B08_Solicitation_(Attachment_2_-_Specs_-_Exterior_painting).pdf
PDF 107 KB Posted
- Attached to
- Nicodemus NHS - Tuckpoint Masonry & Painting
- Solicitation number
- 140P6026Q0003
About this file
This is a Performance Work Statement (Section 099113) for exterior painting services at the Nicodemus National Historic Site Township Hall building located at 304 Washington Avenue, Nicodemus, Kansas 67625. The scope encompasses surface preparation and paint application on steel and iron, galvanized metal, and wood substrates. All products must comply with Master Painters Institute (MPI) standards and be listed on the MPI Approved Products List. Paint systems must achieve specific gloss levels ranging from MPI Gloss Level 1 (matte) to Level 7 (high gloss), as defined by ASTM D 523 measurements. Colors are to be selected by the Contracting Officer's Representative (COR) from the manufacturer's full range, matching existing colors on the structure.
Contractors must submit product data including preparation requirements, application instructions, current MPI Approved Products List printouts with proposed products highlighted, Safety Data Sheets (SDS), and paint samples for each color and gloss level. Execution requirements include substrate examination for maximum moisture content (wood: 15 percent; concrete, masonry, and other materials: 12 percent) and compliance with the MPI Maintenance Repainting Manual. Surface preparation involves removing hardware, cleaning substrates of contaminants, addressing lead-based paint per OSHA standards, and applying appropriate primers based on the MPI Degree of Surface Degradation (DSD-1, DSD-2, or DSD-3). For steel and iron, the specification calls for Quick-Dry Enamel System MPI EXT 5.1A with topcoat MPI #81 (alkyd, semi-gloss). For exposed wood framing, Latex over Alkyd Primer System MPI EXT 6.2A is required. For dressed wood including trim, doors, windows, and siding, either Latex over Latex Primer System MPI EXT 6.3L or Latex System over Alkyd Primer System MPI EXT 6.3A is acceptable. All paint applications must be via brush, and power washing on historic structures must be limited and performed carefully to avoid damage.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NICO 311127 6/18/2
[Type here]
Div. 9 V. 2021-10-18 EXTERIOR PAINTING 099113 Page | 1
SECTION 099113
EXTERIOR PAINTING
PART 1 - GENERAL
1.1 SCOPE OF WORK
A. Project Location: Nicodemus National Historic Site (NICO) Township Hall building, 304 Washington Avenue Nicodemus KS 67625. Note Bogue Kansas and Nicodemus Kansas share the same zip code and similar street names. This work is in Nicodemus KS.
B. Building(s) Name/Identifier: Township Hall (Nicodemus Visitor Center)
1.2 SUMMARY
A. Section includes surface preparation and the application of paint systems on the following exterior substrates:
1. Steel and iron.
2. Galvanized metal.
3. Wood.
1.3 DEFINITIONS (Master Painters Institute-MPI)
A. Master Painters Institute (MPI) (http://www.specifypaint.us & http://paintinfo.com/)
B. MPI Gloss Level 1: Not more than five units at 60 degrees and 10 units at 85 degrees, according to ASTM D 523.
C. MPI Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees, according to
ASTM D 523.
D. MPI Gloss Level 4: 20 to 35 units at 60 degrees and not less than 35 units at 85 degrees, according to ASTM D 523.
E. MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D 523.
F. MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D 523.
G. MPI Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D 523.
1.4 ACTION SUBMITTALS
A. Product Data: For each type of product. Include preparation requirements and application instructions.
1. Include printout of current "MPI Approved Products List" for each product category specified, with the proposed product highlighted.
2. Include Safety Data Sheet (SDS).
http://www.specifypaint.us/ http://paintinfo.com/
Div. 9 V. 2021-10-18 EXTERIOR PAINTING
Page | 2
B. Samples: For each type of paint system and each color and gloss of topcoat.
1.5 QUALITY ASSURANCE
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. MPI Listing Manufactures as shown on the MPI Approved Products Lists.
B. Products: Subject to compliance with requirements, provide product listed in the Exterior Painting Schedule for the paint category indicated.
2.2 PAINT, GENERAL
A. MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its "MPI Approved Products Lists."
B. Material Compatibility:
1. Materials for use within each paint system shall be compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.
2. For each coat in a paint system, products shall be recommended in writing by topcoat manufacturers for use in paint system and on substrate indicated.
C. Colors: As selected by Contracting Officer’s Representative (COR) from manufacturer's full range. Matching the existing color.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work.
B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:
1. Concrete: 12 percent.
2. Fiber-Cement Board: 12 percent.
3. Masonry (Clay and CMUs): 12 percent.
4. Wood: 15 percent.
5. Portland Cement Plaster: 12 percent.
6. Gypsum Board: 12 percent.
C. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers.
D. Proceed with coating application only after unsatisfactory conditions have been corrected.
Div. 9 V. 2021-10-18 EXTERIOR PAINTING
Page | 3
1. Application of coating indicates acceptance of surfaces and conditions.
3.2 PREPARATION
A. Comply with manufacturer's written instructions and recommendations in "MPI Maintenance Repainting Manual" applicable to substrates and paint systems indicated.
B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.
1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection.
2. Limit use of power washing on Historic Structures to the extent necessary. Any power washing should be done in a manner to avoid damage to the structure and substrate.
C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease, and incompatible paints and encapsulants.
1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce paint systems indicated.
2. Note presence of encapsulated lead-based paint. Use all precautions required by law and removal methods appropriate to meet OSHA standards. Provide all protective measures necessary for facility to remain occupied during the work and for staff/visitor safety.
Dispose of all debris and protective measures as required by law.
D. Masonry Substrates: Remove efflorescence and chalk. Do not paint surfaces if moisture content or alkalinity of surfaces or mortar joints exceeds that permitted in manufacturer's written instructions.
E. Steel Substrates: Remove rust, loose mill scale, and shop primer if any. Clean using methods recommended in writing by paint manufacturer.
F. Wood Substrates:
1. Scrape and clean knots. Before applying primer, apply coat of knot sealer recommended in writing by topcoat manufacturer for exterior use in paint system indicated.
2. Sand surfaces that will be exposed to view, and dust off.
3. Prime edges, ends, faces, undersides, and backsides of wood.
4. After priming, fill holes and imperfections in the finish surfaces with putty or plastic wood filler. Sand smooth when dried.
3.3 APPLICATION
A. Apply paints according to manufacturer's written instructions and recommendations in "MPI Maintenance Repainting Manual." Apply paints via paint brush
1. Use applicators and techniques suited for paint and substrate indicated.
Div. 9 V. 2021-10-18 EXTERIOR PAINTING
Page | 4
2. Paint surfaces behind movable items same as similar exposed surfaces. Before final installation, paint surfaces behind permanently fixed items with prime coat only.
3. Paint both sides and edges of exterior doors and entire exposed surface of exterior door frames.
4. Paint entire exposed surface of window frames and sashes.
5. Do not paint over labels of independent testing agencies or equipment name, identification, performance rating, or nomenclature plates.
6. Primers specified in painting schedules may be omitted on items that are factory primed or factory finished if acceptable to topcoat manufacturers.
B. If undercoats or other conditions show through topcoat, apply additional coats until cured film has a uniform paint finish, color, and appearance from corner to corner of wall area.
C. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.
3.4 CLEANING AND PROTECTION
A. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by COR, and leave in an undamaged condition.
B. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces.
3.5 EXTERIOR PAINTING SCHEDULE
A. Steel and Iron Substrates:
Primer selection depending on the MPI Degree of Surface Degradation (DSD) evaluation:
DSD-1: Slightly Deteriorated Surface
DSD-2: Moderately Deteriorated Surface
DSD-3: Severely Deteriorated Surface
1. Quick-Dry Enamel System MPI EXT 5.1A
In areas of DSD-1, select Prime Coat to match Topcoat. In areas of DSD-2 and DSD-3, select Prime Coat MPI #76. Minimum recommended surface preparation for MPI #76 is SSPC SP 6 commercial blast, but hand or power tool cleaning may be used in areas inaccessible to abrasive blasting. MPI #76 is primarily applied by airless or conventional spray, but brushing may be required for small areas inaccessible by spray equipment.
a. Prime Coat: Primer to match Topcoat.
b. Topcoat: Alkyd, quick dry, semi-gloss (MPI Gloss Level 5), MPI #81.
Div. 9 V. 2021-10-18 EXTERIOR PAINTING
Page | 5
B. Wood Substrates: Exposed framing.
1. Latex over Alkyd Primer System MPI EXT 6.2A:
a. Prime Coat: Primer, alkyd for exterior wood, MPI #5.
b. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5), MPI #11.
C. Wood Substrates: Dressed Wood (trim, Architectural woodwork, Doors, Windows, Wood board siding and wood fences).
1. Latex over Latex Primer System MPI EXT 6.3L:
a. Prime Coat: Primer, latex for exterior wood, MPI #6.
b. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5), MPI #11.
2. Latex System over Alkyd Primer System MPI EXT 6.3A:
a. Prime Coat: Primer, alkyd for exterior wood, MPI #5.
b. Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5), MPI #11.
END OF SECTION