B08_Solicitation_Attachment_3_-_Typar_Specifications.pdf
PDF 96 KB Posted
- Attached to
- GLAC 2 MED STP CABIN 1 MATERIALS Federal contract opportunity
- Solicitation number
- 140P1426Q0054
About this file
This is a three-part technical specification for TYPAR® BuildingWrap, a weather-resistive barrier product for exterior wall construction.
The specification requires furnishing and installing a spunbonded polypropylene weather membrane with microporous coating on the exterior side of exterior wall sheathing. The barrier must meet specific performance standards including: Gurley Hill air permeability exceeding 2,500 sec/100cc, water vapor transmission of 9-15 perms per ASTM E96-90 Method A, water penetration resistance greater than 500 cm hydrostatic head per AATCC-127, trapezoidal tear strength of 30/33 per ASTM D5733-9, air infiltration less than 0.02 L/S·M² at 75 PA, and a 24-hour dry indicator rating per ASTM D779. The approved manufacturer is TYPAR® Weather-Protection Membrane by Berry Global, Inc. Installation requires sealing all joints and penetrations with TYPAR® Construction Tape and approved fasteners (plastic cap nails or staples for wood/insulated sheathing, rust-resistant screws with washers for steel frame, and polyurethane-based sealant with masonry fasteners for masonry). All window and door penetrations must be flashed and sealed per ASTM 2112 and AAMA guidelines. The installed barrier must be airtight and free from holes, tears, and punctures, and must be covered with exterior cladding within six months of installation. The product carries a limited warranty as detailed on the manufacturer's website.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P1426Q0054.pdf | ||
| B08_Solicitation_Attachment_2_-_GLAC_-_STP_Cabin_-_Price_Schedule.zip | ZIP file | |
| B08_Solicitation_Attachment_1_-_Specifications_-_GLAC_STP_Cabin.zip | ZIP file |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Made in USA. © 2017, Berry Global, Inc.
TYPAR® is a registered trademark of Berry Global, Inc. or its affiliate.
Please visit TYPAR.com for installation instructions and warranty information.
Building Wraps | Flashings | Construction Tape | Fasteners
ICC #ESR-1404 ∙ CCMC #12884-R ∙ CCMC #12892-R
THREE-PART SPECIFICATIONS
TYPAR® BUILDINGWRAP
1. GENERAL
1.1 Summary
| A. Includes but not limited to: | |
| 1 . Furnish and install weather-resistive barriers on exterior side of exterior wall sheathing as described in Contract Documents. |
1.2 References
| A. ASTM E1677-95 “Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls.” |
| B. ASTM E96-90 “Standard Test Method for Water Transmission of Materials.” |
| C. AATCC-127 “Hydrostatic Head Test.” |
| D. ASTM D5733-9 Trapezoidal Test. |
| E . Air-Ins ASTM E283 Canadian Air Barrier Materials Standard. |
| F . ASTM D779 Dry Indicator Method, Water Penetration Resistance. |
1.3 Submittals
| A. Quality Assurance: | |
| 1 . Submit copies of test results showing performance characteristics equaling or exceeding those specified. |
2. PRODUCTS
2.1 Water-Resistant Barrier
| A. Spunbonded polypropylene weather membrane with a microporous coating, nonwoven, nonperforated. | |
| B. Performance Characteristics: | |
| 1 . Gurley Hill [TAPPI T 460] [sec/100cc] >2500. | |
| 2. Water Vapor Transmission 9-15 perms as tested by ASTM E96-90, Method A. | |
| 3. Water penetration resistance of >500 cm on hydrostatic head in accordance with AATCC-127. | |
| 4. Trapezoidal Test of 30/33 in accordance with ASTM D5733-9. | |
| 5. Air-Ins <.02L/S·M2 @ 75 PA. | |
| 6. Dry Indicator Method ASTM D779 = to 24-hour rating. | |
| C. Approved Manufacturers: | |
| 1 . TYPAR® Weather-Protection Membrane by Berry Global, Inc. www.TYPAR.com | |
| D. Manufacturer’s Warranty: | |
| 1 . Limited product and limited system warranty available depending on the application, see the TYPAR® Weather Protection | |
| System Limited Warranty located at www.TYPAR.com/downloads for warranty details. |
2.2 Sealing Tape/Fasteners
| A. Approved Tape Manufacturers: | |
| 1 . TYPAR® Construction Tape by Berry Global, Inc. | |
| B. Recommended Sealants Against TYPAR® Logo-Side Coating: | |
| 1 . Elastomeric polymer-based, butyl rubber, rubber-based, meeting ASTM C920 evaluation. | |
| C. Recommended Fasteners for Wood, Insulated Sheathing Board, Exterior Gypsum: | |
| 1 . Plastic cap nails. | |
| 2. Plastic cap staples. | |
| D. Recommended Fasteners for Steel Frame Construction: | |
| 1. Rust-resistant screws with washers. | |
| E . Recommended Fastening to Masonry: | |
| 1 . Sealant: Polyurethane-based, meeting ASTM C920 evaluation. | |
| 2. Mechanical: Masonry fastener with washer. |
3. EXECUTION
3.1 Installation
| A. Install in accordance with manufacturer’s instruction over exterior sheathing or open studs. Seal joints and |
| penetrations through weather-resistive barrier with specified tape and fasteners prior to installation of finish material. |
| Air infiltration barrier shall be airtight and free from holes, tears, and punctures. All window and door penetrations |
| are to be flashed and sealed per ASTM 2112, AAMA guidelines and manufacturer instructions. |
| Cover with exterior cladding within six months of installation. |