BRKR 202911 GLOBAL ASNT STORAGE TYPE B3 DRAWINGS SIGNED.pdf
PDF 6 MB Posted
- Attached to
- 117 ARW Global ASNT Transportable Building Federal contract opportunity
- Solicitation number
- W50S6M-23-B-0002
About this file
This federal contract opportunity notice describes requirements for construction services for the Global ASNT Transportable Building project at the 117th Air Refueling Wing in Birmingham, Alabama. The solicitation will be an invitation for bids set aside for small businesses, with a NAICS code of 236220 and size standard of $45 million. Construction is estimated between $250,000 to $500,000. The pre-bid conference will be held on April 5th, with questions due by March 28th and bids due on April 26th. The contract performance period is 210 calendar days. The project includes construction of a transportable building in accordance with the attached plans and specifications, which require Best Doors Locks brand locks valued at $3,000. Interested parties must register in SAM.gov and the solicitation will be posted to Contract Opportunities at SAM.gov.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Global ASNT Justification and Approval for Other than Full and Open Competition 2 sv KO 2.pdf | ||
| BRKR 202911 GLOBAL ASNT STORAGE TYPE B3 SPECS SIGNED.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T1.0
TITLE SHEET &
DRAWING INDEX
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
DRAWING INDEX
SHEET NO. SHEET NAME
04 ARCHITECTURAL
A1.0 DEMOLITION NOTES & PLAN
A2.1 PLANS & ELEVATIONS
A3.2 DOOR & FINISH SCHEDULES
A5.1 DETAILS & WALL SECTIONS
05 STRUCTURAL
S0.1 GENERAL NOTES- SCHEDULES- TYPICAL DETAILS
S1.1 FRAMING PLANS- SECTIONS & DETAILS
06 FIRE PROTECTION
FA1.1 FIRE ALARM NEW WORK PLAN
FX1.1 FIRE SPRINKLER NEW WORK PLAN
07 MECHANICAL
M1.1 MECHANICAL NEW WORK PLAN, SCHEDULES AND CONTROLS
09 ELECTRICAL
E1.1 SYMBOLS, NOTES AND LIGHTING FIXTURE
E2.1 LIGHTING, POWER AND AUXILIARIES PLANS
DRAWING INDEX
SHEET NO. SHEET NAME
00 TITLE
T1.0 TITLE SHEET & DRAWING INDEX
T2.0 GENERAL WORK NOTES, ABBREVIATIONS & SYMBOLS
T3.0 TYPICAL MOUNTING HEIGHTS & CLEARANCES
01 LIFE SAFETY
LS1.0 LIFE SAFETY PLAN & CALCULATIONS
03 CIVIL
C1.1 SITE DEMOLITION PLAN
C2.1 SITE LAYOUT AND UTILITIES PLAN
C3.1 SITE GRADING & DRAINAGE PLAN AND EROSION &
SEDIMENTATION CONTROL PLAN
C4.1 SITE DETAILS
C5.1 SITE DETAILS
Mechanical:
Approvals:
Title: Signature: Date:
Base Commander
Base Civil Engineer
Base Project Engineer
Bio Environmental Eng.
Safety
Security Police
Base Communications
Fire Chief
Using Agent
Global ASNT Storage Facility 117th Air Refueling Wing
BRKR 042033
Birmingham IAP (ANG), AL
Architect:
Design Team: Consulting Engineers:
Electrical: Civil: Structural: Rev. Description Date
202A
A101
1Ref
Re f
1 Ref
Re f
A101
Ref
1Re f
1 Re f
Ref
ROOM NAME
150 SF
1t
1i
A101
SIM
A101
SIM
A101
SIM
BUILDING ELEVATION TAG
INTERIOR ELEVATION TAG
BUILDING SECTION TAG
WALL SECTION TAG
DETAIL TAG
General Symbol Legend
ROOM TAG
ADA APPROVED TURNING SPACE
SPOT ELEVATION
DOOR TAG (SEE DOOR SCHEDULE)
WINDOW TAG (SEE WINDOW SCHEDULE)
WALL/STOREFRONT TAG (SEE
WALL/STOREFRONT SCHEDULE)
REVISION TAG (SEE REVISION SCHEDULE)
X SPECIFIC NOTE TAG
ELECTRIC WATER COOLER (SEE PLUMBING)
FIRE EXTINGUISHER CABINET
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T2.0
GENERAL WORK
NOTES,
ABBREVIATIONS &
SYMBOLS
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
General Project Notes:
GENERAL NOTES APPLY TO THE ENTIRE PROJECT. SPECIFIC NOTES APPLY TO ISOLATED
WORK AREAS AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR. HOWEVER, ALL
ISOLATED WORK AREAS ARE NOT NOTED. SHOULD A CONDITION OCCUR THAT IS NOT
SPECIFICALLY NOTED, THE CONTRACTOR SHALL PROCEED WITH WORK PER GENERAL
DEMOLITION NOTES OR A SPECIFIC WORK NOTE(S) USED IN OTHER SIMILAR
CONDITIONS, WHICHEVER IS MORE STRINGENT, PER APPROVAL OF ARCHITECT.
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY CONDITIONS
1. CONTRACTOR TO VISIT SITE AND TO BECOME TOTALLY FAMILIAR WITH EXTENT OF
WORK REQUIRED PRIOR TO BID.
2. DIMENSIONS OF EXISTING STRUCTURES ARE ONLY FOR THE CONVENIENCE OF THE
CONTRACTOR, VERIFY ALL EXISTING CONDITIONS. LOCATION OF WALLS SHALL BE
AS SHOWN ON PLAN RELATIVE TO EXISTING CONDITIONS.
3. CONTRACTOR TO VERIFY ALL DIMENSIONS AND FIELD CONDITIONS WITH THE
DRAWINGS, IN PARTICULAR: WALL DIMENSIONS, INCOMING UTILITIES, ETC. REPORT
IMMEDIATELY TO THE GOVERNMENT ANY VARIANCES OR FIELD CONDITIONS THAT
MAY CAUSE CONSTRUCTION PROBLEMS PRIOR TO COMMENCING WORK.
CONTRACTOR'S REPONSIBILITY TO COORDINATE THE WORK
1. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO COMMENCING.
FURNISH INFORMATION NECESSARY TO ADJUST, MOVE OR RELOCATE EXISTING
STRUCTURES, UTILITY POLES, LINES, SERVICES OF OTHER SYSTEMS LOCATED IN,
OR AFFECTED BY CONSTRUCTION. COORDINATE WITH LOCAL AUTHORITIES
HAVING JURISDICTION WITH CONSTRUCTION.
2. CONTRACTOR TO VERIFY APPLICABLE OPENINGS, DOOR SIZES, AND DIMENSIONS
OF MECHANICAL ROOMS WITH EQUIPMENT. IF DISCREPANCY OCCURS, NOTIFY
THE GOVERNMENT PRIOR TO FRAMING.
3. CONTRACTOR TO COORDINATE PLUMBING AND MECHANICAL LINES WITH CEILING
HEIGHTS, ABOVE CEILING AREAS AND STRUCTURAL ELEMENTS.
4. CONTRACTOR TO VERIFY WITH STRUCTURAL, PLUMBING, MECHANICAL, AND
ELECTRICAL THE QUANTITY AND SIZES OF ALL SLEEVES REQUIRED. ALL SLEEVES
TO BE ONE HOUR RATED, PROVIDE GREATER RATING IF PENETRATING INTO HIGHER
RATED SPACE.
5. COORDINATE CONDUIT, PIPING, AND DUCTWORK SO THAT THE HEAD HEIGHT IS
NOT ENCUMBERED AND SERVICES ARE AS TIGHT UP TO STRUCTURE AS POSSIBLE.
6. CONTRACTOR TO COORDINATE PLUMBING, MECHANICAL, FIRE SPRINKLER,
ELECTRICAL, AND LIGHTING WITH STRUCTURAL ELEMENTS WHERE THERE IS
EXPOSED STRUCTURE. CONDUIT LINES, ECT. SHALL RUN AT RIGHT ANGLES OR
SEGMENTED BETWEEN COLUMN LINES AND BE CLEAN AND NEAT IN APPEARANCE.
7. COORDINATE CONDUIT, PIPING, AND DUCTWORK SO THAT HEAD HEIGHT IS NOT
ENCUMBERED AND SERVICES ARE AS TIGHT UP TO STRUCTURE AS POSSIBLE,
THIS WILL INCLUDE JOGGING DUCTS, SPRINKLER LINES, PLUMBING LINES,
CONDUIT, ECT. UP AND DOWN OR AROUND AS REQUIRED TO ACHIEVE CEILING
HEIGHTS AS INDICATED. COORDINATE INSTALLATION AND SEQUENCING OF
DISCIPLINES TO ACHIEVE.
8. THE GENERAL CONTRACTOR SHALL STAKE OUT ALL MAJOR FEATURES SHOWN ON
THE SITE PLAN TO VERIFY THE SITE LAYOUT RELATIVE TO THE PROPERTY LINES AND
SITE CONDITIONS PRIOR TO ANY UTILITIES OR FOOTINGS BEING INSTALLED.
9. PLUMBING, FIRE-PROTECTION, MECHANICAL, AND ELECTRICAL WORK REQUIRED BY
THIS CONTRACT IS NOTED ON CONTRACT DOCUMENTS. THE TRADE
CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF THEIR WORK
WITH ALL TRADES. CHANGE ORDERS SHALL NOT BE APPROVED FOR EXTRA WORK
ARISING FROM TRADE CONTRACTORS NOT COORDINATING WORK.
10. CONTRACTOR WILL BE RESPONSIBLE FOR ALL LAYOUT FOR INTERIOR/EXTERIOR
WALLS AND FOUNDATION AND WILL BE RESPONSIBLE FOR MAINTAINING A
BENCHMARK AND CONTROL LINES AT EACH FLOOR LEVEL. CONTRACTOR IS ALSO
RESPONSIBLE FOR VERIFYING ACTUAL FLOOR HEIGHTS AND COORDINATING NEW
AND EXISTING FLOORS TO ALIGN.
11. CONTRACTOR SHALL COORDINATE TO ASSURE ALL EQUIPMENT CAN BE BROUGHT
INTO THE BUILDING. THIS INCLUDES MANUFACTURE COMPONENT SIZE/ASSEMBLY,
CRITICAL PATH SCHEDULING, AND COORDINATION OF OTHER TRADES.
ACT Acoustical Ceiling Tile A/C Air Conditioning AB Anchor Bolt ADA American Disabilities Act AFF Above Finish Floor BM Beam BRG Bearing BRK Brick CFCI Contractor Furnished
Contractor Installed CIP Cast In Place CJ Control Joint CL Column Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit COL Column CONC Concrete CONT Continuous CONTR Contractor COORDF Coordination CORR Corridor CT Ceramic Tile CTR Center DBL Double DET Detail DIA Diameter DR Drain DN Down DS Downspout DW Dishwasher DWG Drawing DWR Drawer EA Each EF Exhaust Fan EJ Expansion Joint EL Elevation ELEC Electrical EQ Equal EX Existing EXT Exterior FF Finish Floor FIN Finish FL Floor Line FlSNG Flashing FTG Footing GA Gauge GFRC Glass Fiber Reinforced
Concrete
GWB GWB
HT Height HM Hollow Metal HOR Horizontal HR Handrail HTR Heater HVAC Heating, Ventilation & Air
Conditioning HxWxL Height, width, length IN Inches INSUL Insulation INT Interior JST Joist
JT Joint LAM Laminate LAV Lavatory LVR Louver MIN Minimum MAX Maximum MECH Mechanical MET Metal MFR Manufacturer MH Man Hole MIN Minimum MISC Miscellaneous MLDG Moulding MO Masonry Opening MTD Mounted MW Microwave NIC Not In Contract NO Number NOM Nominal NTS Not to Scale OC On Center OFCI Owner Furnished
Contractor Installed OFOI Owner Furnished
Owner Installed OPP Opposite P Paint PL Plate / Property Line PL LAM Plastic Laminate PLYWD Plywood PNL Panel PT Pressure Treated R Radius / Riser RB Rubber Base REFR Refrigerator REINF Reinforce (D) REV Revised RM Room SCHED Schedule SECT Section SHT Sheet SHW Single Hung Window SIM Similar SPECS Specifications SQ Square SS Sanitary Sewer STD Standard SVT Solid Vinyl Tile STL Steel T Tile T&G Tongue & Groove TYP Typical UNO Unless Noted
Otherwise VERT Vertical VTR Vent Thru Roof VWC Vinyl Wall Covering WD Wood WWM Welded Wire Mesh WWF Welded Wire Fabric YP Yellow Pine
Typical Abbreviation Legend:General Project Notes (Continued):
CONTRACTOR'S RESPONSIBILTY TO COMPLY WITH APPLICABLE GOVERNING
CODES/AUTHORITIES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, LAWS,
AND ORDINANCES. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR
OBTAINING ALL PERMITS, INSPECTIONS, AND CERTIFICATES REQUIRED BY
GOVERNING ENTITIES.
2. CONTRACTOR TO CONFIRM ALL OSHA AND APPLICABLE STANDARDS TO
ASSURE SAFETY OF ALL PERSONS ON SITE DURING ENTIRE COURSE OF
CONSTRUCTION.
3. NEITHER THE ARCHITECT, NOR THE GOVERNMENT SHALL BE RESPONSIBLE
FOR JOB SAFETY. EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR
JOB SITE SAFETY AND SAFETY OF THE PUBLIC DURING CONSTRUCTION AND
SHALL PROVIDE APPROPRIATE WARNINGS, BARRICADES, ETC. AS REQUIRED
PER CODES.
4. PROMPTLY NOTIFY THE GOVERNMENT IN WRITING IF ANY CONTRACT
DOCUMENTS ARE FOUND TO BE IN VARIANCE WITH THE APPLICABLE LAWS
AND ORDINANCES. NECESSARY CHANGES WILL BE MADE BY APPROPRIATE
MODIFICATIONS.
5. IF ANY WORK IS PERFORMED KNOWING IT TO BE CONTRARY TO SUCH CODES,
LAWS, ORDINANCES, RULES AND REGULATIONS, AND WITHOUT NOTICE TO
THE GOVERNMENT, THAT TRADE CONTRACTOR ASSUMES FULL
RESPONSIBILITY AND BEARS COSTS ATTRIBUTED TO BRING WORK TO
COMPLIANCE OF SUCH CODES, LAWS, ORDINANCES, AND RULES AND
REGULATIONS.
GENERAL PROVISIONS FOR FIRE RATED CONSTRUCTION
1. ALL RECESSED ACCESSORIES LOCATED IN FIRE RATED WALLS SHALL BE
EITHER OF FIRE RATED CONSTRUCTION OR COORDINATED WITH THE
ADJACENT TRADES TO ALLOW THE GYPSUM BOARD TO BE CONTINUOUS
BEHIND THE ACCESSORIES.
2. EACH RESPONSIBLE CONTRACTOR SHALL SEAL ALL PENETRATIONS MADE AS
PART OF THEIR WORK IN FIRE-RATED CONSTRUCTION AS REQUIRED BY ALL
APPLICABLE CODES. EACH CONTRACTOR TO VERIFY WITH LOCAL FIRE
MARSHAL OR BUILDING OFFICIAL HAVING JURISDICTION. EACH RESPONSIBLE
CONTRACTOR WILL SEAL ALL PENETRATIONS MADE AS PART OF THEIR WORK
THROUGH NON-RATED PARTITIONS. ALL FIRE CAULK TO BE THE SAME BRAND
AS DETERMINED BY CONTRACTOR.
3. ALL NEW AND EXISTING FIRE WALLS IN WORK AREAS ARE TO BE CARRIED TO
THE UNDERSIDE OF THE ROOF DECK AND SEALED AS REQUIRED FOR
NECESSARY FIRE RATINGS, AND LABELED PER THE AUTHORITY HAVING
JURISDICTION.
4. MATERIALS WITHIN PLENUMS. EXCEPT AS REQUIRED BY THE 2009
INTERNATIONAL MECHANICAL CODE SECTION 602.2.1.1 THROUGH
602.2.1.6, MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR
SHALL HAVE A FLAME SPEAD INDEX OF NOT MORE THAN 25 AND A SMOKE-
DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE
WITH ASTM E84 OR UL 723.
MISCELLANEOUS GENERAL PROVISIONS:
1. CONTRACTOR TO NOTIFY THE GOVERNMENT IMMEDIATELY IF THERE ARE ANY
DISCREPANCIES WITH TAGGED DETAILS, ENLARGED PLANS, ELEVATIONS, ETC.
2. IN ROOMS WITH FLOOR DRAINS, SLOPE TO DRAIN AT 1 PERCENT SLOPE
UNLESS SPECIFICALLY NOTED OTHERWISE.
Rev. Description Date
" M
IN
18" MIN
(A)
FRONT APPROACH, PULL SIDE
" M
IN
(B)
FRONT APPROACH, PUSH
SIDE
" M
IN12" MIN
(C)
FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
36" MIN
" M
IN
(D)
HINGE APPROACH, PULL SIDE
42" MIN
" M
IN
(E)
HINGE APPROACH, PULL SIDE
" M
IN
22" MIN
(F)
HINGE APPROACH, PUSH SIDE
(G)
HINGE APPROACH, PUSH SIDE, DOOR
PROVIDED WITH BOTH CLOSER AND
LATCH
" M
IN
22" MIN
24" MIN
" M
IN
(H)
LATCH APPROACH, PULL SIDE
(I)
LATCH APPROACH, PULL SIDE,
DOOR PROVIDED WITH CLOSER
" M
IN 24" MIN
24" MIN
" M
IN
(J)
LATCH APPROACH, PUSH SIDE
(K)
LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
24" MIN
" M
IN
" M
IN12" MIN
(C)
PUSH SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
X > 8"4
" M
IN
(B)
PUSH SIDE
" M
IN
18" MIN
X > 8"
(A)
PULL SIDE
24" MIN
" M
IN
(D)
STOP OR LATCH APPROACH
22 MIN
m in
(C)
POCKET OR HINGE APPROACH
(B)
SIDE APPROACH
M
IN
m in
(A)
FRONT APPROACH
AREA OF
REFUGE
AREA OF
REFUGE
" M
IN
" M
A X
CL
18 MIN
M
IN
CENTERED ON RAISED CHARACTERS
HEIGHT OF RAISED CHARACTERS ABOVE FLOOR LOCATION OF SIGNS AT DOORS
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T3.0
TYPICAL
MOUNTING
HEIGHTS &
CLEARANCES
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
1. ADA STANDARDS FOR ACCESSIBLE DESIGN AND ICC/ANSI A117.1 ARE THE REFERENCE
STANDARDS USED FOR SCOOPING PROVISIONS FOR ACCESSIBILITY. THE MORE STRINGENT
PROVISIONS OF THE TWO STANDARDS ARE INDICATED.
2. DIAGRAMS SHOWN ARE FOR MOUNTING HEIGHT INFORMATION ONLY. FIXTURES SHOWN ARE NOT
NECESSARILY INCLUDED IN THE PROJECT.
3. COORDINATE ADA REQUIREMENTS WITH ALL REQUIRED CONCEALED WOOD BLOCKING.
4. REFER TO MANUFACTURER'S LITERATURE REGARDING RECOMMENDATIONS FOR MOUNTING
PRODUCTS AND MATERIALS IN COMPLIANCE WITH ADA STANDARDS.
GENERAL NOTES:
3/8" = 1'-0"T3.0
5 ADA DOOR OPENING MANEUVERING CLEARANCES
1/8" = 1'-0"T3.0
1 TYPICAL SIGNAGE MOUNTING DIAGRAMS
HANDICAP ACCESSIBLE EXIT LOCATION
EXIT TRAVEL PATH
ELECTRIC WATER COOLER - SEE PLUMBING
EWC
EMERGENCY EXIT SIGNAGE
LIFE SAFETY LEGEND
FIRE EXTINGUISHER BRACKETFEB
AUTOMATED EXTERNAL DEFIBRILLATORAED
ROOM TAG
ROOM NAME
150 SF
B - MECHANICAL
B - CONCENTRATED B - GENERAL
S-1: STORAGE
8038 SF
S-1 (STORAGE)
1325 SF
B (CONCENTRATED)
383 SF
B (CONCENTRATED)
632 SF
B (MECHANICAL)
834 SF
B (CONCENTRATED)
302 SF
B (GENERAL)
EXIT ACCESS TRAVEL
DISTANCE =71'
FEB
FEB
FEB
FEB
FEB
FEB
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
LS1.0
LIFE SAFETY PLAN
& CALCULATIONS
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
CODE SUMMARY
APPLICABLE CODES:
BUILDING CODE..............UFC 1-200-01 / 2018 INTERNATIONAL BUILDING CODE
STRUCTURAL CODE...........UFC 3-301-01
PLUMBING CODE............UFC 3-420-01
MECHANICAL CODE.........UFC 3-401-01
FIRE CODE..................UFC 3-600-01 / NFPA 101
ELECTRICAL CODE...........UFC 3-501-01
ENERGY CODE..............UFC 1-200-02
ACCESSIBILITY CODE......2010 ADA STANDARDS
LIFE SAFETY CODE........UFC 3-600-01
IBC CHAPTER 3 AND UFC 3-600-01 OCCUPANCY & USE:
NFPA 101 CHAPTER 6:
• SEE LEGEND ON LIFE SAFETY PLAN
IBC CHAPTER 4 - SPECIAL DETAILED REQUIREMENTS:
• NOT APPLICABLE
IBC CHAPTER 5 - GENERAL BUILDING HEIGHTS & AREAS:
• CONSTRUCTION TYPE = II-B, SPRINKLED, GROUP S-1
• ALLOWABLE BUILDING HEIGHT (PER TABLE 504.3)
75 FEET ABOVE GRADE PLANE
• ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (PER TABLE 504.4)
3 STORIES ABOVE GRADE PLANE
• TABULAR BUILDING AREA (PER TABLE 506.2)
70,000 SQUARE FEET
• FIRE SEPARATION REQUIREMENTS NONSEPARATED OCCUPANCIES
• INCIDENTAL USE AREAS (PER TABLE 509)
SEE OCCUPANCY TABLE.
IBC CHAPTER 6 TYPES OF CONSTRUCTION:
• CONSTRUCTION TYPE: II-B
• FIRE RATINGS (PER TABLE 601) AS FOLLOWS (EXCEPT WHERE NOTED OTHERWISE)
PRIMARY STRUCTURAL FRAME.............................. 0 HOUR
BEARING WALLS (INTERIOR & EXTERIOR)...................0 HOUR
NON-BEARING WALLS AND PARITIONS (INTERIOR)........0 HOUR
FLOOR CONSTRUCTION AND SECONDARY MEMBERS...0 HOUR
ROOF CONSTRUCTION AND SECONDARY MEMBERS....0 HOUR
• REQUIRED FIRE SEPERATION (PER TABLE 602)
OCCUPANCY TYPE FIRE SEPARATION REQ. RATING
B >30' 0 HR
S-1 >30' 0 HR
IBC CHAPTER 7 - FIRE AND SMOKE PROTECTION FEATURES:
• MAXIMUM EXTERIOR WALL OPENINGS (PER IBC SECTION 705)
DEGREE OF OPENING PROTECTION: ALLOWABLE AREA:
UNPROTECTED, SPRINKLERED , (UP, S) NO LIMIT
• FIRE WALLS (PER NFPA 8.3.2)
NO FIRE WALLS ARE PRESENT WITHIN THE SCOPE OF THE PROJECT
• SHAFT ENCLOSURE (PER NFPA 8.3.1 / 7.3.1.2)
NOT APPLICABLE
• OPENING PROTECTIVES (PER NFPA 8.3.4)
TYPE OF ASSEMBLY ASSEMBLY RATING REQUIRED OPENING PROTECTION
NOT APPLICABLE
• CONCEALED SPACES (PER SECTION 718)
NOT APPLICABLE
• SEE LEGEND ON LIFE SAFETY PLAN FOR APPLICABLE UL ASSEMBLIES TO BE PROVIDED.
IBC CHAPTER 8, UFC 3-600-01, NFPA 101 - INTERIOR FINISHES:
• FINISH MATERIAL RATING REQUIREMENTS (PER NFPA 101)
BUSINESS (CHAPTER 39)
INTERIOR WALL AND CEILING FINISH - CLASS A, B, OR C (42.3.3.2)
STORAGE S-1 (CHAPTER 42)
INTERIOR WALL AND CEILING FINISH - CLASS A, B, OR C (42.3.3.2.2)
UFC 3-600-01(REPLACES IBC CHAPTER 9) - FIRE PROTECTION SYSTEMS:
• SECTION 9-1 - EMERGENCY VEHICLE ACCESS
1. FACILITY REQUIRES ONE MEANS OF ALL-WEATHER EMERGENCY
VEHICLE GROUND ACCESS IN ACCORDANCE WITH 9-1.1
2. FACILITY DOES NOT REQUIRE AERIAL APPARATUS ACCESS IN
ACCORDANCE WITH 9-1.2
• SECTION 9-2 - FIRE FLOW FOR FACILITIES
1. FIRE FLOW FOR SPRINKLER SYSTEM IS PROVIDED IN ACCORDANCE
WITH 9-2.1
• SECTION 9-3 - SERVICE MAINS AND LATERALS
1. FIRE HYDRANTS ARE PROVIDED IN ACCORDANCE WITH 9-3.5.8.2
A. ALL PARTS OF THE FACILITY EXTERIOR ARE WITHINT 350 FT OF
A HYDRANT
2. FIRE HYDRANTS ARE PROVIDED IN ACCORDANCE WITH 9-3.5.8.4
A. ONE HYDRANT IS LOCATED WITH 150FT OF THE FIRE
DEPARTMENT CONNECTION
• SECTION 9-5 - FIRE PUMPS
1. A FIRE PUMP IS NOT REQUIRED TO MEET FIRE PROTECTION
DEMAND
• SECTION 9-7 - AUTOMATIC SPRINKLER SYSTEMS
1. PER 9-7.2.1, AN AUTOMATIC SPRINKLER SYSTEM IS REQUIRED
• SECTION 9-10 - STANDPIPE SYSTEMS
1. PER 9-10, A STANDPIPE SYSTEM IS NOT REQUIRED
• SECTION 9-17 - PORTABLE FIRE EXTINGUISHERS
1. FIRE EXTINGUISHERS ARE PROVIDED, SEE PLANS FOR LOCATIONS
NFPA CHAPTER 7 (REPLACES IBC CHAPTER 10) - MEANS OF EGRESS:
• OCCUPANCY LOAD (PER TABLE 7.3.1.2):
SEE OCCUPANCY TABLE
• EGRESS CAPACITY SIZING (PER TABLE 7.3.3.1)
SEE CODE CALCULATIONS TABLE(S)
SEE LIFE SAFETY PLAN FOR INDIVIDUAL ROOM EGRESS ANALYSIS
• MINIMUM STAIR WIDTH (PER SECTION 7.3.3.1)
SEE CODE CALCULATIONS TABLE(S)
• NUMBER OF MEANS OF EGRESS (PER SECTION 7.4.1)
TOTAL NUMBER OF EXITS REQUIRED
BUSINESS OCCUPANCY (CHAPTER 39)
2 EXITS REQUIRED
S-1 STORAGE OCCUPANCY (CHAPTER 42)
2 EXITS REQUIRED
• COMMON PATH OF EGRESS TRAVEL DISTANCE
BUSINESS OCCUPANCY (CHAPTER 39)
100 FT PER 39.2.5.2.1
S-1 STORAGE (CHAPTER 42)
100 FT PER 42.2.5
• EXIT ACCESS TRAVEL DISTANCE
BUSINESS OCCUPANCY (CHAPTER 39)
300 FEET PER 39.2.6.3
S-1 STORAGE OCCUPANCY (CHAPTER 39)
400 FEET PER 42.2.5
• CORRIDORS
OCCUPANCY TYPE (B, S-1) REQUIRES:
NO FIRE RATING REQUIRED FOR CORRIDOR WALLS
MINIMUM CORRIDOR WIDTH
BUSINESS OCCUPANCY (CHAPTER 39)
44 INCHES PER 39.2.3.2
S-1STORAGE OCCUPANCY (CHAPTER 42)
36 INCHES PER 7.3.4.1
DEAD END CORRIDORS
BUSINESS OCCUPANCY (CHAPTER 39)
MAXIMUM OF 50 FEET PER 39.2.5.3
S-1 STORAGE OCCUPANCY (CHAPTER 42)
MAXIMUM OF 100 FEET PER 42.2.5
SSL_GROUND FLOOR PLAN CODE CALCULATIONS
Name
Occupancy Calculations Egress Width Calculations
Area Male
Occupancy Female
Occupancy Occupancy
Factor Total Occupant
Load Req. Width Of Egress
Components
B (CONCENTRATED) 834 SF 13.35 3.34 50 SF 16.68 3.34
B (CONCENTRATED) 383 SF 6.13 1.53 50 SF 7.66 1.53
B (CONCENTRATED) 1325 SF 21.20 5.30 50 SF 26.50 5.30
B (GENERAL) 302 SF 2.42 0.60 100 SF 3.02 0.60
B (MECHANICAL) 632 SF 1.01 0.25 500 SF 1.26 0.25
S-1 (STORAGE) 8038 SF 12.86 3.22 500 SF 16.08 3.22
11515 SF
3/32" = 1'-0"LS1.0
1 LIFE SAFETY PLAN
SSL_PLUMBING FIXTURE CALCULATIONS
Name Male
Occupancy Female
Occupancy
Plumbing Fixture Calculations Water Closets Required Lavatories Required Drinking
Fountains Req.Men Women Male Female.
B (CONCENTRATED)
B (GENERAL) 2.42 0.6 0.10 0.02 0.06 0.02 0.03
B (MECHANICAL) 1.01 0.25 0.04 0.01 0.03 0.01 0.01
S-1 (STORAGE) 12.79 3.2 0.51 0.13 0.32 0.08 0.16
Rev. Description Date
57 15 72 14.24 CALCULATED
44" MINIMUM REQUIRED PER CODE
57 15 3 1 2 1 1
466 SF
MECH.
EQUIPMENT
30-06
2851 SF
ENGINE SHOP
30-08
1882 SF
REPAIR &
RECLAIM
30-14
351 SF
OFFICE
30-05
202 SF
MEN
30-03
281 SF
OFFICE
30-02
497 SF
READY ROOM
30-01
1858 SF
NON-POWERED
AGE
30-13
673 SF
MAINTENANCE
STORAGE
30-12286 SF
OFFICE
30-11
111 SF
ELEC. ROOM
30-07
47 SF
WOMEN
30-04
536 SF
C.A.T.M.
30-09
144 SF
OFFICE
30-15
280 SF
C.A.T.M.
WAREHOUSE
30-10
LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
DOTTED LINE GENERALLY INDICATES EXISTING AREAS TO BE
REMOVED, INCLUDING BUT NOT LIMITED TO WALLS, DOORS,
FLOOR COVERING, CEILINGS, ETC... IN CASE OF UNCERTAINTY
PROVIDE WRITTEN REQUEST TO ARCHITECT.
xx SPECIFIC NOTE TAG (SEE
DEMOLITION NOTES SHEET)
REMOVE SLAB IN LOCATION
MARKED IN PREPARATION FOR
NEW WORK
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A1.0
DEMOLITION
NOTES & PLAN
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
General Demolition Notes:
THE INTENT OF DEMOLITION IS TO ACCOMPLISH ALL WORK NECESSARY TO PROVIDE A FINISHED, COMPLETE BUILDING AS INDICATED IN THE PLANS AND SPECIFICATIONS. THE FOLLOWING GENERAL NOTES ARE APPLICABLE
TO ALL DEMOLITION ACTIVITIES REQUIRED BY THE SCOPE OF THE CONTRACT DOCUMENTS.
CONTRACTOR'S RESPONSIBILTY TO VERIFY ACCURACY OF EXISTING CONDITIONS:
1. DOCUMENTATION CONTAINED IN THESE CONSTRUCTION DOCUMENTS OF EXISTING CONDITIONS MAY
NOT BE ENTIRELY ACCURATE. CONTRACTOR IS TO TAKE THE INITIATIVE TO VISIT THE SITE PRIOR TO AND
DURING THE PRE-BID MEETING TO VERIFY ACTUAL CONDITIONS, THEREFORE RENDERING THE
CONTRACTOR RESPONSIBLE FOR AN ACCURATE REPRESENTATION OF THE EXISTING CONDITIONS.
2. CONTRACTOR TO VISIT SITE TO VERIFY EXISTING CONDITIONS AND SHALL BE RESPONSIBLE FOR
DETERMINING THE SCOPE OF WORK PRIOR TO DEMOLITION . EXISTING CONDITIONS SHALL BE
THOROUGHLY RESEARCHED PRIOR TO CONSTRUCTION AND ANY DRAWINGS SHALL BE IMMEDIATELY DISCUSSED WITH ARCHITECT PRIOR TO BEGINNING CONSTRUCTION IN THE AFFECTED AREA. CHANGE ORDERS WILL NOT BE APPROVED PRIOR TO WORK TAKING PLACE FOR EXISTING CONDITIONS READILY
APPARENT BY A THOROUGH OBSERVATION.
3. CONTRACTOR TO VERIFY ALL EXISTING FLOOR ELEVATIONS AND VERIFY WITH PLANS. REPORT ANY
DISCREPANCIES TO THE GOVERNMENT PRIOR TO CONSTRUCTION
4. DIMENSIONS OF EXISTING STRUCTURES ARE ONLY FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. LOCATION OF WALLS SHALL BE AS SHOWN ON
PLANS RELATIVE TO EXISTING CONDITIONS.
5. THE GOVERNMENT ASSUMES NO RESPONSIBILITY FOR EXISTING UNKNOWN CONDITIONS. EACH
CONTRACTOR SHALL COORDINATE NEW CONSTRUCTION WITH EXISTING CONSTRUCTION AND
INVESTIGATE IN A REASONABLE MANNER REGARDING HIDDEN CONDITIONS.
SAFEGUARDS DURING DEMOLITION:
1. CONTRACTOR TO MAKE SURE ALL INFRASTRUCTURE (POWER, GAS, WATER, CABLING, ETC...) IS TURNED
OFF AND/OR REMOVED PRIOR TO DEMOLITION.
2. CONTRACTOR TO VERIFY ALL LOAD BEARING CONDITIONS AND PROVIDE SHORING AS REQUIRED IN ALL
AFFECTED AREAS PRIOR TO & DURING DEMOLITION AND/OR CONSTRUCTION.
3. ALL CURRENT OSHA AND APPLICABLE STANDARDS SHALL BE UPHELD TO ASSURE SAFETY OF ALL
PERSONS ON SITE DURING ENTIRE COURSE OF CONSTRUCTION.
4. PROTECT ALL EXISTING BUILT IN EQUIPMENT AS REQUIRED DURING DEMOLITION AND CONSTRUCTION
ACTIVITIES. CONTRACTOR SHALL REPAIR ANY DAMAGE TO EXISTING EQUIPMENT RESULTING FROM CONSTRUCTION ACTIVITIES AT NO COST TO THE GOVERNMENT. VERIFY CONDITIONS OF EXISTING EQUIPMENT WITH THE GOVERNMENT PRIOR TO BEGINNING ON SITE DEMOLITION AND CONSTRICTION
ACTIVITIES.
CONTRACTOR'S RESPONSIBILTY TO REMOVE ALL ENCUMBRANCES REQUIRED FOR PROPER INSTALLATION OF
NEW SYSTEMS:
1. REMOVAL OF ALL ENCUMBRANCES INCLUDING BUT NOT LIMITED TO CONCRETE, WOOD, DUCTS, PIPING, WIRING, SHALL BE DONE BY THE CONTRACTOR TO ACHIEVE FLOOR PLANS AS SHOWN EVEN IF NOT
SHOWN ON DEMOLITION PLANS.
2. REMOVE ALL CEILINGS AND ITEMS ABOVE CEILINGS THAT ARE NOT REQUIRED IN THE RENOVATED BUILDING AND AS REQUIRED TO INSTALL NEW HVAC, PLUMBING, LIGHTING, ELECTRICAL, ETC. FOR FULLY
FUNCTIONING SYSTEMS.
3. REMOVE ANY UNUSED PENETRATIONS AND INSTALL NEW DECKING/ROOFING OVER ANY OPENINGS
4. UNLESS NOTED OTHERWISE, CONTRACTOR SHALL REMOVE GYPSUM WALLBOARD AND ANY FURRING
STRIPS AND/OR FASTENERS FROM EXTERIOR WALLS TO PREPARE FOR NEW FINISH.
5. REMOVE ALL ABANDONED FIXTURES, PIPING, CONDUIT WIRING, INSULATION, EQUIPMENT, STRUCTURAL
SUPPORTS, ARCHITECTURAL SYSTEMS., ETC… NO LONGER IN USE OR UNNECESSARY FOR THE
RENOVATED PROJECT. PROVIDE PATCHING WITH MATERIALS CONSISTENT WITH ADJACENT MATERIALS
AND FINISHES REQUIRED, UNLESS OTHERWISE NOTED, TO MEET ALL APPLICABLE CODES.
6. REMOVE ALL EXISTING FINISHES AS REQUIRED IN PREPARATION FOR INSTALLATION OF NEW FINISHES. SEE
FINISH SCHEDULE AND PROJECT SPECIFICATIONS.
7. REMOVE ALL MISCELLANEOUS HARDWARE, PANELING, CLIPS, FASTENERS, WIRE, CONDUIT, PIPES, ETC… FROM ANY AND ALL SURFACES TO RECEIVE A NEW FINISH. PATCH SUBSTRATES BY FILLING, GRINDING
AND SANDING SMOOTH WITH ACCEPTABLE CONSTRUCTION INDUSTRY AND CODE COMPLIANT
MATERIALS. PREPARE SURFACE FOR ACCEPTANCE OF MANUFACTURER SPECIFIED FINISH AND SURFACE TREATMENT. INSTALLATION OF FINISH INDICATES ACCEPTANCE OF SUBSTRATE BY APPLICATOR. WHERE NO NEW FINISHES OCCUR, PATCH EXISTING MATERIALS WITH MATCHING MATERIALS SO THAT PATCH
WORK IS NOT VISIBLE.
8. THE CONTRACTOR IS ALSO RESPONSIBLE FOR THE REMOVAL OF DEMOLISHED MATERIALS: FOR THE PATCHING OF EXISTING SURFACES, INCLUDING OPENINGS IN FLOORS, WALLS, ETC. TO MATCH UNDISTURBED EXISTING SURFACES, AND FOR LEAVING THE AREA IN A CLEAN CONDITION. REFER TO
CONTRACT DOCUMENTS FOR SPECIFIC FLOOR RELATED DETAILS.
CONTRACTOR'S RESPONSIBILTY TO RETURN THE SITE/STRUCTURE TO PRE-WORK CONDITIONS
1. CONTRACTOR TO TAKE EXTREME CARE AT EXISTING EXTERIOR FINISHES, INCLUDING BUT NOT LIMITED TO
BRICK, METALWORK, WINDOWS, AND DOORS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY
EXTERIOR FINISHES THAT WERE COMPROMISED DURING THE COURSE OF CONSTRUCTION.
2. CONTRACTOR TO PROTECT ALL FINISHES TO REMAIN ON INTERIOR OF EXISTING SPACES INCLUDING
WALLS, CEILINGS, FLOORS, DOORS, FIXTURES, ETC.
3. CONTRACTOR SHALL LEAVE WORK SITE GENERALLY CLEAN AT THE END OF EACH WORK DAY (ESPECIALLY
AROUND THE EXTERIOR OF THE BUILDING AND WITHIN THE STAGING AREA).
CONTRACTOR'S RESPONSIBILITY REGARDING REMOVAL AND DISPONSAL OF DEMOLISHED MATERIALS:
1. EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LAWS, REGULATIONS, AND/OR ORDINANCES REGARDING THE METHOD OF DEMOLITION AND DISPOSAL OF WASTE MATERIALS.
THE GOVERNMENT ASSUMES NO LIABILITY FOR EXTRA WORK OR ADDITIONAL COMPENSATION DUE TO FAILURE OF THE TRADE CONTRACTOR OR SUBCONTRACTORS TO COMPLY WITH ANY AND ALL SUCH
REGULATIONS THAT APPLY.
General Demolition Notes (Continued):
CONTRACTOR'S RESPONSIBILTY REGARDING HAZARDOUS MATERIALS:
1. CONTRACTOR SHALL COMPLY WITH ALL SPECIFIED REQUIREMENTS AND GOVERNING CODES/LAWS/REGULATIONS
REGARDING REMOVAL AND DISPOSAL OF HAZARDOUS MATERIALS.
2. AN ENVIRONMENTAL ASSESSMENT HAS NOT BEEN COMPLETED.
3. IF HAZARDOUS MATERIALS NOT NOTED IN THE CONTRACT DOCUMENTS ARE ENCOUNTERED, NOTIFY THE
CONTRACTING OFFICER REPRESENTATIVE PRIOR TO PROCEEDING.
ADDITIONAL MISCELLANEOUS PROVISIONS
1. GENERAL DEMOLITION NOTES APPLY TO THE ENTIRE PROJECT. SPECIFIC NOTES (DESIGNATED) APPLY TO ISOLATED
WORK AREAS AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR. HOWEVER, ALL ISOLATED WORK AREAS ARE NOT NOTED. SHOULD A CONDITION OCCUR THAT IS NOT SPECIFICALLY NOTED, THE CONTRACTOR SHALL PROCEED WITH WORK PER GENERAL DEMOLITION NOTES OR A SPECIFIC WORK NOTE(S) USED IN OTHER SIMILAR CONDITIONS, WHICHEVER IS MORE STRINGENT, PER APPROVAL OF ARCHITECT VIA OWNER.
2. REFER ALSO TO SELECTED DEMOLITION, SUMMARY OF WORK, GOVERNMENT SOLICITATION DOCUMENTS, AND OTHER
SPECIFICATION SECTIONS REQUIRED.
3. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, AND STRUCTURAL FOR ADDITIONAL DEMOLITION AND REPARATION REQUIREMENTS. PATCH ALL LOCATIONS REQUIRED BY FIRE SUPPRESSION, PLUMBING, MECHANICAL, AND ELECTRICAL DEMOLITION. MATCH ADJACENT CONDITIONS, UNLESS OTHERWISE NOTED. ALL REQUIRED TRENCHING AND REPLACEMENT OF EXISTING SLABS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
4. DURING ROOFING DEMOLITION PROVIDE TEMPORARY ROOFING AS REQUIRED TO PROTECT BUILDING FROM DAMAGE.
5. CONTRACTOR TO ASSUME ALL CONCRETE INDICATED TO BE REMOVED IS REINFORCED.
6. IN LOCATION WHERE THE PLANS CALL FOR THE DEMOLITION OF THE EXISTING EXTERIOR BRICK VENEER, THE
CONTRACTOR SHALL DISMANTLE THE BRICK VENEER AND REMOVE ALL MORTAR FOR USE IN OTHER LOCATIONS FOR PATCHING. CONTRACTOR SHALL COORDINATE, WITH ARCHITECT, LOCATIONS WHERE RECYCLED BRICK ARE TO BE
USED FOR PATCHING.
7. AT LOCATIONS IN EXISTING FIRE WALLS WHERE SERVICES ARE REMOVED OR OPENINGS ARE CREATED, PATCH WALLS
TO MAINTAIN REQUIRED FIRE RATING.
8. REMOVE AND REPLACE ALL EXISTING VERTICAL AND HORIZONTAL EXTERIOR BRICK VENEER CONTROL JOINTS. SUBMIT
ACTUAL SEALANT JOINT COLOR SAMPLES TO THE GOVERNMENT FOR APPROVAL.
3/32" = 1'-0"A1.0
1 FIRST FLOOR DEMOLITION PLAN
Specific Demolition Notes:
REMOVE EXISTING WINDOWS AND PREPARE OPENINGS FOR
INFILL.
REMOVE EXISTING EXTERIOR METAL PANELS AND BRICK WORK
NECESSARY TO CONSTRUCT THE NEW ADDITION.
REMOVE EXISITNG SIDEWALK PAVEMENT NECESSARY TO
CONSTRUCT THE NEW ADDITION.
4 REMOVE EXISITNG DOWNSPOUT AND SEGMENTS OF GUTTER
REQUIRED TO TIE INTO THE NEW ADDTION GUTTERS.
5 REMOVE EXISTING WINDOW ASSEMBLY AND WALL BELOW
WINDOW AS REQUIRED TO INSTALL NEW DOOR ASSEMBLY.
REFER TO FLOOR PLAN.
6 EXISTING DOWNSPOUT TO REMAIN.
7 EXISTING SIDEWALK TO REMAIN
A5.1
A5.1
Sim
A5.1
Sim
A5.2
13' - 4"
34' - 8"
0' - 8"0' - 8"
A5.2
408 SF
STORAGE
30-16
1 1113
4 4
METAL WALL PANELS
BRICK VENEER
A5.1
Sim
A5.1
Sim
A5.2
A3.2
METAL WALL PANELS
BRICK VENEER
A5.1
Sim
METAL WALL PANELS
BRICK VENEER
GUARDRAIL (PAINT)
A5.2
A5.2
EXISTING STANDING SEAM METAL
ROOF TO REMAIN BEYOND
NEW TPO ROOFING MEMBRANE
A5.1
1/4" / 1'-0"
1/ 4"
1'
-0
A5.1
DS
DSDS
DS
1/4" / 1'-0"
NEW TPO ROOFING
MEMBRANE
EXISTING STANDING SEAM METAL ROOF TO REMAIN
1"
1' -0
EX
IS
TI
N G
S
LO
PE
:1
FI
EL
D
V
ER
IF
Y
HI
P
RI
DG
E HIP RIDGE
GUTTER
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A2.1
PLANS &
ELEVATIONS
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
1/4" = 1'-0"A2.1
1 FIRST FLOOR
1/4" = 1'-0"A2.1
2 NORTHWEST ELEVATION
1/4" = 1'-0"A2.1
3 SOUTHEAST ELEVATION
1/4" = 1'-0"A2.1
4 SOUTHWEST ELEVATION
1/4" = 1'-0"A2.1
5 ROOF PLAN
Specific Notes:
INFILL EXISTING OPENINGS WITH NEW METAL STUD
FRAMING AND BATT INSULATION. PROVIDE NEW
GYPSUM BOARD ON THE INTERIOR SIDE OF THE
EXISTING BUILDING SIDE AND REPAINT FULL
EXTENTS OF THE WALL.
CONNECT EXISTING GUTTER TO NEW ADDITION
GUTTER.
SET THRESHOLD IN FULL BED OF SEALANT3
CONCRETE SPLASH BLOCK4
AS SCHEDULED
DOOR WIDTH
A S S
C H
ED
U
LE
D
D O
O R
H
EI
G H T
F HM EXT
INSULATED FLUSH
HOLLOW METAL
DOOR (PNT-2)
HM F2 EXT
INSULATED HOLLOW
METAL FRAME 4"
HEAD (PNT-2)
0' - 2"
AS SCHEDULED
DOOR WIDTH 0' - 2"
A S S
C H
ED
U
LE
D
D O
O R
H
EI
G H T
HM F1 EXT
INSULATED HOLLOW
METAL FRAME 2"
HEAD (PNT-2)
0' - 2"
AS SCHEDULED
DOOR WIDTH 0' - 2"
A S S
C H
ED
U
LE
D
D O
O R
H
EI
G H T
1.) ALL WALL PAINT TO EXTEND TO DECK WHEN CEILING IS EXPOSED. PAINT EVERYTHING EXPOSED TO VIEW INCLUDING BUT NOT LIMITED TO
FIRE PROTECTION, STRUCTURAL, MECHANICAL, ELECTRICAL.
GENERAL NOTES:
CONTINUOUS CLEAT
METAL FLASHING
CONT. BACKER ROD & SEALANT,
TYP. BOTH SIDES - 3/8" MIN.
HOLLOW METAL DOOR/FRAME -
GROUT FILL - SEE DOOR SCHEDULE
HEAD DETAIL
BRICK
RIGID INSULATION
DAMPPROOFING
CMU
MASONRY RETURN AS REQ.
CONTINUOUS BACKER ROD & SEALANT
3/8" MIN. (BOTH SIDES)
JAMB DETAIL
VERIFY
AIR SPACE
METAL PANEL CLOSURE TRIM
CONT. BACKER ROD & SEALANT,
TYP. BOTH SIDES - 3/8" MIN.
P.T. WOOD BLOCKING
DAMPPROOFING
METAL WALL PANEL
STEEL BEAM- SEE STRUCTURAL
SHEATHING
METAL STUD FRAMING
STEEL ANGLE - SEE STRUCTURAL
METAL ROOF DECK
HOLLOW METAL DOOR/FRAME -
GROUT FILL - SEE DOOR SCHEDULE
CMU BEYOND
ROOF INSULATION
SEE DOOR SCHEDULE
HOLLOW METAL FRAME BEYOND
ALUMINIUM THRESHOLD SET IN
FULL BED OF SEALANT
SEAL - SEE HARDWARE SCHEDULE
PEJ
DAMPPROOFING
TERMINATION BAR & SEALANT
CMU
ZEE GIRT
HEAD TRIM
METAL DRIP WITH HEMMED EDGE
CONT. BACKER ROD & SEALANT,
TYP. BOTH SIDES - 3/8" MIN.
HOLLOW METAL FRAME -
SEE DOOR SCHEDULE
FILL WITH GROUT
SEE DOOR SCHEDULE
CMU BOND BEAM, SEE
STRUCTURAL FOR SIZE AND CELL
REINFORCEMENT REQUIREMENTS
WALL FLASHING
METAL WALL PANEL SYSTEM
METAL WALL PANEL
RIGID INSULATION
DAMPPROOFING
CMU
JAMB TRIM
HOLLOW METAL FRAME -
SEE DOOR SCHEDULE
FILL WITH GROUT
SEE DOOR SCHEDULE
LINE OF THRESHOLD
BEYOND
CONTINUOUS BACKER ROD &
SEALANT, 3/8" MIN. (BOTH
SIDES)
MASONRY "T" ANCHOR, SEE
SPECIFICATIONS FOR SPACING
REQUIREMENTS
JAMB DETAIL (METAL)
BRICK
AIR SPACE
RIGID INSULATION
DAMPPROOFING
CMU
MASONRY RETURN AS REQ.
HOLLOW METAL FRAME -
SEE DOOR SCHEDULE
FILL WITH GROUT
SEE DOOR SCHEDULE
LINE OF THRESHOLD
BEYOND
CONTINUOUS BACKER ROD &
SEALANT, 3/8" MIN. (BOTH
SIDES)
MASONRY "T" ANCHOR, SEE
SPECIFICATIONS FOR SPACING
REQUIREMENTS
JAMB DETAIL (BRICK)
ZEE GIRT
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A3.2
DOOR & FINISH
SCHEDULES
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
DOOR, OPENING & FRAME SCHEDULE
DOOR DETAILS
FIRE
RATING
GLAZING
TYPE NOTES
DOOR
NO. LEAVES
TOTAL
WIDTH HEIGHT THICKNESS TYPE
FRAME
TYPE
HEAD
DETAIL
JAMB
DETAIL
SILL
DETAIL
LIFE SAFETY PLAN
101 1 3' - 0" 7' - 0" 0' - 1 3/4" F HM EXT HM F2 EXT 1/A3.2 2/A3.2 3/A3.2
102 2 9' - 8" 8' - 11 1/2" 0' - 1 3/4" F HM EXT HM F1 EXT 4/A3.2 4/A3.2 3/A3.2
103 1 3' - 0" 7' - 0" 0' - 1 3/4" F HM EXT HM F2 EXT INSTALL NEW DOOR IN EXISTING WINDOW OPENING
3" = 1'-0"A3.2
4 OVERHEAD COILING DOOR - MASONRY ON CMU
3" = 1'-0"A3.2
3 HM FRAME SILL DETAIL
FINISH SCHEDULE
NO. ROOM NAME
FLOOR WALL
CEILING FINISH
DOORS
NOTESFINISH
BASE
FINISH
FINISH
FINISH
CASING
& TRIMNORTH WALL EAST WALL
SOUTH
WALL WEST WALL
LIFE SAFETY PLAN
30-16 STORAGE SC PNT-1 PNT-1 PNT-1 PNT-1 EXPOSED/PNT-3 PNT-2 PNT-2
Rev. Description Date
3" = 1'-0"A3.2
1 HM FRAME HEAD DETAIL
3" = 1'-0"A3.2
2 HM FRAME JAMB DETAIL
FINISH LEGEND:
SC - SEALED CONCRETE - REFER TO SPECIFICATION
SECTION 09 9123
PNT- # - INTERIOR PAINT - REFER TO SPECIFICATION
SECTION 09 9123. # - INDICATES INDEPENDENT
COLOR AS SELECTED BY CONTRACTING OFFICER
REPRESENTATIVE
NEW CMU - SEE
STRUCTURAL
EXISTING INSULATION
(REPLACE WHERE DAMAGED)
NEW SLAB FLOORING
NEW POROUS FILL
NEW FOOTING - SEE STRUCTURAL
PEJ
EXISITNG BRICK WAINSCOAT TO BE
REMOVED
EXISITNG ROOF EDGE TO BE REMOVED AS REQUIRED TO
INSTALL NEW ROOFING SYSTEMS
STEEL GUTTER SUPPORT OT
BE REMOVED
EXISTING METAL PANEL WALL
SYSTEM TO BE REMOVED
5/8" FIBERGLASS REINFORCED
GYPSUM SHEATING TO BE REMOVED
EXISTING GUTTER AND
DOWNSPOUTS TO BE
REMOVED
EXISTING METAL PANEL WALL
SYSTEM TO BE REMOVED
METAL FLASHING TO BE REMOVED
CMU - SEE STRUCTURAL
CONCRETE FOOTING - SEE
STRUCTURAL
TAPERED INSULATION
RIGID INSULATION (THICKNESS AS REQ.
TO MATCH EXISTING ROOF EDGE HEIGHT)
METAL DECKING
METAL FRAMING - SEE STRUCTURAL
TPO MEMBRANE
STANDARD BRICK
CMU - SEE STRUCTURAL
GROUT FILL
MATCH
EXISTING
9' - 4"
S
EE
S
TR
U C
TU
R A L
A5.1 7 Sim
A5.1 6 Sim
A5.1 5 Sim
Z CLIP
AIR SPACE
RIGID INSULATION
DAMPPROOFING
CMU - SEE STRUCTURAL
POROUS FILL
VAPOR BARRIER
CONCRETE SLAB - SEE STRUCTURAL
METAL WALL PANEL
RIGID INSULATION
DAMPPROOFING
CMU - SEE STRUCTURAL
TAPERED RIGID INSULATION
RIGID INSULATION (THICKNESS
AS REQ. TO MATCH EXISTING
ROOF EDGE HEIGHT)
METAL DECKING
METAL FRAMING - SEE
STRUCTURAL
TPO MEMBRANE
FLASHING WITH SEALANT
TERMINATION BAR
EXISTING METAL ROOFING PANEL - CUT AS REQUIRED TO INSTALL NEW ROOF SYSTEM
NEW METAL STUD FRAMING
BETWEN PURLINS AS REQUIRED
TO SUPPORT NEW PLYWOOD.
FILL WITH VINYL FACED BATT
INSULATION
NEW 3/4: T& G PLYWOOD SHEATHING
EXISITNG Z-PURLIN +/-
4'-0" UP SLOPE
EXISTING METAL BUILDING
RIGID FRAME
EXISTING GYPSUM WALLBOARD
9' - 4"
TAPERED INSULATION
RIGID INSULATION (THICKNESS AS REQ. TO
MATCH EXISTING ROOF EDGE HEIGHT)
METAL DECKING- SEE STRUCTURAL
METAL FLASHING
STEEL ANGLE - SEE STRUCTURAL
GUTTER
GUTTER STRAP
@ 36" O.C.
P.T. BLOCKING
DAMPPROOFING
TPO MEMBRANE
Z CLIP
RIGID INSULATION
METAL PANEL
DOWNSPOUT
BOND BEAM - SEE STRUCTURAL
DAMPPROOFING
SHEATHING
METAL STUD FRAMING
METAL
FLASHING
MORTER NET
DAMPPROOFING
WEEP
METAL DRIP EDGE WITH
HEMMED EDGE - SET IN
SEALANT
FLEXIBLE FLASHING
RIGID INSULATION
TERMINATION BAR
WITH SEALANT
GROUT INFILL
STANDARD BRICK
DOWNSPOUT
Z CLIP
CMU
FLASHING
Z CLIP
3' - 6 5/8"
DAMPPROOFING
RIGID INSULATION
STANDARD BRICK
METAL FLASHING SET IN
FULL BED OF SEALANT
TERMINATION BAR
W/ SEALANT
METAL PANEL
DOWNSPOUT
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A5.1
DETAILS & WALL
SECTIONS
G
LO
BA
L
A
SN
T
ST
O
RA
G E
F A
CI
LI
TY
Bi rm in gh am , A
L
21047 / BRKR 202911
February 2023
NV, NJ
DCD
1 1/2" = 1'-0"A5.1
4 NEW FOOTING CONNECTION
1 1/2" = 1'-0"A5.1
3 DEMOLITION WALL SECTION
1 1/2" = 1'-0"A5.1
1 NEW WALL SECTION
1 1/2" = 1'-0"A5.1
2 ROOF CONNECTION DETAIL
3" = 1'-0"A5.1
5 GUTTER DETAIL
3" = 1'-0"A5.1
7 FLASHING DETAIL
3" = 1'-0"A5.1
6 WATER TABLE DETAIL
1/4"x3"WIDE CONT.
WELD PLATE W/
1/2"Øx4" HEADED
STUDS @ 16"O.C.
CONT. HORIZ. MAS-
ONRY JOINT REINF.
@ 16"O.C., VERT.
CONT. U-BLOCK W/
#5 TOP & BOTTOM
#4 @ EA. JAMB & @
48"O.C., CENTERED. FILL
CELLS W/ CONC. FULL HT.
OF WALL ONLY @ #4.
1 1/2" STEEL DECK
8"
(+9'-4")
TOP OF
BLK.
5"x4"x12GA. BENT
PLATE CONT. (LLV)
8"x1 5/8"x12GA. 'C'-
JOISTS @ 16"O.C., MAX.
SEE ARCH. DWGS.
FOR FINISH
8"x1 5/8"x12GA. 'C'-
BLOCKING, CONT.
1/4"x3"WIDE CONT.
WELD PLATE W/
1/2"Øx4" HEADED
STUDS @ 16"O.C.
CONT. HORIZ. MAS-
ONRY JOINT REINF.
@ 16"O.C., VERT.
CONT. U-BLOCK W/
#5 TOP & BOTTOM
#4 @ EA. JAMB & @
48"O.C., CENTERED. FILL
CELLS W/ CONC. FULL HT.
OF WALL ONLY @ #4.
1 1/2" STEEL DECK
8"
(+9'-4")
TOP OF
BLK.
5"x4"x12GA. BENT
PLATE CONT. (LLV)
8"x1 5/8"x12GA. 'C'-OUTLOOKERS
@ 16"O.C., MAX.
8"x1 5/8"x12GA. 'C'-
JOISTS @ 16"O.C., MAX.
SEE ARCH. DWGS.
FOR FINISH
F .S
S
E E
P L A
N
TYPICAL FOOTING STEP DETAIL - (F.S.)
CONT. REINF.
MIN.
1' - 0"
CONT. REINF.
SEE SECTIONS FOR
TRANSVERSE REINF.
SAME SIZE & NUMBER
AS CONT. REINF.
TYP.
2' - 0"
M A
X
T Y
P
IC
A L S
C R
E W
S P
A C
IN
G
I N
T E
R
IO
R S
U P
P O
R T
S
6" MAX. TYPICAL SCREW SPACING
@ CONT. STEEL SUPPORT
M A
X
T Y
P
IC
A L S
C R
E W
S P
A C
IN
G
E
N D
S U
P P
O R
T S
TYPICAL ROOF DECK FASTENING REQUIREMENTS
SIDE LAP
DECK
SUPPORT
SIDE LAP ATTACHMENT
W/ #10 SCREWS @ 6"O.C.
NO SCALE
2" LAP
DECK SHALL BE MIN. (3)SPAN CONTINUOUS
NOTE:
ALL SCREWS @ CONT. SUPPORTS SHALL BE #12 SELF-DRILLING
SELF-TAPPING SCREWS. AT BAR JOIST ROOFS, USE 5/8"Ø PUDDLE
WELDS (IN LIEU OF SCREWS) @ STEEL SUPPORTS.
TYPICAL SLAB CONSTRUCTION
W.W.F.
JOINT DETAIL-(C.J.)
ALTERNATE SLAB CONSTRUCTION
JOINT DETAIL (SAWED JOINT)
W.W.F.
SAW CUT 1/8"x1" DEEP
SAWED JOINT. FILL
JOINT W/ SEALANT.
NOTE:
IF SAWED JOINTS ARE USED,
JOINTS MUST BE SAWED
SAME DAY AS SLAB POUR.
WOOD FORMED
KEYED JOINT
/2
6" 6"
1. BEAR 8" HIGH U-BLOCKS 8" EACH END.
2. FILL CELLS W/ CONCRETE FULL HEIGHT @
U-BLOCK BEARING FOR ENTIRE LENGTH
OF BEARING & REINFORCE EACH CELL W/
BAR SAME SIZE AS WALL REINFORCING.
VERTICAL REINFORCING SHALL BE
CONTINUOUS THRU LINTEL @ BEARING.
3. FILL CELLS OF U-BLOCK LINTEL TO FULL
HEIGHT IN ONE POUR.
NOTES:
1/4"x3"WIDE CONT.
WELD PLATE W/
1/2"Øx4" HEADED
STUDS @ 16"O.C.
CONT. HORIZ. MAS-
ONRY JOINT REINF.
@ 16"O.C., VERT.
CONT. U-BLOCK W/
#5 TOP & BOTTOM
#4 @ 48"O.C., CENTERED. FILL CELLS
W/ CONC. FULL HT. OF
WALL ONLY @ #4.
1 1/2" STEEL DECK
6"
(+9'-4")
TOP OF
BLK.
3"x3"x12GA. BENT
PLATE CONT.
8"x1 5/8"x12GA. 'C'-
JOISTS @ 16"O.C., MAX.
8"x1 5/8"x12GA. 'C'-
BLOCKING, CONT.
EXISTING BUILDING
1" E.J.
LENGTH
SCH. PL. 1' - 4"
TYPICAL BEAM BEARING ON C.M.U. WALL DETAIL (PARALLEL)
END OF DOWELS
PROVIDE 2" LONG HORIZ.
SLOTTED HOLES IN BEAM &
PLATE. FINGER TIGHTEN
NUTS & UPSET THREADS.
CONT. U-BLOCK
W/ #5 TOP & BOT.
SEE PLAN FOR
BEAM SIZE
5/8"Ø SMOOTH DOWELS
WELDED TO BEAM
1/2"x7"x16" BEARING PLATE W/ (2)3/4"Øx14" HEADED
A.B.'S ON 1"± GROUT
FILL (2)CELLS (16") W/ CONC.
FULL HT. BELOW BEARING &
REINF. W/ 1-BAR SAME SIZE
AS WALL REINF. EA. CELL.
Sheet Number
Sheet Title
Project Title
M o n tg o m er y
D o th an
W W W .S S L A R C H .C O M
(M
D
Job Number
Date
Drawn By
Checked By
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
02-06-23
S0.1
General Notes-Schedules -Typical Details
G L
O B
A L
A S N
T S T
O R
A G
E F
A C
IL
IT
Y
B ir m in gh am
A
L
21047 / BRKR 202911
February 2023
R. Casey
JWD
3/4" = 1'-0"S0.1
1 SECTION
3/4" = 1'-0"S0.1
2 SECTION
Lintel Schedule Mark or Location Max. Span Type Size Reinforcing Remarks
8"C.M.U. 3'-4" U-BLOCK 8x8 #5 TOP & BOTTOM 8" HIGH U-BLOCK
3/4" = 1'-0"S0.1
3 SECTION
FOUNDATION:
1. THE BEARING STRATA OF ALL FOOTINGS AND GRADE BEAMS SHALL BE
INSPECTED AND APPROVED BY THE SOILS TESTING LABORATORY PRIOR
TO PLACING THE REINFORCING STEEL AND CONCRETE.
2. ALL FOOTINGS SHALL BEAR ON AN UNDISTURBED SOIL STRATA OR
COMPACTED FILL CAPABLE OF SUSTAINING THE LOADS.
3. FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING OF
P = 1500 PSF. THE TESTING AGENCY SHALL VERIFY THAT THE SOILS ARE
CAPABLE OF SUSTAINING 2000 PSF PRIOR TO CONCRETE PLACEMENT.
4. ELEVATIONS SHOWN ON PLAN ARE TOP OF FOOTINGS AND ARE MINIMUM
DEPTH. DIFFERENT OR UNUSUAL CONDITIONS SHALL BE REPORTED TO
THE GOVERNMENT.
5. ALL FOOTING REINFORCEMENT SHALL BE HELD SECURELY FROM THE
GROUND. CONCRETE BLOCK AND BROKEN TILE SHALL NOT BE USED.
CONCRETE OR CLAY BRICK MAY BE USED.
6. DOWEL ALL FOOTINGS AND WALLS WHERE THEY ABUT WITH SAME STEEL
AS VERTICAL.
7. PROVIDE PREFORMED EXPANSION JOINT WHERE SHOWN.
8. IN FOOTINGS PROVIDE CORNER BARS AT ALL EXTERIOR BUILDING CORNERS.
9. DO NOT BACK FILL BEHIND FOUNDATION WALLS UNTIL TOP AND BOTTOM
SLABS HAVE BEEN POURED AND ATTAINED THEIR DESIGN STRENGTHS.
10. BACK FILL BOTH SIDES OF FOUNDATION WALLS AT SAME TIME TO
PREVENT OVERTURNING.
11. BACK FILL BEHIND ALL RETAINING WALLS AND BASEMENT WALLS SHALL
BE AN APPROVED GRANULAR MATERIAL.
CONCRETE:
1. ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH AT 28 DAYS OF
F'c = 3000 PSI AND A MAXIMUM WATER-CEMENT RATIO OF 0.53.
ALL CONCRETE FOR EXTERIOR APPLICATIONS SHALL CONTAIN
ENTRAINED AIR. SEE SPECS FOR ADDITIONAL INFORMATION.
2. REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60.
3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
4. UNLESS NOTED OTHERWISE PROTECTIVE COVERING OF REINFORCEMENT
SHALL BE AS FOLLOWS ( SEE DETAILS ) : FOOTINGS AND GRADE BEAMS
3" CLEAR BOTTOM AND SIDES, 1 1/2" CLEAR TOP. CONCRETE SLABS
3/4" CLEAR. WALLS 1 1/2" CLEAR SIDES. BEAMS 1 1/2" CLEAR TO
STIRRUPS. CONCRETE COLUMNS 1 1/2" CLEAR TO TIES.
5. LAP ALL CONCRETE WALL VERTICAL REINFORCING AND CONCRETE BEAM
HORIZONTAL REINFORCING WITH CLASS B LAP SPLICES. LAP ALL OTHER
CONTINUOUS BARS WITH CLASS A SPLICES UNLESS NOTED OTHERWISE.
6. PLACING PLANS AND DETAILS SHALL BE IN ACCORDANCE WITH THE
LATEST "A.C.I. DETAILING MANUAL".
7. STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR THE GOVERNMENT'S
REVIEW.
8. DO NOT RUN CONDUITS, RACEWAYS, OR PIPES IN CONCRETE SLABS, BEAMS,
OR COLUMNS WITHOUT SPECIFIC APPROVAL FROM BLACKBURN DANIELS O'BARR.
MASONRY:
1. PROVIDE MASONRY HORIZONTAL JOINT REINFORCEMENT 16" O.C.
VERTICAL IN ALL CONCRETE BLOCK WALLS. REINFORCEMENT SHALL BE
FOR TOTAL WIDTH OF CAVITY WALLS.
2. WHERE CONCRETE OR STEEL BEAMS BEAR ON CONCRETE BLOCK WALLS, BLOCK
CELLS SHALL BE FILLED WITH CONCRETE 1'-4" WIDE TO FOUNDATION AND
REINFORCED WITH A #5 EACH CELL UNLESS NOTED OR DETAILED OTHERWISE.
3. CONCRETE OR GROUT FOR BLOCK FILL SHALL HAVE 3/8 INCH MAXIMUM
SIZE COARSE AGGREGATE AND SUFFICIENT WATER SO THE CONCRETE
WILL FLOW INTO THE BLOCK CELLS WITHOUT LEAVING VOIDS. HEIGHT
OF LIFT WHEN FILLING CELLS SHALL NOT EXCEED 4'-0".
4. CONCRETE OR GROUT FILL FOR C.M.U. SHALL HAVE A 28 DAY COMPRESSIVE
STRENGTH OF F'c = 3000 PSI. ON 16" AND DEEPER U-BLOCKS, FILL
CELLS FULL HEIGHT OF LINTEL AT SAME TIME.
5. ANCHOR ALL MASONRY WALLS TO STEEL COLUMNS WITH STRAP ANCHORS
AT 16" O.C. VERTICALLY UNLESS SHOWN OTHERWISE.
6. UNLESS INDICATED OTHERWISE PROVIDE KEYED RUBBER MASONRY
CONTROL JOINTS AT A MAXIMUM SPACING OF 25'-4". JOINT SHALL
BE DISCONTINUOUS AT BOND BEAM.
7. PROVIDE REINFORCING BAR SUPPORTS TO CENTER VERTICAL
REINFORCING IN MASONRY WALLS.
8. PROVIDE 48 DIAMETER LAP SPLICE IN VERTICAL MASONRY REINFORCING.
9. PROVIDE CORNER BARS IN U-BLOCK BOND BEAMS AT CORNERS, TYPICAL.
10. ALL CMU SHALL BE PLACED IN A RUNNING BOND PATTERN UNLESS NOTED
OTHERWISE.
11. VERTICAL REINFORCING SHALL BE CONTINUOUS THROUGH BOND BEAMS AND
LINTELS (CUT OUT OR NOTCH BOTTOM OF U-BLOCKS AS REQUIRED -- DO NOT
SUBSTITUTE BLOCK WITH KNOCK-OUT WEBS WHERE STANDARD U-BLOCK IS
INDICATED). FOR BOND BEAMS AT TOP OF WALL, EXTEND VERTICAL
REINFORCING TO 1" CLEAR TOP OF BOND BEAM.
12. ALL CMU DOWELS SHALL BE SAME SIZE AND SPACING AS THE
VERTICAL REINFORCEMENT.
STRUCTURAL STEEL:
1. ALL STRUCTURAL STEEL W AND WT SHAPES SHALL CONFORM TO ASTM
A992 (GRADE 50). OTHER SHAPES SHALL CONFORM TO ASTM, A36,
LATEST EDITION (EXCEPT STEEL JOISTS AND TUBE SECTIONS).
2. STRUCTURAL STEEL TUBE SECTIONS SHALL CONFORM TO ASTM A500,
GRADE B, Fy = 46.0 KSI.
3. HEADED STUDS SHALL BE TYPE B SHEAR CONNECTORS (Fu = 65 KSI).
4. STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR THE GOVERNMENT'S
REVIEW.
5. THE CONTRACTOR SHALL VERIFY ALL SH0P DRAWINGS DIMENSIONS WITH
STRUCTURAL AND ARCHITECTURAL PLANS AND DETAILS.
6. BOLTED CONNECTIONS SHALL BE MADE WITH HIGH STRENGTH BOLTS
CONFORMING TO ASTM A325. USE 3/4 INCH DIAMETER MINIMUM.
UNLESS NOTED OTHERWISE, ALL BOLTS SHALL BE TIGHTENED AS FULLY
PRETENSIONED BEARING CONNECTIONS.
STRUCTURAL STEEL CONTINUED:
7. CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED
BY THE FABRICATOR. WHERE POSSIBLE USE DOUBLE ANGLE
CONNECTIONS. USE MAXIMUM NUMBER OF BOLTS FOR DEPTH
OF BEAM WITH SINGLE ROW OF BOLTS. WHERE DOUBLE ANGLE
CONNECTIONS ARE NOT POSSIBLE, FABRICATOR SHALL DESIGN
CONNECTION FOR CAPACITY EQUIVALENT TO DBL-ANGLE CONNECTION
WITH MAX NO. BOLTS UNLESS DETAILED OTHERWISE.
8. FOR DBL-ANGLE CONNECTIONS, MIN ANGLE THICKNESS SHALL BE 5/16"
FOR 3/4 INCH DIAMETER BOLTS AND 3/8" FOR 7/8 INCH DIAMETER BOLTS
AND LARGER.
9. UNLESS SHOWN OTHERWISE PROVIDE 1/2 X 7 1/2 X 7 1/2 BEARING
PLATES ON 1 INCH GROUT WITH 2-3/4" DIAMETER ANCHOR BOLTS
UNDER ALL STEEL BEAMS THAT BEAR ON MASONRY WALLS.
10. ANY MEMBER CALLED OUT TO BE BENT TO RADIUS SHALL BE FABRICATED OUT
OF PLATE WITH EQUIVALENT SECTION PROPERTIES IF BENDING TO RADIUS
IS IMPRACTCAL.
COLD-FORMED STEEL STUDS:
1. PROVIDE COLD FORMED STEEL STUDS WHERE INDICATED ON THE PLAN.
ALL SIZES AND GAGES SHOWN SHALL BE CONSIDERED MINIMUM.
2. LIGHT STEEL GALVANIZED (G-60) METAL STUDS, OF SIZES SHOWN
COMPLETE WITH ALL ACCESSORIES REQUIRED. 16 GA AND HEAVIER
MEMBERS SHALL MEET ASTM A-1003/A1003M, GRADE D WITH 50 KSI
YIELD.
3. PROVIDE SHOP DRAWINGS PREPARED BY COLD FORMED METAL FRAMING
MANUFACTURER. SUBMIT FOR APPROVAL SHOWING PLANS, SECTIONS,
ELEVATIONS, LAYOUTS, PROFILES, PRODUCT COMPONENTS, AND INDICATING
SPACING OF MEMBERS, PROPOSED METHODS OF FRAMING LINTELS,
DOORWAY FRAMING, ETC. SHOW CONNECTION DETAILS WITH SCREW TYPE
AND LOCATIONS AND ALL OTHER FASTENER REQUIREMENTS. INCLUDE
CATALOG DATA ON ALL PRODUCT MATERIAL.
4. MANUFACTURER SHALL SUBMIT SHOP DRAWINGS AND DESIGN CAL-
CULATIONS INCLUDING ALL CONNNECTIONS. DESIGNS SHALL BE SIGNED
BY A REGISTERED PROFESSIONAL ENGINEER, REGISTERED IN THE
STATE OF ALABAMA.
BUILDING CANOPIES:
1. THE COMPLETE DESIGN OF THE CANOPIES INCLUDING ALL
COMPONENTS SHOWN OR NOT SHOWN ON THE DRAWINGS SHALL BE
ACCOMPLISHED BY THE CANOPY MANUFACTURER.
2. THE DESIGN SHALL BE MADE BY A REGISTERED ENGINEER, REGISTERED
IN THE STATE OF ALABAMA AND HE SHALL AFFIX HIS REGISTRATION
NUMBER TO ALL SHOP DRAWINGS AND CALCULATIONS.
CODES:
ALL PARTS SHALL BE FURNISHED AND ERECTED ACCORDING TO THE
APPLICABLE CODES AND SPECIFICATIONS OF THE FOLLOWING:
AMERICAN CONCRETE INSTITUTE (ACI)
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
AMERICAN WELDING SOCIETY (AWS)
OSHA STEEL ERECTION STANDARD (OSHA)
INTERNATIONAL BUILDING CODE (IBC 2015) (ICC)
DESIGN LIVE LOADS:
ROOF.......20 PSF.
OFFICES
RISK CATEGORY (PER IBC 2015/ASCE 7-10)..........III
WIND.......INTERNATIONAL BUILDING CODE (PER ASCE 7-10)
ULTIMATE DESIGN WIND SPEED (Vult).........120 MPH NOMINAL DESIGN WIND SPEED (Vasd)..........93 MPH
WIND EXPOSURE.............................C
INTERNAL PRESSURE COEFFICIENTS............+/-0.18
COMPONENTS AND CLADDING ULTIMATE WIND PRESSURES:
NOTE: MULTIPLY ALL VALUES SHOWN BELOW BY 0.6 TO GET ALLOWABLE DESIGN PRESSURES.
ROOF:TRIBUTARY AREA A = 10 SF
ZONE 1: -49.7PSF/31.3PSF
ZONE 2: -86.5PSF/31.3PSF
ZONE 3: -128.0PSF/31.3PSF
WALL:TRIBUTARY AREA A = 10 SF
ZONE 4: -58.9PSF/54.3PSF
ZONE 5: -72.7PSF/54.3PSF
CORNER ZONE = 7.5 FT
SEISMIC....INTERNATIONAL BUILDING CODE (PER ASCE 7-10)
SEISMIC IMPORTANCE FACTOR.................Ie=1.25 MAPPED SPECTRAL ACCELERATION (SHORT-TERM).Ss=0.256
MAPPED SPECTRAL ACCELERATION (1-SECOND)...S1=0.105
SITE CLASS................................D
SHORT-PERIOD SPECTRAL RESPONSE ACCEL......Sds=0.281g 1-SECOND SPECTRAL RESPONSE ACCEL..........Sd1=0.167g
SEISMIC DESIGN CATEGORY...................C
SEISMIC FORCE-RESISTING SYSTEM............CMU SHEAR WALLS
DESIGN BASE SHEAR (ULTIMATE)..............3k SEISMIC RESPONSE COEFFICIENT..............Cs=0.064
RESPONSE MODIFICATION FACTOR..............R=2
ANALYSIS PROCEDURE........................ASCE 7 (SECT 12.8)
SNOW.......INTERNATIONAL BUILDING CODE
GROUND SNOW LOAD..........................Pg=5 PSF
SPECIAL INSPECTIONS
1. ALL SPECIAL INSPECTIONS REQUIRED BY CHAPTER 17 OF THE IBC 2015 SHALL BE
PERFORMED BY A DESIGNATED TESTING EGENCY OR AGENCIES RESPONSIBLE
FOR SPECIAL INSPECTIONS.
GENERAL NOTES
36' - 0"
1' - 4" 1' - 4"
E .J
C.J.
C .J
S1.1
S1.1 2
S1.1
S1.1
8" F.S.
16" F.S. 24" F.S.
T.O.F. EL.= +612'-1"
T.O.F. EL.= +610'-1"
T.O.F. EL.= +610'-1"
T.O.F. EL.= +612'-1"
NEW RETAINING
WALL. SEE CIVIL
DRAWINGS
T.O.F. EL.= +610'-9"
C .J
C .J
36' - 0"
1' - 4" 1' - 4"
E .J
S0.1
S0.1
S1.1
S0.1
8"x1 5/8"x12GA. "C" JOISTS @ 16"O.C., MAX.
W x1
8" 8"
2' - 0"
1' - 4"
SEE PLAN
FOR EL.
FILL ALL CELLS W/ CONC.
BELOW FIN. FLOOR
FIN. FLOOR
(2)#5 CONT. TOP &
BOT. W/ #4 @ 24"O.C.
6x6-W1.4xW1.4 W.W.F.
+0'-0"
#4 @ EA. JAMB & @ 48"O.C.,
CENTERED. FILL CELLS
SOLID W/ CONC. FULL HT.
OF WALL ONLY @ #4.
CONT. HORIZ. MAS-
ONRY JOINT REINF.
@ 16"O.C., VERT.
FILL CAVITY W/ CONC.
BELOW FIN. GRADE
FIN. GRADE. SEE
CIVIL DWGS.
PROVIDE 3/8" PEJ. W/
SEALANT WHERE
CONC. ABUTS WALL
CONT. HEADER BLOCK
S P
L
IC
E
D
IA
4"4"
SEE ARCH. DWGS.
FOR FINISH
#4 @ 24"O.C. BELOW
FIN. FLOOR SLAB
FIN. FLOOR
6x6-W1.4xW1.4 W.W.F.
+0'-0"
SLOPE
3/8" PEJ. W/ SEALANT
JAMB BEYOND
L2x2x1/4 CONT. W/ 3/8"Ø HEADED
STUD ANCHORS @ 24"O.C.
COORDINATE W/
ROLL-UP DOOR MFR.
2' - 0"
5" 1' - 2" 5"
SEE PLAN
FOR EL.
FILL ALL CELLS W/ CONC.
BELOW FIN. FLOOR
(2)#5 CONT. TOP &
BOT. W/ #4 @ 24"O.C.
S P
L
IC
E
D
IA
1" E.J. 6"
1' - 4"
4" MIN. 1' - 0"
FIN. FLOOR
+0'-0"
F
IE
L D
V E
R
IF
Y
C O
N T
R A
C T
O R
CONT. HORIZ. MAS-
ONRY JOINT REINF.
@ 16"O.C., VERT.
EXIST.
WALL &
FTG. TO
REMAIN
FILL ALL CELLS
W/ CONC. BELOW
FIN. FLOOR
(2)#5 CONT.
W/ #3 TIES @
16"O.C.
(2)#5 CONT. T.&B. W/
#3 TIES @ 16"O.C.
#4 @ 24"O.C. EPOXY
GROUT INTO EXIST.
FOOTING
#4 @ 48"O.C., CENTERED. FILL
CELLS SOLID W/ CONC. FULL
HT. OF WALL ONLY @ #4.
3/8" PEJ W/ SEALANT
6x6-W1.4xW1.4 W.W.F.
1 1/2" STEEL DECK
(+9'-4")
TOP OF
BLK.
5"x5"x12GA. BENT
PLATE CONT.
8"x1 5/8"x12GA. 'C'-OUTLOOKERS
@ 16"O.C., MAX.
8"x1 5/8"x12GA. 'C'-JOISTS
@ 16"O.C., MAX.
SEE ARCH. DWGS.
FOR FINISH
JAMB BEYOND
12GA. CLIP EA.
OUTLOOKER
W8
4"
Sheet Number
Sheet Title
Project Title
M o n tg o m er y
D o th an
W W W .S S L A R C H .C O M
(M
D
Job Number
Date
Drawn By
Checked By
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
02-06-23
S1.1
FRAMING PLANS -
SECTIONS &
DETAILS
G L
O B
A L
A S N
T S T
O R
A G
E F
A C
IL
IT
Y
B ir m in gh am
A
L
21047 / BRKR 202911
February 2023
R. Casey
JWD
1/4" = 1'-0"
FOUNDATION PLAN
1/4" = 1'-0"
ROOF FRAMING PLAN
3/4" = 1'-0"S1.1
1 SECTION
3/4" = 1'-0"S1.1
2 SECTION
4" THICK CONCRETE SLAB W/ 6x6-W1.4x
W1.4 W.W.F. OVER VAPOR BARRIER
OVER 4" POROUS FILL.
FINISH FLOOR EL.+615'-5" (+0'-0")
FLOOR CONSTRUCTION
1 1/2" DEEP, 22 GAGE, WIDE RIB
STEEL DECK W/ THE FOLLOWING
MINIMUM SECTION PROPERTIES PER
FOOT OF WIDTH:
S=0.19 IN.3 I+=0.16 IN.4 I-=0.18 IN.4
ROOF CONSTRUCTION
3/4" = 1'-0"S1.1
3 SECTION
3/4" = 1'-0"S1.1
4 SECTION
Sheet Number
Sheet Title
Project Title
Job Number
Date
Drawn By
Checked By
G L
O B
A L
A S N
T
S T
O R
A G
E F
A C
IL
IT
Y
B ir m in gh am
A
L
21047 / BRKR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .