Bldg 2215.pdf

PDF 759 KB Posted

Attached to
Auditorium Audio/Visual Refresh Sources Sought
Solicitation number
FA489723SS051
Issued by

About this file

This document contains architectural drawings for Building 2215 at Mountain Home Air Force Base. The drawings show an overall floor plan and key for the building, indicating new and existing items. Modifications include relocating and securing existing seating to the floor, and installing new seating to match the existing design and color. Mechanical, electrical, and demolition details can be found in other referenced drawings.

The related federal contract opportunity is a sources sought notice for an auditorium audio/visual refresh at an Air Combat Command base. The solicitation number and details provided indicate the Air Force is gathering market research on potential contractors that can provide products or services to upgrade the audio/visual systems in an auditorium at Mountain Home Air Force Base.

View the file

Other files

File Type Posted
SPECS-OSS Auditorium AV system refresh.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D e s ig n e d b y

C h e ck e d b y

D ra w n b y

C a d F il e

D a te

P ro je ct

C H

M H

IL

L

S y m b o l

A p p ro v D a te

D e s c ri p ti o n

Drawing Number:

A B C D E F G H

GUNFIGHTERS

HOME OF THE

COMBAT COMMAND

AIR

DEPARTMENT OF

MOUNTAIN HOME AFB.

THE AIR FORCE

MOUNTAIN HOME

AFB

U.S. AIR FORCE

366 CES/CECD

1030 LIBERATOR ST.

MOUNTAIN HOME AFB, ID

83648-5442

E a s t F ro n t S tr e et

S u it e

5A -1

0.

d g n

S p e c

P ro je ct

B o is e I d a h o

2-

FILENAME: PLOT DATE: PLOT TIME:2019\04\24 1:58:48 PM

SHEET of

/2

/2

F A

C

IL

IT

Y

KEY PLAN

N

PLAN TRUE

N

A C

B D

Q Y Z

H

-8

R E P

A

IR

S

Q U

A D O

P S

C E

R T

IF

IE

D F

IN

A L D

E S

IG

N

S U

P P L

Y

VEST

OFFICE

VAULT

CRYPTO

OFFICE

EXEC

OSS CC

UFC

SEC ADMINADMIN

BRF

WCCS AREA

VAULT

SECURE

VEST

OPER

COMP

MUNS

AFE

CHEM

HAZ

BENC

AFE

MAIN SHOP

AFE

MAIN SHOP

AFE

C O

R R

ID

O R

CORRIDORCORRIDOR

C O

R R

ID

O R

C O

R R

ID

O R

C O

R R

ID

O R

C O

R R

ID

O R

WALKWAY

STORAGE

AFE

AUDITORIUM

C O

R R

ID

O R

C O

R R

ID

O R

ROOM

MECHANICAL

ROOM

MECHANICAL

ROOM

ELECTRICAL

ROOM

MECHANICAL

STORAGE

SERE

FLT CHF

AFE

SUPT

AFE

SAD

COMMON AREA

INTEL

PLANNING

INTEL

OSK

ROOM

MOM

MEN

WOMEN

JAN

VEST

ROOM

CONFERENCE

GLO

OFC

GLO

SGT

1STUMP

PLN

MSN

STOR

ADMIN

DO

COMM

SUPT

SQ

TRNG

SERE

TRNG

SERE

C O

R R

ID

O R

C O

R R

ID

O R

PHYSIO

AERO

HARMSERE

ROOM

CONFERENCE

MAIN

MAN

AERO

STOR

UDM

CONTROL

UDM

UDM

ROOM

CONFERENCE OPS

RANGE

WOMEN

JAN

OFFICE

C O

R R

ID

O R

VEST

CORRIDOR

103102

113 114 115

106 107

119 120

122 124

126125

2 174 175

176 178

185 186

188 189

170 171

C O

R R

ID

O R

FLT/CC

OSO

MGR

P5

CHAPLAIN

OSOTSCHED

AIR SPACE

SUPT

HARM

VEST

ROOM

HERITAGE

CVN 1

CVN 2 CVN 3

CVN 4

CVN 5

CVN 7

CVN 6

C V

N

ROOM 1

ROOM 2

CVN 10

C H

A S

E

ROOM 3

CVN 9

MEN

PARA ROOM

AFE

TRAINING

AFE

A

B

2 3 4

C

D

682783

A-110

KEYED NOTES

GENERAL NOTES

X

1/16"=1'-0"

OVERALL FLOOR PLAN

O V E

R A

L L F

L O

O R P

L A

N

J R

E S

E

IG

H

D D

A L S

O G

L

IO

A R

C H

IT

E C

T U

R A

L

LEGEND:

EXISTING ITEMS TO REMAIN

NEW OR MODIFIED ITEMS

682783_2215A-110.dgn

L

IN

E

M A

T C

H

A -1

A -1

LINE

MATCH

A-111

A-112

L

IN

E

M A

T C

H

A -1

A -1

LINE

MATCH

A-113

A-114

DETAILED INFORMATION

OF NEW WORK, SEE A-111, A-112, A-113, AND A-114 FOR

THIS PLAN IS INTENDED TO GIVE AND OVERALL LAYOUT B.

FOR ADDITIONAL INFORMATION

REFER TO ELECTRICAL AND MECHANICAL DEMOLITION A.

6'-8"

26'-6" 28'-8"

48" MIN.

EQUAL

48" MIN.

EQUAL

24 149

C F

IL

A N

O W

IC

Z

30'-0"

INDICATED, SEE 10/A-503 FOR TYPICAL LAYOUT

SECURE TO THE FLOOR IN THE CONFIGURATION

NEW SEATING TO MATCH EXISTING DESIGN AND COLOR, 2.

FOR TYPICAL LAYOUT

FLOOR IN THE CONFIGURATION INDICATED, SEE 10/A-503

EXISTING SEATING, RELOCATE AND SECURE TO THE 1.

LICENSED

A RCHITECT

STA TE OF IDAHO

A R-916427

JO HN P. RESEIG H

25Apr 2019

File details come from the government source that posted it. Updated .