CARVER_RFP_SET_(12-1-2024).pdf

PDF 3 MB Posted

Attached to
Cantonment Community Center - Premanufactured Building - RESTORE
Solicitation number
PD 24-25.108
Issued by
Escambia County, Florida

About this file

The provided file is a Request for Proposal (RFP) set of architectural and engineering design documents for the Carver Park Community Center project located at 208 Webb Street in Cantonment, Florida. The documents include comprehensive design plans for a new 6,000 square foot modular structure, with detailed drawings covering foundation, floor plan, exterior elevations, power, and lighting schemes. The project is designed as a single-story, Group A-3 (Assembly) occupancy building with a construction type of 5B (non-sprinkled), featuring spaces for a classroom, office, conference room, storage, restrooms, and a prep and serving area.

The design meets the 2023 Florida Building Code requirements across multiple disciplines, including building, mechanical, plumbing, electrical, and accessibility codes. The facility is designed to accommodate a maximum occupancy of 112 people, with specific occupancy calculations for different areas such as unconcentrated spaces, classrooms, business areas, and storage. The site plans include detailed electrical and lighting layouts, with a 400-amp main distribution panel, various receptacle types, and comprehensive lighting fixtures. The modular structure will be built on a suggested foundation with specific ventilation requirements for the crawl space, and the design emphasizes flexibility and compliance with local building and safety standards.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G001

DRAWING INDEX:

PROJECT TITLE PAGE

A101 FLOOR PLAN

SITE

SITE SCHEMATIC POWER & DATA PLANE101

SCHEMATIC LIGHTING PLANE102

EXTERIOR ELEVATIONSA201

DESIGN CRITERIA:

OCCUPANCY CLASSIFICATION:

CONSTRUCTION TYPE:

GENERAL HEIGHTS & AREAS

Area:

Height:

Stories:

6,000sf

40'

GROUP A-3 (ASSEMBLY)

5B (NON SPRINKLED)

OCCUPANCY COUNT

EGRESS

Max. allowed travel distance: 200lf Actual max. travel distance: 113lf

EXITS

Required exits: 2 Exits provided: 2

ALLOWED

4,000sf 20'-6"

DESIGN

CARVER PARK COMMUNITY CENTER

NEW MODULAR STRUCTURE & SITE

for

208 Webb Street Cantonment, FL 32533

DWG. NO.

G001

RFP

2023 FBC-B (8th ed.)BUILDING CODE:

MECHANICAL CODE:

PLUMBING CODE:

LIFE SAFETY:

CODE SUMMARY:

ENERGY EFFICIENCY CODE

2023 FBC-P (8th ed.)

2023 FBC-EC (8th ed.)

2023 FFPC (8th ed.)

ELECTRICAL CODE: 2020 NFPA 70 NEC

2023 FBC-M (8th ed.)

ACCESSIBILITY CODE: 2023 FBC-A (8th ed.)

2021 NFPA 1 & 101

SH

EE

T S

IZE

: 2 2x

12/1/2024

S101 SCHEMATIC FOUNDATION PLAN

UNCONCENTRATED (1,500sf/15net) 100 Max. Occ.

CLASSROOM (160sf/20net) 8 Max. Occ.

BUSINESS (350sf/150gross) 3 Max. Occ.

STORAGE (125sf/300gross) 1 Max. Occ.

(112 Total Occ.)

8 LANDSCAPE PLAN

7 GRADING PLAN

6 SITE AND UTILITY PLAN

5 DEMO PLAN

4 EXISTING CONDITIONS

3 STORMWATER POLLUTION PREVENTION PLAN

2 GENERAL NOTES

1 CE TITLE PAGE

65'-0"

7'-258" 7'-258" 7'-258" 7'-258" 7'-258" 7'-258" 7'-258" 7'-258" 7'-258"

'-0

'-0

'-0

'-0

'-0

2'- 0"

2'- 0"

2'- 0"

2'- 0"

2'- 0"

2'-0"

C

AR

VE

R

PA

RK

C O

M M

UN

ITY

C

EN

TE

R

W eb b St

, C an to nm en t, FL

N ew

M od ul ar

: 8 5 0 - 7 1 2 - 6 5 7 1 :

scott@deandesignbuild.com b u i l d d e s i g n d e a n i n c 2301 tobie dean road Cantonment, FL 32533

FOUNDATION PLAN1

CRAWL SPACE SKIRTING VENTILATION REQUIREMENTS

CONTRACTORS OPTION TO VENT VIA NATURAL OR MECHANICAL MEANS. ESCO

FACILITIES DEPARTMENT SHALL REVIEW METHOD PRIOR A TO INSTALLATION.

FOR NATURAL VENTILATION: THE MINIMUM COMBINED OPEN AREA IS 1SF PER 150SF OF

CRAWL SPACE AREA (VENTS MUST BE LOUVERED WITH WIRE SCREENS. SCREEN HOLES

SHALL BE NO LARGER THAN ¼”)

FOR MECHANICAL VENTILATION: THE MINIMUM VENTILATION RATE IS 0.02CFM PER 1SF

OF CRAWL SPACE AREA. (I.E.. 20CFM PER 1000SF AREA) FANS MUST BE WIRED TO

ACTIVATE WHEN HUMIDITY REACHES 60% IN THE CRAWL SPACE. PASSIVE INTAKE

LOUVERS MATCHING THE REQUIRED CFM SHALL BE INSTALLED OPPOSITE THE FANS TO

PROVIDE FOR CROSS VENTILATION. (LOUVERS SHALL HAVE WIRE SCREENS. SCREEN

HOLES SHALL BE NO LARGER THAN ¼”)

NOTES:

· THIS FOOTING DESIGN IS PRELIMINARY AND PIER LOCATIONS ARE A SUGGESTION

ONLY. FINAL DESIGN SHALL BE PROVIDED BY THE MODULAR MANUFACTURER

STRUCTURAL ENGINEER AND SUBMITTED FOR REVIEW AND ACCEPTANCE BY

ESCO FACILITIES DEPARTMENT.

· A CONTINUOUS FOOTING DESIGN IS REQUIRED.

· FOOTING WIDTHS SHALL BASED ON SITE SPECIFIC LOCATION FORCES AND A

MAX. ALLOWABLE SOIL BEARING PRESSURE OF 1,800 PSF

· NO GEOTECHNICAL REPORT HAS BEEN PROVIDED. 1,800 PSF HAS BEEN

CONSERVATIVELY ASSUMED.

S101

SU

G

G

ES

TE

D

F O

UN

D

A

TIO

N

12/1/2024

RFP

dean

A CB

65'-0"

'-0

'-0

'-0

'-0

'-0

14'-0" 7'-0" 13'-0" 31'-0"

20'-4" 10'-0" 3'-5" 16'-3" 15'-0"

2'-6" 3'-0" 7'-11 8"7'-51

4" 3'-0" 3'-0" 5' -6

32'-6" 32'-6"

5'-0" 4'-111 8"

5' -6

'-0

6'

-0

6' -0

4' -0

8'

-0

9'-6"

6' -0

3'-0"

1'-6"

3'-51 2"

'-0

REF.

PREP &

SERVING

AREAMENSWOMENS

CLASSROOM OFFICE CONFERENCE

STORAGEAC

JAN

DISCS

(B/O)

BOOKS

(B/O)

BOOK SHELVES

B/O

AC

ICE

(B/O)

FURNITURE

(B/O)

FURNITURE

(B/O)

REF

(B/O)

REF

(B/O)

DN

DN

RANGE

& HOOD

20'-0"

'-0

"45 '-0

C

AR

VE

R

PA

RK

C O

M M

UN

ITY

C

EN

TE

R

W eb b St

, C an to nm en t, FL

N ew

M od ul ar

: 8 5 0 - 7 1 2 - 6 5 7 1 :

scott@deandesignbuild.com b u i l d d e s i g n d e a n i n c 2301 tobie dean road Cantonment, FL 32533

A101

SC

HE

M A

TIC

/C

HA

RR

ET

TE

FLOOR PLAN1

12/1/2024

FLOOR PLAN

0' - 0"

TOP PLATE

9' - 0"

12345

APPROX. GROUND

-2' - 6"

FLOOR PLAN

0' - 0"

TOP PLATE

9' - 0"

1 2 3 4 5

APPROX. GROUND

-2' - 6"

FLOOR PLAN

0' - 0"

TOP PLATE

9' - 0"

APPROX. GROUND

-2' - 6"

FLOOR PLAN

0' - 0"

TOP PLATE

9' - 0"

APPROX. GROUND

-2' - 6"

C

AR

VE

R

PA

RK

C O

M M

UN

ITY

C

EN

TE

R

W eb b St

, C an to nm en t, FL

N ew

M od ul ar

: 8 5 0 - 7 1 2 - 6 5 7 1 :

scott@deandesignbuild.com b u i l d d e s i g n d e a n i n c 2301 tobie dean road Cantonment, FL 32533

A201

EX

TE

RI

O

R

EL

EV

A

TIO

N

S

NORTH ELEVATION1

SOUTH ELEVATION2

EAST ELEVATION1

WEST ELEVATION1

12/1/2024

A CB

DN

DN

C

AR

VE

R

PA

RK

C O

M M

UN

ITY

C

EN

TE

R

W eb b St

, C an to nm en t, FL

N ew

M od ul ar

: 8 5 0 - 7 1 2 - 6 5 7 1 :

scott@deandesignbuild.com b u i l d d e s i g n d e a n i n c 2301 tobie dean road Cantonment, FL 32533

E101

12/1/2024

SC

HE

M A

TIC

P

O W

ER

/D

A

TA

POWER PLAN1

RFP

dean

NON-FUSIBLE DISCONNECT SWITCH RATED FOR 240VAC IN NEMA 1

EN-CLOSURE (UON). SIZE AS REQUIRED BY EQUIPT. NAMEPLATE RATING.

400amp MAIN DISTRIBUTION PANEL

20 AMP, 125V, GROUNDED TYPE DUPLEX RECEPTACLE MOUNTED 18" A.F.F.,

UNLESS NOTED

20 AMP, 125V, GROUNDED DUPLEX RECEPTACLE, W/TYPE A & C USB,

MOUNTED 18" A.F.F., UNLESS NOTED

GROUND FAULT INTERUPTING 20 AMP, 125V, GROUNDED DUPLEX

RECEPTACLE MOUNTED 48" A.F.F. AND READILY ACCESSIBLE.

DATA OUTLET - 4 1/2" SQ. X 2 1/8" DEEP BOX WITH 1" SMURF PIPE STUBBED FOR

ACCESS BY COMMUNICATIONS CONTRACTOR, MOUNTED 18" A.F.F. UNLESS NOTED

OTHERWISE

JUNCTION BOX FOR EQUIPMENT AS NOTED, SIZE AS REQUIRED BY N.E.C. AND

MOUNTED AS REQUIRED BY EQUIPMENT BEING SERVED.J

NOTE: ALL SYMBOLS MAY NOT BE USED

DEDICATED 20 AMP, 125V, GROUNDED DUPLEX RECEPTACLE, MOUNTED 18"

A.F.F., UNLESS NOTED

A CB

DN

DN

J

C

AR

VE

R

PA

RK

C O

M M

UN

ITY

C

EN

TE

R

W eb b St

, C an to nm en t, FL

N ew

M od ul ar

: 8 5 0 - 7 1 2 - 6 5 7 1 :

scott@deandesignbuild.com b u i l d d e s i g n d e a n i n c 2301 tobie dean road Cantonment, FL 32533

E102

12/1/2024

SC

HE

M A

TIC

L

IG

HT

IN

G

LIGHTING PLAN1

RFP

dean

GENERAL ELECTRICAL NOTES:

1. ALL WIRE SHALL BE COPPER CONDUCTOR AND INSTALLED IN MC CABLE OR CONDUIT AS REQUIRED BY

LOCAL CODE.

2. ALL WIRE SHALL HAVE THWN INSULATION MINIMUM UNLESS NOTED OTHERWISE.

3. ALL WORK AND WIRING SHALL MEET OR EXCEED THE CURRENT ADOPTED VERSION OF THE NATIONAL

ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.

4. THE ELECTRICAL CONTRACTOR SHALL VISIT JOB SITE AND BECOME FAMILIAR WITH EXTENT OF WORK

REQUIRED TO COMPLETE JOB PRIOR TO BIDDING.

5. ALL WORK THAT INVOLVES MECHANICAL EQUIPMENT (INCLUDING POWER REQUIREMENTS AND LOCATION)

SHALL BE CONFIRMED AND COORDINATED BETWEEN THE MECHANICAL AND ELECTRICAL CONTRACTORS

PRIOR TO ROUGH-IN AND PURCHASE OF EQUIPMENT.

6. CIRCUIT ROUTING IS THE OPTION OF THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED.

CONTRACTOR SHALL COORDINATE EXACT ROUTING IN FIELD AND SHALL MATCH THE CIRCUITS TO THE PANEL SCHEDULE LABELING. MAXIMUM LOAD PER CIRCUIT SHALL NOT EXCEED THE LOAD AS LABELED ON

THE PANEL SCHEDULE.

7. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF NEW ELECTRICAL WORK WITH ARCHITECTURAL, CIVIL, MECHANICAL AND STRUCTURAL SYSTEMS PRIOR TO START OF WORK.

8. EXIT/EMERGENCY LIGHTING SHALL BE TIED AHEAD OF LOCAL SWITCHING ON THE LIGHTING CIRCUIT FOR

THE AREA THEY SERVE.

9. COORDINATE ALL POWER REQUIREMENTS, LOCATIONS AND MOUNTING HEIGHTS WITH SPECIALTY EQUIPMENT

SUPPLIER/INSTALLER.

10. PER NEC - RESTROOMS, KITCHENS/BREAKROOMS, ROOFTOPS & OUTSIDE RECEPTICALS SHALL HAVE GFCI PROTECTION

AND THE CIRCUIT INTERUPTOR SHALL BE PLACED IN A READILY ACCESSIBLE LOCATION.

20 AMP, 125 VOLT, SINGLE POLE TOGGLE SWITCH, MOUNT 48" AFF

EXHAUST FAN, INSTALLED BY HVAC CONTRACTOR WIRED BY ELECTRICAL

CONTRACTOR

COMBINATION EMERGENCY EXIT & LIGHT FIXTURE WITH BATTERY BACKUP

20 AMP, 125 VOLT, SINGLE POLE OCCUPANT SENSING SWITCH, MOUNT 48" AFF

EMERGENCY LIGHT FIXTURE WITH BATTERY BACKUP

360° OCCUPANT SENSOR

6" RECESSED LED DOWN LIGHT - (HALO HC620D010REM7-HM60525835-61MDC OR EQUAL)

COORDINATE WITH FURNITURE AS SHOWN

48" LED SURFACE MOUNT (FINISH TO MATCH IMAGE DOCS) - 80 CRI, 3500K, 4000 LUMENS

(LITHONIA: CLX SERIES OR APPROVED EQUAL)

PANEL / CIRCUIT NUMBER

INDICATES FIXTURES ON SAME CIRCUIT WITH SEPARATE SWITCHING

2x2 TROFFER - 27w LED, 4563 LUMENS, 40K CCT (LITHONIA: STAKS 2X2 ALO3 SWW7 OR

EQUAL)

ILLUMINATED EXIT SIGN WITH DIRECTION INDICATOR

NOTE: ALL SYMBOLS MAY NOT BE USED

ABOVE FINISHED FLOORAFF

UNO

WH

AHU

HPU

GND

TYP

HEAT PUMP UNIT

TYPICAL

GROUND

AIR HANDLING UNIT

UNLESS NOTED OTHERWISE

ELECTRIC WATER HEATER

(ABREVIATIONS)

EM EMERGENCY BATTERY BACKUP

WP WATER PROOF

USB UNIVERSAL SERIAL BUSS