About this file

This is a Statement of Work (SOW) for the Waunita Road Culvert project issued by the U.S. Department of Agriculture (USDA) Forest Service for the Gunnison Ranger District in Colorado. The contract requires the supply and delivery of a single-cell, precast, reinforced concrete box culvert designed to replace a failed road bridge spanning an ephemeral stream. The culvert must meet specific geometric constraints including a minimum interior width of 8 feet (greater than 8 feet preferred), a rise not exceeding 55 inches, a length between 35 and 40 feet, installation at a 45-degree angle to the road centerline with skewed end sections, and a tapered inlet throat. The contract includes an option for the contractor to supply compatible precast reinforced concrete wingwalls and headwalls for both upstream and downstream ends, or suitable prefabricated alternatives. All materials must be delivered to a pre-approved location within 45 miles (approximately 1 hour's drive) of Gunnison, Colorado.

The culvert must conform to current design standards including ASTM C 1433, ASTM C 1577, AASHTO M 259, and AASHTO M 273 specifications, and must be designed to support the FHWA HL-93 design load. Installation requires no in-situ foundation design; the structure will be installed on native or imported prepared soil bedding per FHWA FP24 section 209 standards and Forest Service Supplemental Specifications. No site geotechnical evaluation or minimum cover is required. Key deliverables at bid submission include geometric details, weight specifications, manufacturer drawings, shop drawings, certification test results, installation and structural specifications, and an estimated delivery date. A minimum of seven days prior to shipment, the contractor must provide shipping/freight details including delivery vehicle specifications, origin location, estimated shipping time, and delivery date. The target delivery date is no later than August 30, 2026. The contractor is responsible for on-time, undamaged delivery and must guarantee materials against damage during manufacturing, storage, loading, and transportation. Materials are subject to inspection and acceptance by designated USFS personnel, with rejected materials to be replaced within 14 days at no additional cost to the government.

View the file

Other files for this federal contract opportunity

Other files attached to Gunnison Ranger District- Pre-cast Concrete Culverts, newest first.
File Type Posted
Questions and Answers.pdf PDF
SF-30 Update Delivery Date-Amendment 2.pdf PDF
WaunitaRoadCulvert_SOW_Amended.pdf PDF
SF-30 Amendment- Concrete Culverts.pdf PDF
C04.1240LP26Q0077-GMUG Concrete Culverts.pdf PDF
C04.1240LP26Q0077-GMUG Concrete Culverts.pdf PDF
A04.Attachment 2 Waunita_Map_2.pdf PDF
A04.Attachment 2 WaunitaRoadCulvert_Drawing_PlanView.pdf PDF
A04.Attachment 2 FHWA_Culvert_WW_HW_Std601.pdf PDF
A04.Attachment 2 Waunita_Map_1.pdf PDF
A04.Attachment 2 WaunitaRoadCulvert_Drawing_ProfileView.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Department of Agriculture (USDA)

Statement of Work

Contents Project General Information

1.0 Scope of Work

2.0 Background

Contractor Requirements

3.0 Technical Requirements / Tasks

4.0 Deliverables / Schedule

Project Waunita Road Culvert

General Information

1.0 Scope of Work

The purpose of this contract is to supply a single-cell, precast, reinforced concrete box culvert to the specifications outlined below. This contract includes the option to supply reinforced, precast concrete wingwalls and headwalls (or a suitable prefabricated alternative) for both the upstream and downstream ends of the culvert that shall be compatible with the culvert supplied. All materials supplied must include delivery to a pre-determined/ pre-approved location not greater than 45 miles (or approximately 1 hour’s drive) outside of Gunnison, CO, pending delivery vehicle selection.

2.0 Background

This culvert is to replace a failed road bridge that spans an ephemeral stream in the Gunnison Ranger District. The crossing has specific geometry, installation, and loading constraints.

Abbreviations to be used in the following sections:

US = Upstream DS = Downstream RIC = Reinforced concrete

Contractor Requirements

3.0 Technical Requirements / Tasks

1. The site has specific geometric constraints which must be met by the culvert supplied. These geometric constraints include:

• 8' minimum interior width/span- greater than 8’ preferred

• Rise not to exceed 55"- assuming there are no cover requirements and no embedment

• 35’ minimum length- not to exceed 40’

• Culvert to be installed at a 45-degree angle to the centerline of the road- US and DS end sections must be skewed 45 degrees

• Box culvert shall be 4-sided

• Tapered inlet throat

2. The existing site has specific installation requirements which must also be met by the culvert supplied. These installation and structural constraints include:

• In-situ foundation design shall not be required- structure is to be installed on native or imported prepared soil bedding, with bedding, backfill, and compaction specifications conforming to FHWA FP24 section 209 “Structural Excavation and Backfill” standards and Forest Service Supplemental Specifications (FSSS) section 209 standards of the same name.

• Project site geotechnical evaluation shall not be required for design or installation.

• No minimum cover requirements- no cover shall be required, besides a wearing surface, if applicable- not to exceed 4” thick.

The culvert supplied must adhere to all applicable, current design standards and specifications, as identified below:

3. The structure has specific design and structural requirements, which must also be satisfied. These design standards and specifications include, but are not limited to:

• ASTM C 1433 Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers

• AASHTO M 259 Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers

• AASHTO M 273 Precast Reinforced Box Section for Culverts, Storm Drains, and Sewers with less than 2 feet of Cover Subject to Highway Loadings. LRFD Design Code

• ASTM C 1577 Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers According to AASHTO LRFD

• Culvert must be designed to support the FHWA HL-93 design load.

NOTE: No AASHTO LRFD Design Code exists. In the two AASHTO standards for box culverts, you will find a note stating, “If load–and-resistance factor design is required, then use ASTM C 1577.”

4. This requisition includes specific materials requirements, which must be met:

• Culvert must be made of reinforced precast concrete sections, meeting all applicable FHWA requirements and standards for concrete culverts in dry, cold-weather climates.

5. This requisition includes specific delivery constraints which must be met:

• Materials to be delivered on time, undamaged, and no later than the date specified in section 5.0.

• Materials delivery must be guaranteed against damage. The government shall not be held financially responsible for any damage occurring to the product(s) prior to delivery or during product manufacturing, storage, loading, hauling, or unloading.

• Materials shall be subject to inspection by designated USFS personnel prior to acceptance of materials. The government reserves the right to reject materials that do not meet the specifications and requirements outlined in this contract. Rejected materials shall be replaced within fourteen (14) days of the inspection of the rejected materials at no additional cost to the government.

• Materials delivery shall be at a pre-determined, pre-approved location not greater than 45 miles (or approximately 1-hour drive) outside of Gunnison, CO.

• Contractor shall provide delivery vehicle specifications no less than seven (7) days prior to product shipment so that an appropriate delivery location can be selected.

• Delivery location shall be selected by designated USFS personnel.

• Delivery vehicle(s) may be subject to weed inspection prior to entering National Forest Lands. Delivery vehicle(s) shall be reasonably clean and free of mud and foreign debris prior to entering National Forest Lands.

6. If the option to provide headwalls and wingwalls is to be exercised:

They shall conform to all current FHWA specifications for headwall and wingwalls design and materials and shall be the minimum size required to be compatible with the culvert supplied. Precast headwalls and wingwalls are recommended, but satisfactory alternatives will be considered.

See drawings provided for additional information.

5.0 Deliverables / Schedule

1. At the time of bid submission, to be included w ithin the bidding package, the contractor shall supply:

• Geometric details of the culvert including:

o Clear span (from interior wall to interior wall), Clear rise (from interior wall to interior wall), full length, section length (if applicable), skew of ends or end sections, and the thickness of each external side- for the culvert o Maximum and minimum (exterior) heights o Skew of end sections o All applicable interior and exterior angles- of headwalls and wingwalls (if applicable)

• Weight details of all sections, in tons or pounds.

• Manufacturer drawings, shop drawings, and all applicable certification test results.

• Manufacturer’s installation and structural specifications for all components to include compaction, bedding, backfill, and wearing surface details, as applicable.

• If optional bid items are included in bid package, submit all applicable documentation from the above list for the optional bid item.

• Estimated materials delivery date. Contractor shall advise USFS personnel if the target delivery date is not feasible, and provide a realistic estimated delivery date.

2. After contract award and a minimum of seven (7) days prior to shipment of supplies, the contractor shall:

• Supply the project COR all shipping/freight details, to include- at minimum:

o Delivery vehicle specifications (trailer length, axel spacing, and axel load) o Location of origin o Estimated travel/ shipping time o Estimated delivery date o Method of unloading

Designated USFS personnel will use this information to select an appropriate delivery location. USFS personnel will notify contractor of approved delivery location prior to shipment of supplies.

3. Target delivery date for no later than August 30, 2026:

• Contractor shall ensure designated USFS personnel are onsite at time of supplies delivery and unloading, for final inspection and acceptance.

• Materials shall be delivered and unloaded at the specified, pre-determined delivery location and time.

• Materials are subject to acceptance by USFS personnel upon delivery. If materials are deemed unacceptable by

USFS personnel upon unloading and final inspection, the contractor has no more than fourteen (14) days after the final inspection to replace rejected materials.

Table 1

Key Deliverables Item No. Deliverable Objective Due 1 Product/ supplies details Contractor shall provide all requested product dimensions and all available manufacturer’s drawings and specifications, for all products and supplies to be delivered. To be included in the contractor’s bid.

At time of bid submission

2 Shipping/ freight details

To include all requested logistical information No later than seven (7) days prior to supplies shipment

3 Single-cell, Precast RIC box culvert.

To meet or exceed all minimum requirements and specifications described in section 3.0 of SOW

See item 3.

2 Compatible headwalls and wingwalls

To meet or exceed all minimum requirements and expectations described in section 3.0 of SOW.

See item 3.

3 Materials delivery All requested supplies to be delivered to a predetermined delivery location, not greater than a 45-mile (or one-hour drive) radius outside of Gunnison, CO. Delivery location to be announced once delivery vehicle specifications are provided.

Delivery logistics and costs to account for loading and unloading of materials.

Targeted for August 30, 2026

Project
General Information
1.0 Scope of Work
2.0 Background
Contractor Requirements
3.0 Technical Requirements / Tasks
5.0 Deliverables / Schedule