This is a technical design and construction document package for the Lewis County Preventative Bridge Maintenance Project (CRP 2199) located on Galvin Road at mile post 1.23 in Washington State. The project encompasses concrete deck repair, polyester polymer concrete (PPC) overlay installation, and expansion joint replacement on an existing bridge structure consisting of 10 spans totaling 304 feet. Work includes removal and repair of concrete spalls and delaminations, with repairs classified as Type 1 (partial depth) or Type 2 (full depth) based on damage severity. The project will be executed in two phases with one lane closed during each phase to maintain traffic flow, utilizing traffic control measures including portable changeable message signs, temporary traffic signals, cones, and flaggers. Sealed bids are due by 12:15 PM Pacific Time on Thursday, December 17, 2026, with public opening at Lewis County Courthouse in Chehalis, Washington. Bidders may submit electronically through the procurement portal or deliver physical sealed bids to the Clerk of the Board of Lewis County Commissioners. Site preparation includes erosion and sediment control measures, with all work to be contained within designated project limits within the FEMA-mapped 100-year floodplain.
Bid proposal deposits equal to five percent (5%) of the bid amount are required in cash, certified check, cashier's check, or surety bond. The successful bidder must enter into a contract and provide satisfactory contract bond within the timeframe specified, with failure to do so resulting in forfeiture of the bid deposit to Lewis County Public Works Department. Contract documents, including maps, plans, and specifications, are available on Lewis County's website at www.lewiscountywa.gov or through the Lewis County Engineers office at (360) 740-1123 Extension 2. The contact person for the project is Vince Hall, Assistant County Engineer, at (360) 740-2762 or vince.hall@lewiscountywa.gov. No specific set-asides, incumbent information, or funding sources are identified in the technical documents provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Preventative_Bridge_Maintenance_Project.pdf | ||
| BridgePreventativeMaintenance_cleanFINAL.pdf | ||
| BC00-H~1.PDF | ||
| BB00-G~1.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IDENTIFIES SECTION OR VIEW
LETTER
SHEET NUMBER WHERE SECTION OR
VIEW IS SHOWN
IDENTIFIES DETAIL NUMBER
DASH INDICATES SECTION, VIEW, OR
DETAIL IS TAKEN AND SHOWN ON THE
SAME SHEET
LEGEND
A B-08
A
ABBREVIATIONS:
AP ANGLE POINT
AVE AVENUE
BFE BASE FLOOD ELEVATION
BMP BEST MANAGEMENT PRACTICE
CL & L CENTERLINE
CY CUBIC YARD
DIA DIAMETER
DWG DRAWING
E EAST/EASTING
EL & ELEV ELEVATION
ESC EROSION AND SEDIMENT CONTROL
FT & ' FEET
HMA HOT MIX ASPHALT
IN & " INCHES
LF LINEAR FOOT
LS LUMP SUM
LT LEFT
MAX MAXIMUM
MIN MINIMUM
MUTCD MANUAL OF UNIFORM TRAFFIC
CONTROL DEVICES
N NORTH/NORTHING
OHU OVERHEAD UTILITY
OHW ORDINARY HIGH WATER MARK
PPC POLYESTER POLYMER CONCRETE
R RADIUS
RD ROAD
R/W & ROW RIGHT OF WAY
RT RIGHT
S SOUTH
SEC SECTION
STA STATION
SY SQUARE YARD
TESC TEMPORARY EROSION AND
SEDIMENT CONTROL
TC TRAFFIC CONTROL
TYP TYPICAL
W WEST
WSDOT WASHINGTON STATE DEPARTMENT
OF TRANSPORTATION
C
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9- C
O
VE
R S
H T.
dw g
/1
8/
:0
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
GALVIN ROAD MP 1.23 G-02
02 15
NN
DJ
JK
12/01/2025
G-02 - GENERAL NOTES AND
ABBREVIATIONS
Nnn Signature - Nick
MAG
S
PIKE
PLS
GR
GR
GR
GRGR GRGRGR
GR
GR
GR
GR
GR
GRGRGRGRGRGRGRGRGRGRGR
GR
GR
GR
GRGRGRGRGRGRGRGRGRGRGRGR
GRGRGR
GR
X X
X
XXXX
XXXXX
XXXXXXXXXXX
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
XXXXXXXXXXXX
X X X X X X X X X X X X X X X X X
HTK
HTK
+0
B O
P
9+
.3
P C
1+
.3
P T
3+
.3
P C
0+
.7
PP
PP
PP
TOE
TO
E
TOE
TOE
TOE TOE
TOE
TOE
TOP
TOP
TOP TOP TOP TOP TOP TOP
TOP
X X X X X X X X X X X X X X X X X X X X X X X X
OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHU
170169
PLAN
STAGING AREA
GALVIN ROAD
MP 1.23 BRIDGE
SHORELINE
ENVIRONMENT
PROJECT
LIMITS
ROW
ROW
LEGEND
STAGING AREA
STABILIZED CONSTRUCTION ENTRANCE PER
WSDOT STD. PLAN I-80.10-02
SHORELINE ENVIRONMENT
PROJECT LIMITS
INLET PROTECTION - SEE WSDOT STD SPEC
SECTION 8-01.3(9)D
ALL PROJECT LIMITS ARE WITHIN FEMA
MAPPED 100-YR FLOODPLAIN
40 0 40 80
57 WEST MAIN ST
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
SP
P
LA
N S.
dw g
/1
8/
:1
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
GALVIN ROAD MP 1.23 G-03
03 15
CHED
CHED
JJ
06/01/2026 G-03 - SITE PREP & TESC PLAN
INLET PROTECTION (TYP.)
EROSION AND SEDIMENT CONTROL NOTES:
1. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED PRIOR TO OR IN CONJUNCTION WITH GRADING SO AS TO ENSURE THAT THE
TRANSPORT OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS, AND ADJACENT PROPERTIES IS PREVENTED.
2. THE ESC FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR THE ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND MODIFIED TO ACCOUNT
FOR CHANGING SITE CONDITIONS.
3. ALL GRADING SHALL BE CONTAINED WITHIN THE LIMITS ESTABLISHED BY THE ENGINEER. ALL VEGETATION OUTSIDE DESIGNATED LIMITS SHALL
REMAIN UNDISTURBED.
4. ALL STOCKPILES ARE TO BE LOCATED IN SAFE AREAS AND PROTECTED FROM EROSION.
5. ALL EXPOSED AND UNWORKED SOILS SHALL BE STABILIZED BY SEEDING, MULCHING, MATTING, OR PLASTIC COVERING. FROM OCT. 1 TO APRIL 30, NO SOILS SHALL REMAIN UNSTABILIZED FOR MORE THAN 2 DAYS. FROM MAY 1 TO SEPT. 30, NO SOILS SHALL REMAIN UNSTABILIZED FOR MORE
THAN 7 DAYS.
6. ALL POLLUTANTS OTHER THAN SEDIMENTS THAT OCCUR ON-SITE DURING CONSTRUCTION SHALL BE HANDLED AND DISPOSED OF IN A MANNER THAT DOES NOT CAUSE CONTAMINATION OF STORMWATER PER CURRENT VERSION OF DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT
MANUAL.
7. SEDIMENTS TRANSPORTED ONTO A ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM ROADS BY SHOVELING OR SWEEPING AND BE TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. ALL COSTS ASSOCIATED WITH THIS WORK SHALL BE INCIDENTAL TO THE VARIOUS
BID ITEMS.
8. NO GROUND DISTURBANCE SHALL TAKE PLACE IN STAGING AREA.
GR
GR
GRGR
GRGR
GRGR
XXXX
X
X
X
HTK
HTK
P T
3+
.3
PP
PP
TOP
X X X
OHUOHUOHUOHUOHUOHUOHU
LA
N
E
LA
N E
R O
AD
W
AY
SD
W
K
EXPANSION JOINT
@ PIERS 3, 5, 7 & 9
EXIST BRIDGE DRAIN
(TYP) TOTAL 10
L PIER 2C
PIER 1
BACK OF END WALL
L PIER 3C L PIER 4C L PIER 5C L PIER 6C L PIER 7C L PIER 8C L PIER 9C L PIER 10C
PIER 11
BACK OF END WALL
GALVIN ROAD
FACE OF BARRIER
FACE OF CURB
REPLACE EXPANSION
JOINT @ PIER 11
GENERAL SPALL GENERAL SPALL CONCRETE
DECK REPAIR
SPALL WITH
DELAMINATON IN
PIER 11 JOINT HEADER
CONCRETE
DECK REPAIR
'-0
"± 14 '-0
'-0
5' -0
REPLACE EXPANSION
JOINT @ PIER 1
39'-01
2"± 8 SPANS @ 38'-0"± = 304'-0"± 39'-01
2"±
382'-1"± BACK TO BACK OF END WALLS
SEE "CONCRETE REPAIR DETAILS" SHEET FOR GENERAL
SPALL/DELAMINATION AND DECK REPAIR DETAILS
PLAN
PROFILE GRADE
& PIVOT POINT
14'-0"±
L GALVIN ROADC
-0.02'±/FT
14'-0"±
33'-0"±
-0.02'±/FT
5'-0"±
LANE LANE SIDEWALK
PROPOSED 3 4"
PPC OVERLAY
EXIST GLU-LAM
TIMBER (TYP)
EXIST TIMBER
PILE (TYP)
SEE DETAIL 1
BOTTOM OF DECK EL
RANGE: 168.45 TO 170.37
BOTTOM OF CROSS BEAM
EL RANGE: 165.21 TO 167.18
FEMA 100-YR
BFE 165.4
4"
PP
C
O
VE
R
LA
Y
1 4" 1 2"
TOP OF PPC OVERLAY
EXIST DECK
SC
AR
IF
IC
AT
IO
N
DETAIL 1
14'-0"±
L GALVIN ROADC
12'-0"
33'-0"±
5'-0"±
WORK AREA LANE OPEN TO TRAFFIC SIDEWALK
2'-0"
MAX
14'-0"±
L GALVIN ROADC
12'-0"
33'-0"±
5'-0"±
WORK AREALANE OPEN TO TRAFFIC SIDEWALK
2'-0"
MAX
-0.02'±/FT
-0.02'±/FT
28" TRAFFIC CONE
(SEE TC PLANS)
28" TRAFFIC CONE
(SEE TC PLANS)
TYPICAL BRIDGE SECTION
LIMITS OF DECK GRINDING AND POLYESTER
POLYMER CONCRETE (PPC) OVERLAY
LEGEND
1. PERFORM CONCRETE DECK REPAIR.
2. APPLY PPC OVERLAY.
3. ALL WORK SHALL BE COMPLETED IN TWO
PHASES. ONE LANE SHALL BE CLOSED DURING
EACH PHASE TO ALLOW REPAIR AND OVERLAY
OF THE OPPOSITE LANE.
WORK DESCRIPTION
STAGE 1 - TYPICAL SECTION
STAGE 2 - TYPICAL SECTION
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E
PL
AN
S.
dw g
/1
8/
:1
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
GALVIN ROAD MP 1.23 B-01
04 15
NN
DJ
JK
12/01/2025
B-01 - BRIDGE LAYOUT AND TYPICAL
SECTION
DATUM
NAVD 1988
D. S. BROWN
WIDTH
WATSON BOWMAN
ACME
CV-2502 WA-250
SEAL SEAL WIDTH
TESTING SHALL BE PER ASTM D 2628 PRIOR TO USE
1½" INSTALLATION WIDTH IN ROADWAY,
SIDEWALK & TRAFFIC BARRIER FOR 2½"
COMPRESSION SEAL SIZE
TOP OF EXIST DECK
USE 3 8" EDGER
REMOVE EXISTING COMPRESSION
SEAL, BLAST CLEAN EXISTING
CONCRETE SURFACES, INSTALL
NEW SEAL PER MANUFACTURER'S
RECOMMENDATIONS
BRIDGEBRIDGE APPROACH
2½" 2½"
COMPRESSION SEAL TABLE
DRILL ½"Ø HOLE THRU SEAL.
MAKE SURE THE TOP MEMBRANE
IS NOT DAMAGED WHEN CUTTING
OUT THE WEDGE
¼" THICK SYNTHETIC CLOSED CELL
EXPANDED RUBBER JOINT FILLER
CEMENTED TO JOINT SEAL AT END
0° CORNER "A"
45° CORNER "B"
COMPRESSION SEAL
H
3 H
FULLY COMPRESSED SEAL HEIGHT,
SEAL HEIGHT VARIES WITH
MANUFACTURER, GRIND LOWER LEDGE
AS REQUIRED FOR INSTALLATION
NEW COMPRESSION SEAL
PLACED AFTER APPLICATION
OF NEW OVERLAY
SEE SHEET B-03 FOR "GENERAL
SPALL/DELAMINATION DETAIL"
MAINTAIN EXISTING REINF OR
REPLACE IN-KIND SET IN EPOXY
RESIN W/ 3" MIN EMBEDMENT
SAWCUT AND SEAL ASPHALT
BUTT JOINT PER STANDARD
PLAN A-40.20-04 DETAIL 3
HMA TRANSITION
PER STANDARD
PLAN A-60.30-01
TOP OF HEADER LEVEL WITH
TOP OF EXISTING DECK 1 4"
4" PPC OVERLAY
M
AX
2" SCARIFICATION
CURB
CORNER "A"
CORNER "A"
TOP OF SIDEWALKCORNER "B"
TOP OF ROADWAY
CURB
CORNER "A"
COMPRESSION SEAL
COMPRESSION SEAL DETAIL
(MODIFIED CONDITION)
SEAL CUTTING DETAIL COMPRESSION SEAL INSTALLATION AT CURBS DETAILS
SEE "SEAL CUTTING DETAIL"
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E D
ET
AI
LS
.d w g
/1
8/
:2
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
GALVIN ROAD MP 1.23 B-02
05 15
NN
DJ
JK
12/01/2025 B-02 - EXPANSION JOINT DETAILS
TYPE 2 DECK REPAIR
REMOVE ALL CONCRETE FULL
DEPTH AS SHOWN ON THE
PLANS AND AS REQUIRED BY
THE ENGINEER.
REPLACE EXISTING
REINFORCEMENT
WITH GREATER THAN
25% SECTION LOSS
PRESERVE AND CLEAN
REINFORCING STEEL WITH
LESS THAN 25% SECTION LOSS
PARTIAL DECK REPAIR DETAIL
GENERAL SPALL/DELAMINATION REPAIR DETAIL
1/4" TAPCON SCREWS, OR
APPROVED EQUAL. 6" MAX
SPACING, STAGERED, NOT
TO CONFLICT WITH EXIST
REINFORCEMENT. WOVEN
REINFORCED TIE WIRE NOT
SHOWN FOR CLARITY (TYP)
GENERAL CONCRETE
SPALL/DELAMINATION
FULL DEPTH DECK REPAIR DETAIL
EXISTING REINFORCEMENT
REPLACE EXISTING
REINFORCEMENT WITH
GREATER THAN 25%
SECTION LOSS
FULL DEPTH DECK REPAIR AREA.
PARTIAL DECK REMOVAL DETAIL
INTENTIONALLY
ROUGHEN SURFACE (TYP)
EXISTING BOTTOM
MAT REINFORCING
3/4" SAWCUT AT
EDGE OF REPAIR
AREA
SECTION A
SECTION B
PROTECT EXISTING
REINFORCING STEEL
1/4" TAPCON SCREW (TYP)
APPLY BONDING AGENT
TO ALL CONCRETE
REINFORCING SURFACES
REMOVE LOOSE CONCRETE
TO SOUND CONCRETE
SAWCUT 3/4" MAX
CLEAN AND COAT EXISTING REINFORCING
AND CONCRETE SURFACE WITH
CORROSION INHIBITOR (SIKA ARAMETEC
110 OR APPROVED EQUAL IF REQUIRED)
SAWCUT 3/4" MIN.
ALL EDGES (TYP)
REMOVE CONCRETE
TO PROVIDE 3/4" MIN
CLEARANCE
(OVERLAY NOT SHOWN FOR CLARITY)
(OVERLAY NOT SHOWN FOR CLARITY)
3/4" MAX SAW CUT
EXISTING TOP MAT
OF REINFORCING
TYPE 1 DECK REPAIR
TOP OF DECK
MID HEIGHT OF EXISTING TOP MAT
BOTTOM BAR, AREAS WHERE CONCRETE
IS REMOVED BELOW THIS LINE REQUIRE
TYPE 2 DECK REPAIRS. REPAIRS ABOVE
THIS LINE REQUIRE TYPE 1 DECK REPAIRS
(IF REQUIRED)
(IF REQUIRED)
A
B
TYPE 2 DECK REPAIRTYPE 1 DECK REPAIR
MATCH CONCRETE
OVERLAY CLASS M CONCRETE
GENERAL NOTES
1. THESE DETAILS REFLECT THE SCOPE AND THE NATURE OF THE WORK. THEY ARE NOT INTENDED TO REPRESENT THE ACTUAL
STRUCTURE.
2. BID ITEM QUANTITIES ARE ESTIMATES. ACTUAL CONCRETE SPALL AND REPAIR WILL BE AS NEEDED TO REACH SOUND
CONCRETE SUBSTRATE OR AS DIRECTED BY THE ENGINEER.
3. REMOVAL OPERATIONS SHALL BE COORDINATED WITH THE ENGINEER AND PERFORMED IN A MANNER AS REQUIRED TO
ENSURE THE STRUCTURAL INTEGRITY OF THE BRIDGE.
4. ALL DAMAGED OR CORRODED NON-EPOXY COATED REINFORCING STEEL REQUIRES NEW NON-EPOXY COATED REINFORCING STEEL TO BE ADDED. ALL EXPOSED NON-EPOXY COATED REINFORCING STEEL SHALL BE CLEANED WITH HAND TOOLS, STRAIGHTENED AND SANDBLASTED PRIOR TO PLACING CONCRETE.
5. OVERLAID DECK MAY BE OPENED TO TRAFFIC AS SOON AS NEW CONCRETE HAS ATTAINED REQUIRED STRENGTH.
6. INTENTIONALLY ROUGHEN ALL CONCRETE SURFACES RECEIVING REPAIR TO AN AMPLITUDE OF 1/4".
7. CONCRETE REPAIR SCREWS SHALL BE TAPCON, OR APPROVED EQUAL, SCREWS SHALL BE EMBEDED INTO SOUND CONCRETE
A MINIMUM OF 2". INSTALL PER MANUFACTURERS RECOMMENDATIONS. SCREWS ARE REQUIRED WHERE SHOWN IN THE DETAILS AND WHERE 1" CLEAR BEHIND REINFORCING IS NOT ACHIEVABLE. SCREWS WILL NOT BE MEASURED AND PAID FOR
SEPARATELY BUT SHALL BE INCLUDED IN CONCRETE REPAIR BID ITEM.
8. WEAVE 16 GAGE REINFORCING TIE WIRE, ASTM A1064 BETWEEN SCREWS TO FORM SPIDERWEB BETWEEN SCREWS. WIRE WILL NOT BE MEASURED AND PAID FOR SEPARATELY, BUT SHALL BE INCIDENTAL TO CONCRETE REPAIR BID ITEM.
9. REMOVE RUST AND DEBRIS FROM ALL EXPOSED REINFORCEMENT. CONTRACTOR SHALL SPLICE AND REPLACE
REINFORCEMENT AS NEEDED.
10. PROTECT EXISTING REINFORCING IN PLACE. CONTRACTOR SHALL NOTIFY THE ENGINEER IF REINFORCING IS DAMAGED.
11. PROVIDE A MINIMUM OF 1" CLEAR BETWEEN REINFORCING AND PREPARED SURFACE.
12. ALL SURFACES SHALL RECEIVE AN EPOXY CONCRETE BINDER PRIOR TO PLACING CONCRETE. EPOXY BINDER SHALL BE SIKA ARMATECK - 100 EPOCEM OR APPROVE EQUAL. BINDER IS INCIDENTAL TO CONCRETE REPAIR BID ITEM.
13. ALL CAST-IN-PLACE CONCRETE SHALL BE CLASS 4000D FOR CONCRETE DECKS AND CLASS 4000 FOR ALL OTHER CONCRETE.
14. UNLESS OTHERWISE SHOWN IN THE PLANS, CONCRETE COVER MEASURED FROM THE FACE OF CONCRETE TO THE FACE OF
ANY REINFORCING STEEL SHALL BE 2".
15. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3 4", UNLESS NOTED OTHERWISE.
16. REINFORCING BARS SHALL CONFORM TO ASTM A706 GRADE 60 UNLESS OTHERWISE NOTED. THE MINIMUM LAP SPLICE FOR
REINFORCING BARS SHALL BE AS SHOWN IN THE TABLE BELOW.
BAR SIZES:
SPLICE LENGTH (TOP BARS):
#4
2'-0"
#5
2'-7"
#6
3'-1"
#7
3'-7"
#8
4'-1"
SPLICE LENGTH (EPOXY COATED):
2'-0" 2'-4" 2'-9" 3'-2"
TOP BARS ARE HORIZONTAL BARS PLACES SUCH THAT MORE THAN 12" OF CONCRETE IS CAST BELOW REINFORCEMENT.
5'-2" 6'-5" 7'-8" 8'-11" 10'-3"
1'-3"SPLICE LENGTH (OTHERS):
GENERAL SPALL REPAIR DETAIL APPLIES TO BOTH
HORIZONTAL AND VERTICAL SURFACES. VERTICAL
SURFACE DETAIL SHOWN; OTHERS SIMILAR.
KEY NOTES:
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
REVISION
"It's the Law"
1-800-
BEFORE YOU DIG
CALL 48 HOURS
424-5555
Utilities Underground
Location Center
P:
\L
\L C
PS
\0
0C
AD
\S
H
EE
TS
\L
C
PS
-2
9-
BR
ID
G
E D
ET
AI
LS
.d w g
/1
8/
:2
PM
14432 SE Eastgate Way, Suite 400 Bellevue, WA 98007
425.519.6500
REFERENCE SHEET NO.
SHEET NO.OF TOTAL
IH N
TON
G
WAOF
TAS
TE
S
E
IN
RE
NE G
D ER
STGE
OSI
I
P
OFE
R R
S
NAL
E
21020015
RU
OPKINNKCIN
11/18/2026
GALVIN ROAD MP 1.23 B-03
06 15
NN
DJ
JK
12/01/2025 B-03 - CONCRETE REPAIR DETAILS
MINIMUM LANE CLOSURE TAPER LENGTH = L (feet)
LANE
WIDTH
(feet)
Posted Speed (mph)
CHANNELIZATION DEVICE
SPACING (feet)
SHOULDER
WIDTH
(feet)
Posted Speed (mph)
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
USE A MINIMUM OF 3 DEVICES TAPER
FOR SHOULDER LESS THAN 8'
LONGITUDINAL BUFFER SPACE = B
BUFFER DATA
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 lbs.
HOST VEHICLE WEIGHT
> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS
URBAN STREETS
RURAL HIGHWAYS
FREEWAYS & EXPRESSWAYS
SIGN SPACING = X (1)
RURAL ROADS & URBAN ARTERIALS
RESIDENTIAL & BUSINESS DISTRICTS
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
ROADWAY CONDITIONS.
1. TRAFFIC CONTROL SHALL FOLLOW THE LATEST EDITION OF THE MUTCD. ALL BARRICADES, SIGNS AND FLAGGING SHALL CONFORM TO THE REQUIREMENTS OF THE MUTCD AND WSDOT DESIGN MANUAL FOR IN-STREET WORK. FOR MORE SPECIFIC REQUIREMENTS FOR BARRICADES, SEE WSDOT STANDARD
SPECIFICATIONS.
2. SIGNS MUST BE LEGIBLE AND VISIBLE AND SHOULD BE REMOVED AT THE END OF EACH WORK DAY IF
NOT APPLICABLE AFTER CONSTRUCTIONS HOURS.
3. ALL SIGNS SHALL BE 36" X 36", UNLESS OTHERWISE SHOWN. ALL SIGNS SHALL BE BLACK ON ORANGE, UNLESS OTHERWISE NOTED IN THESE PLANS.
4. SIGN SPACING SHOWN ON THE PLANS MAY BE ADJUSTED IN THE FIELD TO ACCOMMODATE
INTERSECTIONS, DRIVEWAYS, VISIBILITY AND OTHER FEATURES.
5. ALL SIGNS NOT MOUNTED ON BARRICADES MAY BE MOUNTED ON TRIPODS IF CLEARLY VISIBLE TO TRAFFIC AND PROVIDED THEY DO NOT OBSTRUCT THE MINIMUM WIDTH OF THE PEDESTRIAN ROUTE.
OTHERWISE SIGNS SHALL BE MOUNTED ON 4"x4" WOOD POSTS. THE MINIMUM HEIGHT, MEASURED
VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE SIDEWALK, OF SIGNS INSTALLED ABOVE
SIDEWALKS SHALL BE SEVEN (7) FEET.
6. PLANS SHOW MINIMUM SIGNAGE TO DIRECT VEHICULAR TRAFFIC AROUND THE CONSTRUCTION AREA.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL ADDITIONAL
SIGNAGE AND OTHER DEVICES NECESSARY TO SAFELY DIRECT VEHICULAR AND PEDESTRIAN TRAFFIC
THROUGH AND AROUND THE CONSTRUCTION AREAS AS NECESSARY TO ACCOMMODATE
CONSTRUCTION ACTIVITIES.
7. ROAD WORK AHEAD SIGNS SHALL BE INSTALLED ON ALL SIDE STREETS AND ALLEYS WHEN TRAFFIC
CONTROL CROSSES THEM.
8. CONTRACTOR TO COVER EXISTING SIGNS IN CONFLICT WITH THIS PLAN.
9. ALL CHANNELIZATION DEVICES SHALL BE CONES OR TUBULAR MARKERS UNLESS OTHERWISE
SPECIFIED. BARRELS ARE ALLOWED PENDING APPROVAL FROM THE COUNTY ENGINEER.
10. EXTEND CHANNELIZING DEVICE TAPER ACROSS SHOULDER, WHERE APPLICABLE.
11. TAPERS MAY CROSS DRIVEWAYS BUT MAY NOT CROSS INTERSECTING ROADWAYS.
12. ADJACENT DRIVEWAYS SHALL REMAIN OPEN UNLESS OTHERWISE COORDINATED WITH PROPERTY
OWNERS AND TENANTS.
13. CONTRACTOR SHALL STAGE WORK TO MAINTAIN ACCESS TO AND EGRESS FROM ALL PROPERTIES AT ALL TIMES, UNLESS OTHERWISE SPECIFIED. AT NO TIME SHALL A COMPLETE CLOSURE BE ALLOWED
UNLESS OTHERWISE SPECIFIED OR EXPRESS PERMISSION PROVIDED BY THE ENGINEER.
14. A MINIMUM 48" WIDE PEDESTRIAN ROUTE SHALL BE MAINTAINED AT ALL TIMES ON EXISTING
SIDEWALKS THAT REMAIN OPEN, OR AN EQUIVALENT DETOUR ROUTE SHALL BE PROVIDED IN
ACCORDANCE WITH WSDOT FIELD GUIDE FOR ACCESSIBLE PUBLIC RIGHT OF WAY. A DEDICATED
FLAGGER SHALL ESCORT PEDESTRIANS AS NEEDED FOR SAFETY THROUGH THE WORK AREA.
15. WHEN TRAFFIC IS DIRECTED ONTO GROOVED PAVEMENT, OVER AN ABRUPT BUMP OR NEXT TO AN
ABRUPT LANE EDGE, THE W21-1701 SIGN SHALL BE USED TO WARN MOTORCYCLES OF THE
CONDITIONS.
16. A PROTECTIVE WORK VEHICLE MAY BE USED TO PROTECT THE WORK AREA WHERE SPEEDS ARE 40
MPH OR LESS.
17. CONTACT AND COORDINATE LOCAL AGENCIES INCLUDING EMERGENCY SERVICES, BUSINESSES AND
RESIDENTS PRIOR TO IMPLEMENTATION OF ANY CLOSURES.
18. CONTRACTOR TO INSTALL PORTABLE CHANGEABLE MESSAGE SIGN (PCMS) AT LEAST 1 WEEK PRIOR
TO BRIDGE WORK AND MAINTAIN THE SIGNS THROUGHOUT THE DURATION OF THE PROJECT.
19. PORTABLE TEMPORARY TRAFFIC SIGNALS SHALL BE USED TO CONTROL ONE-LANE, TWO-WAY TRAFFIC
DURING 24-HOUR SINGLE-LANE CLOSURES ASSOCIATED WITH CONCRETE CURE OPERATIONS.
20. PORTABLE TEMPORARY TRAFFIC SIGNALS SHALL REMAIN IN OPERATION WHEN FLAGGERS ARE NOT
PRESENT, DURING NIGHT BRIDGE WORK ACTIVITIES, AND NON-WORK HOURS.
21. THESE TRAFFIC CONTROL PLANS APPLY TO SIMULTANEOUS OR INDIVIDUAL BRIDGE WORK BETWEEN
MP 1.23 AND 1.55.
LEGEND
TEMPORARY SIGN LOCATION
TEMPORARY CHANNELIZING DEVICE
PROTECTIVE VEHICLE
FLAGGER
PV
WORK AREA
TYPE 2 BARRICADE WITH SIGN
TYPE 3 BARRICADE WITH SIGN
EXISTING SIGN LOCATION
NOTES:
STAGING AREA
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
GALVIN ROAD MP 1.23
TRAFFIC CONTROL LEGEND
TC-01
07 15
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
TRAILER MOUNTED TEMPORARY TRAFFIC SIGNAL
TEMPORARY MARKING
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
PCMS PORTABLE CHANGEABLE MESSAGE SIGN (PCMS)
11/18/2026
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 20/25
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MPH
AutoCAD SHX Text 50/70
AutoCAD SHX Text 35/45
AutoCAD SHX Text 20/30
AutoCAD SHX Text
TAPER
AutoCAD SHX Text
TANGENT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 20/25
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 14'
AutoCAD SHX Text 12'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPEED (MPH)
AutoCAD SHX Text 20/25
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text LENGTH (feet)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 150'
AutoCAD SHX Text 100'
AutoCAD SHX Text 172'
AutoCAD SHX Text 123'
AutoCAD SHX Text 100'
AutoCAD SHX Text
< 45 MPH
AutoCAD SHX Text
45-55 MPH
AutoCAD SHX Text
> 55 MPH
AutoCAD SHX Text
< 45 MPH
AutoCAD SHX Text
45-55 MPH
AutoCAD SHX Text
> 55 MPH
AutoCAD SHX Text 74'
AutoCAD SHX Text 6'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
35 / 40 MPH
AutoCAD SHX Text 350' %%P
AutoCAD SHX Text
45 / 55 MPH
AutoCAD SHX Text 500' %%P
AutoCAD SHX Text
25 / 30 MPH
AutoCAD SHX Text 200' %%P (2)
AutoCAD SHX Text
25 MPH OR LESS
AutoCAD SHX Text 100' %%P (2)
AutoCAD SHX Text
60 / 65 MPH
AutoCAD SHX Text
55 / 70 MPH
AutoCAD SHX Text 800' %%P
AutoCAD SHX Text 1500' %%P
AutoCAD SHX Text 10'
AutoCAD SHX Text 8'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Flagger 1-3.dwg
AutoCAD SHX Text
11/18/2026 5:12 PM
AutoCAD SHX Text 11/18/2026
AutoCAD SHX Text 48817
ONE LANE
ROAD
AHEAD
PV
ROAD
WORK
AHEAD
BE
PREPARED
TO STOP
P C
M S
40 80
SCALE IN FEET
GALVIN RD
(35 M.P.H.)
NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
M A T C H L I N E
A A
S E E
S H E E T
T C
**SECTION A-A TYPICAL FOR THIS SETUP
APPLY IN REVERSE FOR THE OPPOSITE LANE CLOSURE
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
FLAGGER TO COMMUNICATE VIA RADIO
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE PRIOR TO
START OF WORK
W O R K
B R I D G E D A T E T O
D A T E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O N
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE DURING
CONSTRUCTION
O N E A
A H E A D D A T E L A
E X P E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O A L N E
R D C
D E Y T S
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
GALVIN ROAD MP 1.23
TC-02
08 15
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 WB LANE CLOSURE - WITH FLAGGERS (1 OF 2)
STAGING AREA
ACCESSROAD
11/18/2026
AutoCAD SHX Text
14' WORK AREA
AutoCAD SHX Text
**SECTION
AutoCAD SHX Text A-A
AutoCAD SHX Text
12' LANE OPEN TO ALT. TRAFFIC
AutoCAD SHX Text
2'MAX
AutoCAD SHX Text W20-4
AutoCAD SHX Text W20-7A
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text
12' MIN
AutoCAD SHX Text
OVERFLOW BRIDGE
AutoCAD SHX Text
100' TAPER
AutoCAD SHX Text W20-1
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-7B
AutoCAD SHX Text
180' BUFFER
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
OVERFLOW BRIDGE
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Flagger 1-3.dwg
AutoCAD SHX Text
11/18/2026 5:12 PM
AutoCAD SHX Text 11/18/2026
SPEED
LIMIT
STAY
IN
LANE
STAY
IN
LANE
PV
ROAD
WORK
AHEAD
BE
PREPARED
TO STOP
P C M S
ROAD
WORK
AHEAD
ONE LANE
ROAD
AHEAD
BE
PREPARED
TO STOP
P C M S
40 80
SCALE IN FEET
0NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
FLAGGER TO COMMUNICATE VIA RADIO
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
M A T C H L I N E
A A
S E E
S H E E T
T C
M A T C H L I N E
B B
S E E
B E L O W
L E F T
M A T C H L I N E
B B
S E E
A B O V E
R I G H T
MATCHLINE C-C -SEE RIGHT
MATCHLINE C-C -SEE LEFT
GALVIN RD
(35 M.P.H.)
GALVIN RD
(35 M .P.H.)
GALVIN RD
(35 M.P.H.)
RIVER HEIGHTS RD
(25 M .P.H
FLAGGER TO COMMUNICATE VIA RADIO
STAGING AREA
GALVIN ROAD MP 1.23
TC-03
09 15
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
WB LANE CLOSURE - WITH FLAGGERS (2 OF 2)
STAGING AREA
11/18/2026
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text R2-1
AutoCAD SHX Text R4-9
AutoCAD SHX Text R4-9
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text
RIVER BRIDGE
AutoCAD SHX Text 200'
AutoCAD SHX Text 200'
AutoCAD SHX Text 200'
AutoCAD SHX Text W20-1
AutoCAD SHX Text W20-7B
AutoCAD SHX Text W20-7A
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text W20-1
AutoCAD SHX Text W20-4
AutoCAD SHX Text W20-7A
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-7B
AutoCAD SHX Text 50'-100'
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text 60'
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Flagger 1-3.dwg
AutoCAD SHX Text
11/18/2026 5:12 PM
AutoCAD SHX Text 11/18/2026
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
BE
PREPARED
TO STOP
P C
M S
STAY
IN
LANE
PV
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
40 80
SCALE IN FEET
0NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
M A T C H L I N E
D D
S E E
S H E E T
T C
GALVIN RD
(35 M.P.H.)
FLAGGER TO COMMUNICATE VIA RADIO
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE PRIOR TO
START OF WORK
W O R K
B R I D G E D A T E T O
D A T E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O N
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE DURING
CONSTRUCTION
O N E A
A H E A D D A T E L A
E X P E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O A L N E
R D C
D E Y T S
GALVIN ROAD MP 1.23
TC-04
10 15
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 EB LANE CLOSURE - WITH FLAGGERS (1 OF 2)
STAGING AREA
ACCESSROAD
11/18/2026
AutoCAD SHX Text W20-4
AutoCAD SHX Text W20-7A
AutoCAD SHX Text
50-100 FT
AutoCAD SHX Text 12'
AutoCAD SHX Text
OVERFLOW BRIDGE
AutoCAD SHX Text
230' BUFFER
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-1
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-7B
AutoCAD SHX Text R4-9
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Flagger 4-5.dwg
AutoCAD SHX Text
11/18/2026 5:12 PM
AutoCAD SHX Text 11/18/2026
STAY
IN
LANE
PV
ROAD
WORK
AHEAD
BE
PREPARED
TO STOP
P C M S
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
BE
PREPARED
TO STOP
P C M S
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
40 80
SCALE IN FEET
0NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
M A T C H L I N E
D D
S E E
S H E E T
T C
M A T C H L I N E
E E
S E E
B E L O W
L E F T
M A T C H L I N E
E E
S E E
A B O V E
R I G H T
GALVIN RD
(35 M.P.H.)
GALVIN RD
(35 M.P.H.)
MATCHLINE F-F -SEE RIGHT
MATCHLINE F-F -SEE LEFT
GALVIN RD
(35 M.P.H.)
RIVER HEIGHTS RD
(25 M .P.H
FLAGGER TO COMMUNICATE VIA RADIOFLAGGER TO COMMUNICATE VIA RADIO
STAGING AREA
STAGING AREA
GALVIN ROAD MP 1.23
TC-05
11 15
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 EB LANE CLOSURE - WITH FLAGGERS (2 OF 2)
11/18/2026
AutoCAD SHX Text
RIVER BRIDGE
AutoCAD SHX Text R2-1
AutoCAD SHX Text R4-9
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text
322' FLAGGER TAPER
AutoCAD SHX Text 200'
AutoCAD SHX Text 200'
AutoCAD SHX Text 200'
AutoCAD SHX Text W20-1
AutoCAD SHX Text W20-7B
AutoCAD SHX Text W20-7A
AutoCAD SHX Text W20-4
AutoCAD SHX Text W20-7A
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-1
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-7B
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Flagger 4-5.dwg
AutoCAD SHX Text
11/18/2026 5:13 PM
AutoCAD SHX Text 11/18/2026
PV
P C
M S
STAY
IN
LANE
ONE LANE
ROAD
AHEADROAD
WORK
AHEAD
HERE ON
STOP
RED
40 80
SCALE IN FEET
GALVIN RD
(35 M.P.H.)
NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
M A T C H L I N E
G G S E E
S H E E T
T C
**SECTION A-A TYPICAL FOR THIS SETUP
APPLY IN REVERSE FOR THE OPPOSITE LANE CLOSURE
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE PRIOR TO
START OF WORK
W O R K
B R I D G E D A T E T O
D A T E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O N
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE DURING
CONSTRUCTION
O N E A
A H E A D D A T E L A
E X P E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O A L N E
R D C
D E Y T S
GALVIN ROAD MP 1.23
TC-06
12 15
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 WB LANE CLOSURE - TEMP. SIGNALS (1 OF 2)
STAGING AREA
ACCESSROAD
CONTRACTOR TO INSTALL TEMPORARY 18-INCH WHITE STOP BAR AT THE
LOCATION SHOWN.
TEMPORARY TRAFFIC CONTROL NOTES:
CONTRACTOR TO REFRESH THE YELLOW CENTERLINE, AS REQUIRED, FOR A
MINIMUM OF 500' ON THE APPROACH TO THE STOP BAR.
11/18/2026
AutoCAD SHX Text
14' WORK AREA
AutoCAD SHX Text
**SECTION
AutoCAD SHX Text A-A
AutoCAD SHX Text
12' LANE OPEN TO ALT. TRAFFIC
AutoCAD SHX Text
2'MAX
AutoCAD SHX Text
12' MIN
AutoCAD SHX Text
OVERFLOW BRIDGE
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text R4-9
AutoCAD SHX Text
OVERFLOW BRIDGE
AutoCAD SHX Text W20-4
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-1
AutoCAD SHX Text 350'
AutoCAD SHX Text 50'-100'
AutoCAD SHX Text R10-6
AutoCAD SHX Text W3-3
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Signal 6-7.dwg
AutoCAD SHX Text
11/18/2026 5:13 PM
AutoCAD SHX Text 11/18/2026
STAY
IN
LANE
PV
ROAD
WORK
AHEAD
HERE ON
STOP
RED
P C M S
P C M S
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
HERE ON
STOP
RED
40 80
SCALE IN FEET
0NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
M A T C H L I N E
G G
S E E
S H E E T
T C
M A T C H L I N E
H H
S E E
B E L O W
L E F T
M A T C H L I N E
H H
S E E
A B O V E
R I G H T
MATCHLINE I-I -SEE RIGHT
MATCHLINE I-I -SEE LEFT
GALVIN RD
(35 M.P.H.)
GALVIN RD
(35 M .P.H.)
GALVIN RD
(35 M.P.H.)
RIVER HEIGHTS RD
(25 M .P.H
STAGING AREA
STAGING AREA
GALVIN ROAD MP 1.23
TC-07
13 15
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 WB LANE CLOSURE - TEMP. SIGNALS (2 OF 2)
CONTRACTOR TO INSTALL TEMPORARY 18-INCH WHITE STOP BAR AT THE
LOCATION SHOWN.
TEMPORARY TRAFFIC CONTROL NOTES:
CONTRACTOR TO REFRESH THE YELLOW CENTERLINE, AS REQUIRED, FOR A
MINIMUM OF 500' ON THE APPROACH TO THE STOP BAR.
11/18/2026
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text R2-1
AutoCAD SHX Text R4-9
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text
RIVER BRIDGE
AutoCAD SHX Text 200'
AutoCAD SHX Text 200'
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text W20-1
AutoCAD SHX Text R10-6
AutoCAD SHX Text W3-3
AutoCAD SHX Text 50'
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text W20-4
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-1
AutoCAD SHX Text 350'
AutoCAD SHX Text R10-6
AutoCAD SHX Text 350'
AutoCAD SHX Text
40' TO 180'
AutoCAD SHX Text W3-3
AutoCAD SHX Text 50'
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Signal 6-7.dwg
AutoCAD SHX Text
11/18/2026 5:13 PM
AutoCAD SHX Text 11/18/2026
P C
M S
STAY
IN
LANE
PV
ONE LANE
ROAD
AHEADROAD
WORK
AHEAD
HERE ON
STOP
RED
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
40 80
SCALE IN FEET
0NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
M A T C H L I N E
J J
S E E
S H E E T
T C
GALVIN RD
(35 M.P.H.)
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE PRIOR TO
START OF WORK
W O R K
B R I D G E D A T E T O
D A T E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O N
PANEL 1 PANEL 2
2.0 SEC 2.0 SEC
MESSAGE DURING
CONSTRUCTION
O N E A
A H E A D D A T E L A
E X P E
PORTABLE CHANGEABLE
MESSAGE SIGN DETAIL
O A L N E
R D C
D E Y T S
GALVIN ROAD MP 1.23
TC-08
14 15
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 EB LANE CLOSURE - TEMP. SIGNALS (1 OF 2)
STAGING AREA
ACCESSROAD
CONTRACTOR TO INSTALL TEMPORARY 18-INCH WHITE STOP BAR AT THE
LOCATION SHOWN.
TEMPORARY TRAFFIC CONTROL NOTES:
CONTRACTOR TO REFRESH THE YELLOW CENTERLINE, AS REQUIRED, FOR A
MINIMUM OF 500' ON THE APPROACH TO THE STOP BAR.
11/18/2026
AutoCAD SHX Text
50-100 FT
AutoCAD SHX Text 12'
AutoCAD SHX Text
OVERFLOW BRIDGE
AutoCAD SHX Text R4-9
AutoCAD SHX Text
100' BUFFER
AutoCAD SHX Text
100' TAPER
AutoCAD SHX Text W20-4
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text W20-1
AutoCAD SHX Text 350'
AutoCAD SHX Text 50'-100'
AutoCAD SHX Text R10-6
AutoCAD SHX Text W3-3
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Signal 8-9.dwg
AutoCAD SHX Text
11/18/2026 5:13 PM
AutoCAD SHX Text 11/18/2026
STAY
IN
LANE
PV
ROAD
WORK
AHEAD
HERE ON
STOP
RED
P C M S
P C M S
ONE LANE
ROAD
AHEAD
ROAD
WORK
AHEAD
HERE ON
STOP
RED
DESIGNED BY :
DRAWN BY :
CHECKED BY :
DATE :
NO. DATE BY APP.REVISION
Utilities Underground
Location Center
REFERENCE SHEET NO.
SHEET NO. OF TOTAL
M.D.
M.D.
J.H.
PH CONSULTING
Balanced Transportation Solutions
40 80
SCALE IN FEET
0NOTES:
1. SEE SHEET TC-01 FOR TRAFFIC CONTROL NOTES, CHARTS & LEGEND.
2. TRAFFIC CONE SPACING ON BRIDGE SHALL BE 20FT.
57 WEST MAIN ST.
CHEHALIS WA 98532
PHONE # (360) 740-1123
M A T C H L I N E
J J
S E E
S H E E T
T C
M A T C H L I N E
K K
S E E
B E L O W
L E F T
M A T C H L I N E
K K
S E E
A B O V E
R I G H T
GALVIN RD
(35 M.P.H.)
GALVIN RD
(35 M.P.H.)
MATCHLINE L-L -SEE RIGHT
GALVIN RD
(35 M.P.H.)
RIVER HEIGHTS RD
(25 M .P.H
STAGING AREA
GALVIN ROAD MP 1.23
TC-09
15 15
CONTRACTOR TO ADJUST PCMS LOCATION IN THE FIELD*
MATCHLINE L-L -SEE LEFT
LEWIS COUNTY
PREVENTATIVE BRIDGE MAINTENANCE
PROJECT NO: CRP 2199 EB LANE CLOSURE - TEMP. SIGNALS (2 OF 2)
STAGING AREA
CONTRACTOR TO INSTALL TEMPORARY 18-INCH WHITE STOP BAR AT THE
LOCATION SHOWN.
TEMPORARY TRAFFIC CONTROL NOTES:
CONTRACTOR TO REFRESH THE YELLOW CENTERLINE, AS REQUIRED, FOR A
MINIMUM OF 500' ON THE APPROACH TO THE STOP BAR.
11/18/2026
AutoCAD SHX Text
RIVER BRIDGE
AutoCAD SHX Text R2-1
AutoCAD SHX Text R4-9
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text 200'
AutoCAD SHX Text 200'
AutoCAD SHX Text W20-1
AutoCAD SHX Text R10-6
AutoCAD SHX Text W3-3
AutoCAD SHX Text
450' BUFFER
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text 350'
AutoCAD SHX Text
12'MIN
AutoCAD SHX Text W20-4
AutoCAD SHX Text W20-1
AutoCAD SHX Text R10-6
AutoCAD SHX Text W3-3
AutoCAD SHX Text
40' TO 180'
AutoCAD SHX Text
450' BUFFER
AutoCAD SHX Text "It's the Law"
AutoCAD SHX Text 1-800-
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text
CALL 48 HOURS
AutoCAD SHX Text 424-5555
AutoCAD SHX Text Galvin Bridges- Signal 8-9.dwg
AutoCAD SHX Text
11/18/2026 5:13 PM
AutoCAD SHX Text 11/18/2026
| GALVIN MP 1.23 COVER SHEET - VICINITY MAP-COVER SHEET |
| COVER SHEET |
| LCPS-2199-COVER SHT-GENERAL NOTES AND ABBREVIATIONS |
| GENERAL NOTES AND ABBREVIATIONS |
| LCPS-2199-SP PLANS-GALVIN MP 1.23 |
| GALVIN MP 1.23 |
| LCPS-2199-BRIDGE PLANS-BRIDGE LAYOUT AND TYPICAL SECTION |
| BRIDGE LAYOUT AND TYPICAL SECTION |
| LCPS-2199-BRIDGE DETAILS-EXPANSION JOINT DETAILS |
| EXPANSION JOINT DETAILS |
| LCPS-2199-BRIDGE DETAILS-CR-BA03 |
| CR-BA03 |