BBA130_bro_en_5214-8331-12_v0101.pdf

PDF 12 MB Posted

Attached to
HIGH POWER AMPLIFIER
Solicitation number
Not on record
Issued by

View the file

Other files

File Type Posted
SOW Empower RF (2).docx DOCX document
SOURCES SOUGHT.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pr od uc t B ro ch ur e

| V er si on

1.

R&S®BBA130

Broadband Amplifier The amplifier you can tune year

BBA130_bro_en_5214-8331-12_v0101.indd 1 20.12.2017 08:18:23

R&S®BBA130-BC4200.R&S®BBA130-BC4200.

R&S®BBA130

Broadband Amplifier At a glance The R&S®BBA130 broadband amplifiers offer a variety of setting options so you can optimally tune the output signal to your specific application. During operation, you can adjust the operating class for transistors between Class A and Class AB as well as choose between maximum output power or higher mismatch tolerance at the output.

The primary area of application for R&S®BBA130 broad-band amplifiers is design and product validation test-ing during RF component development, production and quality assurance.

The R&S®BBA130 broadband amplifiers feature a light-weight, modular design that is optimized for the specific frequency range. The amplifiers are available as a desktop andarackmodel.Thelow-poweramplifiersare4 HU, 19" desktop models that can also be installed in a rack.

Devices with higher power are rack models. The ampli-fiers can be operated via the display and buttons, via a remote control interface (automated operation) or via a web browser.

The modular design allows you to later upgrade the power and frequency range. The comprehensive service concept and global availability of spare parts promote the trust and confidence of customers around the world.

Key facts ❙ Three frequency ranges:

■ 80 MHzto1.0 GHz

■ 0.69 GHzto3.2 GHz

■ 2.5 GHzto6.0 GHz

❙ Outputpowerfrom22 Wto4200 W ❙ Operating class for transistors adjustable between Class AandClassAB

❙ Choice between maximum output power or higher mismatch tolerance

❙ Suitable for amplitude, frequency, phase and pulse modulation

❙ Threeyearwarrantyandflexibleservicelevelagreements

BBA130_bro_en_5214-8331-12_v0101.indd 2 20.12.2017 08:18:32

Model overview

Power classes

¸BBA130 (band BC)

¸BBA130 (band D)

¸BBA130 (band E)

100/180/240/350/750/1500/1800/2100/2700/4200 W

45/90/160/300/600/1200 W

22/45/90/150/280 W

4200 W

1200 W

280 W

100 W 45 W 22 W

80 MHz 1 GHz 3.2 GHz2.5 GHz 6 GHz

690 MHz

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 3

R&S®BBA130

Broadband Amplifier Benefits and key features

An amplifier for every application ❙ User-optimizedtuning ❙ Adjustable bias point ❙ Maximumoutputpowerversushigher mismatch tolerance ▷ page 4

Flexible control and operation ❙ Manualoperation ❙ Local and remote operation via web browser and PC ❙ Remote control via Ethernet ❙ Safety thanks two different interlocks ▷ page 7

All in one ❙ Compact, modular design ❙ Compactandflexible:twin-bandanddual-band amplifiersinfourHUs

❙ Extensive switching options for inputs, outputs and sample ports ▷ page 8

Developed with experience and competence ❙ Outstandingexpertiseinamplifierdevelopment founded ondecadesofexperience

❙ State-of-the-art RF design ❙ Series production in one of Europe's most advanced plants ▷ page 10

BBA130_bro_en_5214-8331-12_v0101.indd 3 20.12.2017 08:18:32

Amplification of a 2 ms pulse on the R&S®BBA130

Class A The power increases by 0.2 dB to 0.3 dB during the pulse because the power transistor's junction temperature drops when RF is applied, thereby increasing the amplification.

Class AB The power level changes less than 0.05 dB during the pulse because the power transistor's junction temperature remains fairly constant when RF is applied.

User-optimized tuning The R&S®BBA130 broadband amplifier is ideal for a variety of applications, including development and production validation tests and power sensor calibration. Each application requires different amplifier characteristics. The R&S®BBA130 provides two powerful tools for optimizing its output signal. You can adjust the operating class betweenClass AandClass ABandalsochoosebetween maximum output power or higher mismatch tolerance.

This allows you to optimize the output signal and respond flexibly to a wide range of requirements. You can change both of these parameters while the amplifier is in operation.

An amplifier for every application

BBA130_bro_en_5214-8331-12_v0101.indd 4 20.12.2017 08:18:38

Maximum output power vs. mismatch tolerance on the R&S®BBA130D300

1 2 3 4 5 6 7 8 9 10

Load VSWR

Fo rw ar d po w er in

W

Settings selected for maximum output power

Settings selected for high mismatch tolerance

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 5

Adjustable bias point YoucansetthetransistorbiastoClass A,ClassABorany-where in between in order to change the characteristics oftheoutputsignal.AbiaspointinClass Aprovidesex-cellent linearity with good harmonic performance. A bias pointinClass ABpermitsaccuratereproductionofpulsed signals as well as improved efficiency.

TogenerateacleanCWsignalforadevicetest,operate the R&S®BBA130 in Class A. To accurately amplify pulsed signals,selectabiaspointinClass AB.

Maximum output power versus higher mismatch tolerance Amplifiers are used for a number of different applications.

The R&S®BBA130 allows you to choose between high maximum output power when there is a good impedance match(maximumVSWR approx.2:1)orhighermismatch tolerance with a subsequent reduction in power (starting ataboutVSWR6:1).

Impedance matching at the amplifier output is typically goodduringdesignandproductvalidationtests.Good matchingisensuredwithDUTsdevelopedfora50 Ωsys-tem or when a circulator is inserted between the ampli-fierandtheDUT.Theamplifierpowermarginisthenfully used.MismatchcanonlybetheresultofadefectiveDUT or circulator. The amplifier can therefore reduce its power because it only has to protect itself.

ForEMCapplicationsinvolvingpoorlymatchedantennas orforDUTmeasurementswithaninputimpedancethat deviatessignificantlyfrom50 Ω,theamplifiermustcon-tinue to produce the desired output power for as long as possible and therefore cannot reduce its power to protect itself (unless there is a very large mismatch).

BBA130_bro_en_5214-8331-12_v0101.indd 5 20.12.2017 08:18:42

Amplifier characteristics for various control parameter settings and typical applications

High mismatch tolerance ❙ Poor matching acceptable at amplifier output

High power ❙ Signals with high crest faktor ❙ Good matching needed at amplifier output

Class AB ❙ Faithful reproduction of a pulsed signal ❙ Good efficiency

Class A ❙ High linearity ❙ High spectral integrity

Design and product validation tests ❙ Pulse tests ❙ Slam tests ❙ Tolerance tests ❙ Burn-in

Design and product validation tests ❙ Intermodulation tests, e.g. PIM tests ❙ Multitone tests ❙ Peak-to-average ratio tests

Various tests ❙ Maximum output power depends on amplitude and phase of mismatch

EMC tests ❙ Poor antenna/current probe matching; reflections from DUT and/or EMC chamber Scientific applications ❙ Linear broadband amplifier

Example applications and the appropriate amplifier parameter settings Application R&S®BBA130 settings

Pulse and slam testing These tests require high output power. The R&S®BBA130 protects itself even in the case of catastrophicDUTfailureswithsuddenhighVSWRlevels.

Class AB and high power

Signals with high spectral integrity Here,linearity,peakpowercapabilityandefficiencyneedtobeoptimizedtogether.Typicalsignals include multitone signals or complex modulation schemes with high peak-to-average ratios.

Class A/AB (find optimal slide control setting) and high power

EMC susceptibility testing The amplifier must deliver high power into broadband antennas or coupling networks with high inputVSWRlevelswhilesimultaneouslyensuringlowharmoniccontent.

Class A and maximum mismatch tolerance

Silent and ecological operation Whenonlyafractionoftheoutputpowerisrequired,thepowerefficiencyoftheR&S®BBA130can be maximized by reducing the quiescent currents. This saves energy cost, reduces the acoustic noiseandincreasesamplifierMTBF.

Class AB

BBA130_bro_en_5214-8331-12_v0101.indd 6 20.12.2017 08:18:44

Operating class settings between A and AB and power mode adjustments for high power versus highmismatchtolerance.Below:webGUI.Right:mobileGUI.

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 7

Flexible control and operation

Remote control via Ethernet The standard Ethernet interface makes it possible to automate test sequences using remote control SCPI com-mands. To make integration especially easy, the IP network address can be set manually or assigned automatically via

DHCP.

Safety thanks two different interlocks Two different interlocks are available. You can choose the one that best suits your application. The automatic device interlock is supplemented by a second, interactive inter-lock. The automatic device interlock restarts the amplifier without user interaction as soon as the interlock circuit is closed again. The interactive interlock requires user confir-mation before RF power can be output again.

Manual operation The R&S®BBA130 is operated via the display and the but-tons on the front panel. This is ideal for use in labs and makes it easy to change settings. A clever menu structure provides straightforward access to all essential informa-tion and possible settings; during operation, the RF output power,reflectedpowerandVSWRaredisplayed.

Local and remote operation via web browser and PC ThewebGUIintegratedintotheR&S®BBA130iscalledup via LAN and web browser. The R&S®BBA130 can be con-veniently operated via its graphical user interface using a laptop near the amplifier or a control workstation PC. A standard web browser is all that is needed.

BBA130_bro_en_5214-8331-12_v0101.indd 7 20.12.2017 08:18:50

The R&S®BBA130-BC1500D1200 amplifier system in a19"rackwith35HUsincludes:

❙ Poweramplifier,frequencybandBC,1500W

❙ Poweramplifier,frequencybandD,1200W

❙ Input switch

❙ Output switch

❙ Sample port switch

Compact, modular design Though compact, the R&S®BBA130 broadband amplifier offers functions that normally involve a significantly higher investment in technology. Due to its lightweight design with a special aluminum-copper heat sink, the instrument weighs only half as much as conventional amplifiers in the samepowerclass.AnRFoutputpowerofupto750 W below1 GHzandupto300 Wabove1 GHzinjustfour height units means excellent power density.

The design is optimized for maximum flexibility in a small footprint. The compact, modular design of the amplifier stages and other components allows the setup of highly integrated systems based on 19" rack units. The frequency and power of these rack units can be flexibly configured.

Compact and flexible: twin-band and dual-band amplifiers in four HUs Twofrequencybandscanbeintegratedintoa4 HU desktop model, either as a twin-band amplifier or a dual-band amplifier.

Twin-band amplifiers consist of two amplifiers, both with the same frequency band, that operate in parallel. These types of amplifiers are ideal for two-tone measurements and for applications that require the same test setup for multipletestsinasmallspace.Multipletwin-bandunitsfit in a single rack.

Dual-band amplifiers contain two amplifiers with different frequency bands, and only one of these amplifiers is active at any given time. The optional switches for this option are integrated into the housing. The dual-band amplifiers coverthefollowingfrequencyranges:80 MHzto3.2 GHz and690 MHzto6 GHz.

All in one

BBA130_bro_en_5214-8331-12_v0101.indd 8 20.12.2017 08:18:57

Combined amplifier system with switching options

DUT

¸SMB100A

Forward

RF input switch

Frequency bands Directional couplers RF output switch

Reflected

Sample ports

Sample port switch

80 MHz to 1 GHz

0.69 GHz to 3.2 GHz

2.5 GHz to 6 GHz

ReflectedForward

ReflectedForward

ReflectedForward

Sample port switch

1 6

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 9

Extensive switching options for inputs, outputs and sample ports Single-band and dual-band amplifiers can be combined to build a single system with multiple frequency bands.

Numerous switching options allow you to mix and match the individual amplifiers to obtain the best configuration for your specific application.

Every scenario is covered by flexibly combining the following components.

The input switch sets the RF input signal to one of the frequency bands so that a central input can be used with-out having to disconnect and reconnect the signal source.

Optional sample ports are available to measure the forward and reflected power at the amplifier's output.

Sample port switches make the signals from the various frequency bands available at two central outputs.

RF output switches allow flexible connection of the frequency bands to different sinks, e.g. clamps or antennas. Different RF output switches can be configured in an application-specific manner.

All switches in the system are controlled via the built-in system controller. The desired RF path can be selected with a single remote control command or a press of a button. An RF path is the signal path from the input to the output of the amplifier system.

BBA130_bro_en_5214-8331-12_v0101.indd 9 20.12.2017 08:18:59

Knowledge transfer

All of the Rohde & Schwarz radio and TV transmitter manufacturing know-how has gone into the development of the broadband amplifiers.

1963:

VHF radio transmitter with 2 × 5 kW

2010:

¸BBA100

broadband amplifier

2014:

¸BBL200

broadband amplifier

2016:

¸BBA130

broadband amplifier

2013:

¸BBA150

broadband amplifier

Outstanding expertise in amplifier development founded on decades of experience Rohde & Schwarz has accumulated many years of expe-rience in developing power amplifiers, starting in 1949 with the development of radio and TV transmitters.

Their reliability is well-known and a major reason for the company's global market leadership in digital terres-trial transmitter technology. The R&S®BBA130 fulfills the Rohde & Schwarz promise to offer reliable amplifiers that maximize user effectiveness. Low downtime is an impor-tant economic factor.

State-of-the-art RF design The use of state-of-the-art design and simulation programs during development, the use of power semiconductors from internationally leading manufacturers and the decades of experience of Rohde & Schwarz engineers in developing amplifiers result in the most advanced ampli-fier design currently available. Semiconductor dies directly bonded onto printed boards make it possible to achieve highoutputpowerinthefrequencyrangefrom2.5 GHzto 6 GHz,effectivelypreventingtheparasiticeffectscaused by housed transistors.

Series production in one of Europe's most advanced plants The R&S®BBA130 broadband amplifiers are series-produced in one of Europe's most advanced plants.

The multiple award-winning1) Rohde & Schwarz plant in Teisnach,Germany,offerssuperiormanufacturingdepth.

From precision mechanical engineering and metalworking to printed board production and final assembly, all manu-facturing steps are united under one roof. Automated final test rigs ensure that only products that comply with speci-fications leave the plant.

1) Awards received by the Rohde & Schwarz Teisnach plant include:

■ 2010,2014FactoryoftheYear,Germany

■ 2013 Best Factory, award winner of European industrial excellence competition

■ 2014 Bavarian Quality Award

■ 2016GlobalExcellenceinOperations(GEO)overallawardwinner,Germany

Developed with experience and competence

BBA130_bro_en_5214-8331-12_v0101.indd 10 20.12.2017 08:19:02

Front view

Rear view

System on/standby

Operating buttonsDisplay

RF input 1)Sample ports 1) RF output 1)

Status LEDs

1) Optional or configuration-dependent.

Sample ports 1) RF input 1)

RF output 1)

Power supply

On/off switch

Interlock

System bus

Ethernet

Control interface

1) Optional or configuration-dependent.

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 11

Functional elements Desktop model

BBA130_bro_en_5214-8331-12_v0101.indd 11 20.12.2017 08:19:21

Specifications in brief Specifications in brief RF specifications

Frequency range continuous ❙ 80 MHzto1.0 GHz ❙ 0.69 GHzto3.2 GHz ❙ 2.5 GHzto6.0 GHz

Nominal output power 80 MHzto1.0 GHz 100 Wto4200 W

0.69 GHzto3.2 GHz 45 Wto1200 W

2.5 GHzto6.0 GHz 22 Wto280 W

Nominal output load 50Ω

Gainflatness ±3.8 dB (or better; see data sheet)

Gainadjustmentrange > 15 dB

Bias adjustable Class A through Class AB, continuous

Mismatchtolerance adjustable VSWR2:1to6:1,continuous

Modulationcapability AM,FM,φM,PM

Nominal input impedance 50Ω

MaximumRFinputlevel max. +15 dBm

Input level for nominal output power –3.4 dBm

Nominal output impedance 50Ω

Outputmismatchtolerance,VSWR 100 %, without damage

RF and sample connectors

RF input port N female

RF output port N female, 7/16 DIN female or 1 8/" EIA female

RF sample ports forward output power, optional N female reflected output power, optional N female

Detected sample ports forward output power, optional N female reflected output power, optional N female

Graphical user interface

Local graphical display 200 × 48 pixel, monochrome

WebGUI via Ethernet RJ-45,10/100Mbit/s,autonegotiation,half/full duplex

Remote control

Ethernet RJ-45,10/100Mbit/s,autonegotiation,half/full duplex

General data

Operating voltage range R&S®BBA130-BC100, R&S®BBA130-BC180, R&S®BBA130-D45-D160, R&S®BBA130-E22-E150

100 V to 240 V AC ± 10 %, single phase, 50Hzto60Hz±6%

R&S®BBA130-BC240,

R&S®BBA130-BC350

110 V to 240 V AC ± 10 %, single phase, 50Hzto60Hz±6%

R&S®BBA130-BC750,

R&S®BBA130-D300,

R&S®BBA130-D600,

R&S®BBA130-E280

200 V to 240 V AC ± 10 %, single phase, 50Hzto60Hz±6%

R&S®BBA130-BC1500-BC4200,

R&S®BBA130-D1200

380 V to 415 V AC ± 10 %, three phase, with N, 50Hzto60Hz±6%

Air cooling forced air, built-in fans, air entry at front, air exit at rear

Dimensions

Desktop model W×H×D,incl.fans,handlesandfeet 430 mm × 196 mm × 580 mm (16.93 in × 7.72 in × 22.83 in) for rackmounting 19"1/1,4HU

Rackmodels(W×H×D) R&S®BBA130-BC1500/-D600 19"×12HU×800mm

R&S®BBA130-D1200 19"×20HU×800mm

R&S®BBA130-BC1800/-BC2100/-BC2700 19"×20HU×1000mm

R&S®BBA130-BC4200 19"×35HU×1000mm

BBA130_bro_en_5214-8331-12_v0101.indd 12 20.12.2017 08:19:21

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 13

Specifications in brief Environmental conditions

Temperature range operating temperature 0 °C to +40 °C storage temperature –20 °C to +70 °C

Damp heat max. +40 °C at 95 % rel. humidity, without condensation

Altitude operating altitude up to 2000 m storage altitude up to 4600 m

Protection

LoadVSWR infinite

Interlocks 1 automatic interlock, 1 interactive interlock

Input protection against bias voltage optional DCblocklevel≤50VDC

Transient voltage compatibility category II, in line with IEC 60364-4-443

Short-circuit breaking capacity all-pole 20 A circuit breaker

Thermal overload shutdown in case of thermal overload

Allspecifiedparametersarevalidforanambienttemperatureof+25°C,inputimpedanceof50Ωand outputimpedanceof50Ω.

For data sheet, see PD 5214.8331.22 and www.rohde-schwarz.com

BBA130_bro_en_5214-8331-12_v0101.indd 13 20.12.2017 08:19:21

Ordering information Designation Type Configuration No.

R&S®BBA130 single-band power amplifiers

Frequency band: 80 MHz to 1.0 GHz

100 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC100

180 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC180

240 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC240

350 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC350

750 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC750

1500 W,air-cooled,12HUrackmodel R&S®BBA130 BBA130-BC1500

1800 W,air-cooled,20HUrackmodel R&S®BBA130 BBA130-BC1800

2100 W,air-cooled,20HUrackmodel R&S®BBA130 BBA130-BC2100

2700 W,air-cooled,20HUrackmodel R&S®BBA130 BBA130-BC2700

4200 W,air-cooled,35HUrackmodel R&S®BBA130 BBA130-BC4200

Frequency band: 0.69 GHz to 3.2 GHz

45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D45

90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D90

160 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D160

300 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D300

600 W,air-cooled,12HUrackmodel R&S®BBA130 BBA130-D600

1200 W,air-cooled,20HUrackmodel R&S®BBA130 BBA130-D1200

Frequency band: 2.5 GHz to 6.0 GHz

22 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E22

45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E45

90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E90

150 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E150

280 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E280

Accessories supplied: power cord, user manual on CD.

R&S®BBA130 twin-band power amplifiers 1)

Frequency bands: 2 × 80 MHz to 1 GHz

100 W/100 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC100BC100

180 W/180 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC180BC180

240 W/240 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC240BC240

350 W/350 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC350BC350

Frequency bands: 2 × 0.69 GHz to 3.2 GHz

45 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D45D45

90 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D90D90

160 W/160 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-D160D160

Frequency bands: 2 × 2.5 GHz to 6.0 GHz

22 W/22 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E22E22

45 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E45E45

90 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E90E90

150 W/150 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-E150E150

R&S®BBA130 dual-band power amplifiers 1)

Frequency bands: 80 MHz to 1.0 GHz and 0.69 GHz to 3.2 GHz

180 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC180D45

180 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC180D90

180 W/160 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC180D160

240 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC240D45

240 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC240D90

240 W/160 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC240D160

BBA130_bro_en_5214-8331-12_v0101.indd 14 20.12.2017 08:19:21

Rohde & Schwarz R&S®BBA130 Broadband Amplifier 15

Service options FrequencyRange/OutputPowerUpgrade R&S®BBA-UPGR on request

Service Level Agreement BASIC 1 year, incl. factory repairs, technical support during normal business hours, soft-ware updates, access to Rohde & Schwarz Support Desk

R&S®SB1AMP 5354.6560.02

Service Level Agreement BASIC 2 years, incl. factory repairs, technical support during normal business hours, soft-ware updates, access to Rohde & Schwarz Support Desk

R&S®SB2AMP 5354.6560.03

Service Level Agreement BASIC 3 years, incl. factory repairs, technical support during normal business hours, soft-ware updates, access to Rohde & Schwarz Support Desk

R&S®SB3AMP 5354.6560.04

Your local Rohde & Schwarz expert will help you determine the optimum solution for your requirements.

To find your nearest Rohde & Schwarz representative, visit www.sales.rohde-schwarz.com

Designation Type Configuration No.

350 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC350D45

350 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC350D90

350 W/160 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA130-BC350D160

Frequency bands: 0.69 GHz to 3.2 GHz and 2.5 GHz to 6.0 GHz

45 W/22 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D45E22

45 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D45E45

90 W/22 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D90E22

90 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D90E45

90 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D90E90

160 W/45 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D160E45

160 W/90 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D160E90

160 W/150 W,air-cooled,4HUdesktopmodel R&S®BBA130 BBA150-D160E150

Accessories supplied: power cord, user manual on CD.

Options

GPIBRemoteControl,externalconverter R&S®BBA-B101 5355.8250.02

GPIBRemoteControl,forracksupto30HU R&S®BBA-B101 5355.8250.03

GPIBRemoteControl,forrackshigherthan30HU R&S®BBA-B101 5355.8250.04

RF Input Switch (1:2 or 2:1, N) R&S®BBA-B110 5355.8866.02 2)

RF Input Switch (1:6, N) R&S®BBA-B116 5355.8950.02

RF Output Switch (2:1 or 1:2, N) R&S®BBA-B120 5355.8795.02 2)

RF Output Switch (2:2, 7/16) R&S®BBA-B121 5355.8895.02 2)

RF Output Switch (2:2, 7/8" EIA) R&S®BBA-B122 5355.8989.02

RF Output Switch (2:2, 1 5/8" EIA) R&S®BBA-B123 5355.8943.02

RF Output Switch (6:1, N) R&S®BBA-B126 5355.8995.02

FastAmplifierMute R&S®BBA-B130 5355.8114.02

DC Block Input Protection (N) R&S®BBA-B132 5353.9236.03

RF Forward/RF Reflected Sample Ports (N front) R&S®BBA-B140 5355.8837.02

RF Forward/RF Reflected Sample Ports (N rear) R&S®BBA-B140 5355.8837.03

Detected Forward/Detected Reflected Sample Ports (N front) R&S®BBA-B141 5355.8850.02

Detected Forward/Detected Reflected Sample Ports (N rear) R&S®BBA-B141 5355.8850.03

Sample Port Switch (dual-port, N front) R&S®BBA-B142 5355.8872.02

Sample Port Switch (dual-port, N rear) R&S®BBA-B142 5355.8872.03

Transparent I/O R&S®BBA-B160 5355.8889.02

1) Amplifier systems with two or more frequency bands are available in many combinations. The table shows only a selection of the multiband power amplifiers.

2) The last two digits of the order number depend on the system configuration.

BBA130_bro_en_5214-8331-12_v0101.indd 15 20.12.2017 08:19:21

R&S®isaregisteredtrademarkofRohde&SchwarzGmbH&Co.KG

Trade names are trademarks of the owners

PD5214.8331.12|Version01.01|December2017(fi)

R&S®BBA130BroadbandAmplifier

Data without tolerance limits is not binding | Subject to change

©2017Rohde&SchwarzGmbH&Co.KG|81671Munich,Germany

Service that adds value ❙ Worldwide ❙ Local and personalized ❙ Customized and flexible ❙ Uncompromising quality ❙ Long-term dependability

.8

1.

1.

P

D P e n

Rohde & Schwarz The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and mea-surement, broadcast and media, secure communications, cybersecurity, monitoring and network testing. Founded more than 80 years ago, the independent company which is headquartered in Munich, Germany, has an extensive sales and service network with locations in more than 70 countries.

Sustainable product design ❙ Environmental compatibility and eco-footprint ❙ Energy efficiency and low emissions ❙ Longevity and optimized total cost of ownership

Certified Environmental Management

ISO 14001

Certified Quality Management

ISO 9001

Regional contact ❙ Europe, Africa, Middle East | +49 89 4129 12345 customersupport@rohde-schwarz.com

❙ North America | 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com

❙ Latin America | +1 410 910 79 88 customersupport.la@rohde-schwarz.com

❙ Asia Pacific | +65 65 13 04 88 customersupport.asia@rohde-schwarz.com

❙ China | +86 800 810 82 28 | +86 400 650 58 96 customersupport.china@rohde-schwarz.com

Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com

Rohde & Schwarz training www.training.rohde-schwarz.com

5214833112

BBA130_bro_en_5214-8331-12_v0101.indd 16 20.12.2017 08:19:22

File details come from the government source that posted it. Updated .