This is a bid specification document from the City of Minneapolis Public Works for the procurement of trailer-mounted high flow dewatering pumps. The City is seeking bids from qualified suppliers to furnish and deliver two trailer-mounted, diesel-driven, automatic self-priming centrifugal pump packages suitable for construction dewatering, municipal bypass pumping, industrial applications, mining operations, and emergency pumping services. One unit shall include an open-canopy enclosure, and the other shall include a sound-attenuated, closed-canopy enclosure. Bidders must submit a single lump sum bid to furnish and deliver both dewatering pumps. A single purchase order will be awarded to the overall low, responsive, responsible bidder meeting all specifications. The City requests delivery of one pump by December 31, 2026, to the Water Treatment Facility at 4100 Marshall Street Northeast in Fridley, Minnesota, with deliveries accepted Monday through Friday from 7:30 AM to 3:00 PM (excluding federal holidays). Delivery must be coordinated with Shane Jasper at 612-661-4938 or Shane.Jasper@minneapolismn.gov prior to arrival.

The pumps must meet specific performance requirements including a maximum flow capacity of 2,400 to 2,800 GPM, maximum total dynamic head of 150 to 180 feet, and minimum peak pump efficiency of 75 percent. The pump package shall include an integrated fuel tank with minimum capacity of 80 gallons, a diesel engine meeting current U.S. EPA emissions requirements with power rating under 75 horsepower, local manual controls with automatic start/stop functionality, and engine monitoring and shutdown protection. Bidders must submit comprehensive documentation including pump performance curves, dimensional drawings, equipment weight, fuel consumption information, materials of construction lists, maintenance requirements, spare parts recommendations, and warranty information including a one-year parts and labor warranty covering all pump parts. The City reserves the right to reject any or all bids, waive informalities, and award the purchase order to the lowest responsive and responsible supplier. Payment will be rendered within thirty days of invoice submission and final inspection and acceptance of materials, with invoices submitted to City of Minneapolis Accounts Payable at 505 Fourth Avenue South, Room 310, Minneapolis, Minnesota 55415, or via email at submitinvoices@minneapolismn.gov.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATIONS

City of Minneapolis Public Works

Trailer-Mounted High Flow Dewatering Pumps

Event No.: 4397

OVERVIEW/PURPOSE

The City of Minneapolis is seeking bids from qualified suppliers to furnish and deliver two (2) trailer-mounted, diesel-driven, automatic self-priming centrifugal pump packages. The pumps shall be suitable for construction dewatering, municipal bypass pumping, industrial applications, mining operations, and emergency pumping services.

BASIS OF AWARD:

A single Purchase Order (PO) will be awarded to the (overall) low, responsive, responsible bidder meeting all specifications.

ITEM DESCRIPTIONS:

One (1) unit shall be provided with an open-canopy enclosure, and one (1) unit shall be provided with a sound-attenuated, closed-canopy enclosure. Both units shall comply with all specifications and documentation requirements outlined in this solicitation.

Bidders shall submit one (1) lump sum bid to furnish and deliver BOTH dewatering pumps. Detailed specifications for the “Trailer-Mounted Automatic Self-Priming Centrifugal Dewatering Pumps” are attached below.

NON-EXCLUSIVE:

Any PO(s) resulting from this Request for Bid will not be an exclusive agreement and the City reserves the right to hire other suppliers, to perform similar work, and seek bids from other vendors.

RIGHTS OF THE CITY:

The City reserves the right to reject all or any part of any bid, waive informalities, and award the PO to the lowest responsive and responsible suppliers to best serve the interest of the City. Informality shall mean a minor defect or variation of a bid from the exact requirements of the Request for Bid which does not affect the price, quality, quantity, or delivery schedule for the goods, services or construction being procured.

GENERAL REQUIREMENTS:

Bidders must demonstrate that they have the resources and capability to provide the materials as described herein. All bidders must submit the documentation indicated below with their bid. Failure to provide any of the required documentation shall be cause for bid to be deemed non-responsible and rejected.

QUALITY OF MATERIALS:

Unless otherwise specified, all materials and equipment incorporated in this project shall be new and of the best quality for the purpose intended. Should the quality of a material be unspecified in the documents, the Supplier must provide the best product for the purpose intended to the satisfaction of the City Project Manager.

DELIVERY INFORMATION:

If possible the City would like one (1) of the pumps delivered by 12/31/2026. Please deliver to:

WATER TREATMENT FACILITY

4100 Marshall Street Northeast Fridley, MN 55421

The facility accepts deliveries from 7:30 AM to 3:00 PM, Monday through Friday (except federal holidays).

Delivery date and time must be confirmed with Shane Jasper at 612-661-4938 or via email at Shane.Jasper@minneapolismn.gov prior to arrival.

INVOICE AND PAYMENT:

All work requested under this Contract shall be placed on a City issued Purchase Order. Bidder shall make all reasonable efforts to submit invoices and documentation in an electronic format, such as PDF or other format compatible with City software capabilities, in lieu of paper invoices and documentation, when so requested by City. Upon delivery and acceptance of the materials, the Bidder shall submit an invoice detailing the appropriate charges.

Invoices shall be submitted to:

City of Minneapolis – Accounts Payable 505 Fourth Ave. S, Room 310 Minneapolis, MN 55415 Email: submitinvoices@minneapolismn.gov

Upon receipt of invoice and final inspection and acceptance of the materials, the City will render payment within thirty (30) days unless any items thereon are questioned, in which event payment will be withheld pending verification of the amount claimed and the validity of the claim.

The Supplier shall provide complete cooperation during any such investigation.

mailto:Shane.Jasper@minneapolismn.gov mailto:submitinvoices@minneapolismn.gov

Trailer-Mounted Automatic Self-Priming Centrifugal Dewatering Pump Specification

1. Performance Requirements

The pump shall meet the following minimum performance requirements:

Requirement Specification Range

Maximum Flow Capacity 2,400 to 2,800 GPM

Maximum Total Dynamic Head 150 to 180 feet

Best Efficiency Flow Rate 1,800 to 2,200 GPM

Peak Pump Efficiency Minimum 75%

Solids Handling Capacity Minimum 3 inches diameter

Suction Size 6 inches

Discharge Size 6 inches

Automatic Priming Required

2. Pump Construction

2.1 Pump Type

• Centrifugal, self-priming pump.

• Capable of automatic priming without manual intervention.

• Designed for handling liquids containing suspended solids.

2.2 Impeller

• Closed or semi-closed impeller design.

• Two or more vane construction.

• Nominal impeller diameter, between 11 and 13 inches.

2.3 Materials of Construction

The pump shall be manufactured from durable materials suitable for abrasive and corrosive service.

Component Acceptable Materials

Pump Casing ASTM A536 ductile iron, high-strength cast iron, or equivalent

Impeller Ductile iron or equivalent wear-resistant alloy

Wear Components Include an ASTM A48 Class 20 Grey Iron, replaceable wear rings and wear plates

Shaft Stainless steel or equivalent corrosion-resistant alloy

Mechanical Seal Faces Silicon carbide, tungsten carbide, or equivalent and seals VITON elastomers

Elastomers Nitrile, fluoroelastomer, or equivalent

3. Priming System

• Vacuum-assisted automatic priming system.

• Capable of rapid priming under dry suction conditions.

• Air handling capacity of approximately 40 to 60 CFM.

• Ability to achieve vacuum levels suitable for self-priming applications.

• Priming components shall be serviceable and protected from environmental exposure.

4. Engine Requirements

4.1 Power Unit

• Diesel engine meeting current U.S. EPA emissions requirements at the time of manufacture.

• Four-cylinder liquid-cooled configuration preferred.

• Power rating under 75 horsepower.

• Variable speed operation.

• Electric starting system.

4.2 Electrical System

• 12-volt starting and charging system.

• Heavy-duty maintenance-free battery.

5. Fuel System

• Integrated fuel tank with minimum capacity of 80 gallons.

• Constructed of corrosion-resistant material.

• Unit shall be capable of extended unattended operation.

• Fuel consumption data shall be supplied by the bidder.

6. Control System

The pump package shall include:

• Local manual controls.

• Automatic start/stop functionality.

• Capability to operate from float switches, pressure transducers, level transducers, or equivalent devices.

• Engine monitoring and shutdown protection for:

o Low oil pressure o High coolant temperature o Overspeed o Low battery voltage o Low fuel level (preferred)

7. Trailer Assembly

The pump shall be mounted on a highway-capable trailer and shall include:

• Heavy-duty structural steel frame.

• Lifting eye or lifting frame.

• Forklift pockets.

• Stabilizing jack(s) as required.

• Safety chains.

• DOT-compliant lighting.

• Fenders and wheel assemblies.

• Access panels or hinged doors for maintenance.

Trailer shall be designed to safely support the complete operating weight of the pump package. one trailer shall be closed canopy (sound-attenuated - enclosed) and other trailer to be open canopy (skid-mounted / exposed).

8. Coating and Corrosion Protection

• Structural components shall be coated with industrial-grade corrosion-resistant finish.

• Powder coating, epoxy coating, or equivalent accepted.

• Coating system shall be suitable for outdoor exposure and wet environments.

9. Serviceability

The pump package shall be designed for routine maintenance and inspection and shall include:

• Direct access to impeller inspection area.

• Replaceable wear components.

• Accessible lubrication points.

• Easily removable covers and inspection plates.

10. Submittal Requirements

Bidder shall provide:

1. Pump performance curve.

2. Dimensional drawing.

3. Equipment weight.

4. Fuel consumption information.

5. Materials of construction list.

6. Maintenance requirements.

1. A recommended list of spare parts.

7. Warranty information.

1. A copy of the engine manufacturer's parts and labor warranty.

2. A one-year Parts and Labor Warranty issued by the manufacturer on the Portable Pump.

The warranty must cover all pump parts, including the mechanical seal.

8. Operation and maintenance manuals for the pump and engine must be supplied by the awarded supplier.

11. Approved Equal Clause

The specification is intended to describe the functional and performance requirements of the equipment. Any manufacturer may propose equipment that meets or exceeds the stated requirements.

Equipment offered shall be fully compatible with the intended application and supported by documented performance data demonstrating compliance with all requirements contained herein.

SPECIFICATIONS
OVERVIEW/PURPOSE
BASIS OF AWARD:
ITEM DESCRIPTIONS:
NON-EXCLUSIVE:
RIGHTS OF THE CITY:
GENERAL REQUIREMENTS:
QUALITY OF MATERIALS:
DELIVERY INFORMATION:
INVOICE AND PAYMENT:

File details come from the government source that posted it. Updated .