The project involves removal and replacement of an existing chimney liner at the Forest Service administrative building located at 209 High Street, Collbran, CO 81624. The 1937-constructed building has historical value and houses multiple Forest Service employees year-round. The contractor must remove the existing chimney liner, insulation (if present), screen cap, support plate, and other applicable components, then properly dispose of all removed materials off Forest Service property in compliance with State and County regulations. The new chimney liner installation must conform to manufacturer specifications and include the following materials: a 6-inch (approximate) by 25-foot stainless steel rigid liner with field-verified pipe diameter, a screen cap, and an 18-inch by 18-inch support plate. All materials must meet minimum requirements of 316Ti or 316L stainless steel, be rated for temperatures up to 2100 degrees, and be rated for use on wood burning stoves and inserts, coal stoves, traditional masonry fireplaces, and oil or gas burning appliances. Fall protection is required to complete the work. The contractor must provide names of a qualified installer and an assigned project manager prior to award.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Department of Agriculture (USDA)

Statement of Work

Contents Project

General Information

1.0 Scope of Work

2.0 Background

Contractor Requirements

3.0 Technical Requirements / Tasks

4.0 Contractor’s Key Personnel

Attachment

Project Collbran Chimney New Liner

General Information

1.0 Scope of Work

This project is to replace the existing chimney liner, including screen cap, support plate and other parts as necessary to complete the chimney main liner replacement (connectors). This requirement includes the removal and disposal of replaced chimney parts.

2.0 Background

The Collbran Administrative Site was established in the 1930s. The administrative site is located at 209 High St, Collbran, CO 81624. The site serves as the duty station for multiple Forest Service employees all year round. The administrative building was constructed in 1937 and has historical value. The chimney gets inspected and maintenance on a yearly basis. The chimney in the building was inspected, and the liner was identified as needing replacement.

Contractor Requirements

3.0 Technical Requirements / Tasks

Remove existing chimney liner, insulation (if existing), screen cap, support plate and other parts as applicable.

Properly dispose of trash and debris material off Forest Service property per State/County regulations.

Install new chimney liner and needed parts per manufacturer specifications.

o Main materials to submit specifications or submittals:

6 in (approximate) by 25 ft stainless steel rigid liner – field verify pipe diameter

Screen cap 18” by 18” support plate.

o Material minimum requirements:

316Ti stainless teel or 316L stainless steel Rated for temperatures of up to 2100 degrees Rated for use on wood burning stoves and inserts, coal stoves, traditional masonry fireplaces, oil burning, gas burning appliances.

o Fall protection will be required to complete work.

4.0 Contractor’s Key Personnel

Provide names of qualified installer and an assigned project manager.

Attachment Pictures: