Commercial Equipment Installation Rights RFR - Business Response Workbook (reopened).xlsx

XLSX spreadsheet 43 KB Posted

Attached to
For ASB Land Mobile Microwave Radio Communication Equipment Site and Tower Install Right 24-00666
Solicitation number
BD-24-1060-ITD00-ITD00-97302
Issued by
Berkshire County, Massachusetts

About this file

This document is a Request for Response (RFR) issued by the Commonwealth of Massachusetts for the Commercial Equipment Installation Rights RFR - Business Response Workbook (reopened). The RFR is seeking bids from communications equipment site providers to manage 30 different communication site locations across Massachusetts and New England. Bidders are required to complete a company profile, list available towers, and submit bids for specific communication sites within designated search areas. The RFR provides details on the required tower needs, microwave requirements, ground space, electricity, and other site specifications. Bidders that successfully complete Part 1 of the RFR will be eligible to enter into agreements with the Commonwealth for the sites listed in Part 2. The RFR includes updated and new sites, with some sites being removed. Bidders are asked to check if they operate towers within the modified or new search areas.

The RFR specifies pricing and lease terms, with the Commonwealth seeking a $0 lease contract from bidders. The RFR is part of a larger state and local contract opportunity for ASB Land Mobile Microwave Radio Communication Equipment Site and Tower Install Rights. The contract is open to bidders across Massachusetts, with the Commonwealth of Massachusetts serving as the lead agency. The RFR provides details on funding requirements, sources, and amounts, as well as any set-asides or incumbent information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Complete Company Profile

RFR Part 1: Register to Become an EOTSS-Approved, Communications Equipment Site Provider
Complete your company profile.
Complete the following information about your company. Sample responses are include below. Completing this page is a requirement to be awarded agreements under RFR Part 1.
Company InformationExampleBidder ResponseInstructions to Bidders
Company NameTowers R Us LLC (aka TowersRUs)This is the legal name for the company. Also include any alternate names for the business.
Business Address123 Main StreetThis is the primary physical address for the company's main office.
Business Address CityBoston
Business Address StateMA
Business Address Zip02109
Mail To NameATTN: Tower ServicesThis is the address that correspondence should be directed.
Mailing Address123 Main Street
Mailing Address CityBoston
Mailing Address StateMA
Mailing Address Zip02109

Business Web Site: www.towersus.com This is the URL for the Bidder.

Contact NameShiloh BarkerThis is the primary contact person for questions regarding this Bid.
Contact TitleVice President for Communicaiton Services
Contact Phone617.555.1234
Contact Emailsbarker@towersrus.com

Number of Communications Sites in Massachusetts: 3 Count multiple towers at the same physical location as one site.

Number of Communications Sites in New England: 5 Count multiple towers at the same physical location as one site.

Company Profile: Towers R Us is a multi-member limited liability corporation founded in 2003 to manage commercial communications towers at three ski locations in Massachusetts. Towers R Us is a subsidiary of Ski Massachusetts, Inc. The company focuses on site and equipment management. It provides tower services to two telephone carriers, a utility company, and several public safety organizations. The company is overseen by a board that meets quarterly. All new agreements are subject to board approval. Provide a description of the company. Include an overview of all business areas for the company, including those unrelated to communications tower services. Explain any related corporate structures (subsidiaries or parent companies).

Year of Incorporation or Business Founding: 2003 This is the year the current company was founded.

Related Services Provided by Company: The company offers the following services to communications tenants:

* Tower climbs

* Tower maintenance and inspections

* Site security monitoring

* Site maintenance

* Access road maintenance

* Managed equipment shelters List out general services provided or offered to communications equipment tenants at your various sites.

Statement of Financial Condition: Towers R Us LLC and Ski Massachusetts, Inc. are both in strong financial condition. See attached 2020 and 2021 financial reports. Explain the current financial condition of your organization. Attach financial reports as appropriate.

Describe any Current or Substantial Litigation or Contract Defaults Towers R Us LLC is not involved in any current ligitation and has not been involved in any ligitation relevant to this RFR. Towers R Us LLC has never defaulted on any related contracts. Explain any litigation or contract defaults relevant to the types of services being proposed.

Confirm Eligibility (state not debarred, suspended, or otherwise ineligible for contract award) Towers R Us LLC is eligible to bid on this procurement. Explain any orders or pending adjudications that may make disqualify the Bidder from entering into a contract under this RFR.

Copy of Liability Insurance Attached: See attached copy of liability insurance (dated December 12, 2021). Attach a current copy of your company's liability insurance.

mailto:sbarker@towersrus.comhttp://www.towersus.com/ List All Towers

RFR Part 1: Register to Become an EOTSS-Approved, Communications Equipment Site Provider
List your available communications towers.
Complete the following information about each tower location you maintain in Massachusetts. Add additional columns as needed. Sample responses are include below.
Completing this page or providing an alternate format with comparable information is a requirement to be awarded agreements under RFR Part 1.
Tower InformationExample 1Example 2Tower 1Tower 2Tower 3Tower 4Tower 5Tower 6Tower 7Tower 8
Tower Site NameScituate - Main StreetMt WashingtonThis is the primary physical address for the company's main office.
Bidder Tracking No.Tower 12Tower 4cThis is the number the Bidder uses to uniquely identify this site.
FCC Registration No.10012341049875This is the FCC registration number for the tower.
FAA Study No.2018-ANE-7991-OE2017-ANE-9669-OEThis is the FAA study number for the tower.
Tower Location (City/Town)Scituate, MAMt. Washington, MAThis is the city or town where the tower is physically located.
Tower Location (Access Road Entrance Address)123 Main StreetRt. 344 East (mile marker 12.2)This is the address for the access road to the tower.
Tower Location (Coordinates)42.12625966327241, -70.7717334645432542.11209267881872, -73.47122914643381This is the latitude and longitude of the tower.
Tower Construction Year20042016This is the original tower construction date. Note any major renovation dates.
Tower TypeGuyedMonopoleThis is the type of tower (Guyed, Self-Sustaining, Monopole, Roof Top, etc.)
Tower Height175180This is the height from ground level to the top of the tower.
Tower Owned by Bidder (Y/N), explain if NYYThis is an indicator of whether the Bidder owns the tower.
Shelter Owned by Bidder (Y/N/NA), explain if N. NA if no shelter.YNA, no managed shelterThis is an indicator of whether the Bidder owns at least one electronics shelter on site.
Land Owned by Bidder (Y/N), explain if NYYThis is an indicator of whether the Bidder owns the land where the tower is located.
Tower Space Available? (Y/N)NYThis is an indicator that the tower is not fully loaded. "Y" indicates space is available on the tower.
Shelter Space (3 racks) Available? (Y/N)NNThis is an indicator that space for 3 racks of equipment is available in a managed shelter.
Ground Space Available for new 12 x 26 shelter? (Y/N)N (see note below)YThis is an indicator that there is sufficient ground space in the vicinity of the tower for a 12 x 26 shelter.
Electical Utilities Connected? (Y/N)YYThis is an indicator if electrical utilities are already connected on site.
Phone Utilities Connected? (Y/N)NYThis is an indicator if landline phone services are already connected on site.
Fiber Backhaul Available? (Y/N)YNThis is an indicator if the site has a preexisting fiber connection for backhaul.

Site Notes Ground space could be available if existing shelter demolished. Limited access in winter. These are important notes related to the site.

Bid Sites

RFR Part 2: Submit Bids for Communications Sites in Designated Search Areas
Bid sites that meet RFR requirements for LMR and microwave communications.
1) Complete the following information for communications sites that meet EOTSS requirements. Indicate for each targeted site whether your company manages a suitable tower in the designated geographic area.
2) Sample responses are include below. Only Bidders that successfully complete RFR Part 1 of the RFR will be able to enter into agreements with the Commonwealth for the RFR Part 2 sites listed below.
3) Bids submitted by Apparent Successful Bidders in response to prior iterations of this RFR remain valid. Bidders need not resubmit site information, if that information has previously been submitted a part of complete bid. Bidders may resubmit tower information or add additional towers to sites being rebid under this RFR.
4) Please note where highlighted when the search areas for existing sites have been modified. Bidders are asked to check whether or not they operate communications sites within the modified search ring. These sites are marked with yellow highlighting.
5) Please note additional sites have been added to this procurement. Bidders are asked to check whether or not they operate communications sites within these new rings. These new sites are marked with green highlighting.
6) Bidders that operate more than one tower within the search area for a particular site can list each individual tower/site in the two sections below (listed "Bidder Response" and "Bidder Response 2nd Site"). This new section is marked with orange highlighting.
REMOVED: Replaced by Site 22.In lease negotiations. Bidders may still submit bids on this site.REMOVED: Replaced by Site 24.REMOVED: Replaced by Site 19.REMOVED: Replaced by Site 26.REMOVED: Replaced by Site 25.UPDATED: Modified search area. Check if tower sites in new ring.UPDATED: Modified search area. Check if tower sites in new ring.UPDATED: Modified search area. Check if tower sites in new ring.UPDATED: Modified search area. Check if tower sites in new ring.UPDATED: Modified search area. Check if tower sites in new ring.NEW SITE: Check if tower sites in new ring.NEW SITE: Check if tower sites in new ring.NEW SITE: Check if tower sites in new ring.
Requested SitesExample 1Example 2Site 1Site 2Site 3Site 4Site 5Site 6Site 7Site 8Site 9Site 10Site 11Site 12Site 13Site 14Site 15Site 16Site 17Site 18Site 19Site 20Site 21Site 22Site 23Site 24Site 25Site 26Site 27Site 28Site 29Site 30Site 31Site 32Site 33Site 34Site 35
Site Location (Town or Region)Adams, MALenox, MAAmesbury, MAFalmouth, MAFalmouth, MAGloucester, MANashua, NHNew Bedford, MANew Salem, MAPelham, MAQuincy, MARowley, MASaugus, MATolland, MAHolland, MAWoburn, MAMilford, MAAttleboro, MAHaverhill, MABournedale, MAWoburn, MAScituate, MABarnstable, MANew Bedford, MAPlymouth, MARowley, MAHaverhill, MAAttleboro, MARehoboth, MACumberland, RIYarmouth, MANorth Andover, MAMendon, MAMonson, MAWrentham, MAWaltham, MAOxford, MA
Centerpoint of Search Area42.635,-73.16542.392,-73.31142.865,-70.93941.654,-70.60241.55,-70.6142.601,-70.7442.723,-71.46141.642, -70.92842.48, -72.3742.36, -72.4242.24, -71.0042.710, -70.92542.4532,-71.036642.13, -73.1242.06,-72.2042.433,-71.17342.14, -71.5241.93,-71.3342.79,-71.0841.774 -70.57042.45, -71.1842.192 -70.82141.686 -70.34741.642, -70.92841.925, -70.5942.705, -70.90642.80, -71.0741.94, -71.3141.83, -71.2341.993, -71.44741.69, -70.18942.665, -71.10542.06, -71.5742.12, -72.3542.06, -71.2942.390, -71.25542.10, -71.82
Centerpoint on Google Mapshttp://maps.google.com/maps?q=42.635,-73.165http://maps.google.com/maps?q=42.392,-73.311http://maps.google.com/maps?q=42.865,-70.939http://maps.google.com/maps?q= 41.654,-70.602http://maps.google.com/maps?q=41.55,-70.61http://maps.google.com/maps?q=42.601,-70.74http://maps.google.com/maps?q=42.723,-71.461http://maps.google.com/maps?q=41.642, -70.928http://maps.google.com/maps?q= 42.48, -72.37http://maps.google.com/maps?q=42.36, -72.42http://maps.google.com/maps?q= 42.24, -71.00http://maps.google.com/maps?q= 42.710, -70.925http://maps.google.com/maps?q=42.4532,-71.0366http://maps.google.com/maps?q= 42.13, -73.12http://maps.google.com/maps?q=42.06,-72.20http://maps.google.com/maps?q=42.433,-71.173http://maps.google.com/maps?q=42.14, -71.52http://maps.google.com/maps?q=41.93,-71.33http://maps.google.com/maps?q=42.79,-71.08http://maps.google.com/maps?q= 41.774 -70.570http://maps.google.com/maps?q=42.45,-71.18http://maps.google.com/maps?q= 42.192 -70.821http://maps.google.com/maps?q= 41.686 -70.347http://maps.google.com/maps?q=41.642, -70.928http://maps.google.com/maps?q=41.925, -70.59http://maps.google.com/maps?q=42.705, -70.906http://maps.google.com/maps?q=42.80, -71.07http://maps.google.com/maps?q=41.94, -71.31http://maps.google.com/maps?q=41.83, -71.23http://maps.google.com/maps?q=41.993, -71.447http://maps.google.com/maps?q=41.69, -70.189http://maps.google.com/maps?q=42.665, -71.105http://maps.google.com/maps?q=42.06,-71.57http://maps.google.com/maps?q=42.12,-72.35http://maps.google.com/maps?q=42.06,-71.29http://maps.google.com/maps?q=42.390,-71.255http://maps.google.com/maps?q=42.10,-71.82
Radius of Search Area0.5 mile0.5 mile0.5 mile1.0 mile1.5 mile1.5 mile0.5 mile1.75 mile3.0 mile3.0 mile3.0 mile2.0 mile0.5 mile5.0 mile5.0 mile2.0 mile2.5 mile4.0 mile2.0 mile0.25 miles2.5 miles0.5 miles1.0 miles1.8 miles1.0 miles1.0 miles1.0 miles1.0 miles2.5 miles1.0 miles2.5 miles2.0 miles1.0 mile2.0 miles0.25 mile1.25 mile2.0 miles
Tower Needs (RF Antennas)Space for 2 RF sticks and/or RF 2-4 panel antennasSpace for 2 RF sticks and/or RF 2-4 panel antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 RF sticksSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 RF sticksSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 RF sticksN/ASpace for 3 RF sticksSpace for 3 RF sticksSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennasSpace for 3 10' omnidirectional whip antennas
Preferred Elevation on Tower (RF Antennas)above treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineN/Aabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treeline and nearby buildingsabove treelineabove treeline and nearby buildingsabove treelineabove treeline and nearby buildingsabove treelineabove treelineabove treeline and nearby buildingsabove treelineabove treelineabove treelineabove treelineabove treelineabove treeline
Tower Needs (Microwave)4 6' MW dishes2 8' MW dishesSpace for 2 microwave dishesSpace for 2 microwave dishesSpace for 3 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishes1-6' dish, 1-4' dishSpace for 2 microwave dishesSpace for 3 microwave dishesSpace for 2 microwave dishes2-6' dishesSpace for 2 microwave dishesSpace for 2 microwave dishesSpace for 1 microwave dish1-4' dish, 1-6' dishSpace for 2 microwave dishes2-6' dishes1-3' dish, 1-6' dishSpace for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishesSpace for 2 microwave dishes2-3 microwave dishesSpace for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)Space for 2 microwave dishes (for planning assume 1 3ft dish and 1 6ft dish)
Preferred Elevation on Tower (Microwave)Minimum 30' or above treelineMinimum 40' or above treelineabove treelineN/Aabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineN/Aabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treelineabove treeline
Line Type (Microwave)Waveguide; 100 1/2" & 7/8" coaxWaveguide; 100 1/2" & 7/8" coaxElliptical WaveguideN/AElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideN/AElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical WaveguideElliptical Waveguide
Ground Space Needs12' x 26' shelter + 5' x 15' pad for tanks12' x 26' shelter + 5' x 15' pad for tanks12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12' x 20' shelter + 35 Keva generator+5' x 15' pad for tanks12'x16' shelter plus pad for generator12'x16' shelter plus pad for generatorPrivate shelter space with HVAC, generator power, and space to install 6 equipment racks or ground space to install a 12'x16' shelter plus pad for generator and LP tank.12' x 20' shelter + 35 Kva generator+5' x 15' pad for tanks12'x16' shelter plus pad for generator12'x16' shelter plus pad for generator12'x16' shelter plus pad for generator12' x 20' shelter + 35 Kva generator+5' x 15' pad for tanks12'x16' shelter plus pad for generator12' x 26' shelter with interior 35 Kva generator+ 5' x 15' pad for tankspace in managed shelter, new 35 Kva generator+5'x15' pad for tanks12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racksPrivate shelter space with HVAC, generator power, and space to install 6 equipment racks or ground space to install a 12'x16' shelter plus pad for generator and LP tank.12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator and LP tank or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator and LP tank or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator and LP tank12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks12'x16' shelter plus pad for generator or private shelter space with HVAC, generator power, and space to install 6 equipment racks
Electricity Needsminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phaseminimum 200 amp single phase
Originally Requested Date3/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/223/1/222/1/2023 (updated 1/26/2024)2/1/2023 (updated 1/26/2024)2/1/232/1/232/1/2023 (updated 1/26/2024)2/1/232/1/232/1/232/1/232/1/232/1/232/1/232/1/232/1/2023 (updated 1/26/2024)8/18/2023 (updated 1/26/2024)1/26/241/26/241/26/24
Bidder ResponseExample 1Example 2Site 1 Amesbury, MASite 2 Falmouth, MASite 3 Falmouth, MASite 4 Gloucester, MASite 5 Nashua, NHSite 6 New Bedford, MASite 7 New Salem, MASite 8 Pelham, MASite 9 Quincy, MASite 10 Rowley, MASite 11 Saugus, MASite 12 Tolland, MASite 13 Holland, MASite 14 Woburn, MASite 15 Milford, MASite 16 Attleboro, MASite 17 Haverhill, MASite 18 Bournedale, MASite 19 Woburn, MASite 20 Scituate, MASite 21 Barnstable, MASite 22 New Bedford, MASite 23 Plymouth, MASite 24 Rowley, MASite 25 Haverhill, MASite 26 Attleboro, MASite 27 Rehoboth, MASite 28 Cumberland, RISite 29 Yarmouth, MASite 30 North Andover, MASite 31 Mendon, MASite 32 Monson, MASite 33 Wrentham, MASite 34 Waltham, MASite 35 Oxford, MA
Bidder has tower at designated region? (Y/N)NYDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRThis is an indicator of whether or not the Bidder has a suitable communications site in the geographic area.
Bidder's Tower NameTowers R Us Tower 124 (Lennox)This is the Bidder's name for its proposed site.
Tower Coordinates42.393236075997144, -73.31073178038973This is the coordinates for proposed tower.
FCC Registration No.1012255This is the FCC Registration No. for the proposed tower.
FAA Study No.2019-ANE-2456-OEThis is the FAA Study No. for the proposed site.
Tower Sufficient Available Space and Loading? (Y/N)YThis is an indicator of whether there is sufficient tower space and loading capacity available for the specified RF and microwave equipment.
Antenna centerlines available50', 70' ,100-130', 170'These are the available centerlines for communications equipment on the proposed tower.
Sufficient Shelter Space Available (Y/N)? Describe.N, No managed shelter.This is an indicator of whether or not a managed shelter is available.
Sufficient Ground Space Available (Y/N)? Describe.Y, 30' by 24' area available within security fencingThis is an indicator of whether or not sufficient ground space is available.
Adequate Electricity Available (Y/N)? List utility.Y, EversourceThis is an indicator of whether electrical utilities are connected to the site. Include the name of the utility provider.
Fiber backhaul carriers with existing connections to site (Y/N). List carrier.Y, Comcast CableThis is an indicator of whether fiber backhaul is available at the site. Include the name of the backhaul provider.
Bidder willing to offer a ($0) lease contract? (Y/N) If "No", attach pricing sheet. Include file name.Y, see proposed pricing (Towers R Us pricing sheet.docx)This is an indicator if the Bidder is willing to offer a $0 lease contract. If not, the Bidder should detail how services at this site are priced.
Indicate whether site photos attached (Y/N). Include file name.Y, see photos (Tower123.docx)This is an indicator of whether or not photos of the site are submitted. Include file name for photos.
Indicate whether site layout and tower diagrams attached (Y/N). Include file name.Y, see site diagrams (Tower123.docx)This is an indicator of whether or not diagrams of the site and tower are submitted. Include file name.
Indicate whether site agreement attached (Y/N). Include file name.Y, see proposed site agreement (Towers R Us site agreement.docx)This is an indicator of whether or not proposed site agreement is submitted. Include file name for site agreement.
Use only if 2nd sites in search ring.
Bidder Response 2nd SiteExample 1Example 2Site 1-B Amesbury, MASite 2-B Falmouth, MASite 3-B Falmouth, MASite 4-B Gloucester, MASite 5-B Nashua, NHSite 6-B New Bedford, MASite 7-B New Salem, MASite 8-B Pelham, MASite 9-B Quincy, MASite 10-B Rowley, MASite 11-B Saugus, MASite 12-B Tolland, MASite 13-B Holland, MASite 14-B Woburn, MASite 15-B Milford, MASite 16-B Attleboro, MASite 17-B Haverhill, MASite 18-B Bournedale, MASite 19-B Woburn, MASite 20-B Scituate, MASite 21-B Barnstable, MASite 22-B New Bedford, MASite 23-B Plymouth, MASite 24-B Rowley, MASite 25-B Haverhill, MASite 26-B Attleboro, MASite 27-B Rehoboth, MASite 28-B Cumberland, RISite 29-B Yarmouth, MASite 30-B North Andover, MASite 31-B Mendon, MASite 32-B Monson, MASite 33-B Wrentham, MASite 34-B Waltham, MASite 35-B Oxford, MAOnly use this section if you are proposing a second communication site within the search ring for this site.
Bidder has tower at designated region? (Y/N)NYDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRDO NOT BID -- SITE REMOVED FROM RFRThis is an indicator of whether or not the Bidder has a suitable communications site in the geographic area.
Bidder's Tower NameTowers R Us Tower 124 (Lennox)This is the Bidder's name for its proposed site.
Tower Coordinates42.393236075997144, -73.31073178038973This is the coordinates for proposed tower.
FCC Registration No.1012255This is the FCC Registration No. for the proposed tower.
FAA Study No.2019-ANE-2456-OEThis is the FAA Study No. for the proposed site.
Tower Sufficient Available Space and Loading? (Y/N)YThis is an indicator of whether there is sufficient tower space and loading capacity available for the specified RF and microwave equipment.
Antenna centerlines available50', 70' ,100-130', 170'These are the available centerlines for communications equipment on the proposed tower.
Sufficient Shelter Space Available (Y/N)? Describe.N, No managed shelter.This is an indicator of whether or not a managed shelter is available.
Sufficient Ground Space Available (Y/N)? Describe.Y, 30' by 24' area available within security fencingThis is an indicator of whether or not sufficient ground space is available.
Adequate Electricity Available (Y/N)? List utility.Y, EversourceThis is an indicator of whether electrical utilities are connected to the site. Include the name of the utility provider.
Fiber backhaul carriers with existing connections to site (Y/N). List carrier.Y, Comcast CableThis is an indicator of whether fiber backhaul is available at the site. Include the name of the backhaul provider.
Bidder willing to offer a ($0) lease contract? (Y/N) If "No", attach pricing sheet. Include file name.Y, see proposed pricing (Towers R Us pricing sheet.docx)This is an indicator if the Bidder is willing to offer a $0 lease contract. If not, the Bidder should detail how services at this site are priced.
Indicate whether site photos attached (Y/N). Include file name.Y, see photos (Tower123.docx)This is an indicator of whether or not photos of the site are submitted. Include file name for photos.
Indicate whether site layout and tower diagrams attached (Y/N). Include file name.Y, see site diagrams (Tower123.docx)This is an indicator of whether or not diagrams of the site and tower are submitted. Include file name.
Indicate whether site agreement attached (Y/N). Include file name.Y, see proposed site agreement (Towers R Us site agreement.docx)This is an indicator of whether or not proposed site agreement is submitted. Include file name for site agreement.

http://maps.google.com/maps?q=%2041.774%20-70.570http://maps.google.com/maps?q=42.390,-71.255http://maps.google.com/maps?q=42.45,-71.18http://maps.google.com/maps?q=%2042.192%20-70.821http://maps.google.com/maps?q=%2041.686%20-70.347http://maps.google.com/maps?q=42.665,%20-71.105http://maps.google.com/maps?q=42.12,-72.35http://maps.google.com/maps?q=42.10,-71.82http://maps.google.com/maps?q=42.06,-71.29http://maps.google.com/maps?q=42.06,-71.57