This is a bid package containing construction plans for the Lake Linden Trail Restoration project prepared by the State of Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division, located in Hancock, Michigan. The project involves restoration of a section of the Calumet-Hecla Trail designated as Segment 6, spanning from station 361+00 to station 377+50 (approximately 1,050 feet). The scope of work includes installation of multiple culverts in various configurations (24-inch, 36-inch, and 48-inch diameter concrete and class-rated culverts), slope restoration using Type D specifications, aggregate surface installation with 8-inch composite surface course, subbase preparation with 6-inch cast-in-place concrete, plunge pool construction per standard details, clearing and grading within a 100 to 170-foot right-of-way, temporary bypass pumping and discharge channels, and dewatering of low areas. The project encompasses approximately 132 feet of 48-inch Class D culvert at 3.40% grade and 42 feet of 24-inch Class A culvert at 5.18% grade, with excavation limits and trail centerline profiles detailed across multiple sheets.

The construction plans reference standard details on Sheet 63 for plunge pools and Sheet 61 for culvert installation specifications, with structural repairs and additional details provided on Sheets 65 and 66. Culvert invert elevations are to be determined in the field to ensure positive drainage. The project requires coordination with a privately owned section of the Calumet-Hecla Trail and compliance with subsurface utility location requirements ("Know what's below. Before you dig"). The plans were prepared by OHM Advisors and are dated November 7, 2022, with the project number identified as 7136-20-0040.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

373+00374+00375+00376+00377+00

S

T M

Know what's below.

before you dig.Call

R feetGRAPHIC SCALE: FULL feetHALF

60402010

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\P lan s_ Co ns t\2

0C

ON

_S

EG

6_ 1.d wg

N ov

, 2

2 -

:52 pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

(170' R.O.W.)

CULV, CL A, 24 INCH

KEY PLAN

W

S

T

M

Q

U

A

R

R

Y

D

M -2

G R

E G

O R

Y

S

T

NTS

AGGREGATE SURFACE CSE, 8 INCH

PLUNGE POOL, SEE STANDARD DETAIL ON SHEET 63

SLOPE RESTORATION TYPE D

PROPOSED TRAIL

E12

E12

CULV, END SECT, 24 INCH (TYP)

CULV, CL D, CONC, 48 INCH

PLUNGE POOL, SEE STANDARD DETAIL ON SHEET 63

E12

AGGREGATE SURFACE CSE, 8 INCH

SLOPE RESTORATION TYPE D

CULV, END SECT, 48 INCH (TYP)

E12

372+00

373+00

374+00

375+00376+00

377+00377+50

Know what's below.

before you dig.Call

R

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\P ro file s\2

0P

RF

_S

EG

6_

, 2

2 -

:52 pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

PROPOSED TRAIL CENTERLINE PROFILE

MATCH EXISTING TRAIL GRADE

MATCH EXISTING TRAIL GRADE

APPROXIMATE EXCAVATION LIMITS

132 FT CULV, CL D CONC, 48 INCH @ 3.40%

42 FT CULV, CL A, 24 INCH @ 5.18%

1.0'

STA 377+50-STA 372+00 PROPOSED TRAIL CENTERLINE PROFILE

APPROXIMATE EXCAVATION LIMITS

1.0'

Know what's below.

before you dig.Call

R feetGRAPHIC SCALE: FULL feetHALF

60402010

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\R em ov al\

RE

M_

SE

G6 _1

.dw g

N ov

, 2

2 -

:54 pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

(170' R.O.W.)

M

Q

U

A

R

M -2

G R

E G

O R

Y

S

T

NTS

LIMITS OF CLEARING (TYP)

PERFORM CLEARING AS NEEDED TO COMPLETE PROPOSED REPAIRS

TEMPORARY BYPASS PUMPING DISCHARGE CHANNEL

DEWATER LOW AREA INCIDENTAL TO PROPOSED PAY ITEMS

ACCESS ROAD TO PRIVATELY OWNED SECTION OF CALUMET-HECLA TRAIL

367+00

368+00

369+00

370+00

371+00

372+00

Know what's below.

before you dig.Call

R feetGRAPHIC SCALE: FULL feetHALF

60402010

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\P lan s_ Co ns t\2

0C

ON

_S

EG

6_

, 2

2 -

:56 pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

(170' R.O.W

SEE SHEET 65 FOR STRUCTURAL REPAIRS AND DETAILS

M

Q

U

A

R

M -2

G R

E G

O R

Y

S

T

NTS

SLOPE RESTORATION, TYPE D

SUBBASE, CIP (6")

8" AGGREGATE SURFACE CSE

367+00368+00369+00370+00371+00372+00372+50

Know what's below.

before you dig.Call

R

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\P ro file s\2

0P

RF

_S

EG

6_

, 2

2 -

:56 pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

PROPOSED TRAIL CENTERLINE PROFILE

STA 372+50-STA 367+00 PROPOSED TRAIL CENTERLINE PROFILE

SEE SHEET 65 FOR REPAIR DETAILS

F

S F

SF

S

F

S

F

Know what's below.

before you dig.Call

R feetGRAPHIC SCALE: FULL feetHALF

60402010

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\R em ov al\

RE

M_

SE

G6 _2

.dw g

N ov

, 2

2 -

:58 pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

(170' R.O.W

(100' R.O.W.)

M

Q

U

A

R

M -2

G R

E G

O R

Y

S

T

NTS

LIMITS OF CLEARING (TYP)

CLEARING

TEMPORARY BYPASS PUMPING DISCHARGE CHANNEL

PERFORM CLEARING AS NEEDED TO COMPLETE PROPOSED REPAIRS

361+00

362+00

363+00

364+00365+00

366+00

Know what's below.

before you dig.Call

R feetGRAPHIC SCALE: FULL feetHALF

60402010

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\P lan s_ Co ns t\2

0C

ON

_S

EG

6_ 2.d

, 2

2 -

1:

pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

(170' R .O

.W

(100' R.O.W.)

SEE SHEET 66 FOR STRUCTURAL REPAIRS AND DETAILS

M

Q

U

A

R

M -2

G R

E G

O R

Y

S

T

NTS

CULVERT, CL C, 36 INCH

PLUNGE POOL, SEE STANDARD DETAIL ON SHEET 63

E12

AGGREGATE SURFACE CSE, 8 INCH

SLOPE RESTORATION TYPE D

CULV, END SECT, 36 INCH (TYP)

E12

REPAIR WASHOUT, SEE DETAIL SHEET 61 FOR CULVERT INSTALLATION

361+00362+00363+00364+00365+00366+00367+00

APPROXIMATE EXCAVATION LIMITS

100 FT CULV, CL C, 36 INCH

INVERT ELEVATIONS SHALL BE DETERMINED IN THE FIELD TO PROVIDE POSITIVE DRAINAGE

Know what's below.

before you dig.Call

R

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\P ro file s\2

0P

RF

_S

EG

6_ 2.d

, 2

2 -

1:

pm

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

MATCH EXISTING TRAIL GRADE

STA 367+00-STA 361+00 PROPOSED TRAIL CENTERLINE PROFILE

SEE SHEET 66 FOR

STRUCTURAL REPAIR DETAILS

File details come from the government source that posted it. Updated .