B2 SCHEMATIC DRAWINGS and RECORD DWGs.pdf

PDF 6 MB Posted

Attached to
Natick Building 2 Facade Federal contract opportunity
Solicitation number
W911QY-25-R-A020
Issued by
Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground

About this file

These are schematic and record drawings for Building 2 at the U.S. Army Soldier Systems Center in Natick, Massachusetts, dated 1952 and 1993. The drawings include detailed floor plans, roof plans, and elevations for all four sides of the building (north, south, east, and west), showing both existing and proposed demolition and reconstruction configurations. The drawings provide comprehensive architectural details including building dimensions, grid lines, structural elements, window and door placements, and specific notations about demolition and reconstruction activities for the building envelope.

The drawings are part of a pre-solicitation notice for a construction contract (W911QY-25-R-A020) to replace the building's exterior envelope, with an estimated project value between $1,000,000 and $5,000,000. The project is a 100% small business set-aside under NAICS code 236220 for Commercial and Institutional Building Construction. The anticipated contract period is 270 days after notice to proceed, with solicitation expected to be issued in August 2025. The project involves extensive facade renovation at the Natick Soldier Systems Center, with detailed technical specifications for structural modifications, window replacements, and overall building envelope improvements.

View the file

Other files for this federal contract opportunity

Other files attached to Natick Building 2 Facade, newest first.
File Type Posted
Repair Exteriors Building 2 Design-Build Solicitation July 2020.pdf PDF
B2 ASBESTOS PCB and PAINT REPORTS.pdf PDF
Natick ISWMP January 2025.pdf PDF
B2 Repair Building Envelope (Facade) DPW SOW.pdf PDF
USAG-Natick-Fillable-Visitor-Request-Form-Dec-2024.pdf PDF
B2 MOA for PROTECTION of HISTORICAL PROP.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix A Schematic drawings & Record drawings Schematic drawings including Plans and Elevations

Record drawings including Plans and Elevations dated 1952 and 1993

N N

PROJECT

LOCATION

PROJECT

LOCATION

LAWRENCE

LEXINGTON

DEDHAM

NATICK LABS

21 8

09 9

CONCORD

BEDFORD

LOWELL

NASHUA

NH

MA

S

IX

T H

A V

E N

U E

D

BROCKTON

WEYMOUTH

HINGHAM

L P

A R

K

IN

G

PATIO

AREA

LANDIN

G

HELIC

OPTER

D E

P A

R T

U R

E

A P

P R

O A

C H

Z O

N E

PARKING

M

H

PARKING

E

P A

R K

IN

G

"D" STREET

F

IF

T H

A V

E N

U E

T-24

SHED

"A" STREET

PARKING

"C" STREET

"B" STREET

P A

R K

IN

G

LOGAN INT. AIRPORT

BOSTON

ATLANTIC OCEAN

SALEM

P A

R K

IN

G

PARKING

K

F

IR

S T

A V

E N

U E

PARKING

I

J

B E A C H

O P E N

ROCKPORT

N H

M A

R E

S E

R V

A T

IO

N

B O

U N

D A

R Y

T-75

H

T-27

T-76

T H

IR

D

A V

E N

U E

"C" STREET

F O

U R

T H

A V

E N

U E

F

S

IX

T H

A V

E N

U E

C

PARKING

STATION

PARKING

S E

C O

N D

A V

E N

U E

A

PARKING

B

P A

R K

IN

G

SENTRY

S-6

UPPER ENTRANCE LANE

LO

W

ER

E

N

TR

AN

C E L

AN

E

ENTRANCEM

AIN

SOLDIER SYSTEMS CENTER

T H

IR

D

S T

R E

E T

NO.1

TENT

T -2

T-26

NATICK, MA

U.S. ARMY

L A

K E

C

O C

H I T

U A

T E

L A K E C O C H I T U A T E

VICINITY MAP BASE MAP

TO RT 27

GUARD HOUSE

(BLDG. 39)

KANSAS STREET

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

M

AR

K D

ES

C

R

IP

TI

O

N

New England District

G-001

C O

VE

R

S H

EE

T

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

U.S. ARMY SOLDIER SYSTEMS CENTER

JUNE 2020

NATICK, MASSACHUSETTS

BUILDING 2 ENVELOPE REPLACEMENT

BU

IL

D

IN

G

E N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SHEET INDEX

Number Sheet Name

G-001 COVER SHEET

AD-101 DEMOLITION FLOOR PLAN

AD-111 DEMOLITION ROOF PLAN

AD-201 DEMOLITION ELEVATIONS

AD-202 DEMOLITION ELEVATIONS

A-101 NEW FLOOR PLAN

A-110 NEW ROOF PLAN

A-201 EXTERIOR ELEVATIONS

A-202 EXTERIOR ELEVATIONS

AB-1958 BUILT-UP ROOF AS-BUILT APRIL 1958

AB-1952 CLIMATIC BUILDING ELEVATIONS AS-BUILT, AUG 1952

AB-2002 ELEVATIONS & SECTIONS AS-BUILT, JAN 2002

DN

DN

1 3 5 10 11 14 16

8 2825 41 44 463133

J

DD

AD-202

D1

AD-202

A1

AD-201

D1

AD-201

A1

4 6 21 29 30 34 40 4519 23

V

231' - 4 1/2"

I

11 33 212222 2324

22 22 222222222222 25 42

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR TO VERIFY DEMOLITION WORK IN

RELATION TO NEW WORK LIMITS BEFORE

COMMENCING WORK.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING

AND/OR RELOCATING ALL WALL MOUNTED CONDUIT AS

REQUIRED TO INSTALL EXTERIOR FINISH SYSTEM.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

AD-101

D

EM

O

LI

TI

O

N F

LO

O

R P

LA

N

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

0-

-1

D

R

AW

IN

G

C O

D E:

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/16" = 1'-0"A1 DEMOLITION FLOOR PLAN 08 16 3241216

SCALE: 1/16"=1'-0"

NORTH

EEDP

21 REMOVE EXISTING EIFS SYSTEM TO

STRUCTURAL CMU WALL, TYP.

22 REMOVE EXISTING WINDOW AND FRAME,

TYP.

23 REMOVE EXISTING STOREFRONT ENTRY.

24 REMOVE EXISTING DOOR AND FRAME.

25 REMOVE EXISTING LOADING DOOR AND

FRAME.

26 DEMOLISH EXISTING CONCRETE RAMP AND

RAILING.

27 DEMOLISH EXISTING CONCRETE STAIRS

AND RAILING.

28 ABATEMENT OF ASBESTOS NECESSARY FOR

REMOVAL.

CCDP

1 REMOVE EXISTING PAINT. REMOVE RUST,

TYP.

2 REMOVE EXISTING FENCE AND GATE

3 REMOVE EXISTING METAL DOOR

OVERHANG.

DRP

42 REMOVE EXISTING ROOF ACCESS LADDER.

CLIMATIC CHAMBERS NOTES

EXTERIOR ENCLOSURE NOTES

ROOF NOTES

1 3 5 10 168 44 4631 3326 35 42

J

2 4 6 13 21 29 40 459 18 19 23

F

R

B

E

I

21 21

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

4. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

5. CONTRACTOR TO VERIFY DEMOLITION WORK IN

RELATION TO NEW WORK LIMITS BEFORE

COMMENCING WORK.

6. ALL ROOFTOP UNITS AND FANS ARE TO BE

DISCONNECTED AND REINSTALLED ON NEW ROOF

CURBS.

7. INSPECT ALL ROOF DRAIN PANS AND IF DAMAGED OR

DETERIORATED, INSTALL NEW RETRO FIT ROOF DRAIN

INTO EXISTING DRAIN PAN. REPLACE ALL STRAINERS.

8. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

PHASING OF ROOFTOP EQUIPMENT ONTO NEW CURBS

WITH COR.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

AD-111

D

EM

O

LI

TI

O

N R

O O

F

PL

AN

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/16" = 1'-0"A1 EXISTING ROOF DEMOLITION PLAN

08 16 3241216

SCALE: 1/16"=1'-0"

008 16 3241216

SCALE: 1/16"=1'-0"

NORTH

RRDP

41 REMOVE EXISTING EPDM ROOF IN ITS

ENTIRETY TO CONCRETE DECK.

42 REMOVE EXISTING ROOF ACCESS LADDER.

43 REMOVE EXISTING STEEL HVAC SUPPORT

STRUCTURE.

EEDRP

21 REMOVE EXISTING EIFS SYSTEM TO

STRUCTURAL CMU WALL, TYP.

CCDRP

1 REMOVE EXISTING PAINT. REMOVE RUST,

TYP.

3 REMOVE EXISTING METAL DOOR

OVERHANG.

CLIMATIC CHAMBERS NOTES

FINISH FLOOR

169' - 9"

1 3 5 11 16 20 25 37 44 4631 3315 22 26 35 42

ROOF

184' - 8"

2 4 6 12 17 21 29 40 45I

DORIOT CLIMATIC CHAMBERS

11 33 2122 23 2221 3131

FINISH FLOOR

169' - 9"

TO PARAPET

186' - 2"

A PH U W X Y AA FF HH LL MMKC T

CRAWL SPACE

163' - 9"

ROOF

184' - 8"

G L S BB CC EE GG KK NN PP RR

1224 2721 29

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING

AND/OR RELOCATING ALL WALL MOUNTED CONDUIT AS

REQUIRED TO INSTALL EXTERIOR FINISH SYSTEM.

7. ALL EXISTING LIGHTING TO BE REINSTALLED UNLESS

NOTED OTHERWISE.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

AD-201

D

EM

O

LI

TI

O

N E

LE

VA

TI

O

N S

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/8" = 1'-0"D1 NORTH DEMOLITION ELEVATION

SCALE: 1/8" = 1'-0"A1 EAST DEMOLITION ELEVATION

CCDEN

1 REMOVE EXISTING PAINT. REMOVE RUST, TYP.

2 REMOVE EXISTING FENCE AND GATE

3 REMOVE EXISTING METAL DOOR OVERHANG.

EEDEN

21 REMOVE EXISTING EIFS SYSTEM TO STRUCTURAL

CMU WALL, TYP.

22 REMOVE EXISTING WINDOW AND FRAME, TYP.

23 REMOVE EXISTING STOREFRONT ENTRY.

24 REMOVE EXISTING DOOR AND FRAME.

27 DEMOLISH EXISTING CONCRETE STAIRS AND RAILING.

29 EXISTING FLOOD LIGHT TO BE DISCONNECTED,

REMOVED AND REINSTALLED UPON COMPLETION OF

INSTALLATION OF NEW METAL PANEL SYSTEM.

30 REMOVE EXISTING METAL WALL PANEL AT

INTERSECTION OF WALL AND CLIMATIC CHAMBERS.

31 REMOVE EXISTING EXTERIOR LIGHTING WALL PACKS.

REFER TO ELECTRICAL SCOPE.

CLIMATIC CHAMBERS NOTES

TO PARAPET

186' - 2"

13511141628 25414446 3133 2635

ROOF

184' - 8"

24672134394345 918181924 23 I

4221 252122 22 222222222222 2521 3129 333129

FINISH FLOOR

169' - 9"

TO PARAPET

186' - 2"

AHNWXYAAHHLLMM T

CRAWL SPACE

163' - 9"

ROOF

184' - 8"

GLSBBCCEEGGJJNNPPRR BE

1 2 422427 2129 25

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING

AND/OR RELOCATING ALL WALL MOUNTED CONDUIT AS

REQUIRED TO INSTALL EXTERIOR FINISH SYSTEM.

7. ALL EXISTING LIGHTING TO BE REINSTALLED UNLESS

NOTED OTHERWISE.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

AD-202

D

EM

O

LI

TI

O

N E

LE

VA

TI

O

N S

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/8" = 1'-0"D1 SOUTH DEMOLITION ELEVATION

SCALE: 1/8" = 1'-0"A1 WEST DEMOLITION ELEVATION

CCDES

1 REMOVE EXISTING PAINT. REMOVE RUST, TYP.

2 REMOVE EXISTING FENCE AND GATE

EEDES

21 REMOVE EXISTING EIFS SYSTEM TO STRUCTURAL

CMU WALL, TYP.

22 REMOVE EXISTING WINDOW AND FRAME, TYP.

24 REMOVE EXISTING DOOR AND FRAME.

25 REMOVE EXISTING LOADING DOOR AND FRAME.

27 DEMOLISH EXISTING CONCRETE RAMP AND RAILING

29 EXISTING FLOOD LIGHT TO BE DISCONNECTED,

REMOVED AND REINSTALLED UPON COMPLETION OF

INSTALLTION OF NEW METAL PANEL SYSTEM.

30 REMOVE EXISTING METAL WALL PANEL AT

INTERSECTION OF WALL AND CLIMATIC CHAMBERS.

31 REMOVE EXISTING EXTERIOR LIGHTING WALL PACKS.

REFER TO ELECTRICAL SCOPE.

33 REMOVE EXISTING LOADING DOCK LADDER.

RDE

42 REMOVE EXISTING ROOF ACCESS LADDER.

CLIMATIC CHAMBERS NOTES

DNDNDN

DN

DN

DN

1 3 5 10 11 14 16

8 2825 44 4631 231' - 4 1/2"

J

DD

2 4 6 21 30 34 40 43 4518 19 23

D

M

R

Z

V

KK

B

A-201 A1

A-201 D1

A-202 D1

A-202 A1

I

76 1212222

222222222222 29 25

7 6 24 23

22 22

28 28

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR TO VERIFY DEMOLITION WORK IN

RELATION TO NEW WORK LIMITS BEFORE

COMMENCING WORK.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING

AND/OR RELOCATING ALL WALL MOUNTED CONDUIT AS

REQUIRED TO INSTALL EXTERIOR FINISH SYSTEM.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-101

N

EW

F

LO

O R

P

LA

N

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/16" = 1'-0"A1 NEW FLOOR PLAN

08 16 3241216

SCALE: 1/16"=1'-0"

NORTH

CCP

1 APPLY PROTECTIVE COATING TO EXTERIOR

OF CLIMATIC CHAMBERS.

2 NEW ACCESS CONTROL FENCE

3 CLEAN AND PAINT CRAWL SPACE ACCESS

DOORS AND FRAME.

4 CLEAN CONCRETE FOUNDATION AND

RECAULK JOINT TO METAL CHAMBER.

5 CLEAN COURTYARD AREA OF DEBRIS AND

VEGETATION.

6 CLEAN EXISTING LOADING DOCK LEVELER.

7 REPAIR EXISTING CONCRETE LOADING

DOCK AND STAIR, AS NECESSARY.

EEP

21 PROVIDE NEW EXTERIOR METAL PANEL

WALL SYSTEM

22 NEW LOW-E GLAZING ALUMINUM WINDOWS

TO MATCH EXISTING APPEARANCE.

23 NEW STOREFRONT ENTRY SYSTEM.

24 NEW INSULATED METAL DOOR

25 NEW INSULATED SECTIONAL OVERHEAD

DOOR

26 NEW CONCRETE SERVICE RAMP AND

RAILING.

27 NEW CONCRETE STAIR WITH TRACTION

STRIPS AND RAILING.

28 REPAIR EXISTING STAIR AND TRACTION

STRIPS.

29 NEW STEEL ENCASED CONCRETE BOLLARD,

TYP.

34 CLEAN CRAWL SPACE ACCESS DOORS.

CLIMATIC CHAMBERS NOTES

EXTERIOR ENCLOSURE NOTES

RP Copy 1

42 NEW ACCESS CONTROLLED METAL ROOF

STAIR

1 3 5 10 168 2825 44 4633 42

J

2 4 6 1713 21 30 40 459 19 23

R

B

E

231' - 4 1/2"

SLO

PE

DOW

N

I

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR TO VERIFY DEMOLITION WORK IN

RELATION TO NEW WORK LIMITS BEFORE

COMMENCING WORK.

7. ALL ROOFTOP UNITS AND FANS ARE TO BE

DISCONNECTED AND REINSTALLED ON NEW ROOF

CURBS.

8. INSPECT ALL INTERIOR ROOF DRAIN PANS AND IF

DAMAGED OR DETERIORATED, INSTALL NEW RETRO

FIT ROOF DRAIN INTO EXISTING DRAIN PAN. REPLACE

ALL STRAINERS.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-110

N

EW

R O

O F

PL

AN

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/16" = 1'-0"A1 NEW ROOF PLAN

08 16 3241216

SCALE: 1/16"=1'-0"

NORTH

CCRP

1 APPLY PROTECTIVE COATING TO EXTERIOR

OF CLIMATIC CHAMBERS.

RRP

41 NEW ROOF SYSTEM, TO INCLUDE WALK

PADS, CURBS, AND FLASHING, AS

REQUIRED.

42 NEW ACCESS CONTROLLED METAL ROOF

STAIR

EERP

30 PROVIDE NEW EXTERIOR METAL PANEL

WALL SYSTEM AT INTERSECTION OF

CLIMATIC CHAMBERS AND BUILDING.

CLIMATIC CHAMBERS NOTES

TO PARAPET

186' - 2"

1 3 5 11 16 20 25 37 44 4631 3315 22 26 35 422 4 6 12 17 21 29 40 45

DORIOT CLIMATIC CHAMBERS

I

14762122224 1 7 6 2328 2828 2831318 8

FINISH FLOOR

169' - 9"

TO PARAPET

186' - 2"

A PH U W X Y AA FF HH LL MMKC T

CRAWL SPACE

163' - 9"

ROOF

184' - 8"

G L S BB CC EE GG KK NN PP RR

21 412127 31 2924

50' - 2 3/4"

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING

AND/OR RELOCATING ALL WALL MOUNTED CONDUIT AS

REQUIRED TO INSTALL EXTERIOR FINISH SYSTEM.

7. ALL SIGNAGE TO BE REINSTALLED.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-201

EX

TE

R

IO

R E

LE

VA

TI

O

N S

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/8" = 1'-0"D1 NORTH ELEVATION

SCALE: 1/8" = 1'-0"A1 EAST ELEVATION 04 8 16268

SCALE: 1/8"=1'-0"

CCEN

1 APPLY PROTECTIVE COATING TO EXTERIOR OF CLIMATIC

CHAMBERS.

2 NEW ACCESS CONTROL FENCE

4 CLEAN CONCRETE FOUNDATION AND RECAULK JOINT TO

METAL CHAMBER.

6 CLEAN EXISTING LOADING DOCK LEVELER.

7 REPAIR EXISTING CONCRETE LOADING DOCK, AS NECESSARY.

8 CLEAN EXISTING LOADING DOCK DOOR. PROVIDE NEW

OVERHANG. PROVIDE PROTECTION FROM INFILTRATION OF

WILDLIFE.

EEEN/E

21 PROVIDE NEW EXTERIOR METAL PANEL WALL SYSTEM

22 NEW LOW-E GLAZING ALUMINUM WINDOWS TO MATCH

EXISTING APPEARANCE.

23 NEW STOREFRONT ENTRY SYSTEM.

24 NEW INSULATED METAL DOOR

27 NEW CONCRETE STAIR WITH TRACTION STRIPS AND RAILING.

28 REPAIR EXISTING STAIR AND TRACTION STRIPS.

29 EXISTING FLOOD LIGHT TO BE DISCONNECTED, REMOVED AND

REINSTALLED UPON COMPLETION OF INSTALLATION OF NEW

METAL PANEL SYSTEM.

30 PROVIDE NEW EXTERIOR METAL PANEL WALL SYSTEM AT

INTERSECTION OF CLIMATIC CHAMBERS AND BUILDING.

31 NEW EXTERIOR LIGHTING. SEE ELECTRICAL SCOPE.

34 CLEAN CRAWL SPACE ACCESS DOORS.

CLIMATIC CHAMBERS NOTES

TO PARAPET

186' - 2"

13511141628 25414446 3133 2635

ROOF

184' - 8"

24672134394345 991818

24 23 I

3221 2542 21 21 32253122 22 222222222222 2929 31 3332

FINISH FLOOR

169' - 9"

TO PARAPET

186' - 2"

AHNWXYAAHHLLMM T

CRAWL SPACE

163' - 9"

ROOF

184' - 8"

GLSBBCCEEGGJJNNPPRR BE

32214 1 2 26 25 421 2431 29

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, FINISHES AND

DIMENSIONS PRIOR TO DEMOLITION. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES.

2. CONTRACTOR SHALL TAKE ALL NECESSARY

PRECAUTIONS TO MAINTAIN AND ENSURE THE

INTEGRITY OF THE EXISTING STRUCTURES AT ALL

TIMES.

3. BUILDING WILL BE OCCUPIED AND SHALL REMAIN

FUNCTIONAL DURING CONSTRUCTION. COORDINATE

WORK TO CAUSE MINIMAL DISRUPTIONS TO

OCCUPANTS.

4. ANY EXISTING ITEMS, FINISHES, AND SURFACES

DISTURBED OR DAMAGED BY THE CONTRACTOR

DURING CONSTRUCTION OPERATIONS NOT INDICATED

FOR REMOVAL BOTH INSIDE AND OUTSIDE THE

CONTRACT LIMITS SHALL BE PATCHED / REPAIRED TO

MATCH & BLEND WITH EXISTING ADJACENT SURFACES

WITH APPROVAL FROM THE CONTRACTING OFFICER.

5. DRAWINGS ARE APPROXIMATE AND ARE FOR

REFERENCE ONLY.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING

AND/OR RELOCATING ALL WALL MOUNTED CONDUIT AS

REQUIRED TO INSTALL EXTERIOR FINISH SYSTEM.

7. ALL SIGNAGE TO BE REINSTALLED.

US Army Corps of Engineers ®

SH

EE

T O

F

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-202

EX

TE

R

IO

R E

LE

VA

TI

O

N S

U .S

. A R

M Y

SO

LD

IE

R

S

YS

TE

M

S C

EN

TE

R N

EW

E

N G

LA

N

D D

IS

TR

IC

T

C O

N C

O R

D , M

A

2-

M

LJ

M

LJ

JM

S

KM

J

JU

N

E

RFP

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

BU

IL

D

IN

G

E

N

VE

LO

PE

R

EP

LA

C

EM

EN

T

SCALE: 1/8" = 1'-0"D1 SOUTH ELEVATION

SCALE: 1/8" = 1'-0"A1 WEST ELEVATION

04 8 16268

SCALE: 1/8"=1'-0"

CCEW

1 APPLY PROTECTIVE COATING TO EXTERIOR OF

CLIMATIC CHAMBERS.

2 NEW ACCESS CONTROL FENCE

4 CLEAN CONCRETE FOUNDATION AND RECAULK JOINT

TO METAL CHAMBER.

CLIMATIC CHAMBERS NOTES

EEES/W

21 PROVIDE NEW EXTERIOR METAL PANEL WALL

SYSTEM

22 NEW LOW-E GLAZING ALUMINUM WINDOWS TO

MATCH EXISTING APPEARANCE.

24 NEW INSULATED METAL DOOR

25 NEW INSULATED SECTIONAL OVERHEAD DOOR

26 NEW CONCRETE SERVICE RAMP AND RAILING.

29 EXISTING FLOOD LIGHT TO BE DISCONNECTED,

REMOVED AND REINSTALLED UPON COMPLETION OF

INSTALLATION OF NEW METAL PANEL SYSTEM.

30 PROVIDE NEW EXTERIOR METAL PANEL WALL

SYSTEM AT INTERSECTION OF CLIMATIC CHAMBERS

AND BUILDING.

31 NEW EXTERIOR LIGHTING. SEE ELECTRICAL SCOPE.

32 NEW STEEL ENCASED CONCRETE BOLLARD, TYP.

33 NEW LOADING DOCK LADDER.

EXTERIOR ENCLOSURE NOTES

RP

42 NEW ACCESS CONTROLLED METAL ROOF STAIR

Appendix A1.pdf
Appendix A.pdf
Appendix A
NSSC_B2_Doriot Climactic Chambers_RFP
G-001 - COVER SHEET
Sheets
G-001 - COVER SHEET
AD-101 - DEMOLITION PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-111 - DEMOLITION ROOF PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-201 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-101 - FLOOR PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-110 - ROOF PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-201 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Appendix A
NSSC_B2_Doriot Climactic Chambers_RFP
G-001 - COVER SHEET
Sheets
G-001 - COVER SHEET
AD-101 - DEMOLITION PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-111 - DEMOLITION ROOF PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-201 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-101 - FLOOR PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-110 - ROOF PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-201 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
NSSC_B2_Doriot Climactic Chambers_16Jun2020
G-001 - COVER SHEET
AD-101 - DEMOLITION FLOOR PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-101 - NEW FLOOR PLAN
A-110 - NEW ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
Appendix A1
Appendix A.pdf
NSSC_B2_Doriot Climactic Chambers_RFP
G-001 - COVER SHEET
Sheets
G-001 - COVER SHEET
AD-101 - DEMOLITION PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-111 - DEMOLITION ROOF PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-201 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-101 - FLOOR PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-110 - ROOF PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-201 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Appendix A
NSSC_B2_Doriot Climactic Chambers_RFP
G-001 - COVER SHEET
Sheets
G-001 - COVER SHEET
AD-101 - DEMOLITION PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-111 - DEMOLITION ROOF PLAN
Sheets
AD-101 - DEMOLITION PLAN
AD-111 - DEMOLITION ROOF PLAN
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
G-001 - COVER SHEET
AD-201 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-101 - FLOOR PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-110 - ROOF PLAN
Sheets
A-101 - FLOOR PLAN
A-110 - ROOF PLAN
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
G-001 - COVER SHEET
A-201 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
Sheets
A-201 - EXTERIOR ELEVATIONS
A-202 - EXTERIOR ELEVATIONS
AD-201 - DEMOLITION ELEVATIONS
AD-202 - DEMOLITION ELEVATIONS
Appendix A EP Review JP 30_April_2020
Appendix A
Appendix A
Bldg 2, New Built-Up Roof,April 1958_20141021_0001
Bldg. 2, 4 of 72, Climatic Building Elevations, Aug. 1952_20141016_0001
Bldg.2,7 of 102, Elevations & Sections,Jan 2002_20141104_0001

NATICK LABS

File details come from the government source that posted it. Updated .