Camp Grafton Steam Kettle Product Description.pdf

PDF 583 KB Posted

Attached to
Camp Grafton Training Center (DFAC) Brand Name or Equal - KETTLE CABINET ASSEMBLY, GAS
Solicitation number
W901UZ26Q6566
Issued by

About this file

This document is a product specification sheet for a Southbend (Middleby) Model GMT-10S-10 Direct Steam Kettle on Gas Boiler Base procured for Camp Grafton Training Center. The equipment consists of two 10-gallon (38-liter) tilting kettles mounted on a 42-inch gas boiler base with a 2/3 steam jacket, hemispherical kettle bottom for superior heat circulation, and 316 stainless steel interior for high-acid content products. Standard features include electronic ignition, automatic boiler blowdown, CSD-1 boiler controls, water treatment system with split water line, and safety relief valves. The unit operates on natural gas or LP gas at 250,000 BTU/hour (standard) or 300,000 BTU/hour (optional) and requires 115 VAC, 1-phase, 50/60 Hz electrical supply.

The equipment package includes domestic shipping within North America, one-year limited parts and labor warranty, STOK steam take-off kit, two C-10 lift-off covers, two SSB-10 stainless steel baskets, two GM-10 etched interior markings (gallons or liters), two TKS-10 kettle strainers, and a TruH2O multi-stage water treatment system (Model 71528211). Service connections require 1/2-inch electrical conduit, 2-inch drain piped to open floor drain, 3/8-inch tubing for condensate/boiler/faucet water at 25-50 PSI, 3/4-inch gas supply line, and optional 3/4-inch steam take-off connection. The unit weighs 820 pounds and requires minimum clearances of 3 inches on sides and 6 inches at back. Water quality must meet specific standards (total dissolved solids less than 60 PPM, chlorine less than 1.5 PPM, pH 6.8-7.3), and failure or malfunction due to poor water quality is not covered under warranty.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item Qty Description

1 1 ea KETTLE CABINET ASSEMBLY, GAS Southbend (Middleby) Model No. GMT‐10S‐10 Kettle/Cabinet Assembly, gas, (2) 10 gallon tilting kettles, 2/3 jacket, 42" cabinet base, electronic ignition, automatic boiler blow down, double pantry fill faucet, 3" deep stainless steel sink, CSD‐1 package, water treatment system, split water line, safety relief valve, 316 stainless steel liner, 304 stainless steel exterior finish, 6" stainless steel legs & adjustable flanged feet, NSF, CSA Star, CSA Flame

1 ea NOTE: Failure or malfunction of this appliance due to poor water quality is not covered under warranty. Contact Crown for water quality solutions

1 ea Domestic Shipping, inside of North America 1 ea Standard (1) year limited parts & labor warranty 1 ea Natural Gas 1 ea 115v/50/60/1‐ph, standard 1 ea Add for 300,000 BTU in lieu of std. 250,000 BTU 1 ea STOK Steam take‐off kit for steam kettles 2 ea C‐10 Cover, lift off, for 10 gallon kettle 2 ea SSB‐10 Single perforated stainless steel basket for 10, 12 or 20 gal 2 ea GM‐10 Permanent etched interior markings, for 10 gallon kettle

(specify gallon or liter markings) 2 ea TKS‐10 Kettle strainer, 10 gallon, pour lip 1 ea 71528211 TruH2O Water Treatment System (multi‐stage pack), neutralizes scale, up to 99% chlorine reduction, 5 micron filtration, quick disconnect, easy cartridge change out

Terms of Sale:

Camp Gra on Ke les

Product Description Steam Kettle

Camp Grafton Training Center

Approval Notes: ________________________________

G M

T-10S-10

Job: Item#

STANDARD CONSTRUCTION SPECIFICATIONS

Shall be a Southbend Steam model GMT-10S-10, consisting of two direct connected steam, tilting kettles, two 10 gallon (38 liters).

A double wall kettle interior shall form a steam jacket around the lower 2/3 of the kettle.

The bottom of the kettle shall be of hemispherical design for superior heat circulation.

The kettle interior shall be of 316 stainless steel for high acid content products.

The stainless steel mounting legs shall have the steam supply and condensate within the legs and the right leg fitted with a steam control valve for the kettle.

Each kettle shall be fitted with a tilt handle and heat resistant knob, allowing the kettles to be tilted forward past 90° for complete emptying.

The kettles shall be mounted on a cabinet base with full perimeter angle frame, reinforced counter, hot and cold water faucet with controls valves 3” (76 mm) deep sinks with drain, grates and splash guard, hinged doors with magnetic catches, removable side panels and 6” (152 mm) stainless steel legs fitted with 4 adjustable flanged feet for securing to the floor, all #4 stainless steel exterior with aluminized steel back.

Boiler controls shall include automatic water level control, automatic blowdown, pressure gauge, water gauge glass, operating pressure control, safety high-limit pressure control, safety relief valve, split water line, electronic ignition, CSD-1 boiler controls, On/Off switch with indicator light, and electronic ignition.

Steam manifolds concealed within cabinet are fitted with a safety relief valve and steam trap for each kettle. Water treatment system comes standard.

*SEE REVERSE SIDE OF SPEC SHEET FOR WATER TREATMENT

SYSTEM STATEMENTS*

Floor Protective Panel for 36" Gas Boiler Based Cabinets and Up (aluminum panel, painted on top with special anti-reflective black paint)

(8976-1-SB)

Floor Protective Panel 24" Gas Boiler Based Cabinets (aluminum panel, painted on top with special anti-reflective black paint) (8978-1-SB)

OPTIONS & ACCESSORIES

300,000 BTU boiler
220-240 VAC operation

(specify voltage) (GBVS-1)

Stainless steel rear panel (SSB-)
Stainless steel frame (SSF-)
Etched Gallon (GM)
Liter markings (LM)
Pour lip strainer (TKS)
One piece stainless steel lift off cover (C-)
Lift out stainless steel basket (SSB-)
Correctional package
Spray and rinse assembly (SP-RSH or DP-RSH)
Steam take-off kit (STOK)
Water in “Y” strainer (condenser feed)

Nickel plated boiler shell (NPBS)

Direct Steam Kettle on Gas Boiler Base

GMT-10S-10

OPERATION SHALL BE BY:

Gas operated 15 psi (103 kPa) steam boiler for operation on 115 VAC, 1 phase, 50/60 Hz rated at 250,000 BTU.

Natural Gas
LP Gas

Standard Features

• Water Treatment System

• Split water line

• Electronic ignition

• CSD-1 Boiler controls

• Automatic boiler blowdown

GMT‐10S‐10

Models:

G M

T-10S-10

GMT-10S-10

INTENDED FOR COMMERCIAL USE ONLY.

NOT FOR HOUSEHOLD USE.

GAS SUPPLY AND SPECIFICATIONS

BTU/Hour kW/Hour Minimum Inlet Pressure:

Natural Propane

250,000 73.3 4” W.C.

Static to unit

11” W.C.

Static to unit300,000 87.9

SERVICE CONNECTIONS

NOTE: SPLASH GUARD NOT SHOWN IN FRONT VIEW. IN [MM]

Model Description Capacity (Per Kettle) Shipping

Weight Min. Clearance Gallon Liter

GMT-10S-10

(2) 10 gallon kettle on 42” gas boiler base

10 38 820 lbs.

[372 kg.]

SIDES 3 [76 mm] BACK 6 [152 mm]

– ELECTRICAL CONNECTION: 1/2” (13 mm) O.D. conduit connection to controls. 120 VAC-1PH with grounding wire required unless otherwise noted.

– DRAIN: 2” (51 mm) IPS piped to open floor drain. No solid connection.

– CONDENSATE COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa).

– BOILER COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa). [TREATED WATER]

– FAUCET COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61 compliant.

– FAUCET HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61 compliant.

– GAS CONNECTION: 3/4” (19 mm) IPS supply line required.

Natural Gas: Min. 4” (102 mm) Water Column.

propane: Min. 11” (279 mm) Water Column.

– STEAM TAKE-OFF CONNECTION: 3/4” (19 mm) IPS optional to operate adjacent equipment.

SD – SINK DRAIN: 1-1/8” O.D. tubing

If installing on any floor with an epoxy coating or other combustible floor surface (i.e., a surface other than quarry tile, cement or natural stone), contact the factory for installation options as damage due to improper installation is not covered under warranty.

Terry System Cartridge Changes / Installation – “2-3 gallons of water MUST be purged at each cartridge change or new installation prior to water supply being fed to the steamer. Failure to do so can result in component damage within the steamer which is not covered under warranty.

For additional guidance on proper installation, refer to install documentation provided with each Terry System and Replacement Cartridge Set.”

DISCLAIMER

WATER QUALITY STATEMENT

Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.

Total dissolved solids.......................Less than 60 PPMChlorine .............................Less than 1.5 PPM
Total alkalinity ......................................... Less than 20 PPMpH Factor ..........................6.8 - 7.3

Silica........................................................ Less than 13 PPM

Water which does not meet these standards should be treated with the installation of Middleby’s Water Treatment System. Call 919-762-1000 if you have questions concerning your water meeting these parameters.

*Failure or malfunction of this appliance due to poor water quality is not covered under warranty.

Reference www.crownsteamgroup.com for complete warranty details and instructions.

GMT10S‐10

File details come from the government source that posted it. Updated .