CDPS Ft Morgan - For Construction.pdf
PDF 8 MB Posted
- Attached to
- Ft Morgan WB/Scale & Pit Auth to Bid
- Solicitation number
- IFB1 RBAA 2026000145 3
- Issued by
- Otero County, Colorado
About this file
This file consists of construction plans and specifications for the Fort Morgan Colorado State Patrol Weigh Station project located at 13395 I-76 North Frontage Road, Fort Morgan, Colorado 80701. The project is under the purview of the Colorado Department of Public Safety (CDPS) and involves utility and site infrastructure work. The scope of work includes demolition of existing asphalt, concrete, and gravel surfaces; removal of trees, bushes, and foliage as directed by landscape design; removal of fencing; removal of unsatisfactory soil; removal of extra thick concrete pads around an existing scale; installation of a new truck scale with approach and departure aprons; installation of 4-inch PVC storm drainage piping approximately 103 linear feet; construction of two storm sewer cleanouts and one sand/oil interceptor; removal and replacement of concrete walkways totaling approximately 871 square feet of demolition and 655 square feet of new concrete; and removal and replacement of steps with handrails. The project is designed by HCI Engineering (Cole Haberer, P.E., #43259) with survey work by Engineering Service Company and scale manufacturing by Cardinal Scale Manufacturing Company.
The contractor is responsible for all utility location verification, obtaining necessary permits, coordinating with all utility companies and governing agencies, conducting dust control during demolition, maintaining erosion control measures including silt fence, concrete washout areas, and curb socks, and providing detailed demolition and construction plans prior to work commencement. All concrete work must comply with Colorado Department of Transportation (CDOT) standards with concrete strength per Division 600, Section 601, and concrete apron slopes not to exceed 1 percent in any direction. The contractor must schedule and perform a form and scale template check with the scale vendor prior to pouring concrete and provide written receipt of vendor approval to the engineer and state. All water, sanitary sewer, and storm sewer work must comply with appropriate governing agency standards and specifications. Class B bedding alternate and Class III reinforced concrete pipe specifications apply to storm sewer installation. The contractor bears full cost responsibility for removal, replacement, and any delays related to unverified existing conditions and damaged utilities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER
C100
XXXX
GAS GAS
WAT WAT
ELEC ELEC
OHE OHE
XXX
STORM SEWER
WATER LINE
GAS LINE
ELECTRICAL
OVERHEAD POWER LINES
ELECTRICAL BOX
SITE LIGHT
SIGN
INLET
CLEAN OUT
TREE
SLOPE
MAJOR CONTOUR
MINOR CONTOUR
SPOT ELEVATION
PROPOSED
UTILITY POLE
GAS METER
FO FOFIBER OPTIC LINE
GREASE INTERCEPTOR
MASTER LEGEND
GRADING LEGEND
FLARED END SECTION
DEMOLITION NOTES:
1. TREE REMOVAL/RELOCATION SHALL BE COORDINATED WITH LANDSCAPE PLANS AND OWNER'S
REPRESENTATIVE.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND VERIFY THE EXTENTS OF
REQUIRED DEMOLITION PRIOR TO CONSTRUCTION. ADDITIONAL SCOPE MAY BE REQUIRED
THAN SHOWN HEREON. THE CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH
STRUCTURAL MECHANICAL, ELECTRICAL, PLUMBING, LANDSCAPING AND ARCHITECTURAL
DRAWINGS.
3. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR BURIED UTILITIES. THE CONTRACTOR IS
RESPONSIBLE FOR LOCATING AND PROTECTING ALL UTILITIES PRIOR TO CONSTRUCTION.
4. THESE PLANS ARE BASED ON THE SURVEY BY ENGINEERING SERVICE COMPANY, DATED
01/21/2026. HCI ENGINEERING HAS NOT CONDUCTED ANY ON SITE INVESTIGATION FOR
EXISTING UTILITIES. ADDITIONAL UTILITIES, IN USE OR ABANDONED, MIGHT EXIST ON, NEAR OR
CROSSING THE SUBJECT PROPERTY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONDUCT
ON SITE INVESTIGATION FOR UNKNOWN UTILITIES AND CONFIRM UTILITY LOCATIONS SHOWN
HEREON. THE CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCY.
5. CONTRACTOR SHALL PRESERVE EXISTING VEGETATION OUTSIDE OF THE PROJECT LIMITS.
ANY DAMAGE TO VEGETATION OR SITE IMPROVEMENTS OUTSIDE OF THE PROJECT LIMITS DUE
TO CONSTRUCTION ACTIVITIES SHALL BE REPLACED IN KIND AT THE CONTRACTOR'S EXPENSE.
6. BARRIERS/FENCING SHALL BE PROVIDED PRIOR TO SITE DEMOLITION TO PROVIDE FOR
SAFETY OF WORKERS AND PASSERSBY. THE CONTRACTOR SHALL MAINTAIN PEDESTRIAN
ROUTES DURING CONSTRUCTION.
7. THE CONTRACTOR SHALL SUBMIT A DETAIL DEMOLITION PLAN OUTLINING REMOVAL.
8. THE CONTRACTOR SHALL PROVIDE FOR DUST CONTROL DURING DEMOLITION TO INCLUDE
COVERING TRUCKS HAULING DEBRIS OFFSITE, PERIODICALLY CLEANING AND SWEEPING
ADJACENT STREETS AND DRIVES AND/OR USING DUST PALLIATIVE AS NEEDED.
9. THE CONTRACTOR SHALL SAW CUT EXISTING ASPHALT PAVEMENT AT DEMOLITION LIMITS.
APPLY SS-1 TACKCOAT AT EDGE PRIOR TO PLACING NEW ASPHALT.
10. EXISTING CONCRETE AT DEMOLITION LIMITS SHALL BE SCORED THEN BROKEN AT THE JOINT
TO CREATE A ROUGH SURFACE TO ACCEPT NEW CONCRETE.
11. THE CONTRACTOR SHALL REFER TO PROJECT SPECIFICATIONS FOR THE DISPOSAL OF ALL
DEMOLISHED ITEMS.
12. THOROUGHLY CLEAN ALL AREAS, SURFACES, BUILDINGS AND STRUCTURES IMPACTED BY
DEMOLITION ACTIVITIES PRIOR TO START OF NEW CONSTRUCTION.
13. DEMOLITION SHALL INCLUDE (AT A MINIMUM):
· REMOVAL OF ASPHALT, CONCRETE, AND OR GRAVEL SURFACES.
· REMOVAL OR TREES, BUSHES AND FOLIAGE, AS DIRECTED BY LANDSCAPE. TREE REMOVAL
OR TRANSPLANTING SHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE AND
LANDSCAPE.
· REMOVAL OF FENCE.
· REMOVAL OF ANY UNSATISFACTORY SOIL, AS IDENTIFIED BY THE GEOTECHNICAL
ENGINEER.
14. CONTRACTOR SHALL PROVIDE FOR REMOVAL OF EXTRA THICK CONCRETE PADS AROUND THE
EXISTING SCALE.
HCI GENERAL UTILITY NOTES:
1. ALL WATER, SANITARY SEWER AND STORM SEWER WORK SHALL COMPLY WITH THE
APPROPRIATE GOVERNING AGENCIES' STANDARDS AND SPECIFICATIONS, CURRENT EDITION,
PERTINENT TO EACH UTILITY.
2. THE CONTRACTOR AND SURVEY CREW SHALL VERIFY ELEVATIONS OF EXISTING SANITARY
SEWER, STORM SEWER, WATER LINES AND MANHOLES TO BE TIED TO PRIOR TO
CONSTRUCTION OR STAKING OF PIPE. THE CONTRACTOR SHALL NOTIFY ENGINEER OF ANY
DISCREPANCY.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET
OF RECORD DRAWINGS.
4. THE CONTRACTOR SHALL CONTACT ALL APPROPRIATE UTILITY COMPANIES AND THE
APPROPRIATE GOVERNING AGENCY PRIOR TO THE BEGINNING OF ANY CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ANY EXISTING UTILITY (INCLUDING
DEPTHS) WHICH MAY CONFLICT WITH THE PROPOSED CONSTRUCTION. ALL EXISTING UTILITIES
SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR. DAMAGED UTILITIES SHALL BE
REPAIRED BY THE CONTRACTOR AT HIS OWN EXPENSE.
5. THE LOCATIONS OF EXISTING UTILITIES ARE BASED UPON THE BEST AVAILABLE INFORMATION, ARE SHOWN IN AN APPROXIMATE WAY ONLY, AND HAVE NOT BEEN INDEPENDENTLY VERIFIED
BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT
LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, AND AGREES TO BE FULLY
RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THE
CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES.
6. LOCATION OF ALL EXISTING UTILITIES (PRIVATE OR PUBLIC) SHALL BE IDENTIFIED AND VERIFIED
BY CONTRACTOR PRIOR TO MOBILIZATION, CONSTRUCTION, OR ORDERING OF MATERIALS. THE
CONTRACTOR SHALL BEAR THE FULL COST OF REMOVAL, REPLACEMENT AND DELAY RELATED
TO UNVERIFIED EXISTING CONDITIONS. WHERE THE CONTRACTOR FINDS CONFLICTS OR
DISCREPANCIES THEY SHALL BE REPORTED IMMEDIATELY TO THE ENGINEER.
7. THE CONTRACTOR SHALL OBTAIN, AT HIS EXPENSE, ALL PERMITS THAT ARE NECESSARY TO
PERFORM THE PROPOSED WORK.
8. PIPE BACKFILLING SHALL NOT OCCUR UNTIL PIPE HAS BEEN INSPECTED.
9. BEGIN LAYING PIPE AT THE LOWEST POINT, WITH THE BELLS POINTING UPHILL. LAY THE PIPE IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. LAY
PIPE TRUE TO LINE AND GRADE AS SHOWN ON THE DRAWINGS.
10. ALL STORM SEWER AND SANITARY SEWER PIPE LENGTHS AND SLOPES ARE FIGURED FROM
CENTER OF MANHOLE, BEND, WYE AND THE INSIDE WALL OF INLETS. PIPE LENGTHS ARE GIVEN
AS A HORIZONTAL LENGTH AND ARE APPROXIMATE. PIPE LENGTHS INCLUDE THE FLARED END
SECTION.
11. ALL STORM SEWER AND SANITARY SEWER PIPE BEDDING TO BE CLASS B BEDDING ALTERNATE, UNLESS OTHERWISE NOTED.
12. RCP STORM SEWER PIPE SHALL BE CLASS III, UNLESS OTHERWISE NOTED.
13. ALL RCP SECTIONS SHALL BE JOINED IN SUCH A MANNER THAT THE ENDS ARE FULLY ENTERED
AND THE INNER SURFACES ARE REASONABLY FLUSH. RUBBER GASKETS SHALL BE USED ON
ALL PIPE JOINTS CONFORMING TO ASTM C-433. AVERAGE JOINT GAP THAT EXCEEDS ½ INCH
SHALL BE FILLED WITH AN APPROVED FLEXIBLE PLASTIC SEALANT.
14. PVC STORM SEWER PIPES AND SANITARY MAIN / SERVICES SHALL CONFORM TO ASTM D3034 SDR 35 FOR SIZES 4-INCHES TO 15-INCHES IN DIAMETER (SOLID WALL), UNLESS OTHERWISE
NOTED. GASKETS SHALL COMPLY WITH ASTM F477, CONSISTING OF A PROPERLY VULCANIZED
HIGH GRADE ELASTOMERIC COMPOUND. LUBRICANTS SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS. JOINTS SHALL BE IN CONFORMANCE WITH ASTM D3212.
C900 PIPE USED FOR STORM SEWER CONSTRUCTION SHALL BE DR18.
15. CONSTRUCTION AND MATERIALS USED IN ALL STORM SEWER CONSTRUCTION SHALL BE PER
THE APPROPRIATE GOVERNING AGENCIES STANDARDS. ALL MANHOLES SHALL HAVE SHAPED
INVERTS.
16. CONSTRUCTION AND MATERIALS USED IN ALL SANITARY SEWER OR WATER MAIN
CONSTRUCTION SHALL BE PER THE APPROPRIATE GOVERNING AGENCIES STANDARDS AND
SPECIFICATIONS. ALL MANHOLES SHALL HAVE SHAPED INVERTS.
17. MANHOLE RIM ELEVATIONS SHOWN ARE APPROXIMATE ONLY AND ARE NOT TO BE TAKEN AS
FINAL ELEVATIONS. RING AND COVER SHALL BE SET IN CENTERED CONCRETE RINGS WITH
RAM-NECK FOR ADJUSTMENT TO MATCH FINAL PAVEMENT ELEVATIONS.
18. SANITARY AND STORM SEWER PIPE SHALL BE CONSTRUCTED A MINIMUM OF TEN-FEET FROM
THE CENTER OF WATER LINES. EXCEPT WHERE THEY CROSS.
19. ALL WATER AND SANITARY SEWER SERVICES MUST BE INSPECTED BY THE APPROPRIATE
GOVERNING AGENCIES INSPECTOR.
20. SANITARY SEWER CLEAN OUTS SHALL BE THE SAME SIZE AS THE HOST PIPE. CLEAN OUTS TO
HAVE THREADED CAPS. COVERS TO BE TRAFFIC RATED AND FLUSH WITH FINISHED GRADE.
21. WATER SERVICE PIPING SHALL BE TYPE K COPPER, SOFT, UNLESS OTHERWISE NOTED. ALL
WATER SERVICE PIPE SHALL BE INSTALLED WITH 5.0-FT COVER TYPICAL (4.5-FT MINIMUM)
BELOW FINISHED GRADE. THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE
PLANS AND APPROVED BY APPROPRIATE GOVERNING AGENCY.
22. REFER TO LIGHTING PLAN FOR LOCATIONS OF LIGHT POLES.
23. WHERE APPROPRIATE, NEATLY SAW CUT ALL EXISTING CONCRETE AND ASPHALT, THE
PLACEMENT OF ADDITIONAL PAVING SHALL BE DONE TO A NEAT WORK LINE, SAW CUTTING A
MINIMUM OF ONE (1) FOOT. SAW CUTTING WILL NOT BE PAID FOR SEPARATELY BUT WILL BE
CONSIDERED INCIDENTAL TO THE WORK. REPAIR/REPLACE ALL DISTURBED EXISTING ITEMS
WITH LIKE MATERIALS AND THICKNESSES. ANY ASPHALT REMOVED IS TO BE REPLACED TO
MEET THE SPECIFICATIONS OF THE COLORADO DEPT OF TRANSPORTATION. EXISTING
CONCRETE PAVEMENT SHALL BE SCORED THEN BROKEN AT JOINT TO CREATE A ROUGH
SURFACE FOR THE CONSTRUCTION JOINT.
24. ALL ASPHALT WORK REQUIRING PATCHING WILL BE PERFORMED TO A NEAT WORK LINE. THE EXISTING ASPHALT SHALL BE SAW CUT. ALL ASPHALT PATCH WORK SHALL BE AT LEAST 2' WIDE
AFTER THE COMPLETION OF WORK. NEW CURB CAN BE PLACED FLUSH WITH THE EXISTING
ASPHALT IF IT IS TO A NEAT WORK LINE.
25. ALL UTILITIES ARE BASED UPON SURFACE LOCATES AND OR RECORD MAPS. ENGINEER IS NOT
RESPONSIBLE FOR INCONSISTENCIES DUE TO INACCURATE LOCATES OR RECORDS. ENGINEER
RECOMMENDS ALL UTILITIES BE POTHOLED AND FIELD SURVEYED TO VERIFY THIS
INFORMATION.
CIVIL ENGINEER:
HCI ENGINEERING
ATTN: COLE HABERER
621 SOUTHPARK DR., SUITE 1600
LITTLETON, CO 80120
PHONE: 303-979-3900 x201
SURVEYOR:
ENGINEERING SERVICE COMPANY
ATTN: JEFFREY MILLER, PLS
14190 E. EVANS AVE.
AURORA, CO 80014
PH: 303-337-1393
SCALE MANUFACTURER:
CARDINAL SCALE MANUFACTURING CO.
ATTN: ANITA CANTRELL
102 E. DAUGHERTY ST.
WEBB CITY, MO 64870
417-673-4631
VICINITY MAP
SCALE: 1"=1,500'
ENGINEERS CERTIFICATE
I HEREBY CERTIFY THAT THESE DRAWINGS WERE PREPARED BY
ME AND /OR UNDER MY SUPERVISION AND THAT I AM A LICENSED
PROFESSIONAL ENGINEER UNDER THE STATUES OF THE STATE
OF COLORADO
COLE C. HABERER, P.E. DATE
STATE OF COLORADO NO. 43259
AREA DESCRIPTION
WEIGH STATION LOCATED AT INTERSTATE 76, ADDRESS
13395 I-76 NORTH FRONTAGE RD,
FORT MORGAN, CO 80701
A PARCEL OF LAND SITUATED IN THE NORTHWEST 1/4 OF SECTION 8, TOWNSHIP 3
NORTH, RANGE 58 WEST OF THE 6TH P.M., COUNTY OF MORGAN, STATE OF COLORADO
BENCHMARK
NGS BENCHMARK POINT DESIGNATION “C 418” - FOUND STEEL ROD IN A LOGO BOX,
LOCATED AT I-76 MILEPOST 74.75 ALONG THE SOUTH FRONTAGE ROAD, 0.2 MILES EAST
OF THE WEIGH STATION, 119 FEET SOUTHEAST FROM THE CENTER LINE OF THE EAST
BOUND LANES OF I-76, 62.7 FEET SOUTHWEST FROM THE CENTER OF A GATE TO A FIELD
ROAD, 33.5 FEET SOUTHEAST FROM THE CENTER LINE OF THE FRONTAGE ROAD, 11.5
FEET SOUTHWEST FROM TELEPHONE RISER BOX NUMBER 13622, 3.9 FEET NORTHEAST
OF A POWER POLE WITH 2 GUY WIRES, 1.0 FEET NORTH OF A CARSONITE WITNESS
POST AND ABOUT 2.0 FEET BELOW THE HIGHWAY GRADE. ELEVATION: 4402.38 FEET
(NAVD 1988 DATUM).
Sheet List Table Sheet Number Sheet Title
C100 COVER
C200 UTILITY PLAN
C300 DETAILS
1 OF 1 PIT FOUNDATION PLAN
1 OF 1 TRUCK SCALE, ARMOR
1 OF 1 INTERCONNECTION ASSY. & DIAGRAM, 4 L. C. SYSTEM
*FOR REFERENCE ONLY*
1 OF 1 GROUNDING INSTRUCTIONS
*FOR REFERENCE ONLY*
REVISIONS:
Drawn By:
Sheet
Sheet Name:
No. Date: Description:
FI
LE
N
AM
E:
U
:\H C
I E ng in ee rin g
Pr oj ec ts
\2
6\
_0
- F t.
M or ga n
C D
PS
\C
AD
\P la ns
\2 6_
U til ity
P la n.
dw g
PL
O
TD
AT
E:
6-
-2
Checked By:
Date Issued:
Project No:
CALL 811 2-BUSINESS DAYS IN
ADVANCE BEFORE YOU DIG,
GRADE, OR EXCAVATE FOR THE
MARKING OF UNDERGROUND
MEMBER UTILITIES.
Know what's below, Call before you dig.
Number:
A DIVISION OF
HABERER CARPENTRY INC.
621 SOUTHPARK DR., SUITE 1600
LITTLETON CO, 80120
PHONE: (303) 979-3900
INFO@HABERERGROUP.COM
FT MORGAN WEIGH STATION
A PARCEL OF LAND SITUATED IN THE NORTHWEST 1/4 OF SECTION 8,
TOWNSHIP 3 NORTH, RANGE 58 WEST OF THE 6TH P.M.,
COUNTY OF MORGAN, STATE OF COLORADO
GJB
FT
M
O R
G A
N W
E
IG
H S
T A
T
IO
N C
O U
N T
Y O
F M
O R
G A
N
ST
A
T E
O F
C O
L O
R A
D O
CCH
HCI 26_02
2026-02-25
1 02.13.26 1ST SUB
FOR CONSTRUCTION
PIT DRAIN
N 1,336,672.78 E 3,448,061.82
4" PVC ~ 57.7 LF
CLEANOUT-1
N 1,336,694.66 E 3,448,115.17
4" P
VC
9.
LF
SAND/OIL INTERCEPTOR
N 1,336,724.03 E 3,448,118.48
CLEANOUT-2
N 1,336,731.98 E 3,448,119.37
4" PVC ~ 8.0 LF
4" P
VC
6.
LF
OUTFALL
N 1,336,748.08 E 3,448,121.18
REMOVE EXISTING
STEPS & REPLACE WITH
4 STEPS: 5.5" RISERS &
12" TREADS
& HAND RAILS
MATCH EX.
4397.74
MATCH EX.
4399.65
99.61
MATCH EX.
4399.64
MATCH EX.
4399.56
MATCH EX.
4397.81
1-STORY WOOD SHED
~173 SF
1-STORY VINYL
& STONE BUILDING
±686 SF
MATCH EX.
4399.53
99.57
REMOVE & REPLACE
CONCRETE WALK
10.00'
19.33'
10.00'14.10'
5.00' SAWCUT & PATCH
PER CDOT SPEC.S
7.68'
7.80' N=1,336,670.45 E=3,448,075.25
N=1,336,683.59 E=3,448,070.13
N=1,336,669.29 E=3,448,033.48
N=1,336,656.15 E=3,448,038.61
N=1,336,690.48 E=3,448,027.01
N=1,336,678.56 E=3,448,035.79
N=1,336,688.71 E=3,448,062.12
N=1,336,669.87 E=3,448,054.37
28.23'
PRO CONCRETE APRON;
REINFORCE WITH #4 REBAR
AT 12" O.C., BOTH WAYS
PRO SCALE; EXISTING ELECTRIC &
DATA TO BE REUSED FOR SCALE
CONNECTION TO SCALE HOUSE
*CAUTION!* UTILITY CROSSING!
CONTRACTOR TO VERIFY EXISTING UTILITY
DEPTH PRIOR TO PIPE INSTALLATION
PRO CONCRETE APRON;
REINFORCE WITH #4 REBAR
AT 12" O.C., BOTH WAYS
DOWEL TO EXISTING CONCRETE
WITH TIE BARS; #6 REBAR AT 36"
O.C. PER CDOT DETAIL M-412-1
DOWEL TO EXISTING CONCRETE
WITH TIE BARS; #6 REBAR AT 36"
O.C. PER CDOT DETAIL M-412-1
MATCH EX.
4397.46
MATCH EX.
4397.52
MATCH EX.
4397.50
MATCH EX.
4397.49
Profile View of PRO. STORM DRAIN
4390.00
4395.00
4400.00
4405.00
4390.00
4395.00
4400.00
4405.00
PIT DRAIN
STA:10+32.00
RIM:4397.55
INV OUT (E): 4395.56 (4" PVC)
CLEANOUT-1
STA:10+89.67
RIM:4397.40
INV IN (W): 4395.27 (4" PVC)
INV OUT (N): 4395.27 (4" PVC)
57.7' of 4" PVC @ 0.50% 29.5' of 4" PVC @ 0.50%
SAND/OIL INTERCEPTOR
STA:11+19.21
STRUCTURE TOP:4396.62
RIM:4397.26
INV IN (S): 4395.12 (4" PVC)
INV OUT (N): 4395.12 (4" PVC)
8.0' of 4" PVC @ 0.50%
CLEANOUT-2
STA:11+27.21
RIM:4396.92
INV IN (S): 4395.08 (4" PVC)
INV OUT (N): 4395.08 (4" PVC)
16.2' of 4" PVC @ 0.50%
OUTFALL
STA:11+43.42
RIM:4395.37
INV IN (S): 4395.00 (4" PVC)
10.00'
APRON
10.00'
APRON
N
30'20'10'0'
SCALE: 1"=10'
UTILITY PLAN
C200
MATERIAL LIST
MATERIALS QUANTITY
CONC. DEMO 871 SF
STM. CLEAN OUT 2 EA.
SAND/OIL INTERCEPTOR 1 EA.
4'' PVC PIPE 103 LF
PROPOSED CONCRETE 655 SF
#6 REBAR FOR TIE IN 76 EA.
UTILITY NOTES
1. BURY DEPTHS OF EXISTING DRY UTILITIES ARE SHOWN AS A
REFERENCE ONLY. CONTRACTOR TO VERIFY ACTUAL DEPTH PRIOR
TO CONSTRUCTION.
2. BURY DEPTH OF ALL SERVICE LINES IS NOT KNOW. CONTRACTOR FOR
VERIFY ACTUAL DEPTH PRIOR TO CONSTRUCTION.
3. CONTRACTOR TO VERIFY EXTENTS OF SEPTIC SYSTEM PRIOR TO
INSTALLATION OF THE STORM SYSTEM.
4. EXISTING ELECTRIC LINES TO THE EXISTING SCALE ARE TO REMAIN IN
PLACE AND BE REUSED WITH THE NEW SCALE.
CONCRETE NOTES
1. PROPOSED CONCRETE SHALL BE THE SAME THICKNESS AS EXISTING
SLAB WITH PSI STRENGTH IN ACCORDANCE WITH CDOT STANDARDS
DESCRIBED IN DIVISION 600 (MISCELLANEOUS CONSTRUCTION),
SECTION 601 (STRUCTURAL CONCRETE).
2. CONCRETE APRON SLOPES NOT TO EXCEED 1% IN ANY DIRECTION.
EROSION CONTROL NOTES
1. CONTRACTOR SHALL PROVIDE THE FOLLOWING EROSION CONTROL
MEASURES AROUND AND WITHIN THE SITE TO ENSURE EROSION AND
RUNOFF IS CONTROLLED.
1.1. SILT FENCE: AROUND LIMITS OF CONSTRUCTION
1.2. CONCRETE WASHOUT AREA: ONE LOCATION ON SITE
1.3. CURB SOCKS: DOWNSTREAM OF THE LIMITS OF CONSTRUCTION REVISIONS:
Drawn By:
Sheet
Sheet Name:
No. Date: Description:
FI
LE
N
AM
E:
U
:\H C
I E ng in ee rin g
Pr oj ec ts
\2
6\
_0
- F t.
M or ga n
C D
PS
\C
AD
\P la ns
\2 6_
U til ity
P la n.
TD
AT
E:
6-
-2
Checked By:
Date Issued:
Project No:
CALL 811 2-BUSINESS DAYS IN
ADVANCE BEFORE YOU DIG,
GRADE, OR EXCAVATE FOR THE
MARKING OF UNDERGROUND
MEMBER UTILITIES.
Know what's below, Call before you dig.
Number:
A DIVISION OF
HABERER CARPENTRY INC.
621 SOUTHPARK DR., SUITE 1600
LITTLETON CO, 80120
PHONE: (303) 979-3900
INFO@HABERERGROUP.COM
FT MORGAN WEIGH STATION
A PARCEL OF LAND SITUATED IN THE NORTHWEST 1/4 OF SECTION 8,
TOWNSHIP 3 NORTH, RANGE 58 WEST OF THE 6TH P.M.,
COUNTY OF MORGAN, STATE OF COLORADO
GJB
FT
M
O R
G A
N W
E
IG
H S
T A
T
IO
N C
O U
N T
Y O
F M
O R
G A
N
ST
A
T E
O F
C O
L O
R A
D O
CCH
HCI 26_02
2026-02-25
1 02.13.26 1ST SUBPRIOR TO POURING OF ANY CONCRETE,
CONTRACTOR SHALL SCHEDULE AND
PERFORM A FORM & SCALE TEMPLATE
CHECK WITH SCALE VENDOR.
PROVIDE ENGINEER & STATE WITH
WRITTEN RECEIPT OF COMPLETION
SHOWING VENDOR APPROVAL.
DETAILS
C300
NOTES:
1. CLEANOUT SHALL BE CONSTRUCTED SO THAT SURFACE LOAD WILL
NOT BE TRANSFERRED TO MAIN.
2. SERVICE LINE CLEANOUT MAY BE INSTALLED APPROXIMATELY 5 FEET
OUTSIDE THE BUILDING FOUNDATION.
3. A CLEANOUT IS REQUIRED ON ALL SERVICE LINES EVERY 100 FEET, AT
EVERY 'Y' OR AFTER A COMBINED TOTAL OF 145° OF BEND.
Scale: N.T.S.
SEWER C.O.A
4" PVC RISER PIPE
SCREW-ON WATER
TIGHT PLUG
4" 45° ELBOW
H-25 RATED LAMP
HOLE COVER
FINISHED GRADE
DRAIN LINE PER PLAN
FLOW
TOP OF PIPE
EMBEDMENT
MATERIAL
HAUNCHING
4" BEDDING
MINIMUM
NOTES:
1. EMBEDMENT MATERIAL MUST BE CLASS I (#67 OR #78M
WASHED STONE IS TYPICALLY USED).
2. EMBEDMENT MATERIAL SHALL BE COMPACTED TO A MINIMUM
95% STANDARD PROCTOR DENSITY FOR CLASS I MATERIAL.
3. STANDARD BEDDING SHALL BE UTILIZED FOR ALL CASES
WHERE TRENCH BOTTOMS ARE UNSTABLE DUE TO SOIL TYPE
OR MOISTURE CONDITIONS.
4. ALL SANITARY SEWER LINES LESS THAN 3 FEET AND OVER 30
FEET IN DEPTH MUST BE DUCTILE IRON PIPE.
STANDARD BEDDING
FOR 3' TO 14' DEPTHS
UNDISTURBED
TRENCH WALL
COMPACTED
BACK FILL
SDR 26 OR
SDR 35 PVC
PVC
Scale: N.T.S.
STANDARD BEDDING DETAILB Scale: N.T.S.
SCALE DETAILC
SCALE PLATE
SLOPE TO DRAIN
4" PVC STORM PIPE @ 0.5%
FINISHED GRADE
MAX. 1/4" : 10' SLOPE AT APPROACH
AND DEPARTURE FOR 10'
REFERENCE PIT FOUNDATION
PLANS FOR PIT DESIGN
10.00'
FINISHED GRADE
MAX. 1/4" : 10' SLOPE AT APPROACH
AND DEPARTURE FOR 10'
10.00'
NOTES:
1. CONTRACTOR TO SAW CUT EXISTING CONCRETE AS
NECESSARY FOR INSTALLATION OF PIT, AND 10'
APPROACH/DEPARTURE.
2. MATCH EXISTING CONCRETE THICKNESS WITH ANY NEW
CONCRETE. CONTRACTOR TO BUDGET 18" CONCRETE
THICKNESS.
REVISIONS:
Drawn By:
Sheet
Sheet Name:
No. Date: Description:
FI
LE
N
AM
E:
U
:\H C
I E ng in ee rin g
Pr oj ec ts
\2
6\
_0
- F t.
M or ga n
C D
PS
\C
AD
\P la ns
\2 6_
U til ity
P la n.
TD
AT
E:
6-
-2
Checked By:
Date Issued:
Project No:
CALL 811 2-BUSINESS DAYS IN
ADVANCE BEFORE YOU DIG,
GRADE, OR EXCAVATE FOR THE
MARKING OF UNDERGROUND
MEMBER UTILITIES.
Know what's below, Call before you dig.
Number:
A DIVISION OF
HABERER CARPENTRY INC.
621 SOUTHPARK DR., SUITE 1600
LITTLETON CO, 80120
PHONE: (303) 979-3900
INFO@HABERERGROUP.COM
FT MORGAN WEIGH STATION
A PARCEL OF LAND SITUATED IN THE NORTHWEST 1/4 OF SECTION 8,
TOWNSHIP 3 NORTH, RANGE 58 WEST OF THE 6TH P.M.,
COUNTY OF MORGAN, STATE OF COLORADO
GJB
FT
M
O R
G A
N W
E
IG
H S
T A
T
IO
N C
O U
N T
Y O
F M
O R
G A
N
ST
A
T E
O F
C O
L O
R A
D O
CCH
HCI 26_02
2026-02-25
1 02.13.26 1ST SUB
MIN.
R 9"
(TYP.)
R 9"
(TYP.)
9"
1'-6"
MIN.
1'-6"
(TYP.)
3' -6
2' -1
0"
2' -1
0"
LENGTH OF LANDING 5' MIN.
TOP LANDING
9"
MIN.
2' -1
0"
2" MIN.
(TYP.)
℄ POSTSTEEL HANDRAIL REQUIRED
FOR THREE OR MORE STEPS
℄ HANDRAIL
Scale: N.T.S.
STAIR & HANDRAIL DETAILD
12" TREADS
5.5" RISERS
Anita Cantrell
762575
04 19 24
GBogdanoff Image
Anita Cantrell
762575
04 19 24
| Sheets and Views |
| C100 COVER |
| C200 UTILITY PLAN |
| C300 DETAILS |
Pages 4-7
File details come from the government source that posted it. Updated .