CAMP Plumb Roof Drawing.pdf
PDF 396 KB Posted
- Attached to
- FCC Terre Haute FPC HVAC PLUM ROOF REPAIR
- Solicitation number
- 15B41825PR000085
About this file
This is a technical drawing set for a roof replacement project at FCC Terre Haute, a federal facility operated by the United States Department of Justice Federal Bureau of Prisons located at 4200 Bureau Road in Terre Haute, Indiana 47802. The project, identified as M.W.O Number 24Z4AT8 and Project Number 68651, involves the complete demolition of the existing 7:12 sloped composite shingle roof down to the deck and installation of a new standing seam metal roof assembly. The new roofing system includes underlay, water and ice shield, drip edge, flashing, counter flashing, and snow cleats where applicable. Additionally, new metal guttering and downspouts will be installed throughout the facility. The roof dimensions span approximately 137'-10" in length with varying widths of 8'-6", 11'-11", and 20'-5" across different sections, with a 7-12 roof pitch. Existing roof penetrations will be retained and receive new flashing and sealant as needed.
The drawing set establishes general contractor requirements including field verification of all dimensions, materials, and utility locations before construction begins, adherence to applicable codes including IBC, UBC, NFPA, ADA, and OSHA standards, verification of roof penetration locations and types prior to work commencement, and provision of all necessary blocking, backing, framing, hangers, and support for installed equipment. The drawings include elevations and sections at 1/16" = 1'-0" scale for the east, west, north, and south sides of the structure. The technical approval set was dated September 25, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Market Research Questionnaire CAMP ROOF.pdf | ||
| SOW CAMP HVAC PLUMB COMM SHOPS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8' -6
'-1 1"
'-5
137'-10"
13'-8" 42'-0"
C2C1
C4
7" 12"
8' -6
'-1 1"
'-5
137'-10"
13'-8"42'-0"
C2C1
C4
7" 12"
8' -6
'-1 1"
2' -1
1"
5' -1
0"
C4
C1
C2
7" 12"
8' -6
'-1 1"
'-5
137'-2"9'-4"
C1 C2
C3 C3
C4
C4
DRAWING TITLE
SHEET NUMBER
of
REVISIONS
U n it ed
S ta te s
D ep a rt m en t o f
J u st ic e F ed er a l
B u re a u o f
P ri so n s F
C C
T er re H a u te B u re a u
R o a d T er re
H a u te In d ia n a
PROJECT NUMBER
DRAWN BY
PROJECT NAME
M.W.O NUMBER
24Z4AT8
REPLACE ROOF FPC
PROJECT REVIEW SET 9.24.24
68651
NIC LAMPHEAR
TECHNICAL APPROVAL SET 9.25.24
1.) DIMENSIONS, MATERIALS, AND LOCATIONS ARE
SHOWN AS ACCURATELY AS POSSIBLE. HOWEVER ALL
SHOULD BE FIELD VERIFIED BY THE CONTRACTOR
BEFORE ANY FORM OF CONSTRUCTION OR DEMOLITION
BEGINS.
2.) DIMENSIONS SHOWN ON FLOOR PLANS, AND DETAILS
ARE DRAWN TO FACE OF STRUCTURE UNLESS
OTHERWISE SHOWN OR NOTED.
3.) ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER
SCALE. UNDER NO CIRCUMSTANCE SHALL THE
CONTRACTOR SCALE THE DRAWINGS FOR DIMENSION.
4.) ALL DATA, EXISTING STRUCTURES, AND UTILITIES ABOVE
OR BELOW GROUND WITHIN THE LIMITS OF THIS
PROJECT SHALL BE CHECKED BY THE CONTRACTOR
BEFORE ANY FORM OF CONSTRUCTION OR DEMOLITION
BEGINS. IN CASES OF CONFLICT THE CONTRACT
REPRESENTATIVE AND ARCHITECT SHALL BE
NOTIFIED IMMEDIATELY, IN ORDER THAT CLARIFICATION
OR CORRECTION MAY BE MADE.
5.) UNLESS OTHERWISE SHOWN OR NOTED, THE
CONTRACTOR SHALL USE CONSTRUCTION DETAILS AND
PRACTICES COMMON TO THE STANDARDS OF THE
TRADE.
6.) THE CONTRACTOR SHALL PROVIDE ALL THE NECESSARY
BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER
SUPPORT FOR ALL ITEMS REQUIRING THE SAME.
7.) ALL WORK SHALL CONFORM TO THE APPLICABLE CODES
AND AUTHORITIES INCLUDING, BUT NOT LIMITED TO IBC,
UBC, NFPA, ADA, AND OSHA AND SHALL BE OF THE BEST
PRACTICE OF EACH TRADE.
8.) THE CONTRACTOR SHALL VERIFY AND MAINTAIN ALL THE
REQUIRED CLEARANCES AROUND INSTALLED
EQUIPMENT.
9.) THE CONTRACTOR SHALL VERIFY ALL ROOF
PENETRATION LOCATIONS, AMOUNTS, AND TYPES
BEFORE ANY FORM OF CONSTRUCTION OR DEMOLITION
BEGINS.
GENERAL NOTES
EXISTING 7:12 SLOPED COMPOSITE SHINGLE ROOF TO BE
DEMOLISHED TO DECK, TYP.
NEW STANDING SEAM METAL ROOF ASSEMBLY. NEW
ROOFING SYSTEM TO INCLUDE NEW UNDERLAY, WATER &
ICE SHIELD, DRIP EDGE, FLASHING, COUNTER FLASHING,
AND SNOW CLEATS WHERE APPLICABLE, TYP.
EXISTING ROOF PENETRATION TO REMAIN. PENETRATION
TO RECEIVE FLASHING AND SEALANT WHERE APPLICABLE,
TYP.
NEW METAL GUTTERING AND DOWNSPOUTS TO BE
INSTALLED, TYP.
C2
CONSTRUCTION NOTES
C1
C4
C3
A2 02
ELEVATIONS + SECTIONS
SCALE: 1/16" = 1'-0"
A2
SOUTH ELEVATION
SCALE: 1/16" = 1'-0"
A2
NORTH ELEVATION
SCALE: 1/16" = 1'-0"
A2
EAST ELEVATION
SCALE: 1/16" = 1'-0"
A2
EAST ELEVATION