This is a design document for a roof replacement project at the National Peanut Research Laboratory in Dawson, Georgia. The project is a 100% submittal prepared under USDA Agricultural Research Service Contract #12405B21D0003, Order #1232SA26F0109. The design was prepared by Johnson M Adams Architects/Engineers (P.O. Box 513, Greenwood, Mississippi, 662-455-4943) and reviewed by USDA Facilities Engineering Branch (5106 Sunnyside Avenue, Beltsville, MD 20705-5100), dated July 2, 2026.
The project encompasses complete roof replacement for Building 1, including demolition of the existing roof system and installation of a new modified bitumen roof system with specific performance requirements. Key design elements include: mechanically attached cover board over existing Tectum deck; fully adhered tapered polyisocyanurate rigid insulation (minimum R-25) maintaining 1/4" per 12" slope; fully adhered cover board; and 3-ply modified bitumen granule surface cap sheet with white granules. The design maintains minimum overall R-value of 25 for the completed roof assembly. Project scope includes management of existing roof penetrations (vents, drains, equipment curbs, pitch pots, and chimney), provision of new insulated curbs for equipment, retrofit roof drain inserts, and a manufacturer-engineered fall protection system. A bid alternate (Option #1) includes exterior stair construction with concrete foundation slab, steel bar grating treads, and welded handrails. The contractor must provide a line-item sum for replacement of 10% of the existing 3-inch Tectum roof deck. Design references include NRCA standards, manufacturer shop drawings, and structural reference drawing RF-001 showing joist bearing elevations and tapered insulation layout requirements.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION:
NATIONAL PEANUT
RESEARCH LABORATORY
1011 FORRESTER DR,
S.E. DAWSON, GA. 39842
NO SCALEVICINITY MAP
N
LOCATION MAP NO SCALE
N
PROJECT
LOCATION
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
COVER SHEET
G100 1 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
SHEET
NO.
DRAWING
NO. TITLE
GENERAL
G100 1 OF 7 COVER SHEET
ARCHITECTURAL
D100 2 OF 7 ROOF PLAN: DEMOLITION
A100 3 OF 7 BASE BID: ROOF PLAN
A110 4 OF 7 BASE BID: DETAILS
A200 5 OF 7 BID OPTION #1: FLOOR PLANS
A210 6 OF 7 BID OPTION #1: STAIR SECTION / DETAILS
RF001 7 OF 7 STRUCTURAL REFERENCE DRAWING
DRAWING INDEX
USDA
DAWSON, GEORGIA
AGRICULTURAL RESEARCH SERVICE
U.S. DEPARTMENT OF AGRICULTURE
BUILDING 1 ROOF REPLACEMENT DESIGN
100% SUBMITTAL
CONTRACT #: 12405B21D0003
ORDER #: 1232SA26F0109
4'- 0"
1'-6"
2" VTR.
2" SATELLITE MOUNT
1'-10"
1'-
3" VTR
3'-4"
3'- 4"
BRICK CHIMNEY
3" VTR
4" VTR
3'-8"
3'- 8"
2" VTR
2'-0"
2'- 0"
4" VTR
3" VTR 2" VTR
2" VTR4" VTR
4" VTR
3" VTR
1'-8"
6'- 2"
1'-8"
6'- 2"
1'-8"
6'- 2"
1'-8"
6'- 2"
4" VTR
3" VTR
6'- 2"
2" VTR
1'-8"
2'-8"
2'- 8"
P.P.
P.P.
P.P.
P.P.
6'- 2"
1'-8"
3" VTR
6'- 2"
P.P.
P.P.
P.P.
6'- 2"
1'-8"
1'-8"
2" VTR
P.P.
1'- 8"
6'-2"
2" VTR
4" VTR
2'-6"
2'- 6"
RD RD RD RD RD RD
RD
RD RD
RD RD RD
194'-0"
'-0
1/ 8"
106'-0 1/2"
8'-
4"
'-0
29'-11 1/2"
58'-0"
'-3
7/ 8"
LEGEND
EXISTING VENT THROUGH ROOF. SEE PLAN FOR SIZE.
DEMOLISH FLASHING COMPLETE PROTECT VENT DURING
DEMOLITION.3" VTR
RD
P.P.
EXISTING CURB MOUNTED EQUIPMENT TO REMAIN. SEE
PLAN FOR SIZE. MANIPULATE EXISTING EQUIPMENT AS
REQUIRED TO DEMOLISH EXISTING ROOF CURB COMPLETE.
SEE SHEET A100 FOR NEW WORK.
EXISTING ROOF DRAIN. DEMOLISH ROOF STRAINER AND
RETENTION RING COMPLETE. PROTECT DRAIN PIPING
DURING DEMOLITION.
EXISTING PITCH POT. MANIPULATE EXISTING EQUIPMENT AS
REQUIRED TO DEMOLISH PITCH POT COMPLETE. SEE
SHEET A100 FOR NEW WORK.
KEYED NOTE
1. DEMOLISH EXISTING ROOF SYSTEM AND FLASHING COMPLETE BACK TO
EXISTING ROOF DECK. PROTECT EXISTING ROOF DECK DURING DEMOLITION.
SLOPE SLOPE
SL
OP
E
SLOPE SL
OP
E
SL
OP
E
P.P.
GENERAL NOTE
1. ALL EXISTING EQUIPMENT TO REMAIN UNLESS NOTED OTHERWISE. NOTIFY
FACILITY PERSONNEL 72 HOURS PRIOR TO DISCONNECTING EQUIPMENT.
EXISTING CURB MOUNTED EQUIPMENT AND ROOF CURB TO
BE DEMOLISHED COMPLETE. SEE PLAN FOR SIZE. SEE
SHEET A100 FOR NEW WORK.
NO WORK THIS AREA
EXISTING ROOF
ACCESS LADDER TO
REMAIN
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
ROOF PLAN: DEMOLITION
D100 2 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
ROOF PLAN: DEMOLITION
1/8" = 1'-0"
D100
4'- 0"
1'-6"
2" VTR.
2" SATELLITE MOUNT
1'-10"
1'-
3" VTR
3'-4"
3'- 4"
BRICK CHIMNEY SEE
FLASHING DETAIL 5/A110
3" VTR
4" VTR
3'-8"
3'- 8"
2" VTR
2'-0"
2'- 0"
4" VTR
3" VTR 2" VTR
2" VTR
4" VTR
4" VTR
3" VTR
1'-8"
6'- 2"
1'-8"
6'- 2"
1'-8"
6'- 2"
1'-8"
6'- 2"
4" VTR
3" VTR
6'- 2"
2" VTR
1'-8"
2'-8"
2'- 8"
P.P.
P.P.
P.P.
P.P.
6'- 2"
1'-8"
3" VTR
6'- 2"
P.P.
P.P.
P.P.
6'- 2"
1'-8"
1'-8"
2" VTR
P.P.
1'- 8"
6'-2"
2" VTR
4" VTR
2'-6"
2'- 6"
RD RD RD RD RD RD
RD
RD RD
RD
RD RD
194'-0"
'-0
1/ 8"
106'-0 1/2"
8'-
4"
'-0
29'-11 1/2"
58'-0"
'-3
7/ 8"
LEGEND
PLUMBING VENT. SEE PLAN FOR SIZE. 1/A110.
3" VTR
RD
P.P.
CURB MOUNTED EQUIPMENT. SEE PLAN FOR SIZE. SEE
DETAIL 3/A110. EXISTING EQUIPMENT TO REMAIN. PROVIDE
NEW CURB TO ACCOMMODATE NEW ROOF SYSTEM. NOTIFY
FACILITY PERSONNEL 72 HOURS PRIOR TO DISCONNECTING
EQUIPMENT.
ROOF DRAIN. PROVIDE ROOF RETROFIT ROOF DRAIN
INSERTS WITH ALUMINUM DOME STRAINER, FLAT SUMP
ROOF DRAIN, AND VANDAL PROOF SCREWS FOR DOME.
BASIS OF DESIGN: ZURN RD2150. SEE DETAIL 4/A110
PITCH POT PENETRATION. SEE DETAIL 2/A110. SEE
MECHANICAL / ELECTRICAL FOR ADDITIONAL WORK.
KEYED NOTE
1. PROVIDE NEW MODIFIED BITUMEN ROOF SYSTEM AS FOLLOWS:
1.1. PROVIDE MECHANICALLY ATTACHED COVER BOARD OVER EXISTING
TECTUM DECK.
1.2. PROVIDE FULLY ADHERED TAPERED INSULATION SYSTEM. MAINTAIN A
MINIMUM 1/4" PER 12" SLOPE.
1.3. PROVIDED FULLY ADHERED COVER BOARD.
1.4. PROVIDE 3 PLY, MODIFIED ROOF.
1.5. ASSUMING THE EXISTING 3" TECTUM ROOF DECK HAS AN R-VALUE OF
5.25. THE ROOFING INSULATION SYSTEM SHALL HAVE A MINIMUM
OVERALL R-VALUE OF 20 TO PROVIDE A MINIMUM OVERALL R-VALUE OF
25 FOR THE ROOF.
SEE REFERENCE DRAWING RF-001 FROM ORIGINAL CONSTRUCTION DOCUMENTS
FOR STRUCTURAL ROOF DECK SLOPES
SLOPE SLOPE
NO WORK THIS AREA
FALL PROTECTION SYSTEM NOTE: ROOF DECK MOUNTED
THE EXISTING ROOF DECK IS 3” THICK TECTUM WITH AN ESTIMATED AVERAGE ULTIMATE PULL-OUT
AS LISTED BELOW.
EMBEDMENT INTO TECTUM AVERAGE ULTIMATE PULL-OUT:
1-1/2 INCHES 280 LB
2 INCHES 440 LB
2-1/2 INCHES 595 LB
PROVIDE MANUFACTURER-ENGINEERED AND CERTIFIED FALL PROTECTION SYSTEM, INCLUDING
POSTS, ANCHORS, FASTENERS, BASE PLATES, HORIZONTAL LIFELINE, END ANCHORS,
INTERMEDIATE SUPPORTS, AND CONNECTION TO THE ROOF STRUCTURE. ATTACHMENT TO
EXISTING 3-INCH TECTUM DECK SHALL BE VERIFIED BY FIELD PULL-OUT TESTING AND SHALL NOT RELY SOLELY ON TABULATED AVERAGE FASTENER PULL-OUT VALUES. SYSTEM SHALL MEET OSHA FALL-ARREST ANCHORAGE REQUIREMENTS OF 5,000 LB PER ATTACHED USER OR BE DESIGNED AS
A COMPLETE FALL-ARREST SYSTEM WITH A MINIMUM SAFETY FACTOR OF 2 BY A QUALIFIED
PERSON.
LINE OF WALL BELOW
LINE OF WALL BELOW
EXISTING ROOF
ACCESS LADDER TO
REMAIN
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
5 1/4" STRUCTURAL
ROOF SLOPE
WATER FLOW INDICATOR
CRICKET
PROVIDE MINIMUM 3' WALK
PAD AROUND EQUIPMENT
SEE DETAIL 7/A110
19'-2 1/2"
EXISTING CURB OPENING TO BE CAPPED. SEE PLAN FOR
SIZE AND DETAIL 6/A110. PROVIDE NEW CURB TO
ACCOMMODATE NEW ROOF SYSTEM.
P.P.
ROOF DECK NOTE
CONTRACTOR SHALL PROVIDE A LINE ITEM SUM IN
THE BID PACKAGE FOR THE REPLACEMENT OF 10%
OF THE EXISTING 3" TECTUM ROOF DECK.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
BASE BID: ROOF PLAN
A100 3 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
BASE BID: ROOF PLAN
1/8" = 1'-0"
A100
6" MIN. 3" MIN. 3" MIN.
EXISTING VENT THROUGH ROOF
COPPER PIPE FLASHING ROLL INTO PIPE MIN. 1"
FULLY ADHERED BASE
SHEET
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
FULLY ADHERED MODIFIED BITUMEN
GRANULE (WHITE) SURFACE CAP SHEET
FULLY ADHERED INTER-PLY SHEET
6" MIN FLANGE, SET IN FLASHING
CEMENT OVER FIELD PLIES (PRIME
FLANGE BEFORE STRIPPING)
SEALANT CONT.
SCALE:
VENT THROUGH ROOF DETAIL
3" = 1'-0"
A110
4" MIN. 3" MIN. 3" MIN.
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
FULLY ADHERED MODIFIED BITUMEN
GRANULE (WHITE) SURFACE CAP SHEET
FULLY ADHERED INTER-PLY SHEET
4" MIN FLANGE, SET IN FLASHING
CEMENT OVER FIELD PLIES (PRIME
FLANGE BEFORE STRIPPING)
SEALANT CONT.
SHEET METAL PITCH PAN SOLDIERED
OR WELDED WATER TIGHT
NON SHRINK GROUT
POURABLE SEALANT MIN. 2"
ABOVE NON SHRINK GROUT
PRIME PENETRATION ABOVE THE HEIGHT
OF FINISHED POURABLE SEALER
SCALE:
PITCH POT DETAIL
3" = 1'-0"
A110
EXISTING PENETARTION THROUGH ROOF
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
2 X 6 TREATED BLOCKING AS SPECIFIED
FULLY ADHERED
TAPERED POLY ISO
RIGID INSULATION R-25
MIN.
2 X 6 TREATED BLOCKING AS SPECIFIED
SCALE:
ROOF DRAIN RETROFIT DETAIL
3" = 1'-0"
A110
FULLY ADHERED INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
3" MIN. 3" MIN.
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
SHEET METAL COUNTER FLASHING
ROOF TOP EQUIPMENT
PRE-MANUFACTURED
INSULATED ROOF CURB
SCALE:
CURB DETAIL
3" = 1'-0"
A110
CANT STRIP AS
SPECIFIED
2 X 6 TREATED BLOCKING AS SPECIFIED
12" MIN.
MECHANICALLY
FASTENED 1/2"
COVER BOARD
2 X 6 TREATED BLOCKING AS SPECIFIED
FULLY ADHERED BASE
SHEET
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
FULLY ADHERED
TAPERED POLY ISO
RIGID INSULATION
R-25 MIN.
MECHANICALLY
FASTENED 1/2"
COVER BOARD
FULLY ADHERED BASE
SHEET
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
FULLY ADHERED
TAPERED POLY ISO
RIGID INSULATION
R-25 MIN.
MECHANICALLY
FASTENED 1/2"
COVER BOARD
CANT STRIP AS
SPECIFIED
BLOCKING AS
REQUIRED
CONT.
EXISTING
EXTERIOR WALL
2 X 4 TREATED
BLOCKING AS
SPECIFIED
NEW SHEET METAL COPING
NEW COPING ANCHOR CLIP
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET. CONTINUE
SHEET UP AND OVER PARAPET.
FULLY ADHERED BASE
SHEET
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
FULLY ADHERED
TAPERED POLY ISO
RIGID INSULATION R-25
MIN.
MECHANICALLY
FASTENED 1/2"
COVER BOARD
FULLY ADHERED
INTER-PLY SHEET
ALUMINUM DOME STRAINER
STAINLESS STEEL STUDS,
WASHERS, AND NUTS
CLAMPING RING.
30" x 30" MIN. COPPER FLASHING SET ON BASE
PLY SHEET IN BED OF FLASHING CEMENT. PRIME
SURFACE BEFORE STRIPPING.
ALUMINUM FLANGE
ANCHORED TO DECK
EXISTING ROOF DRAIN BOWL
EXISTING ROOF DRAIN PIPE
RUBBER SEAL
16" LONG ALUMINUM DRAIN TUBE INSERT
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
3" MIN. 3" MIN.
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
SHEET METAL COUNTER FLASHING
PRE-MANUFACTURED
INSULATED ROOF CURB
SCALE:
CURB CAP DETAIL
3" = 1'-0"
A110
CANT STRIP AS
SPECIFIED
2 X 6 TREATED BLOCKING AS SPECIFIED
FULLY ADHERED BASE
SHEET
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
FULLY ADHERED
TAPERED POLY ISO
RIGID INSULATION
R-25 MIN.
MECHANICALLY
FASTENED 1/2"
COVER BOARD
PROVIDE 18 GA. S.S. x INSULATED CAP INSULATED
WITH MINIMUM 1" POLY ISO RIGID INSULATION
ADHESIVE APPLIED TO UNDERSIDE OF CAP.
SEE PLAN FOR SIZE.1"
12"
4"
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
FULLY ADHERED BASE
SHEET
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
FULLY ADHERED TAPERED
POLY ISO RIGID INSULATION
R-25 MIN.
MECHANICALLY FASTENED
1/2" COVER BOARD
FULLY ADHERED MODIFIED BITUMEN
GRANULE (WHITE) WALK PAD AS
SPECIFIED.
SCALE:
WALK PAD DETAIL
3" = 1'-0"
A110
FULLY ADHERED INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
3" MIN. 3" MIN.
FULLY ADHERED
INTER-PLY SHEET
FULLY ADHERED MODIFIED
BITUMEN GRANULE (WHITE)
SURFACE CAP SHEET
SHEET METAL FLASHING WITH CONT. CLEAT
2 X 6 TREATED BLOCKING AS SPECIFIED
FULLY ADHERED BASE
SHEET
EXISTING DECK
FULLY ADHERED
1/2" COVER BOARD
FULLY ADHERED TAPERED
POLY ISO RIGID INSULATION
R-25 MIN.
MECHANICALLY FASTENED 1/2"
COVER BOARD
EXISTING BRICK AT CHIMNEY
TREATED BLOCKING AS REQUIRED
TREATED 2 x 10
CANT STRIP AS
SPECIFIED
FILL VOID WITH OPEN
CELL SPRAY APPLIED
INSULATION
SCALE:
CHIMNEY FLASHING DETAIL
3" = 1'-0"
A110
SEALANT CONT.
EXISTING
ANGLE
EXISTING
STRUCTURE
ANCHOR @ 8" O.C. MAX SPACING
ANCHOR @ 8" O.C. MAX SPACING
REMOVE EXISTING
MORTAR TO A
DEPTH OF 1"
ROOF DRAIN INSERT SEE SHEET A100.
NOTE: ALL ROOFING DETAILS MUST MEET THE MINIMUM
REQUIREMENTS OF THESE DOCUMENTS, NRCA AND SHOP
DRAWINGS PROVIDED BY ROOFING SYSTEM
MANUFACTURER.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
BASE BID: DETAILS
A110 4 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
RD
6'-0"
'-0
WALK PAD
RD
LINE OF EXISTING BUILDING
EXISTING STEPS
5'-0"
'-6
SAW CUT EXISTING CONCRETE SIDEWALK
REMOVE EXISTING SIDEWALK
COMPLETE THIS AREA
PROVIDE 1/2" EXPANSION JOINT BETWEEN
EXISTING AND NEW CONCRETEPROTECT EXISTING SIDEWALK. PHOTOGRAPH
EXISTING CONDITIONS PRIOR TO START OF WORK.
CONTRACTOR IS RESPONSIBLE FOR CORRECTING
ANY DAMAGE TO EXISTING SIDEWALK.
24'-8" 24'-8"
'-6
REMOVE EXISTING SOILS TO A DEPTH OF 16 INCHES BELOW EXISTING ELEVATION AT THE
EXISTING STEP LOCATION. PROOF-ROLL AND COMPACT THE EXPOSED SUB-GRADE TO A
FIRM, STABLE CONDITION. SCARIFY AND RE-COMPACT THE EXISTING SOILS TO A MINIMUM
OF 95 PERCENT OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698,
EXISTING SOILS HAVE A BEARING CAPACITY OF 3500 P.S.F.
PLACE SELECT FILL IN UNIFORM LIFTS NOT EXCEEDING 6 INCHES LOOSE THICKNESS AND
COMPACT EACH LIFT TO A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY IN
ACCORDANCE WITH ASTM D698. PROVIDE COMPACTED SELECT FILL AS REQUIRED TO
ESTABLISH THE PROPER SUBGRADE ELEVATION FOR A 12-INCH-THICK REINFORCED
CONCRETE SLAB. THE COMPLETED SUBGRADE SHALL BE STABLE, LEVEL, AND CAPABLE
OF SUPPORTING THE EXTERIOR SINGLE-STORY MAINTENANCE STAIR AND ASSOCIATED
LOADS PRIOR TO PLACEMENT OF REINFORCING STEEL AND CONCRETE.
NOTIFY THE CONTRACTING OFFICERS REPRESENTATIVE OF ANY SOFT, WET, PUMPING,
ORGANIC, OR UNSUITABLE SOILS ENCOUNTERED DURING EXCAVATION. UNSUITABLE
MATERIALS SHALL BE REMOVED AND REPLACED WITH COMPACTED SELECT FILL AS
DIRECTED.
MATCH ELEVATION OF EXISTING
SLAB TO MAINTAIN STEP RISER
DIMENSION. PROVIDE 1/2"
EXPANSION JOINT CONT. AT
BASE OF EXISTING STAIR.
EXISTING SIDEWALK
PROVIDE 12" THICK CONCRETE FOUNDATION SLAB FOR STAIR.
REINFORCE WITH # 5 BARS @ 14" O.C. EACH WAY AT TOP AND
BOTTOM OF SLAB. MAINTAIN A MINIMUM OF 2" CLEAR BETWEEN
TOP, BOTTOM, AND SIDES OF SLAB AND REINFORCING.
SEE SHEET A210 FOR STAIR DETAILS SEE SHEET A210 FOR STAIR DETAILS
5" 4'-
4" 1'-
0" 4'-
4" 5"
5 1/2"4'-1 1/2"14'-1"
13'-9" (15 TREADS @ 11" WITH 1"
NOSING FOR FULL 12" TREAD DEPTH)
4'- 0"
C
LE
AR
4'-0" CLEAR
DWN
DWN
29'-5 3/8"
A210
4'-0"
4'- 0"
C
LE
AR
8'-9 1/2"4'-5" 5'-7 3/4" 14'-2 3/8" 4'-0 1/4"
4'- 3 5
/8"
LINE OF EXISTING BUILDING
LINE OF EXISTING BUILDING
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
BID OPTION #1: FLOOR PLANS
A200 5 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
BID OPTION #1
STAIR PLAN AT GRADE
1/8" = 1'-0"
A200 SCALE:
BID OPTION #1
STAIR PLAN AT ROOF LEVEL
1/8" = 1'-0"
A200SCALE:
BID OPTION #1
DEMOLITION AT EXISTING SIDEWALK
1/8" = 1'-0"
A200
1/4" X 4" TOE KICK AT BOTH SIDES OF LANDING
ROOF WALK PAD
FI
EL
D
VE
RI
FY
MA
X
RI
SE
R 9 1
/2"
PE
R
OS
HA
C
FR
.25
ST
AI
R
SH
AL
L N
OT
R
ES
T
ON
R
OO
F.
M
AI
NT
AI
N
MI
NI
MU
M
4" C
LE
AR
COMPACTED EXISTING SOILS AND SELECT FILL
SLOPE TO DRAIN
EXISTING SOILS
STEEL LEVELING SHIMS AS REQUIRED. 9000PSI GROUT
(4) 3/4"DIA x 8" ANCHOR BOLT WITH EXPANDER NUT PER COLUMN.
8'- 6 3
/8"
1'-0"
3'- 6"
3'- 0"
3'- 6"
EXISTING BUILDING
EXISTING STEP
1/2" EXPANSION
MATERIAL
4" x 4" X 1/4" STEEL POST
4" x 4" x 1/4" STEEL CROSS BRACING
1'- 0"
1'- 0"
1'- 0"
4'-0" O.C. MAX.
1 1/2" RAIL TYP.
1'- 0"
1'- 0"
1'- 0"
6"
4'-1 3/4"
STEEL BAR GRATING W-19-4 1 1/4"
x 3/16" W/ CHECKER NOSING &
WELD-IN SIDE PLATES
14 GA. SMOOTH CLOSURE TYP.
PLATE STRINGER 1/4x10 (UNO)
HANDRAILS WELDED TO
EXTERIOR OF PLATE
STRINGER
LANDING CHANNEL PER
MANUFACTURER
LANDING STEEL BAR GRATING
W-19-4 1 1/4" x 3/16" W/ CHECKER
NOSING & WELD-IN SIDE PLATES
LANDING CHANNEL PER
MANUFACTURER
LANDING STEEL BAR GRATING
W-19-4 1 1/4" x 3/16" W/ CHECKER
NOSING & WELD-IN SIDE PLATES
5x3x1/4 CONT. BTWN.
STRINGERS W/ (2) 5/8"~ x 1
1/2" A325 T.C. BOLTS ((1) BOLT
W/IN 4" OF EA. STRINGER)
PROVIDE 12" THICK CONCRETE FOUNDATION SLAB FOR STAIR. REINFORCE WITH # 5
BARS @ 14" O.C. EACH WAY AT TOP AND BOTTOM OF SLAB. MAINTAIN A MINIMUM OF
2" CLEAR BETWEEN TOP, BOTTOM, AND SIDES OF SLAB AND REINFORCING.
4" x 4" x 1/4" STEEL CROSS BRACING
1'- 0"
2'- 1 1
/2"
1/4" X 4" TOE KICK AT BOTH SIDES OF LANDING
1" CHAMEFER
TOP OF SLAB: 0'-0" (AT FINISH GRADE)
INTERMEDIATE LANDING: 9'-0"(FIELD VERIFY)
ABOVE TOP OF SLAB
TOP LANDING: 18'-0" (FIELD VERIFY)
ABOVE TOP OF SLAB
MINIMUM 4" OF COMPACTED
CRUSHED LIME STONE SELECT FILL
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
BID OPTION #1: STAIR SECTION / DETAILS
A210 6 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
BID OPTION #1
SECTION AT STAIR
3/4" = 1'-0"
A210
THIS REFERENCE DRAWING IS ATTACHED TO AID IN LAYOUT
OF TAPERED INSULATION. THE NEW TAPERED INSULATION
SYSTEM SHALL HAVE A MINIMUM SLOPE OF 1/4" PER 12"
NOTE JOIST BEARING ELEVATIONS
NOTE JOIST BEARING ELEVATIONS
NOTE JOIST BEARING ELEVATIONS
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1 ROOF REPLACEMENT DESIGN
DAWSON, GEORGIA
STRUCTURAL REFERENCE DRAWING
RF001
7 707/02/2026
REH
JLF
DRL FACILITIES ENGINEERING BRANCH
5106 SUNNYSIDE AVENUE
BELTSVILLE, MD 20705-5100
XXX
TP
XXX
DD
XX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
FOR REFERENCE ONLY
EXISTING ROOF STRUCTURE
1/8" = 1'-0"
RF001
| G100 |
| Sheets and Views |
| G100 |
| D100 |
| Sheets and Views |
| D100 |
| A100 |
| Sheets and Views |
| A100 |
| A110 |
| Sheets and Views |
| A110 |
| A200 |
| Sheets and Views |
| A200 |
| A210 |
| Sheets and Views |
| A210 |
| RF-001 |
| Sheets and Views |
| RF-001 |