B50330 Clayton Co O_M Demolition VOL_2 Attach.pdf

PDF 16 MB Posted

Attached to
IFB B50330 Clayton County Multipurpose Operations & Maintenance Facility ¿ Demolition
Solicitation number
PE-97100-NONST-2024-000000053
Issued by
Clayton County, Georgia

About this file

The document appears to be Volume 2 of the attachments for Invitation for Bids (IFB) B50330 issued by the Metropolitan Atlanta Rapid Transit Authority (MARTA) for the Clayton County Multipurpose Operations & Maintenance Facility - Demolition project. The IFB seeks bids from firms to demolish two existing buildings, on-site utilities, pavement, and other site features on the project site located in Georgia.

The IFB provides detailed specifications and requirements for the demolition work, including site work, utility disconnections, and disposal of demolished materials. The bid submission deadline is stated, along with information about a mandatory pre-bid conference for interested bidders. The contract will be awarded to the responsive and responsible bidder submitting the lowest total bid price, and the awarded contractor will be required to complete the work within a specified timeframe.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Volume 2 of 2 - Environmental Reports

CLAYTON COUNTY

MULTIPURPOSE OPERATIONS

& MAINTENANCE FACILITY -

DEMOLITION

Project Number / Contract Number

32242 & 70002 / B50330

CAPITAL PROGRAMS DELIVERY &

DESIGN, ENGINEERING, AND INFRASTRUCTURE

DocuSign Envelope ID: 06217E30-5F4A-4429-8CAB-31400736C058

This page is intentionally left blank for double-sided printing.

B50330 – VOLUME 2 TOC - 1

VOLUME 2 - ENVIRONMENTAL REPORTS

TABLE OF CONTENTS

Report 1: Hazardous Materials Assessment Report at 5163 Old Dixie Hwy, Forest Park, Clayton

County, GA 30297; prepared by Corporate Environmental Risk Management, LLC (CERM), dated May 24, 2023

Report 2: Hazardous Materials Assessment Report at 5265 Old Dixie Hwy, Forest Park, Clayton County, GA 30297; prepared by Corporate Environmental Risk Management, LLC (CERM), dated May 24, 2023

Report 3: Limited Phase II Environmental Site Assessment at 5265 Old Dixie Highway, Forest Park, Clayton County, Georgia 30297; prepared by by Corporate Environmental Risk Management, LLC (CERM), dated June 21, 2023

Report 4: Limited Phase II Environmental Site Assessment at Proposed Clayton County Operations & Maintenance Facility, 5163 Old Dixie Highway, Forest Park, Clayton County, Georgia;

prepared by AECOM, dated June 2, 2021

END OF VOLUME 2 TABLE OF CONTENTS

REPORT 1

Hazardous Materials Assessment Report

5163 Old Dixie Hwy

Forest Park, Clayton County, GA 30297

Prepared for:

STV, Inc.

225 Park Ave South

New York, New York 10003

Prepared by:

Corporate Environmental Risk Management, LLC

1990 Lakeside Parkway

Tucker, GA 30084

2023-1511A-001B

May 24, 2023

Table of Contents

SAMPLING METHODOLOGY

LABORATORY RESULTS & FINDINGS

RECOMMENDATIONS

LIMITATIONS

SCHEMATICS SAMPLE/TESTING LOCATIONS UNIVERSAL WASTE NOTES

PHOTO LOG

LABORATORY ANALYTICAL RESULTS

ASBESTOS INSPECTOR CERTIFICATION

LEAD INSPECTOR CERTIFICATION

CORPORATE HEADQUARTERS

1990 Lakeside Parkway, Suite 300 ● Tucker, GA 30084

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 1

May 24, 2023

Mr. Jeffrey Messinger, P.E. (jeffrey.messinger@stvinc.com)

Project Manager

STV, Inc.

225 Park Ave South

New York, New York, 10003

RE: Hazardous Materials Assessment Report

5163 Old Dixie Hwy

Forest Park, Clayton County GA 30297

CERM Project No. 2023-1511A-001A

Dear Mr. Messinger, Corporate Environmental Risk Management, LLC (CERM) was retained by STV, Inc. to conduct a Pre-

Demolition Hazardous Materials (HazMat) Assessment at 5163 Old Dixie Hwy, Forest Park, Clayton

County, GA 30297. At the time of the assessment, there were two tenant spaces in the building. The

SCP Distributors (Pool Supply Company) section of the building was an unoccupied office space and a vacant warehouse. The Tsunami Volleyball area was currently in use and occupied by the tenant.

Mr. Lorenzo Gates, Darryl Edler, and Andre Cumberbatch of CERM, conducted the on-site sampling and evaluations of the Hazardous Materials Assessment on April 3, 2023 and April 12-13, 2023. The

HazMat Assessment of this facility was coordinated with the HazMat Assessment of the south adjacent

5265 Old Dixie Hwy, an occupied secured-access facility requiring an escort. The assessment reports are provided under separate cover. No as-built drawings were available for use by CERM in performance of this assessment.

SCOPE OF SERVICES

The Scope of Services for the above referenced property included a Pre-Demolition Hazardous

Materials Assessment. The HazMat assessment included the following tasks:

1) Asbestos-Containing Materials (ACM) Sampling;

2) Lead-Based Paint (LBP) Testing; and

3) Universal Waste Inventory for PCB-containing equipment (i.e., light ballasts, electrical transformers, hydraulic equipment), mercury-containing equipment, fluorescent light bulbs, and other chemical storage containers.

All work was performed in accordance with applicable state and federal guidelines and industry standards.

//cerm.com

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 2

SAMPLING METHODOLOGY

SUSPECT ASBESTOS-CONTAINING MATERIALS

All accessible areas of the building were observed for suspect asbestos-containing materials (ACM).

Small pieces of each observed suspect ACM were collected using a metal chisel, and/or other means, including a hammer where necessary. Each sample was placed in an individual plastic container and given a unique sample identification number. The sample number, material location, and material description were recorded on a field survey log. In accordance with Environmental Protection Agency

(EPA) guidelines, multiple samples were collected of each homogeneous (same color, texture, and/or application date) area (material). As a general rule, when one of multiple samples of a homogeneous material yields a result >1%, the material is considered an ACM. The samples were transported to

Analytical Environmental Services, Inc. (AES) for analysis of total asbestos content (% by volume).

SUSPECT LEAD-BASED PAINT

All accessible areas of the building were observed for suspect lead-based paints (LBP). Suspect painted surfaces were tested for lead content by hand-held instrument or by paint film collection for laboratory analysis. CERM utilized a handheld Niton XL2 GOLDD X-Ray Fluorescence (XRF) Analyzer by

Thermo Scientific to collect direct readings of painted surfaces throughout the subject building. If a measurement of a painted surface by XRF yields a reading at or above 1.0 milligrams per square centimeter (mg/cm ) that paint film is considered lead-based paint.

Small pieces of each observed suspect LBP were collected using a utility knife, metal chisel, and/or other means. Each sample was placed in an individual plastic container and given a unique sample identification number. The sample number, material location, and material description were recorded on a field survey log. Representative samples of each suspect LBP were collected for analysis. The samples were transported to Analytical Environmental Services, Inc. (AES) for analysis of lead content

(% by weight).

UNIVERSAL WASTE INVENTORY

The inspection of accessible areas of the building for other hazardous materials such as stored chemicals, PCB light ballasts and mercury-containing equipment consisted of identifying and characterizing known or suspected hazardous materials.

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 3

LABORATORY RESULTS & FINDINGS

The suspect ACM samples collected consisted of drywall/joint compound material, ceiling tile, flooring materials, thermal system (pipe) insulation (TSI), and roofing materials. The samples were transported to AES under chain of custody for analysis. The samples were analyzed by Polarized Light

Microscopy (PLM) coupled with dispersion staining techniques in accordance with the EPA “Method for the Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116, July 1993”.

EPA/NESHAP regulations define an asbestos-containing material (ACM) as a material containing greater than one percent (>1%) asbestos in a bulk sample. CERM collected fifty-eight (58) samples of suspect asbestos-containing materials. The results are summarized in Table 1: Suspect Asbestos-

Containing Materials (ACM) Results. The laboratory analytical report and completed chain of custody are attached.

Table 1: Suspect Asbestos-Containing Materials (ACM) Results

Sample ID Suspect Material Location Quantity (SF) Results (%)

SCP Distributors

(Pool Supply

Company)

5163PC-01 Drywall & Joint

Compound

Back (East)

Warehouse Wall

N/A ND

5163PC-02 Drywall Compound

Only

Back (East)

Warehouse Wall

N/A ND

5163PC-03 Drywall & Joint

Compound

Back (East)

Warehouse Wall

N/A ND

5163PC-04 Drywall Compound

Only

Back (East)

Warehouse Wall

N/A ND

5163PC-05 Drywall & Joint

Compound

Back Warehouse

Restroom

N/A ND

5163PC-06 2' x 4' Ceiling Tile Back Warehouse

Restroom

N/A ND

5163PC-07 12" x 12" Floor Tile Back Warehouse

Restroom

N/A ND

5163PC-08 Vinyl Covebase Back Warehouse

Restroom

N/A ND

5163PC-09 Drywall & Joint

Compound

North (Entry) Wall N/A ND

5163PC-10 Floor Mastic Northeast Corner N/A ND

5163PC-11 Pipe Insulation

Covering

North Central

Warehouse

N/A ND

5163PC-12 Dot Material on

Column

South Central

Warehouse

N/A ND

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 4

Sample ID Suspect Material Location Quantity (SF) Results (%)

5163PC-13 12" x 12" Floor Tile West Warehouse

Restroom

N/A ND

5163PC-14 Drywall & Joint

Compound

West Warehouse

Restroom

N/A ND

5163PC-15 2' x 4' Ceiling Tile West Warehouse

Restroom

N/A ND

5163PC-16 Vinyl Covebase West Warehouse

Restroom

N/A ND

5163PC-17 Drywall Compound Warehouse at

Electric Room

N/A ND

5163PC-18 2' x 4' Ceiling Tile Office Reception N/A ND

5163PC-19 2' x 4' Ceiling Tile Office Women's

Restroom

N/A ND

5163PC-20 Drywall Joint

Compound

Reception Office N/A ND

5163PC-21 12" x 12" Floor Tile Forklift Warehouse

Entrance

N/A ND

5163PC-22 Drywall Joint

Compound

Reception Window N/A ND

5163PC-23 12" x 12" Floor Tile Hallway N/A ND

5163PC-24 Drywall Compound Reception at

Thermostat

N/A ND

5163 Old Dixie

Hwy Roof

5163RF-01 Roof Membrane &

Insulation

Roof East N/A ND

5163RF-02 Roof Membrane &

Insulation

Roof Southeast N/A ND

5163RF-03 Roof Membrane &

Insulation

Roof Central N/A ND

5163RF-04 Roof Membrane &

Insulation

Roof West N/A ND

5163PW-05 Parapet Wall

Covering

Roof Northeast N/A ND

5163PF-06 Flashing at Parapet

Wall

Roof Northeast N/A ND

5163CF-07 Flashing at A/C

Compressor

Roof South Central N/A ND

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 5

Sample ID Suspect Material Location Quantity (SF) Results (%)

Tsunami Volleyball

5163TV-01 12" x 12" Floor Tile Tsunami Volleyballl, Concession Area

N/A ND

5163TV-02 Vinyl Covebase &

Mastic

Tsunami Volleyballl, Concession Area

N/A ND

5163TV-03 2' x 4' Ceilling Tile Tsunami Volleyballl, Concession Area

N/A ND

5163TV-04 Drywall Joint

Material

Tsunami Volleyballl, Concession Area

N/A ND

5163TV-05 12" x 12" Floor Tile Tsunami Volleyballl, Laundry Area

N/A ND

5163TV-06 Vinyl Covebase &

Mastic

Tsunami Volleyballl, Laundry Area

N/A ND

5163TV-07 2' x 4' Ceilling Tile Tsunami Volleyballl, Laundry Area

N/A ND

5163TV-08 Drywall Joint

Material

Tsunami Volleyballl, Laundry Area

N/A ND

5163TV-09 Sink Undercoating Tsunami Volleyballl, Laundry Area

N/A ND

5163TV-10 2' x 4' Ceilling Tile Tsunami Volleyballl, Retail Store

N/A ND

5163TV-11 Drywall Joint

Material

Tsunami Volleyballl, Retail Store

N/A ND

5163TV-12 Drywall Joint

Material

Tsunami Volleyballl, Storage

N/A ND

5163TV-13 12" x 12" Floor Tile Tsunami Volleyballl, Women's Restroom

N/A ND

5163TV-14 Vinyl Covebase Tsunami Volleyballl, Women's Restroom

N/A ND

5163TV-15 Drywall Joint

Material

Tsunami Volleyballl, Women's Restroom

N/A ND

5163TV-16 12" x 12" Floor Tile Tsunami Volleyballl, Electrical Room

N/A ND

5163TV-17 Drywall Joint

Material

Tsunami Volleyballl, Electrical Room

N/A ND

5163TV-18 Drywall & Joint

Compound

Tsunami Volleyballl, Wall Support at

Column

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 6

Sample ID Suspect Material Location Quantity (SF) Results (%)

5163TV-19 Pipe Insulation Tsunami Volleyballl, Court East Wall

N/A ND

5163TV-20 12" x 12" Floor Tile Tsunami Volleyballl, Annex Restroom

N/A ND

5163TV-21 12" x 12" Floor Tile Tsunami Volleyballl, Annex Restroom

N/A ND

5163TV-22 Drywall Joint

Material

Tsunami Volleyballl, Exterior Restroom

Wall

N/A ND

5163TV-23 Drywall Joint

Material

Tsunami Volleyballl, Annex Restroom

N/A ND

5163TV-24 12" x 12" Floor Tile Tsunami Volleyballl, Annex Foyer

N/A ND

5163TV-25 2' x 2' Ceilling Tile Tsunami Volleyballl, Annex Foyer

N/A ND

5163TV-26 Drywall Joint

Material

Tsunami Volleyballl, Annex Court Wall

N/A ND

5163TV-27 Vinyl Covebase Tsunami Volleyballl, Annex Foyer

N/A ND

N/A - Not Applicable ND - None Detected

Laboratory analysis of bulk samples collected at the 5163 Old Dixie Hwy warehouse building did not detect the presence of asbestos in any of the samples collected. However, mirrors on the walls of the Women's and Men's Restrooms in the Tsunami space are assumed to be adhered to the wall by asbestos-containing glue dots. Investigating for the presence of glue dots was not possible without removing the mirrors and incurring risk of damaging them in this occupied tenant space. The laboratory analytical report and completed Chains of Custody are attached. (See the attached

Laboratory Analytical Results Report for a detailed listing of all the samples that were examined at

5163 Old Dixie Hwy)

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 7

Lead-based paint is defined as paint with lead levels that are greater than or equal to 0.5% by weight.

Four (4) suspect lead-based paint samples were collected at the 5163 Old Dixie Hwy warehouse building. The samples were submitted under chain of custody for analysis of total lead content

(percent by weight). The laboratory analytical results report and completed chain of custody are attached.

Table 2: Lead-Based Paint (LBP) Results

Sample ID Suspect Material Location Quantity (SF) Results (%)

5163LP-01 Exterior Ballards SCP Distributors

(Pool Supply

Company)

N/A 0.0181

5163LP-02 Outside Steps SCP Distributors

(Pool Supply

Company)

N/A 0.0800

5163LP-03 Inside of Dock Door SCP Distributors

(Pool Supply

Company)

N/A BRL

5163LP-04 South Exterior Wall SCP Distributors

(Pool Supply

Company)

N/A BRL

NA – Not Applicable BRL – Not Detected at the Reporting Limit

A lead concentration greater than or equal to 0.5% by weight was not detected in any of the suspected lead-based paint samples collected at 5163 Old Dixie Hwy.

Renovation or other activities conducted by employees (of any entity) that impact the materials or otherwise expose employees to lead are governed by OSHA (29 CFR 1926.62). EPA also has testing requirements that apply to the waste stream of building materials that contain lead as characterization for disposal (i.e., landfilling/incineration). EPA regulations and HUD guidelines will apply if the facility is sold or renovated for reuse, particularly as a “child-occupied facility”.

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 8

Universal Waste Inventory at the 5163 Old Dixie Hwy warehouse building for fluorescent light bulbs, suspect PCB-containing equipment (i.e., light ballasts, electrical transformers, hydraulic equipment), and suspect mercury-containing thermostats yielded the following results:

Table 3: Universal Waste Inventory

Location Fluorescent Light Bulbs Suspect PCB Light

Ballasts

Suspect Mercury-

Containing Thermostats

SCP Distributors (Pool

Supply Company)

480 Bulbs No PCBs 1

Tsunami Volleyball 409 Bulbs No PCBs N/A

The universal waste inventory of SCP Distributors at 5163 Old Dixie Hwy revealed approximately four hundred and eighty (480) fluorescent light bulbs (mercury-containing), no PCB ballast were detected from the light fixtures checked, and there was one (1) suspect mercury-containing thermostats found in the foyer office area.

The universal waste inventory of Tsunami Volleyball at 5163 Old Dixie Hwy revealed approximately four hundred and nine (409) fluorescent light bulbs (mercury-containing), no PCB ballast were detected from the light fixtures checked, and there were no suspect mercury-containing thermostats found in the Tsunami Volleyball area.

Any mercury-containing fluorescent light bulbs, mercury-containing thermostat components, and PCB light ballasts should be properly disposed in accordance with Georgia Solid Waste Rules.

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 9

RECOMMENDATIONS

The presence of (assumed) asbestos-containing glue dots in the Tsunami space Women's and Men's

Restrooms should be confirmed prior to demolition of the building. If determined to be asbestos-containing material, the mirrors and adhesive dots should be removed and disposed of by a Georgia-licensed asbestos abatement contractor. CERM recommends that any portion of the building material waste-stream that includes lead-based paint should be characterized by toxicity characteristic leaching procedure (TCLP) laboratory analysis in order to determine whether it must be disposed as hazardous.

CERM recommends that fluorescent light bulbs and mercury-containing thermostats, where applicable, be submitted to a licensed recycling facility. These items should be contained in sealed packages for transport. EPA recommends that these items be handled by trained professionals. CERM recommends that all suspect PCB-containing light ballasts be removed, contained in sealed drums and shipped to a licensed incineration facility for disposal. For occupied facilities, federal law requires that any suspect

PCB-containing light ballasts that are found to be leaking be immediately removed and disposed of.

Department of Transportation (DOT) requirements may also apply.

Phone: 678-999-0173 ● Fax: 678-999-0186 cerm.com 10

LIMITATIONS

The findings of the hazardous materials assessment by CERM were based on observations of existing conditions at the site during the investigation. This assessment was conducted on behalf of, and for the exclusive use of STV, Inc. for 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297. The intent of this report is to aid the building owner, architect, construction manager, general contractors, and potential demolition and abatement contractors in locating identified hazardous materials.

Topics not explicitly discussed within this document should not be assumed to have been investigated.

The data reported and findings, observations, conclusions, and recommendations expressed in the report are limited by the Scope of Services. The Scope of Services was defined by the Client, to include the time and budget, and the availability of access to the subject property.

Actual site conditions and quantities should be field verified; this report is not intended to serve as a bidding document or as a project specification document. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of the users and use or reuse of this document or the findings, conclusions, or recommendations is at the risk of said user.

Although every attempt has been made to identify suspect asbestos-containing materials in the areas identified, the destructive inspection technique used is inherently limited in the sense that only full demolition procedures will reveal all building materials of a structure. Additionally, the passage of time may result in changes in the environmental condition of a site. This report does not guarantee future operations or conditions that could affect the recommendations made. The results, findings, conclusions, and recommendations expressed in this report are based only on conditions that were observed during CERM’s inspection of the site.

Because of the limitations stated above, the findings, observations, conclusions, and recommendations expressed by CERM. in this report are limited to the information obtained and the investigation undertaken should not be considered an opinion concerning the compliance of any past or current owner or operator of the subject property with any federal, state, or local law or regulation. No warranty or guarantee, whether expressed or implied, is made with respect to the data reported or findings, observations, conclusions, and recommendations expressed in this report. Further, such data, findings, observations, conclusions, and recommendations are based solely upon site conditions in existence at the time of the investigation.

CERM appreciates the opportunity to provide this service to STV, Inc.. Should you have any questions or concerns regarding this project, please contact CERM at (678) 999-0173.

Best regards, Corporate Environmental Risk Management, LLC

Lorenzo Gates

Senior Enviromental Scientist

Date: 5/24/2023

Darryl Edler

Project Manager

Date: 5/24/2023

SCHEMATICS

SAMPLE/TESTING LOCATIONS

UNIVERSAL WASTE NOTES

PHOTO LOG

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 1 Comments: SCP Distributors Foyer

Photo 2 Comments: SCP Distributors Foyer

Photo 3 Comments: SCP Distributors Warehouse Area

Photo 4 Comments: SCP Distributors Warehouse Area

Photo 5 Comments: SCP Distributors Offices

Photo 6 Comments: SCP Distributors Offices

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 9 Comments: SCP Distributors North Wall

Photo 10 Comments: SCP Distributors East Wall

Photo 11 Comments: SCP Distributors Warehouse Facing West

Photo 12 Comments: Fluorescent Light Fixtures

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 7 Comments: SCP Distributors Restrooms

Photo 8 Comments: Piping

Photo 9 Comments: SCP Distributors North Wall

Photo 10 Comments: SCP Distributors East Wall

Photo 11 Comments: SCP Distributors Warehouse Facing West

Photo 12 Comments: Fluorescent Light Fixtures

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 15 Comments: SCP Distributors Bay Loading Overhead Doors

Photo 16 Comments: Lift Cutout

Photo 17 Comments: Loading Dock Exit Door (2)

Photo 18 Comments: Loading Dock Exit Door

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 13 Comments: Dot Material on Column

Photo 14 Comments: Sprinkler System Mechanical Area

Photo 15 Comments: SCP Distributors Bay Loading Overhead Doors

Photo 16 Comments: Lift Cutout

Photo 17 Comments: Loading Dock Exit Door (2)

Photo 18 Comments: Loading Dock Exit Door

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 21 Comments: No PCB's Ballast Sticker

Photo 22 Comments: Light Fixture

Photo 23 Comments: 20230403_151601

Photo 24 Comments: Mercury Containing Thermostat

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 19 Comments: Loading Dock

Photo 20 Comments: Restroom

Photo 21 Comments: No PCB's Ballast Sticker

Photo 22 Comments: Light Fixture

Photo 23 Comments: 20230403_151601

Photo 24 Comments: Mercury Containing Thermostat

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 27 Comments: Tsunami Volleyball Concessions

Photo 28 Comments: Tsunami Volleyball Laundry Area

Photo 29 Comments: Tsunami Volleyball Office

Photo 30 Comments: 20230413_115111

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 25 Comments: Tsunami Volleyball Concessions

Photo 26 Comments: Tsunami Volleyball Concessions

Photo 27 Comments: Tsunami Volleyball Concessions

Photo 28 Comments: Tsunami Volleyball Laundry Area

Photo 29 Comments: Tsunami Volleyball Office

Photo 30 Comments: 20230413_115111

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 33 Comments: Tsunami Volleyball Entrance

Photo 34 Comments: Court Map

Photo 35 Comments: Tsunami Volleyball Court

Photo 36 Comments: Tsunami Volleyball Court

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 31 Comments: Tsunami Volleyball Office

Photo 32 Comments: Tsunami Volleyball Office

Photo 33 Comments: Tsunami Volleyball Entrance

Photo 34 Comments: Court Map

Photo 35 Comments: Tsunami Volleyball Court

Photo 36 Comments: Tsunami Volleyball Court

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 39 Comments: Fluorescent Lights

Photo 40 Comments: Tsunami Volleyball Court

Photo 41 Comments: Tsunami Volleyball Court

Photo 42 Comments: Pipe Insulation

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 37 Comments: Tsunami Volleyball Court

Photo 38 Comments: Ceiling Pipes

Photo 39 Comments: Fluorescent Lights

Photo 40 Comments: Tsunami Volleyball Court

Photo 41 Comments: Tsunami Volleyball Court

Photo 42 Comments: Pipe Insulation

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 45 Comments: Tsunami Volleyball Court

Photo 46 Comments: Restrooms

Photo 47 Comments: Mirror & Sinks

Photo 48 Comments: Restroom

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 43 Comments: Tsunami Volleyball Court

Photo 44 Comments: Tsunami Volleyball Court Bleachers

Photo 45 Comments: Tsunami Volleyball Court

Photo 46 Comments: Restrooms

Photo 47 Comments: Mirror & Sinks

Photo 48 Comments: Restroom

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 51 Comments: Equipment Area

Photo 52 Comments: Equipment Area

Photo 53 Comments: Equipment Area

Photo 54 Comments: Equipment Area

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 49 Comments: Restroom Vent Motor

Photo 50 Comments: Storage Closet

Photo 51 Comments: Equipment Area

Photo 52 Comments: Equipment Area

Photo 53 Comments: Equipment Area

Photo 54 Comments: Equipment Area

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 57 Comments: Mechanical Area

Photo 58 Comments: Exit Sign

Photo 59 Comments: 5163 Old Dixie Hwy Roof Field

Photo 60 Comments: 5163 Old Dixie Hwy Roof Field

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 55 Comments: Ceiling Tile

Photo 56 Comments: Mechanical Area

Photo 57 Comments: Mechanical Area

Photo 58 Comments: Exit Sign

Photo 59 Comments: 5163 Old Dixie Hwy Roof Field

Photo 60 Comments: 5163 Old Dixie Hwy Roof Field

Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 63 Comments: 5163 Old Dixie Hwy Roof Field

Photo 64 Comments: 5163 Old Dixie Hwy Roof Flashing

Photo 65 Comments: 5163 Old Dixie Hwy Roof Field

Project Name: 5163 Old Dixie Hwy Address: 5163 Old Dixie Hwy, Forest Park, Clayton County, GA 30297 Project No: 2023-1511A-001A

Photo Log

Photo 61 Comments: 5163 Old Dixie Hwy Roof A/C

Photo 62 Comments: 5163 Old Dixie Hwy Roof A/C Compressor

Photo 63 Comments: 5163 Old Dixie Hwy Roof Field

Photo 64 Comments: 5163 Old Dixie Hwy Roof Flashing

Photo 65 Comments: 5163 Old Dixie Hwy Roof Field

LABORATORY ANALYTICAL RESULTS

ANALYTICAL ENVIRONMENTAL SERVICES, INC.

10-Apr-23

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

Joint compoundNDNDNDNDNDNDSEE COC2304149-

001A

5163PC-01

Layer:

NDNDNDNDNDNDSEE COC2304149-

001A

5163PC-01

Layer:

NDNDNDNDNDNDSEE COC2304149-

001A

5163PC-01

Layer:

NDNDNDNDNDNDSEE COC2304149-

002A

5163PC-02

Layer:

NDNDNDNDNDNDSEE COC2304149-

002A

5163PC-02

Layer:

Joint compoundNDNDNDNDNDNDSEE COC2304149-

003A

5163PC-03

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304149-

003A

5163PC-03

Layer:

NDNDNDNDNDNDSEE COC2304149-

003A

5163PC-03

Layer:

NDNDNDNDNDNDSEE COC2304149-

004A

5163PC-04

Layer:

NDNDNDNDNDNDSEE COC2304149-

004A

5163PC-04

Layer:

Joint compoundNDNDNDNDNDNDSEE COC2304149-

005A

5163PC-05

Layer:

NDNDNDNDNDNDSEE COC2304149-

005A

5163PC-05

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304149-

005A

5163PC-05

Layer:

Paint included as binderNDNDNDNDNDNDSEE COC2304149-

006A

5163PC-06

Layer:

Floor tileNDNDNDNDNDNDSEE COC2304149-

007A

5163PC-07

Layer:

GlueNDNDNDNDNDNDSEE COC2304149-

007A

5163PC-07

Layer:

NDNDNDNDNDNDSEE COC2304149-

008A

5163PC-08

Layer:

NDNDNDNDNDNDSEE COC2304149-

008A

5163PC-08

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304149-

008A

5163PC-08

Layer:

Joint compoundNDNDNDNDNDNDSEE COC2304149-

009A

5163PC-09

Layer:

NDNDNDNDNDNDSEE COC2304149-

009A

5163PC-09

Layer:

NDNDNDNDNDNDSEE COC2304149-

010A

5163PC-10

Layer:

NDNDNDNDNDNDSEE COC2304149-

011A

5163PC-11

Layer:

NDNDNDNDNDNDSEE COC2304149-

012A

5163PC-12

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

Floor tileNDNDNDNDNDNDSEE COC2304149-

013A

5163PC-13

Layer:

GlueNDNDNDNDNDNDSEE COC2304149-

013A

5163PC-13

Layer:

Joint compound. Paint included as binder

NDNDNDNDNDNDSEE COC2304149-

014A

5163PC-14

Layer:

NDNDNDNDNDNDSEE COC2304149-

014A

5163PC-14

Layer:

NDNDNDNDNDNDSEE COC2304149-

014A

5163PC-14

Layer:

Paint included as binderNDNDNDNDNDNDSEE COC2304149-

015A

5163PC-15

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304149-

016A

5163PC-16

Layer:

NDNDNDNDNDNDSEE COC2304149-

016A

5163PC-16

Layer:

NDNDNDNDNDNDSEE COC2304149-

016A

5163PC-16

Layer:

Joint compoundNDNDNDNDNDNDSEE COC2304149-

017A

5163PC-17

Layer:

Paint included as binderNDNDNDNDNDNDSEE COC2304149-

018A

5163PC-18

Layer:

Paint included as binderNDNDNDNDNDNDSEE COC2304149-

019A

5163PC-19

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

Joint compound. Paint included as binder

NDNDNDNDNDNDSEE COC2304149-

020A

5163PC-20

Layer:

Floor tileNDNDNDNDNDNDSEE COC2304149-

021A

5163PC-21

Layer:

GlueNDNDNDNDNDNDSEE COC2304149-

021A

5163PC-21

Layer:

Joint compound. Paint included as binder

NDNDNDNDNDNDSEE COC2304149-

022A

5163PC-22

Layer:

Floor tileNDNDNDNDNDNDSEE COC2304149-

023A

5163PC-23

Layer:

GlueNDNDNDNDNDNDSEE COC2304149-

023A

5163PC-23

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304149

5163 OLD DIXIE HWY HAZMAT 0422-00347

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

Paint included as binderNDNDNDNDNDNDSEE COC2304149-

024A

5163PC-24

Layer:

NDNDNDNDNDNDSEE COC2304149-

024A

5163PC-24

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab

Code 102082-0. All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA

600/M4-82-020), 1982 as found in 40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building

Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaSvetlana Arkhipov

End of Report

19-Apr-23

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304D71

5163 OLD DIXIE HWY

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304D71

-001A

5163RF-01

Layer:

NDNDNDNDNDNDSEE COC2304D71

-001A

5163RF-01

Layer:

NDNDNDNDNDNDSEE COC2304D71

-001A

5163RF-01

Layer:

NDNDNDNDNDNDSEE COC2304D71

-002A

5163RF-02

Layer:

NDNDNDNDNDNDSEE COC2304D71

-002A

5163RF-02

Layer:

NDNDNDNDNDNDSEE COC2304D71

-002A

5163RF-02

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab Code 102082-0.

All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA 600/M4-82-020), 1982 as found in

40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaPenka Topuzova Page 2 of 6

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304D71

5163 OLD DIXIE HWY

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304D71

-003A

5163RF-03

Layer:

NDNDNDNDNDNDSEE COC2304D71

-003A

5163RF-03

Layer:

NDNDNDNDNDNDSEE COC2304D71

-003A

5163RF-03

Layer:

NDNDNDNDNDNDSEE COC2304D71

-004A

5163RF-04

Layer:

NDNDNDNDNDNDSEE COC2304D71

-004A

5163RF-04

Layer:

NDNDNDNDNDNDSEE COC2304D71

-004A

5163RF-04

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab Code 102082-0.

All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA 600/M4-82-020), 1982 as found in

40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaPenka Topuzova Page 3 of 6

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304D71

5163 OLD DIXIE HWY

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304D71

-005A

5163PW-05

Layer:

NDNDNDNDNDNDSEE COC2304D71

-005A

5163PW-05

Layer:

NDNDNDNDNDNDSEE COC2304D71

-006A

5163PF-06

Layer:

NDNDNDNDNDNDSEE COC2304D71

-007A

5163CF-07

Layer:

NDNDNDNDNDNDSEE COC2304D71

-007A

5163CF-07

Layer:

NDNDNDNDNDNDSEE COC2304D71

-007A

5163CF-07

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab Code 102082-0.

All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA 600/M4-82-020), 1982 as found in

40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaPenka Topuzova Page 4 of 6

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304D71

5163 OLD DIXIE HWY

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304D71

-007A

5163CF-07

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab Code 102082-0.

All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA 600/M4-82-020), 1982 as found in

40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaPenka Topuzova Page 5 of 6

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304F44

5163 OLD DIXIE HWY

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

Floor tileNDNDNDNDNDNDSEE COC2304F44-

001A

5163TV-01

Layer:

GlueNDNDNDNDNDNDSEE COC2304F44-

001A

5163TV-01

Layer:

VinylNDNDNDNDNDNDSEE COC2304F44-

002A

5163TV-02

Layer:

GlueNDNDNDNDNDNDSEE COC2304F44-

002A

5163TV-02

Layer:

Paint included as binderNDNDNDNDNDNDSEE COC2304F44-

003A

5163TV-03

Layer:

Joint compound. Paint included as binder

NDNDNDNDNDNDSEE COC2304F44-

004A

5163TV-04

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite, AN=anthophylite

ND = None Detected

For comments on the samples, see the individual analysis sheets.

AES,Inc. is accredited by NIST’s National Voluntary Laboratory Accreditation Program (NVLAP) for Polarized Light Microscopy (PLM) analysis, Lab Code 102082-0.

All analyses performed in accordance with EPA “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA 600/M4-82-020), 1982 as found in

40 CFR, Part 763, Appendix E to Subpart E and “Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116), 1993.

These test results apply only to those samples actually tested, as submitted by the client. All percentages are reported by visually estimated volume.

PLM is not consistently reliable in detecting small concentrations of asbestos in floor tiles and similar nonfriable materials, quantitative TEM is currently the only method that can be used to determine conclusive asbestos content.

This report must not be reproduced except in full without written approval of Analytical Environmental Services , Inc.

Microanalyst: QC Analyst:

Yelena KhaninaElena Ivanova Page 3 of 13

Bulk Sample Summary Report

AES Job Number:

Project Number:Project Name:

Client Name:

LocationClient ID AES ID Asbestos Mineral Percentage Comments

2304F44

5163 OLD DIXIE HWY

Corporate Environmental Risk Management, LLC.

AMCH CR AN TR AC

3080 Presidential Drive

Atlanta,GA 30340

Tel :(770) 457-8177

Fax:(770) 457-8188 Report Date:

NDNDNDNDNDNDSEE COC2304F44-

004A

5163TV-04

Layer:

NDNDNDNDNDNDSEE COC2304F44-

004A

5163TV-04

Layer:

Floor tileNDNDNDNDNDNDSEE COC2304F44-

005A

5163TV-05

Layer:

GlueNDNDNDNDNDNDSEE COC2304F44-

005A

5163TV-05

Layer:

NDNDNDNDNDNDSEE COC2304F44-

006A

5163TV-06

Layer:

NDNDNDNDNDNDSEE COC2304F44-

006A

5163TV-06

Layer:

Note: CH=chrysotile, AM=amosite, CR=crocidolite, AC=actinolite, TR=tremolite,…