Changes_Fed Std 833P Items 359W-363W Medium Duty Shuttle Bus.docx

DOCX document 220 KB Posted

Attached to
Main Bus Program 2020 Federal contract opportunity
Solicitation number
AMENDMENT_2
Issued by
GSA Federal Acquisition Service

About this file

This is Amendment 2 to a solicitation issued by the General Services Administration Federal Acquisition Service. It includes updates to Federal Standard 833P requirements and additions of FAR clauses 52.204-24 and 52.204-25. Buses must meet specifications in Federal Standard 833P for various configurations seating 28-36 adults and widths of 94-102 inches. The amendment is in response to Solicitation 47QMCA20R0002 for the Main Bus Program 2020 and potential bidders should return only the SF30 cover page with blocks 14, 15A, 15B, and 15C completed.

View the file

Other files for this federal contract opportunity

Other files attached to Main Bus Program 2020, newest first.
File Type Posted
Changes_Fed Std 833P Items 301C-304C Type A School Bus.docx DOCX document
Changes_Fed Std 833P Item 398 Heavy Duty Over the Road Touring Coach.docx DOCX document
Changes_833P Bus Options Appendix A Specifications.docx DOCX document
Fed Std 833P Items 341N-347 Light Duty Shuttle Bus.pdf PDF
Fed Std 833P Items 396-397 Heavy Duty Intercity Commuter Coach.pdf PDF
Fed Std 833P Items 301C-304C Type A School Bus.pdf PDF
Fed Std 833P Item 202C Type A School Bus Basic.pdf PDF
Changes_Fed Std 833P Items 241N-247 Light Duty Shuttle Basic.docx DOCX document
Changes_Fed Std 833P Items 396-397 Heavy Duty Intercity Commuter Coach.doc DOC document
Changes_Fed Std 833P Items 240L Light Duty Shuttle Low-Floor.docx DOCX document
Fed Std 833P Item 398 Heavy Duty Over the Road Touring Coach.pdf PDF
Fed Std 833P Items 240L Light Duty Shuttle Low-Floor.pdf PDF
Changes_Fed Std 833P Item 202C Type A School Bus Basic.docx DOCX document
47QMCA20R0002 Amendment 2.pdf PDF
833P Bus Options Appendix A Specifications.pdf PDF
Changes_Fed Std 833P Items 341N-347 Light Duty Shuttle Bus.docx DOCX document
Fed Std 833P Items 241N-247 Light Duty Shuttle Basic.pdf PDF
Fed Std 833P Items 359W-363W Medium Duty Shuttle Bus.pdf PDF
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U.S. General Services Administration

Fed Std 833P Items 359W-363W Medium Duty Shuttle Bus 1

Federal Standard 833P

MEDIUM-DUTY SHUTTLE BUS

STANDARD ITEM NUMBERS:

359W, 360, 360W, 360L, 363, 363W

May 22July 27, 2020

Fed Std 833P Items 359W-363W Medium Duty Shuttle Bus 3

TABLE OF CONTENTS

Fed Std 833P Items 359W-363W Medium Duty Shuttle Bus

Note: You may click on a heading to automatically scroll there

1. SCOPE, PURPOSE, & CLASSIFICATION3
2. APPLICABLE DOCUMENTS4
3. REQUIREMENTS5
3.1BODY & CHASSIS5
3.2AIR POLLUTION CONTROL7
3.3ENGINES7
3.4ENGINE ACCESSORIES8
3.5TRANSMISSION8
3.6BRAKES8
3.7AXLES9
3.8ELECTRICAL10
3.9FUEL11
3.10EXTERIOR11
3.11DOORS AND WINDOWS12
3.12LIGHTS AND LIGHTING13
3.13ELECTRONICS/AUDIO VISUAL14
3.14INTERIOR14
3.15FLOOR16
3.16WALLS16
3.18SEATS17
3.19SAFETY17
3.20SUSPENSION18
3.21TIRES AND WHEELS18
3.22MISCELLANEOUS19
3.26GENERAL WORKMANSHIP REJECTION STANDARDS19
3.27IDENTIFICATION OF VEHICLES20
3.28CERTIFICATE OF ORIGIN OR BILL OF SALE20
3.29WARRANTY REQUIREMENTS20
3.30EXCEPTIONS TO WARRANTY21
3.31DETECTION OF DEFECTS21
3.32SCOPE OF WARRANTY REPAIRS21
3.33FLEET DEFECTS21
3.34INTENDED USE21
3.35REPAIR PARTS AND SERVICE21
3.36DOMESTIC USE22
3.37FOREIGN USE22
4.1VERIFICATION23
4.2FIRST PRODUCTION VEHICLE INSPECTION23
4.3INSPECTION OF PRODUCTION VEHICLES23
5. NOTES24
5.1ORDERING DATA24
5.2DEVIATION FROM FEDERAL STANDARD24
5.3CHANGES AND NOTICES24
1. SCOPE, PURPOSE, & CLASSIFICATION3
2. APPLICABLE DOCUMENTS4
3. REQUIREMENTS5
3.1BODY & CHASSIS5
3.2AIR POLLUTION CONTROL7
3.3ENGINES7
3.4ENGINE ACCESSORIES8
3.5TRANSMISSION8
3.6BRAKES8
3.7AXLES9
3.8ELECTRICAL10
3.9FUEL11
3.10EXTERIOR11
3.11DOORS AND WINDOWS12
3.12LIGHTS AND LIGHTING13
3.13ELECTRONICS/AUDIO VISUAL14
3.14INTERIOR14
3.15FLOOR16
3.16WALLS16
3.18SEATS17
3.19SAFETY17
3.20SUSPENSION18
3.21TIRES AND WHEELS18
3.22MISCELLANEOUS19
3.26GENERAL WORKMANSHIP REJECTION STANDARDS19
3.27IDENTIFICATION OF VEHICLES20
3.28CERTIFICATE OF ORIGIN OR BILL OF SALE20
3.29WARRANTY REQUIREMENTS20
3.30EXCEPTIONS TO WARRANTY20
3.31DETECTION OF DEFECTS21
3.32SCOPE OF WARRANTY REPAIRS21
3.33FLEET DEFECTS21
3.34INTENDED USE21
3.35REPAIR PARTS AND SERVICE21
3.36DOMESTIC USE22
3.37FOREIGN USE22
4.1VERIFICATION23
4.2FIRST PRODUCTION VEHICLE INSPECTION23
4.3INSPECTION OF PRODUCTION VEHICLES23
5. NOTES24
5.1ORDERING DATA24
5.2DEVIATION FROM FEDERAL STANDARD24
5.3CHANGES AND NOTICES24

Fed Std 833P Items 359W-363W Medium Duty Shuttle Bus 195

1. SCOPE, PURPOSE, & CLASSIFICATION

1.0 SCOPE

This Standard covers commercial medium-duty, shuttle buses.

The buses specified herein are of metal body on safety cage construction mounted on cutaway type or full cab, rear-wheel drive truck chassis with a minimum GVWR of 21,000 lbs.

This Standard is intended to simplify competitive procurement of commercial vehicles and achieve a practical degree of standardization within the federal fleet.

The Government takes no exemptions to the laws and regulations for vehicles used on public roads and highways.

1.2 APPLICATION

This Standard does not include all varieties of the commodity indicated by the title but is intended to cover those vehicles generally acquired by the Government. Buses with standardized components and equipment are highlighted in this Standard. A selection of coded optional additional systems and equipment are included for agencies, divergent geographic and operational related needs.

1.3 COVERAGE OF BUS TYPES

The types of buses covered by this standard are listed below. Optional equipment appears in section Appendix A and beneath each relevant section in the requirements.

The item descriptions, minimums, options, and manufacturer data can be viewed on this website: www.gsa.gov/automotive. Click on the link for all standards and refer to Federal Standard 833.

1.4 CLASSIFICATIONS

- The individual bus configuration classifications are referred to by a Standard Item Number (SIN)

- The SINs covered by this specification are as follows:

· 359W - 28 Adult, 100-102 Inch Wide, Medium-Duty Shuttle Bus

· 360 – 32 Adult, 94-99 Inch Wide, Medium-Duty Shuttle Bus

· 360W – 32 Adult, 100-102 Inch Wide, Medium-Duty Shuttle Bus

· 360L - 32 Adult, 100-102 Inch Wide, Low-Floor, Medium-Duty Shuttle

· 363 - 36 Adult, 94-99 Inch Wide, Medium Duty Shuttle Bus

· 363W – 36 Adult, 100-102 Inch Wide, Medium-Duty Shuttle Bus

2. APPLICABLE DOCUMENTS

2.1 FEDERAL SPECIFICATION

2.1.1 ADA Transportation Vehicle Accessibility Guidelines (ADA) 36 CFR Part 1192
2.1.2 Federal Motor Vehicle Safety Standards (FMVSS) 49 CFR Part 571
2.1.3 Federal Motor Carrier Safety Regulations (FMCSR) 49 CFR Part 393
2.1.4 A-A-393A Commercial Item Description Extinguishers, Fire, Dry-Chemical

2.2 NON-GOVERNMENT STANDARDS

2.2.1 Society of Automotive Engineers (SAE) Standards and Recommended Practices

- J163 Low Tension Wiring and Cable Terminals and Splice Clips
- J198 Windshield Wiper Systems- Trucks, Buses, and Multipurpose Vehicles
- J381 Windshield Defrosting Systems Test Procedure and Performance Requirements
- J551 Performance Levels and Methods of Measurement of Electromagnetic Compatibility of Vehicles
- J516 Hydraulic Hose Fittings
- J537 Storage Batteries
- J561 Electrical Terminals-Eyelets and Spade Type
- J588 Turn Signal Lamps for Use on Motor Vehicles Less than 2032 mm in Overall Width
- J589 Turn Signal Switch
- J673 Automotive Safety Glasses
- J686 Motor Vehicle License Plates
- J695 Turning Ability and Off Tracking-Motor Vehicles
- J844 Nonmetallic Air Brake System Tubing
- J910 Hazard Warning Signal Switch
- J1127 Battery Cable
- J1128 Low Tension Primary Cable
- J1149 Metallic Air Brake System Tubing and Pipe
- J1292 Automobile, Truck, Truck-Tractor, Trailer, and Motor Coach Wiring
- J1908 Electrical Grounding Practice
- J2064 R134a Refrigerant Automotive Air-Conditioning Hose
- J2188 Commercial Truck and Bus SAE Recommended Procedure for Vehicle Performance Prediction

2.2.2 American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE)

- A03 Handbook, Chapter 9, Surface Transportation
- 37 Standard Methods of Testing for Rating Unitary Air-Conditioning and Heat Pump Equipment
- 41.1 Standard Methods for Temperature Measurement

- 41.2 Standard Methods for Laboratory Airflow Measurement

- 41.3 Standard Method for Pressure Measurement

2.2.3 American Trucking Association, Inc.

- Technology and Maintenance Council (TMC) RP 803

2.3 ORDER OF PRECEDENCE

In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. However, nothing in this document supersedes applicable laws and regulations unless a specific exemption has been obtained

3. REQUIREMENTS

3.1 BODY & CHASSIS

3.1.1 PASSENGER CAPACITIES

Standard Item Number (SIN)

Adult Capacity (Seated)

SIN 359W

28 Adult

SIN 359L
28 Adult
SIN 360
32 Adult
SIN 360W
32 Adult
SIN 360L
32 Adult
SIN 363
36 Adult
SIN 363W
36 Adult

3.1.2 BODY CONSTRUCTION

-The buses under this specification shall be of commercial square-bow type construction, shuttle bus and is not applicable to school bus type construction.

3.1.3 BODY FASTENER APPLICATION

-All fasteners shall be corrosion resistant.

3.1.4 BODY STRUCTURE

-Body Structure shall be of safety cage design. Wood shall not be used for structural framing.

3.1.5 BODY INTEGRITY

-The body, floor, roof, and panel joints shall be water and air resistant.

-All body seams shall be sealed and not permit dust or fume entry into passenger compartment.

-Body, hinge, and, mirror mounting points shall be reinforced to prevent cracking and fastener or fastener device pull out.

3.1.6 BODY EXTERIOR LENGTHS

-Body measurement shall be exterior rear surface to front face of body. Length measurement shall include bumpers.

-Bus body lengths shall not be changed to accommodate space consuming optional equipment. Only one body length shall apply to each SIN.

3.1.7 BODY EXTERIOR WIDTH

-This measurement shall be taken from the exterior vertical body surface of the primary body skin panel.

3.1.8 BODY EXTERIOR

-Bus side outer panels shall be metal. The roof when not available as a metal surface can be of composite construction.

-Bus end caps can be of composite construction materials if not available in metallic.

-Tires shall not protrude beyond exterior body side wall.

-Composite rubber fender extensions or molded high impact plastic body accents can be used to cover tire edge.

3.1.9 RAIN SPLASH CONTROL

-Rain gutters, hoods, or lips shall be provided to prevent water from the roof flowing onto the passenger doors, side windows, and the door boarding area.

3.1.10 PASSENGER COMPARTMENT INTERIOR DIMENSIONS

-Interior height should be measured from the floor to center peak of ceiling. Measurement minimum shall be maintained between the first and last vertical roof bows.

3.1.11 INSULATION

-All bus and chassis manufacturer standard and optional insulation packages shall be supplied as standard and shall comply with FMVSS 571.302.

-Buses shall have all available firewall insulation -Insulation as installed in bus shall have a minimum R-value of 5.

-When using insulation that is not spray urethane:

· The insulation material shall not be exposed to moisture including but not limited to wash downs.

· The insulation material shall not be exposed to the exterior including under bus body.

· The insulation material shall not be used in any manner for which it was not originally designed.

-Insulation shall fill all cavity areas and voids in:

· Outer and inner walls

· Outer and inner roof

· Roof bow hat section

· Front and rear caps

3.1.12 MAINTENANCE

-The design of the bus and optional equipment shall permit access for routine servicing and shall permit access for replacement and adjustment of component parts and accessories with minimal disturbance of other components and systems.

-Interior hinged and fastener-secured access panels and doors for maintenance must:

· Use common tools to open and be flush with the surrounding materials.

· Be sealed to prevent entry of fumes and water into passenger compartment.

3.1.13 SOUND LEVEL

-The interior sound level when measured in accordance with FMCSR 393.94 shall not be greater than 82db.

-This requirement shall be expanded to include any location within the passenger compartment.

-All noise reduction methods available from body and chassis manufacturer shall be added to the standard package. Examples of noise reduction methods that may be included as standard include:

· Complete lining of stepwell treads and sides with multiple layer noise reduction matting

· Urethane foam underbody insulation

· Application of PPG Audio guard acoustical coating

· Underbody shielding

· Engine compartment and under hood noise control matting.

3.1.14 BODY MOUNTING

-Cushion material shall be utilized between body and frame. Body can be floated but shall not include wooden spacer blocks.

-Reinforcements or filler blocks shall be used where mounting devices might otherwise deform frame flanges.

-Mounting devices shall utilize fasteners that will minimize loosening, but which may require regular scheduled tightening.

-Interface of chassis and body, including all electrical, fluid, mechanical systems, and mounted equipment shall be in full accordance with the chassis manufacturer’s “Body Builders Book” and published equipment technical data.

3.1.15 CORROSION PROTECTION

-All hardware shall be corrosion resistant.

-Fastener materials shall be compatible with materials being fastened.

-No bare metal permitted.

-All joints and connections of dissimilar metals shall be insulated to minimize effects of galvanic corrosion.

3.1.16 UNDERCOATING

-Underbody, fenders, skirts, and wheel-wells shall be undercoated. The exceptions to this requirement are plastic or polymer exterior parts not subject to deterioration or damage from road splash and debris.

3.1.17 MUD FLAPS

-Rubber composition mud flaps at all wheel ends shall extend to within 3 to 7 inches off the ground when suspension is at normal operating height and at curb weight.

3.1.18 CURB WEIGHT

-The curb weight shall include the weight of the chassis and body with all attachments, accessories, standard and optional equipment, a full complement of fuel, lubricants, coolants.

3.1.19 PAYLOAD AND GROSS VEHICLE WEIGHT

-The payload weight for adult passengers shall be calculated using 215 pounds per person and 215 pounds for the driver. These ratings include provisions for parcels and shall be considered an even weight distribution throughout the body.

-Wheelchair positions shall be calculated using 300 lbs. for each wheelchair position specified. When a wheelchair position includes convertible seating, the 215 pounds per seated person shall be included in the calculation instead of 300.

3.1.20 CAPACITY DECAL

-An instruction decal shall be applied to the forward bulkhead visible to all passengers and driver. The lettering shall be not less than 1-1/2 inch in height and in strong contrast to the interior background color.

-The message can be in a single line or two lines and must state “No Standees Permitted” or “No Standees” and “Maximum Passenger Capacity XX” or “Capacity XX Passengers”. The two X’s shall represent the passenger capacities specified as standard and optional.

-Multiple decals can be used to accommodate this requirement with one displaying the no standees instruction statement and another displaying passenger capacity.

3.1.21 TOWING DEVICES

-Front and rear towing devices shall be furnished.

-Front devices can be deleted if the chassis manufacturer incorporates a frame crush zone that prohibits attachment of the towing devices.

-If the bus cannot be lifted with the furnished hooks or loops without damaging body panels or the frame, a warning label shall be permanently affixed to the frame area immediately next to the towing devices and clearly visible to tow truck operator during recovery procedures.

Warning label shall be in high contrast to its surroundings to provide immediate recognition. The warning label shall read in bold letters no smaller than ¼ inch, “DO NOT LIFT BUS WITH TOW EYES. TOW EYES FOR FLAT GROUND MANEUVERING ONLY.”

-Complete towing instructions shall be furnished with the operator's manual.

-Rear towing device(s) shall not provide a toehold for unauthorized riders

3.2 AIR POLLUTION CONTROL

-The vehicle and engine shall confirm to 40 CFR Subchapter C-Part 86“Control of Emissions from New and In-use Highway Vehicles and Engines,” as evidenced by an EPA certificate of compliance.

-Vehicles shall also comply with all pollution control requirements for the State of final destination. -Certificates of compliance shall be made available upon request.

3.3 ENGINES

3.3.1 COOLING SYSTEM

-Cooling system shall be charged with extended life coolant.

-All coolant hoses and lines shall meet or exceed the requirements of SAE J20 D2.

-All hoses and lines shall be securely attached with constant-tension or thermoplastic clamps. Hoses and lines shall not be permitted to rub components that may eventually lead to a coolant leak.

-Passenger compartment heater hoses shall be equipped with full-flow valves located in a protected location to permit complete shutoff of engine coolant flow to heating units. The location of manual valves shall be indicated with a label stating the purpose of the valves such as “Heater Shutoff Valves” and located to be visibly obvious.

3.3.2 ENGINE COMPARTMENT

-Engine compartment shall be readily accessible for servicing and routine maintenance of engine and engine components.

-All fluid locations shall be accessible with standard funnels, pour spouts, and automatic dispensing equipment.

-All lubricant sumps shall be fitted with magnetic-type external, drain plugs if available from the component manufacturer as standard or optional.

3.4 ENGINE ACCESSORIES

3.4.1 AIR CLEANER

-Dry type with manual reset, progressive type air restriction indicator included in the engine intake air system.

3.4.2 AUTOMATIC ENGINE IDLE SHUTDOWN

-Engine shall shutdown automatically after a 300 second idle period when the transmission is in the neutral position. Shutdown command can be overridden when the air conditioning is switched to on.

3.4.3 COOLANT HEATER

-All engines shall be equipped with a 120-volt AC coolant heater located in the engine block. Heater shall be engine manufacturer’s standard or optional equipment.

3.4.4 HIGH-IDLE CONTROL

Automatic engine high-idle control shall:

· Be preset to operate at an elevated rate not to exceed the maximum rate permitted by engine manufacturer.

· Operate (engage) when switched to the “ON” position and the transmission in “NEUTRAL” or “PARK” (applicable to design furnished).

· Operate (engage) when the air conditioning is operating and the transmission in “NEUTRAL” or “PARK”.

· Not rely on manual on/off switch position to elevate idle. A low voltage sensing controller can be used to accommodate this requirement in lieu of immediate idle up when A/C is activated.

· Disengage when the service brake pedal is pressed or the transmission in-gear position is selected.

3.4.5 HOUR METER (DIESEL ENGINES)

-All diesel engine buses shall be equipped with hours of operation readout readily accessible without the use of special equipment located in the dash panel. Internal to gauge cluster readout is acceptable.

3.5 TRANSMISSION

3.5.1 PERFORMANCE

-Transmission shall be automatic with a minimum of 5 forward speeds.

-Transmission ratings shall be selected to meet or exceed the maximum horsepower and torque ratings for the engine specified. The net torque capacity and the net power rating of the transmission shall meet or exceed the output ratings of the engine in all gears.

-Fluid shall be synthetic if available from OEM. Allison transmissions shall be equipped with TES-295 approved fluid. Transmission shall be labeled on its exterior to indicate the type of fluid installed.

3.5.2 SHIFT QUALITY & DRIVABILITY

-The overall drivability of the vehicle should not be negatively impacted by the transmission:

· No bumps or vibrations should be felt while shifting

· There should not be a significant delay when downshifting for more torque

· The gears should not be audible during a shift

3.6 BRAKES

3.6.1 SERVICE BRAKES

-Chassis OEM Antilock Brake System shall be furnished.

3.6.2 AIR BRAKES

-The brake system, complete with all necessary components shall include:

· Air Storage Tanks – shall be appropriately rated for application and mounted in such a way to maintain drains at the lowest point for proper water evacuation.

· Automatic Moisture Ejector – the first air storage tank (wet tank) after the air dryer shall be equipped with a heated, automatic, moisture-ejector. All other air tanks shall be equipped with a brass or stainless steel, ¼-turn ball valve drain. The moisture ejector shall be protected from debris damage or accumulation by shielding.

· Air Dryer with replaceable, spin-on cartridge, desiccant air dryer; Meritor Model SS1200 or Bendix AD-IP shall be furnished on all air systems and installed per compressor and air dryer manufacturer’s recommendations.

3.7 AXLES

-The Gross Vehicle Weight Rating (GVWR) and individual axle Gross Axle Weight Rating (GAWR) shall not be exceeded when loaded with the specified number of passengers and baggage including the driver.

-GAWR calculation shall reflect maximum weight ratings as advertised by axle manufacturer and no higher rating of components shall be acceptable.

3.7.1 DRIVE AXLE

-The vehicle maximum road speed shall be electronically governed between 68 and 75 mph.

Differential and bearing lubrication shall be synthetic grease/fluid.

A metal display tag shall be added to the differential fill plug indicating synthetic fluid.

3.7.2 DRIVESHAFT

-Driveshaft protection shall comply with FMCSR 393.89

3.7.3 FRONT AXLE

-Wheel bearings and axle spindles shall be oil lubricated with a window for visual determination of oil level on non-drive axles or “Lubed for Life” permanently sealed unitized hubs shall be provided.

Bearing lubrication shall be synthetic grease/fluid.

-A metal indicator tag shall be added to hub indicating synthetic fluid requirement. The tag is not required for unitized hubs with non-serviceable bearings.

3.8 ELECTRICAL

3.8.1 ELECTRICAL SYSTEM

-All wiring provided by the FSAM shall be copper.

-All wiring shall have type SXL or GXL high temperature cross-linked polyethylene, or better, insulation.

-The use of multi conductor or ribbon cables are permitted provided they are not exposed to under hood or under vehicle temperatures/conditions.

-The wiring shall be permanently color coded or marked the entire length of the wire.

-Wiring shall be routed in conduit or high temperature looms with a rating of 300°F.

-When cables are supplied by a component manufacturer to interconnect system components, these cables need not be continuously color coded/identified. They shall be coded/identified at the termination or interconnection points.

-All added wiring shall be in accessible, enclosed, protected locations and kept at least 6" away from exhaust system components.

-All conduits, looms, and wiring shall be secured to the body or frame with insulated metal cable straps.

-All apertures on the vehicle shall be properly grommeted for passing wiring.

-All items used for protecting or securing the wiring shall be appropriate for the specific application and be standard automotive, aircraft, marine, or electronic hardware.

-Cable ties shall not be used to support harnesses but may be used for bundling purposes.

-Electrical panels that are accessible to accidental contact shall have a protective cover, shield, etc. to prevent shorts that can result in injury, fire, or damage to the electrical system.

-All plastic materials shall be UV resistant and metal supports corrosion resistant:

· P-clamps – Clamps shall be corrosion resistant with a neoprene, Viton, or silicone insulator.

· Saddle-supports – Formed metal support with smooth radius edges designed to carry no less than twice the weight of the harness it supports.

· Cable clamps – Die-formed, radius-edge, corrosion-resistant metal cable clamps and can only be used in bus interior or engine compartment in areas not subject to wetting by rain or road spray. Plastic clamps can only be used in areas not exposed to heat that could exceed their working limits.

· Button-cable ties – Saddle Mounts and button ties utilizing cable ties are an acceptable method of supporting chassis and body wiring and hoses. Cable ties shall be UV resistant and the support method used shall be rated for at least twice the weight of the component supported.

· Nylon tie-wraps with push-wings – an acceptable method of securement in completely enclosed spaces (inside roof and walls). Method must be rated for at least twice the weight of wire supported.

-Electrical circuit board panels and components that are susceptible to accidental contact shall have a protective cover, shield, or enclosed/dedicated compartment to prevent accidental shorts that can result in injury, fire, or damage to the electrical system.

3.8.2 ALTERNATOR

-The maximum alternator RPM rating shall not be exceeded at the top governed engine RPM.

-The output values must meet or exceed those listed in the Minimum Requirements for each Standard Item.

3.8.3 BATTERIES

-Batteries shall be mounted in a fully enclosed box made of a material intrinsically resistant to damage or corrosion due to battery acid exposure and capable of supporting the full weight of the batteries without assistance.

-The placement of the batteries should allow for complete visual inspection and service of terminals without removing battery cables.

-All components within the battery compartment shall be protected from battery electrolyte and gas corrosion.

-Only battery cables shall be connected to batteries.

-Battery cables shall be routed through dedicated holes in battery box independent of each other and insulated from abrasion by grommets.

-No spliced battery cables permitted. Cables shall be one-piece, stranded conductor with protective covering (jacket) pigmented red to indicate positive and black to indicate negative and shall be run from the positive battery terminal of the leading battery directly to the starter solenoid.

3.8.4 AUXILIARY INTERIOR POWER RECEPTACLE

-Shall be 12-volt powered with 10-amp minimum supply located in the driver’s area.

-Receptacle shape shall be like a cigar lighter.

3.8.5 120-VOLT SHORE POWER (WITH 120VAC INTERIOR OPTIONAL EQUIPMENT ORDER)

-All powered components requiring alternating current (ac) shall operate on 120-volt (v), 60 Hz.

-The power inlet connector shall be polarized and of the grounding type and shall be listed as suitable for the purpose.

-The power inlet connector shall be in a weatherproof housing with a spring-loaded and gasket sealed cover.

-The inlet connector shall be constructed and installed to guard against inadvertent contact by persons with parts made live. The inlet connector shall be provided with a grounding pole with a first to make and last to break contact. The supply equipment shall have sufficient rating to supply the load served.

-All electrical and heating materials shall be listed or labeled by a Nationally Recognized Testing Laboratory i.e.: UL/CSA/ETL and shall be installed in accordance with both the manufacturers’ instructions and the National Electrical Code.

3.9 FUEL

3.9.1 FUEL SYSTEM

-Shall comply with FMCSR 393.65, 393.67, and 393.69 -All diesel engines shall be furnished with a fuel/water separator with the following attributes:

· Replaceable filter element or cartridge rated no larger than 30 microns.

· Drain valve that allows for water and debris to be drained from lowest point of unit.

· Water sensor for warning light.

· The separator can be remote mounted or internal to the engine

3.9.2 FUEL TANK(S)

-When the tank filler cap is located behind body skin, a hinged access door shall be furnished.

-Fuel fill(s) shall permit filling of tank(s) with only the nozzle end of the fuel handle.

-Fuel filler cap(s) shall be attached with a cable or chain to prevent loss.

-Fuel type shall be indicated on the body skin immediately next to fill cap or on the inside face of the fuel fill door. The words “Ultra Low Sulfur Diesel” must be included when applicable.

3.10 EXTERIOR

3.10.2 EXTERIOR MIRRORS

-Motorized remote controlled and heated surfaces with controls located in driver’s area for flat mirrors. Heat and position control switch(s) shall be “Marked to Indicate Function” and located in the driver’s area. Heating function shall be automatically deactivated when the ignition switch is turned to the “OFF” position. A Pictogram can be used to identify mirror switches and functions.

3.10.3 LICENSE PLATES

-Front and rear license plate mounting provisions shall be furnished and comply with SAE J686.

3.10.4 STOWAGE COMPARTMENT

-Provision shall be made for lockable weatherproof stowage of tire changing tools and tire chains.

3.10.4 OTHER PLATES AND DECALS

-Dealer identification decals and placards shall not be applied to vehicle exterior. Bus manufacturer decals are permitted so long as they do not interfere with other required or specified markings.

3.10.5 EXTERIOR PAINT

-The standard exterior color of buses shall be bright white unless otherwise specified by option in paragraph 3.25.

-Roof shall be painted bright white regardless of optional color choices.

3.11 DOORS AND WINDOWS

3.11.1 PASSENGER DOORS

-Passenger door shall comply with ADA requirements.

-Shall comply with FMVSS 217

3.11.2 KEYS

-Exterior access panels to the engine compartment, battery compartment, doors, and storage compartments shall be keyed. Passenger entry and exit doors can be electronically or mechanically locked.

-If engine compartment is not keyed, it should only be able to be opened with a release inside the vehicle -Duplicate keys shall be furnished with each bus.

3.11.3 STEPS

-Applicable to Standard Items 359W, 360, 360W, 363, 363W.

-Shall comply with ADA guidelines.

-Galvanized steel, stainless steel, or aluminum can be used to construct the passenger stepwell.

-The material chosen for the stepwell construction must be compatible to the surrounding body structure.

-Exterior or interior surfaces shall be covered or coated with an insulator to reduce heat and sound transfer.

-Rubber or vinyl flooring will not be considered an insulating material for vertical surfaces. Undercoating will not be considered an insulator for the exterior of the stepwell.

-Square vertical leading edge of stepwell shall have a flat surface to provide a positive seal where doors contact stepwell or otherwise provide a positive seal for doors to prevent intrusion of water, dirt, wind, etc.

3.11.4 Entry Ramp

-Applicable to Standard Item 360L.

-All low floor buses shall not use steps for passenger entry other than that from the ground to the landing inside the door.

-An electric deploying and retracting wheelchair ramp shall be provided as standard equipment on all low-floor buses to allow for a no step entry from the ground to the bus interior when deployed.

-Entry ramps shall comply with ADA guidelines and be surfaced with slip resistant and replaceable cover.

3.11.4 EMERGENCY EXITS

-Shall comply with FMCSR 393.61, 393.62, 393.63, 393.92.

3.11.5 PASSENGER WINDOWS

-Provided with fingertip control, permitting ready opening and adjustment to various desired openings.

-Rattle proof and, when closed, waterproof and windproof.

-All windows shall be fitted with latching devices.

3.11.5.1 TINTING

-Chassis manufacturer’s tinted windshield shall be furnished.

-Windows on the bus sides and in the rear door shall be tinted a neutral color, complementary to the bus exterior.

-Windows over the destination signs shall not be tinted.

3.11.6 WINDSHIELD DEFROSTING

-Shall comply with FMVSS 571.103, FMCSR 393.79, and SAE J381

3.11.8 WINDSHIELD WIPING AND WASHING

-Shall comply with FMCSR 393.78, and SAE J198

3.12 LIGHTS AND LIGHTING

3.12.1 EXTERIOR LIGHTING

-All exterior lights on the vehicle shall comply with ADA 1192.31, FMCSR 393.11, 393.19, 393.22, 393.23, 393.24, 393.25, 393.26, and SAE J589, and J910.

-The following exterior lighting shall be Light Emitting Diode (LED): rear tag, tail, stop, turn, clearance, and door area ground/curb illumination.

-Exclusions to LED requirement are wheel chair door area and ground lighting, headlamps, and other lights that cannot be replaced by a LED due to a design only available in incandescent or when multiple LED assemblies cannot be used to take the place of an incandescent fixture due to space limitations.

-LED lighting shall have a minimum 5-year warranty.

-All exterior lights shall be grounded with an insulated wire.

-The ground lead shall not be secured by the lamp fixture mounting screws or hardware.

-A terminal shall be attached to the wires by a simple mechanical crimp-type process that conforms to SAE J163.

-Ground terminal lugs shall be solder plated, cadmium, tin or zinc plated.

-Ground terminals should be clustered and shall be accessible for servicing.

-A serrated paint-cutting terminal shall be utilized to make proper contact when used on painted surfaces.

-When two wire lights are not commercially available, then ground return connections may be made to vehicle structure, frame or engine using the ground-return system (one wire systems per SAE J1292).

-Lights and reflectors shall not be mounted on rub rails or vehicle bumpers unless recess protected.

-Reflectors must be a sticker type flexible material. The sticker must use cube corner elements to reflect light such as 3M Diamond Grade. Rigid plastic stick on or screw-on reflectors are not permitted.

-All lights or powered components mounted on hinged covers or doors shall have a flex loop secured at both ends to allow for normal opening of cover without damaging wires.

-Clearance lamps shall be low-profile design or body recessed to prevent damage from tree limbs. -Armor shields shall not be supplied to protect lighting unless supplied commercially as standard equipment.

-All buses shall be equipped with three-wire combination side marker/turn signal lamps.

-The lamp shall be positioned below the passenger windows, nominally center of body or forward to the rear of the passenger door and driver’s side window.

-A two wire LED marker lamp can be used in place of the three wire combination light so long as the illumination spread is nominally 270 degrees wide and the lamp is configured to operate as a marker continuously and then flash when driver requested, acting as a side turn signal.

-All exterior housings of lamps, switches, electronic devices, and fixtures shall be corrosion resistant and weatherproofed.

-Ground and step illumination shall be furnished to meet ADA guidelines. Lamps shall activate when the passenger entry or exit door is open.

3.12.2 INTERIOR LIGHTING

-Interior lighting shall include:

· Minimum one row of SMI TRANSIT LF light emitting diode (LED) light fixtures installed center of aisle or integrated into overhead parcel racks when requested by option.

· The fixtures shall extend as far to the rear of the bus and as far forward as possible in continuous joined assemblies.

· A gap is permitted in the lamp assemblies when obstructions such as roof hatches prevent continuous lengths.

· Lens material shall be polycarbonate. Lens material shall not drip flaming onto seats if burned. Lens shall be sealed to inhibit incursion of dust and insects yet are easily removable for service. If threaded fasteners are used they must be held captive in the lens.

· The light fixtures shall be powered when the passenger entry or exit door is opened. A manual override switch shall be provided to allow the driver to leave the interior lights on at all times so long as the ignition key is in the run or auxiliary position.

-White light emitting LED lamp assemblies can be used in place of the SMI fixtures with the number and brand of the fixtures at the discretion of the Contractor so long as the lamps meet the requirements of subparagraphs C and D. Lamps can be permanently sealed or contain replaceable elements.

-Minimum illumination values are below. All values must be measurable over the entire surface area.

· Center aisle surface- no less than 2 foot candles per square foot.

· Entry and exit stepwell surfaces or ramp surface as applicable, no less than 2 foot candles per square foot.

· All other interior passenger floor area surfaces, no less than 0.4 foot candles per square foot.

· The foot candle values listed in subparagraph “e” shall be measured using a light meter placed on the floor surface.

· A minimum of one LED dome light with no less than 4 foot candle output measured on top of the lower seat cushion shall be furnished over the driver’s area controlled independently of other interior lighting.

-The passenger entry and exit doorstep lighting must activate when the door is open

3.13 ELECTRONICS/AUDIO VISUAL

3.13.1 RADIO

-AM/FM with USB, Aux, or Bluetooth Input radio shall be furnished with an integrated public address system consisting of a handheld microphone with button control.

-Minimum of two premium quality speakers shall be provided for every three rows of seats but not less than four speakers.

3.14INTERIOR
3.14.1AIR CONDITIONING SYSTEM

-Bus manufacturer’s highest output BTUH/HR system shall be furnished as standard.

-Independent dash air conditioning must be furnished as standard equipment.

-The system capacity must be calculated as follows:

1. add together all evaporator capacities

2. add together all condenser capacities

3. add all compressor capacities.

-The BTUH/HR capacity stated must be the lowest added value. Dash air conditioning system must be added to the passenger compartment lowest added value and considered part of the total Air Conditioning Output listed in the Minimums for each Standard Item.

-The system shall be electronically controlled and have the capability of self-diagnostics.

-Evaporator fan speed control and thermostat setting shall be digital and located in driver area.

-Minimum diagnostic outputs and system protections shall include high pressure, low pressure.

-Automatic tensioning compressor drive belt(s).

-Added refrigerant compressors can be a swash plate type with not less than 163 cc / 10 CID displacement.

-The chassis manufacture’s dash defroster system shall not be tapped into as part of the passenger compartment cooling.

-The passenger compartment air conditioning system, excluding the OEM dash unit, must have the system manufacturer’s recommended filter/drier and a refrigerant moisture indicating sight glass located to be readily viewable.

-All air shall pass through the evaporator filter system.

-Condensation drains shall be enough to evacuate all water accumulated in evaporator and prevent standing water.

-All system components subject to corrosion from moisture shall be aluminum, copper, stainless steel, galvanized, or epoxy coated.

-Condenser(s) can be skirt or roof mounted as standard.

-Evaporators can be free blow, ducted, or a combination to attain an even air flow and temperature environment.

-The compressor input RPM must not be exceeded at full engine RPM.

3.14.1.1 AIR CONDITIONING INSTALLATION

-System components shall not interfere with or adversely affect chassis OEM and bus body systems, components, function, reliability, and fit.

-Installation of the evaporator(s) and ancillary equipment inside the vehicle shall be mounted away from the head impact zone as specified in FMVSS 222.

-System shall be installed on the assembly line in accordance with the A/C manufacturer’s documented instructions.

-All lines, hoses, cables, wires, and harnesses shall be rigidly supported at distances not greater than 20-inches. Cable ties or straps of any kind shall not be used to support any lines or hoses. UV-resistant cable ties are acceptable only for bundling.

-All line, hose, cable and wires shall pass-through grommeted holes.

-All body penetrations shall be sealed with an elastomeric sealing compound if grommeting alone cannot provide a tight seal against the entry of water, fumes, or dust into the passenger compartment.

-All mounting hardware shall be stainless steel or other corrosion resistant materials.

-No sheet metal screws shall be used in mounting equipment within contact of hoses.

-Condenser(s) shall be fit with a recirculation guard to aid fresh air flow across coils.

-Skirt mounted condensers shall be designed and located to prevent road debris and water splash from clogging or damaging the condenser.

-System charging and monitoring access ports shall be in areas where they will not be subject to damage from foreign objects while bus in motion. Ports shall be readily accessible without the need to remove components or permanently secured panels.

3.14.1.2 AIR CONDITIONING PERFORMANCE

-The BTUH/HR capacities shall be based upon the SAE individual component ratings including compressor, evaporator, condenser, and all ancillary refrigeration components.

-The evaporator shall be tested at 80 degrees F dry bulb/ 67-degree F wet bulb in 37 degrees F saturated evaporating refrigerant temperature versus air entering the evaporator.

-Condenser shall be tested at 95 degrees F with saturated refrigerant temperature as 45 degrees delta T.

-The following test must be used to validate air-conditioning performance:

· The bus must be heat soaked to 100 degrees F for not less than two hours in a controlled environment prior to testing.

· A relative humidity of 50% shall be maintained in the test chamber during testing.Thetesting. The system must cool the interior of the bus from 100 degrees F to 70 degrees F in no more than 30 minutes with the engine at an elevated RPM and all standard components of the bus and climate control system installed during the test.

· Interior temperature must be measured at not less than three points inside the bus along the centerline and located four feet above the floor.

· The minimum three points of measure shall be (1) three feet above the center pint of the horizontal driver seat surface, (2) at the longitudinal midpoint of the body, and (3) three feet forward of the aisle end.

· The temperature probes inside the bus must be within +/3 degrees F of the average temperature at the conclusion of the test.

3.14.2 HEATING

-Passenger compartment heating shall be provided using heat exchangers integrated into the air conditioning system or by radiant heaters located along the interior walls.

-All buses shall have a means of heating the air in the passenger door stepwell.

3.14.4 DRIVER’S AREA

-Driver’s area shall include as a minimum:

· Shall comply with FMCSR 393.51

· All switches and controls shall be marked with easily read identifiers

· Ignition switch

· Push button start is acceptable if the power supply to the switch is controlled by a keyed switch or electronic recognition.

· Tilt steering wheel/column

· Engine coolant temperature overheat warning

· Engine low oil pressure indication

· Fuel level indicating gauge

· Transmission selector

3.14.5 INTERIOR MIRROR

-Minimum of one non-glare type mirror shall be mounted inside the bus with a reflective surface area of not less than 80 square inches with rounded corners. Driver shall be able to view complete passenger compartment through interior mirror.

3.15 FLOOR

3.15.1 FLOOR CONSTRUCTION

-Interior sub-floor shall be metal, covered with not less than a minimum of 5/8-inch nominal thickness, marine grade plywood, with all ends sealed. Alternative synthetic materials may be acceptable.

-Top surface must be not less than a grade B with bottom no worse than a grade C.

-All wood and wood product ends shall be sealed and securely fastened to the metal stringers prior to be covered with matting.

-All surfaces exposed to weather shall be coated with a waterproofing substance such as undercoating or epoxy surfaces.

-All floor fasteners shall be of corrosion resistant materials.

3.15.2 FLOOR COVERINGS

-Floor covering shall be permanently bonded to the sub-floor and shall be impervious to temperature changes. Bonding or adhesive material shall be waterproof, including joints and seams, and shall be of the type recommended by the manufacturer of the floor covering material.

3.15.3 WHEEL-HOUSINGS

-Wheel-housings, which protrude into the passenger compartment, shall be covered with the same matting used under the seats or a material equal in durability as the flooring material. The wheelhouse shall be designed in shape and strength so it may be used as a footrest.

3.16 WALLS

-The standard interior walls for items 359W, 360, 360W, 363, and 363W shall be covered with medium grey color padded, woven, stain resistant industrial cloth fabric or carpet complying with FMVSS 571.302.

-The standard interior walls for item 360L shall be white to light grey melamine surface.

3.18 SEATS

3.18.1 DRIVER’S SEAT

-EXCEPTION: If the OEM does not allow the replacement of OEM seats due to safety reasons, the driver’s seat does not need to meet all of the specifications below. During the first article inspection, we will require documentation from the OEM which supports your claim. The features that are missing from the seat will also need to be indicated on the clarifications tab.

-The following features must be furnished as standard equipment:

· Grey weave fabric

· Triple Adjustable lumbar

· Adjustable bolsters

· Front cushion adjuster

· Rear cushion adjuster

· Adjustable cushion length

· Back recline – minimum recline 9 inches or 23 degrees from full upright position with seat set in the center of seat track travel.

· Seat tracks – minimum seat travel must be 7 inches.

· Right movable arm rest

· Seat height adjust with air cylinder suspension

· 3-point belt system

· The driver’s seating position must accommodate a 95th percentile male which is 6 feet 2 inches tall and weighs 223 pounds and a 5th percentile female at 5 feet tall and 110 pounds.

3.18.2 PASSENGER SEATS

-The required passenger count for the low floor buses may be met by a combination of standard seating and single folding or flip and fold seats in the wheelchair locations. When using single folding seats in the wheelchair locations they can be doubles or triples at the bus manufacturer’s discretion -Passenger seating shall comply with FMVSS 571.217 and 222 seating and leg room requirements.-Hip-to-knee room, measured from the front of one seat back horizontally across the highest part of the seat cushion, at the center of the seat, to the seat back or panel immediately in front shall be no less than 27-inches at all forward facing seating positions.

-Foot room, measured at the floor forward from a point vertically below the front of the seat cushion to an obstruction such as the driver barrier, shall be no less than 12 inches.

-Seats immediately behind the wheel housings may have foot room reduced, provided the wheelhouse is shaped so that it may be used as a footrest.

-3-point restraints shall be supplied if required under FMVSS for bus GVWR.

-Partial perimeter seating is acceptable for low floor models where it is not practical to use forward facing seats due to passenger comfort issues.

3.19 SAFETY

3.19.1 BUMPERS

-Front and rear bumpers shall be manufacturer’s standard metal -Bumpers shall not contact body -Bumpers shall be painted, e-coated, or anodized on all sides prior to installation.

-Back surface of bumper can be epoxy primed in the absence of top coating if not visible during normal operation.

3.19.2 STANCHIONS, BARRIERS, AND GRAB RAILS

-Barrier panels shall be furnished between the stepwell and the passenger seats and immediately behind the driver’s area.

-The installation of the driver’s barrier shall not interfere with the full reward motion of the driver’s seat.

-ADA compliant handrails are required at the front and rear of the passenger entrance shall be arranged to safely assist passengers entering or leaving the bus -All stanchions and grab rails shall be ADA compliant stainless steel, epoxy coated, or padded injection-foam covered tubing. If padded tubing is used, the foam must meet all FMVSS requirements and be vandal resistant transit quality material. Opaque barriers shall be covered with the same material as the wall covering unless formed from injection molded plastic.

-All stanchions, barriers and grab rails shall be attached to tapping plates in walls, floor and ceiling if no structural members are available.

3.19.3 EMERGENCY EQUIPMENT

-Shall comply with FMCSR 393.95 -Fire extinguisher mounted convenient to the driver.

-The fire extinguisher shall have an Underwriter’s Laboratory rating of 2A 10 B:C or greater, shall be a minimum 5 pounds, shall have a hose, shall include a metal safety pin and wire, and shall conform to type I or type II, class 2, size 5 of A-A-393.

-The fire extinguisher shall permit visual determination of charge.

-Minimum of 10-unit type first-aid kit shall be furnished.

3.20 SUSPENSION

3.20.1 GROSS VEHICLE WEIGHT RATINGS

-Vehicle GVWR’s shall be the chassis manufacturer’s published ratings.

-Component and vehicular ratings shall not be increased to meet the requirements of this Specification.

-When published ratings are not available, verification of rating shall be made available upon request by the Government.

3.20.2 FRONT SUSPENSION, STANDARD FLOOR

-Applicable to Standard Items 359W, 360, 360W, 363, and 363W.

-Manufacturer’s standard spring material and design.

3.20.3 FRONT SUSPENSION, LOW FLOOR

-Applicable to Standard Items 359L and 360L -Manufacturer’s air suspension or air over spring design.

-Curbside kneeling function.

-The switch to kneel the suspension must be located in the driver’s area and not readily accessible to the passengers.

-When the command to kneel is activated a warning light and audible signal shall announce the vehicle is lowering down.

-An interlock must prevent the vehicle from moving until the air springs are at normal operating height.

3.20.4 REAR SUSPENSION, STANDARD FLOOR

-Applicable to Standard Items 359W, 360, 360W, 363, and 363W.

-Manufacturer’s air suspension.

3.20.5 REAR SUSPENSION, LOW FLOOR

-Applicable to Standard Items 359L and 360L -Air suspension with curbside kneeling function.

-Safety interlocks to prevent vehicle movement with deflated air springs

3.21 TIRES AND WHEELS

3.21.1 TIRES

-Shall comply with FMVSS 571.119 and 571.120 -Tubeless, steel belted radial tires with highway tread and a minimum speed rating of 75 mph.

3.21.2 WHEELS

-Wheel/Tire size and ply rating shall be the same for all wheels/tires.

-Shall be manufacturer’s standard color

3.22 MISCELLANEOUS

3.22.1 OPERATION MANUALS & 1398 FORM

-Operation manuals shall be furnished with each bus.

-The Contractor shall fully complete and affix a GSA Form 1398 to the vehicle in the Driver's area. The exact location shall be agreed upon during the First Production Vehicle Inspection by both the Contractor and GSA Quality Assurance Branch Representative assigned to the facility

3.22.2 SERVICING AND ADJUSTING

-Prior to acceptance of the vehicle by the Government, the Contractor shall inspect, service and adjust each vehicle for operational use in accordance with an approved manufacturer’s prescribed pre-delivery servicing form.

- The in-transit mileage accumulation on vehicles driven from the assembly plant to the receiving location shall be recorded and the start of warranty coverage adjusted to begin once the bus reaches the destination address.

-The areas to be inspected and adjusted, if necessary, shall include as a minimum:

· All fluids and fuel tank(s) shall be full.

· Alignment of headlights.

· All engine adjustments.

· Electrical and brake systems.

· Filling and charging of batteries.

· Alignment of front wheels.

· Inflation of all tires.

· Complete lubrication of body, chassis, engine and running gear with grade of lubricants recommended for the ambient air temperature at the delivery point.

· Servicing of the cooling system with a solution of ethylene glycol type antifreeze and water in equal parts by volume.

· Servicing of the windshield washer reservoir with water and appropriate additives.

3.26 GENERAL WORKMANSHIP REJECTION STANDARDS

The following shall be reason for rejection:

· RA rough, sharp or unfinished edges, burrs, seams, corners, joints, cracks, and dents. Sharp corners and edges shall be either rounded or padded to prevent injury to personnel.

· Interior cleanliness: vehicle interior should not contain trash or manufacturing debris…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .