BUILDING_26ABCD_EXTERIOR_REPAINT_SET_OF_SPECS_AND_DRAWINGS.pdf
PDF 16 MB Posted
- Solicitation number
- 2026-068
- Issued by
- Los Angeles County, California
About this file
This document is a set of specifications and drawings for Mt. San Antonio College's Building 26ABCD Exterior Repaint Project located in Walnut, California. The project scope encompasses complete exterior surface preparation and painting of the entire building complex, including four connected buildings (Buildings A, B, C, and D). Work activities include surface preparation, surface repairs, patching, caulking, sealant application, and paint application on exterior surfaces and doors. The drawings provided show the first and third floor plans of Building 26ABCD with dimensions, layout details, and keynotes indicating specific work requirements. The project requires contractors to coordinate with District representatives regarding removal or modification of existing elements, exercise care to prevent damage to elements intended to remain, verify all dimensions and conditions at the site, and repair and repaint wall surfaces following removal of wall-mounted equipment and fixtures. Contractors must protect in place all signage, fire extinguishers, pipes, connections, rails, lights, fire devices, and other equipment during construction.
The solicitation is in the prequalification phase only, and contractors must submit a complete prequalification application with all required supporting documentation to be eligible for the subsequent bidding phase. Only firms receiving a Prequalification Approval Letter from the District will be invited to submit a bid when the project is formally released for bidding. Previous prequalification approvals for other Mt. San Antonio College projects do not apply to this solicitation. The project specifications, construction agreement, general conditions, and other contract documents are provided for informational purposes and will govern the bidding phase. Contractors who fail to receive prequalification approval will not be permitted to submit a bid for this project.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cir--', C 91----�-+-- -------- -- N
=-11-1-1-+1-lup
............. "'"_J
2 6 7 8 15
I I I I I I
I I I I I I I I 244'-o"I I I I I I I I I I 11 I I I I I I I I I I I I I I I I I I I I
T +.( l 2 BUILDII GA 3 4
OP t'
Lf1 2 3
4 f.J LJ \J n
1 2 3 4 I
5 u ,, 7 :e
�------l---------- • • • • • •
(E
T u f----- -- - -----1+
- -----lC- - - --- - - --tt- -1 - -• + � 1----- - -'I� - -- - -- - --tt--1 - -
Gr- - -----l--- - - - - ---++--f-------------1+•
@r-�-- ----- ---l-l-----1- --
� - -----l-- ---- ----l-l--· r==�
0)--- '' -- - -- - --tt--1 - -
N
UP
I\.
1Z1 ,x\ u TRASH CHUTE r----
1 2
COVERED WAL'fJNAY
_ 5 6 1J
7 B I
DN .__ ___ _.I DNI------'
5 X 6 17 8 1 nl/�����===;===lrl;-;=;='r�;::::;::?-'
DN ----)
] BUILDING B -
\_ LJ
LJ
""""=======l�I f1 ==;r===;aaa!.!
n
__r __r j (1'0, 3 4 )'
I � ...___. DN H
i(s 6'7 aI I - - - -
DNl------'·1 DNI------> l 1 � . .f L.
COVERED WAJ..IWIAY
1 2 3 4J u
DN-
n Ill nlJ If"'_ n
D t==:! I I 1 , I 7 B
86'-4"
B ILDING C
I
,� ..... G
·�· s )\..:_,, KEYNOTES
0 SURFACE PREPARATION AS INDICATED ON SHEET GI .2, TYPICAL.
0 SURFACE REPAIR AS INDICATED ON SHEET GI .2, TYPICAL.
0 PROVIDE CAULKING AS INDICATED ON SHEET GI .2, TYPICAL.
0 PROVIDE SEALANTS AS INDICATED ON SHEET GI .2, TYPICAL.
® PATCHING AS INDICATED ON SHEET
G1.2, TYPICAL.
CD APPLICATION OF PAINT AS INDICATED ON
WORK SHEET GI .2, TYPICAL.
0 PAINT EXTERIOR DOOR AND DOOR FRAME, TYPICAL.
CD PROTECT IN PLACE All SIGNAGE, FIRE EXTENGUSHER, PIPES, CONNECTIONS, RAILS, LIGHTS, FIRE DEVICES, AND ANY OTHER EQUIPMENT.
TYPICAL.
LEGEND
EXISTING NON-RATED PARTITION
EXISTING ELEMENT TO BE REMOVED OR MODIFIED
EXISTING ELEMENT TO REMAIN
DEMOLITION KEY NOTE
REMODEL KEY NOTE
D AREA NOT IN CONTRACT SCOPE (N.I.C.)
GENERAL NOTES
DEMOLITION WORK:
1. CONTRACTOR SHALL COORDINATE WITH DISTRICT'S
REPRESENTATIVES IF & WHEN EXISTING ELEMENTS SUCH AS
WALLS, CEILINGS, DOORS, FIXTURES, ETC. INDICATED TO BE REMOVED
SHALL HAVE CONFLICT &/OR IMPACT TO CONSTRUCTION
PROCEDURES.
2 CONTRACTOR TO EXERCISE EXTRA CARE TO ENSURE EXISTING
ELEMENTS INDICATED TO REMAIN Will NOT BE DAMAGED DURING DEMOLITION. COl'ITRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR
OF THE DAMAGED ELEMENT & RESTORE TO ITS ORIGINAL
CONDITION AT OWN EXPENSE.
REMODEL WORK:
1. VERIFY ALL DIMENSIONS & CONDITIONS AT THE SITE. REPORT
CONDITIONS DISCOVERED THAT ARE NOT RECOGNIZED BY THESE
DOCUMEITTS TO THE DESIGN PROFESSIONAL IN GENERAL
RESPONSIBLE CHIARGE.
2. All DIMENSIONS TO F.O.F., U.N.O.
3. DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED.
4. REFER TO SPECIFICATION FOR FINISHES.
5. USE DRYWALL SCREW ANCHORS FOR ATTACHMENT OF ALL WALL
MOUNTED ACCESSORIES, EQUIPMENT, & FURNITURE ITEMS LESS
THAN 20 LBS. WITHOUT BACKING.
6. REPAIR (E) FINISH, PATCH I PAINT WALL TYPICALL Y FOR EVERY
REMOVAL OF WALL MOUNTED EQUIPMENT, ARTWORK, SIGNAGE,
WALL PROTECTION.
BUILDING 26ABCD 1 ST FLOOR PLAN
N.T.S
MT.SAC
Mt. San Antonio College
1100 NORT H GRAND AVENUE
WALNU T, CA 91789-139 9
www.mtsac.edu 909.274.7500
I a,C: a, en
:z w c::: (.)
.,:c..� w□ 0 ai z c:::
(.) en w drawing data:
DATE: 0512512026
SHEET SIZE: 24 X 36
FILENAME: .dwg
DRAWN BY: QC
CHECKED BY: QC
COPYRIGHT:
MT. SAN ANTONIO COLLEGE
key plan:
26,\ f 2SB 26Cl project title:
BUILDING
26ABCD
EXTERIOR
REPAINT
PROJECT
sheet name:
BUILDING
26ABCD
1ST FLOOR
PLAN
sheet number.
A 1.0
SHEET # OF #
N co
,_____8
I f 244'-0'
COVERED WAL'f<!NAY
�==:::i/\;====lf't:::;-/'Y''t:::.-=:;;::::::::,=s1
D
1 2
3 4
5 6 7 8 p
STAIR#1
.::-- JY
1 2 3:.ii
.. \. 5 6 7 8 u u
BUii DING A
REDWAL'rf:NAY f
I 1 2
I 3 4
5 6
------------------------- �·�. + -r--=-�:-:
u
J lA._
UP
"'"'-IY
g
• • 0 ••••• ·1 0 • � -- � -·�_,._ - -- . • • • • • • • • • • • • • • • • • • • • • • n "
( 1 I 2 u u -,_,-
3 4 ) l5X6 7 �)
COVERED WAL�AY
1 4 l
>< COVERED WAl�AY I 5 8 ) - -u u u
_j'"
O'"
II� l�l'!l�I y--I -- ,-
• ----r., JDF
-�!� I ml ----� �
STAIR#5
U7 c:1
LANDING BELOW UP
DN
I
C:I .n_J vv,;=--=±::::a� u
: \l
I!! y ) 11X ) -
I
1 2
-t' 5 (I'...
7 8 -
I
1 r ) 3 ) \ r
7 l I \._
I w � w
C<:NEPHJ WA1JeyAY I 1 2 3 4 r< 5 6 7 8
- I\:
IX I
'---111"'=�
I UILDING A
LJ
UP
STAIR#2
Yl
1 2 3 4 ) CO'/
5 6 7 8 )
I
{ 1 2 3 4
I 5 6 7 8
BUILbl�GsR/ X
I 1 2 3 4
I 5 6 7 8
1 2 3 4
-f'k 5 6 7 8 r, 1 1 n. ,,... n.
,Yo v= ffl
IL ..,, 8
IY1 -
� COVERED I 1 2
WAL�AY I 5 6 7 X a _-
I I
I I
I I
I
86'-4"
ELEVATOR#1
/ROOF_/
ATTIC
SPACE
/ROOF_/
OPENTOBELOW
lUILDINGC
------- ----+----I co co
--- M
- --- --- - -- -+----I
- Q
KEYNOTES
0 SURFACE PREPARATION AS INDICATED ON
WORK SHEET Gl.2, TYPICAL.
0 SURFACE REPAIR AS INDICATED ON
SHEET GI .2, TYPICAL
0 PROVIDE CAULKING AS INDICATED ON
SHEET GI .2, TYPICAL
0 PROVIDE SEALANTS AS INDICATED ON
SHEET GI .2, TYPICAL
® PATCHING AS INDICATED ON SCOPE OF WORK SHEET
G1.2, TYPICAL
CD APPLICATION
OF PAINT AS
INDICATED ON SSHEET GI .2, TYPICAL.
0 PAINT EXTERIOR DOOR AND DOOR FRAME, TYPICAL.
CD PROTECT IN PLACE All SIGNAGE, FIRE EXTENGUSHER, PIPES, CONNECTIONS, RAILS, LIGHTS, FIRE DEVICES, AND ANY OTHER EQUIPMENT, TYPICAL.
D
LEGEND
EXISTING NON-RATED PARTITION
EXISTING ELEMENT TO BE REMOVED OR MODIFIED
EXISTING ELEMENT TO REMAIN
DEMOLITION KEY NOTE
REMODEL KEY NOTE
AREA NOT IN CONTRACT SCOPE (N.I.C.)
GENERAL NOTES
DEMOLITION WORK:
I. CONTRACTOR SHALL COORDINATE WITH DISTRICT'S
REPRESENTATIVES IF & WHEN EXISTING ELEMENTS SUCH AS
WALLS, CEILINGS, DOORS, FIXTURES, ETC. INDICATED TO BE REMOVED
SHALL HAVE CONFLICT &/OR IMPACT TO CONSTRUCTION
PROCEDURES.
2 CONTRACTOR TO EXERCISE EXTRA CARE TO ENSURE EXISTING
ELEMENTS INDICATED TO REMAIN Will NOT BE DAMAGED DURING DEMOLITION. COl'ITRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR
OF THE DAMAGED ELEMENT & RESTORE TO ITS ORIGINAL
CONDITION AT OWN EXPENSE.
REMODEL WORK:
I. VERIFY ALL DIMENSIONS & CONDITIONS AT THE SITE. REPORT
CONDITIONS DISCOVERED THAT ARE NOT RECOGNIZED BY THESE
DOCUMEITTS TO THE DESIGN PROFESSIONAL IN GENERAL
RESPONSIBLE CHIARGE.
2. All DIMENSIONS TO F.O F., U.N.O.
3. DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED.
4, REFER TO SPECIFICATION FOR FINISHES.
USE DRYWALL SCREW ANCHORS FOR ATTACHMENT OF ALL WALL
MOUNTED ACCESSORIES, EQUIPMENT, & FURNITURE ITEMS LESS
THAN 20 LBS. WITHOUT BACKING.
REPAIR (E) FINISH, PATCH I PAINT WALL TYPICALL Y FOR EVERY
REMOVAL OF WALL MOUNTED EQUIPMENT, ARTWORK, SIGNAGE,
WALL PROTECTION.
N
E9
BUILDING 26ABCD 2ND FLOOR PLAN
N.T.S
MT.SAC
Mt. San Antonio College
1100 NORT H GRAND AVENUE
WALNU T, CA 91789-139 9
www.mtsac.edu 909.274.7500
C:
·a;
I a, C: a, en
:z c:::
en
,ij c:::< ct.
cc
<D z
Ii:
c:::
en w
L-..J..._j_ _ _.
drawing data:
DATE: 0512512026
SHEET SIZE: 24 X 36
FILENAME: .dwg
DRAWN BY: QC
CHECKED BY: QC
COPYRIGHT:
MT. SAN ANTONIO COLLEGE
key plan:
I 2S,\ f 2SB 26C l
I 260 project title:
BUILDING
26ABCD
EXTERIOR
REPAINT
PROJECT
sheet name:
BUILDING
26ABCD
2ND FLOOR
PLAN
sheet number.
A 1.1
SHEET #OF#
N co
,_____8
I f 244'-0' l�-�-�---�---�---�---�---------------�-----��---�---��--�-�-�-�t l l � I
I I
- 11 2Y3]4l - - - - - 11 2 3 4 - I I � � ,....._ _,,,, ...._ - '>-,(';;.<'):..{'>-< I
I I 5 B y l ,�)
COVERED WALKWAY COVEREDWALKWAY
5 B r"
86'-4"
A.. 't::::==;::::I �A't:::.--==== r.===:::I - 7 8
I lA ,1:J "1 2 W b U � '°; IX ELEVAjOR#1
1 2
3 4
5 6
7 8
STAIR#1
�-�JY
I 1 2 3 �
BUI _DING A
Jr
I'\'
� l�l'!I� v--5 -- -
I ----'"" JDF
-�!v - I ml ----� :i I 6 7 8
COVERED WALKWAY
I .. '" 5 ..
L u u u-, 5 6
7 8 i:' � w � w u
BUil[ NG A
STAIR#2
F,;:;��4�\ F- Y11=:;;=µ 1 23 )\J I
COVERED WAl.'fflAY 5 6 7 8, I
- I ________ ' ______ J
STT
I
I
----------------------------------7�1
I 1 2
I 3 4
5 6
------------------------- �·�. + -r--=-�:-:...... ·'---�
• • 0 ••••• ·1 0 • � -- � --�_,._ - -- . • • • • • • • • • •• • • • • • • • • • • •
STAIR#S ·.� 1·" 4 .,
ON
m �J
J
1 2
3 4
5 6
7 8 • BUILDING B
ROOF
i I g m I n n .n..J I - (
I 1 I 2 3 4 l COVEREDWALKWAV
I LA - �t:=
..-.:::==�- ..,c::J 1:::::==;;;;::::=111
ON
-«ii� - '
00 00 l o :' 7 -
1 2
3 4
5 6
7 8
-, I '■ - ■ a ■ - -
"\ r
El �
TRASH CHUTE
X
8 -
--------. ------7
COVERED W/lJ..'fmAY
-.., - I1 2 3 } I 5 s 7 a I
'"'I 111 n.1• I ,-,. n.
STAIR#4
"- JY
I
M�, 3 4 l) .\__ \J vv I 1 2 ( � I I I
8 ) COVEREDWAl.�AY COVERE□WflJ.JfflAY I _ _ (5 7 _ _ _ _ _ _ _ is sv1Ya)_ _ u u u u u
- I
L ______________________________________________________________ J
I
I I
I I
I I
I
ROOF
ROOF
BU1tDING C
------- ----+----I co co
--- M
- -- -- -- - -- -+----I
- Q
KEYNOTES
0 SURFACE PREPARATION AS INDICATED ON
WORK SHEET Gl.2, TYPICAL.
0 SURFACE REPAIR AS INDICATED ON
SHEET GI .2, TYPICAL.
0 PROVIDE CAULKING AS INDICATED ON
SHEET GI .2, TYPICAL.
0 PROVIDE SEALANTS AS INDICATED ON
SHEET GI .2, TYPICAL.
® PATCHING AS INDICATED ON G1.2, TYPICAL.
CD APPLICATION OF PAINT AS INDICATED ON
WORK SHEET GI .2, TYPICAL.
0 PAINT EXTERIOR DOOR AND DOOR FRAME, TYPICAL.
CD PROTECT IN PLACE All SIGNAGE, FIRE EXTENGUSHER, PIPES, CONNECTIONS, RAILS, LIGHTS, FIRE DEVICES, AND ANY OTHER EQUIPMENT.
TYPICAL.
D
LEGEND
EXISTING NON-RATED PARTITION
EXISTING ELEMENT TO BE REMOVED OR MODIFIED
EXISTING ELEMENT TO REMAIN
DEMOLITION KEY NOTE
REMODEL KEY NOTE
AREA NOT IN CONTRACT SCOPE (N.I.C.)
GENERAL NOTES
DEMOLITION WORK:
1. CONTRACTOR SHALL COORDINATE WITH DISTRICT'S
REPRESENTATIVES IF & WHEN EXISTING ELEMENTS SUCH AS
WALLS, CEILINGS, DOORS, FIXTURES, ETC. INDICATED TO BE REMOVED
SHALL HAVE CONFLICT &/OR IMPACT TO CONSTRUCTION
PROCEDURES.
2 CONTRACTOR TO EXERCISE EXTRA CARE TO ENSURE EXISTING
ELEMENTS INDICATED TO REMAIN Will NOT BE DAMAGED DURING DEMOLITION. COi'ITRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR
OF THE DAMAGED ELEMENT & RESTORE TO ITS ORIGINAL
CONDITION AT OWN EXPENSE.
REMODEL WORK:
I. VERIFY ALL DIMENSIONS & CONDITIONS AT THE SITE. REPORT
CONDITIONS DISCOVERED THAT ARE NOT RECOGNIZED BY THESE
DOCUMEr,/JS TO THE DESIGN PROFESSIONAL IN GENERAL
RESPONSIBLE CHARGE.
2. All DIMENSIONS TO F.O.F., U.N.O.
4.
DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED.
REFER TO SPECIFICATION FOR FINISHES.
USE DRYWALL SCREW ANCHORS FOR ATTACHMENT OF ALL WALL
MOUNTED ACCESSORIES, EQUIPMENT, & FURNITURE ITEMS LESS
THAN 20 LBS. WITHOUT BACKING.
REPAIR (E) FINISH, PATCH I PAINT WALL TYPICAll Y FOR EVERY
REMOVAL OF WALL MOUNTED EQUIPMENT, ARTWORK, SIGNAGE,
WALL PROTECTION.
N
E9
BUILDING 26ABCD 3RD FLOOR PLAN
N.T.S
MT.SAC
Mt. San Antonio College
1100 NORT H GRAND AVENUE
WALNU T, CA 91789-139 9
www.mtsac.edu 909.274.7500
C:
·a;
I a, C: a, en
:z c:::
u en
,ij
� c:::
u
'if.
cc
<D z
Ii:
c:::
uen w
� '--'--L--" drawing data:
DATE: 0512512026
SHEET SIZE: 24 X 36
FILENAME: .dwg
DRAWN BY: QC
CHECKED BY: QC
COPYRIGHT:
MT. SAN ANTONIO COLLEGE
key plan:
I 2S,\ r 26B 26C, I 260 project title:
BUILDING
26ABCD
EXTERIOR
REPAINT
PROJECT
sheet name:
BUILDING
26ABCD
3RD FLOOR
PLAN
sheet number.
A 1.2
SHEET #OF#
A2.0
BUILDING
26ABCD
ELEVATIONS
FOR REFERENCE ONLY
A2.1
26ABCD
A2.2
26ABCD
A2.3
26ABCD
| _G1.0 Layout1 (1) |
| _G1.1 Layout1 (1) |
| _G1.2 Layout1 (1) |
| _G1.3 Layout1 (1) |
| A0.0_Bldg26ABCD_Overall Plan Layout1 (1) |
| A1.0_Bldg26ABCD_1ST Floor Plan Layout1 (1) |
| A1.1_Bldg26ABCD_2ND Floor Plan Layout1 (1) |
| A1.2_Bldg26ABCD_3RD Floor Plan Layout1 (1) |
| A2.0_ELEVATIONS |
| A2.1_ELEVATIONS |
| A2.2_ELEVATIONS |
| A2.3_ELEVATIONS |
File details come from the government source that posted it. Updated .