This electrical exhibit drawing file supports ITB 26-138, a solicitation by Citrus County, Florida for airfield lighting and navigational aid improvements at Crystal River Airport. The project encompasses removal and replacement of Runway End Identifier Lights (REILs) on both runway ends, runway edge lighting on Runway 9-27, and Taxiway A edge lighting, along with associated electrical infrastructure upgrades including cabling, connectors, transformers, regulators, and light bases. The bid is structured into three schedules: Schedule A covers REIL replacements (4 units total—2 for Runway 9 and 2 for Runway 27); Schedule B addresses taxiway lighting improvements including 94 elevated LED taxiway edge light bulb replacements, 2 in-pavement LED taxiway edge light bulbs, and 10 fixture replacements; Schedule C includes runway lighting improvements with 42 elevated LED runway edge light bulbs, 16 elevated LED runway threshold light bulbs, 2 in-pavement runway edge light bulbs, and 10 fixture replacements. The drawings indicate that Runway 27 REIL replacement requires new concrete foundation, junction cans, and conduit replacement, while Runway 9 REIL installation can utilize existing foundation and conduit. Bids were due July 14, 2026, with the solicitation addendum posted June 23, 2026.

The project is funded jointly by the Florida Department of Transportation (FDOT) and Citrus County. The County reserves the right to award one or multiple bid schedules to the apparent low bidder(s) based on available funding and the County's best interest. Contractors will be compensated for the actual quantities of bulbs and fixtures replaced in the field, with replacements required to match existing styles and types. The electrical specifications and complete solicitation documents, including the sample agreement and grant agreement (FPN 457353-1-94-01), provide detailed requirements for the work scope, payment procedures using AIA G702-G703 format, and all contract terms.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

18" CONCRETE PIPE

INV. EL. = 3.22

INV. EL. = 3.02

MES. 5'W x7.5'L

MES. 5'W x7.5'L

8'X15' C\S

46' X 0.67' WEIR WITH 17' STAINLESS SKIMMER

TYPE-E

INLET No.

TYPE-E

INLET No. 15

18" C.M.P.

DRAINAGE RETENTION AREA

OUT FALL No.

JUNCTION BOX No. 2

"X

H E

R C

P

" C

.M .P

OUT FALL No.

10.0'X10.0' C/S

C/S 10.0'X10.0'

OUT FALL No.

MITERED END

46' X 0.67' WEIR WITH 11.0' STAINLESS SKIMMER

10.0'X10.0' C/S

TYPE-E

INLET No.

TYPE-E

INLET No. 14 OUT FALL No. 18" C.M.P.

MITERED END

OUT FALL No. 18" C.M.P.

MITERED END

13 18" C.M.P.

TYPE-E

INLET No. 11

18" C.M.P.

TYPE-E

INLET No.

18" C.M.P.

TYPE-E

INLET No.

18" C.M.P. 18" C.M.P.

TYPE-E

INLET No.

TYPE-E

INLET No. 8

C

M

JUNCTION BOX No. 1

8 OUT FALL No.

15"X21" CMP

MITERED END

9 OUT FALL No.

MITERED END

X

C

M

TYPE-C INLET No.1

TYPE-E

INLET No. 10

OUT FALL No. 10

MITERED END

TYPE-E

INLET No.

TYPE-E

INLET No. 7

18" C.M.P.

18" C.M.P.

14"x23"H.E.R.C.P.

OUT FALL No.

MITERED END

DRAINAGE

CONC.

TYPE-E

INLET No.

18" C.M.P.

OUTFALL No.

18" C.M.P.

MITERED END

18" C.M.P.

TYPE-E

INLET No. 2

18" C.M.P.

H.E.R.C.P.

14"x23"

14"x23"H.E.R.C.P.

TYPE-E

INLET No. 1

18" C.M.P.

H.E.R.C.P.14"x23"

14"x21" ECM P

MITERED

END

RETENTION AREA

MITEREDEND

CONCRETE

RIP-RAP BAGS ( OUTFALL INVERT EL.9.02 )

INVERT EL.9.3815" ROUND CONCRETE PIPETOP OF SKIMMER EL.11.49

WEIR EL.9.54

3.4' x 3.4' CONCRETE BOX (.65' WALL THICKNESS)

ALUMINUM SKIMMER

6"P.V.C. INVERT EL.9.30

4"P.V.C. INVERT EL.9.21

8"P.V.C. INVERT EL.9.21

INV ELEV.

=4.05

INV ELEV.

=3.21

INV ELEV.

=3.48

INV ELEV.

=3.62

12"RCP

INV ELEV.

=3.57

"R

C P

INV ELEV.

=3.26

INV ELEV.

=3.35

CONC. OUTFALL

12"RCP

ROCK

D.R.A.

(BOTTOM

=3.26)

STRUCTURE

INV ELEV.

=2.98

BOTTOM

=2.00

GROUTED ROCK

WITH CONC.

JB

JBJB

R G

R G

R G

R G

R G R G R G R G

RG

RG

RG

RG

RG

RG

RG

RG

REFERENCE

MONUMENT

5/8" I.R.C.

CITRUS ENG

LB 6636

FLORIDA ARMY

NATIONAL GUARD

RUNWAY 9-27

N. LINDBERGH DR.

BICENTENNIAL PARK

N. LINDBERGH DR.

U .S

.H

IG

H W

AY

TU

R

F R

U N

W

AY

8/

2, 6' x1

W. VENABLE ST.

CEMETERY

W. FLIGHT PATH CT.

N . G

O

LF

C O

U R

SE

D

R

N . G

O

LF

C O

U R

SE

D

R

W SEVEN RIVERS DR.

REPLACE EXISTING

ELEVATED LED

TAXIWAY EDGE LIGHT

BULB (TYP.)

REPLACE EXISTING

ELEVATED LED

RUNWAY EDGE LIGHT

BULB (TYP.)

REPLACE EXISTING REIL

REPLACE EXISTING IN

PAVEMENT LED

RUNWAY EDGE LIGHT

BULB (TYP.)

REPLACE EXISTING REIL

AND FOUNDATION

U :\T

AM

PA

\A

VI

AT

IO

N \C

IT

R

U S

C O

U N

TY

\C

G C

R W

E

XT

\C G

C E

LE

C

TR

IC

AL

F

IL

ES

\C G

C E

LE

C

TR

IC

AL

E

XH

IB

IT

.D

W G

4/ 8/

:5

7:

A M

NOT FOR CONSTRUCTION

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

SHEET NO.

Mead and Hunt, Inc.

DES

ACC

ACC

U :\T

AM

PA

\A

VI

AT

IO

N \C

IT

R

U S

C O

U N

TY

\C

G C

R W

E

XT

\C G

C E

LE

C

TR

IC

AL

F

IL

ES

\C G

C E

LE

C

TR

IC

AL

E

XH

IB

IT

.D

W G

4/ 8/

:5

7:

A M

N L

IN

D

BE

R

G T

ER

R

AC

E

C R

YS

TA

L R

IV

ER

A

IR

PO

R

T R

U N

W

AY

9-

EL

EC

TR

IC

AL

R

EP

AI

R S

C R

YS

TA

L R

IV

ER

, F L

MARCH 26, 2026

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

00 200 400

PROJECT SITE PLAN

EXH - 1

Item Number Scope of Work Unit of Issue Quantity BID SCHEDULE A- Runway End Identifier Lights (REILs)

1 Replace Runway 9 REILS EA 2 2 Replace Runway 27 REILS with New Foundation EA 2

BID SCHEDULE B- Taxiway Lighting Improvements

3 Replace Existing Elevated LED Taxiway Edge Light Bulb EA 94 4 Replace LED In-Pavement Taxiway Edge Light Bulb EA 2

5 Replace Existing LED Elevated Taxiway Edge Light Fixture and Bulb and Associated Work EA 10

BID SCHEDULE C- Runway Lighting Improvements

6 Replace Existing LED Elevated Runway Edge Light Bulb EA 42 7 Replace Existing LED Elevated Runway Threshold Light Bulb EA 16 8 Replace LED In-Pavment Runway Edge Light Bulb EA 2

9 Replace Existing LED Elevated Runway Edge Light Fixture and Bulb and Associated Work EA 10

NOTES:

1. EXISTING REILS SHALL BE REPLACED AS NOTES. THE RUNWAY 27 REILS SHALL

REQUIRE REPLACEMENT OF THE EXISTING CONCRETE FOUNDATION. CONDUIT AND

CABLE IN THESE LIMITS WILL REQUIRE REPLACEMENT. RUNWAY 9 REIL

REPLACEMENT ONLY REQUIRES REPLACEMENT OF THE REIL. EXISTING FOUNDATION

AND CONDUIT SHALL BE REUSED. SEE EXHIBIT 2 FOR ADDITIONAL INFORMATION.

2. EXISTING LED RUNWAY AND TAXIWAY EDGE LIGHTS SHALL HAVE BULBS REPLACED

AS NOTED. CONTRACTOR SHALL BE PAID FOR THE ACTUAL AMOUNT OF BULBS

REPLACED. BULBS TO MATCH EXISTING.

3. A QUANTITY OF EDGE LIGHT FIXTURE REPLACEMENT HAS BEEN INCLUDED IN THE BID

FORM. THE CONTRACTOR SHALL BE PAID FOR THE QUANTITY OF FIXTURES

ACTUALLY REPLACED. FIXTURES SHALL MATCH EXISTING STYLE AND TYPE. NO BASE

CAN REPLACEMENT IS REQUIRED.

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

SHEET NO.

Mead and Hunt, Inc.

DES

ACC

ACC

U :\T

AM

PA

\A

VI

AT

IO

N \C

IT

R

U S

C O

U N

TY

\C

G C

R W

E

XT

\C G

C E

LE

C

TR

IC

AL

F

IL

ES

\D

ET

AI

LS

\R

EI

L D

ET

AI

L.

D

W G

4/ 8/

:5

6:

A M

NOT FOR CONSTRUCTION

N L

IN

D

BE

R

G T

ER

R

AC

E

C R

YS

TA

L R

IV

ER

A

IR

PO

R

T R

U N

W

AY

9-

EL

EC

TR

IC

AL

R

EP

AI

R S

C R

YS

TA

L R

IV

ER

, F L

MARCH 26, 2026

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

M

IN

IM

U

M

EXH - 2

REIL DETAIL

REFERENCE NOTES:

1. RUNWAY 27 REILS SHALL REQUIRE A NEW CONCRETE

FOUNDATION, JUNCTION CANS, AND CONDUIT WITHIN THESE

LIMITS. EXISTING CONDUIT OUTSIDE THESE LIMITS CAN BE

REUSED.

2. RUNWAY 9 REILS CAN BE INSTALLED ON EXISTING FOUNDATION

AND REUSE EXISTING CONDUIT AND JUNCTION CANS.

CONCRETE FOUNDATION/

ENCASEMENT (PER

SPECIFICATION P-610)

Sheets and Views
CGC ELECTRICAL EXHIBIT-MH22x34

File details come from the government source that posted it. Updated .