This Statement of Objectives (SOO) outlines requirements for fabrication and installation of classroom network consoles for the US Air Force Test Pilot School Building 2750, Room 104. The consoles must accommodate 36 users in a classroom row configuration within a 31ft x 42ft room, with 6 users per row and 6 total rows facing projectors along the 42ft wall.
The consoles must meet specific technology requirements including rack space for NIPR/JWICS/SGN computers (Mirage B3000S and HP Z2 G9 Mini), Belkin Secure KVM switch, and surge protectors. Each workstation requires a 24" LG monitor, mouse, and keyboard mounted on a VESA mount. Security requirements include TAA compliance, US manufacturing per SCIF/SAPF standards, and NIPR/SIPR/TEMPEST/JWICS compliance with cable separation. The work surface must be 24-30 inches deep with 7" minimum rack depth. Delivery and installation are required by April 30, 2025, with liftgate service required as no forklift is available at the delivery dock.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Q A from vendors for TPS Classroom Network Consoles March 4 2025.docx | DOCX document | |
| B2750 Floor Plan Requirement Reference.pdf | ||
| Service Contract Act WD 2015-5603.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF OBJECTIVES
US Air Force Test Pilot School (TPS) B2750 Classroom Network Consoles
Current as of 20 February 2025
1. SCOPE:
The government requires the fabrication and installation of classroom consoles that allow for IT integration into the back of the desks. This will allow for SCIF security and IT requirements to be met.
2. REQUIREMENT:
• Technology Requirements o Rack in the back of desks must be able to be customizable and fit the following equipment per user:
1 – Mirage B3000S (NIPR) Small Form Factor PC 2 – HP Z2 G9 Mini (or other Mini Form Factor PC) - (JWICS/SGN) 1 – Belkin Secure KVM F1DN204KVM-UN-4 2 – Surge Protectors (1 to connect Unclassified equipment / 1 for
Classified Equipment) o Top Surface of Console must fit the following equipment per user
1 – 24” Monitor - LG 24BL450YB001 Mouse Keyboard No data or power grommets on surface No task lights o Power at each station under the work surface
• Security Requirements o Must be TAA compliant and manufactured in the United States per SCIF/SAPF requirements.
o NIPR/SIPR Requirements o TEMPEST Requirements o JWICS Requirements o Must have cable/network separation
• Console Requirements o Simple, straight edge design o Consoles/Design need to fit 36 users in a classroom ‘row’ configuration
Room is 31ftx42ft 3ft wide per user. 6 users per row. 6 rows in total.
Desks will be facing projectors and whiteboards along the 42ft wall o Work surface must be 24in-30in deep o Pole or other VESA mount option for the monitors to maximize limited surface space.
o Rack space in the back needs a minimum of at least 7” depth to accommodate our SFF NIPR PC.
o Rack space in the back has slat wall to mount the PC’s and KVM.
3. SPECIFICATIONS:
• The vendor shall fabricate and install all furniture into the appropriate classroom space on the second floor, room 104 of building 2750.
• See attached concept diagram
4. DELIVERY:
Liftgate required. The contractor shall deliver/install all furniture that meet the above requirements no later than 30 April 2025. Delivery address will be provided upon award.
Items, when delivered, will be accepted and inspected by the government officials responsible for receiving the products and performing any required inspections.
There is a delivery dock but no forklift at the site location.