B08_Solicitation_Attach_2_Drawings_.pdf
PDF 23 MB Posted
- Attached to
- WICA VISITOR CENTER HVAC REMODEL
- Solicitation number
- 140P6325B0007
About this file
These architectural and engineering drawings detail a comprehensive HVAC renovation project for the Wind Cave National Park Visitor Center located at 26611 US Highway 385 in Hot Springs, South Dakota. The 27-page document includes mechanical and electrical plans for a complete HVAC system replacement, covering sub-grade, first, and second floor spaces, with demolition and new installation drawings. The project involves replacing existing VRF (Variable Refrigerant Flow) systems, blower coils, control valves, ductwork, and electrical components across multiple mechanical systems, including air handling units, branch selector boxes, and split system units. Specific equipment to be installed includes Trane VRF blower coils, a heat recovery unit, electric duct heater, and associated electrical infrastructure, with careful coordination required to maintain existing building systems during renovation.
The drawings, prepared by Schemmer engineering firm on January 15, 2025, provide detailed technical specifications, equipment schedules, panel layouts, and power distribution plans. Mechanical scope includes removing and replacing refrigerant piping, control systems, thermostats, and HVAC equipment while maintaining existing building functionality. Electrical work involves updating panel schedules, power connections, and integrating new mechanical equipment into the existing electrical infrastructure. The project emphasizes maintaining the building's operational continuity, with specific notes about coordinating work, preserving existing infrastructure where possible, and ensuring minimal disruption to the national park visitor center's operations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION OF WORK
SITE LOCATION
CONTRACTOR LAY-DOWN AREA
CONTRACTOR PARKING
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
COVER SHEET
NPS WICA HVAC
NPS WICA HVAC
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
01/15/2025
009258005- 0- 0 COVER SHEET
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
GENERAL
0 COVER SHEET
MECHANICAL
M 00 MECHANICAL INFO SHEET
M 01 SHEET SPECIFICATIONS - MECHANICAL
M 02 SHEET SPECIFICATIONS - MECHANICAL
M 03 SHEET SPECIFICATIONS - MECHANICAL
M001 DEMO SUB-GRADE FLOOR PLAN - MECHANICAL
M002 DEMO FIRST FLOOR PLAN - MECHANICAL
M003 DEMO SECOND FLOOR PLAN - MECHANICAL
M101 SUB-GRADE FLOOR PLAN - MECHANICAL
M102 FIRST FLOOR PLAN - MECHANICAL
M103 SECOND FLOOR PLAN - MECHANICAL
M104 ROOF PLAN - MECHANICAL
M401 DETAILS - MECHANICAL
M501 SCHEDULE - MECHANICAL
ELECTRICAL
E 00 ELECTRICAL INFO SHEET
E 01 ELECTRICAL SPECIFICATIONS
E 02 ELECTRICAL SPECIFICATIONS
E 03 ELECTRICAL SPECIFICATIONS
E001 SUB-GRADE FLOOR PLAN - DEMOLITION
E002 FIRST FLOOR PLAN - DEMOLITION
E003 SECOND FLOOR PLAN - DEMOLITION
E201 SUB-GRADE FLOOR PLAN - POWER
E202 FIRST FLOOR PLAN - POWER
E203 SECOND FLOOR PLAN - POWER
E601 EQUIPMENT SCHEDULE
E701 ELECTRICAL PANEL SCHEDULES
E702 ELECTRICAL PANEL SCHEDULES
DRAWING INDEX
NOT TO SCALE
Park Map
NOT TO SCALE
Vicinity Map
NOT TO SCALE
STAGING MAP
DATE INITIAL
1/17/25
A. EXISTING CONDITIONS ARE BASED ON DRAWINGS PROVIDED BY THE OWNER AND
LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT/ENGINEER OF ANY
DISCREPANCIES OR VARIATIONS FROM THOSE SHOWN ON THE DRAWINGS. THE
CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL
EXPENSE TO THE OWNER.
B. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING ENTIRE SET OF DOCUMENTS
TO DETERMINE THEIR FULL SCOPE OF WORK. CONTRACTOR SHALL NOT BE ALLOWED
EXTRA COSTS DUE TO FAILURE TO REVIEW ENTIRE SET OF DOCUMENTS.
C. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR WORK AND BE RESPONSIBLE
FOR SAME. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO
ADDITIONAL EXPENSE TO OWNER. COORDINATE THE WORK AND SHOP DRAWINGS
WITH ALL OTHER TRADES AFFECTED.
D. SCREENED HALF-TONE LINES INDICATE EXISTING CONSTRUCTION TO REMAIN. FULL-
TONE LINES INDICATED NEW OR RELOCATED CONSTRUCTION.
E. CONTRACTOR SHALL COORDINATE THE ROUTING OF ALL DUCTWORK WITH
STRUCTURE, CEILING, LIGHTING, AND PIPING.
F. MAINTAIN MANUFACTURER'S REQUIRED CLEARANCE AROUND ALL EQUIPMENT TO
ALLOW FOR MAINTENANCE ACCESS.
G. ALL PIPING IN CONCEALED LOCATIONS SHALL BE ROUTED AT RIGHT ANGLES AND
PARALLEL TO BUILDING WALLS UNLESS OTHERWISE INDICATED.
H. DO NOT ROUTE DUCTWORK OR PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL
CODE REQUIRED CLEARANCES.
I. IN THE EVENT THE CONTRACTOR ENCOUNTERS ON THE SITE, MATERIAL REASONABLY
BELIEVED TO BE ASBESTOS, LEAD-BASED PAINT, OR ANY OTHER HAZARDOUS
MATERIAL WHICH HAS NOT BEEN RENDERED HARMLESS, THE CONTRACTOR SHALL
IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND REPORT THE CONDITION TO
THE OWNER AND ARCHITECT IN WRITING. THE WORK IN THE AFFECTED AREA SHALL
NOT THEREAFTER BE RESUMED EXCEPT BY WRITTEN AGREEMENT OF THE OWNER
AND CONTRACTOR.
J. ALL RUNOUTS TO AIR TERMINALS SHALL MATCH INLET SIZE UNLESS OTHERWISE
NOTED.
K. ANY UTILITY OR SYSTEM DISRUPTIONS OR OUTAGES DURING CONSTRUCTION SHALL
BE COORDINATED WITH THE OWNER AND GENERAL CONTRACTOR.
A. THE DEMOLITION PLANS WERE PRODUCED BY DUPLICATING THE ORIGINAL DRAWINGS
PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. DIMENSIONS AND
EXISTING CONDITIONS ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY
EXISTING CONDITIONS. ITEMS WHICH ARE INTENDED TO BE REMOVED, RELOCATED,
OR SALVAGED ARE SHOWN AS FULL-TONE LINES. ALL OTHER ITEMS ARE INTENDED TO
REMAIN IN PLACE AND ARE SHOWN AS HALF-TONE.
B. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE ITEMS LISTED BELOW OR
HERE-IN. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED RENOVATION AND
NEW CONSTRUCTION WITH THE EXISTING BUILDING TO IDENTIFY THE TOTAL EXTENT
OF THE DEMOLITION REQUIRED AND AS LISTED BELOW.
C. THE REMOVAL OF FIRE PROTECTION, HVAC, AND PLUMBING EQUIPMENT FROM
FINISHED AREAS AND THROUGH WEATHER BARRIERS SHALL BE COORDINATED WITH
ARCHITECTURAL PLANS AND DETAILS AS WELL AS NOTES ON THE MECHANICAL
DRAWING TO ENSURE PROPER PATCHING AND REPAIR IS MADE TO THE BUILDING.
D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF
ALL EXISTING COMPONENTS, MATERIALS, EQUIPMENT, AND APPURTENANCES TO
BUILD, ERECT, INSTALL, OR ACCOMMODATE ALL NEW CONSTRUCTION WITH THE
OWNER HAVING FIRST RIGHT OF REFUSAL ON ALL ITEMS.
E. ITEMS NOTED TO BE REMOVED AND SALVAGED OR REINSTALLED SHALL BE CAREFULLY
REMOVED BY THE CONTRACTOR WITHOUT DAMAGE AND STORED OR REINSTALLED ON
THE SITE AS DIRECTED. REMOVED OR SALVAGED ITEMS SHALL REMAIN THE
PROPERTY OF THE OWNER.
F. COORDINATE THE DISCONNECTION OF ELECTRICAL MOTORS AND CONTROLS WITH
ELECTRICAL CONTRACTOR PRIOR TO MECHANICAL REMOVALS.
G. IN THE EVENT THE CONTRACTOR ENCOUNTERS ON THE SITE, MATERIAL REASONABLY
BELIEVED TO BE ASBESTOS, LEAD-BASED PAINT, OR ANY OTHER HAZARDOUS
MATERIAL WHICH HAS NOT BEEN RENDERED HARMLESS, THE CONTRACTOR SHALL
IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND REPORT THE CONDITION TO
THE OWNER AND ARCHITECT IN WRITING. THE WORK IN THE AFFECTED AREA SHALL
NOT THEREAFTER BE RESUMED EXCEPT BY WRITTEN AGREEMENT OF THE OWNER
AND ARCHITECT.
H. ANY UTILITY OR SYSTEMS DISRUPTION OR OUTAGES DURING DEMOLITION SHALL BE
COORDINATED WITH THE OWNER AND GENERAL CONTRACTOR.
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M 00
MECHANICAL INFO SHEET
NPS WICA HVAC
009258005- 6- M 00 MECHANICAL INFO SHEET
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
SYMBOL LEGEND
VOLUME DAMPER
DEMO TO EXISTING CONNECTION
SPRINKLER DRAIN
FIRE SUPPRESSION PIPING
ISOLATION VALVE
TAMPER SWITCH
MANUAL BALANCING VALVE
FLOW SWITCH
FIRE DEPARTMENT CONNECTION
CONTROL VALVE (3 WAY)
CONTROL VALVE (2 WAY)
HOSE END DRAIN VALVE
PRESSURE REDUCING VALVE
AUTO FLOW CONTROL VALVE
CHECK VALVE
HVAC DUCTWORK AND SPECIALTIES (CONT.)
MISCELLANEOUS SYMBOLS
RETURN DUCT DOWN
AIR TERMINAL (VERTICAL MOUNTING)
ROUND DUCT UP / DOUBLE LINE PIPE
ROUND DUCT DOWN / DOUBLE LINE
PIPE
RETURN DUCT UP
TURNING VANES
SUPPLY AND FRESH AIR DUCT DOWN
SUPPLY AND FRESH AIR DUCT UP
SIZE/TYPE
SIZE/TYPE
FLOW
FLOW
SIZE/TYPE
FLOW
SMOKE DAMPER
FIRE DAMPER-HORIZ FIRE SEPARATION
MOTORIZED DAMPER-OPPOSED BLADE
MOTORIZED DAMPER-PARALLEL BLADE
ROUND AIR TERMINAL
(HORIZONTAL MOUNTING)
GRAVITY DAMPER
(OR) SAFETY VALVE-STEAM
TEMP & PRESS RELIEF
FLOOR SINK
FLOOR DRAIN
GRADE CLEANOUT
PLUMBING VENT THRU ROOF
CLEANOUT / WALL CLEANOUT
THERMOSTATIC MIXING VALVE
M
M
MANHOLE
TRENCH DRAIN
OVERFLOW ROOF DRAIN
OXYGEN OUTLET
PIPE CAP
ELBOW UP
AIR OUTLET
TEE
ELBOW DOWN
VACUUM OUTLET
ROOF DRAIN
SIZE/TYPE
FLOW
HUMIDISTAT
THERMOSTAT
FLEXIBLE DUCT
S
H
T
TEMPERATURE SENSORUNION
TEE DOWN
STRAINER
EXPANSION JOINT
FLEXIBLE PIPE CONNECTION
AIR VENT
TEE UP
FIRE/SMOKE DAMPER
RECTANGULAR RETURN AIR TERMINAL
(HORIZONTAL MOUNTING)
RECTANGULAR SUPPLY AIR TERMINAL
(HORIZONTAL MOUNTING)
SOLENOID VALVE
F
D
TS
VALVES
FS
M
M
S
LPR
HPS
MPR
MPS
LPS
HVAC PIPING
GHWR
GHWS
HWR
HWS
PC
HPR
ES
BBD BOILER BLOW DOWN
EXHAUST STEAM
PUMPED CONDENSATE
HIGH PRESSURE RETURN
HIGH PRESSURE STEAM
MEDIUM PRESSURE RETURN
MEDIUM PRESSURE STEAM
LOW PRESSURE RETURN
LOW PRESSURE STEAM
GLYCOL HOT WATER RETURN
GLYCOL HOT WATER SUPPLY
HOT WATER RETURN
HOT WATER SUPPLY
FS-_
FD-_
CO
VTR
GCO
ORD-_
MH
X
A
V
RD-_
PIPING SPECIALTIES AND FITTINGS
WCO
FIRE PROTECTION
SIZE/TYPE
FLOW
RECTANGULAR EXHAUST AIR TERMINAL
(HORIZONTAL MOUNTING)
CWS
GCWS
CWR
CR
CS
RL
RDL
RS
GCWR GLYCOL CHILLED WATER RETURN
GLYCOL CHILLED WATER SUPPLY
REFRIGERANT LIQUID LINE
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION LINE
HCWS
HCWR
HOT/CHILLED WATER SUPPLY
HOT/CHILLED WATER RETURN
DOMESTIC HOT WATER
RECIRCULATING (DHWR)
DOMESTIC COLD WATER (DCW)
DOMESTIC HOT WATER (DHW)
ST/OST
PLUMBING PIPING
ACID VENT
TW
AV
AW
W
DS
DSCW
TWR
DSHW
SANITARY VENT
BURIED EXTERIOR WATER
TEPID WATER RECIRCULATING
TEPID WATER
DISTILLED WATER
SOFTENED HOT WATER
SOFTENED COLD WATER
ACID WASTE
STORM DRAIN
SANITARY DRAIN (BELOW FLOOR)
SANITARY DRAIN (ABOVE FLOOR)
OXYGEN
VACUUM
OX
VAC
RO
A
REVERSE OSMOSIS WATER
COMPRESSED AIR
DEIONIZED WATERDI
AIR FLOW STATIONAFS
HPWR
HPWS
HEAT PUMP WATER RETURN
HEAT PUMP WATER SUPPLY
F
S
FS
NEW TO EXISTING CONNECTION
G NATURAL GAS
FOF
FOG
LPG
FOV
FOR
FOS
FUEL OIL RETURN
FUEL OIL SUPPLY
FUEL OIL GAGE
FUEL OIL FILL
FUEL OIL VENT
LIQUEFIED PETROLEUM GAS
CD CONDENSATE DRAIN
EXHAUST DUCT DOWN
EXHAUST DUCT UP
CO CARBON MONOXIDE SENSOR
CO2 CARBON DIOXIDE SENSOR
NO2 NITROGEN DIOXIDE SENSOR
SENSOR WITH GUARD'X'
DOUBLE - GRADE CLEANOUTDGCO
ST/OST STORM DRAIN (BELOW FLOOR)
WASTE AND ANESTHETIC GAS
DISPOSAL
NITROGEN
WAGD
N
MEDICAL AIRMA
PIPE GUIDE
HOSE BIBB
THERMOMETER
PIPE ANCHOR
HB
STEAM TRAP
RHY
WH
ROOF HYDRANT
WALL HYDRANT
PRESSURE GAUGE
EXISTINGDEMO
EXISTINGNEW
18 Ø
18x10
18/10
ROUND DUCT
FLAT OVAL DUCT-1ST FIG IS SIDE
SHOWN
RECT DUCT-1ST FIG IS SIDE SHOWN
ACOUSTICAL DUCT LINER
HVAC DUCTWORK AND SPECIALTIES
HIGH EFFICIENCY TAKEOFF
HIGH EFFICIENCY TAKOFF
WITH VOLUME DAMPER
NITROGEN OUTLET
MEDICAL AIR OUTLET
WASTE AND ANESTHETIC GAS
DISPOSAL OUTLET
N
MA
V
FLEXIBLE DUCTWORK CONNECTION
ABBREVIATIONS
NORTH
ARROW
MATCHLINE
AREA A
AREA B
EXISTING
COLUMN
NEW COLUMN
X
X
X
XXXX
SIM/OPP
X
XXXX
XX-1
X
X
SECTION/
DETAIL
PLAN
DETAIL
REFERENCE NOTE
REFERENCE
DEMOLITION NOTE
EQUIPMENT
NUMBER
ROOM NAME
ROOM / SPACE
NUMBER
LETTER/NUMBER INDICATES NEW
COLUMN LINE
LETTER/NUMBER INDICATES
EXISTING COLUMN LINE
SECTION/DETAIL NUMBER
SHEET NUMBER
INDICATES DIRECTION OF VIEW
DETAIL NUMBER
SHEET NUMBER
REFERENCE
DESIGNATION
DEMOLITION
DESIGNATION
EQUIPMENT
NUMBER
ROOM NAME DESIGNATION
ROOM NUMBER DESIGNATION
REFERENCE LEGEND
NAME
ELEVATION
LEVEL
TITLE
MARKER
VIEW NAME
SCALE: 1/8" = 1'-0"
DRAWING/DETAIL NUMBER
LEVEL CALLOUT DESIGNATION
ELEVATION DESIGNATION
GRAPHIC AREA FOR DRAWING
TITLE
SCALE OF THE DRAWING
XXX-1
PLUMBING FIXTURES
PLUMBING FIXTURE DESIGNATION
X"PIPE
SIZE
PIPE SIZE (DIAMETER)
X"xX"
DUCT SIZE
WIDTH x HEIGHT
X"/X" WIDTH / HEIGHT
X" DIAMETER
REF. DEMO NOTES ( ) XX REF. NOTES ( )
SEE INDIVIDUAL SHEETS FOR REFERENCE NOTES. SEE INDIVIDUAL SHEETS FOR REFERENCE NOTES.
GENERAL DEMOLITION NOTES GENERAL NOTES
MECHANICAL SHEET LIST
NORTH PLAN NORTH TRUE NORTH
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MBH 1000 BTUH
MCA MINIMUM CIRCUIT AMPS
MD MOTORIZED DAMPER
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT
PROTECTION
MPR MEDIUM PRESSURE
RETURN
MPS MEDIUM PRESSURE STEAM
MS MOP SINK
N NITROGEN
NC NORMALLY CLOSED
NO NORMALLY OPEN
NPCW NONPOTABLE COLD WATER
NPHW NONPOTABLE HOT WATER
NPHWR NONPOTABLE HOT WATER
RECIRCULATING
OA OUTSIDE AIR
ORD OVERFLOW ROOF DRAIN
OX OXYGEN
P PUMP
PHC PREHEAT COIL
PIV POST INDICATING VALVE
PRV PRESSURE REGULATING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH,
GAUGE
PTAC PACKAGED TERMINAL AIR
CONDITIONER
RA RETURN AIR
RCP RADIANT CEILING PANEL
RD ROOF AREA DRAINS
RL REFRIGERANT DISCHARGE LINE
RF RETURN FAN
RH RELIEF HOOD
RHC REHEAT COIL
RL REFRIGERANT LIQUID LINE
RLA RELIEF AIR
RLF RELIEF FAN
RO REVERSE OSMOSIS WATER
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION LINE
RTU ROOF TOP UNIT
RV RELIEF VALVE
S SINK
SA SUPPLY AIR
SAN SANITARY SEWER
SD SMOKE DAMPER
SF SUPPLY FAN
SFU SANITARY FIXTURE UNIT
SH SHOWER
SP STATIC PRESSURE
SSS SURGICAL SCRUB SINK
ST STORM WATER
TD TRENCH DRAIN
TMV THERMOSTATIC MIXING VALVE
TONS TONS OF REFRIGERATION
TSP TOTAL STATIC PRESSURE
T THERMOSTAT
UH UNIT HEATER
UR URINAL
V VENT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THRU ROOF
WB WET BULB
WC WATER CLOSETS
WCO WALL CLEANOUT
WF WASH FOUNTAINS
WFU WATER FIXTURE UNITS
WH WALL HYDRANT
WPD WATER PRESSURE DROP
WS WATER SOFTENER
WSHP WATER SOURCE HEAT PUMP
WWHP WATER TO WATER HEAT PUMP
YH YARD HYDRANT
A COMPRESSED AIR
AC AIR COMPRESSOR
AD AIR DOOR
AFCV AUTO FLOW CONTROL VALVE
AHU AIR HANDLING UNIT
AMP AMPERE
APD AIR PRESSURE DROP
AS AIR SEPARATOR
AV ACID VENT
AW ACID WASTE
B BOILER
BC BLOWER COIL
BD BIDET
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VALVE
BHP BRAKE HORSEPOWER
BLKG BLOCKING
BLV BALANCING VALVE
BT BATHTUB
BV BALL VALVE
BW BEDPAN WASHER
CH CHILLER
CC COOLING COIL
CD CONDENSATE DRAIN
CFM CUBIC FEET PER MINUTE
CUH CABINET HEATER
CI CAST IRON
CMU COMBINATION UNITS
CR CONDENSER WATER RETURN
CRAC COMPUTER ROOM AIR
CONDITIONER
CS CONDENSER WATER SUPPLY
CSS CLINICAL SERVICE SINKS
CT COOLING TOWER
CU CONDENSING UNIT - SPLIT SYSTEM
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
DB DRY-BULB TEMPERATURE
DCW DOMESTIC COLD WATER
DEG DEGREE
DF DRINKING FOUNTAIN
DGCO DOUBLE GRADE CLEANOUT
DH EMERGENCY DRENCH HOSES
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RECIRCULATING
DI DEIONIZED WATER
DOAS DEDICATED OUTDOOR AIR SYSTEM
DS DISTILLED WATER
DSA DUCT SOUND ATTENUATORS
DSCW DOMESTIC SOFT COLD WATER
DSHW DOMESTIC SOFT HOT WATER
DSHWR DOMESTIC SOFT HOT WATER
RECIRCULATING
DST DOMESTIC STORAGE TANK
DTW DOMESTIC TEPID WATER
DTWR DOMESTIC TEPID WATER
RECIRCULATING
EA. EACH
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EDH ELECTRIC DUCT HEATER
EEW EMERGENCY EYE WASH
EEWS EMERGENCY EYE
WASH/SHOWER
EF EXHAUST FAN
EFF EFFICIENCY
EFW EMERGENCY FACE WASH
EH EXHAUST HOOD
ERV ENERGY RECOVERY
VENTILATOR
ES EMERGENCY SHOWER
ESP EXTERNAL STATIC PRESSURE
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWT ENTERING WATER
TEMPERATURE
ET EXPANSION TANK
F FIRE SUPPRESSION PIPING
F-_ FURNACE
FCO FLOOR CLEANOUT
FC FLUID COOLER
FCU FAN COIL UNIT
FD FIRE DAMPER
FLA FULL LOAD AMPS
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOOR SINK
FSD FIRE/SMOKE DAMPER
FT FINNED TUBE
G GAS
GCWR GLYCOL CHILLED
WATER RETURN
GCWS GLYCOL CHILLED
WATER SUPPLY
GD GARBAGE DISPOSAL
GDH GAS DUCT HEATER
GHCR GLYCOL HOT/CHILLED
WATER RETURN
GHCS GLYCOL HOT/CHILLED
WATER SUPPLY
GHWR GLYCOL HOT WATER RETURN
GHWS GLYCOL HOT WATER SUPPLY
GI GREASE INTERCEPTOR
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GV GAS VENT
GWH GAS WATER HEATER
HB HOSE BIBB
HC HEATING COIL
HCR HOT/CHILLED WATER RETURN
HCS HOT/CHILLED WATER SUPPLY
ACC AIR COOLED CONDENSER
ACCU AIR COOLED CONDENSING UNIT
ASHP AIR SOURCE HEAT PUMP
ARU AIR ROTATION UNIT
OI OIL INTERCEPTOR
SOI SAND OIL INTERCEPTOR
DSS DUCTLESS SPLIT SYSTEM
SP SUMP PUMP
OST OVERFLOW STORM WATER
WMB WASHING MACHINE BOX
OB OUTLET BOX
RH ROOF HYDRANT
H HUMIDIFIER
DHWP DOMESTIC HOT WATER RECIRCULATING PUMP
DWET DOMESTIC WATER EXPANSION
TANK
HP HORSEPOWER
HPR HIGH PRESSURE RETURN
HPS HIGH PRESURE STEAM
HRC HEAT RECOVERY COIL
HWR HOT WATER RETURN (HEATING)
HWS HOT WATER SUPPLY (HEATING)
HX HEAT EXCHANGER
HY HYDRANTS
HP-_ HEAT PUMP
HVLS HIGH VOLUME LOW SPEED
IH INTAKE HOOD
IRH INFRARED RADIANT HEATER
KH KITCHEN HOOD
KW KILOWATT
KWH KILOWATT HOURS
L LAVATORY
LAT LEAVING AIR TEMPERATURE
LPR LOW PRESSURE RETURN
LPG LIQUIFIED PETROLEUM GAS
LPS LOW PRESSURE STEAM
LRA LOCKED ROTOR AMPS
LS LAUNDRY SINK
LV LOUVER
LWT LEAVING WATER TEMPERATURE
PROJECT MECHANICAL REFERENCED DEMOLITION NOTES PROJECT MECHANICAL REFERENCED NOTES
M 00 MECHANICAL INFO SHEET
M 01 SHEET SPECIFICATIONS - MECHANICAL
M 02 SHEET SPECIFICATIONS - MECHANICAL
M 03 SHEET SPECIFICATIONS - MECHANICAL
M001 DEMO SUB-GRADE FLOOR PLAN - MECHANICAL
M002 DEMO FIRST FLOOR PLAN - MECHANICAL
M003 DEMO SECOND FLOOR PLAN - MECHANICAL
M101 SUB-GRADE FLOOR PLAN - MECHANICAL
M102 FIRST FLOOR PLAN - MECHANICAL
M103 SECOND FLOOR PLAN - MECHANICAL
M104 ROOF PLAN - MECHANICAL
M401 DETAILS - MECHANICAL
M501 SCHEDULE - MECHANICAL
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M 01
SHEET SPECIFICATIONS -
MECHANICAL
NPS WICA HVAC
009258005- 6- M 01 SHEET SPECIFICATIONS - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M 02
SHEET SPECIFICATIONS -
MECHANICAL
NPS WICA HVAC
009258005- 6- M 02 SHEET SPECIFICATIONS - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M 03
SHEET SPECIFICATIONS -
MECHANICAL
NPS WICA HVAC
009258005- 6- M 03 SHEET SPECIFICATIONS - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
M
M
M
(E)XUH-005
(E)XUH-004
(E)XUH-002
(E)XUH-001
(E)AHU-1
(E)AHU-2
(E)XUH-003
(E) P-1
(E) P-2
(E) RE-1
CWS
CWR
HWS
HWR
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M001
DEMO SUB-GRADE FLOOR
PLAN - MECHANICAL
NPS WICA HVAC
009258005- 6- M001 DEMO SUB-GRADE FLOOR PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. DEMO NOTES ( ):X
1 REMOVE EXISTING OUTDOOR VRF UNIT AND ALL ASSOCIATED REFRIGERANT PIPING AND
ACCESSORIES. HOUSEKEEPING PAD TO BE REUSED.
2 EXISTING HWS/HWR PIPING SERVING VAV SYSTEM TO REMAIN.
3 CONTRACTOR TO REMOVE EXISTING CONTROL VALVE. PREPARE FOR INSTALLATION OF NEW
CONTROL VALVE. SEE CONSTRUCTION PLANS AND SCHEDULES FOR ADDITIONAL
INFORMATION. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF CONTROL VALVES.
4 REMOVE EXISTING OUTDOOR AIR MOTORIZED DAMPER AT INLET OF (E) AHU-2. CONTRACTOR
TO RECORD SIZE AND VOLTAGE FOR REPLACEMENT.
SCALE: 1/8" = 1'-0"
SUB-GRADE PLAN - DEMO HVAC PIPING
VRF NOTE:
- CONTRACTOR TO RECORD AND DOCUMENT ALL EXISTING
VRF PIPE ROUTING PRIOR TO REMOVAL. NEW PIPING IS TO
BE INSTALLED IN SPACE OF REMOVED PIPING.
(TYP.)
(TYP.)
DATE INITIAL
TRUE
NORTH
PLAN
NORTH
M
M M
M
M M M
M
M
M
M
M
M
M
M
T
T
T
T
T
T T
T T
T
T
T
T
T
T
(E)XFT-115
(E)XFT-114(E)XFT-113(E)XFT-111(E)XFT-110
(E)XFT-116
(E)XFT-112
(E)XFT-106(E)XFT-104
(E)XFT-102
(E)XFT-103
(E)XFT-109
(E)XFT-108
(E)XFT-107
3 3
(E)XFT-118
(E)XCUH-102
HWS
HWR
HW
R
HW
S
HW
S
HW
R
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M002
DEMO FIRST FLOOR PLAN -
MECHANICAL
NPS WICA HVAC
009258005- 6- M002 DEMO FIRST FLOOR PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. DEMO NOTES ( ):X
1 REMOVE EXISTING BLOWER COIL AND ASSOCIATED REFRIGERANT PIPING. ASSOCIATED
CONDENSATE PIPING TO REMAIN.
2 REMOVE EXISTING BRANCH SELECTOR BOX AND ASSOCIATED REFRIGERANT PIPING.
3 CONTRACTOR TO REMOVE EXISTING CONTROL VALVE. PREPARE FOR INSTALLATION OF NEW
CONTROL VALVE. SEE CONSTRUCTION PLANS AND SCHEDULES FOR ADDITIONAL
INFORMATION. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF CONTROL VALVES.
4 EXISTING HWS/HWR PIPING SERVING VAV SYSTEM TO REMAIN.
5 REMOVE EXISTING THERMOSTAT AND PREPARE FOR NEW THERMOSTAT INSTALLATION. IF
THERMOSTAT IS NOT INSTALLED AT 48" A.F.F. PACK WALL AND PREPARE FOR ADJACENT.
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - DEMO HVAC PIPING
VRF NOTE:
- CONTRACTOR TO RECORD AND DOCUMENT ALL EXISTING
VRF PIPE ROUTING PRIOR TO REMOVAL. NEW PIPING IS TO
BE INSTALLED IN SPACE OF REMOVED PIPING.
DATE INITIAL
TRUE
NORTH
PLAN
TT
T
T
T
T
T
T
T
T
T
T
(E)XFT-220
(E)XFT-219
(E)XCUH-201
(E)XFT-212(E)XFT-211
(E)XFT-208
(E)XFT-206(E)XFT-204(E)XFT-203
(E)XFT-202
(E)XFT-201 (E)XFT-205
(E)XFT-207
(E)XFT-210(E)XFT-209 (E)XFT-213
(E)XFT-218
(E)XFT-214 (E)XFT-215
(E)XFT-216
(E)XFT-217
(E)H-1
Auditorium
GIFT SHOP
OFFICE
M003
HW
S
HWR
HW
R
HWS
MUSEUM COLL.
STORAGE
(E)H-1
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M003
DEMO SECOND FLOOR
PLAN - MECHANICAL
NPS WICA HVAC
009258005- 6- M003 DEMO SECOND FLOOR PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. DEMO NOTES ( ):X
1 REMOVE EXISTING BLOWER COIL AND ASSOCIATED REFRIGERANT PIPING. ASSOCIATED
CONDENSATE PIPING TO REMAIN.
2 REMOVE EXISTING BRANCH SELECTOR BOX AND ASSOCIATED REFRIGERANT PIPING.
3 EXISTING HWS/HWR PIPING SERVING VAV SYSTEM TO REMAIN.
4 HUMIDIFIER AND ASSOCIATED DUCTWORK/PIPING TO REMAIN.
5 EXISTING RETURN GRILLE TO REMAIN.
6 EXISTING SUPPLY DUCTWORK TO BE REUSED.
7 HUMIDIFIER GRID AND ASSOCIATED PIPING TO REMAIN.
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - DEMO HVAC PIPING
VRF NOTE:
- CONTRACTOR TO RECORD AND DOCUMENT ALL EXISTING
VRF PIPE ROUTING PRIOR TO REMOVAL. NEW PIPING IS TO
BE INSTALLED IN SPACE OF REMOVED PIPING.
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - DEMO HVAC
DATE INITIAL
TRUE
NORTH
PLAN
M
M
T
(E)VAV-101
(E)VAV-102
(E)VAV-201
(E)VAV-103
(E)XUH-001
(E)VAV-104
(E)VAV-105
(E)XUH-002
(E)XUH-003
(E)XUH-005
(E)XUH-004
(E)AHU-1
(E)AHU-2
CV-107CV-106
CV-105
BS-001
HRV-1
WEIGHT ROOM
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
MECH/ELEC/TELE
VRF UP
VRF UP
VRF
VRF
VRF
HWS UP TO (E)
XFT-108, 109
HWS UP TO (E)
XFT-107
HWS
HWR
HWR
HWS
BC-100A, 100B
BC-100A
BC-100B
CWS
HWR
HWS
CWR
CWS
CWR
SF-2
HWC-2
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \a p o s p is il\
D o c u m e n ts
\R e v it te m p \0
-M E
C H
R a p o s p is il@ s c h e m m e r.
c o m .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M101
SUB-GRADE FLOOR PLAN -
MECHANICAL
NPS WICA HVAC
009258005- 6- M101 SUB-GRADE FLOOR PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. NOTES ( ):X
1 INSTALL HRV-1 ON EXISTING HOUSEKEEPING PAD.
2 PROVIDE ALUMINUM JACKETING FOR ALL VRF PIPING ON EXTERIOR OF BUILDING.
3 REPLACE SUPPLY FAN (SF-2) AND HOT WATER COIL (HWC-2) SERVING (E) AHU-2.
CONTRACTOR TO MATCH EXISTING PARAMETERS. SEE SCHEDULE FOR MORE DETAILS.
4 INSTALL NEW OA MOTORIZED DAMPER SERVING INLET OF (E) AHU-2. CONTRACTOR TO
MATCH EXISTING SIZE AND VOLTAGE. UNIT IS TO HAVE FAIL-CLOSED OPERATION AND BE
CONNECTED TO EXISTING BAS SYSTEM.
SCALE: 1/8" = 1'-0"
SUB-GRADE PLAN - HVAC PIPING
VRF NOTE:
- VRF SYSTEM IS SHOWN AS A SCHEMATIC LAYOUT.
- VRF SYSTEM IS TO BE THREE-PIPE REFRIGERANT FLOW SYSTEM.
- CONTRACTOR IS TO SIZE AND INSTALL VRF PIPING PER MANUFACTURER'S REQUIREMENTS.
- CONTRACTOR IS TO ROUTE PIPING IN THE SAME SPACE PREVIOUSLY USED FOR VFR WHEN POSSIBLE.
DATE INITIAL
TRUE
NORTH
PLAN
M
M
M
M
M
M
M
M
MMM
M
M M
M
T
T
T
T
T
T
T
T
T
T
T
T T
T
T BC-105
BC-111
BC-106 BC-107
BC-110
BC-108
BC-112
BC-109
BC-102
BC-103
BC-104
(E)P-3
(E)P-4
BC-101
(E)ET
(E)XCUH-101
(E)XFT-106
(E)XFT-112
(E)XFT-116
(E)XFT-115
(E)XFT-114(E)XFT-113(E)XFT-111(E)XFT-110
(E)XCUH-102
(E)XFT-109
(E)XFT-108
(E)XFT-118
(E)XFT-107
(E)XFT-104
(E)XFT-102
(E)XFT-103
(E)XFT-117
LIBRARY
OFFICE
DRAFTING
STOR
OFFICE
OFFICE
WOMEN
MEN
HALL
BOILER ROOM
READY ROOM
ADMIN. STOR
PHONE
EVIDENCE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CV-209
HWR
HWS
CV-201
CV-101
CV-204
CV-205
CV-202
CV-203
CV-102
(E)XFT-105
CV-104
CV-112
CV-211
CV-212
CV-110CV-109
CV-210
ELEV
MEN
WOMEN
OFFICE
OFFICE
STORAGE
DECK
MAINTENANCE
CV-207
CV-108 IN
CABINET
CV-111
CV-103 IN
CABINET
1 VR
F
VRF DN
VRF DN
VRF
VRF
BC-104
BC-103
BC-101
BC-102
BC-111
BC-105
BC-106
BC-107
BC-108
BC-112
BC-110
BC-109
CD
HWR
HW
S
HW
R
HWS
HWR
HW
S
HW
R
HWS
HWR HWR
HWS
HW
S
HW
R
HWS
HW
R
HWR
HWS
(E)BP-1
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M102
FIRST FLOOR PLAN -
MECHANICAL
NPS WICA HVAC
009258005- 6- M102 FIRST FLOOR PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. NOTES ( ):X
1 NEW BLOWER COIL TO BE INSTALLED IN EXISTING BLOWER COIL LOCATION. EXISTING
CONDENSATE LINE TO BE CONNECTED TO NEW BLOWER COIL.
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - HVAC PIPING
VRF NOTE:
- VRF SYSTEM IS SHOWN AS A SCHEMATIC LAYOUT.
- VRF SYSTEM IS TO BE THREE-PIPE REFRIGERANT FLOW SYSTEM.
- CONTRACTOR IS TO SIZE AND INSTALL VRF PIPING PER MANUFACTURER'S REQUIREMENTS.
- CONTRACTOR IS TO ROUTE PIPING IN THE SAME SPACE PREVIOUSLY USED FOR VFR WHEN POSSIBLE.
DATE INITIAL
TRUE
NORTH
PLAN
TT
T
T
T
T
T
T
T
T
T
T
T H
BC-203
BC-201
BC-202
(E)XFT-201 (E)XFT-205
(E)XFT-202
(E)XFT-204 (E)XFT-206(E)XFT-203
(E)XFT-208
(E)XFT-211 (E)XFT-212
(E)XCUH-201
(E)XFT-220
(E)XFT-219
(E)VAV-210
VAV-207
(E)VAV-208
VAV-209
SS-1
(E)H-1
(E)VAV-206
(E)VAV-205
(E)VAV-204
(E)VAV-202
(E)VAV-203(E)XFT-207
(E)XFT-209 (E)XFT-210
(E)XFT-213
(E)XFT-218
(E)XFT-214 (E)XFT-215
(E)XFT-216
(E)XFT-217
EXHIBIT
Auditorium
BALCONY
MEN'S
JANITOR'S
WOMEN'S
ELEV
MUSEUM COLL.
STORAGE
VENDING &
SEATING
GIFT SHOP
OFFICE
GIFT SALES
ADMINISTRATION
SUPERINTENDENT
OFFICE
RANGER ROOM
FOYER
RESTROOM
207A
SUPPLIES
207B
VENDING
STORAGE
RECEPTION
EXHIBIT
EXHIBIT
VR
F
UP TO SSCU-1
ON ROOF
VRF
VRF
RS/RL
3/4" CD
EXHIBIT
BC-203
BC-202
BC-201
HWR HWR
HWR
HWS
HW
S
HWS
M103
MUSEUM COLL.
STORAGE
12x8 SA
12x8 RA
SS-1
12x8 SA
(E)H-1
EDH-15
6 7
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M103
SECOND FLOOR PLAN -
MECHANICAL
NPS WICA HVAC
009258005- 6- M103 SECOND FLOOR PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. NOTES ( ):X
1 NEW BLOWER COIL TO BE INSTALLED IN EXISTING BLOWER COIL LOCATION. EXISTING
CONDENSATE LINE TO BE CONNECTED TO NEW BLOWER COIL.
2 SIZE AND INSTALL REFRIGERANT PIPING PER MANUFACTURER'S REQUIREMENTS AND THE
SPECIFICATIONS. ALL PIPE PENETRATIONS SHALL BE DONE VIA A CORE DRILL TO BE NEAT
AND CLEAN.
3 EXISTING HUMIDIFIER STEAM GRID AND ASSOCIATED PIPING TO REMAIN.
4 EXTEND 3/4" CD FROM SS-1 TO EXISTING CONDENSATE LINE.
5 PROVIDE 48" STRAIGHT RUN UPSTREAM AND DOWNSTREAM FROM EDH-1.
6 CONNECT RA DUCT TO EXISTING RA GRILLE.
7 PROVIDE COMBINATION THERMOSTAT AND HUMIDISTAT TO SERVE SS-1 SYSTEM.
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - HVAC PIPING
VRF NOTE:
- VRF SYSTEM IS SHOWN AS A SCHEMATIC LAYOUT.
- VRF SYSTEM IS TO BE THREE-PIPE REFRIGERANT FLOW SYSTEM.
- CONTRACTOR IS TO SIZE AND INSTALL VRF PIPING PER MANUFACTURER'S REQUIREMENTS.
- CONTRACTOR IS TO ROUTE PIPING IN THE SAME SPACE PREVIOUSLY USED FOR VFR WHEN POSSIBLE.
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - HVAC
DATE INITIAL
TRUE
NORTH
PLAN
(E)CH-1
SSCU-1
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M104
ROOF PLAN - MECHANICAL
NPS WICA HVAC
009258005- 6- M104 ROOF PLAN - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
REF. NOTES ( ):X
1 INSTALL UNIT ON 12" PATE ROOF CURB OR EQUAL. SEE DETAILS FOR ADDITIONAL
INFORMATION.
SCALE: 1/8" = 1'-0"
ROOF PLAN - HVAC PIPING
DATE INITIAL
TRUE
NORTH
PLAN
INSULATION
THREADED ROD
INSULATION
THREADED ROD
HANGER, INSULATION ON PIPE
CONTINUOUS THROUGH HANGER
WITHOUT SWALLOWING
PIPE, 1"Ø MAX
BAND
THREADED ROD
HANGER
INSULATION
PIPE
SHIELD TO COVER 180° OF PIPE,
SEE CHART FOR LENGTH
SEE CHART
SHIELD LENGTH
SEE CHART
SHIELD LENGTH,
SWIVEL
SHIELD LENGTH FOR PIPE - NOT LESS THAN THE FOLLOWING:
a. NPS 1/4" TO 3-1/2" 12" LONG AND .048" THICK
b. NPS 4" 12" LONG AND .06" THICK
c. NPS 5" TO 6" 18" LONG AND .06" THICK
d. NPS 8" TO 14" 24" LONG AND .075" THICK
e. NPS 16" TO 24" 24" LONG AND .105" THICK
NOTE:
1. PIPES NPS 8" AND LARGER: INCLUDE WOOD OR REINFORCED CALCIUM-SILICATE-INSULATION INSERTS OF LENGTH AT LEAST AS LONG AS PROTECTIVE SHIELD.
2. THERMAL-HANGER SHIELDS: INSTALL WITH INSULATION SAME THICKNESS AS PIPING INSULATION.
SHIELD TO COVER 180° OF
PIPE, SEE CHART FOR
LENGTH
SHIELD TO COVER 180° OF
PIPE, SEE CHART FOR
LENGTH
THREADED ROD
U-BOLT (TYP.) UNISTRUT OR STEEL ANGLE WITH
LONG LEG DOWN
SHIELD TO COVER 360° OF PIPE,
SEE CHART FOR LENGTH HANGER, INSULATION ON PIPE
CONTINUOUS THROUGH HANGER
WITHOUT SWALLOWING
PIPE (TYP.)
FLOORS
E
E N
O T
E S
B E
L O
W
T Y
P
IC
A L
L Y
A
.F .F
TYPICAL HVAC CONTROL DEVICE INSTALLATION
THERMOSTAT
OR OTHER HVAC
CONTROL DEVICE
LIGHT
SWITCH
NOTES:
1. WHEN THERMOSTAT IS LOCATED ADJACENT TO LIGHT SWITCH OR OTHER WALL MOUNTED
ELECTRICAL OR CONTROL DEVICE, DEVICES TO BE INSTALLED AT THE SAME ELEVATION.
2. ALL USER INPUT BUTTONS OR SWITCHES ON CONTORL DEVICE TO BE LOCATED BELOW 48"
A.F.F. TO MEET ADA REQUIREMENTS.
3. WHEN INSTALLED NEAR DOOR, LIGHT SWITCH SHALL BE DEVICE CLOSEST TO DOOR FRAME.
4. IF DEVICE IS LOCATED ABOVE COUNTER, INSTALL AT 40" A.F.F.
CL
LIQUID AND SUCTION LINES DOWN
TO INDOOR UNIT
INSULATE REFRIGERANT LINES
CONTINUOUSLY THROUGH
PENETRATION. SEAL
PENETRATION WEATHER TIGHT.
ROOF
CONDSENSING UNIT
METAL CURB CAP
FASTEN CONDENSING UNIT
SECURELY TO CURB CAP
PREFRABRIACTED ROOF CURB
TOTAL
HEIGHT
OF TRAP
TO FLOOR DRAIN
TOTAL HEIGHT OF TRAP:
X + H + (1 1/2 x PIPE DIAMETER)
H = AT LEAST 1 INCH PLUS
CASING STATIC PRESSURE
X = 1/2 "H"
COIL CONDENSATE DRAIN
PAN
SLOPE DOWN
X
H
CLEAN OUT
HOUSEKEEPING PAD, HEIGHT IS
BASED ON TRAP HEIGHT
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \s ra a b e \D o c u m e n ts \0
-M E
C H
R s ra a b e Q
Y
Y L .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M401
DETAILS - MECHANICAL
NPS WICA HVAC
009258005- 6- M401 DETAILS - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
SCALE: NOT TO SCALE
PIPE HANGER DETAIL
SCALE: 12" = 1'-0"
THERMOSTAT DETAIL
SCALE: NOT TO SCALE
CONDENSING UNIT SUPPORT/ PIPING THROUGH ROOF DETAIL
SCALE: NOT TO SCALE
CONDENSATE DRAIN TRAP NEGATIVE STATIC PRESSURE
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \a p o s p is il\
D o c u m e n ts
\R e v it te m p \0
-M E
C H
R a p o s p is il@ s c h e m m e r.
c o m .r v t
AJP
SXR
JEK
01/15/2025
009258.005
M501
SCHEDULE - MECHANICAL
NPS WICA HVAC
009258005- 6- M501 SCHEDULE - MECHANICAL
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
2. VRF SYSTEM IS TO BE INTEGRATED INTO EXISTING JOHNSON CONTROLS BAS SYSTEM.
NOTES: 1. FIELD COORDINATE EXACT SYSTEM PIPING ARRANGEMENT.
BS-001 SEE PLANS 16 116.4 208 1 60 1.5/1.7 20 TRANE TCMBG1016SJ21N4 1,2
MAX CAP TOTAL MBH VOLTS PH HZ MCA MOPMARK LOCATION NO. OF PORTS
COOLING ELECTRICAL
MANUFACTURER AND MODEL NUMBER REMARKS
BRANCH SELECTOR SCHEDULE
4. CONTROL VALVE LISTED AS SUPPLEMENTARY SHALL BE CONTROLLED BY AN AUXILLARY HEATING RELAY FROM THE THERMOSTAT SERVING PRIMARY HEATING DEVICE.
3. CONTROL VALVE LISTED AS PRIMARY HEATING FUNCTION SHALL BE CONTROLLED BY IT'S OWN THERMOSTAT.
2. VALVE IS TO BE TWO-WAY VALVE WITH BRONZE BODY AND FLOATING POINT CONTROL. VALVE IS TO BE FAIL-OPEN TYPE.
NOTES: 1. VALVE IS TO BE CONNECTED TO BACNET BAS.
CV-212 2-WAY XFT-219 PRIMARY N/A 0.5 1 1,2,4
CV-211 2-WAY XFT-220 PRIMARY N/A 0.75 1 1,2,3
CV-210 2-WAY XFT-214,215,216,217 SUPPLEMENTARY (E) VAV-206 8 1-1/4 1,2,4
CV-209 2-WAY XFT-213,218 PRIMARY N/A 1 1-1/4 1,2,3
CV-208 2-WAY XFT-211,212 SUPPLEMENTARY (E) VAV-205 4 1-1/4 1,2,4
CV-207 2-WAY XFT-209,210 SUPPLEMENTARY (E) VAV-204 4 1-1/4 1,2,4
CV-206 2-WAY XFT-208 SUPPLEMENTARY (E) VAV-203 4 1-1/4 1,2,4
CV-205 2-WAY XFT-207 PRIMARY N/A 0.5 1 1,2,3
CV-204 2-WAY XFT-205 PRIMARY N/A 0.5 1-1/4 1,2,3
CV-203 2-WAY XFT-206 PRIMARY N/A 0.5 1 1,2,3
CV-202 2-WAY XFT-203,204 SUPPLEMENTARY BC-203 2 1 1,2,4
CV-201 2-WAY XFT-201,202 SUPPLEMENTARY BC-201 2 1 1,2,4
CV-113 2-WAY XFT-106 SUPPLEMENTARY BC-110 0.75 1 1,2,4
CV-112 2-WAY XFT-112 SUPPLEMENTARY BC-111 0.5 1 1,2,4
CV-111 2-WAY XFT-116 SUPPLEMENTARY BC-109 1.5 1-1/4 1,2,4
CV-110 2-WAY XFT-113,114,115 SUPPLEMENTARY BC-112 2 1-1/4 1,2,4
CV-109 2-WAY XFT-111 SUPPLEMENTARY BC-108 0.5 1-1/4 1,2,4
CV-108 2-WAY XFT-110 SUPPLEMENTARY BC-107 0.5 1-1/4 1,2,4
CV-107 2-WAY XFT-108,109 SUPPLEMENTARY BC-103 3.75 1-1/4 1,2,4
CV-106 2-WAY XFT-107 SUPPLEMENTARY BC-104 1.25 1-1/4 1,2,4
CV-105 2-WAY XFT-118 PRIMARY N/A 1.25 1 1,2,3
CV-104 2-WAY XFT-105 SUPPLEMENTARY BC-101 0.5 1 1,2,4
CV-103 2-WAY XFT-117 SUPPLEMENTARY BC-102 1.5 1 1,2,4
CV-102 2-WAY XFT-104 PRIMARY N/A 0.5 1 1,2,3
CV-101 2-WAY XFT-101,102,103 PRIMARY N/A 2.25 1-1/4 1,2,3
MARK TYPE SERVES HEATING FUNCTION PRIMARY HEATING DEVICE FLOW GPM
EXISTING LINE
SIZE (IN.) REMARKS
CONTROL VALVE SCHEDULE
4. PROVIDE UNIT WITH SCR CONTROL.
3. PROVIDE UNIT FACTORY DISCONNECT SWITCH.
2. UNIT IS TO BE CONTROLLED BY SPLIT SYSTEM DEHUMIDICATION SEQUENCE.
NOTES: 1. UNIT IS TO BE CONNECTED TO EXISTING BACNET BAS SYSTEM.
EDH-1 SS-1 320 1.5 208 3 60 GREENHECK IDHB 1,2
KW VOLTS PH HZMARK SERVES
AIRFLOW
(CFM)
HEATER ELECTRICAL DATA
MANUFACTURER AND MODEL
NUMBER REMARKS
ELECTRIC DUCT HEATER SCHEDULE
NOTES: 1. CONTRACTOR TO PROVIDE AND INSTALL DIRECT REPLACEMENT OF EXISTING AHU-2 SUPPLY FAN. CONTRACTOR TO VERIFY AND MATCH ALL EXISTING FAN PARAMETERS PRIOR TO ORDERING.
SF-2 MECH RM. AHU-2 HORIZONTAL DRAW THRU 675 1.0 1.93 2142 1750 1 208 3 SEE NOTE 1 1
TYPE CFM
EXT SP
(IN WG)
TOTAL SP
(IN WG) RPM RPM HP VOLTS PH
MARK LOCATION SERVES
FAN DATA ELECTRICAL DATA (60 HZ AC)
BASIS OF DESIGN NOTES
FAN SCHEDULE
5. UNIT IS TO HAVE INTEGRAL DISCONNECT.
4. UNIT IS TO HAVE INTEGRAL CONDENSATE PUMP.
3. PROVIDE UNIT WITH REMOTE WALL MOUNTED THERMOSTAT. INSTALL AT 48" A.F.F.
2. VRF SYSTEM IS TO BE INTEGRATED INTO EXISTING JOHNSON CONTROLS BAS SYSTEM.
NOTES: 1. SCHEDULED CAPACITIES ARE BASED ON 80/67 RA AND 95/75 AMBIENT OA CONDITIONS FOR COOLING, 70/60 RA AND 50/45 AMBIENT OA CONDITIONS FOR HEATING.
BC-203 WALL MOUNT BS-001 270 R-410A 11.6 13.1 208 1 60 0.24 15 TRANE TPKFYP012LM140B 1,2,3,4,5
BC-202 WALL MOUNT BS-001 270 R-410A 11.6 13.1 208 1 60 0.24 15 TRANE TPKFYP012LM140B 1,2,3,4,5
BC-201 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-112 WALL MOUNT BS-001 321 R-410A 14.6 16.5 208 1 60 0.24 15 TRANE TPKFYP015LM140B 1,2,3,4,5
BC-111 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-110 WALL MOUNT BS-001 270 R-410A 11.6 13.1 208 1 60 0.24 15 TRANE TPKFYP012LM140B 1,2,3,4,5
BC-109 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-108 WALL MOUNT BS-001 216 R-410A 7.8 8.7 208 1 60 0.24 15 TRANE TPKFYP008LM140B 1,2,3,4,5
BC-107 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-106 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-105 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-104 WALL MOUNT BS-001 174 R-410A 5.8 6.5 208 1 60 0.24 15 TRANE TPKFYP006LM140B 1,2,3,4,5
BC-103 WALL MOUNT BS-001 399 R-410A 17.5 19.4 208 1 60 0.24 15 TRANE TPKFYP018LM140B 1,2,3,4,5
BC-102 WALL MOUNT BS-001 216 R-410A 7.8 8.7 208 1 60 0.24 15 TRANE TPKFYP008LM140B 1,2,3,4,5
BC-101 WALL MOUNT BS-001 270 R-410A 11.6 13.1 208 1 60 0.24 15 TRANE TPKFYP012LM140B 1,2,3,4,5
BC-100B WALL MOUNT BS-001 216 R-410A 7.8 8.7 208 1 60 0.24 15 TRANE TPKFYP008LM140B 1,2,3,4,5
BC-100A WALL MOUNT BS-001 216 R-410A 7.8 8.7 208 1 60 0.24 15 TRANE TPKFYP008LM140B 1,2,3,4,5
RATED CAP TOTAL MBH RATED CAP TOTAL MBH VOLTS PH HZ MCA MOPMARK TYPE
BRANCH SELECTOR
BOX
NOMINAL
CFM REFRIGERANT
COOLING HEATING ELECTRICAL
MANUFACTURER AND MODEL NUMBER REMARKS
VRF BLOWER COIL SCHEDULE
NOTES: 1. CONTRACTOR TO PROVIDE DIRECT REPLACEMENT OF EXISTING COIL. CONTRACTOR TO FIELD VERIFY COIL SIZE AND CONNECTION DIMENSIONS PRIOR TO ORDERING.
HWC-2 MECH. RM AHU-2 675 0.05 331 1 14 x 21 12 -10 68 58.3 200 180.3 6.3 6.8 DAIKIN 1
EAT DB (°F) LAT DB (°F) EWT (°F) LWT (°F) FLOW (GPM) WPD FTMARK LOCATION SERVES CFM
APD
(IN WG)
MAX FV
(FPM) MIN ROWS SIZE H x W (IN) FPI
AIRSIDE DATA
MIN CAP MBH
WATERSIDE DATA
MANUFACTURER AND MODEL
NUMBER REMARKS
HOT WATER HEATING COIL SCHEDULE
5. PROVIDE UNIT WITH PANEL HEATER AND LOW AMBIENT KIT.
4. PROVIDE UNIT WITH SNOW/HAIL GUARDS.
3. VRF SYSTEM IS TO BE INTEGRATED INTO EXISTING JOHNSON CONTROLS BAS SYSTEM.
2. FIELD COORDINATE EXACT SYSTEM PIPING ARRANGEMENT IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS.
NOTES: 1. PROVIDE UNIT WITH 24" MANUFACTURER STAND. ANCHOR UNIT TO CONCRETE HOUSEKEEPING PAD WITH VIBRATION ISOLATORS.
HRV-1 SEE PLANS BS-001 R-410A 155.2 172.7 126 -18 66/64 110/100 208 3 60 TRANE TURYP1683N40A 1,2,3,4,5
MCA MOP VOLT PH HZMARK LOCATION SERVES REF TYPE
NOMINAL
CAP CLG (MBH)
NOMINAL CAP
HTG (MBH)
COOLING
AMBIENT TEMP
(°F)
HEATING
AMBIENT TEMP
(°F)
ELECTRICAL DATA
MANUFACTURER AND MODEL NUMBER REMARKS
HEAT RECOVERY UNIT SCHEDULE
7. PROVIDE UNIT WITH CONTROLLER FOR DEHUMIDIFICATION MODE. UNIT IS TO BE CONNECTED TO EDH-1.
6. PROVIDE UNIT WITH BACNET CONTROLLER. UNIT IS TO BE INTEGRATED INTO JOHNSON CONTROLS SYSTEM.
5. PROVIDE UNIT WITH MICROBLUE CONDENSATE PUMP IF UNIT DOES NOT HAVE INTEGRAL CONDENSATE LIFT MECHANISM.
4. PROVIDE UNIT WITH HEAT PUMP WIND BAFFLES.
3. PROVIDE UNIT WITH 12" PATE ROOF CURB OR EQUAL.
2. PROVIDE WITH HARD WIRED, WALL MOUNTED THERMOSTAT.
NOTES: 1. PROVIDE WITH FACTORY INSULATED REFRIGERANT LINESETS SIZED PER MANUFACTURER REQUIREMENTS.
SS-1 MUSEUM STORAGE 321 80 67 11.6 21.8 13.6 9.8 - MITSUBISHI PEAD-A12AA9 SSCU-1 ROOF 95 R410A MITSUBISHI PUZ=A12NKA7 11 28 208 1 60 1-7
DB WB
AIRSIDE DATA EAT (°F)
MIN CAP (MBH)
EFFICIENCY
(SEER)
MIN CAP @ 47°F
(MBH)
EFFICIENCY
(HSPF) ELEC HEAT (KW) MCA MOCP VOLTS PH HZLOCATION
SUPPLY
AIR
CFM
COOLING COIL DATA HEATING DATA
MANUFACTURER AND MODEL
NUMBER MARK LOCATION
AMB TEMP
(°F) REFER TYPE
MANUFACTURER AND MODEL
NUMBERMARK
INDOOR UNIT DATA OUTDOOR UNIT DATA
ELECTRICAL DATA
REMARKS
SPLIT SYSTEM AIR CONDITIONING SCHEDULE
GENERAL EQUIPMENT NOTE:
-AIRFLOWS AND CAPACITIES ARE SCHEDULED FOR OPERATION AT 4100.0 FEET ABOVE SEA LEVEL.
A. SEE ARCHITECTURAL SHEETS FOR EXACT AREAS AND WALLS
AFFECTED BY THE DEMOLITION AND REMODEL.
B. ITEMS WHICH ARE INTENDED TO BE REMOVED, RELOCATED, OR
SALVAGED ARE SHOWN AS FULL-TONE LINES ON DEMO PLANS. ALL
OTHER ITEMS ARE INTENDED TO REMAIN IN PLACE AND ARE SHOWN
AS HALF-TONE.
C. DEMOLITION SHOWN IS AS REQUIRED FOR THE COMPLETE PROJECT.
THE CONTRACTOR SHALL COORDINATE THE DEMOLITION EFFORT PER
THE PHASING PLANS. COORDINATE DEMOLITION WITH THE WORK OF
OTHER TRADES. PROVIDE TEMPORARY POWER AND LIGHTS AS
REQUIRED TO ALLOW THE WORK OF OTHER TRADES TO PROCEED OR
AS REQUIRED TO ALLOW THE OWNER TO OCCUPY THE SPACE.
D. ALL OF THE EQUIPMENT AND DEVICES SHOWN ON THIS DRAWING ARE
EXISTING. THE LOCATIONS OF THE EQUIPMENT AND DEVICES WERE
OBTAINED FROM EXISTING DRAWING AND FIELD INVESTIGATION. THE
LOCATIONS OF THE EXISTING EQUIPMENT AND DEVICES ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR. ACCURACY OF THE
INFORMATION SHOWN IS NOT GUARANTEED. THE CONTRACTOR IS
RESPONSIBLE FOR THE VERIFICATIONS OF ALL EXISTING CONDITIONS
PRIOR TO SUBMITTING BIDS. SITE VISITS PRIOR TO SUBMISSION OF
BIDS NEED TO BE FULLY COORDINATED WITH THE OWNER.
E. CIRCUIT INFORMATION FOR ALL AFFECTED CIRCUITS SHALL BE
VERIFIED PRIOR TO COMMENCING WORK. ACCURACY OF THE
INFORMATION SHOWN AND INCLUDED ON THE PANEL SCHEDULES IS
NOT GUARANTEED.
F. LUMINAIRES AND DEVICES INDICATED TO BE REMOVED, WHICH ARE
LOCATED ON CEILINGS OR WALLS, SHALL HAVE LUMINAIRES, DEVICE
AND ALL ASSOCIATED CIRCUIT WIRING AND CONDUIT REMOVED BACK
TO NEAREST JUNCTION BOX, OR DEVICE NOT INDICATED TO BE
REMOVED. ACTUAL CIRCUITING MUST BE DETERMINED IN THE FIELD.
THE CONTRACTOR SHALL PROVIDE ALL NECESSARY WIRE, CONDUIT,
DEVICES AND CONNECTIONS NECESSARY TO ENSURE CIRCUIT
CONTINUITY OF THE REMAINING DEVICES.
G. THE OWNER HAS THE RIGHT TO RETAIN ALL SALVAGEABLE MATERIAL.
ANY MATERIAL THE OWNER CHOOSES NOT TO ACCEPT SHALL BE
REMOVED FROM THE SITE AND PROPERLY DISPOSED OF BY THE
CONTRACTOR. CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF
ANY PCB BALLAST OR HAZARDOUS LAMPS.
H. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE
LABELING OF SPARE OR ABANDONED CIRCUITS AND/OR CIRCUIT
BREAKERS IN ALL PANELS AFFECTED BY THE DEMOLITION. SPARE
CIRCUITS AND/OR CIRCUIT BREAKERS MAY BE REUSED FOR THE
CIRCUITING OF THE NEW OR REMODELED AREA AS SPACE AND PANEL
LOADING WILL ALLOW.
I. THE CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR THE
PROPER RESTORATION OF ALL EXISTING SURFACES REQUIRING
PATCHING, PLASTERING, PAINTING AND/OR OTHER REPAIR DUE TO
THE DEMOLITION WORK DONE BY THE ELECTRICAL CONTRACTOR,
UNDER THE TERMS OF THIS SPECIFICATION. CLOSE AND SEAL ALL
OPENINGS, REPAIR ALL SURFACES, ETC., AS REQUIRED.
J. FIRE ALARM DEVICES SHALL BE REMOVED, REPLACED AND
CONNECTED TO NEW FIRE ALARM SYSTEM AS SPECIFIED. DUCT
SMOKE DETECTORS AND FIRE SMOKE DAMPERS SHALL BE REMOVED
ONLY WHEN THE ASSOCIATED MECHANICAL EQUIPMENT IS BEING
REMOVED.
K. EXISTING FIRE ALARM DEVICES, EMERGENCY LIGHTS AND EXIT SIGNS
SHALL BE COMPLETE AND OPERABLE AT ALL TIMES. PROVIDE
TEMPORARY DEVICES IN AREAS BEING WORKED ON TO ALLOW FOR A
WORKABLE SYSTEM DURING CONSTRUCTION.
L. PROVIDE MINIMUM [2] DAYS ADVANCE NOTICE OF OUTAGES.
COORDINATE WITH OWNER FOR ALL ANTICIPATED OUTAGES. OWNER
HAS FINAL APPROVAL ON TIME AND EXTENT OF POWER OUTAGE.
M. PROTECT EXISTING FURNITURE, CARPET AND OTHER
APPURTENANCES FROM DAMAGE DURING THE COURSE OF
CONSTRUCTION. REPLACE DAMAGED ITEMS FREE OF COST TO THE
OWNER.
A. ALL DEVICES SHOWN SHALL BE MOUNTED AT 18" A.F.F. UNLESS
INDICATED OTHERWISE.
B. ALL AUXILIARY CABLE ABOVE CEILING SHALL BE PLENUM RATED
WHERE REQUIRED.
C. CEILING MOUNTED DEVICES SHALL BE CENTERED IN CEILING TILE
WHERE INSTALLED IN ACOUSTICAL TILE CEILING.
D. PROVIDE 120 VOLT POWER CIRCUIT(S) FOR AUXILIARY SYSTEMS AS
REQUIRED FOR COMPLETE AND OPERATIONAL SYSTEMS.
A. DRAWINGS DO NOT SHOW TOTAL NUMBER OF CONDUCTORS FOR
CIRCUITS REQUIRED. PROVIDE THE NUMBER OF CONDUCTORS
NEEDED TO COMPLETE INSTALLATION OF SPECIFIC EQUIPMENT
FURNISHED. A GREEN GROUND CONDUCTOR, SIZED PER NEC, SHALL
ALSO BE INCLUDED IN EACH CIRCUIT. ADJUST CONDUCTOR SIZES AS
NEEDED TO LIMIT VOLTAGE DROP TO LEVELS RECOMMENDED BY
NEC. THE CONTRACTOR SHALL ALSO COORDINATE INSPECTIONS
WITH THE AHJ.
B. SEE ARCHITECTURAL SHEETS FOR REFLECTED CEILING PLANS.
C. ALL CIRCUITS SHALL HAVE SEPARATE NEUTRAL WIRES BUT CAN
SHARE AN INSULATED GREEN GROUND WIRE IN MINIMUM 3/4" EMT
CONDUIT.
D. NO BOXES SHALL BE MOUNTED BACK TO BACK.
E. CONTRACTOR TO SEAL ALL PENETRATIONS THROUGH FIRE OR
FIRE/SMOKE RATED WALLS AND FLOORS.
F. ALL RACEWAYS SHALL BE SEALED AS REQUIRED BY NEC AND NFPA.
G. CABLE AND CONDUIT SHALL NOT INTERFERE WITH EQUIPMENT
ACCESS.
H. ALL CABLING ABOVE CEILING SHALL BE PROPERLY SUPPORTED (NOT
FROM CEILING SYSTEM).
I. CONTRACTOR SHALL COORDINATE FINAL PANEL DIRECTORIES WITH
OWNER.
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
305107
80043
C U s e rs \d la n g h o ld t\ D o c u m e n ts
\R e v it te m p \0
-E
L E
C
R d la n g h o ld tT W
S
J .r v t
DJL
DJL
JCB
01/15/2025
009258.005
E 00
ELECTRICAL INFO SHEET
NPS WICA HVAC
009258005- 7- E 00 ELECTRICAL INFO SHEET
WIND CAVE NATIONAL PARK
26611 US HIGHWAY 385
HOT SPRINGS, SD
D1 MECHANICAL EQUIPMENT TO BE REMOVED. DEMOLISH ALL
ASSOCIATED CONDUIT, CONDUCTORS, AND CONTROL WIRING.
D2 MECHANICAL EQUIPMENT TO BE REMOVED AND REPLACED
IN-PLACE. MAINTAIN ALL ASSOCIATED CONDUIT AND
CONDUCTORS FOR NEW EQUIPMENT CONNECTION.
D3 ASSOCIATED UNIT SUPPLY FAN AND HEATING COIL TO BE
REPLACED IN-KIND. COORDINATE WITH MECH FOR
DISCONNECTION OF POWER. MAINTAIN CONDUIT AND
CONDUCTORS FOR REPLACEMENT COMPONENT RECONNECTION.
1 CONNECT MECHANICAL EQUIPMENT TO EXISTING
CIRCUIT/CONDUCTORS AT THIS LOCATION.
2 ASSOCIATED UNIT SUPPLY FAN AND HEATING COIL TO BE
REPLACED IN-KIND. COORDINATE WITH MECH FOR
RECONNECTION OF POWER. RECONNECT DEVICES TO EXISTING
CIRCUIT/CONDUCTORS.
E 00 ELECTRICAL INFO SHEET
E 01 ELECTRICAL SPECIFICATIONS
E 02 ELECTRICAL SPECIFICATIONS
E 03 ELECTRICAL SPECIFICATIONS
E001 SUB-GRADE FLOOR PLAN - DEMOLITION
E002 FIRST FLOOR PLAN - DEMOLITION
E003 SECOND FLOOR PLAN - DEMOLITION
E201 SUB-GRADE FLOOR PLAN - POWER
E202 FIRST FLOOR PLAN - POWER
E203 SECOND FLOOR PLAN - POWER
E601 EQUIPMENT SCHEDULE
E701 ELECTRICAL PANEL SCHEDULES
E702 ELECTRICAL PANEL SCHEDULES
S
SYMBOL LEGEND
P C
J
J
O S
MS
IC
S
S
M
N
T V
VC
N E
N S
N
N D
N 2
G
K1
V
A
F
F
F
F
F S
D
P S
T S
R
M
M
T
DH
WALL MOUNTED STRIP LUMINAIRE
SYMBOL NOTES:
STROBE
HORN
MANUAL PULL STATION
HORN STROBE
PHOTOCELL
VOICE AND DATA
JUNCTION BOX - CEILING MOUNT
JUNCTION BOX - WALL MOUNT
VOICE OUTLET
DATA OUTLET
OCCUPANCY SENSOR
MOTION SENSOR
CEILING FAN
HEAT DETECTOR
SMOKE DETECTOR
REMOTE INDICATOR LIGHT
SPRINKLER TAMPER SWITCH
DUCT SMOKE DETECTOR
FLOW SWITCH
POST INDICATING VALVE SWITCH
POLE MOUNTED SITE LUMINAIRE
NURSE CALL
SPEAKER
BEDSIDE STATION
INTERCOM SPEAKER STATION
VOLUME CONTROL STATION
MICROPHONE JACK
TELEVISION OUTLET
CCTV CAMERA
SOUND, TELEVISION, AND SECURITY
FUSE
EMERGENCY PULL STATION
DISCONNECT SWITCH
STAFF STATION
DUTY STATION
DOME LIGHT
MASTER STATION
EMERGENCY GENERATOR
POWER DISTRIBUTION ONE LINE
CONDUIT UP
CONDUIT DOWN
INDICATES BUSHED CONDUIT
VOICE/DATA OUTLET
DOUBLE BED BEDSIDE STATION
DRAW OUT VACUUM
CIRCUIT BREAKER
LIGHTNING SURGE ARRESTOR
THERMAL OVERLOAD RELAY
PLUG-IN OR DRAWOUT
CONNECTOR
CIRCUIT BREAKER
FUSED DISCONNECT SWITCH
VOLTMETER
AMMETER
X:Y
CURRENT TRANSFORMER -
(RATIO)
KIRK KEY INTERLOCK
MAGNETIC DOOR HOLDER
"C" INDICATES CEILING MOUNTED
"F" INDICATES FLOOR MOUNTED
"S" INDICATES SURFACE MOUNTED
"G" INDICATES GROUND FAULT INTERRUPTING
"IG" INDICATES ISOLATED GROUND
"AC" INDICATES MOUNTING 6" ABOVE COUNTERTOP
OR BACKSPLASH
"WP" INDICATES WEATHERPROOF
"XP" INDICATES EXPLOSION PROOF
"U" INDICATES USB CHARGER
"R" INDICATES EXISTING DEVICE REMOVED AND
RELOCATED
LOWER CASE LETTER BY SWITCHES AND FIXTURES
INDICATE ASSOCIATED UNIT FOR SWITCHING
LIGHTING
LUMINAIRE
WALL MOUNTED LUMINAIRE
RECESSED LUMINAIRE
WALL MOUNTED LUMINAIRE
SURFACE MOUNTED LUMINAIRE
TRACK LIGHTING
DIMMER SWITCH
TIMER SWITCH
WIRING DEVICES - SWITCHES
SINGLE POLE SWITCH
KEY OPERATED SWITCH
SINGLE POLE SWITCH WITH PILOT
THERMAL ELEMENT SWITCH
FOUR-WAY SWITCH
TWO POLE SWITCH
THREE-WAY SWITCH
STRIP / INDUSTRIAL LUMINAIRE
LUMINAIRE - NIGHT LIGHTING
LUMINAIRE - EMERGENCY SYSTEM
EMERGENCY BATTERY PACK LUMINAIRE
REMOTE EMERGENCY HEAD
WALL WASH LUMINAIRE
PENDANT MOUNTED LUMINAIRE
POWER POLE
METER SOCKET
POWER EQUIPMENT
WIRING DEVICES - RECEPTACLES
COMBINATION STARTER SAFETY SWITCH
RELAY - CONTROL AS NOTED
PUSHBUTTON STATION
MOTOR CONNECTION
SIMPLEX RECEPTACLE
DUPLEX RECEPTACLE
QUADRUPLEX RECEPTACLE
EMERGENCY RECEPTACLE
SPECIAL PURPOSE RECEPTACLE, NEMA
CONFIGURATION NOTED
PLUG-IN STRIP - LENGTH AND QUANTITY OF
OUTLETS AS SHOWN
SAFETY SWITCH
DROP CORD RECEPTACLE ASSEMBLY
FUSIBLE SWITCH (FUSETRON)
PANELS AND CABINETS
DISTRIBUTION PANEL
SWITCHBOARD, SWITCHGEAR, MCC
EQUIPMENT OR TERMINAL CABINET
DRY TYPE TRANSFORMER
BRANCH CIRCUIT PANEL
CONDUIT AND BOXES
FIRE ALARM SYSTEM
HORN (PA, PUBLIC ADDRESS)
TRANSFORMER
EXIT LIGHT - WALL MOUNT WITH DIRECTIONAL
ARROWS AS INDICATED, FILLED-IN QUARTERS
INDICATE ILLUMINATION SIDES
EXIT LIGHT - CEILING OR PENDANT MOUNT
WITH DIRECTIONAL ARROWS AS INDICATED,
FILLED-IN QUARTERS INDICATE ILLUMINATION
SIDES
EMERGENCY EXIT LIGHT COMBO
LOW VOLTAGE MOMENTARY CONTACT
SWITCH
H
S
S
N P PILLOW SPEAKER
FB FLOOR BOX
FP FLOOR POKE-THROUGH DEVICE
N M
WIRELESS ACCESS POINT
S
S2
S3
S4
SD
SK
SP
STE
ST
SFT
X
CONTROLLED RECEPTACLE
WB WALL AV BOX
F SPEAKER STROBES
F SPEAKERS
RC ROOM CONTROLLER
PP POWER PACK
ABBREVIATIONS
TEL TELEPHONE
TEMP TEMPERATURE
TVSS TRANSIENT VOLTAGE
SURGE SUPPRESSOR
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS
LABORATORIES
UPS UNINTERRUPTIBLE
POWER SYSTEM
VFD VARIABLE FREQUENCY
DRIVE
W WEST
W/ WITH
W/O WITHOUT
WHM WATTHOUR METER
WT WEIGHT
XFMR TRANSFORMER
ACSR ALUMINUM CONDUCTOR
STEEL REINFORCED
AFF ABOVE FINISH FLOOR
AIC AMPS INTERRUPTING
CAPACITY (SYM RMS)
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
APPROX APPROXIMATE
AUTO AUTOMATIC
AVG AVERAGE
L ANGLE
BKR BREAKER
C OR CL CENTER LINE
C OR CND CONDUIT (ELECTRICAL
SHEETS)
CKT CIRCUIT
CLG CEILING
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CPT CONTROL POWER TRANSFORMER
DC DIRECT CURRENT
DEG DEGREE
DEMO DEMOLITION
DIA DIAMETER
DIM DIMENSION
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DWG DRAWING
E EAST
EA EACH
EL OR
ELEV
ELEVATION - GRADE OR
BUILDING
ELEC ELECTRIC OR
ELECTRICAL
ELEV ELEVATOR
EMD ESTIMATED MAXIMUM
DEMAND
ENCL ENCLOSURE
EQUIP EQUIPMENT
EST ESTIMATE
EWC ELECTRIC WATER
COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FLA FULL LOAD AMPS
FLEX FLEXIBLE
FLUOR FLUORESCENT
AWG GAUGE
HP HORSE POWER
HR HOUR
HTG HEATING
HTR HEATER
HZ HERTZ
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAEP FIRE ALARM EXTENDER PANEL
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
CUH CABINET UNIT HEATER
EMI ELECTROMAGNETIC INTERFERENCE
SOUTH
SCHED SCHEDULE
SF SQUARE FOOT (FEET)
SPEC SPECIFICATIONS
SPKR SPEAKER
SQ SQUARE
STD STANDARD
STL STEEL
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
S
GFI GROUND FAULT CIRCUIT
INTERRUPTER
SCCR SHORT CIRCUIT CURRENT RATING
SPD SURGE PROTECTIVE DEVICE
SPDT SINGLE POLE, DOUBLE THROW
VFC VARIABLE FREQUENCY
CONTROLLER
ID INSIDE DIAMETER
IES ILLUMINATING
ENGINEERING SOCIETY
IN INCH
INSUL INSULATION
INT INTERIOR
KCMIL KCM KILO CIRCULAR MIL
KV KILOVOLTS
KVA KILOVOLT AMPERES
KVAR KILOVOLT AMPERES
REACTIVE
KW KILOWATT
LBS POUNDS
LRA LOCKED ROTOR AMPS
LTG LIGHTING
QTY QUANTITY
REC RECEPTACLE
REFR REFRIGERATOR
REINF REINFORCEMENT
REQD REQUIRED
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
N NORTH
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE
PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO NUMBER
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
OH OVERHEAD
OPNG OPENING
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PSI POUNDS PER SQUARE IN.
MCCB MOLDED CASE CIRCUIT BREAKER
OCPD OVERCURRENT PROTECTIVE DEVICE
RFI RADIO FREQUENCY INTERFERENCE
REF. DEMO NOTES ( )
PROJECT ELECTRICAL REFERENCED DEMOLITION NOTES
X
DX
PROJECT ELECTRICAL REFERENCED NOTES
NORTH
ARROW
MATCHLINE
AREA A
AREA B
EXISTING
COLUMN
NEW COLUMN
X
X
X
XX-XX
SIM
X
XX-XX
XXXX
DX
X
SECTION/
DETAIL
PLAN
DETAIL
REFERENCE NOTE
REFERENCE
DEMOLITION NOTE
EQUIPMENT
NUMBER
ROOM NAME
150 SF
ROOM
NUMBER
LETTER INDICATES NEW
COLUMN LINE
LETTER INDICATES EXISTING
COLUMN LINE
SECTION/DETAIL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .