CCGA_2706 Camden Pumps Drawings.pdf
PDF 2 MB Posted
- Attached to
- CCGA - 2706 Camden HVAC Pump Replacements
- Solicitation number
- PE-56300-RFQ-2027-000000029
- Issued by
- Barrow County, Brooklet City, Georgia
About this file
This is a set of technical drawings for the Camden Pumps project (CCGA-2706) at the College of Coastal Georgia, located at 316 Corporate Parkway in Macon, Georgia. The drawings, prepared by NBP Engineers, Inc. of Kingsland, Georgia, document mechanical and electrical work for upgrades to the heating, ventilation, and air conditioning (HVAC) systems and related infrastructure in Mechanical Room 131H and the facility's yard. The bid set, dated September 30, 2026, includes abbreviations, legends, schedules, and detailed plans for both demolition and new work. The scope encompasses removal of existing chillers, boiler pumps, chilled water pumps, tower pumps, and associated starters, along with installation of new pumps, variable frequency drives (VFDs), and combination starters. The drawings reference post-bid addendum no. 1 dated January 26, 2023, and expire on June 30, 2028, under COA# PEF000774.
The technical specifications include pump schedules detailing equipment such as chilled water supply/return pumps (SP-1 and SP-2) rated at 400 GPM, boiler pumps (BHP-1 and BHP-2) at 180 GPM, heating water pumps (HP-1 and HP-2) at 75 GPM, and tower pumps (TP-1 and TP-2) at 600 GPM, with associated horsepower, efficiency ratings, and manufacturer details. The drawings provide comprehensive piping layouts, control valve arrangements, and electrical single-line diagrams for VFD packages, indicating the coordination required between mechanical and electrical divisions. No pricing information, set-asides, incumbent contractor details, or contract term specifics are documented in these technical drawings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2706 Camden HVAC Pumps STATEMENT OF BIDDER QU.docx | DOCX document | |
| DBB_Full_Document___CCGA_2706 CAMDEN CENTER H.docx | DOCX document | |
| 2706 Camden HVAC Pumps Invitation to Bid.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX OF
DRAWINGS
TITLESHEET NO.
316 CORPORATE PARKWAY MACON, GEORGIA
NBP ENGINEERS, INC.
CONSULTANTS
Kingsland, Georgia
COLLEGE OF COASTAL GEORGIA
M301
ABBREVIATIONS, LEGENDS, & SCHEDULES - HVACM001
M002 DETAILS - HVAC
M302
09.30.2026 BID SET
LARGE SCALE - MECHANICAL ROOM 131H & YARD - DEMOLITION - HVAC
LARGE SCALE - MECHANICAL ROOM 131H & YARD - NEW WORK - HVAC
E301
E302
LARGE SCALE - MECHANICAL ROOM 131H & YARD - DEMOLITION - ELEC
LARGE SCALE - MECHANICAL ROOM 131H & YARD - NEW WORK - ELEC
Camden Pumps
CCGA-2706
SEAL
SCALE:
FILE PATH:
P:\26069\26069m001.dgn
DATE PLOTTED
DGN FILE
01-OCT-2026
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\26069\26069m001.dgn
AS SHOWN
26069
K in g s la n d
G e o rg ia
C o ll e g e o f C o a s ta l G e o rg ia
09.30.2026
WSH
LTF
WSH
B
ID
S E
T
EXPIRES: 06.30.2028
COA#PEF000774
NBP ENGINEERS, INC.
C a m d e n P u m p s
C C
G A -2
M001
CHS CHR
HWS HWR
CR
D
SPF
HTWS HTWR
DTS DTR
CHILLED WATER SUPPLY CHILLED WATER RETURN
HEATING WATER SUPPLY HEATING WATER RETURN
CONDENSER WATER SUPPLY CONDENSER WATER RETURN
CONDENSATE DRAIN
FIRE PROTECTION MAIN STANDPIPE
HIGH TEMP. SUPPLY HIGH TEMP. RETURN
DUAL TEMP. SUPPLY DUAL TEMP. RETURN
R REFRIGERANT PIPING
RL REFRIGERANT LIQUID
CONDENSATE DRAIN
CS
RS REFRIGERANT SUCTION
RG REFRIGERANT HOT GAS
HIGH PRESSURE STEAM
LOW PRESSURE STEAM
(15 PSIG. MAX)
CR CONDENSATE RETURN (LP)
PC PUMPED CONDENSATE
50#
STEAM
(PRESSURE INDICATED)
SOLENOID VALVE RELIEF VALVE
GATE VALVE WITH
3/4" HOSE END
NEEDLE VALVE
OS&Y GATE VALVE .
GAS COCK
AUTOMATIC AIR VENTAAV
GAUGE WITH COCK
BOILER DRAIN PIPE TEST PLUG
FLEX. PIPE CONN. BACKFLOW PREVENTER
MANUAL AIR VENT
STRAINER
ELBOW UP ELBOW DOWN
BRANCH OUT BOTTOM BRANCH OUT TOP
TEE OUT BOTTOM TEE OUT TOP
SCREWED UNION FLANGED UNION
PIPE CAP BLIND FLANGE
PIPE SLEEVE
CONCENTRIC REDUCER
PIPE ANCHOR
HVAC LEGEND
BALANCE VALVE
SCREWED & FLANGED
SCREWED & FLANGED
SCREWED & FLANGED
SCREWED & FLANGED
SCREWED & FLANGED
GLOBE VALVE
CHECK VALVE
2-WAY CONTROL VALVE
CONTROL VALVE
PLAN VIEW
ECCENTRIC REDUCER
GAUGE COCK
3-WAY MIXING
VALVE IN VALVE BOX
CONTROL VALVE
HPS
THERMOMETER IN WELL
SEPARABLE SOCKET WELL
LPS
PLUG VALVE
MARK SERVICE TYPE GPM
MAX. MIN.
EFF. %2
MANUFACTURERS
REMARKS
DYNAMIC MIN.
HEAD
SHUT OFF
TACO
RPM
HP B&G PATTERSONFT. H O
PUMP SCHEDULE
SCHEDULE - HVAC
LEGEND, &
ABBREVIATIONS,
1 01.26.23POST BID ADDENDUM NO. 1
SP-1
SP-2
BHP-1
BHP-2
HP-1
HP-1
BLDG CHW
BLDG CHW
BLR-1
BLR-2
BLDG HW
BLDG HW
ES
ES
VIL
VIL
VIL
VIL
3BD
3BD
3x3x7C
2x2x9.50C
3x3x7C
2x2x9.50C
4x3x9.5
3x3x7.25
2x2x9.5
4x3x9.5
3x3x7.25
2x2x9.5
4x3x9.5
3x3x7.25
2x2x9.5
4x3x9.5
3x3x7.25
2x2x9.5
60 65 1750 15 75TP-1 & 2 VT 600 12LD 1 STAGE PUMPS---- ----
MARK SERVICE TYPE GPM
MAX. MIN.
EFF. %2
LAYOUT BASIS:
REMARKS
HP B&GFT. H O
TP-1
TP-2
VT
VT
TOWER PUMP SCHEDULE
COOLING TOWER
COOLING TOWER
COOLING TOWER
APPROXIMATE
10RJMC
10RJMC
A COMPRESSED AIR
AAV AUTOMATIC AIR VENT
AF AIR FOIL
-AFF ABOVE FINISHED FLOOR
AV ACID VENT
AVD AUTOMATIC VOLUME DAMPER
AW ACID WASTE
-AC ABOVE CEILING
AH- AIR HANDLING UNIT
BBD BOILER BLOW DOWN
BE BOTTOM ELEVATION
BOL BOTTOM OF LINE (UNINSULATED)
BOD BOTTOM OF DUCT
BP- BOOSTER PUMP
BTUH BRITISH THERMAL UNIT PER HOUR
-BF BELOW FLOOR
BFP BACK FLOW PREVENTOR
C CONDUIT
CC COOLING COIL
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CR CONDENSER WATER RETURN
CS CONDENSER WATER SUPPLY
CW DOMESTIC COLD WATER
CAB CABINET FAN
CF CENTRIFICAL FAN
CFM CUBIC FEET PER MINUTE
CFP CHEMICAL FEED PUMP
CFT CHEMICAL FEED TANK
CH CABINET HEATER
CHR CHILLER
CL CENTER LINE
CO CLEANOUT
CP CHILLER PUMP
CPHB CHROME PLATED HOSE BIBB
CT COOLING TOWER
CU COPPER
CV- CONVECTOR
Cv VALVE COEFFICIENT
D DRAIN
DDC DIRECT DIGITAL CONTROL
DHW DOMESTIC HOT WATER
DN DOWN
DP DIFFERENTIAL PRESSURE
DS DOWN SPOUT
DSO DOWN SPOUT OVER FLOW
DX DIRECT EXCHANGE
EAD EXHAUST AIR DAMPER
EAT ENTERING AIR TEMPERATURE
EDB ENTERING DRY BULB
EWB ENTERING WET BULB
ESP END SUCTION PUMP
ESP EXTERNAL STATIC PRESSURE
ELL ELBOW
ET EXPANSION TANK
EQT EQUIPMENT TRAP SET
EWT ENTERING WATER TEMPERATURE
EX EXPANSION TANK LINE
EXT EXTERNAL
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
F&BP FACE & BYPASS
FC FAN COIL UNIT
BPD BYPASS DAMPER
EAL EXHAUST AIR LOUVER
ECH ELECTRIC CABINET HEATER
ABBREVIATIONS
FD FLOOR DRAIN
FF FOULING FACTOR
FF- FLY FAN
FF FINISHED FLOOR
FF FINAL FILTER
FFM FIRE FLOW METER
FLEX FLEXIBLE
FM FIRE MAIN
FMS FLOW METER STATION
FOF FUEL OIL FLOW
FOR FUEL OIL RETURN
FOV FUEL OIL VENT
FOP FUEL OIL PUMP
FP FIRE PUMP
FP- FAN POWERED
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRT FLOW RATE TRANSMITTER
FT FEET
G LOW PRESSURE GAS
GA GAUGE
GPM GALLONS PER MINUTE
GT GREASE TRAP
GTH GRAND TOTAL HEAT
H HEIGHT
HC HEATING COIL
HB HOSE BIBB
HBT HORIZONTAL BLOW THROUGH
HD HUB DRAIN
HDT HORIZONTAL DRAW THROUGH
HP HORSEPOWER/HIGH PRESSURE
HPA HIGH PRESSURE AIR
HPG HIGH PRESSURE GAS
HPS HIGH PRESSURE STEAM
HPWS HEAT PUMP WATER SUPPLY
HPWR HEAT PUMP WATER RETURN
HSC HORIZONTAL SPLIT CASE
HWG HOT WATER GENERATOR
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
ILC IN-LINE CENTRIFICAL
IT INTERVAL TIMER
IN INCHES
INV INVERT
JB JUNCTION BOX
L LENGTH
LR LONG RADIUS
LAT LEAVING AIR TEMPERATURE
LCP LOCAL CONTROL PANEL
LDB LEAVING DRY BULB
LN LIQUID NITROGEN
LWB LEAVING WET BULB
LWT LEAVING WATER TEMPERATURE
LPS LOW PRESSURE STEAM
MAV MANUAL AIR VENT
MVD MANUAL VOLUME DAMPER
MAX MAXIMUM
MBH ONE THOUSAND BTUH PER HOUR
MCC MOTOR CONTROL CENTER
MIN MINIMUM
MH MAN HOLE
MP SUMP (MUD) PUMP
MPS MEDIUM PRESSURE STEAM
MPR MEDIUM PRESSURE RETURN
MTS MEDIUM TEMPERATURE SUPPLY
MTR MEDIUM TEMPERATURE RETURN
MUA MAKE-UP AIR
MUW MAKE-UP WATER
MZ MULTIZONE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OAD OUTSIDE AIR DAMPER
ODT OUTDOOR TEMPERATURE
PC PUMP CONDENSATE
PD PRESSURE DROP
PRV PRESSURE REDUCING VALVE
PWF PROPELLER WALL FAN
R REFRIGERANT
RA RETURN AIR
RAD RETURN AIR DAMPER
RAS RELIEF AIR SUPPLY
RP RECIRCULATING PUMP
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
RD ROOF DRAIN
RV RELIEF VALVE
SR SHORT RADIUS
OAL OUTSIDE AIR LOUVER
SAN SANITARY SEWER
SC SILL COCK
SCD SMOKE DAMPER
SD STORM DRAIN
SD SMOKE DETECTOR
SF SQUARE FEET
SDO STORM DRAIN OVERFLOW
SHC SENSIBLE HEAT CAPACITY
SP STAND PIPE
SP SUMP PUMP
SPS STATIC PRESSURE SENSOR
STA STATION
TR TEMPERED WATER RETURN
UG UNDERGROUND
VAC VACUUM PIPING
VDT VERTICAL DRAW THROUGH
VTR VENT THROUGH ROOF
WB WET BULB
O2 OXYGEN
F DEGREES FAHRE C DEGREES CENTI
WM WATER METER
WL WATER LINE
WH WATER HEATER
WG WATER GAUGE
W WIDTH
W WASTE
VT VERTICAL TURBINE
VFD VARIABLE FREQUENCY DRIVE
VB VACUUM BREAKER
VAV VARIABLE AIR VOLUME
V VENT
UC UNDERCUT (DOOR - 3/4")
V- VALVE
TOS TOP OF STRUCTURE
TB THRUST BLOCK
T TEMPERED WATER
STR STRAINER
SP STATIC PRESSURE
SP SPRINKLER PIPE
SG SPECIALTY GAS
EUH ELECTRIC UNIT HEATER
RECIRCULATING
DHR DOMESTIC HOT WATER
TRANSMITTER
DPT DIFFERENTIAL PRESSURE
PER MINUTE
SCIM STANDARD CUBIC INCHES
TEMPERATURE
SST SATURATED SUCTION
(UNINSULATED)
TE TOP ELEVATION
(TOWER) PUMP
TP CONDENSER WATER
FSD FIRE/SMOKE DAMPER
EA EXHAUST AIR
MA MIXED AIR
AE ADJUSTABLE AIR EXTRACTOR
RAO RETURN AIR OPENING
AD AREA DRAIN/ACCESS DOOR
SEAL
SCALE:
FILE PATH:
P:\26069\26069m002.dgn
DATE PLOTTED
DGN FILE
01-OCT-2026
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\26069\26069m002.dgn
AS SHOWN
26069
K in g s la n d
G e o rg ia
C o ll e g e o f C o a s ta l G e o rg ia
09.30.2026
WSH
LTF
WSH
T
EXPIRES: 06.30.2028
COA#PEF000774
NBP ENGINEERS, INC.
C a m d e n P u m p s
C C
G A -2
M002
DETAILS - HVAC
BRANCH CIRCUIT FROM
PANELBOARD,SWITCHGEAR,OR MCC
(2600)
SYSTEM SHOWN IN NORMAL (VFD NOT BYPASSED)
NUMBERS IN PARENTHESES INDICATE DIVISION
UNDER WHICH WORK OR EQUIPMENT IS SPECIFIED.
NOT TO SCALE
MODE, MOTOR RUNNING.
OVERLOAD
CIRCUIT
BREAKER
VFD SINGLE LINE DIAGRAM
VFD PACKAGE
RECTIFIER AND
INVERTER
NOTES:(THIS DETAIL ONLY)
TYPICAL END SUCTION PUMP
ELEVATION
FLEXIBLE CONNECTION
FLEXIBLE COUPLING AND
COUPLING GUARD
PIPE INSULATION
PRESSURE GAUGE
TEST PLUG
‚" BALL VALVE, TYPICAL
ADJUSTABLE FOOT
FULL SIZE BLOWDOWN ‚" DRAIN
TO FLOOR DRAIN
PAN (CHILLED WATER
PUMP(S) ONLY
18 GA. S.S. DRIP
2"
1"
SUCTION DIFFUSER
WITH STRAINER
CONCRETE BASE AS SPECIFIED
BALL OR BUTTERFLY
•" DRAIN TAPPING
PIPE TO FLOOR DRAIN
CIRCUIT SETTER
NOT TO SCALE
(2600)
(2300)
MOTOR (2300)
18 GA. S.S. DRIP PAN
(CHILLED WATER PUMP(S)
ONLY)
TEST PLUGS
1/2" SCH. 40 TO DRAIN (CHILLED
WATER PUMP(S) ONLY
LIQUID TIGHT,NEOPRENE COATED
FLEXIBLE CONDUIT
RIGID CONDUIT STUB
TO 3" ABOVE BASE
CONCRETE BASE
AS SPECIFIED
BEVEL
4"
4" 4"
NOT TO SCALE
END SUCTION PUMP
PLAN
WALL
AS SYSTEM PIPE.
MANUAL AIR VENT
TERMINATE DRAIN WITH HOSE END
CONNECTION 18" ABOVE FLOOR.
WHERE AIR VENTS OCCUR ABOVE ACCESSIBLE
CEILING. LOCATE VALVE AND TERMINATE DRAIN
HERE, UNLESS NOTED OTHERWISE AND POSITION
VALVE FOR VERTICAL DOWN DISCHARGE.
•" PIPE SAME MATERIAL
2•"
VERTICAL
PIPE
SUPPORT
WELDED PIPETHREADED / BRAISED
PIPING
BALL VALVE (EXPOSED) OR
GATE VALVE (CONCEALED)
ARRANGEMENT FOR LOCATIONS
WITH LIMITED CLEARANCE
6"MAX.
NOT TO SCALE
UPCONC. LOADING DOCK
MECHANICAL
ROOM
131H
PLAN
ROOM
131G
TOILET
131J
ELECTRICAL
ROOM
131I
46 47 48 49
R
S
T
Q
U
SEAL
SCALE:
FILE PATH:
P:\26069\26069m301.dgn
DATE PLOTTED
DGN FILE
01-OCT-2026
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\26069\26069m301.dgn
AS SHOWN
26069
K in g s la n d
G e o rg ia
C o ll e g e o f C o a s ta l G e o rg ia
09.30.2026
WSH
LTF
WSH
T
EXPIRES: 06.30.2028
COA#PEF000774
NBP ENGINEERS, INC.
C a m d e n P u m p s
C C
G A -2
M301
SCALE:
= 1'-0
4 0 2 4 8
6"
6"
CHR-1
REFRIGERANT MONITOR
EXISTING FAN SF-4
INTERLOCK WITH
CHR-2
6"
6"
BLR-1
WH
FUTURE CHILLERCP-1SP-1
FUT. CP
VFD-3
AH-4
T
SAF-4
UH-1
FILTER F-3
10"{
EF-12
EF-13
T
G
T
225KVA
T
30KVA
HLS
ATS-Q
ES
HX
C
HGQ
B
A
MAIN
LX
LM
LGQ
HX
XLGQ
XLM
EXISTING PIPES-IN
CAP ON ROOF
16"{ UP TO
FD
AP
FM
FM
FM
FM
3"
3"DN
M U
W
MUW
B.E. @12'0"
FRT
6" DN
6" DN
PLG.
GAS IN
AP
FD
P L
U M
B
IN
G
F P
SD
FD
24"x16" OPENING w/FD
C H S
C H
R
C S
C S
C R
C S
C R
H W
S
H W
R
R V
R V
C S
C S
C R
"H
W S
2" CHR
2" CHS
4"HWR
4"HWS
8"CHR
"C
H R
"C
H S
H W
R
6"CHS
8"CHR
"C
H S
GAS METER
T UH-1
SAF-4
PURGE SWITCH
EXISTING MANUAL
REFRIGERANT LEAK INDICATOR
EXISTING SURFACE MOUNTED REMOTE
RA
36/18 RA
SEE FIRE
C H S
CP-2
ATS-LS
SWITCHBOARD
MAIN
LINE LEGEND
EXISTING TO REMAIN
DEMOLITION
EXISTING
EXISTING
ACP-CH/HW
STARTERS(2)
STACKED
METAL PLENUM
LOUVER w/12" DEEP
EXISTING 24"x24"
CR
OAL ABOVE DOOR
EXISTING 72"X42"
EXISTING
EXISTINGEXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
BLR-2
CONC. PAD
EXISTING
EXISTING HW BYPASS FEED
CT CHEM TREAT
EXISTING
EXISTING
EXPANSION TANK
EXISTING CHW
EXISTING CH BYPASS FEED
OA DUCT
EXISTING 12"{
EXISTING MVD
EXISTING
EXISTING
EXISTING HW EXPANSION TANK
EXISTING STARTER
REMOVE CHW PUMP SP-1
REMOVE EXISTING
CHW PUMP SP-2
REMOVE EXISTING
EXISTING AIR SEPARATOR
REMOVE EXISTING COMBINATION STARTERS
HP-1 & 2HW PUMPS
REMOVE EXISTING
BHP-1 & BHP-2
BOILER PUMPS
REMOVE EXISTING
H W
S
H W
R
COMBINATION STARTERS
TOWER PUMP
REMOVE EXISTING
CT-2
CT-1
6"CR
6"CR
"C
R "C
R
C R
CONC. SUMP
EXISTING
VFD-4
SUPPORT
2"{ PIPE
LARGE SCALE - MECHANICAL ROOM 131 H & YARD - DEMOLITION - HVAC
TOWER PUMP TP-2
REMOVE EXISTING
TOWER PUMP TP-1
REMOVE EXISTING
DEMOLITION - HVAC
ROOM 131H & YARD-
MECHANICAL
LARGE SCALE -
UPCONC. LOADING DOCK
MECHANICAL
ROOM
131H
PLAN
ROOM
131G
TOILET
131J
ELECTRICAL
ROOM
131I
46 47 48 49
R
S
T
Q
U
SEAL
SCALE:
FILE PATH:
P:\26069\26069m302.dgn
DATE PLOTTED
DGN FILE
01-OCT-2026
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\26069\26069m302.dgn
AS SHOWN
26069
K in g s la n d
G e o rg ia
C o ll e g e o f C o a s ta l G e o rg ia
09.30.2026
WSH
LTF
WSH
T
EXPIRES: 06.30.2028
COA#PEF000774
NBP ENGINEERS, INC.
C a m d e n P u m p s
C C
G A -2
6"
6"
CHR-1
REFRIGERANT MONITORCHR-2
6"
6"
BLR-1
WH
FUTURE CHILLERCP-1
FUT. CP
VFD-3
AH-4
T
SAF-4
UH-1
FILTER F-3
10"{
EF-12
EF-13
T
G
T
225KVA
T
30KVA
HLS
ATS-Q
ES
HX
C
HGQ
B
A
MAIN
LX
LM
LGQ
HX
XLGQ
XLM
EXISTING PIPES-IN
CAP ON ROOF
16"{ UP TO
FD
AP
FM
FM
FM
FM
3"
3"DN
M U
W
MUW
B.E. @12'0"
FRT
6" DN
PLG.
GAS IN
AP
FD
P L
U M
B
IN
G
F P
SD
FD
24"x16" OPENING w/FD
C H S
C H
R
C S
C S
C R
C S
C R
H W
S
H W
R
R V
R V
C S
C S
C R
"H
W S
2" CHR
2" CHS
4"HWR
4"HWS
8"CHR
"C
H R
"C
H S
H W
R
6"CHS
8"CHR
"C
H S
GAS METER
T UH-1
SAF-4
PURGE SWITCH
EXISTING MANUAL
REFRIGERANT LEAK INDICATOR
EXISTING SURFACE MOUNTED REMOTE
RA
36/18 RA
SEE FIRE
C H S
CP-2
ATS-LS
SWITCHBOARD
MAIN
EXISTING
EXISTING
ACP-CH/HW
STARTERS(2)
STACKED
METAL PLENUM
LOUVER w/12" DEEP
EXISTING 24"x24"
CR
OAL ABOVE DOOR
EXISTING 72"X42"
EXISTING
EXISTINGEXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
BLR-2
CONC. PAD
EXISTING
EXISTING HW BYPASS FEED
CT CHEM TREAT
EXISTING
EXISTING
EXPANSION TANK
EXISTING CHW
EXISTING CH BYPASS FEED
OA DUCT
EXISTING 12"{
EXISTING MVD
EXISTING
EXISTING
EXISTING HW EXPANSION TANK
EXISTING AIR SEPARATOR
H W
S
H W
R
CT-2
CT-1
6"CR
6"CR
"C
R "C
R
C R
CONC. SUMP
EXISTING
VFD-4
SUPPORT
2"{ PIPE
M302
SCALE:
= 1'-0
4 0 2 4 8
LARGE SCALE - MECHANICAL ROOM 131 H & YARD - NEW WORK - HVAC
NEW WORK - HVAC
ROOM 131H & YARD -
MECHANICAL
LARGE SCALE -
LINE LEGEND
POINT OF CONNECTION
EXISTING TO REMAIN
NEW WORK
PUMP TP-2
NEW TOWER
PUMP TP-1
NEW TOWER
FOR TOWER PUMPS
STARTERS/DISCONNECTS
COMBINATION
PROVIDE NEW
HP-1 & 2NEW
STACKED
BHP-1 & BHP-2
NEW BOILER PUMPS
NEW COMBINATION STARTERS FOR NEW PUMPS
PUMP SP-2
NEW CHW
PUMP SP-1
NEW CHW
NEW VFD'S
UPCONC. LOADING DOCK
MECHANICAL
ROOM
131H
PLAN
ROOM
131G
TOILET
131J
ELECTRICAL
ROOM
131I
46 47 48 49
R
S
T
Q
U
SEAL
SCALE:
FILE PATH:
P:\26069\26069e301.dgn
DATE PLOTTED
DGN FILE
01-OCT-2026
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\26069\26069e301.dgn
AS SHOWN
26069
K in g s la n d
G e o rg ia
C o ll e g e o f C o a s ta l G e o rg ia
09.30.2026
SHD
BCO
SHD
T
EXPIRES: 06.30.2028
COA#PEF000774
NBP ENGINEERS, INC.
C a m d e n P u m p s
C C
G A -2
E301
CHR-1
REFRIGERANT MONITORCHR-2
BLR-1
WH
FUTURE CHILLER
FUT. CP
VFD-3
AH-4
SAF-4
UH-1
EF-12
EF-13
G
T
225KVA
T
30KVA
HLS
ATS-Q
ES
HX
C
HGQ
B
A
MAIN
LX
LM
LGQ
HX
XLGQ
XLM
GAS IN
P L
U M
B
IN
G
F P
GAS METER
REFRIGERANT LEAK INDICATOR
EXISTING SURFACE MOUNTED REMOTE
SEE FIRE
CP-2
ATS-LS
SWITCHBOARD
MAIN
LINE LEGEND
EXISTING TO REMAIN
DEMOLITION
EXISTING
EXISTING
ACP-CH/HW
EXISTING
EXISTINGEXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
BLR-2
EXISTING
CP-1
EXISTING
EXISTING CT CHEM. TREAT
EXPANSION TANK
EXISTING HW
EXISTING
EXISTING CH BYPASS FEED
EXPANSION TANK
EXISTING CHW
EXISTING
SCALE:
= 1'-0
4 0 2 4 8
LARGE SCALE - MECHANICAL ROOM 131 H & YARD - DEMOLITION - ELEC
CT-2
CT-1
CONC. SUMP
COMBINATION STARTERS
TOWER PUMP
REMOVE EXISTING
VFD-4
EXISTING
EXISTING HW BYPASS FEED
REMOVE EXISTING COMBINATION STARTERS
HP-1 & 2HW PUMPS
REMOVE EXISTING
BHP-1 & BHP-2
BOILER PUMPS
REMOVE EXISTING
CHW PUMP SP-1
REMOVE EXISTING
PURGE SWITCH
EXISTING MANUAL
STARTERS(2)
STACKED
EXISTING
CHW PUMP SP-2
REMOVE EXISTING
CONC. PAD
EXISTING
EXISTING STARTER
REMOVE
TOWER PUMP TP-2
REMOVE EXISTING
TOWER PUMP TP-1
REMOVE EXISTING
DEMOLITION - ELEC
ROOM 131H & YARD-
UPCONC. LOADING DOCK
MECHANICAL
ROOM
131H
PLAN
ROOM
131G
TOILET
131J
ELECTRICAL
ROOM
131I
46 47 48 49
R
S
T
Q
U
SEAL
SCALE:
FILE PATH:
P:\26069\26069e302.dgn
DATE PLOTTED
DGN FILE
01-OCT-2026
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\26069\26069e302.dgn
AS SHOWN
26069
K in g s la n d
G e o rg ia
C o ll e g e o f C o a s ta l G e o rg ia
09.30.2026
SHD
BCO
SHD
T
EXPIRES: 06.30.2028
COA#PEF000774
NBP ENGINEERS, INC.
C a m d e n P u m p s
C C
G A -2
CHR-1
REFRIGERANT MONITORCHR-2
BLR-1
WH
FUTURE CHILLER
FUT. CP
VFD-3
AH-4
SAF-4
UH-1
EF-12
EF-13
G
T
225KVA
T
30KVA
HLS
ATS-Q
ES
HX
C
HGQ
B
A
MAIN
LX
LM
LGQ
HX
XLGQ
XLM
GAS IN
P L
U M
B
IN
G
F P
GAS METER
REFRIGERANT LEAK INDICATOR
EXISTING SURFACE MOUNTED REMOTE
SEE FIRE
CP-2
ATS-LS
SWITCHBOARD
MAIN
EXISTING
EXISTING
ACP-CH/HW
EXISTING
EXISTINGEXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
BLR-2
EXISTING
CP-1
EXISTING
EXISTING CT CHEM. TREAT
EXPANSION TANK
EXISTING HW
EXISTING
EXISTING CH BYPASS FEED
EXPANSION TANK
EXISTING CHW
EXISTING
CT-2
CT-1
CONC. SUMP
VFD-4
EXISTING
EXISTING HW BYPASS FEED
PURGE SWITCH
EXISTING MANUAL
STARTERS(2)
STACKED
EXISTING
CONC. PAD
EXISTING
PUMP TP-2
NEW TOWER
PUMP TP-1
NEW TOWER
FOR TOWER PUMPS
STARTERS/DISCONNECTS
COMBINATION
PROVIDE NEW
HP-1 & 2NEW
STACKED
BHP-1 & BHP-2
NEW BOILER PUMPS
NEW COMBINATION STARTERS FOR NEW PUMPS
PUMP SP-2
NEW CHW
PUMP SP-1
NEW CHW
NEW VFD'S
E302
SCALE:
= 1'-0
4 0 2 4 8
LARGE SCALE - MECHANICAL ROOM 131 H & YARD - NEW WORK - ELEC
LINE LEGEND
POINT OF CONNECTION
EXISTING TO REMAIN
NEW WORK
NEW WORK - ELEC
ROOM 131H & YARD -
| 26069aCov |
| 26069m001 |
| 26069m002 |
| 26069m301 |
| 26069m302 |
| 26069e301 |
| 26069e302 |
File details come from the government source that posted it. Updated .