Chiller Inventory and Legen Chiller System.xlsx
XLSX spreadsheet 492 KB Posted
- Solicitation number
- 36C26124Q0959
About this file
This document appears to be a spreadsheet detailing the inventory and maintenance information for a series of chiller and cooling tower systems located at a facility. The spreadsheet provides details on the specific equipment such as manufacturer, model, serial number, and service requirements per ASHRAE 180-2018 standards.
The related federal contract opportunity is for the maintenance and repair of these chillers and cooling towers. The solicitation number is 36C26124Q0959 and the contract is being issued by the Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 21. The contract requires maintaining and repairing the chiller and cooling tower systems described in the inventory spreadsheet.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 Amendment 0001 09-03-24.pdf | ||
| S02 36C26124Q0959.pdf | ||
| 36C26124Q0959_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Chillers and Cooling Towers
| Location Details | System | Equipment Details | Service Intervals | |||||||
| System | Site | Bldg No. | Type (see codes) | MFG | Model | Serial Number | Notes | Q-Inspections (See ASHRAE 180-2018) | SA-Inspections (See ASHRAE 180-2018) | A-Inspections (See ASHRAE 180-2018) |
| 1 | Stockton | 915 | B | York # 1 | YKG9E9P8-ETHX | SHJM-852720 | CUP MODEL YK (Style H) centrifugal liquid chiller ) | Quarterly (2 each) | Semi-Annual (1ea) | Annual (1ea) |
| Stockton | 915 | Baltimore air coil company | XES3E-1222-140-3 | U202647207-01-01 | CT1 | |||||
| 2 | Stockton | 915 | B | York # 2 | YKG9E9P8-ETHX | SHJM-852920 | CUP MODEL YK (Style H) centrifugal liquid chiller ) | Quarterly (2 each) | Semi-Annual (1ea) | Annual (1ea) |
| Stockton | 915 | Baltimore air coil company | XES3E-1222-140-3 | U202647207-01-02 | CT2 | |||||
| 3 | Stockton | 915 | B | York # 3 | YKG9E9P8-ETHX | SHJM-853120 | CUP MODEL YK (Style H) centrifugal liquid chiller ) | Quarterly (2 each) | Semi-Annual (1ea) | Annual (1ea) |
| Stockton | 915 | Baltimore air coil company | XES3E-1222-140-3 | U202647207-01-03 | CT3 |
&18&D &T
&"-,Bold"&14Page &P of &N
Legend-Chiller Systems
| HVAC Chilled Water System | |
| Chiller Loop with an Open Loop Tower System "A" | Chiller Loop with an Open Loop Tower System "B" |
| Description: Open Loop Condenser Water, Closed Loop Chilled Water, Maintain Cooling Tower Water (Subject to VHA 1061 Bi-Weekly Dip Slide or HPC) | Description: Closed Loop Condenser Water, Closed Loop Chilled Water, Maintain Cooling Tower Water (Subject to VHA 1061 Bi-Weekly Dip Slide or HPC) |
| Chiller Loop with Cooling Tower / Heat Exchanger Combination System "C" | Chiller Loop with a DX Condensing Circuit System "D" |
| Descriptoin: Open Loop Condensing Water, Closed loop heat exchanger, Closed Loop Chilled Water | Description: Closed Loop DX Condenser, Closed Loop Chilled Water |
| Chiller with Condenser Refrigerant Loop Disapaiting Heat in Cooling Tower Sump Water "E" | Chiller Loop with a DX Condensing & Evaporator Circuit "F" |
| Descriptoin: Open Loop Condensing Water, Closed loop heat exchanger, Closed Loop Chilled Water | Description: Closed Loop DX Condenser, Closed Loop Chilled Water |
| Example of a Common Header Systems |
| Common Header Systems |