Building Shell Plans Rev 1-30-23 (3).pdf
PDF 12 MB Posted
- Solicitation number
- 11492
- Issued by
- Arlington County, Union Hall CDP, Virginia
About this file
The document titled "Building Shell Plans Rev 1-30-23 (3).pdf" contains plans related to ITB 2305 - HVAC Systems for Field Operations Office, a state and local contract opportunity in Augusta County, Virginia. The project involves the installation of HVAC systems in the building shell located at 846 Laurel Hill Road, Verona VA, as shown on the plans by Blueline dated June 10th, 2022.
The contract opportunity requires bidders to provide pricing and qualifications for the installation of the HVAC systems per the provided plans. No additional details are provided regarding specific product quantities, response dates, site visits, or contract term length. The contract will be awarded to a qualified vendor by the Augusta County jurisdiction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Tally | — | |
| ITB 2305 Shop HVAC.pdf | ||
| Building Shell Plans Rev 1-30-23 (3).pdf | ||
| ITB 2305 Shop HVAC.pdf | ||
| Bid Tally | — |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
VICINITY MAP
VCC 1005.3.2 EXC 10.15" PER OCCUPANT
2+
19,843 SQ. FT.
20,291 SQ. FT.
VCC 1103.1YES
REQUIRED DOOR WIDTH
NOT REQUIRED
PROVIDED EXITS
ACCESS PROVIDED FOR THE DISABLED
FIRE SEPARATION
VCC TABLE 1006.2.1
AND 1006.3.1REQUIRED EXITS STORAGE MEZZANINE
MAIN LEVEL
VCC TABLE 1004.1.2
191 (SEE LIFE SAFETY PLANS)OCCUPANT LOAD
VCC 907.1
PROVIDED PER SPRINKLER SYSTEM
NOT REQUIREDSMOKE DETECTORS
FIRE ALARM
1ACTUAL NUMBER OF STORIES ABOVE GRADE
1ALLOWABLE NUMBER OF STORIES ABOVE GRADE
31' - 6"
75'-0"
ACTUAL AREA
MAIN LEVEL
TOTAL
REQUIREDSPRINKLER SYSTEM
UNLIMITED
VCC TABLE 503; VCC 504.2
IIB
VCC 304.1, 306.3, 311.2, 311.3NON SEPARATED B / F-2 / S-1 / S-2
VCC 507.4
ACTUAL HEIGHT
CODE REQUIREMENTS
CODE COMPLIANCE
ALLOWABLE HEIGHT
REFERENCES
VCC TABLE 601
VCC TABLE 507.4
PER VCC 507.4 AND DUE TO
MEETING REQUIREMENTS
OF FIRE FLOW
ALLOWABLE AREA
CONSTRUCTION TYPE
OCCUPANCY TYPE
PROJECT BUILDING CODES
PLUMBING FIXTURE COUNT
FIXTURES REQUIRED FIXTURES PROVIDEDFIXTURE TYPE
WATER CLOSET
LAVATORY
DRINKING
FOUNTAIN
SERVICE SINK
1 PER 1,000; 1 REQUIRED
1 REQUIRED
3 PROVIDED
3 PROVIDED INCLUDING
2 UNISEX SEE BELOW
3 PROVIDED INCLUDING
1 UNISEX SEE BELOW
2 PROVIDED
1 PROVIDED
PLUMBING FIXTURES FOR: MIXED OCCUPANCY B (BUSINESS)
BASED ON 2018 IBC PLUMBING FIXTURE TABLE 2902.1
CALCULATIONS ARE BASED ON OCCUPANT LOAD
TOTAL OCCUPANCY:191 OCCUPANTS
ASSUMING 95 MEN AND 96 WOMEN.
448 SQ. FT.STORAGE MEZZANINE
URINALS* 4 PROVIDED*
* PER IPC 2018, SECTION 419.2: URINALS SHALL NOT BE SUBSTITUTED FOR
MORE THAN 67% OF WATER CLOSETS IN ASSEMBLY OCCUPANCIES AND NO
MORE THAN 50% IN OTHER OCCUPANCIES
PROJECT NUMBER: 01-20-075
PROJECT NAME: AUGUSTA COUNTY SERVICE AUTHORITY
NEW MAINTENANCE BUILDING
ADDRESS: 846 LAUREL HILL RD. VERONA, VA
PROJECT INFORMATION
CODES / STANDARDS
2018 VIRGINIA CONSTRUCTION CODE
2018 VIRGINIA PLUMBING CODE
2018 VIRGINIA ELECTRICAL CODE
2018 VIRGINIA MECHANICAL CODE
2018 VIRGINIA FUEL GAS CODE
2018 VIRGINIA ENERGY CONSERVATION CODE
2018 VIRGINIA FIRE PREVENTION CODE
BUILDING DESCRIPTION
ADMINISTRATION OFFICES & WAREHOUSE
THE INFORMATION CONTAINED BELOW WAS COMPILED BY AND
FOR THE EXCLUSIVE USE OF THE ARCHITECT IN THE DESIGN OF
HIS PORTION OF THE WORK. IT IS ALSO INTENDED TO IDENTIFY
TO THE CODE OFFICIAL THE ARCHITECT'S INTERPRETATION OF
THE CODE. THE INFORMATION IS EXCERPTED FROM THE CODE
IDENTIFIED BELOW UNLESS INDICATED OTHERWISE. IT IS
INTENDED TO IDENTIFY REQUIREMENTS FOR THIS STRUCTURE
PRIMARILY IN TERMS OF OCCUPANCY, CONSTRUCTION TYPE
AND EGRESS. MISCELLANEOUS OTHER ISSUES MAY ALSO BE
IDENTIFIED. THE INFORMATION IS NOT INTENDED TO INCLUDE
ALL APPLICABLE PORTIONS OF THE CODE OR OTHER
APPLICABLE CODES AND GOVERNING REGULATIONS. IT IS ALSO
NOT INTENDED TO DIMINISH THE IMPORTANCE OR RELEVANCE
OF OTHER PORTIONS OF CODES AND REGULATIONS THAT ARE
APPLICABLE TO THE WORK CONTAINED IN THE DRAWINGS AND
SPECIFICATIONS. CONSULTANTS, CONTRACTORS,
MANUFACTURERS AND OTHER PARTIES THAT HAVE OR WILL
PERFORM DESIGN OR CONSTRUCTION SERVICES ON THIS
STRUCTURE SHALL NOT RELY ON THIS INFORMATION IN THE
PERFORMANCE OF THEIR WORK. EACH SUCH PARTY SHALL BE
RESPONSIBLE FOR THEIR OWN REVIEW AND COMPLIANCE OF
CODES AND REGULATIONS.
STORAGE MEZZANINE
MAIN LEVEL
NOT REQUIRED
3 PROVIDED INCLUDING
1 UNISEX SEE BELOW
MEN: 1 PER 25 FOR FIRST 50
1 PER 50 FOR REMAINDER (50+)
3 REQUIRED
UNISEX: NOT REQUIRED 2 PROVIDED
WOMEN: 1 PER 25 FOR FIRST 50
1 PER 50 FOR REMAINDER (50+)
3 REQUIRED
MEN: 1 PER 40 FOR FIRST 80
1 PER 80 FOR REMAINDER (80+)
3 REQUIRED
WOMEN: 1 PER 40 FOR FIRST 80
1 PER 80 FOR REMAINDER (80+)
3 REQUIRED
UNISEX: NOT REQUIRED 2 PROVIDED
TOTAL: 6 REQUIRED 6 PROVIDED
TOTAL: 6 REQUIRED 6 PROVIDED
(540) 432-6272
WFS@MEIEGINEERINGINC.COM
WESLEY SIEVER
HARRISONBURG, VA 22802
& PLUMBING ENGINEER 1592 CF POURS DR.
MECHANICAL/ELECTRICAL MEI ENGINEERING, INC.
(540) 442-8787
BK@ENGSOLN.COM
BRIAN KOERNER
HARRISONBURG, VA 22802
1010 N MAIN STREET
STRUCTURAL ENGINEER ENGINEERING SOLUTIONS
(540) 437-1228
ACAMPBELL@BLUELINE.TEAM
ANNA CAMPBELL
HARRISONBURG, VA 22801
126 W. BRUCE STREET
ARCHITECT BLUE RIDGE ARCHITECTS, PC, A BLUELINE COMPANY
(540) 394-3214
SCOTT@PEED-BORTZ.COM
SCOTT BORTZ
CHRISTIANSBURG, VA 24073
20 MIDWAY PLAZA DR. #100
CLIENT PEED & BORTZ, LLC
PROJECT TEAM
THE ELECTRONIC DATA USED TO CREATE THESE DOCUMENTS IS
AVAILABLE IN DIGITAL FORM FOR THE PRICE OF $100 PER FILE.
RECIPIENT WILL ALSO BE REQUIRED TO SIGN AN ELECTRONIC DATA
RELEASE FORM.
Anna Sarnowska-Campbell
No. 014655
ALL DESIGNS, GRAPHICS AND DATA ON THIS SET OF DRAWINGS ARE THE INTELLECTUAL PROPERTY OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY AND HAVE BEEN CREATED AND DEVELOPED FOR THIS SPECIFIC PROJECT. USE OF ALL INTELLECTUAL PROPERTY BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE IS UNAUTHORIZED WITHOUT THE WRITTEN PERMISSION OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE PROJECT SITE, AND SHALL NOTIFY BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY OF ANY DISCREPANCIES FROM THE DIMENSIONS AND CONDITIONS SHOWN IN THIS SET OF DRAWINGS. IF DISCREPANCIES ARE FOUND BETWEEN ANY ELECTRONIC FILES AND THE SEALED ORIGINAL, THE SEALED ORIGINAL SHALL GOVERN.
COPYRIGHT: 2022
PROJ NO:
1/6/2022 BID DOCUMENTS
REVISED BID DOCUMENTS6/10/2022
6/10/2022
10/26/2022 3:09:11 PM
L
A U
R E
L H
IL
L R
D
V E
R O
N A
V
A
A U
G U
S T
A C
O U
N T
Y S
E R
V
IC
E A
U T
H O
R
IT
Y
CS
COVER SHEET
01-20-075
AUGUSTA COUNTY SERVICE AUTHORITY
846 LAUREL HILL RD. VERONA, VA
DRAWING INDEX
CS COVER SHEET
A-010 GENERAL NOTES / SCHEDULES
A-021 LEVEL 1 LIFE SAFETY PLAN
A-022 LEVEL 2 LIFE SAFETY PLAN
S-001 GENERAL NOTES
S-101 FOUNDATION PLAN
S-102 MEZZANINE FRAMING PLAN
S-201 FOUNDATION DETAILS
A-101 LEVEL 1 FLOOR PLAN
A-102 LEVEL 2 FLOOR PLAN
A-111 LEVEL 1 RCP
A-112 LEVEL 2 RCP
A-120 FINISH LEGEND AND SCHEDULE
A-121 FINISH PLANS
A-122 ROOF PLAN
A-201 BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-302 EXTERIOR WALL SECTIONS
A-303 WALL SECTIONS + DETAILS
A-401 ENLARGED PLANS / CASEWORK DETAILS
M-001 MECHANICAL SPECIFICATIONS
M-101 HVAC PLANS
M-102 HVAC SCHEDS. AND DETAILS
E-001 ELECTRICAL SPECIFICATIONS
E-002 ELEC. SCHEDS., PANELS, & RISER
E-003 ELEC. PANEL SCHEDULES
E-004 ELEC. RISERS AND FORMS
E-101 POWER PLANS
E-201 LIGHTING PLANS
E-301 CABLE TRAY / CONDUIT PLANS
E-401 ELECTRICAL SITE PLAN
P-001 PLUMBING SPECS., SCHEDS. & DETAILS
P-101 SANITARY / AIR PLAN & RISERS
P-201 WATER / GAS PLAN & RISERS
RENDERING FOR VISUALIZATION PURPOSED ONLY; NOT INTENDED FOR CONSTRUCTION
Mark Date Description
1 Date 1 ADDENDUM 1
BID DRAWINGS ARE EXCERPT FROM FULL SET OF PROJECT DOCUMENTS,
SO MAY DETAIL ADDITIONAL SCOPE OF WORK, NOT PERTINENT TO
SHELL BUILDING PROJECT. PROVIDE ONLY BIDS FOR BUILDING SHELL
(INCLUDING INSULATION), EXTERIOR DOORS, WINDOWS AND AWNINGS,
FOUNDATIONS, SLAB AND UNDER-SLAB PIPING.
SIZE AND LOCATION OF MECHANICAL & ELECTRICAL EQUIPMENT PADS &
TRENCHES ARE APPROXIMATE. VERIFY FINAL SIZE AND
LOCATION WITH FINAL EQUIPMENT REQUIREMENTS.
PROVIDE MASONRY CONTROL JOINT AT INSIDE CORNERS AND AS
INDICATED ON DRAWINGS.
ARCHITECTURAL FINISHED FLOOR ELEVATION 100'-0" IS EQUAL TO
FINISHED FLOOR ELEVATION 1246.00 INDICATED ON CIVIL DRAWINGS.
ALL WORK SHALL COMPLY THE REQUIREMENTS OF THE VIRGINIA
CONSTRUCTION CODE, 2015 EDITION. COMPLY WITH ALL FEDERAL, STATE
AND LOCAL ORDINANCES AND REGULATIONS AS APPLICABLE TO THIS
PROJECT.
THE DRAWINGS ARE DIAGRAMMATIC, INTENDING TO OUTLINE GENERAL
DESIGN REQUIREMENTS ONLY, AND ARE NOT INTENDED TO BE COMPLETE
IN ALL DETAILS. SPECIFIC IMPLEMENTATION OF THE DRAWINGS SHALL BE
THE RESPONSIBILITY OF EACH TRADE ENGAGED UPON THE WORK. THE
CONTRACTOR IS RESPONSIBLE FOR OVERALL COORDINATION.
BY ENTERING INTO CONTRACT, EACH CONTRACTOR REPRESENTS THAT
HE HAS THE SKILL AND EXPERT KNOWLEDGE TO EXECUTE THE WORK
REQUIRED, AND THAT THEY ARE LICENSED BY THE VIRGINIA DEPARTMENT
OF COMMERCE IN ACCORDANCE WITH THE LATEST REQUIREMENTS THE
CODE OF VIRGINIA, AS AMENDED.
EACH CONTRACTOR SHALL PROTECT HIS WORK AND EXISTING
CONSTRUCTION FROM DAMAGE DUE TO HIS OPERATION AND SHALL
REPLACE OR REPAIR, AS REQUIRED, ALL DAMAGED WORK TO THE
SATISFACTION OF THE OWNER.
TAKE MEASUREMENTS AND VERIFY WORKING CONDITIONS AT THE SITE
AND COORDINATE WITH THE DRAWINGS. VERIFICATIONS SHALL TAKE
PLACE BEFORE LAYING OUT OR PROCEEDING WITH WORK. THE
CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ERRORS, INCLUDING
THE COSTS OF CORRECTIVE WORK, RESULTING FROM HIS FAILURE TO
EXERCISE SUCH VERIFICATION.
CLEAN UP AND REMOVE SITE FROM DAILY ALL DEBRIS, AND LEAVE THE
WORK IN AN ORDERLY CONDITION, BROOM CLEAN.
ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD OR FACE
OF MASONRY, UNLESS OTHERWISE NOTED. VERIFY ALL DIMENSIONS IN
THE FIELD.
FIREBLOCKING:
MATERIALS: 2-INCH (NOMINAL) THICKNESS OF LUMBER WITH TIGHT
JOINTS, 2 THICKNESSES OF 1-INCH (NOMINAL) LUMBER WITH
BROKEN LAP JOINTS, OR 1 THICKNESS OF 23/32-INCH PLYWOOD OR OSB
PANEL WITH JOINTS BACKED BY SAME MATERIAL.
REQUIRED:
A. IN CONCEALED WALL SPACES AT THE CEILING & FLOOR OR
ROOF LEVELS.
B. AT CONNECTIONS BETWEEN HORIZONTAL & VERTICAL
SPACES, SUCH AS SOFFITS & DROPPED CEILINGS.
C. AT OPENINGS AROUND VENTS, PIPES, DUCTS AND OTHER
PENETRATIONS THROUGH CEILING AND FLOOR LEVELS.
D. WITHIN CONCEALED SPACES OF EXTERIOR WALL FINISH &
OTHER EXTERIOR ARCHITECTURAL
ELEMENTS AT MAXIMUM INTERVALS OF 20 FEET.
E. IN ANY SPACES BEHIND COMBUSTIBLE FINISH & TRIM AT
MAXIMUM INTERVALS OF 10 FEET.
GENERAL NOTES:
SUBMITTALS ARE NOT CONTRACT DOCUMENTS. THE PURPOSE OF
SUBMITTALS IS TO DEMONSTRATE THE WAY THE CONTRACTOR
INTENDS TO CONFORM TO THE DESIGN INTENT OF THE CONTRACT
DOCUMENTS.
SUBMITTALS NOT REQUIRED MAY BE RETURNED WITHOUT ACTION.
THE CONTRACTOR SHALL PROVIDE A SUBMITTAL SCHEDULE FOR
APPROVAL BY THE ARCHITECT. THE SUBMITTAL SCHEDULE SHALL
PROVIDE REASONABLE TIME FOR ARCHITECT REVIEW AND IN
SEQUENCE SUCH THAT NO DELAY IN THE WORK SHALL RESULT.
THE ARCHITECT WILL REVIEW SUBMITTALS FOR THE LIMITED
PURPOSE OF CHECKING CONFORMANCE WITH THE INFORMATION
GIVEN AND DESIGN INTENT.
THE CONTRACTOR SHALL REVIEW SUBMITTALS FOR COMPLIANCE
WITH THE CONTRACT DOCUMENTS PRIOR TO SUBMISSION TO THE
ARCHITECT.
THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK
PERTAINING TO A SUBMITTAL PRIOR TO RECEIPT OF THE SUBMITTAL
REVIEWED BY THE ARCHITECT.
THE WORK SHALL BE IN ACCORDANCE WITH REVIEWED SUBMITTALS.
HOWEVER, THE CONTRACTOR IS NOT RELIEVED OF RESPONSIBILITY
FOR DEVIATIONS FROM REQUIREMENTS OF THE CONTRACT
DOCUMENTS BY THE REVIEW OF SUBMITTALS BY THE ARCHITECT.
THE CONTRACTOR IS NOT RELIEVED OF RESPONSIBILITY FOR
ERRORS OR OMISSIONS IN SUBMITTALS BY THE ARCHITECTS REVIEW.
THE CONTRACTOR SHALL DIRECT SPECIFIC ATTENTION TO ITEMS
REQUIRING ARCHITECT SELECTIONS.
SUBMITTAL PROCEDURES:
ADA SIGNAGE MOUNTING:
1'-0"
A .F
.F
MEN WOMEN UNISEX RESTROOMS
MEN
HANDICAPPED
RESTROOM
ACCESSIBLE 1ST
FLOOR
WOMEN MEN UNISEX
WALL - SIGNAGE (TYP)
NOTE:
PICTOGRAMS AND/OR LETTERING ARE
NOT REQ'D ON DOOR-MOUNTED
SIGNAGE. WALL-MOUNTED SIGNAGE
TO BE LOCATED ON LATCH SIDE OF
DOOR CLEAR OF DOOR-SWING.
MOUNT AT 60" TO CENTERLINE OF
SIGN FROM FLOOR.
DOOR-
MOUNTED
SIGNAGE
MEN
LETTERING RAISED 1/32".
HEIGHT OF LETTERING
5/8" TO 2" MAX.
CORRESPONDING
GRADE 11 BRAILLE
UPPERCASE CHARACTERS
DOOR-MOUNTED SIGNAGE (TYP)
SHOP DRAWINGS REQUIRED FOR ACCESSIBLE SIGNAGE PLACEMENT
ALL SIGNAGE SHALL CONFORM TO:
VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2018:
VIRGINIA CONSTRUCTION CODE (VCC) 2018: SECTION 1111 SIGNAGE
VIRGINIA EXISTING BUILDING CODE (VEBC) 2018:
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ASAD) DATED SEPTEMBER 15,
2010: SECTION 703 SIGNS
ADA SIGNAGE MOUNTING NOTES:
LIGHT GAGE METAL FRAMING AS INDICATED, GALVANIZED AND CONFORMING TO ASTM A653.
STANDARD GYPSUM BOARD 5/8” THICK AT WALL AND CEILING LOCATIONS UNLESS NOTED OTHERWISE
USE MOISTURE RESISTANT GYPSUM BOARD BEHIND, ADJACENT TO, AND ABOVE FIXTURES WHICH USE WATER OR GENERATE STEAM.
INSTALL GYPSUM BOARD ACCORDING TO ASTM C840
FINISH TO GA-214 LEVEL 4 THROUGHOUT, EXCEPT:
A. LEVEL 2 ABOVE CEILINGS CONCEALED FROM VIEW
PROVIDE CONTROL JOINTS PER GA-216, APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS. NOTE THAT ALL CONTROL JOINTS SHALL BE PREMANUFACTURED OR FIELD FABRICATED FROM SUITABLE MATERIALS. A CONTROL JOINT SHALL BE INSTALLED WHERE A PARTITION, WALL, OR CEILING CROSSES A CONSTRUCTION JOINT (EXPANSION, SEISMIC, OR BUILDING CONTROL JOINT) IN THE SUPPORTING BUILDING STRUCTURE. CONTROL
JOINTS SHALL BE INSTALLED:
A. WHERE A WALL OR PARTITION RUNS IN AN UNINTERRUPTED STRAIGHT PLANE EXCEEDING 30 FT.
B. AT CEILINGS WITHOUT PERIMETER RELIEF, CONTROL JOINT SPACING SHALL NOT EXCEED 30 FT.
GYPSUM BOARD PARTITIONS
1. ALL PARTITION TYPES TO BE TYPE 1 - UNLESS NOTED OTHERWISE.
2. PROVIDE SLIP CONNECTION AT NON-BEARING PARTITIONS EXTENDING TO UNDERSIDE OF STRUCTURE - TYP.
3. 5/8" CEMENTITIOUS BACKER BOARD AT ALL TILE LOCATIONS, INCLUDING TILE BASE LOCATIONS.
4. DIAGONAL BRACE PARTITIONS ABOVE CEILING.
5. SEE FINISH SCHEDULE FOR APPLIED FINISHES OR ALTERNATE COMPONENTS TO PARTITION TYPES LISTED BELOW
6. PROVIDE MOISTURE RESISTANT G.W.B. AT JANITOR ROOMS, LOCKER ROOMS AND RESTROOMS UNLESS OTHERWISE NOTED.
7. F.R.T. PLYWOOD (PAINTED) FROM 1'-0" A.F.F. TO 9'-0" A.F.F. ON ALL WALLS IN SERVER ROOM.
8. PROVIDE STUD GAUGE AS REQUIRED BY CODE FOR SPAN HEIGHTS
PARTITION TYPE GENERAL NOTES
3 5/8" METAL STUD
FRAMING WITH
SOUND BATT
INSULATION
5/8" GYPSUM
BOARD
5/8" GYPSUM
BOARD
5/8" GYPSUM
BOARD
TOP OF WALL
PLAN
BOTTOM
OF WALL
1A
1B
TYPE 1 WITH GYPSUM
WALL BOARD ON ONE
SIDE AND NO SOUND
BATT INSULATION
5/8" GYPSUM
BOARD
5/8" GYPSUM
BOARD
5/8" GYPSUM
BOARD
TYPE 1 - EXTEND WALL TO
UNDERSIDE OF MEZZANINE
2A TYPE 2 - EXTEND WALL TO
ROOF DECK
EXTEND WALL 1' ABOVE
CEILING
6" METAL STUD
FRAMING WITH
SOUND BATT
INSULATION
EXTEND WALL 1' ABOVE
CEILING
5/8" GYPSUM
BOARD
PVC WALL PANELS
UP TO 14'-0" A.F.F.
6" METAL STUD
FRAMING
EXTEND WALL TO ROOF
DECK
PVC WALL PANELS
UP TO 14'-0" A.F.F.
5/8" GYPSUM
BOARD
5/8" GYPSUM
BOARD
1/2" MOISTURE
RESISTANT GYPSUM
BOARD ABOVE PVC
WALL PANELS
6" CMU GROUT
FILLED (1 COURSE)
1C
TYPE 1B - EXTEND WALL TO
UNDERSIDE OF MEZZANINE
WITH GYPSUM WALL BOARD ON
ONE SIDE AND NO SOUND BATT
INSULATION
DOOR SCHEDULE LEGEND (ABBREVIATIONS USED IN SCHEDULE)
PNT = PAINT WD= WOOD AN = ANODIZED
HM = HOLLOW METAL F = FLUSH ST= STEEL
V = VISION PANEL OH = OVERHEAD SV = FACTORY PRE-FINISHED
ANSI FUNCTIONS
F-36 PRIVACY LOCK
F-75 PASSAGE SET
F-81 ENTRANCE LOCK
F-82 OFFICE LOCK
F-84 CLASSROOM LOCK
F-86 STORAGE LOCK
DOOR SCHEDULE GENERAL NOTES
1. GLAZING IN DOORS SHALL BE TEMPERED U.N.O.
2. GLAZING IN EXTERIOR DOORS TO BE INSULATED
3. GLAZING SIZES SHALL COMPLY WITH THE SIZE LIMITATIONS OF NFPA 80
4. EXTERIOR METAL FRAMES AND DOORS TO BE INSULATED.
5. HOLLOW METAL FRAMES TO BE FACE-WELDED
6. CONTRACTOR TO COORDINATE ALL JAMB DEPTHS WITH WALL THICKNESS
7. EXTERIOR ROUGH OPENINGS TO BE SEALED WITH SEALANT AND BACKER-ROD
8. PROVIDE COMMERCIAL GRADE DOOR HARDWARE
9. DOOR HARDWARE TO COMPLY WITH GRASPABILITY AND MOUNTING REQUIREMENTS PER IBC SECTION 1008.
10. PROVIDE REMOVABLE CORES AND KEY TO OWNER'S SYSTEM. LOCKS TO BE SAME MANUFACTURER AS KEY
SYSTEM.
11. PROVIDE SOLID F.R.T. WOOD BLOCKING AT WALL STOP LOCATIONS
12. PROVIDE WEATHERSTRIPPING, DOOR SWEEPS, THRESHOLD AND DRIP CAPS AT EXTERIOR DOORS
DOOR SCHEDULE REMARKS:
1. CASED OPENING
2. PUSH-PULL
3. OVERHEAD SECTIONAL DOOR WITH MANUAL CHAIN OPERATOR
4. PROVIDE CARD READER ELECTRIC STRIKE SYSTEM
5. PROVIDE DOOR BELL SYSTEM WITH PROGRAMMABLE ACCESS AUTHORITY FROM NEWMAN OFFICE 108
6. PROVIDE DOOR RELEASE BUTTON IN NEWMAN OFFICE 108
7. OVERHEAD SECTIONAL DOOR TO BE MOTORIZED
8. PROVIDE ELECTRIC STRIKE, POWER TRANSFER THRU DOOR, POWER SUPPLY, REQUEST TO EXIT FEATURE BUILT
INTO LOCK, DOOR CONTACTS AND DOOR POSITION SWITCH ON EACH LEAF
9. PROVIDE DOOR HOLD OPEN
10. PROVIDE ROUGH-IN FOR FUTURE CARD READER ELECTRIC STRIKE SYSTEM
11. ALUMINUM STOREFRONT SUPPLIER TO PROVIDE ALL REQUIRED DOOR HARDWARE EXCEPT CYLINDERS.
CYLINDERS ARE TO BE BY THE HARDWARE SUPPLIER.
12. PEMB MANUFACTURER PROVIDE INSULATED DOOR & FRAME, HINGES, CLOSERS, WEATHERSTRIPPING, STANDARD DRIP/JAMB FLASHING & THRESHOLDS. PEMB TO PREP/REINFORCE FOR SCHEDULED LOCKS, ACCESS CONTROL & EXIT DEVICES PROVIDED BY DOOR HARDWARE SUPPLIER. PERMANENT CORES AND KEYS PROVIDED
BY OWNER.
DOOR AND HARDWARE NOTES
INDICATES
TEMPERED GLAZING
REQUIRED
OH: SECTIONAL OVERHEAD DOOR SF
T
2" DOOR 2"
D O
O R
F V
T
8" 8"
HM1
DOOR ELEVATION TYPE DOOR FRAME TYPE
T
8"
STOREFRONT TYPES INTERIOR WINDOW TYPES
M
A X
C L T
TT T
NOTE: COORDINATE # OF
VISION WINDOWS W/
OVERALL WIDTH OF DOOR. TYPICAL MOUNTING HEIGHTS
T O
P O
F B
O X
M A
X
1'-0"
LIGHT SWITCH /
FIRE PULL
OUTLET
B O
T T
O M
O F
B O
X
T O
B O
T T
O M
O F
S T
R O
B E
T O
STROBE
5/8" G.W.B. - PTD.
DOOR PANEL
HOLLOW METAL
FRAME -
PAINTED
DOOR FRAME
ANCHOR
PARTITION FRAMING PER
PARTITION TYPES
PAINTABLE SEALANT ENTIRE
PERIMETER OF DOOR FRAME
U.N.O.
4"
8'-0"
2'-5"3'-2"2'-5"
T
T
T
T
T
SF1
3'-0"
SF2
3'-0"
6'-0"
3'-0"
SF3
C
HOLLOW METAL
FRAME
5'-6"
B
HOLLOW METAL
FRAME
SLIDING PASS
THROUGH WINDOW
SS-02 COUNTER
T
3'-4"
SF4
1. LOCKSETS/LATCHSETS: SCHLAGE ND SERIES, COMMERCIAL GRADE 1, HEAVY DUTY CYLINDRICAL LOCKSET, LEVER STYLE & FINISH: SCHLAGE RHODES, 626 SATIN CHROMIUM FINISH
2. ELECTRIC STRIKES: ASSA ABLOY HES 1600CLB OR SIMILAR AS REQUIRED FOR INSTALL LOCATION. TO BE
INSTALLED FAIL SECURE AND BE TIED TO THE BUILDING GENERATOR BACKUP.
3. PERMANENT CORES & KEYS PROVIDED BY OWNER.
4. HINGES: HAGER ECBB1100 US26D, FULL MORTISE, FIVE KNUCKLE, BALL BEARING, STANDARD WEIGHT.
PROVIDE ECBB1101NRP US32D AT EXTERIOR DOORS
5. CLOSERS: HAGER 5200 SERIES, ALUMINUM FINISH
6. DOOR SWEEPS, WEATHERSTRIP, THRESHOLD & DRIP CAPS: HAGER
7. FLOOR & WALL STOPS: IVES
8. EXTERIOR EXIT DEVICES ON H MTL DOORS: VON DUPRIN 99 SERIES WITH RIM CYLINDER. COORDINATE WITH
OWNER SPECIFIED LOCKSET.
DOOR HARDWARE SPECIFICATIONS
STANDARD SHOP-FABRICATED STEEL FRAMES, CONFORMING TO ANSI A250.8
A. STEEL EXTERIOR: 16GA GALVANIZED TO ASTM A653M
B. STEEL INTERIOR: 16GA COLD-ROLLED STEEL
C. FACTORY FINISH: PRIMER, ANSI A250.10 RUST-INHIBITIVE TYPE
FABRICATE FRAMES AS FACE-WELDED UNITS UNLESS NOTED OTHERWISE
FABRICATE WITH HARDWARE REINFORCEMENT PLATES WELDED IN PLACE
NOT USED
PROVIDE THREE SINGLE SILENCERS FOR SINGLE DOORS ON STRIKE SIDE AND TWO SINGLE SILENCERS
ON FRAME HEAD AT DOUBLE DOORS.
PROVIDE WEATHERSTRIPPING WHERE INDICATED IN DOOR SCHEDULE; ALUMINUM WITH NEOPRENE OR
SILICONE SEALS
COORDINATE JAMB DEPTH WITH WALL THICKNESS
COORDINATE FABRICATION AND INSTALLATION WITH HARDWARE REQUIREMENTS
INSTALL PLUMB AND LEVEL FOR EASY AND SMOOTH OPERATION
STANDARD HOLLOW METAL FRAMES
SOLID CORE, AWI SECTION 9, 1 ¾” THICK, EXTRA HEAVY DUTY, PREMIUM GRADE
FINISHED FACE: WOOD VENEER, PLAIN SLICED WHITE OAK, BOOK & RUNNING
MATCHED, PRE-FINISHED PER MANUFACTURER'S STANDARD OPTIONS
FACING ADHESIVE: TYPE II – WATER RESISTANT
NOT USED
FINISH WORK IN ACCORDANCE WITH AWI SECTION 5, PREMIUM GRADE
GLAZING STOPS: WOOD, MATCH DOOR FINISH
INSTALL PER AWI AND MANUFACTURER’S REQUIREMENTS, PLUMB AND LEVEL
PROTECT FROM DAMAGE DURING CONSTRUCTION, REPAIR OR REPLACE DAMAGED
FINISHES
WOOD DOORS
1. DOOR PANELS, SHEET STEEL ANSI A250.8; HOLLOW METAL, 16GA A60 EXTERIOR, 18GA
COLD ROLLED STEEL INTERIOR 1 ¾” THICK, FIELD PAINTED
2. INSULATE EXTERIOR DOORS, POLYURETHANE FOAM TO R-2.4 MINIMUM
3. FABRICATE DOORS WITH HARDWARE REINFORCEMENT WELDED IN PLACE
4. INSTALL DOORS PER ANSI A250.11
METAL DOORS
1. TEMPERED GLASS: ASTM C1048, TYPE 1 TRANSPARENT FLAT, QUALITY Q3, FULLY
TEMPERED, FLOAT GLASS
2. ALL EXTERIOR LOCATIONS TO BE INSULATED; 1” TOTAL UNIT THICKNESS
A. U-FACTOR: 0.38 MINIMUM (ENTRANCE DOORS: 0.77 MINIMUM)
B. SHGC: 0.40 MINIMUM
3. SEALANTS: ELASTOMERIC MATERIAL COMPATIBLE WITH ADJACENT MATERIALS, ASTM
C920
4. GASKETS: RESILIENT EXTRUDED SHAPE, ASTM C509
5. INSTALL ACCORDING TO GANA GLAZING MANUAL
GLAZING
1. DESIGN AND SIZE COMPONENTS TO WITHSTAND LOADING CAUSED BY POSITIVE
AND NEGATIVE WIND PRESSURE ACTING NORMAL TO THE PLANE OF WALL,
INCLUDING BUILDING CORNERS. SEE S-001 FOR DESIGN WIND LOAD
2. DESIGN AND SIZE GLASS LOCATED LESS THAN 60 FEET ABOVE GRADE TO
WITHSTAND (LARGE/SMALL) MISSILE IMPACT TEST.
3. ALUMINUM FRAME: EXTRUDED ASTM B221, THERMALLY BROKEN, CLEAR
ANODIZED FINISH
4. MULLIONS: PROFILE AS INDICATED IN THE DRAWINGS, FINISH TO MATCH
STOREFRONT DOORS
5. DOORS: ALUMINUM FRAMED GLASS DOORS, STANDARD THICKNESS, STILE AND
RAIL WIDTH AS INDICATED IN DOOR TYPES.
6. PROVIDE STANDARD RIM TYPE EXIT DEVICE
7. GLAZING AS SPECIFIED
8. BRACKETS AND REINFORCEMENTS FROM HIGH-STRENGTH ALUMINUM, OR
STEEL WHERE REQUIRED
9. FASTENERS AND ACCESSORIES COMPATIBLE WITH ADJACENT MATERIALS,
STAINLESS STEEL WHERE EXPOSED.
10. FURNISH MANUFACTURER’S STANDARD HARDWARE INCLUDING
WEATHERSTRIPPING, SILL SWEEPS AND FLASHINGS, THRESHOLDS, AND
HINGES
11. SEAL THE PERIMETER PER MANUFACTURER’S REQUIREMENTS.
12. INSTALL WALL SYSTEM IN ACCORDANCE WITH AAMA SPECIFICATIONS MANUAL
AND IN PROPER RELATION TO WALL FLASHING AND ADJACENT CONSTRUCTION.
13. PROVIDE ALL REQUIRED DOOR HARDWARE EXCEPT CYLINDERS
ALUMINUM STOREFRONT
1. INSULATED STEEL SECTIONAL OVERHEAD DOOR
A. DOOR ASSEMBLY:
i. PANEL THICKNESS: 1-3/8 INCHES
ii. EXTERIOR STEEL: .015 INCH, TEXTURED, ASTM 653
iii. END STILES: 20 GAUGE
iv. SPRING COUNTERBALANCE SIZED TO WEIGHT OF DOOR
v. HIGH CYCLE SPRING - 100K DUTY CYCLE, ASTM 229
vi. MIN. R-VALUE OF 13
vii. PROVIDE STANDARD SIZE VIEW WINDOWS AS INDICATED
B. FINISH AND COLOR: PROVIDE STANDARD TWO COAT BAKED-ON POLYESTER
C. LOCK: PROVIDE SLIDE LOCK WITH INTERLOCK SWITCH FOR AUTOMATIC
OPERATOR WHERE MOTORIZED DOORS ARE INDICATED.
D. WEATHERSTRIPPING: PROVIDE FULL PERIMETER SEAL OF THE OPENING
INCLUDING SECTION JOINT SEAL, TRACK-MOUNTED SIDE SEAL, VINYL TOP
SEAL AND FLEXIBLE VINYL ASTRAGAL ON BOTTOM EDGE
E. TRACK:
i. HIGH LIFT
ii. TRACK SIZE AS REQUIRED FOR APPLICATION
F. OPERATOR:
i. ELECTRIC MOTOR OPERATION, AS INDICATED, WITH REQUIRED
ENTRAPMENT PROTECTION PER UL 325/2010. OPERATOR CONTROLS
TO BE PUSH-BUTTON TYPE, INTERIOR SURFACE MOUNT
ii. PROVIDE MANUAL CHAIN HOIST OTHERWISE
OVERHEAD DOOR SPECIFICATIONS
1. CONCRETE CURING:
A. 'WET' CURE CONCRETE BY USE OF A MOISTURE-RETAINING COVERING
APPROVED BY THE LIQUID DENSIFIER AND SEALER MANUFACTURER
B. LIQUID DENSIFIER AND SEALER: EUCO DIAMOND HARD
i. APPLY WITH HIGH-VOLUME, LOW-PRESSURE SPRAYER, THEN SCRUB
INTO CONCRETE SURFACE PER MANUFACTURER'S SPECIFICATIONS
ii. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR COMPLETE
APPLICATION AND SLAB FLUSH/CLEAN PROCEDURES
SEALED CONCRETE SPECIFICATIONS
5'-0"
HOLLOW METAL
FRAME
A
T
Anna Sarnowska-Campbell
No. 014655
ALL DESIGNS, GRAPHICS AND DATA ON THIS SET OF DRAWINGS ARE THE INTELLECTUAL PROPERTY OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY AND HAVE BEEN CREATED AND DEVELOPED FOR THIS SPECIFIC PROJECT. USE OF ALL INTELLECTUAL PROPERTY BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE IS UNAUTHORIZED WITHOUT THE WRITTEN PERMISSION OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE PROJECT SITE, AND SHALL NOTIFY BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY OF ANY DISCREPANCIES FROM THE DIMENSIONS AND CONDITIONS SHOWN IN THIS SET OF DRAWINGS. IF DISCREPANCIES ARE FOUND BETWEEN ANY ELECTRONIC FILES AND THE SEALED ORIGINAL, THE SEALED ORIGINAL SHALL GOVERN.
COPYRIGHT: 2022
PROJ NO:
1/6/2022 BID DOCUMENTS
REVISED BID DOCUMENTS6/10/2022
6/10/2022
10/26/2022 3:09:00 PM
L
A U
R E
L H
IL
L R
D
V E
R O
N A
V
A
A U
G U
S T
A C
O U
N T
Y S
E R
V
IC
E A
U T
H O
R
IT
Y
A-010
GENERAL NOTES /
SCHEDULES
01-20-075
DOOR SCHEDULE
MARK WIDTH HEIGHT
DOOR FRAME
RATING
PANIC
DEVICE CLOSER
ANSI
FUNCTION REMARKSTYPE MATERIAL FINISH TYPE MATERIAL FINISH
101 3'-0" 7'-0"
102 3'-0" 7'-0"
103 3'-0" 7'-0"
104 3'-0" 7'-0" SF AL AN AL AL AN X X F-81
104A 3'-0" 7'-0"
105 3'-0" 7'-0"
106 3'-0" 7'-0"
107 3'-0" 7'-0"
107A 3'-0" 7'-0" SF AL AN AL AL AN X X F-81
108 3'-0" 7'-0"
108A 3'-0" 7'-0"
109 3'-0" 7'-0"
110 3'-0" 7'-0"
111 3'-0" 7'-0"
112 3'-0" 7'-0"
113 3'-0" 7'-0"
114 3'-0" 7'-0"
115 3'-0" 7'-0"
116 3'-0" 7'-0"
117 3'-0" 7'-0"
118 3'-0" 7'-0"
119 3'-0" 7'-0"
120 3'-0" 7'-0"
121 3'-0" 7'-0"
122 3'-0" 7'-0"
122A 3'-0" 7'-0"
123 3'-0" 7'-0"
123A 3'-0" 7'-0"
123B 3'-0" 7'-0"
123C 3'-0" 7'-0"
123D 3'-0" 7'-0"
124 3'-0" 7'-0"
124A 3'-0" 7'-0"
124B 3'-0" 7'-0"
124C 3'-0" 7'-0"
125A 3'-0" 7'-0"
125B 3'-0" 7'-0" SF AL AN AL AL AN X X F-81
125C 3'-0" 7'-0"
126A 3'-0" 7'-0"
126B 3'-0" 7'-0"
126C 3'-0" 7'-0"
126D 12'-0" 12'-0"
126E 12'-0" 12'-0"
126F 12'-0" 12'-0"
127A 3'-0" 7'-0"
127B 10'-0" 10'-0"
127C 10'-0" 10'-0"
128 3'-0" 7'-0"
129 3'-0" 7'-0"
130 3'-0" 7'-0"
131A 3'-0" 7'-0"
131B 3'-0" 7'-0"
132A 3'-0" 7'-0"
132B 12'-0" 14'-0"
132C 12'-0" 14'-0"
132D 14'-0" 14'-0"
132E 12'-0" 14'-0"
132F 12'-0" 14'-0"
132G 14'-0" 14'-0"
133A 3'-0" 7'-0"
133B 3'-0" 7'-0"
133C 14'-0" 14'-0"
133D 14'-0" 14'-0"
F WD SV HM1 HM PNT X F-36
- - - HM1 HM PNT 1
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
OH ST PNT - - PNT 7
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
F WD SV HM1 HM PNT X F-86 4
F WD SV HM1 HM PNT X F-86 4
F WD SV HM1 HM PNT X F-86 4
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT X F-82
F WD SV HM1 HM PNT X - 2
F WD SV HM1 HM PNT X F-75
F WD SV HM1 HM PNT X - 2
F WD SV HM1 HM PNT X - 2
F WD SV HM1 HM PNT F-86
V WD SV HM1 HM PNT X X F-82 9
F WD SV HM1 HM PNT F-82
V WD SV HM1 HM PNT X X F-82 9
F WD SV HM1 HM PNT F-86
V WD SV HM1 HM PNT X F-82
V WD SV HM1 HM PNT X F-82
V WD SV HM1 HM PNT X X F-81 4
V WD SV HM1 HM PNT X X F-81 4
V ST PNT HM1 HM PNT X X F-81 4, 12
V ST PNT HM1 HM PNT X F-82
V ST PNT HM1 HM PNT X F-75
OH ST PNT - - PNT 7
V ST PNT HM1 HM PNT X X F-81 4,5,12
F ST PNT HM1 HM PNT X F-36
F ST PNT HM1 HM PNT F-86
V ST PNT HM1 HM PNT F-82
V ST PNT HM1 HM PNT X X F-81 4,12
V ST PNT HM1 HM PNT X F-75
V ST PNT HM1 HM PNT X X F-81 4, 12
V ST PNT HM1 HM PNT X X F-81 4,12
V ST PNT HM1 HM PNT X F-75
1 1/2" = 1'-0"
DETAIL TYPICAL DOOR JAMB
- - - HM1 HM PNT 1
OH ST PNT - - PNT 3
OH ST PNT - - PNT 7
OH ST PNT - - PNT 7
OH ST PNT - - PNT 3
OH ST PNT - - PNT 3
OH ST PNT - - PNT 3
OH ST PNT - - PNT 7
OH ST PNT - - PNT 7
OH ST PNT - - PNT 3
OH ST PNT - - PNT 7
OH ST PNT - - PNT 7
4,5,8, 11
4,8,11
V WD SV HM1 HM PNT X X F-81 6
F WD SV HM1 HM PNT F-82
- - - HM1 HM PNT 1
- - - HM1 HM PNT 1
- - - HM1 HM PNT 1
8,10, 11
Mark Date Description
1 Date 1 ADDENDUM 1
175 SF
KELLER
174 SF
MADER
379 SF
F&M CREWS
IT/ SCADA
MECH.
SPRINKLER
TLT.
177 SF
ROACH
124 SF
DRUM
LOBBY
124 SF
NEWMAN
129 SF
HAMMER
128 SF
BUTLER
4955 SF
WAREHOUSE
2203 SF
F&M SHOPS
LNDRY
WOMEN'S
LOCKER
1047 SF
WASH BAY
3491 SF
GARAGE BAYS
TLT.
232 SF
PARTS STOR.
93 SF
OFFICE
LOBBY
EXIT ACCESS TRAVEL DISTANCE
76'-4"
FEC
FEC
119 SF
DUNCAN
1 OCCUPANT 1 OCCUPANT
TABULATED: 4 OCCUPANTS
@ 100 SF / PERSON
ACTUAL: 6 OCCUPANTS
1 OCCUPANT
1 OCCUPANT
77 OCCUPANTS
@ 20 SF / PERSON
TABULATED:
7 OCCUPANTS
@ 100 SF / PERSON
ACTUAL: 10 OCCUPANTS
10 OCCUPANTS
@ 500 SF / PERSON
22 OCCUPANTS
@ 100 SF / PERSON
1 OCCUPANT
1 OCCUPANT
@ 300 SF / PERSON
35 OCCUPANTS
@ 100 SF / PERSON
11 OCCUPANTS
@ 100 SF / PERSON
FEC
FEC
FEC
440 +4
8.46" 32"
57 OCC.
4.01" 32"
27 OCC.
2.23" 32"
15 OCC.
11 11
1.63" 32"
11 OCC.
4.3" 32"
29 OCC.
18+11
1 OCCUPANT 1 OCCUPANT 1 OCCUPANT 1 OCCUPANT
8 OCCUPANTS
@ 15 SF / PERSON
4 = [(1+1+6) / 2] = 4
11 = [22 / 2] = 11
17 = [35 / 2] = 188+17+1+1 17
FDC
123 SF
MCCRAY
1 OCCUPANT
1 OCCUPANT
109 SF
BUCK
JAN.
122A
MEN'S LOCKER
6.53" 32"
44 OCC.
FEC
119 SF
BREAK
COPY
STOR.
670 SF
FOPS CREW
COMMON PATH OF TRAVEL
58'-2"
E X
IT
A
C C
E S
S T
R A
V E
L D
IS
T
A N
C E
'-2
EXIT ACCESS TRAVEL DISTANCE
64'-4"
EXIT ACCESS TRAVEL DISTANCE
93'-0"
LIFT LIFT
1520 SF
TRAINING
39 +8+1+1=50 7= [(10+1+1+1) / 2] =6
(6
1.19" 32"
8 OCC.
LIFE SAFETY PLAN GENERAL NOTES
1. FIRE EXTINGUISHERS AND CABINETS ARE INDICATED ON THIS SHEET THUS:
DISTANCE TO NEAREST FIRE EXTINGUISHER: 50' FIRE EXTINGUISHERS TO BE
RATED WITH CAPACITY OF 2A:10B:C U.N.O. (MINIMUM) OR GREATER
PORTABLE FIRE EXTINGUISHER SHALL NOT BE OBSTRUCTED OR OBSCURED
FROM VIEW. WHERE VISUAL OBSTRUCTION CANNOT BE COMPLETELY
AVOIDED, PROVIDE MEANS TO INDICATE LOCATIONS OF EXTINGUISHERS
2. EXIT SIGNS ARE INDICATED ON THIS SHEET THUS:
3. 44" WIDE EGRESS PATH IS INDICATED THUS:
4. CONTRACTOR TO FURNISH AND INSTALL KNOX BOX. LOCATION TO BE DETERMINED
BY FIRE MARSHALL PRIOR TO INSTALLATION.
5. PROVIDE FIRE DEPARTMENT SIAMESE CONNECTIONS ON WALL OR POST AS
REQUIRED BY SPRINKLER SYSTEM DESIGN.
FDC LOCATION FOR SPRINKLER ROOM ONLY INDICATED ON THIS SHEET THUS:
NOTE: ADDITIONAL FDC LOCATIONS NOT INDICATED ON THIS SHEET MAY BE
REQUIRED. ALL LOCATIONS TO BE REVIEWED AND APPROVED BY THE FIRE
MARSHALL PRIOR TO INSTALLATION. FDC LOCATIONS TO BE CLEARLY
MARKED AND VISIBLE.
6. PROVIDE A DEDICATED HYDRANT LOCATED WITHIN 50 FEET OF
EACH FDC. HYDRANT LOCATION TO BE APPROVED BY FIRE
MARSHALL PRIOR TO INSTALLATION.
7. COORDINATE EGRESS LIGHTING WITH ELECTRICAL DRAWINGS
8. SEE COVER SHEET FOR CODE COMPLIANCE TABLE
9. COMMON PATH OF EGRESS TRAVEL (<100)
INDICATED THUS:
10. EXIT ACCESS TRAVEL DISTANCE (<250)
INDICATED THUS:
11. EGRESS DOOR TAG KEY:
A. FIRE EXTINGUISHER (UNLESS NOTED OTHERWISE):
a. LARSEN MANUFACTURING COMPANY MODEL MP5
B. FIRE EXTINGUISHER CABINET:
a. LARSEN MANUFACTURING COMPANY MODEL 2409-R3 SEMI-RECESSED
WITH 2 1/2" ROLLED EDGE TRIM FULL CLEAR ACRYLIC DOOR WITH
VERTICAL RED LETTERING
C. INSTALLATION:
a. PLACE EXTINGUISHERS AND ACCESSORIES IN CABINETS WHERE
INDICATED IN THE DRAWINGS
FIRE PROTECTION SPECIALTIES:
FEC
USE GROUP KEY PLAN:
# OCC.
# OF OCCUPANTS EXITING
MINIMUM REQUIRED CLEAR
EXIT WIDTH
PROVIDED CLEAR
EXIT WIDTH
EXITING DIRECTION
B USE GROUP S-2 USE GROUP
F-2 USE GROUP
S-1 USE GROUP
Anna Sarnowska-Campbell
No. 014655
ALL DESIGNS, GRAPHICS AND DATA ON THIS SET OF DRAWINGS ARE THE INTELLECTUAL PROPERTY OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY AND HAVE BEEN CREATED AND DEVELOPED FOR THIS SPECIFIC PROJECT. USE OF ALL INTELLECTUAL PROPERTY BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE IS UNAUTHORIZED WITHOUT THE WRITTEN PERMISSION OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE PROJECT SITE, AND SHALL NOTIFY BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY OF ANY DISCREPANCIES FROM THE DIMENSIONS AND CONDITIONS SHOWN IN THIS SET OF DRAWINGS. IF DISCREPANCIES ARE FOUND BETWEEN ANY ELECTRONIC FILES AND THE SEALED ORIGINAL, THE SEALED ORIGINAL SHALL GOVERN.
COPYRIGHT: 2022
PROJ NO:
1/6/2022 BID DOCUMENTS
REVISED BID DOCUMENTS6/10/2022
6/10/2022
10/26/2022 3:09:04 PM
L
A U
R E
L H
IL
L R
D
V E
R O
N A
V
A
A U
G U
S T
A C
O U
N T
Y S
E R
V
IC
E A
U T
H O
R
IT
Y
A-021
LEVEL 1 LIFE
SAFETY PLAN
01-20-075
3/32" = 1'-0"
LEVEL 1 LIFE SAFETY PLAN
FDC
Mark Date Description
1 Date 1 ADDENDUM 1
ALL DESIGNS, GRAPHICS AND DATA ON THIS SET OF DRAWINGS ARE THE INTELLECTUAL PROPERTY OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY AND HAVE BEEN CREATED AND DEVELOPED FOR THIS SPECIFIC PROJECT. USE OF ALL INTELLECTUAL PROPERTY BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE IS UNAUTHORIZED WITHOUT THE WRITTEN PERMISSION OF BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE PROJECT SITE, AND SHALL NOTIFY BLUE RIDGE ARCHITECTS PC, A BLUELINE COMPANY OF ANY DISCREPANCIES FROM THE DIMENSIONS AND CONDITIONS SHOWN IN THIS SET OF DRAWINGS. IF DISCREPANCIES ARE FOUND BETWEEN ANY ELECTRONIC FILES AND THE SEALED ORIGINAL, THE SEALED ORIGINAL SHALL GOVERN.
COPYRIGHT: 2019
PROJ NO:
E n g in e e ri n g
S o lu ti o n s S tr u c tu ra l E n g in e e rs
H a rr is o n b u rg
-4
-8
C h a rl o tt e s v ill e
-2
-8
R ic h m o n d
-4
-3
6/16/2022 1:41:02 PM
L
A U
R E
L H
IL
L R
D
V E
R O
N A
V
A
A U
G U
S T
A C
O U
N T
Y S
E R
V
IC
E A
U T
H O
R
IT
Y
S-001
GENERAL NOTES
0720-443
General Notes
1. All structural work shall be coordinated with architectural and mechanical drawings and shall conform to the project specifications, including the 2018 IBC and 2018 IEBC, as modified by the Virginia Uniform Statewide Building Code (VUSBC 2018).
2. The foundation design shown in these drawings is preliminary and for pricing purposes only. The design should be reassessed based on the actual column layout and building reactions by the Pre Engineered Metal Building supplier
3. During the erection of the building, the contractor shall be responsible for the temporary bracing to withstand all loads to which the structure may be subjected, including lateral loads, stockpiles of material and equipment. Such bracing shall be left in place as long as required for safety and until all framing including roof deck is in place.
4. The contract drawings and specifications are complimentary. These notes highlight rather than replace the specifications contained in the project manual. Where discrepancies exist the more stringent as determined by the Structural Engineer of Record (SER) shall govern.
5. The term "provide", where used in these drawings, is to be interpeted as a combination of both "furnish" and "install".
6. Use structural and architectural drawings in close coordination. Direct any dimensional discrepancy or omission to the architect for resolution prior to commencement of construction.
7. Coordinate configuration and location of equipment supports and openings with approved mechanical or other approved shop drawings.
8. Where structural members pass through or above non-load-bearing partitions, provide clearances to permit the structure to deflect without loading the partitions. Where specific clearances are not indicated, provide not less than 1" around the members. Pack the clearance spaces with safing, mineral wool, fiberglass, or specific UL rated or listed assemblies indicated.
9. Where standards are referenced herein, it shall be assumed the edition is the current referenced standard by the governing jurisdiction.
03300 Cast in Place Concrete
03300.1 General
1.1 All concrete work shall conform to the ACI following governing standards.
a. American Concrete Institute (ACI) "Code Requirements for Structural Concrete" (ACI 318), latest edition per governing building code.
b. ACI "Manual of Concrete Practice", latest edition per governing building code.
c. Concrete Steel Reinforcing Institute (CRSI) "Manual of Standards Practice", latest edition per governing building code.
1.2
a. Concrete Mix Designs - Concrete mix designs shall be prepared in accordance with the most recent edition of ACI 318 and with the information indicated in the mix design table. Submittal shall include which concrete mixes are to be used for mix ID designated below.
03300.2 Products
2.1 Refer to specifications for allowable concrete materials including cement, aggregate, water and admixtures.
2.2 Reinforcing steel shall be deformed bars conforming to ASTM A615, Grade 60 or A775 epoxy coated when called out on plan. Reinforcing steel shall be detailed according to the ACI "Details and Detailing of Reinforcement", (ACI 315), latest edition per governing building code.
2.3 Welded wire fabric (WWF) shall conform to ASTM A1064, with a minimum yield strength of 65,000 PSI.
2.4 All grout shall be non-shrink with a minimum compressive strength of 5,000 PSI.
2.5 All concrete exposed to weather with the potential to freeze and thaw should have air entrainment of 4% to 6%
03300.3 Execution
3.1 Provide clearance from face of concrete to reinforcement as follows unless noted otherwise:
a. Slabs: 3/4"
b. Beams and columns: 1-1/2"
c. Footings: 3"
d. Exterior walls: 2" for #6 or larger, 1-1/2" for #5 or smaller
e. Interior walls: 3/4"
3.2 Clean and roughen to 1/4" amplitude all existing concrete surfaces to receive new concrete prior to placement.
3.3 Welded wire fabric reinforcement in composite construction shall have tension splices and be anchored at discontinuous edges.
3.4 Reinforcing dowels, waterstops and other embed items shall be installed and secured prior to concrete. No wet setting of anchors is permitted.
3.5 Coordinate size and location of all openings and pipe sleeves with all other disciplines drawings. Minimum concrete between sleeves shall be 6".
3.6 Aluminum shall not be placed, touching or embedded in concrete.
Member f'c(psi) Density
Durability Exposure Classes
F S P C
Footings 3000 Normal F2 S0 P0 C1
Foundation Piers 4000 Normal F2 S0 P1 C1
Slabs-on-grade (interior) 4000 Normal F1 S0 P0 C1
Exterior Slabs 4000 Normal F2 S0 P1 C1
05400 Cold Formed Metal Framing
05400.1 General
1.1 All cold formed metal framing work shall comply with the AISI "Specification for the Design of Cold Formed Steel Structural Members", latest edition as well as ANSI A42-4 and the metal lath association "Specifications for Metal Lathing and Furring".
1.2 Contractor is responsible for providing all temporary bracing and shoring as required until erection is completed and all attached adjecent framing is complete.
05400.2 Products
2.1 All load bearing studs, joists and accessories shall be made of the minimum type, size, gauge and spacing shown on drawings.
2.2 All galvanized studs and/ or joists, 10, 12, 14 and 16 gage, shall be formed from steel that corresponds to the requirements of ASTM A446, Grade D, with a minimum yield of 50,00 psi.
2.3 All galvanized 18 and 20 gage studs and/ or joists, and all galvanized track, bridging and accessories shall be formed from steel that corresponds to the requirements of ASTM A446, grade A, with a minimum yield 33,000 psi.
2.4 All studs, joists/ rafters and accessories 16 gauge or heavier shall be formed from steel that conforms to ASTM A653 with minimum yield strength of 50 ksi.
2.5 All studs, joists/ rafters and accessories 18 gauge or lighter shall be formed from steel that conforms to ASTM A653 with minimum yield strength of 33 ksi.
2.6 All studs, joists and accessories shall be primed with rust - inhibitive paint meeting the performance requirerments of TT-P-636C, or shall be formed steel having a C-60 galvanized coating.
2.7 All studs, joist/ rafters and accessories to be of the type, size, thickness and spacing as shown on the plans, and shall conform to ASTM C995.
05400.3 Execution
3.1 All plywood applied to metal joists shall be screwed and glued to the joists. The adhesive shall be an APA-approved elastomeric adhesive.
3.2 Install metal framing in accordance with manufacturer's written instructions and recommendations, unless otherwise indicated. All materials shall be galvanized.
3.3 Framing components may be pre-assembled into panels prior to erecting. Prefabricated panels shall be square with components attached in a manner as to prevent cracking.
3.4 Axially loaded studs shall be installed in a manner which will assure the ends of the studs are positioned against the inside track web, prior to stud and track attachment.
3.5 Studs shall be plumbed, aligned and securely attached to the flanges or webs of both upper and lower tracks.
3.6 Wall stud bridging shall be attached in a manner to prevent stud rotation. Bridging rows shall be spaced according to the following schedule.
a. Walls up to 10'-0" height: one row at mid-height.
b. Walls exceeding 10'-0" height: bridging rows spaced not to exceed 5'-0" on center.
3.7 Joists shall be located directly over bearing studs or load distribution member to be provided at the top track.
3.8 Materials to be stored flat and in such a way as to avoid damage. Damaged material shall be removed from the jobsite.
3.9 Fastening:
a. Anchorage of track shall be with methods designed for that specific application. Size, type, spacing and penetration of fasteners shall be as shown on plans.
b. Welds shall conform to the requirements of AWS E1.3, AWS D1.3 and AISI manual. Welds may be butt, fillet, spot or groove type, the appropriateness of which shall be determined by design calculations. All welds are to be touched up with zinc rich paint.
c. Steel drill screws shall be of the minimum diameter indicated by the design of that particular attachment detail. Penetration through joined materials shall be a minimum of 3 exposed threads.
3.10 Provide bracing on all cold formed metal framing at a maximum spacing of 48" or per manufacturer's requirements. Bracing to be installed prior to placing any load on the studs.
Foundations
1. Design based on soil bearing capacity of 2000 psf.
2. Establish exterior footing elevations such that the bottoms of footings are not less than 30" below final finished grades.
Geotechnical engineer may require additional depth if unsuitable soils are encountered.
3. Establish tops of footings on masonry coursing.
4. Provide construction site drainage to prevent surface runoff from entering footing excavations.
5. Consolidate granular fill below slabs on grade with vibrating compactors according to the directions of the geotechnical engineer, but not less than 95% of maximum density in accordance with ASTM D698 or D1557.
6. The contractor shall protect the footing and slabs from damage from frost heave during construction until the final design structure is complete.
7. Steps in wall footings shall have a minimum spacing of double the change in elevation.
8. Backfill against walls spanning vertically between floors shall not be placed until both floors are in place and concrete has reached 75% of its 28-day strength.
9. At non-retaining walls below grade, backfill against both sides of wall simultaneously so that grade difference is no more than 1'-0" at any time.
Design Load and Parameter Table
Design Loads
Building Risk Category II
Live Loads
50 psf Second Floor Office Space
125 psf Shop Mezzanine (Light Storage)
20 psf Area above Ceiling
Snow
Pg 43 Ground Snow Load
Pf 30 Flat Roof Snow Load
Ce B Snow Exposure Factor
Is 1.0 Snow Load Importance Factor
Wind
Basic Wind Speed 115mph
10-Year MRI 76mph
25-Year MRI 84mph
50-Year MRI 90mph
100-Year MRI 96mph
Iw 1.0 Wind Importance Factor
Exposure B Urban Centers
Cg +/- 0.18 Internal Pressure Coefficient
Seismic Design Data
Is 1.0 Seismic Importance Factor
Ss 0.162 Short Second Period Mapped Spectral Response Acceleration
S1 0.065 1-Second Period Mapped Spectral Responce Acceleration
Site Class D Assumed
Sd-s 0.173 Short Period Response Acceleration
Sd-1 0.103 1-Second Period Responce Acceleration
Seismic Design Category B
04220 Masonry Work
04110.1 General
1.1 Governing Standards:
a. American Society for Testing and Materials
1. ASTM C141/ C141M - Standard Specification for Hydrated Hydraulic Lime for Structural Purposes.
2. ASTM C144 - Standard Specification - Aggregate for Masonry Mortar.
3. ASTM C404 - Standard Specification for Aggregates for Masonry Grout.
4. ASTM C476 - Standard Specification for Grout for Masonry.
5. ASTM C1019 - Standard Specification for Method of Sampling and Testing Grout.
b. National Concrete Masonry Association Specifications, latest edition.
c. ACI 530 - Building Code Requirements for Masonry Structures, latest edition.
1.2 Submittals - Submit data on design mix, indicate proportion or property method used, and required enviromental conditions.
04110.2 Products
2.1 Concrete Block
a. ASTM C90, Grade N1
b. Block unit strength shall be 2000 psi minimum, unless otherwise noted on plan.
c. All concrete block dimensions indicated on structural plans are nominal dimensions.
2.2 Clay Masonry
a. Units shall be in accordance with ASTM C216 for facing brick, see arch for weathering and appearance requirements.
1. In absence of Architectural specification, units shall be SW type FBS. Color to be selectd by owner.
b. Clay Masonry Unit strength shall be 1500psi, unless noted otherwise on plan.
c. All clay masonry dimensions indicated on structural plans are nominal dimensions. See arch for dimensions not shown.
2.3 Mortar
a. Mortar shall be ASTM C270, Type N
1. Repair mortar shall in addition be rapid set, example is Simpson FX-263 repair mortar.
2.4 Grout
Grout filling for cells shall be ASTM C476 with minimum compressive strength of 2500 psi but not less than the compressive strength of the masonry assembly, f'm. Where grout cells do not exceed 4" in diameter, fine grout shall be used.
2.5 Sealant
a. Elastomeric sealants used for expansions should conform to ASTM C920 Class 50, Grade NS, Use M.
1. Example is SIKA SIKASIL WS-295.
2.6 Ties
a. Wall (unit) ties
1. "Box ties" and "Z" ties shall be fabricated from cold-drawn steel wire conforming to ASTM A82 and wire shall be W1.7 or 9 gauge, unless otherwise noted.
i. When specified as stainless steel, ties shall conform to ASTM A580.
2. Corrugated sheet steel ties conform to ASTM A1008 and sheet shall be 16 gauge, unless otherwise noted.
i. When specified as stainless steel, ties shall conform to ASTM A240.
b. Helical ties
1. Where helical ties are specified, ties shall be type 304 stainless steel.
i. Example is Simpson Heli-Tie.
2.7 Loose Steel Lintels
a. Steel shall be constructed in accordance with steel notes
b. Lintels shall be in accordance with table below:
04110.3 Execution
3.1 Typical masonry construction
a. Unless otherwise noted on plans and/ or elevations, all masonry walls shall be reinforced with #4 @48" on center vertically. Grout all reinforced cells solid. Provide dowels to match vertical reinforcing at foundation.
b. Install standard weight ladder joint reinforcement at 16" on center (spaced vertically).
c. All concrete block below grade shall be filled solid with grout.
d. Concrete block below beam or truss bearing points shall be filled solid for a minimum of two courses in depth and a minimum of 32" in width, unless otherwise noted.
e. Provide a #4 bond beam at the top of all masonry walls.
f. Where brick veneer is tied to CMU walls, provide rectangular brick ties spaced at 16" on center vertically and 32" on center horizontally. Reinforce ties with ladder type reinforcement assembly. Provide 1" cavity between brick and CMU.
05120 Structural Steel
05120.1 General
1.1 Governing Standards:
a. AISC 360 "Specification for the Design, Fabrication and Erection of Structural Steel for Buildings", latest edition.
b. AISC 303 "Code of Standard Practice for Steel Buildings and Bridges", latest edition.
c. The American Welding Society (AWS D1.1) "Code for Welding in Building Construction", latest edition.
1.2 Shop and erection drawings shall be submitted to the structural engineer for review and approval. No fabrication of steel shall commence without approved shop drawings. This includes but is not limited to steel framed stairs and railing.
a. Shop drawings shall indicate verification of field conditions. Engineer of record is not responsible for discrepancies between drawings and field conditions.
05120.2 Products
2.1 Connections of beams/ girders are to be designed as follows:
a. Standard beam to beam/ girder: A325 or A490 bearing type bolts
b. Bolts shall be 3/4" diameter minimum with hardened washers
c. Steel connection shall be standard AISC framed beam connection and shall be designed by a licensed engineer working for the fabricator, who shall provide calculations utilizing ASD or LRFD loads procedures.
d. For non-composite members, provide connections based on reaction as determined from AISC uniform load table (unless otherwise noted on plans).
e. For composite members, provide connections based on 1.5 x reaction from AISC uniform load table (unless otherwise noted on plans).
f. Reinforcing is to be provided at connections where cuts reduce the shear or moment capacity below that required to sustain the reaction, or if the cut reduces the nominal moment capacity of the member by more than 49%
g. Connections shall be designed for shear and eccentricity, considering that the connection is an extension of the beam and girders.
2.2 Structural steel shall conform to the following ASTM specifications:
a. Structural steel shapes shall conform to preferred material specification outlined in AISC 360.
b. Anchor bolts: ASTM F1554, Grade 36
2.3 Stainless Steel - Structural steel noted to be stainless steel shall be ASTM A276 stainless steel Grade 304
a. Bolts shall conform to ASTM F593 Alloy 304
b. Nuts shall conform to ASTM F94 Alloy 304
c. Welding electrodes for ASTM A276-97 stainless steel, Grade 304, shall conform to AWS A5.4 for shielded metal arc welding, electrode class E304; or AWS A5.9 for gas metal arc welding, electrode Class ER304, Ft=70 KSI.
2.4 Finishing
a. Steel members exposed to the exterior shall be hot dip galvanized. Hot dip galvanizing shall conform to ASTM A123, repair scratches or abraded galvanized surface with zinc rich paint.
b. Interior steel members shall be coated with a zinc rich rust preventative primer.
c. Steel members that are spray fireproofed or coated with intumescent paint shall be coated with a compatibile primer respectively.
05120.3 Execution
3.1 Minimum weld size is 3/16" fillet unless noted otherwise.
3.2 All beams except cantilever beams shall be fabricated and installed with natural camber up.
Cantilever beams shall be fabricated an installed so that natural camber raises cantilever end.
3.3 Welding shall be performed by certified licensed, AWS-qualified welders. Electrodes shall be AWS 5.1, class E70XX (use low hydrogen electrodes for A572, Grade 50 steel).
3.4 Field cutting or burning of steel is prohibited except with the express written approval of the Structural Engineer of Record.
3.5 Splice members only where indicated.
3.6 Wet setting of anchor bolts is not permitted.
3.7 Touch up welds and scratches on galvanized members with cold galvanizing compound such as ZRC.
MATERIAL INSPECTION ACTIVITY
FREQUENCY:
CONTINUOUS
PERIODIC
NOT
APPLICABLE
IBC REFERENCE
INSPECTION/ TEST BY
SPECIAL
INSPECTIONS
ENGINEER OF
RECORD
(SIER)
A/E OF
RECORD
CONTRACTOR/
SUPPLIER
FOUNDATIONS
Soil Classify & Test Existing Soils & Fill Materials
Specs,1705.6 X
Soil Compaction Of Fill Materials
Specs,1705.6 X
Soil Bearing At Bottom Of Fotting Excavations
Specs,1705.6 X
Piles Driving Records, Tip & Cutoff Elevations
1705.7, 1705.9
Piles Load Test 1705.7
Caissons Drilling, Size, Bearing Conditions, Materials
1705.8, 1705.3
CONCRETE
CONSTRUCTION
Concrete Ready-Mix Plant Quality Control
Specs,1704.2.5 X
Concrete Mix Design Tests And Certificates
Specs,1705.3 X
Reinf. Steel Shop Drawings Of Reinforcing Steel
Specs
Reinf. Steel Placement Of Reinforcing Steel
1705.3 X
Reinf. Steel Welding 1705.2.2 X
Formwork Shape, Location, Dimensions
1705.3 X X
Formwork Removal And Reshoring 1705.3 X
Concrete Test Cylinders & Strength Test
1705.3, 1910.10 X
Concrete Mix Proportions & Mix On Delivery Tickets
1705.3
Concrete Slump Test 1705.3 X
Concrete Placement Procedures 1705.3 X
Concrete Curing Temperatures & Techniques
1705.3 X
Post Tensioning Field Stressing Techniques And Logs
Specs
Post Tensioning Shop Drawings Specs
Precast Quality Control Of Manufacturer
1704.2.5
Precast Shop Drawings Of Precast
Specs
Precast Erection Of Precast 1705.3
Precast Inspection Of Connection 1705.3
Anchors Cast In Concrete
Anchors Cast In Concrete Specs,1705.2.1, MASONRY
CONSTRUCTIONS
Qality Assurance
Indicate Quality Assurance Level C
ACI 530, 1.19.1, 2,
Clay Masonry Certificates, Test & Technical Data
ACI 530, Table 1.19.1
Concrete Masonry
Certificates, Test & Technical Data
ACI 530, Table 1.19.1
X X
Reinf. Steel Shop Drawings Specs X X
Reinf. Steel Size, Grade, Type, Location, Spacing Of Reinf. Steel
ACI 530, Table 1.19.1
X X
Anchors Manufacturer's Data ACI 530, Table 1.19.1
X
Accessories Manufacturer's Data Specs X
Mortar & Grout Mix Design And Data Specs X
Mortar & Grout Field Samples ACI 530, Table 1.19.1
X
Risk Cat. IV A/E Shall edit list as required by ACI 530
Tables…
This is the start of the file's text. The full file is on GovTribe.