This is a bid package containing construction plans for the Lake Linden Trail Restoration project administered by the State of Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division, located in Hancock, Michigan. The plans document detailed civil engineering specifications for trail restoration work, including naturalization typicals, erosion and sediment control measures, and culvert repair and installation. The project scope encompasses multiple site locations along what appears to be a trail corridor, with specific attention to Quincy Creek culvert work involving both arch-top and box culvert installations, ranging from 24-inch to 5.5-foot wide structures. The plans include detailed cross-sections, elevation views, and construction notes for various downstream headwall configurations at multiple project sites, with specific elevation and dimension specifications provided for construction guidance.

The technical specifications indicate an assumed bearing capacity of 2,000 pounds per square foot for foundation work, with provisions for contractor notification to the engineer if unsatisfactory soil conditions are encountered during excavation. The plans specify geotextile liner placement requirements on all slopes prior to riprap installation, with payment for geotextile materials included in riprap costs. The contractor assumes sole responsibility for completing installation according to the design and construction drawings and for verifying site conditions prior to structure installation. The engineer disclaims responsibility for settlement, foundation failures, or installation deficiencies. The plans were prepared by OHM Advisors on behalf of the state and are dated November 7, 2022.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SFSF

S F

S F

S F

S F

S F

S F

S F

S F

S F

S F

S F

S F

S F

S F

S

F

S

F

Know what's below.

before you dig.Call

R

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\D eta ils \20

DE

T2

-2 .dw g N ov

, 2

2 - 9:

am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

NATURALIZATION TYPICALS2

EXISTING / REMOVALS PLAN VIEW3

TYPICAL NATURALIZATION PROFILE4

TYPICAL NATURALIZATION SECTION1

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\D eta ils \20

DE

T2

-3 .dw g N ov

, 2

2 - 9:

am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

EARTH DIVERSION BERM1CHECK DAMS2

NOTE: CHECK DAMS GREATER THAN TWO FEET IN DEPTH MAY

SERIOUSLY IMPACT THE FLOW CHARACTERISTICS OF THE DITCH

RIPRAP SLOPE3

SLOPE BENCHING8

SILT FENCE5

SEDIMENT TRAP7

ROCK LINED CHANNEL6 VEGETATION BUFFER ZONE4

NOTE: USE MDOT PLAIN RIPRAP AT 10% OR LESS SLOPES OR

<5.5FPS STREAM VELOCITY. USE MDOT HEAVY RIPRAP AT SLOPES

>10% OR >5.5FPS STREAM VELOCITY.

PLUNGE POOL10

C

H A

N N

E L

B

A S

E

W

I D

T H

2'

V A

R I E

S

V A

R I E

S

CHECK DAM (PERMANENT)8

CLEAR AND TRIM 14' WIDE AND 20' CLEARANCE

EXISTING GRADE

PROPOSED TRAIL SECTION9

Know what's below.

before you dig.Call

R

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\D eta ils \20

DE

T_

Qu inc y C re ek C ulv er t.d wg

N ov

, 2

2 - 9:

am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

INLET SECTION B-B4EXISTING CULVERT1

INLET SECTION A-A2

INLET DETAIL3

5.8'

5.5' Wide x 135.0' Arch Top Culvert

5.8' Wide x 35.0' Box Culvert

SEE SHEET 74 FOR REPAIR DETAILS

RAILROAD TIE

RAILROAD TIE

PATCHING, MORTAR OR CONC

HAND CHIPPING, SHALLOW

RAILROAD TIE

EXISTING CONCRETE WINGWALL

EXISTING CULVERT

EXISTING CONCRETE WINGWALL

EXISTING CULVERT

R

R

Ex. Railroad Tie

EX ROCK RETAINING WALL

PATCHING, MORTAR OR CONC

HAND CHIPPING, SHALLOW

PATCHING, MORTAR OR CONC

HAND CHIPPING, SHALLOW

INLET5

EL 639.69 B/CULV BEDDING UPSTREAM

EL 636.16 B/CULV BEDDING DOWNSTREAM

5'-6"

PROPOSED GRADE

2'-0"

TYP

EL 641.69CULV INV UPSTREAM

EL 638.16 CULV INV DOWNSTREAM

17'-6" 17'-6"

CULV BEDDING, BOX CULV

EL 638.16 CULV INV DOWNSTREAM

EL 641.69 CULV INV UPSTREAM

(APPROX ELEVATION, FIELD VERIFY)

℄ CONST

EL 646.66 T/HEADWALL

EL 645.46 NE QUAD

EL 645.46 SE QUAD

BACKFILL STRUCTURE, CIP

TIE INTO EXISTING CULVERT

EXISTING CULVERT

WRAP JOINT WITH FABRIC, PAID

FOR AS, _8OZ, GEOTEXTILE,

NON-WOVEN

2'-0"

AA

PROPOSED GRADE

T

Y P

0'-8" TYP

Know what's below.

before you dig.Call

R

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E R

E I

S

P E

N I

N S

U

L A

M

A M

O E

N A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\D eta ils \20

DE

T_

Qu inc y C re ek C ulv er

, 2

2 - 9:

am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

NOTES

1. ASSUMED BEARING CAPACITY = 2000 POUNDS PER SQUARE FOOT (CONTRACTOR TO NOTIFY ENGINEER IF UNSATISFACTORY SOILS ARE

FOUND DURING EXCAVATION).

2. ANY SUBSURFACE CONDITIONS OR EXISTING FOUNDATIONS ENCOUNTERED THAT ARE NOT REPRESENTED ON THE PLANS OR IN THE

SPECIFICATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER FOR THE INSPECTION AND/OR AN ALTERNATE

FOUNDATION/FOOTING DESIGN.

3. THE ENGINEER IS NOT RESPONSIBLE FOR ANY SETTLEMENT OF STRUCTURE, FOUNDATION FAILURES, PRECAST FAILURES, SCOUR

FAILURES OR POOR INSTALLATION PRACTICES BY THE CONTRACTOR. ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR

CLAIMS RELATED TO THIS PRECAST CONCRETE BOX DESIGN AND WINGWALL. SITE CONDITIONS SHALL BE VERIFIED BY CONTRACTOR

PRIOR TO STRUCTURE INSTALLATION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COMPLETING THE INSTALLATION ACCORDING

TO THE ORIGINAL DESIGN/CONSTRUCTION DRAWINGS.

4. GEOTEXTILE LINER SHALL BE PLACED ON ALL SLOPES PRIOR TO PLACING RIPRAP. PAYMENT FOR GEOTEXTILE LINER SHALL BE INCLUDED

IN PAYMENT FOR RIPRAP.

5. SEE SHEET 73 FOR QUANTITIES

OUTLET3

SECTION - ALONG CULVERT 1 ℄

SECTION AA2

ELEVATION4

Know what's below.

before you dig.Call

R

P

L

U

R I

B U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S I

Q U

E

R E

I

S P

E N

I N

S U

L A

M A

M O

E N

A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ La ke _L ind en

_T ra il_ Re sto ra tio n_

\D ra wi ng s\C ivi l\T ra il\D eta ils \20

DE

T_

Qu inc y C re ek C ulv er

, 2

2 - 9:

am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

7136-20-0040

SITE 587+51.97 DOWNSTREAM HEADWALL PLAN VIEW2SITE 522+35.79 DOWNSTREAM HEADWALL PLAN VIEW4 SITE 522+35.79 DOWNSTREAM HEADWALL ELEVATION VIEW3

SITE 520+12.96 DOWNSTREAM HEADWALL ELEVATION VIEW5

SITE 587+51.97 DOWNSTREAM HEADWALL ELEVATION VIEW1

5.2'

SITE 520+12.96 DOWNSTREAM HEADWALL PLAN VIEW6SITE 517+33.94 DOWNSTREAM HEADWALL PLAN VIEW8 SITE 517+33.94 DOWNSTREAM HEADWALL ELEVATION VIEW7

SITE 505+79.04 DOWNSTREAM HEADWALL PLAN VIEW10 SITE 505+79.04 DOWNSTREAM HEADWALL ELEVATION VIEW9

24" CULVERT

GRADE BACK OF WALL

FOOTING

CONC HEADWALL

FOOTING

CONC HEADWALL

36" CULVERT

GRADE BACK OF WALL

FOOTING

CONC HEADWALL

6.2'

FOOTING

CONC HEADWALL

13.2'

48" CULVERT

GRADE BACK OF WALL

FOOTING

CONC HEADWALL

FOOTING

CONC HEADWALL

FOOTING

CONC HEADWALL

FOOTING

CONC HEADWALL

48" CULVERT

GRADE BACK OF WALL

FOOTING

CONC HEADWALL

24" CULVERT

GRADE BACK OF WALL

FOOTING

CONC HEADWALL

13.2'

5.2'

File details come from the government source that posted it. Updated .