Summary of Lewis County Preventative Bridge Maintenance Project
This is a set of technical plans and specifications for the Preventative Bridge Maintenance Project (CRP 2199) managed by Lewis County, Washington. The project involves preventative maintenance and repairs to a bridge on Hining Road at mile post 0.23 spanning Ole Quac Creek. The scope of work includes removal and replacement of existing hot mix asphalt (HMA) with a modified concrete overlay on the bridge deck, repair of spalled girder flanges, application of unidirectional carbon fiber reinforced polymer (CFRP) strips to girders for structural reinforcement, epoxy injection of cracks in abutments, and repair of spalls and delaminations in concrete abutments. The existing structure consists of 42-inch prestressed concrete deck bulb-T girders with six longitudinal girders and five existing post-tensioned diaphragms. The project includes detailed repairs to 17 identified spall and delamination defects on girder bottom and top flanges, with repair dimensions ranging from 1 to 7 feet in length and depths up to 7 inches. All work must be completed under full lane closure. Sealed bids are due by 12:15 PM on Thursday, December 17, 2026, submitted to the Clerk of the Board of Lewis County Commissioners or electronically through the procurement portal. A bid proposal deposit equal to five percent of the bid amount is required.
The plans indicate that all work must comply with Washington State Department of Transportation (WSDOT) standards and specifications, including erosion and sediment control (ESC) measures and traffic control provisions. Construction is restricted to specific environmental windows, with temporary work platform installation permitted only between July 15 and October 1 at a minimum elevation of 260.0. The project includes staging areas, stabilized construction entrances, inlet protection, and comprehensive traffic control with lane closures and detour routes. Contact information for inquiries is provided through the Lewis County Public Works Department, with Assistant County Engineer Vince Hall listed as the primary contact. Contract documents are available through the county's website (www.lewiscountywa.gov) or by calling the Engineers office at (360) 740-1123 Extension 2.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Preventative_Bridge_Maintenance_Project.pdf | ||
| BA00-G~1.PDF | ||
| BridgePreventativeMaintenance_cleanFINAL.pdf | ||
| BB00-G~1.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IDENTIFIES SECTION OR VIEW
LETTER
SHEET NUMBER WHERE SECTION OR
VIEW IS SHOWN
IDENTIFIES DETAIL NUMBER
DASH INDICATES SECTION, VIEW, OR
DETAIL IS TAKEN AND SHOWN ON THE
SAME SHEET
LEGEND
A B-08
A
ABBREVIATIONS:
AP ANGLE POINT
AVE AVENUE
BFE BASE FLOOD ELEVATION
BMP BEST MANAGEMENT PRACTICE
CL & L CENTERLINE
CY CUBIC YARD
DIA DIAMETER
DWG DRAWING
E EAST/EASTING
EL & ELEV ELEVATION
ESC EROSION AND SEDIMENT CONTROL
FT & ' FEET
HMA HOT MIX ASPHALT
IN & " INCHES
LF LINEAR FOOT
LS LUMP SUM
LT LEFT
MAX MAXIMUM
MIN MINIMUM
MUTCD MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES
N NORTH/NORTHING
OHU OVERHEAD UTILITY
OHW ORDINARY HIGH WATER MARK
PPC POLYESTER POLYMER CONCRETE
R RADIUS
RD ROAD
R/W & ROW RIGHT OF WAY
RT RIGHT
S SOUTH
SEC SECTION
STA STATION
SY SQUARE YARD
TESC TEMPORARY EROSION AND
SEDIMENT CONTROL
TC TRAFFIC CONTROL
TYP TYPICAL
W WEST
WSDOT WASHINGTON STATE DEPARTMENT
OF TRANSPORTATION
C
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9- C
O
VE
R S
H T.
dw g
/1
8/
:1
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 G-02
02 11
NN
DJ
JK
12/01/2025
G-02 - GENERAL NOTES AND
ABBREVIATIONS
TRPP FH
TR
SP
WV
DT
DT
DT
DT
PP
TR
SEW
ERM
A N
H O L E
WM
WV
WM
PP FH
WV
SEW
E
RM
A N
H O L E
WM
WM
SSCO
SS
CO
SEW
E
RM
A N
H O L E
SP
SEW
E
RM
A N
H O L E
X
X
GA
TE
GA
TE
GATE
X
X
X
X
X
TO
P
GR
GR
OHU OHU OHU OHU OHU OHU OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TPHONE
WM
WM
WM
WATERWATER
SEWER SEWER
TO
P
TO
P
TO
E
TO
E
TO
E
TOE
WATERWATERWATER
WATER
WATERWATER
SEWERSEWERSEWERSEWER
WATER
WATER
WATER
W
ATER
W
ATER
W
ATER
SEWER
SEWER
S E W E R
OHU
OHU
OHU
OHU
OHU
OHU
OHU
TOE
TOE
MAG
S P
I K E
5 26
271272
PLS
PLS
PLS
PLS
PLS
MAG
N
A I L
MAG
S P
I K E
S URV
E Y
M O N
U M E N T
TRPP FH
TR
SP
WV
DT
DT
DT
DT
PP
TR
SEW
ERM
A N
H O L E
WM
WV
WM
PP FH
WV
SEW
E
RM
A N
H O L E
WM
WM
SSCO
SS
CO
SEW
E
RM
A N
H O L E
SP
SEW
E
RM
A N
H O L E
GA
TE
GA
TE
GATE
TO
P
GR
GR
OHU OHU OHU OHU OHU OHU OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TP
HO
NE
TPHONE
WM
WM
WM
WATERWATER
SEWER SEWER
TO
P
TO
P
WATERWATERWATER
WATER
WATERWATER
SEWERSEWERSEWERSEWER
WATER
WATER
WATER
W
ATER
W
ATER
W
ATER
SEWER
SEWER
S E W E R
OHU
OHU
OHU
OHU
OHU
OHU
OHU
MAG
S P
I K E
PLS
PLS
PLS
PLS
PLS
MAG
N
A I L
MAG
S P
I K E
S URV
E Y
M O N
U M E N T
OHW
OHW
OHW
O
HW
O H
W
O H
W
O H
W
O H
W
OHW
OHW
O
HW
OHW
O H
W
OHW
OHW
OHW
O
HW
O
HW
O
HW
STAGING AREA
SHORELINE
ENVIRONMENT
FEMA MAPPED
100-YEAR
FLOODPLAIN
SHORELINE
ENVIRONMENT
SHORELINE BUFFER
SHORELINE BUFFER
SHORELINE BUFFER
SHORELINE
ENVIRONMENT
FEMA MAPPED
100-YEAR
FLOODPLAIN
PROTECT EXISTING
FIRE HYDRANT
INLET PROTECTION
(TYP.)PROJECT LIMITS
ROW
PROJECT
LIMITS
ROW
HINING ROAD
MP 0.23 BRIDGE
3+00
4+00
5+00
6+
7+
8+
OHW
LEGEND
ORDINARY HIGH WATER (EL. 254.0')
STAGING AREA
STABILIZED CONSTRUCTION ENTRANCE PER
WSDOT STD. PLAN I-80.10-02
FEMA MAPPED 100-YEAR FLOODPLAIN
SHORELINE BUFFER
SHORELINE ENVIRONMENT
PROJECT LIMITS
INLET PROTECTION - SEE WSDOT STD SPEC
SECTION 8-01.3(9)D
20 0 20
57 WEST MAIN ST
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
SP
P
LA
N S.
dw g
/1
8/
:1
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 G-03
03 11
CHED
CHED
JJ
06/01/2026 G-04 - SITE PREP & TESC PLAN
EROSION AND SEDIMENT CONTROL NOTES:
1. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH ALL GRADING SO AS TO ENSURE THAT THE
TRANSPORT OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS, AND ADJACENT PROPERTIES IS PREVENTED.
2. THE ESC FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR THE ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND MODIFIED TO ACCOUNT
FOR CHANGING SITE CONDITIONS.
3. ALL GRADING SHALL BE CONTAINED WITHIN THE LIMITS ESTABLISHED BY THE ENGINEER. ALL VEGETATION OUTSIDE DESIGNATED LIMITS SHALL
REMAIN UNDISTURBED.
4. ALL STOCKPILES ARE TO BE LOCATED IN SAFE AREAS AND PROTECTED FROM EROSION.
5. ALL EXPOSED AND UNWORKED SOILS SHALL BE STABILIZED BY SEEDING, MULCHING, MATTING, OR PLASTIC COVERING. FROM OCT. 1 TO APRIL 30, NO SOILS SHALL REMAIN UNSTABILIZED FOR MORE THAN 2 DAYS. FROM MAY 1 TO SEPT. 30, NO SOILS SHALL REMAIN UNSTABILIZED FOR MORE
THAN 7 DAYS.
6. ALL POLLUTANTS OTHER THAN SEDIMENTS THAT OCCUR ON-SITE DURING CONSTRUCTION SHALL BE HANDLED AND DISPOSED OF IN A MANNER THAT DOES NOT CAUSE CONTAMINATION OF STORMWATER PER CURRENT VERSION OF DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT
MANUAL.
7. SEDIMENTS TRANSPORTED ONTO A ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM ROADS BY SHOVELING OR SWEEPING AND BE TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. ALL COSTS ASSOCIATED WITH THIS WORK SHALL BE INCIDENTAL TO THE VARIOUS
BID ITEMS.
8. NO GROUND DISTURBANCE SHALL TAKE PLACE IN STAGING AREA.
PLAN
PROFILE GRADE
& PIVOT POINT
11'-0"±
L HINING ROADC
22'-0"±
11'-0"±
0.01'±/FT 0.01'±/FT
LANE LANE
REMOVE AND REPLACE
EXISTING HMA WITH "MODIFIED
CONCRETE OVERLAY"
REPAIR SPALLED
GIRDER FLANGE (TYP)
24'-0"±
EXIST SEWER PIPE
EXIST WATER PIPE 12
L GIR AC L GIR BC L GIR CC L GIR DC L GIR EC L GIR FC
FEMA 100-YR BFE ELEV 261.4 (SHOWN)
EXIST 42" PRESTRESSED CONC
DECK BULB-T GIRDERS (TYP)
EXISTING POST TENSIONED
DIAPHRAGMS (TOTAL 5)
UNIDIRECTIONAL CFRP STRIPS
OHW ELEV 254.0
DT
DT
DT
DT
PP
TR
SEW
E
RM
A N
H O L E
WM
WV
XTO
P
GR
GRGR
GR
GR
GR GR GR GR GR
GR
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
TP
HO
NE
TP
HO
NE
TP
HO
NE
W A T E R
W A T E R
WATER
WATER
WATERWATERWATERWATERWATERWATERWATERWATER
SEWER SEWER SEWER SEWER SEWER SEWER SEWER
TO
P
T O P
TO
P
TO
P
T
TO
E
T O E
TO
E
TO
E
TO
E
TO
E
WATERWATERWATERWATERWATER
SEWERSEWERSEWERSEWERSEWER
W
ATER
W
ATER
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
OHU
T O E
T O E
TO
E
PLS
MAG
S P
I K E
6+
7+
00 HINING ROAD
REPAIR CRACKS
IN ABUTMENT 1
'-0
'-0
'-0
END BRIDGE
(ABUTMENT 2)
BEGIN BRIDGE
(ABUTMENT 1)
REPAIR SPALL
IN ABUTMENT 1
'-0
EXIST SEWER PIPE
EXIST WATER PIPE
75'-8"±
LA
N
E
R O
AD
W
AY
LA
N
E
L GIR FC
EPOXY INJECT
CRACK IN ABUTMENT
REPAIR SPALL
IN ABUTMENT 2
EXIST ROW
EXIST ROW
L GIR EC
L GIR DC
L GIR CC
L GIR AC
L GIR BC
O
LE
Q U
A C
R
EE
K
'-0
'-0
PLAN
TYPICAL BRIDGE SECTION
LIMITS OF DECK HMA OVERLAY
LEGEND
1. REMOVE EXISTING HMA FROM THE BRIDGE DECK.
2. PERFORM LOCALIZED DECK REPAIRS ON TOP
FLANGES.
3. APPLY MODIFIED CONCRETE OVERLAY MATCHING
THE EXISTING BRIDGE PROFILE.
4. PATCH AND REPAIR THE GIRDER FLANGES TO
RECONSTRUCT THE FLANGES TO THEIR ORIGINAL
SHAPES.
5. ATTACH CFRP LAYERS TO GIRDERS.
6. REPAIR SPALLS, DELAMINATIONS, AND CRACKS IN
ABUTMENTS.
7. ALL REPAIRS AND OVERLAY SHALL BE
COMPLETED UNDER FULL LANE CLOSURE.
WORK DESCRIPTION
GIRDER REPAIR. SEE "GIRDER REPAIR DETAILS"
SHEET FOR SPALLED LOCATIONS.
EXISTING WATER AND SEWER UTILITIES MAY BE
RELOCATED AS NECESSARY TO PERFORM THE
GIRDER REPAIRS.
KEY NOTES:
LOOKING AHEAD ON STATIONING
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E
PL
AN
S.
dw g
/1
8/
:2
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 B-01
04 11
NN
DJ
JK
12/01/2025
B-01 - BRIDGE LAYOUT AND TYPICAL
SECTION
DATUM
NAVD 1988
PHOTO 6
PHOTO 4
L HINING ROADC L HINING ROADC
L GIR AC L GIR BC L GIR CC
4 - UNIDIRECTIONAL
CFRP LONGITUDINAL
STRIPS OVERLAP 3" MIN
CONCRETE REPAIR
DELAMINATION ON
ABUT FACE APPROX
2' x 2' (PHOTO 4)
CONCRETE REPAIR
SPALL ON GIRDER END DIAPHRAGM
APPROX 2' x 1' x 6" DEEP (PHOTO 5)
12" MIN6"
M
IN
EPOXY-INJECT CRACK IN
CLOSURE POUR
(APPROX 3 LF) (PHOTO 6)L GIR FC L GIR EC L GIR DC
PHOTO 5
LONGITUDINAL STRIPS SHALL BE 0.04" THICK x 12"
WIDE, CENTERED ON GIRDER BOTTOM FLANGE
FACE WITH PRIMARY FIBERS ORIENTED ALONG
THEIR LONG DIMENSIONS.
SEE "CONCRETE REPAIR DETAILS" SHEET FOR
GENERAL SPALL/DELAMINATION REPAIR DETAILS
KEY NOTES:
ELEVATION - ABUTMENT 2ELEVATION - ABUTMENT 1
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E D
ET
AI
LS
.d w g
/1
8/
:3
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 B-02
05 11
NN
DJ
JK
12/01/2025 B-02 - ABUTMENT REPAIR DETAILS
LOOKING BACK ON STATIONING
2 LOOKING BACK ON STATIONING 2
L GIRDER AC
L GIRDER BC
L GIRDER CC
L GIRDER DC
L GIRDER EC
L GIRDER FC
11 10 9
L DIAPHRAGM 1C L DIAPHRAGM 3CL DIAPHRAGM 2C L ABUT 2CL ABUT 1CPHOTO 7
PHOTO 8PHOTO 9PHOTO 10 PHOTO 11
PHOTO 17
PHOTO 18
PHOTO 19
PHOTO 15
PHOTO 16
PHOTO 12
PHOTO 13PHOTO 14
L HINING ROADC
L GIR AC L GIR BC L GIR CC L GIR DC L GIR EC L GIR FC
FEMA 100-YR BFE ELEV 261.4 (SHOWN)
CFRP GIRDER REPAIRS
OHW ELEV 254.0
4' -0
" 10 '-0
TEMPORARY WORK PLATFORM
ELEV 260.0 (MIN)
(M
IN
AVG. BOTTOM OF
GIRDER ELEV 267.32
CONTRACTOR SHALL MAINTAIN THE BOTTOM OF
THE TEMPORARY WORK PLATFORM AT OR ABOVE
ELEVATION 260.0. THIS WORK IS PERMITTED ONLY
BETWEEN JULY 15 AND OCTOBER 1.
CONTRACTOR SHALL NOT REMOVE ANY EXISTING
BRIDGE BARRIER RAILS WHEN INSTALLING THE
HANGING WORK PLATFORM.
KEY NOTES:
DEFECT
LABEL DESCRIPTION SIZE PHOTO #
1 SPALL BOTTOM FLANGE 1.75'(L) X 2.5"(W) X 4"(D) -
2 SPALL/DELAMINATION ON WEB 2'(L) X 2'(D) PHOTO 7
3 DELAMINATION BOTTOM FLANGE 2.8'(L) X 5"(W) X 7"(D) PHOTO 8
4 SPALL BOTTOM FLANGE 7’(L) X 9”(W) X 4"(D) PHOTO 9
5 DELAMINATION BOTTOM FLANGE 16’(L) -
6 SPALL BOTTOM FLANGE 2'(L) X 5”(W) X 5"(D) PHOTO 10
7 SPALL BOTTOM FLANGE 2.75’(L) X 4"(W) X 4"(D)
8 SPALL BOTTOM FLANGE 1.5'(L) X 6"(W) X 3"(D) -
9 PHOTO 12
10 SPALL TOP FLANGE 1.25'(L) X 4"(W) X 1.5"(D) PHOTO 13
11 SPALL BOTTOM FLANGE 1'(L) X 3"(W) X 2"(D) PHOTO 14
12 DELAMINATION BOTTOM FLANGE 1.25'(L) X 2"(W) X 3"(D) PHOTO 15
13 DELAMINATION BOTTOM FLANGE 3"(L) X 3"(W) X 3"(D) PHOTO 16
14 SPALL BOTTOM FLANGE 2'-6"(L) X 5”(W) X 3"(D) PHOTO 17
15 SPALL BOTTOM FLANGE 1.5'(L) X 3"(W) X 3"(D) PHOTO 18
16 SPALL BOTTOM FLANGE 1.5'(L) X 4"(D) X 5"(W) PHOTO 19
17 SPALL BOTTOM FLANGE 1.75'(L) X 4.5"(D) X 4"(W) -
1.5'(L) X 3"(W) X 2"(D)SPALL/DELAMINATION BOTTOM FLANGE
PHOTO 11
GIRDER REPAIR PLAN
HANGING WORK PLATFORM FOR ACCESSING GIRDER REPAIR
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E D
ET
AI
LS
.d w g
/1
8/
:0
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 B-03
06 11
NN
DJ
JK
12/01/2025 B-03 - GIRDER REPAIR DETAILS
DATUM
NAVD 1988
SEE "CONCRETE REPAIR DETAILS" AND "CFRP GIRDER
REHABILITATION DETAILS" SHEETS FOR REPAIR DETAILS.
TYPICAL GIRDER ELEVATION - BOTTOM CFRP STRIP LAYOUT
FACE OF ABUTMENT (TYP)
L GIRDERC
15'-0"
1'-0"1'-0"
3'-0" 17'-0"
18'-0"
16'-0"
3-LAYERS UNIDIRECTIONAL
CFRP LONGITUDINAL STRIPS
1-LAYER UNIDIRECTIONAL CFRP
END DEBONDING U-WRAPS (TYP)
MIN
MIN
MIN
MIN
END DEBONDING U-WRAPS
NOT SHOWN FOR CLARITY
EXISTING GIRDER
APPLY SECOND:
1-LAYER UNIDIRECTIONAL CFRP
END DEBONDING U-WRAPS (TYP)
APPLY FIRST:
3-LAYERS UNIDIRECTIONAL
CFRP LONGITUDINAL STRIPS (TYP)
1' -0
" M
IN
END DEBONDING U-WRAP DETAIL A
LONGITUDINAL STRIPS SHALL BE 0.04" THICK x 12"
WIDE, CENTERED ON GIRDER BOTTOM FLANGE FACE
WITH PRIMARY FIBERS ORIENTED ALONG GIRDER.
END DEBONDING U-WRAPS SHALL BE 0.04" THICK
x 12" WIDE. PRIMARY FIBERS ORIENTED VERTICAL.
KEY NOTES:
A
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E D
ET
AI
LS
.d w g
/1
8/
:0
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 B-04
07 11
NN
DJ
JK
12/01/2025
B-05 - CFRP GIRDER REHABILITATION
DETAILS
TYPE 2 DECK REPAIR
REMOVE ALL CONCRETE FULL
DEPTH AS SHOWN ON THE
PLANS AND AS REQUIRED BY
THE ENGINEER.
REPLACE EXISTING
REINFORCEMENT
WITH GREATER THAN
25% SECTION LOSS
PRESERVE AND CLEAN
REINFORCING STEEL WITH
LESS THAN 25% SECTION LOSS
PARTIAL DECK REPAIR DETAIL
GENERAL SPALL/DELAMINATION REPAIR DETAIL
1/4" TAPCON SCREWS, OR
APPROVED EQUAL. 6" MAX
SPACING, STAGERED, NOT
TO CONFLICT WITH EXIST
REINFORCEMENT. WOVEN
REINFORCED TIE WIRE NOT
SHOWN FOR CLARITY (TYP)
GENERAL CONCRETE
SPALL/DELAMINATION
FULL DEPTH DECK REPAIR DETAIL
EXISTING REINFORCEMENT
REPLACE EXISTING
REINFORCEMENT WITH
GREATER THAN 25%
SECTION LOSS
FULL DEPTH DECK REPAIR AREA.
PARTIAL DECK REMOVAL DETAIL
INTENTIONALLY
ROUGHEN SURFACE (TYP)
EXISTING BOTTOM
MAT REINFORCING
3/4" SAWCUT AT
EDGE OF REPAIR
AREA
SECTION A
SECTION B
PROTECT EXISTING
REINFORCING STEEL
1/4" TAPCON SCREW (TYP)
APPLY BONDING AGENT
TO ALL CONCRETE
REINFORCING SURFACES
REMOVE LOOSE CONCRETE
TO SOUND CONCRETE
SAWCUT 3/4" MAX
CLEAN AND COAT EXISTING REINFORCING
AND CONCRETE SURFACE WITH
CORROSION INHIBITOR (SIKA ARAMETEC
110 OR APPROVED EQUAL IF REQUIRED)
SAWCUT 3/4" MIN.
ALL EDGES (TYP)
REMOVE CONCRETE
TO PROVIDE 3/4" MIN
CLEARANCE
(OVERLAY NOT SHOWN FOR CLARITY)
(OVERLAY NOT SHOWN FOR CLARITY)
3/4" MAX SAW CUT
EXISTING TOP MAT
OF REINFORCING
TYPE 1 DECK REPAIR
TOP OF DECK
MID HEIGHT OF EXISTING TOP MAT
BOTTOM BAR, AREAS WHERE CONCRETE
IS REMOVED BELOW THIS LINE REQUIRE
TYPE 2 DECK REPAIRS. REPAIRS ABOVE
THIS LINE REQUIRE TYPE 1 DECK REPAIRS
(IF REQUIRED)
(IF REQUIRED)
A
B
TYPE 2 DECK REPAIRTYPE 1 DECK REPAIR
MATCH CONCRETE
OVERLAY CLASS M CONCRETE
GENERAL NOTES
1. THESE DETAILS REFLECT THE SCOPE AND THE NATURE OF THE WORK. THEY ARE NOT INTENDED TO REPRESENT THE ACTUAL
STRUCTURE.
2. BID ITEM QUANTITIES ARE ESTIMATES. ACTUAL CONCRETE SPALL AND REPAIR WILL BE AS NEEDED TO REACH SOUND
CONCRETE SUBSTRATE OR AS DIRECTED BY THE ENGINEER.
3. REMOVAL OPERATIONS SHALL BE COORDINATED WITH THE ENGINEER AND PERFORMED IN A MANNER AS REQUIRED TO
ENSURE THE STRUCTURAL INTEGRITY OF THE BRIDGE.
4. ALL DAMAGED OR CORRODED NON-EPOXY COATED REINFORCING STEEL REQUIRES NEW NON-EPOXY COATED REINFORCING STEEL TO BE ADDED. ALL EXPOSED NON-EPOXY COATED REINFORCING STEEL SHALL BE CLEANED WITH HAND TOOLS, STRAIGHTENED AND SANDBLASTED PRIOR TO PLACING CONCRETE.
5. OVERLAID DECK MAY BE OPENED TO TRAFFIC AS SOON AS NEW CONCRETE HAS ATTAINED REQUIRED STRENGTH.
6. INTENTIONALLY ROUGHEN ALL CONCRETE SURFACES RECEIVING REPAIR TO AN AMPLITUDE OF 1/4".
7. CONCRETE REPAIR SCREWS SHALL BE TAPCON, OR APPROVED EQUAL, SCREWS SHALL BE EMBEDED INTO SOUND CONCRETE
A MINIMUM OF 2". INSTALL PER MANUFACTURERS RECOMMENDATIONS. SCREWS ARE REQUIRED WHERE SHOWN IN THE DETAILS AND WHERE 1" CLEAR BEHIND REINFORCING IS NOT ACHIEVABLE. SCREWS WILL NOT BE MEASURED AND PAID FOR
SEPARATELY BUT SHALL BE INCLUDED IN CONCRETE REPAIR BID ITEM.
8. WEAVE 16 GAGE REINFORCING TIE WIRE, ASTM A1064 BETWEEN SCREWS TO FORM SPIDERWEB BETWEEN SCREWS. WIRE WILL NOT BE MEASURED AND PAID FOR SEPARATELY, BUT SHALL BE INCIDENTAL TO CONCRETE REPAIR BID ITEM.
9. REMOVE RUST AND DEBRIS FROM ALL EXPOSED REINFORCEMENT. CONTRACTOR SHALL SPLICE AND REPLACE
REINFORCEMENT AS NEEDED.
10. PROTECT EXISTING REINFORCING IN PLACE. CONTRACTOR SHALL NOTIFY THE ENGINEER IF REINFORCING IS DAMAGED.
11. PROVIDE A MINIMUM OF 1" CLEAR BETWEEN REINFORCING AND PREPARED SURFACE.
12. ALL SURFACES SHALL RECEIVE AN EPOXY CONCRETE BINDER PRIOR TO PLACING CONCRETE. EPOXY BINDER SHALL BE SIKA ARMATECK - 100 EPOCEM OR APPROVE EQUAL. BINDER IS INCIDENTAL TO CONCRETE REPAIR BID ITEM.
13. ALL CAST-IN-PLACE CONCRETE SHALL BE CLASS 4000D FOR CONCRETE DECKS AND CLASS 4000 FOR ALL OTHER CONCRETE.
14. UNLESS OTHERWISE SHOWN IN THE PLANS, CONCRETE COVER MEASURED FROM THE FACE OF CONCRETE TO THE FACE OF
ANY REINFORCING STEEL SHALL BE 2".
15. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3 4", UNLESS NOTED OTHERWISE.
16. REINFORCING BARS SHALL CONFORM TO ASTM A706 GRADE 60 UNLESS OTHERWISE NOTED. THE MINIMUM LAP SPLICE FOR
REINFORCING BARS SHALL BE AS SHOWN IN THE TABLE BELOW.
BAR SIZES:
SPLICE LENGTH (TOP BARS):
#4
2'-0"
#5
2'-7"
#6
3'-1"
#7
3'-7"
#8
4'-1"
SPLICE LENGTH (EPOXY COATED):
2'-0" 2'-4" 2'-9" 3'-2"
TOP BARS ARE HORIZONTAL BARS PLACES SUCH THAT MORE THAN 12" OF CONCRETE IS CAST BELOW REINFORCEMENT.
5'-2" 6'-5" 7'-8" 8'-11" 10'-3"
1'-3"SPLICE LENGTH (OTHERS):
GENERAL SPALL REPAIR DETAIL APPLIES TO BOTH
HORIZONTAL AND VERTICAL SURFACES. VERTICAL
SURFACE DETAIL SHOWN; OTHERS SIMILAR.
KEY NOTES:
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E D
ET
AI
LS
.d w g
/1
8/
:2
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
HINING ROAD MP 0.23 B-05
08 11
NN
DJ
JK
12/01/2025 B-06 - CONCRETE REPAIR DETAILS
MINIMUM LANE CLOSURE TAPER LENGTH = L (feet)
LANE
WIDTH
(feet)
Posted Speed (mph)
CHANNELIZATION DEVICE
SPACING (feet)
SHOULDER
WIDTH
(feet)
Posted Speed (mph)
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
USE A MINIMUM OF 3 DEVICES TAPER
FOR SHOULDER LESS THAN 8'
LONGITUDINAL BUFFER SPACE = B
BUFFER DATA
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 lbs.
HOST VEHICLE WEIGHT
> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS
URBAN STREETS
RURAL HIGHWAYS
FREEWAYS & EXPRESSWAYS
SIGN SPACING = X (1)
RURAL ROADS & URBAN ARTERIALS
RESIDENTIAL & BUSINESS DISTRICTS
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
1. TRAFFIC CONTROL SHALL FOLLOW THE LATEST EDITION OF THE MUTCD. ALL BARRICADES, SIGNS AND FLAGGING SHALL CONFORM TO THE REQUIREMENTS OF THE MUTCD AND WSDOT DESIGN MANUAL FOR IN-STREET WORK. FOR MORE SPECIFIC REQUIREMENTS FOR BARRICADES, SEE WSDOT STANDARD
SPECIFICATIONS.
2. SIGNS MUST BE LEGIBLE AND VISIBLE AND SHOULD BE REMOVED AT THE END OF EACH WORK DAY IF
NOT APPLICABLE AFTER CONSTRUCTIONS HOURS.
3. ALL SIGNS SHALL BE 36" X 36", UNLESS OTHERWISE SHOWN. ALL SIGNS SHALL BE BLACK ON ORANGE, UNLESS OTHERWISE NOTED IN THESE PLANS.
4. SIGN SPACING SHOWN ON THE PLANS MAY BE ADJUSTED IN THE FIELD TO ACCOMMODATE
INTERSECTIONS, DRIVEWAYS, VISIBILITY AND OTHER FEATURES.
5. ALL SIGNS NOT MOUNTED ON BARRICADES MAY BE MOUNTED ON TRIPODS IF CLEARLY VISIBLE TO TRAFFIC AND PROVIDED THEY DO NOT OBSTRUCT THE MINIMUM WIDTH OF THE PEDESTRIAN ROUTE.
OTHERWISE SIGNS SHALL BE MOUNTED ON 4"x4" WOOD POSTS. THE MINIMUM HEIGHT, MEASURED
VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE SIDEWALK, OF SIGNS INSTALLED ABOVE
SIDEWALKS SHALL BE SEVEN (7) FEET.
6. PLANS SHOW MINIMUM SIGNAGE TO DIRECT VEHICULAR TRAFFIC AROUND THE CONSTRUCTION AREA.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL ADDITIONAL
SIGNAGE AND OTHER DEVICES NECESSARY TO SAFELY DIRECT VEHICULAR AND PEDESTRIAN TRAFFIC
THROUGH AND AROUND THE CONSTRUCTION AREAS AS NECESSARY TO ACCOMMODATE
CONSTRUCTION ACTIVITIES.
7. ROAD WORK AHEAD SIGNS SHALL BE INSTALLED ON ALL SIDE STREETS AND ALLEYS WHEN TRAFFIC
CONTROL CROSSES THEM.
8. CONTRACTOR TO COVER EXISTING SIGNS IN CONFLICT WITH THIS PLAN.
9. ALL CHANNELIZATION DEVICES SHALL BE CONES OR TUBULAR MARKERS UNLESS OTHERWISE
SPECIFIED. BARRELS ARE ALLOWED PENDING APPROVAL FROM THE COUNTY ENGINEER.
10. EXTEND CHANNELIZING DEVICE TAPER ACROSS SHOULDER, WHERE APPLICABLE.
11. TAPERS MAY CROSS DRIVEWAYS BUT MAY NOT CROSS INTERSECTING ROADWAYS.
12. ADJACENT DRIVEWAYS SHALL REMAIN OPEN UNLESS OTHERWISE COORDINATED WITH RESIDENTS.
13. CONTRACTOR SHALL STAGE WORK TO MAINTAIN ACCESS TO AND EGRESS FROM ALL PROPERTIES AT ALL TIMES, UNLESS OTHERWISE SPECIFIED. AT NO TIME SHALL A COMPLETE CLOSURE BE ALLOWED
UNLESS OTHERWISE SPECIFIED OR EXPRESS PERMISSION PROVIDED BY THE ENGINEER.
14. A MINIMUM 48" WIDE PEDESTRIAN ROUTE SHALL BE MAINTAINED AT ALL TIMES ON EXISTING
SIDEWALKS THAT REMAIN OPEN, OR AN EQUIVALENT DETOUR ROUTE SHALL BE PROVIDED IN
ACCORDANCE WITH WSDOT FIELD GUIDE FOR ACCESSIBLE PUBLIC RIGHT OF WAY. A DEDICATED
FLAGGER SHALL ESCORT PEDESTRIANS AS NEEDED FOR SAFETY THROUGH THE WORK AREA.
15. WHEN TRAFFIC IS DIRECTED ONTO GROOVED PAVEMENT, OVER AN ABRUPT BUMP OR NEXT TO AN
ABRUPT LANE EDGE, THE W21-1701 SIGN SHALL BE USED TO WARN MOTORCYCLES OF THE
CONDITIONS.
16. A PROTECTIVE WORK VEHICLE MAY BE USED TO PROTECT THE WORK AREA WHERE SPEEDS ARE 40
MPH OR LESS.
17. CONTACT AND COORDINATE LOCAL AGENCIES INCLUDING EMERGENCY SERVICES, BUSINESSES AND
RESIDENTS PRIOR TO IMPLEMENTATION OF ANY CLOSURES.
18. CONTRACTOR TO INSTALL PORTABLE CHANGEABLE MESSAGE SIGN (PCMS) AT LEAST 1 WEEK PRIOR
TO BRIDGE WORK.
LEGEND
TEMPORARY SIGN LOCATION
TEMPORARY CHANNELIZING DEVICE
PROTECTIVE VEHICLE
FLAGGER
PV
WORK AREA
TYPE 2 BARRICADE WITH SIGN
DRIVEWAY
TYPE 3 BARRICADE WITH SIGN
EXISTING SIGN LOCATION
NOTES:
STAGING AREA
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
HINING ROAD MP 0.23
TRAFFIC CONTROL LEGEND
TC-01
09 11
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
11/18/2026
PCMS PORTABLE CHANGEABLE MESSAGE SIGN (PCMS)
ONLY
P C
M S
P C M S
BRIDGE
CLOSED
ONLY
DETOUR
AHEAD
ROAD
WORK
AHEAD
ROAD CLOSED
LOCAL TRAFFIC ONLY
0.5 MILES AHEAD
DETOUR
ROAD
WORK
AHEAD
DETOUR
ROAD CLOSED
LOCAL TRAFFIC ONLY
0.75 MILES AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
SEE MIDDLE BELOW FOR
TRAFFIC CONTROL FOR
HINING RD BRIDGE
MAINTENANCE
HINING RD
(25 M.P.H.)
40 80
SCALE IN FEET
RUSSELL RD
(35 M.P.H.)
HINING RD
(35 M.P.H.)
WINLOCK VADER HWY
(50 M .P.H.)
SW KERRON ST(25 M.P.H.)
SEE MIDDLE ABOVE FOR
TRAFFIC CONTROL FOR
HINING RD BRIDGE
MAINTENANCE
NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
SEE DETOUR MAP ON SHEET TC-03
SW
CA
NY
ON
LO
OP
(2
M .P
.H
SW KERRON ST
(25 M.P.H.)
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE PRIOR TO
START OF WORK
B R I D G E
C L O S U R E D A T E T O
D A T E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
BRIDGE CLOSURE
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
SEE RIGHT FOR
TRAFFIC CONTROL AT SW
CANYON LOOP, KERRON ST,
AND SW HINING ST
SEE LEFT FOR
TRAFFIC CONTROL AT
HINING RD AND RUSSEL
RD NEAR WINLOCK
VADER HWY
PROVIDE FLAGGER ASSISTANCE FOR LOCAL
DRIVEWAY INGRESS.EGRESS DURING DAYTIME
WORK HOURS, AS NEEDED
SW HINING ST
(25 M.P.H.)
HINING RD
(35 M.P.H.)
PCMS LOCATION SHOWN IS APPROXIMATE AND SHALL BE ADJUSTED IN THE FIELD BY THE CONTRACTOR.*
STAGING AREA
HINING ROAD MP 0.23
TC-02
10 11
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
ROAD CLOSED
LOCAL TRAFFIC ONLY
0.5 MILES AHEAD
DETOUR
DETOUR
ROAD CLOSED
LOCAL TRAFFIC ONLY
0.75 MILES AHEAD
END
DETOUR
DETOUR
BRIDGE
CLOSED
DETOUR
END
DETOUR
HINING RD
SE
FR
ON
T S
T
SE
FR
ON
T S
T
SE
1S T S
T
N
FE
RR
IER
R D
WINLO
CK V
AD
ER
HWY
WORK AREA
DETOUR MAP
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
BRIDGE DETOUR
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
RA
ILW
AY
40 80
SCALE IN FEET
NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
SW
C
AN
YO
N
LO
OP
SW KERRON ST
HINING ROAD MP 0.23
TC-03
11 11
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
| HINING MP 0.23 COVER SHEET - VICINITY MAP-COVER SHEET |
| COVER SHEET |
| LCPS-2199-COVER SHT-GC-GEN NOTES |
| GC-GEN NOTES |
| LCPS-2199-SP PLANS-HINING MP 0.23 |
| HINING MP 0.23 |
| LCPS-2199-BRIDGE PLANS-HINING MP 0.23 |
| HINING MP 0.23 |
| LCPS-2199-BRIDGE DETAILS-ABUTMENT REPAIR DETAILS |
| ABUTMENT REPAIR DETAILS |
| LCPS-2199-BRIDGE DETAILS-GIRDER REPAIR DETAILS |
| GIRDER REPAIR DETAILS |
| LCPS-2199-BRIDGE DETAILS-CFRP GIRDER REHABILITATION DETAILS |
| CFRP GIRDER REHABILITATION DETAILS |
| LCPS-2199-BRIDGE DETAILS-CR-BC05 |
| CR-BC05 |
File details come from the government source that posted it. Updated .