

2 Interior Entryway Glass 15x30

2 Interior Entryway Glass 15x25

3 Interior Entryway Glass 24x31

3 Interior Entryway Glass 24x26

40 Interior Door Glass 6x38

4 Interior Glass 21x38

20 Interior Glass 17x38

14 Interior Glass 13x38

8 Interior Glass 15x38

10 Interior Glass 24x38

2 Interior Casement 41x62

5001 Linear Feet Wet Glaze

Stoney Creek Elementary, 200 Lantern Dr. NW, Comstock Park, MI 49321

10 Gym Glass 27x54

8 Front Entryway Glass 33x50

8 Front Entryway Glass 33x26

8 Front Entryway Glass 33x8

2 Front Entryway Glass 27x34

2 Front Entryway Glass 27x23

2 Front Entryway Glass 36x8

3 Classroom Glass Half Wall 39x43

3 Classroom Glass Half Wall 39x9

30 Classroom Glass Half Wall 31x40

30 Classroom Glass Half Wall 31x6

4 Classroom Glass Half Wall 37x43

4 Classroom Glass Half Wall 37x6

14 Classroom Glass Half Wall 41x43

14 Classroom Glass Half Wall 41x6

10 Classroom Glass Half Wall 36x43

10 Classroom Glass Half Wall 36x6

2 Exterior Entryway Glass 17x39

2 Exterior Entryway Glass 17x30

22 Exterior Entryway Glass 13x39

2 Exterior Entryway Glass 13x30

4 Exterior Entryway Glass 24x34

4 Exterior Entryway Glass 24x30

27 Classroom Casements 31x49

2 Classroom Casements 27x53

24 Classroom Casements 27x40

24 Classroom Casements 27x8

4 Classroom Casements 30x40

6 Interior Entryway Glass 36x8

6 Interior Entryway Glass 36x46

6 Interior Entryway Glass 36x30

2 Interior Entryway Glass 25x32

2 Interior Entryway Glass 25x24

1 Interior Entryway Glass 72x8

18 Interior Glass 10x54

6 Interior Glass 22x50

6 Interior Glass 10x40

7 Interior Glass 22x50

7 Interior Glass 22x23

2780 Linear Feet Wet Glaze

Greenridge Elementary, 3825 Oakridge Ave. NW, Comstock Park, MI 49321

Company Name by (Signature)

Address Print Name

Date Title

Phone Email

Bid Requirements and Specifications

Safety and Security Window Film

Material and Installation Specifications and Attachment System

SAFETY AND SECURITY WINDOW FILM

PART 1 GENERAL

1.1 SECTION INCLUDES

Safety and Security Window Film specifications:

A. ANSI Z97.1 - American National Standard for Safety Glazing Materials Used in Buildings -

Safety Performance Specifications and Methods of Test.

B. ASHRAE - American Society for Heating, Refrigeration, and Air Conditioning Engineers;

Handbook of Engineers.

C. ASTM International (ASTM):

1. ASTM D 882 - Standard Test Method for Tensile Properties of Thin Plastic

Sheeting.

2. ASTM D 1004 - Standard Test Method for Tear Resistance (Graves Tear) of Plastic

Film and Sheeting.

3. ASTM D 1044 - Standard Method of Test for Resistance of Transparent Plastics to

Surface Abrasion (Taber Abrader Test).

4. ASTM D 2582 - Standard Test Method for Puncture-Propagation Tear Resistance of Plastic Film and Thin Sheeting.

5. ASTM D 4830 - Standard Test Methods for Characterizing Thermoplastic

Fabrics Used in Roofing and Waterproofing.

6. ASTM E 84 - Standard Method of Test for Surface Burning Characteristics of

Building Materials.

7. ASTM E 903 - Standard Methods of Test for Solar Absorbance, Reflectance and Transmittance of Materials Using Integrating Spheres.

8. ASTM E 1886 - Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and

Exposed to Cyclic Pressure Differentials.

9. ASTM E 1996 - Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes.

10. ASTM F 1642 - Standard Method of Test for Glazing and Glazing Systems Subject to Airblast Loadings.

11. ASTM F 2912 - Standard Specification for Glazing and Glazing Systems Subject to Airblast Loadings.

D. Consumer Products Safety Commission 16 CFR, Part 1201 - Safety Standard for Architectural Glazing Materials.

E. GSA-TSOI - Standard Test for Glazing and Glazing Systems Subject to Airblast Loadings.

F. NFRC 100/200 (Formerly ASTM E903) - Standard Methods of Test for Solar Absorbance, Reflectance and Transmittance of Materials Using Integrating Spheres.

G. ISO 16933, International Standard for Glass in Building: Explosion-resistant security glazing - Test and classification for arena air-blast testing.

1.2 PERFORMANCE REQUIREMENTS

A. Safety Glazing Impact Performance:

1. 400 ft-lbs impact resistance, meeting ANSI Z97.1 (Class A, Unlimited) and 16 CFR 1201 (Category 2) impact requirements with film applied on 1/4 inch annealed glass.

2. Impact Resistance after Aging: 400 ft-lbs, meeting ANSI Z97.1 (Class A, Unlimited) and 16

CFR 1201 (Category 2) impact requirements with film applied on 1/8 inch annealed glass.

B. Blast Hazard Mitigation Performance:

1. GSA Rating of "2"/ ASTM F 1642 "No Hazard" with minimum blast load of 9 psi and 63 psi*msec, on 1/4" single pane glass and film attachment system.

2. GSA Rating of "2" / ASTM F 1642 "Minimal Hazard" with minimum blast load of 10 psi and 89 psi*msec, on 1 inch (25 mm) double pane glass and film attachment system.

3. GSA Rating of "3B" / ASTM F 1642 "Very Low Hazard" with minimum blast load of 5 psi and 28 psi*msec, on 1/4" pane glass without film attachment system.

4. GSA Rating of "3B" / ASTM F 1642 "Low Hazard" with blast minimum load of 10 psi and 42 psi*msec, on 1 inch (25 mm) double pane glass without film attachment system.

C. Impact Resistance and Pressure Cycling:

1. ASTM El 996 / El 886: Large Missile +1- 75 psf Design Pressure

D. Tear Resistance:

1. Minimum Graves Area Tear Strength of 1 1200 lbs% as measured on coated film product, without liner, per ASTM DI 004.

E. Adhesion to Glass:

1. Minimum 6 lbs/in peel strength per ASTM D3330 (Method A).

F. Flammability: Surface burning characteristics when tested in accordance ASTM E 84, demonstrating film applied to glass rated Class A for Interior Use:

1. Flame Spread Index: no greater than 25.

2. Smoke Developed Index: no greater than 55.

G. Abrasion Resistance:

1. Film shall have a surface coating that is resistant to abrasion such that less than 3 percent increase of transmitted light haze will result when tested in accordance to ASTM D 1044 using 100 cycles, 500 grams weight, and the CSIOF Calibrase Wheel.

H. UV Light Rejection:

1. Minimum of 99.9% UV light rejection (300 - 380 nm), per ASTM E903, as determined with film applied on 1/4 inch clear glass.

1.3 SUBMITTALS

A. Submit under provisions of Section 01 30 00 - Administrative Requirements.

B. Product Data: Manufacturer's current technical literature on each product to be used, including:

1. Manufacturer's Data Sheets.

2. Preparation instructions and recommendations.

3. Storage and handling requirements and recommendations.

4. Installation methods.

C. 3rd Party Test Report Submittal Requirements. Submit the following 3rd Party test reports indicating compliance with the test values listed in this section.

1. Flammability Testing, ASTM E84.

2. Film Properties Testing, ASTM D882.

3. Abrasion Resistance Testing, ASTM DI 044.

4. Peel Strength Testing, ASTM D3330.

5. Tear Resistance Testing, ASTM D1004.

6. Puncture Strength Testing, ASTM D4830.

7. Safety Glazing Impact Testing, ANSI Z97.1 and/or 16 CFR 1201.

8. Impact Resistance and Pressure Cycling, ASTMs El 886 and El 996.

9. Blast Hazard Mitigation Testing ASTM F1642 / F2912 and/or GSA-TS01-2003.

D. Other Product Submittals:

1. Manufacturer's summary of 3rd Party Blast Hazard Mitigation Testing, ASTM F 1642 /

F2912 and/or GSA-TS01-2003

2. 3rd Party test reports from Forced Entry Resistance evaluations.

E. Verification Samples: For each film specified, two samples representing actual film color and pattern.

1.4 QUALITY ASSURANCE

A. Manufacturer Qualifications: All primary products specified in this section will be supplied by a manufacturer with a minimum of five years experience.

1. Provide documentation that the adhesive used on the specified films is a Pressure

Sensitive Adhesive (PSA).

B. Installer Qualifications: All products listed in this section are to be installed by a single installer with a minimum of five years demonstrated experience in installing products of the same type and scope as specified.

1. Provide documentation that the installer is authorized by the Manufacturer to perform Work specified in this section.

2. Provide a commercial building reference list of 5 properties where the installer has applied window film. This list will include the following information:

a. Name of building.

b. The name and telephone number of a management contact.

c. Type of glass.

d. Type of film and/or film attachment system.

e. Amount of film and/or film attachment system installed.

f. Date of completion.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Follow Manufacturer's instructions for storage and handling.

B. Store products in manufacturer's unopened packaging until ready for installation.

C. Store and dispose of hazardous materials, and materials contaminated by hazardous materials, in accordance with requirements of local authorities having jurisdiction.

1.6 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.7 WARRANTY

A. At project closeout, provide to Owner or Owners Representative an executed current copy of the manufacturer's standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: 3M Window Film.

B. Acceptable Manufacturer: Eastman Chemical.

C. Acceptable Manufacturer: Solar Gard.

A. Safety and Security Window Film. Optically clear polyester film, nominally 8 mils (0.008 inch) thick, with a durable acrylic abrasion resistant coating over one surface and a pressure sensitive adhesive on the other. The film is clear and does not contain dyed polyester. The adhesive is pressure-activated, not water-activated, and forms a physical bond, not chemical bond, to the glass. The film is microlayered or multilayered.

1 . Physical / Mechanical Performance Properties (nominal):

a. Film Color: Clear.

b. Film Thickness (excluding coatings or adhesive liner): Nominal 8 mils

c. Tensile Strength (ASTM D882)

d. Break Strength (ASTM D882)

e. Percent Elongation at Break (ASTM D882)

f. Percent Elongation at Yield (ASTM D882)

g. Graves Tear Resistance (ASTM DI 004):

h. Puncture Strength (ASTM D4830)

2. Impact Resistance and Pressure Cycling: Film shall pass impact of Large Missile "C" and withstand subsequent pressure cycling (per ASTMs El 996 and El 886) at +1 75 psf Design

Pressure with use of 3M Impact Protection Adhesive or other manufacturers attachment system. Film applied to 1/4-inch tempered glass.

3. Blast Hazard Mitigation:

a. GSA Rating of "2" / ASTM F 1642 "Minimal Hazard" with blast pressure of 7 psi and

44 psi*msec blast impulse, on 1/4 inch (6 mm) annealed single pane glass and 3M

Impact Protection Profile Attachment system.

b. GSA Rating of "2"/ ASTM F 1642 "Minimal Hazard" with blast pressure of 7 psi and

43 psi*msec blast impulse, on 1/4 inch (6 mm) tempered single pane glass and 3M

Impact Protection Profile Attachment system

c. GSA Rating of "2" / ASTM F 1642 "Minimal Hazard" with blast pressure of 9 psi and

62 psi*msec blast impulse, on 1/4 inch (6 mm) annealed single pane glass and 3M

Impact Protection Adhesive Attachment system.

d. GSA Rating of "2' / ASTM F 1642 "No Hazard" with blast pressure of 9 psi and 63 psi*msec blast impulse, on 1/4 inch (6 mm) tempered single pane glass and 3M Impact Protection Adhesive Attachment system.

e. GSA Rating of "2" / ASTM F 1642 "Minimal Hazard" with blast pressure of 9 psi and

60 psi*msec blast impulse, on 1 inch (25 mm) annealed double pane glass and 3M Impact Protection Profile Attachment system.

f. GSA Rating of "2" / ASTM F 1642 "Minimal Hazard" with blast pressure of 10 psi and

89 psi*msec blast impulse, on 1 inch (25 mm) annealed double pane glass and 3M Impact Protection Adhesive Attachment system.

g. GSA Rating of "3B" / ASTM F 1642 "Very Low Hazard" with blast pressure of 4 psi and 28 psi*msec blast impulse, on 1/4 inch (6 mm) annealed single pane glass, daylight applied film (no attachment).

h. GSA Rating of "3B" / ASTM F 1642 "Very Low Hazard" with blast pressure of 4 psi and 28 psi*msec blast impulse, on 1/4 inch (6 mm) tempered single pane glass, daylight applied film (no attachment).

i. GSA Rating of "3B" / ASTM F 1642 "Low Hazard" with blast pressure of 7 psi and 42 psi*msec blast impulse, on 1 inch (25 mm) annealed double pane glass, daylight applied film (no attachment).

4. Forced Entry Resistance: Product shall have been evaluated for time to resist complete body passage by a qualified 3rd Party test lab.

PART 3 EXECUTION

3.1 EXAMINATION

A. Film Examination:

1. If preparation of glass surfaces is the responsibility of another installer, notify District in writing of deviations from manufacturer's recommended installation tolerances and conditions.

2. Glass surfaces receiving new film should first be examined to verify that they are free from defects and imperfections, which will affect the final appearance.

3. Do not proceed with installation until glass surfaces have been properly prepared and deviations from manufacturer's recommended tolerances are corrected. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result under the project conditions.

4. Commencement of installation constitutes acceptance of conditions.

3.2 PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

C. Refer to Manufacturer's installation instructions for methods of preparation for Impact

Protection Adhesive or Impact Protection Profile film attachment systems.

3.3 INSTALLATION

A. Film Installation, General:

1. Install in accordance with manufacturer's instructions.

2. Cut film edges neatly and square at a uniform distance of 1/8 inch (3 mm) to 1/16 inch

(1.5 mm) of window sealant. Use new blade tips after 3 to 4 cuts.

3. Upon completion of film application, allow 30 days for moisture from film installation to dry thoroughly, and to allow film to dry flat with no moisture dimples when viewed under normal viewing conditions.

4. For exterior application, check with the manufacturer as to whether edge sealing is required.

3.4 CLEANING AND PROTECTION

A. Remove left over material and debris from Work area. Use necessary means to protect film before, during, and after installation.

B. Touch-up, repair or replace damaged products before Substantial Completion.

C. After application of film, wash film using common window cleaning solutions, including ammonia solutions, 30 days after application. Do not use abrasive type cleaning agents and bristle brushes to avoid scratching film. Use synthetic sponges or soft cloths.

PART 4 - ANCHORING OR ATTACHMENT

Film to frame attachment system

A. 3m Impact Protection Adhesive System or the Dow Corning 995 Silicone Structural

Sealant. Apply wet glaze attachment to all four sides of the frame.

B. Supply reference list of five schools where you have completed a wet glaze or mechanical type attachment system.

References

List references for similar services provided for at least five (5) clients in the past five (5) years.

Client 1 :

Organization Name:

Contact Name: Phone:

Project(s)

Client 2 :

Client 3 :

Client 4 :

Client 5 :

AFFIDAVIT OF BIDDER

The undersigned, the owner or authorized officer of (The Bidder), pursuant to the familial disclosure requirement provided in the

(the School District) advertisement for construction bids, hereby represent and warrant, except as provided below, that no familial relationships exist between the owner(s) or any employee of and any member of the Board of Education of the School District or the Superintendent of the School District.

List any Familial Relationships:

Bidder:

By:

Its:

STATE OF MICHIGAN

COUNTY OF

This instrument was acknowledged before me on the day of , 2019, by

Notary Public

County, Michigan My

Commission Expires:

Acting in the County of:

AFFIDAVIT OF COMPLIANCE - IRAN ECONOMIC SANCTIONS ACT

Michigan Public Act No. 517 of 2012

The undersigned, the owner or authorized officer of the below-named applicant (the "Applicant"), pursuant to the compliance certification requirement provided in the Comstock Park Public Schools (the "School District") Request For Proposals (the "RFP"), hereby certified, represents and warrants that the Applicant *(including its officers, directors and employees) is not an "Iran linked business" within the meaning of the Iran Economic Sanctions Act, Michigan Public Act No. 517 of 2012 (the "Act"), and that in the event Applicant is awarded a contract as a result of the aforementioned RFP, the Applicant will not become an "Iran linked business" at any time during the course of performing any services under the contract.

The Contract further acknowledges that any person who is found to have submitted a false certification is responsible for a civil penalty of not more than $250,000.00 or 2 time the amount of the contract or proposed contract for which the false certification was made, whichever is greater, the cost of the School District's investigation, and reasonable attorney fees, in addition to the fine. Moreover, any person who submitted a false certification shall be ineligible to bid on a request for proposal for three (3) years from the date that it is determined that the person has submitted the false certification.

APPLICANT:____________________________________________________

Name of Applicant By:____________________________________________

Title:_______________________________________________________

Date:______________________________________________________

STATE OF____________________________________ COUNTY OF ______________________

This instrument was acknowledged before me on the___________day of, ___________2019.

By________________________________, Notary Public

________________________________(County),__________________________(State)

My Commission Expires:_________________________________

Acting in the County of __________________________________

File details come from the government source that posted it. Updated .