B2080_Siemens_Sources Sought_Attachment 2.docx

DOCX document 17 KB Posted

Attached to
B2080 RENOVATION OF GALLEY, EMERGENCY DEPARTMENT AND PHARMACY, NAVAL AIR STATION, JACKSONVILLE, FLORIDA ~ SIEMENS FIRE ALARM SYSTEM
Solicitation number
N6945024R0057-4
Issued by

About this file

This document is a Sources Sought announcement for a federal contract opportunity to identify potential sources for a fire alarm system and control unit compatible with the existing Siemens fire alarm system at the Naval Hospital in Jacksonville, Florida. The procurement involves the design, engineering, and construction services for the renovation of various departments within the hospital's Building 2080.

The key requirements include providing a list of commercially available fire alarm system, control units, and associated equipment that are compatible with the existing Siemens FireFinder XLSV system. Respondents are also requested to provide information on their experience with integrating fire alarm systems into the existing NAS Jacksonville Naval Hospital fire alarm infrastructure. The government is conducting market research to determine product availability and adequacy of potential sources prior to any future solicitation. Responses are due by November 25, 2024, and no contract will be awarded from this announcement.

View the file

Other files

File Type Posted
B2080 Sources Sought_Attachment 1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOURCES SOUGHT INFORMATION

Sources Sought No.: N6945024R0057 B2080 Renovation of Galley, Emergency Department and Pharmacy at the NAS Jacksonville, FL Attachment 2

1. Fire Alarm System, Fire Alarm Control Unit (FACU) and related equipment (2 pages Maximum):

Provide a list of commercially available Fire Alarm System, Control Units and associated equipment manufactured and installed by your organization, that are compatible with Siemens Fire Alarm System, Siemens XLSV FireFinder FACU.

The procurement for B2080 encompasses design, engineering and construction services, along with the integration of personal property and transition services necessary for the renovation of the Emergency, Morgue, Security, Galley, Kitchen, Nutritional Counseling, Inpatient Pharmacy, ENT Balance Lab, Sleep Disorder Services, Biomedical Engineering, Outpatient Behavioral Health departments, all located within existing Hospital Building 2080 at NAS Jacksonville, FL.

The project requires new equipment to be integrated into the existing fire alarm system. The fire alarm system is a comprehensive fire protection system designed to detect fires, alert occupants, and activate building safety measures. It includes both manual and automatic detection capabilities and is intended to notify able-bodied occupants to evacuate and alert staff to implement the facility's fire safety plan for those who may need assistance.

The system interfaces with other building systems to perform fire safety functions such as closing fire-rated doors, recalling elevators, and shutting down ventilation systems. Additionally, it automatically alerts local emergency services for a timely response.

The existing system is a Siemens FireFinder XLSV networked system that communicates with a receiving station using a Kingfisher industrial radio alarm control system. It's important to note that while this is a fire alarm system, it's not a mass notification system. Upgrading to a combined system is not necessary based on the current facility needs.

The project involves modifying the Siemens XLSV FireFinder FACU to install new equipment and components and program the system to control building systems and transmit alarm signals. These modifications must be compatible with the existing system to ensure integrated fire alarm and suppression capabilities.

To maintain consistency and interoperability, the expansion of the fire alarm system should utilize compatible Siemens products. It is crucial to ensure compatibility so that the existing system's functionality and certifications are not compromised, avoiding the need for extensive reprogramming, cybersecurity recertification, and user retraining.

Include the following information for nurse call system:

1. Model Number, Catalog Number, Code Number, or equivalent model designation

1. Product Description

1. Manufacturer's technical data sheets.

2. Experience (3 pages Maximum):

Identify one (1) to three (3) projects where Fire Alarm System, Fire Alarm Control Unit (FACU) had fully integrated with existing NAS Jacksonville, FL Naval Hospital fire alarm system. For each project, provide the customer point of contact including name, phone number, and email, and a narrative description of the product/services provided by your organization. Also provide project title, project location (city/state), procurement contract number, and contract value, if available.