CES - STATEMENT OF WORK - Billboard.docx

DOCX document 44 KB Posted

Attached to
181 Billboard
Solicitation number
W50S7V26QA007
Issued by

About this file

This is a Statement of Work (SOW) for the procurement, structural engineering, delivery, and installation of a freestanding billboard framework at the 181st Intelligence Wing, Terre Haute Air National Guard Base in Terre Haute, Indiana. The project requires turnkey delivery of a billboard structure with specific technical specifications: a 32-foot-wide by 12-foot-high display area designed to support twelve factory-coated aluminum panels (4' x 8' dimensions, 1/4" thickness), with a maximum ground clearance of 1½ feet above finished grade. The concrete foundation must be constructed to UFC 3-301-01 and ACI 318 standards with a minimum compressive strength of 4,000 PSI at 28 days, air-entrained composition (5-7% air content), and reinforced with ASTM A615 Grade 60 deformed rebar. The concrete pad must feature a one-foot offset extending outward from the billboard's perimeter, finished to a flat, smooth trowel profile suitable for future brick and mortar work.

The contractor's scope includes submitting structural drawings with concrete pad dimensions, reinforcing steel schedules, and wind load compliance documentation; performing site preparation including utility clearance, excavation, subgrade compaction per UFC standards, formwork construction, steel placement, and concrete pouring; and completing structural framing procurement and installation. The contractor must verify maximum ground clearance compliance, conduct final cleanup and form removal, and perform joint inspection with the Contracting Officer Representative. Quality requirements include providing concrete delivery tickets verifying mix design and compressive strength, submission to field slump and cylinder break testing, adherence to OSHA and Department of War safety standards, and a comprehensive warranty covering concrete cracking/spalling, structural steel deformation, and foundation shifting. The period of performance is negotiable, with the contractor proposing the required timeline for procurement and installation.

View the file

Other files

File Type Posted
Soil Report_2018.pdf PDF
ASCEDesignHazardsReport.pdf PDF
Site Location Map.pdf PDF
RFI Responses (version 3).pdf PDF
1. Solicitation - W50S7V26QA007 - 181 Billboard.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW)

Project Title: Billboard Structure Procurement and Installation

1. Project Overview

1.1 Objective

Turnkey procurement, structural engineering, delivery, and installation of a freestanding billboard framework designed to support aluminum panels, including UFC-compliant concrete pad construction.

1.2 Location

181st Intelligence Wing, Terre Haute Air National Guard Base 800 S Peterchef St.

Terre Haute, IN 47803

1.3 Period of Performance

Negotiable. Contractor to propose timeline required to procure and install.

2. Technical Specifications The contractor shall ensure all materials and installations meet the following exact structural and physical criteria:

· Display Area Dimensions: 32 feet (width) by 12 feet (height).

· Ground Clearance: The bottom edge of the structural framework shall sit no higher than 1 1/2 feet above finished grade.

· Concrete Pad Geometry: A ground-level concrete pad must outline the perimeter of the billboard structure, featuring a one-foot offset extending outward from all outer edges of the billboard's footprint.

· Concrete Pad Finish: The surface must be finished to a flat, smooth, level profile (such as a hard steel trowel finish) to facilitate the future bonding and adherence of brick and mortar.

· Concrete Compressive Strength: Minimum 4,000 PSI compressive strength at 28 days, strictly conforming to UFC 3-301-01 and ACI 318 structural standards for exterior slabs on grade.

· Concrete Durability & Mix: Air-entrained concrete (5% to 7% air content) to withstand localized freeze-thaw cycles and weather exposure.

· Steel Reinforcement: Reinforced with ASTM A615, Grade 60 deformed rebar or structural welded wire reinforcement (WWR) as designated by structural wind-load engineering.

· Subgrade Preparation: Compacted base/subgrade quality matching UFC 3-250-04 parameters to prevent slab cracking, settling, or shifting.

· Panel Mounting Capacity: Framing designed to securely and seamlessly affix twelve (12) factory-coated aluminum panels (4' x 8' dimensions, 1/4" thickness) with zero structural warping. See Figure 1 for further dimensional details.

· Wind Loading: Structural framing and foundation must be engineered to withstand regional wind loads per UFC 3-301-01 (referencing ASCE 7 structural design loads).

3. Scope of Work & Deliverables The contractor is responsible for completing all actions within the following project phases:

Submittals Submit structural drawings detailing concrete pad dimensions, reinforcing steel schedules, footing depth, and wind load compliance matching local parameters.

Construction Clear utility conflicts, excavate the designated area, prep the subgrade per UFC standards, build the formwork, place the Grade 60 steel reinforcement, and pour the 4,000 PSI concrete pad with the required 1-foot offset. Finish the concrete surface to a flat, smooth trowel finish ready for masonry work.

Procure and deliver the structural framing, mounting brackets, and hardware to the site location.

Securely install the billboard framework. Verify that the maximum ground clearance does not exceed 1 1/2 feet.

Completion Conduct final clean-up, strip concrete forms, dress the soil around the new concrete pad, and perform a joint final quality inspection with the Contracting Officer Representative.

4. Contractor Responsibilities & Quality Control

4.1 Quality Testing

The contractor must provide concrete delivery tickets verifying the mix design meets the 4,000 PSI minimum and is air entrained. Field slump and cylinder break tests may be requested by the Government inspector.

4.2 Safety Compliance

Adhere to all OSHA safety rules and Department of War based-specific industrial safety standards.

4.3 Warranty

Provide a comprehensive warranty covering concrete cracking/spalling, structural steel deformation, and foundation shifting.

Figure 1. Display Area Dimensions with Aluminum Panels image1.png