CASPER_MILLS_WARE_YARD_REVISED_DRAWINGS_0001.pdf

PDF 1 MB Posted

Attached to
BLM WYOMING NHTC AND MILLS WARE YARD SECURITY Federal contract opportunity
Solicitation number
140L6221R0040
Issued by
Department of the Interior Bureau of Land Management Wyoming Region

About this file

This set of construction drawings and specifications is for security system installations at the Bureau of Land Management's Casper Mills Ware Yard and National Historic Trails Interpretive Center sites in Wyoming. The solicitation seeks proposals to install access control, intrusion detection, video surveillance, and fiber optic networking systems. Key project components include installing mechanical cipher locks, 270-degree and 360-degree cameras, a network video recorder, wireless access points, a UPS, and integrating all components into a centralized security management platform. The contractor will be responsible for trenching and installing underground conduit, as well as procuring, configuring and integrating all physical security and networking equipment.

View the file

Other files for this federal contract opportunity

Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUREAU OF LAND MANAGEMENT

CASPER MILLS WARE YARD

454 DELMAR ST.

CASPER, WY 82604

BLM-MWY-01-101

01-101

SECTION - GENERAL

COVER SHEET

CASPER MILLS

WARE YARD

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

© 2017 GOOGLE© 2017 GOOGLE© 2017 GOOGLE

XX

XX

XX

GENERAL SYMBOLS

SHEET NUMBER

DETAIL NUMBER

SHEET NUMBER

ELEVATION NUMBER

SHEET NUMBER

SECTION NUMBER

DETAIL NUMBER

DETAIL DESCRIPTION

ADDITIONAL DETAIL INFORMATION

SHEET NUMBER

AREA OF INCLUSION

00-000

2c 18 AWG

NUMBER OF CONDUCTORS

GAUGE OF WIRE

FILE NUMBER DESIGNATION

XXX-XXX-XX-XXX

FACILITY DESIGNATOR

LOCATION DISCIPLINE DESIGNATOR

DRAWING TYPE DESIGNATOR

3-4 DIGIT SEQUENTIAL PAGE NUMBER

0 - GENERAL (SYMBOLS LEGEND, NOTES, ETC.)

01 COVER SHEET

02 SYMBOLS PAGE

03 ABBREVIATIONS

04 DRAWING INDEX

05 EQUIPMENT LISTS

1 - PLANS (HORIZONTAL VIEWS)

10 - PLAN VIEWS

A. OVERALL PLAN VIEWS

B. SPECIFIC BUILDING PLAN VIEWS

C. ENLARGED PLAN VIEWS

11 - ELECTRICAL & CABLING

A. PLAN VIEWS SHOWING ELECTRICAL CONDUIT RUNS

B. PLAN VIEWS SHOWING FIBER OPTIC CONDUIT RUNS

C. JUNCTION BOX LOCATIONS

D. WIRE DETAILS OF SIZE, QUANTITY

2 - ELEVATIONS (VERTICAL VIEWS)

3 - SECTIONS (SECTIONAL VIEWS)

4 - LARGE-SCALE VIEWS

(PLANS, ELEVATIONS OR SECTIONS THAT ARE NOT DETAILS)

5 - DETAILS

6 - SCHEDULES AND DIAGRAMS

60 - BLOCK DIAGRAMS

61 - ONE-LINE DIAGRAMS

62 - EQUIPMENT INTERCONNECTION DIAGRAMS

63 - WIRING DIAGRAMS NOT SPECIFIC TO EQUIPMENT

64 - TELECOMMUNICATIONS DIAGRAMS

65 - EQUIPMENT SCHEDULES

66 - PROGRAMMING SCHEDULES

67 - RACEWAY/CIRCUIT SCHEDULES

DRAWING TYPE DESIGNATOR

(PER ERDC/ITL TR-06-X; TABLE 2-3)

NOTE: PAGE NUMBER IS AN ABBREVIATED VERSION OF THE FILE NUMBER

WIRE GAUGE DESIGNATION

XX-XXX

XX-XXX

XX-XXX

1. GENERAL NOTES ON THIS SHEET APPLY TO ALL DRAWINGS.

2. LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS

ON THE SET OF DRAWINGS. ADDITIONAL LEGENDS AND/OR OTHER LEGEND SHEETS MAY

APPEAR ON SPECIFIC DRAWINGS TO INDICATE SPECIFIC CONDITIONS.

3. NEWLY INSTALLED ENCLOSURES, CABINETS, HOUSINGS, BOXES AND FITTINGS HAVING HINGED

DOORS OR REMOVABLE COVERS AND WHICH CONTAIN CIRCUITS OR CONNECTIONS OF THE

ACS SYSTEM AND ITS POWER SUPPLIES, SHALL BE PROVIDED WITH COVER OPERATED,

CORROSION RESISTANT TAMPER SWITCHES, ARRANGED TO INITIATE AN ALARM SIGNAL

WHEN THE DOOR OR COVER IS MOVED. THE ENCLOSURE AND THE TAMPER SWITCH SHALL

FUNCTION TOGETHER AND SHALL NOT ALLOW DIRECT LINE OF SIGHT TO ANY INTERNAL

COMPONENTS BEFORE THE SWITCH ACTIVATES. TAMPER SWITCHES SHALL BE

INACCESSIBLE UNTIL THE SWITCH IS ACTIVATED; HAVE MOUNTING HARDWARE

CONCEALED SO THAT THE LOCATION OF THE SWITCH CANNOT BE OBSERVED FROM THE

EXTERIOR OF THE ENCLOSURE; BE CONNECTED TO CIRCUITS WHICH ARE UNDER

ELECTRICAL SUPERVISION AT ALL TIMES, IRRESPECTIVE OF THE PROTECTION MODE IN

WHICH THE CIRCUIT IS OPERATING; SHALL BE SPRING-LOADED AND HELD IN THE

CLOSED POSITION BY THE DOOR OR COVER; AND SHALL BE WIRED SO THAT THE

CIRCUIT IS BROKEN WHEN THE DOOR OR COVER IS DISTURBED.

4. ACCESS CONTROL SYSTEM EQUIPMENT MUST BE EQUIPPED WITH CONTINUOUSLY MONITORED

TAMPER DETECTION DEVICES REGARDLESS OF WHETHER THE SYSTEM IS IN THE ACCESS OR

SECURE MODE OF OPERATION. UPON DETECTION, AN ALARM (NOT FAULT) CONDITION MUST BE

TRANSMITTED TO THE PCU OR MONITORING STATION.

5. EXACT MOUNTING LOCATION OF ACS, DAS, CCTV SHALL BE VERIFIED PRIOR TO INSTALLATION.

6. ALL EXTERIOR HOUSING ENCLOSURE BOXES SHALL BE NEMA 4X RATED.

7. CONTRACTOR SHALL INSTALL A WARNING UNDERGROUND MARKER TAPE ABOVE ALL SECURITY

UNDERGROUND DUCTBANKS. IT SHALL BE SOLID FOIL MARKER TAPE, ORANGE, 3 INCHES WIDE, DETECTABLE, NON-DEGRADABLE, CORROSION RESISTANT, TEAR RESISTANT AND WITH

1 1/4 INCH STENCILED BLACK NON-DEGRADABLE LETTERS. WORDING ON MARKERS READ

"CAUTION DUCTBANK BURIED BELOW." TRACER WIRE SHALL BE INCLUDED WITH ALL DIRECTIONAL BORING.

8. ALL FIELD DISTRIBUTION BOXES AND SECURITY EQUIPMENT CABINETS SHALL HAVE A GROUNDING

LUG OR A GROUNDING BUS BAR INSTALLED.

9. ALL COPPER WIRE TERMINATIONS SHALL HAVE AT LEAST A 3'-0" (0.91m) SERVICE

LOOP AT EACH END. ALL ESS WIRING SHALL HAVE AT LEAST 3'-0" BETWEEN A SURGE

PROTECTOR AND A DEVICE.

10. IF ANY REQUIRED INFORMATION IS NOT CONTAINED WITHIN THIS SET OF DRAWINGS, REFER TO

MANUFACTURER SUPPLIED INSTRUCTIONS.

11. THESE DRAWINGS ARE DIAGRAMITC IN NATURE AND ARE NOT INTENDED TO SHOW EXACT CONDITIONS

AS MAY EXIST UNLESS NOTED OTHERWISE.

12. DO NOT SCALE DRAWINGS AS PROVIDED SCALES ARE FOR REFERENCE ONLY.

13. THE SCALES APPLIED TO THE DRAWINGS ARE BASED OFF U.S. CUSTOMARY UNITS STANDARD.

GENERAL NOTES

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

GENERAL INFORMATION

BLM-MWY-01-002

01-002

SECTION - GENERAL

CASPER MILLS

WARE YARD

MCL

NOTE: ABBREVIATIONS LISTED ARE BASED ON INDUSTRY STANDARDS AND ALL MAY NOT BE APPLICABLE TO PROJECT.

ABBREVIATIONS SECURITY LEGEND

ALARM INTERFACE

CENTRAL PROCESSING UNIT

ELECTRONIC ENTRY CONTROL SYSTEM

HAND GEOMETRY UNIT

INTRUSION DETECTION SYSTEM

ACC/SEC

BMS

CJB

CPU

CR

ECE

EECS

HGU

IDS

DCM DOOR CONTROL MODULE

CARD READER

CU COPPER

EMT ELECTRICAL METALLIC TUBING

BALANCED MAGNETIC SWITCH

ENROLLMENT CENTER EQUIPMENT

H

DC DIRECT CURRENT

CTL CONTROL

AMP

ABOVE FINISHED FLOOR

AMPERE

EP EXPLOSION PROOF

AIF ACTIVE INFRARED SENSOR

DIB DEVICE INTERFACE BOX

CLOSED CIRCUIT TELEVISIONCCTV

CAMERA JUNCTION BOX

CTW CAMERA TOWER

DB

AFF

DP DISTRIBUTION POWER

AWG AMERICAN WIRE GAUGE

AUX

APPROX APPROXIMATELY

AUXILIARY

ADMIN ADMINISTRATOR

BLDG BUILDING

CAB

C

CABINET

COMM COMMUNICATION

DIST DISTANCE

ELECT ELECTRICAL

EQ EQUAL

EQUIP EQUIPMENT

ENCL ENCLOSURE

UNDERGROUND DUCTBANK

EHH ELECTRICAL HAND HOLE

HIGH

BAT BATTERY

BC BATTERY CHARGER

DVR DIGITAL VIDEO RECORDER

EMI ELECTROMAGNETIC INTERFERENCE

EMH

ELECTRICAL MANHOLE

CONDUIT

ERAC

BPS BYPASS SWITCH PANEL

ELEVATIONEL

FOP FIBER OPTIC DISTRIBUTION PANEL

FORX

FOT

FIBER OPTIC RECEIVER MODULE

FIBER OPTIC TRANSMISSION PANEL

GND GROUND

FDB FIELD DISTRIBUTION BOX

GALV GALVANIZED

GB GLASS BREAK

FOSC FIBER OPTIC SENSOR CABLE

(F) FUTURE

FO FIBER OPTIC

FOCC FIBER OPTIC I/O CONVERTER

GS GATE SENSOR SWITCH

GSB GATE SENSOR SWITCH JUNCTION BOX

FOB FIBER OPTIC BOX

FOSS FIBER OPTIC SENSOR SYSTEM

EXT EXTERIOR

EQUIPMENT RACK AIR CONDITIONER

FFOM FENCE FIBER OPTIC MODULE

FFOR FENCE FIBER OPTIC RACK

FOM FIBER OPTIC MODULE

FOPP FIBER OPTIC PATCH PANEL

FOR FIBER OPTIC RACK

I/O INPUT/OUTPUT

RIGID GALVANIZED STEEL

STAINLESS STEEL

RGS

SST

UPS

VM

REX

TSL TURNSTILE

SSC

TA

TAS

TROUBLE ALARM

T

TBD TO BE DETERMINED

REQ'D REQUIRED

SW SWITCH

TB TERMINAL BLOCK

W

VIDEO MONITOR

UNINTERRUPTIBLE POWER SUPPLY

TAMPER ALARM SWITCH

REQUEST TO EXIT DEVICE

V VOLTAGE

ST STRAIGHT TIP

SP SPARE

QTY QUANTITY

PR PAIR

WIDTH

PWS POWER SUPPLY ENCLOSURE

SSB SURGE SUPPRESSION BOX

TWF TAUT WIRE FENCE ALARM AREA

PP POWER PANEL

TRANSFORMER/TAMPER

UL

UNDERWRITERS LABORATORIES

TYP TYPICAL

WHT WHITE

W/ WITH

OH OVERHEAD

REC RECEIVING

SO FLEXIBLE POWER CORD

SQ SQUARE

SHH SECURITY HAND HOLE

VLS VEHICLE LOOP SENSOR

TV TELEVISION

THHN 90°, 600 VOLT NYLON JACKETED

BUILDING WIRE FOR DRY LOCATIONS

SS

SCMS SITE CONTROL AND MONITORING

SYSTEM

PNL PANEL

PTZ PAN TILT AND ZOOM

PVC POLYVINYL CHLORIDE

GATE SAFETY SENSOR

SURGE SUPPRESSOR-COAX

SSDA SURGE SUPPRESSOR-DATA

SSP SURGE SUPPRESSOR-POWER

SPDT SINGLE POLE DOUBLE THROW

SWGR SWITCHGEAR

WS WORK STATION

OSSC

PS POWER SUPPLY

SCH SCMS HUB

SCP

SCW

SCWC

SCMS PRINTER

SCMS WORKSTATION

SCMS WORKSTATION CONSOLE

LP

LOPA LOSS OF POWER ALARM

NTS NOT TO SCALE

NO

NC NORMALLY CLOSED

NORMALLY OPEN

lbs POUNDS

LED LIGHT EMITTING DIODE

LAN LOCAL AREA NETWORK

MSR MAIN SERVICE ROAD

NO. NUMBER

NOT IN CONTRACTNIC

KBD

KPD

CCTV KEYBOARD

KEYPAD

JUNCTION BOXJB

MLIB

MON

MATRIX LOOPING INPUT BAY

MECH MECHANICAL

MONITOR

CCTV ALARM INTERFACE UNITTVAI

CCTV CENTRAL PROCESSING UNITTVCP

LANU LOCAL AREA NETWORK UNIT

TP TELEPHONE DISTRIBUTION PANEL

LSI LEAD SYSTEM INTEGRATOR

SPP SECURITY POWER PANEL

VID VIDEO

LOCAL PROCESSOR

ON-SITE SUPPORT CENTER

SJB SECURITY JUNCTION BOX

HS HATCH SWITCH

HVR HIGH VOLTAGE RELAY

LCD LIQUID CRYSTAL DISPLAY

RECP RECEPTACLE

RTC REMOTE TERMINAL CONTROLLER

AS ALARM SOUNDER

ECU ELECTRIC CYLINDER UNLATCH

A:

B:

C:

D:

E:

F:

G:

H:

I:

J:

K:

L:

MBS MATRIX BAY SWITCH

M:

N:

O:

P:

Q:

R:

S:

T:

U:

V:

W:

TIC TELEPHONE INTERCOM

VAC VOLTAGE ALTERNATING CURRENT

VDC VOLTAGE DIRECT CURRENT

ITS INFRASTRUCTURE TAMPER SWITCH

ES ELECTRIC STRIKE

BMX BISTATIC MICROWAVE TRANSMITTER

BMR BISTATIC MICROWAVE RECEIVER

MS MAGNETIC SWITCH

SDR SECURITY DOOR/GATE

CAM CAMERA

OPR GATE OPERATOR

DT DUAL TECHNOLOGY MOTION SENSOR

DS DURESS SWITCH

HEAT DETECTORHD

PREX PUSH-ACTIVATED REQUEST TO EXIT

STR STROBE

HORNHRN

PB PUSH BUTTON

MAG ELECTROMAGNETIC LOCK

HWS HORN WITH STROBE

MIC MICROPHONE

FAK FIRE ALARM KEYPAD

SD SMOKE DETECTOR

PIR PASSIVE INFRARED

MM MONOSTATIC MICROWAVE

SM SINGLE MODE FIBER OPTIC

SEC SECURITY EQUIPMENT CABINET

WAP WIRELESS ACCESS POINT

CPL CAMERA POLE

CAS FIBER OPTIC CASSETTE

EX EXISTING

WDS WIRELESS DURESS SWITCH

AN ANNUNCIATOR

DPS DOOR POSITION SWITCH

ACCESS CONTROL MODULEACM

IR INFRARED

HPB HANDICAP PUSH BUTTON

INTERCOMINT

DAS DURESS ALARM SYSTEM

DPDT DOUBLE POLE DOUBLE THROW

ECB ELECTRIC CRASH BAR

EML ELECTRIC MORTISE LOCK

FOPC FIBER OPTIC PATCH CASSETTE

FIELD OF VIEW

FOTC

FOTX

FOV

FIBER OPTIC TRANSCEIVER MODULE

FIBER OPTIC TRANSMITTER MODULE

FEETFT

F CONTINUED:

GCM GENERAL CONTROL MODULE

INTERCOM MASTERINT/M

INTERMEDIATE METALLIC CONDUIT IMC

NVR NETWORK VIDEO RECORDER

SPST SINGLE POLE SINGLE THROW

FJB FIBER OPTIC JUNCTION BOX

HH HAND HOLE

MCB MECHANICAL CRASH BAR

MCL MECHANICAL CIPHER LOCK

PUSH BUTTON

CARD READER

CONTACTLESS CARD READER W/ KEYPAD

REQUEST TO EXIT

INTERCOM

ELECTRIC STRIKE

ELECTROMAGNETIC LOCK

ACCESS CONTROL PANEL

DURESS SYSTEM

EQUIPMENT GROUND

STROBE

POLE

NORTH ARROWS

UNINTERRUPTABLE POWER SUPPLY

ACS

FIXED CAMERA

DIGITAL 180° FIXED CAMERA

DIGITAL 270° FIXED CAMERA

WIRELESS ACCESS POINT

CCTV

IDS

ALARM KEYPAD

(ALARM INTERFACE)

DOOR POSITION SWITCH

WIDE GAP

DURESS SWITCH

CHAIN LINK FENCE

GENERAL SYMBOLS

DOOR POSITION SWITCH

ELECTRICALLY OPERATED CRASH BAR

REFERENCED NOTE

DETAIL REFERENCE

XX-XXX

UPS

ECB

MAG

K

N

BALANCED MAGNETIC SWITCH

UL LEVEL 2, HIGH SECURITY

HS

BALANCED MAGNETIC SWITCH

ES

S

CONTACT/CONTACTLESS CARD READER W/ KEYPAD

K

C/CL

MECHANICAL CIPHER LOCK

W

180 DEGREE

270 DEGREE

D

360° FISH EYE CAMERA

ACP

DURESS

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

ABBREVIATIONS &

SECURITY LEGEND

BLM-MWY-01-003

01-003

SECTION - GENERAL

DRAWING INDEXDRAWING INDEX

GENERAL SHEET #

BLM-MWY-01-101 COVER SHEET 01 OF 08

BLM-MWY-01-102 GENERAL INFORMATION 02 OF 08

BLM-MWY-01-103 ABBREVIATIONS AND SECURITY LEGEND 03 OF 08

BLM-MWY-01-104 DRAWING INDEX 04 OF 08

BLM-MWY-01-105 EQUIPMENT LIST 05 OF 08

PLANS SHEET #

BLM-MWY-10-001 CASPER MILLS WARE YARD SITE REFERENCE PLAN 06 OF 08

BLM-MWY-10-002 CASPER MILLS WARE YARD SITE PLAN WITH CCTV FOV(S) 07 OF 08

BLM-MWY-10-101 CASPER MILLS WARE YARD MAIN SHOP WITH CCTV AND DEVICE LOCATIONS 08 OF 08

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

DRAWING INDEX

BLM-MWY-01-004

01-004

SECTION - GENERAL

EQUIPMENT LIST

NOTE: EQUIPMENT LISTED REPRESENTS PRIMARY COMPONENTS ONLY AND IS NOT AN ALL INCLUSIVE LIST FOR A FULLY FUNCTIONING SYSTEM.

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

EQUIPMENT LIST

BLM-MWY-01-005

01-105

SECTION - GENERAL

X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X

X

X X

X X

X X

X X

X X

X

X X

X X

X X

X X

X X

X X

X X

X X X X X X X X X X X X X X X

X X X X X X X X X X X

A1

10-101

FLOOR PLAN

EXISTING

OUTBUILDING

EXISTING

OUTBUILDING

EXISTING MANUAL

VEHICLE GATE

MAIN SHOP

C O

N N

I E

T R

E E

T

DELMAR STREET

P E

N D

E L

L

B

L V

D

E X

I S

T I N

G

S

I D

E W

A L

K

EXISTING FENCE, TYP.

EXISTING UTILITY POLE, TYP.

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

BLM-MWY-10-001

10-001

SECTION - PLANS

CASPER MILLS WARE

YARD SITE REFERENCE

PLAN

N

CASPER MILLS

WARE YARD

08SITE REFERENCE PLAN

A1

SCALE: 1" = 30'

0'-0" 30'-0"

X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X

X

X X

X X

X X

X X

X X

X

X X

X X

X X

X X

X X

X X

X X

X X X X X X X X X X X X X X X

X X X X X X X X X X X

X

X

X

X

A1

10-101

FLOOR PLAN

EXISTING

OUTBUILDING

EXISTING

OUTBUILDING

EXISTING MANUAL

VEHICLE GATE

EXISTING MANUAL

VEHICLE GATE

MAIN SHOP

C O

N N

I E

T R

E E

T

DELMAR STREET

P E

N D

E L

L

B

L V

D

E X

I S

T I N

G

S

I D

E W

A L

K

EXISTING FENCE, TYP.

EXISTING UTILITY POLE, TYP.

270 DEGREE

270 DEGREE

FISHEYE

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

BLM-MWY-10-002

10-002

SECTION - PLANS

CASPER MILLS WARE

YARD SITE PLAN WITH

CCTV FOV(S)

N

CASPER MILLS

WARE YARD

A1

SCALE: 1" = 30'

0'-0" 30'-0"

MCLMCL

MAIN SHOP

UPS

NVR

CAM-103

CAM-102

EXISTING UTILITY POLE

WARE YARD

MCL

CAM-104

270 DEGREE

270 DEGREE

270 DEGREE

FISHEYE

BLM-MWY-10-101

10-101

SECTION - PLANS

CASPER MILLS WARE

YARD MAIN SHOP WITH

CCTV AND DEVICE

LOCATIONS

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JUNE 29, 2020

6-29-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

CASPER MILLS

WARE YARD

N

FLOOR PLAN W/ DEVICES

A1

0'-0" 8'-0"

SCALE: 1/8" = 1'

EQUIPMENT REFERENCE CHART

WIRING DETIALSSYMBOL

EQUIPMENT REFERENCE CHART

COMPONENT

MCL

N/A

CAT6 PLENUM

A1/51-104

NVR

E1/54-102

GENERAL EQUIPMENT NOTES:

1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.

2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.

3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.

NOTES:

INSTALL NEW NVR FOR THE NEW CCTV SYSTEM. EXACT LOCATION TO BE DETERMINED BY

AUTHORIZED ON-SITE PERSONNEL.

CONTRACTOR TO PROCURE AND INSTALL A NEW UPS THAT IS CAPABLE OF SUPPLYING

POWER TO THE ACCESS CONTROL SYSTEM, DURESS SYSTEM AND THE CCTV SYSTEM FOR

A MINIMUM OF 30 MINUTES.

INSTALL A NEW EXTERIOR 270 DEGREE CAMERA WITH A BUILT IN IR ILLUMINATOR AND

INTEGRATE INTO THE NEW CCTV SYSTEM. THE CAMERA THAT IS MOUNTED ON THE POLE IN

THE YARD WILL REQUIRE TRENCHING AND UNDERGROUND CONDUIT.

INSTALL NEW MECHANICAL CIPHER-LOCK.

INSTALL NEW WIRELESS RADIOS FOR COMMUNICATION BETWEEN REMOTE CAMERAS

AND THE MAIN SHOP.

INSTALL MONITOR FOR CCTV SUPERVISION. EXACT LOCATION TO BE DETERMINED BY

AUTHORIZED ON-SITE PERSONNEL.

INSTALL A NEW 360 DEGREE FISHEYE CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.

A1/53-104

CAT6 PLENUM

A1/51-101

MECHANICAL CIPHER-LOCK

NETWORK VIDEO RECORDER

270 DEGREE CAMERA

360 DEGREE FISH EYE CAMERA

270 DEGREE

D1/51-105

CCTV MONITOR

HDMI

FISHEYE

File details come from the government source that posted it. Updated .