This is an Asbestos Inspection Report for Building FC500 at MCB Camp Lejeune, dated January 20, 2022. The report documents an extensive survey of potential asbestos-containing materials (ACM) throughout the administrative battalion headquarters building constructed in 1989. Multiple samples were collected from various building elements including ceiling tiles, floor tiles, vinyl base, duct sealants, drywall, carpet adhesive, and exterior caulking on the same date (5/11/2004). Notably, while numerous materials were sampled, all samples returned 0% for chrysotile, amosite, and other asbestos percentages, resulting in a Hazard Ranking of 0/Blue with no asbestos identified. The report provides detailed guidance on handling potential ACM, emphasizing that intact and undisturbed materials do not constitute a health hazard, and instructs occupants to avoid disturbing any materials and to report any damage to the Asbestos Program Manager at (910) 451-5837.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT of:

Building # FC500

MCB CAMP LEJEUNE

Thursday, January 20, 2022

Print Date

Thursday, January 20, 2022 Page 1 of 5Print Date:

INSPECTION SUMMARY

BLDG #:

OCCUPANT:

YEAR BUILT:

BUILDING COMMENTS:

FC500

BATTALION HQ- ADMINISTRATIVE

HAZARD RANKING- 0/BLUE; NO ASBESTOS IDENTIFIED(AH MAY07).

RI MAY 07

NO CHANGES FROM PREVIOUS INSPECTION. NO FURTHER ACTION REQUIRED.

ASBESTOS MANAGER: 910-451-5837

Friable ACM(s) identified

Non-friable ACM(s) identified

Tested Non ACM or REMOVED Materials

DESCRIPTION LOCATION Date

NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.

DESCRIPTION LOCATION Date Quantity

DESCRIPTION LOCATION Date Quantity

No friable ACM records found in database

No non friable ACM records found in database

NOTIFICATION OF ACM IN BUILDING

CARPET ADHESIVE OFFICE AREAS 5/11/2004

BROWN VINYL BASE AND ADHESIVE, 4" PATCHES ASSOCIATED WITH [HA04] 5/11/2004

12" WHITE w/ GRAY FLOOR TILE AND

ADHESIVE

PATCH AREAS THROUGHOUT 5/11/2004

BEIGE VINYL BASE AND ADHESIVE OFFICE AREAS ASSOCIATED WITH

[HA04]

5/11/2004

DUCT SEALANT, BROWN OVERHEAD DUCT SYSTEMS 5/11/2004

DRYWALL AND JOINT MATERIAL INTERIOR PARTITION WALLS 5/11/2004

DUCT SEALANT, BROWN DUCTS OVERHEAD 5/11/2004

FIBERGLASS INSULATION SEALANT MECH ROOM AND OVERHEAD PIPING 5/11/2004

12" BLUE FLOOR TILE AND ADHESIVE CORRIDORS 5/11/2004

12" BEIGE FLOOR TILE AND ADHESIVE OFFICES 5/11/2004

4" VINYL BASE AND ADHESIVE CORRIDORS WITH BLUE TILE [HA03] 5/11/2004

Thursday, January 20, 2022 Page 2 of 5Print Date:

ACM only presents a health hazard when asbestos fibers are airborne and inhaled.

Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.

HEALTH ASPECTS:

Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.

CONDITIONS TO AVOID:

Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos

Program Manager.

REPORTS OF DAMAGE:

Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:

ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:

The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.

RECORDKEEPING:

CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837

2'x2' CEILING TILE, THROUGHOUT 5/11/2004

2'x2' CEILING TILE, THROUGHOUT 5/11/2004

2'x2' CEILING TILE, REPLACEMENT TILE THROUGHOUT 5/11/2004

VINYL THRESHOLD MATERIAL CARPET/TILE/CONCRETE TRANSITIONS 5/11/2004

EXTERIOR CAULKING, WINDOWS AND DOORS 5/11/2004

FIBERGLASS INSULATION SEALANT MECHANICAL ROOM 5/11/2004

Thursday, January 20, 2022 Page 3 of 5Print Date:

SAMPLES COLLECTED

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

FC500-01-01 5/11/200401 NW CORRIDOR 0 0 02'x2' CEILING TILE, TYPE I

FC500-01-02 5/11/200401 CENTER CORRIDOR 0 0 02'x2' CEILING TILE, TYPE I

FC500-01-03 5/11/200401 SI ADMINISTRATION, EAST 0 0 02'x2' CEILING TILE, TYPE I

FC500-02-01 5/11/200402 NW CORRIDOR 0 0 02'x2' CEILING TILE, TYPE II

FC500-02-02 5/11/200402 CENTER CORRIDOR 0 0 02'x2' CEILING TILE, TYPE II

FC500-03-01 5/11/200403 NW CORRIDOR 0 0 012" BLUE FLOOR TILE

AND ADHESIVE

FC500-04-01 5/11/200404 NW DUTY ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

FC500-05-01 5/11/200405 NW CORRIDOR 0 0 04" VINYL BASE AND

ADHESIVE

BLUE

FC500-06-01 5/11/200406 NW OFFICE/ DUTY ROOM 0 0 0BEIGE VINYL BASE AND

ADHESIVE

FC500-07-01 5/11/200407 NW CORRIDOR 0 0 0DUCT SEALANT, BROWN (TAN)

FC500-07-02 5/11/200407 CENTER CORRIDOR 0 0 0DUCT SEALANT, BROWN (TAN)

FC500-08-01 5/11/200408 NW CORRIDOR 0 0 0DRYWALL AND JOINT

MATERIAL

FC500-08-02 5/11/200408 NEW WALL, BLDG. CENTER 0 0 0DRYWALL AND JOINT

MATERIAL

FC500-08-03 5/11/200408 SI ADMIN OFFICE, COLLUMN 0 0 0DRYWALL AND JOINT

MATERIAL

FC500-09-01 5/11/200409 NW OFFICE 0 0 0CARPET ADHESIVE YELLOW

FC500-10-01 5/11/200410 NW OFFICE 0 0 0BROWN VINYL BASE

AND ADHESIVE, 4"

FC500-11-01 5/11/200411 NW OFFICE 0 0 012" WHITE w/ GRAY

FLOOR TILE AND

ADHESIVE

FC500-12-01 5/11/200412 NW CORRIDOR 0 0 02'x2' CEILING TILE, TYPE III

FC500-13-01 5/11/200413 CENTER CORRIDOR 0 0 0DUCT SEALANT, BROWN

FC500-13-02 5/11/200413 OVERHEAD 0 0 0DUCT SEALANT, BROWN

Thursday, January 20, 2022 Page 4 of 5Print Date:

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

FC500-14-01 5/11/200414 OVERHEAD 0 0 0FIBERGLASS

INSULATION SEALANT

WHITE

FC500-14-02 5/11/200414 MECH ROOM 0 0 0FIBERGLASS

INSULATION SEALANT

WHITE

FC500-15-01 5/11/200415 SOUTH CORRIDOR 0 0 0VINYL THRESHOLD

MATERIAL

BROWN

FC500-16-01 5/11/200416 DOOR, SE ENTRY 0 0 0EXTERIOR CAULKING, GRAY

FC500-16-02 5/11/200416 WINDOW, EAST SIDE 0 0 0EXTERIOR CAULKING, GRAY

FC500-17-01 5/11/200417 MECH ROOM 0 0 0FIBERGLASS

INSULATION SEALANT

GRAY

FC500-17-02 5/11/200417 MECH ROOM 0 0 0FIBERGLASS

INSULATION SEALANT

GRAY

Thursday, January 20, 2022 Page 5 of 5Print Date: