B08_Solicitation_Attach_2_Drawing.pdf

PDF 19 MB Posted

Attached to
BADL Remodel Collection Storage Federal contract opportunity
Solicitation number
140P6323B0014
Issued by
Department of the Interior National Park Service Midwest Region

View the file

Other files for this federal contract opportunity

Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NO.

AutoCAD SHX Text

PMIS

AutoCAD SHX Text

OF

AutoCAD SHX Text Date

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text

REVISION

AutoCAD SHX Text Initial

AutoCAD SHX Text 05-03-2023

AutoCAD SHX Text

AMM/KES

AutoCAD SHX Text

BADLANDS NATIONAL PARK INTERIOR, SD

AutoCAD SHX Text

AutoCAD SHX Text 137 80111

AutoCAD SHX Text

AutoCAD SHX Text 237 636 --

AutoCAD SHX Text

AMM/KES

AutoCAD SHX Text G0.0

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

%%UGENERAL NOTES:

AutoCAD SHX Text IF INSTANCES ARISE DURING CONSTRUCTION OF THIS PROJECT THAT REQUIRE PENETRATIONS OF STRUCTURAL MEMBERS DUE TO METHODS OF ROUTING DUCTS, PIPES, ETC. DIFFERENT FROM ROUTING SHOWN ON THE DRAWINGS, COSTS FOR PENETRATION OF STRUCTURAL MEMBERS SHALL BE BORN BY THE CONTRACTOR REQUIRING THE PENETRATION. BEFORE PENETRATION THROUGH A STRUCTURAL MEMBER CAN BE MADE, THE CONTRACTOR SHALL INFORM THE C.O.R. OF HIS/HER INTENT AND SHALL AWAIT INSTRUCTIONS FROM THE C.O.R. AS TO EXACT PLACEMENT OF, AND DETAILS FOR, SUCH PENETRATIONS.

AutoCAD SHX Text THE CONTRACTOR SHALL PERFORM ALL TESTS AS SPECIFIED OR AS NECESSARY TO DEMONSTRATE COMPLETE AND SATISFACTORY INSTALLATIONS OF ALL SYSTEMS PROVIDED UNDER THIS CONTRACT.

AutoCAD SHX Text

ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES.

AutoCAD SHX Text IN SOME INSTANCES, THERMAL AND SOUND BATT INSULATION HAS BEEN OMITTED FROM THE DETAILS FOR CLARITY. SEE WALL TYPES.

AutoCAD SHX Text CONTRACTOR SHALL REVIEW CONTRACT REQUIREMENTS AND PROCEDURES OUTLINED IN THE SPECIFICATIONS. THE WORK OUTLINED IN THE DRAWINGS AND SPECIFICATIONS SHALL BE INCORPORATED INTO THE GENERAL CONTRACT. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS, METHODS AND MEANS REQUIRED TO EXECUTE THE GENERAL CONTRACT AND PROVIDE A FINISHED PRODUCT.

AutoCAD SHX Text VERIFY MECHANICAL AND ELECTRICAL CONDITIONS FOR SCOPE AND INTERFACE. CONTRACTOR SHALL COORDINATE LOCATION FOR ALL MECHANICAL AND ELECTRICAL ITEMS WITH GENERAL CONSTRUCTION. REVIEW ANY DISCREPANCIES WITH C.O.R. PRIOR TO INSTALLATION AND/OR FABRICATION.

AutoCAD SHX Text ALL DIMENSIONS ARE TO FACE OF FINISHED WALL, UNLESS NOTED OTHERWISE. REVIEW PLACEMENT OF WALLS WITH DETAILS AND FURNISHINGS, CASEWORK OR MECHANICAL AND ELECTRICAL ITEMS AND CLEARANCES. REVIEW ANY DISCREPANCIES WITH C.O.R. PRIOR TO CONSTRUCTION AND/OR FABRICATION. ALL DIMENSIONS ARE FOR BIDDING PURPOSES ONLY. ACTUAL FIELD DIMENSIONS SHALL BE VERIFIED PRIOR TO SUBMITTING SHOP DRAWINGS, ORDERING RELATED MATERIALS, DEMOLITION OR CONSTRUCTION.

AutoCAD SHX Text EXTEND ALL STUDS, GYPSUM WALLBOARD (GWB) AND ACOUSTICAL BATTS TO STRUCTURE, UNLESS OTHERWISE NOTED OR DETAILED.

AutoCAD SHX Text PROVIDE WOOD BLOCKING BEHIND ALL WALL STOPS, FINISH TRIM, BUILDING HARDWARE AND TOILET ACCESSORIES TO BE MOUNTED ON WALLS. PROVIDE CONTINUOUS WOOD BLOCKING HORIZONTALLY AND VERTICALLY, BEHIND ALL WALL HUNG EQUIPMENT, ACCESSORIES, COUNTERS AND ANY OTHER BUILDING MATERIALS REQUIRING ANCHORING TO WALLS, CEILINGS AND FLOORS. VERIFY WITH ALL TRADES FOR THESE ITEMS PRIOR TO COVERING THE STRUCTURE. ALSO, PROVIDE WOOD BLOCKING IN WALLS FOR OWNER PROVIDED AND INSTALLED ARTWORK, COORDINATE LOCATIONS WITH OWNER.

AutoCAD SHX Text ALL GYPSUM WALLBOARD (GWB) NOTED OR SCHEDULED ON THE DRAWINGS SHALL BE SUSPENDED AND/OR SUPPORTED WITH FRAMING IN ACCORDANCE WITH INDUSTRY STANDARDS WHERE NOT SPECIFICALLY DETAILED OR OTHERWISE SPECIFIED.

AutoCAD SHX Text WHENEVER GWB ABUTS A MASONRY WALL, HOLD CASING BEAD 3/16" AWAY FROM EXISTING WALL FACE AND PROVIDE CASING BEAD ON EDGE OF GWB AND CAULK THE 3/16" REVEAL. PAINT TO MATCH EXISTING WALL COLOR UNLESS NOTED OTHERWISE.

AutoCAD SHX Text

ALL WOOD STUDS ARE 2X4 UNLESS NOTED OTHERWISE.

AutoCAD SHX Text ALL DEMOLITION WORK IS TO BE COORDINATED WITH NEW WORK. IF UNDOCUMENTED CONDITIONS EXIST THAT ARE AFFECTED BY NOTED DEMOLITION, CONTACT THE CONTRACTING OFFICER BEFORE PROCEEDING.

AutoCAD SHX Text

ALL MATERIALS SHALL BE NEW UNLESS SPECIFICALLY NOTED OTHERWISE.

AutoCAD SHX Text 20.

AutoCAD SHX Text IT IS THE INTENT OF THIS CONTRACT THAT ALL AREAS AFFECTED BY CONSTRUCTION BE A FINISHED & COMPLETE PROJECT. CONTRACTOR SHALL PATCH, REPAIR, AND ADJUST AS REQUIRED TO ACHIEVE THIS FINISHED PROJECT.

AutoCAD SHX Text 21.

AutoCAD SHX Text 22.

AutoCAD SHX Text 23.

AutoCAD SHX Text

ALL ANGLES ON PLAN ARE 90 DEGREES OR 45 DEGREES UNLESS NOTED OTHERWISE.

AutoCAD SHX Text 14.

AutoCAD SHX Text ALL MECHANICAL OPENINGS AND OTHER OPENINGS OR PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO MAINTAIN RATINGS. PENETRATIONS AT EXTERIOR SHALL BE INSULATED AND SEALED WEATHER TIGHT. INTERIOR PENETRATIONS THAT ARE EXPOSED TO ADJACENT SPACES SHALL BE SEALED.

AutoCAD SHX Text 16.

AutoCAD SHX Text 17.

AutoCAD SHX Text 18.

AutoCAD SHX Text 19.

AutoCAD SHX Text 15.

AutoCAD SHX Text 13.

AutoCAD SHX Text 12.

AutoCAD SHX Text 11.

AutoCAD SHX Text 10.

AutoCAD SHX Text 9.

AutoCAD SHX Text 6.

AutoCAD SHX Text 5.

AutoCAD SHX Text 4.

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text CONTRACTOR IS URGED TO VISIT THE SITE AND REVIEW CONDITIONS PRIOR TO BIDDING. NO ADDITIONAL SCOPE SHALL BE APPROVED FOR ITEMS ABLE TO BE OBSERVED DURING A PRE-BID SITE VISIT.

AutoCAD SHX Text CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS FOR WORKABILITY, ADJACENT CONDITIONS, EFFECTS AND ACCESSIBILITY. ALL DIMENSIONS ARE FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS PRIOR TO ORDERING RELATED MATERIALS OF CONSTRUCTION.

AutoCAD SHX Text

AREAS NOTED AS N.I.C. ARE NOT IN CONTRACT.

AutoCAD SHX Text 7.

AutoCAD SHX Text CONTRACTOR SHALL CONTACT THE C.O.R. IN THE EVENT THAT UNFORESEEN CONDITIONS ARE ENCOUNTERED.

AutoCAD SHX Text 8.

AutoCAD SHX Text PROTECT ALL SITE LOCATIONS THAT ARE NOT DESIGNATED FOR REMOVAL. ANY DAMAGE CAUSED BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. THIS INCLUDES CURBS, PAVING, TURF DISTURBANCE, EQUIPMENT, VEGETATION ETC...

AutoCAD SHX Text 3.

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR SECURING THE CONSTRUCTION AREA AND SHALL BE RESPONSIBLE FOR DAMAGES/THEFT RESULTING FROM NEGLECT AND UNAUTHORIZED ACCESS VIA THE CONSTRUCTION SITE. COORDINATE SECURITY MEASURES WITH C.O.R. AND PARK STAFF.

AutoCAD SHX Text ALL DIMENSIONS ARE FOR BIDDING PURPOSES ONLY, AND SHALL BE VERIFIED AND COORDINATED WITH NEW CONSTRUCTION.

AutoCAD SHX Text COORDINATE WITH MECHANICAL AND ELECTRICAL SHEETS FOR INFORMATION REGARDING NEW MECHANICAL PLUMBING AND ELECTRICAL ITEMS THAT REQUIRE EXISTING FLOOR, CEILING, ROOF AND WALL REMOVAL. ALSO, SEE MECHANICAL AND ELECTRICAL SHEETS FOR REMOVAL OF ALL MECHANICAL, PLUMBING AND ELECTRICAL ITEMS. ALL PLUMBING FIXTURES, LIGHTING FIXTURES AND OUTLETS SHALL BE CAPPED BELOW SLABS IN ACCORDANCE WITH PREVAILING CODE REQUIREMENTS.

AutoCAD SHX Text DISCONNECT AND CAP ALL SERVICES (ELECTRICAL, MECHANICAL, AND PLUMBING) IN EXISTING WALLS, FLOORS, AND CEILINGS TO BE REMOVED

AutoCAD SHX Text THIS IS AN OCCUPIED BUILDING AND SHALL ONLY BE ACCESSED DURING PLANNED WORK HOURS AND REQUIRES NPS SUPERVISION DURING WORK HOURS. SEE DIVISION 1 FOR ADDITIONAL DETAILS.

AutoCAD SHX Text REMOVE ALL WALLS, DOORS, WINDOWS, AND OTHER ITEMS SHOWN BOLD/DASHED IN THE DRAWINGS. VERIFY THE SCOPE OF DEMOLITION WITH THE NEW CONSTRUCTION DRAWINGS. CONTRACTOR SHALL REMOVE ANY WALL OR ITEM NOT SPECIFICALLY DESIGNATED OR NOTED THAT WOULD BE REQUIRED TO PROVIDE A FINISHED PRODUCT AS PER THE PLANS AND SPECIFICATIONS.

AutoCAD SHX Text SEE DEMOLITION DRAWINGS FOR SALVAGE ITEMS. INVENTORY AND FORMALLY TURN OVER TO OWNER AT LOCATION DETERMINED BY OWNER OR LEAVE IN PLACE PER DIRECTION OF COR.

AutoCAD SHX Text THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING MATERIALS TO REMAIN RESULTING FROM WORK UNDER THIS CONTRACT, AND SHALL RESTORE SUCH DAMAGE TO ITS ORIGINAL CONDITION.

AutoCAD SHX Text ALL WALLS INDICATED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY, INCLUDING ALL ELECTRICAL OUTLETS, SWITCHES, AND CONDUITS, TELEPHONE OUTLETS, WIRING, MECHANICAL PIPING, BASES AND PLUMBING, ETC.

AutoCAD SHX Text ALL WINDOWS INDICATED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY, INCLUDING ALL WINDOW TREATMENTS ETC., UNLESS NOTED OTHERWISE. ALL WINDOW TREATMENTS ARE TO BE SALVAGED AND CONTRACTOR SHALL RE-INSTALL AS NOTED.

AutoCAD SHX Text

COORDINATE ALL DEMOLITION WORK BETWEEN ALL TRADES.

AutoCAD SHX Text CONTRACTOR SHALL NOTIFY C.O.R. IF DEMOLITION WORK APPEARS TO AFFECT THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING BEFORE PROCEEDING.

AutoCAD SHX Text ALL INFORMATION SHOWN ON THE DEMOLITION PLAN, INCLUDING DOORS, WALLS, CHASES, EQUIPMENT, CEILINGS, ARE NOT INTENDED TO REPRESENT THE TOTAL SCOPE OF THE DEMOLITION CONTRACT. THE INTENT OF THESE DRAWINGS IS TO ASSIST THE GENERAL CONTRACTOR WITH ESTIMATION ONLY WITHOUT LIMITING DEFINITION OF SCOPE. THE INTENT OF DEMOLITION IS TO COMPLETELY REMOVE ALL ITEMS, EXCEPT AS NOTED OTHERWISE, WITHIN THE CONTRACT AREA TO THE ORIGINAL STRUCTURE AS NECESSARY TO PREPARE FOR NEW CONSTRUCTION WORK SHOWN IN THESE CONTRACT DOCUMENTS.

AutoCAD SHX Text 11.

AutoCAD SHX Text 10.

AutoCAD SHX Text 9.

AutoCAD SHX Text 6.

AutoCAD SHX Text 5.

AutoCAD SHX Text 4.

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text PATCH FLOORS IN AREAS OF DEMOLITION TO ACHIEVE A SMOOTH SURFACE FOR NEW FLOORING AND WALLS AS REQUIRED TO RECEIVE NEW FLOOR FINISHES INDICATED ON THE ROOM FINISH SCHEDULE. FLOOR DEVIATIONS OVER 1/8" PER 5 FEET SHALL BE GROUND OUT OR FILLED TO ACHIEVE UNIFORM TRANSITION.

AutoCAD SHX Text 7.

AutoCAD SHX Text CONTRACTOR IS RECOMMENDED TO FIELD VERIFY ALL CONDITIONS PRIOR TO BIDDING TO DETERMINE THE TOTAL QUANTITIES AND SCOPE OF DEMOLITION THAT IS TO OCCUR. FIELD DIMENSIONS SHALL OCCUR PRIOR TO SHOP DRAWINGS.

AutoCAD SHX Text 8.

AutoCAD SHX Text ALL MATERIALS REMOVED AND NOT REUSED SHALL BECOME PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE SPECIFICALLY DESIGNATED TO REMAIN THE PROPERTY OF THE OWNER. HOWEVER, THE OWNER RESERVES THE RIGHT TO ALL ITEMS BEING REMOVED PRIOR TO THE SCHEDULED TIME OF REMOVAL.

AutoCAD SHX Text 3.

AutoCAD SHX Text

%%UGENERAL DEMOLITION NOTES:

AutoCAD SHX Text NPS TO HAVE ALL EXISTING FURNITURE REMOVED FROM AREA HAVING DEMO WORK UNLESS NOTED OTHERWISE. COORDINATE EXTENTS WITH COR AND PARK STAFF PRIOR TO STARTING WORK. SOME ITEMS MAY NOT BE ABLE TO BE MOVED AND SHALL BE PROTECTED BY THE CONTRACTOR.

AutoCAD SHX Text CONTRACTOR SHALL HAUL ALL DEMOLITION DEBRIS COMPLETELY AWAY FROM THE SITE & DISPOSE OF PROPERLY.

AutoCAD SHX Text ALL EXISTING CONDITIONS/MATERIALS SHALL BE PROTECTED DURING RENOVATION TO PREVENT DAMAGE. ANY DAMAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

AutoCAD SHX Text ITEMS NOT IDENTIFIED FOR REMOVAL IN DOCUMENTS SHALL REMAIN AS EXISTING AND IN THE CONDITION THAT THEY ARE TO CURRENT DATE.

AutoCAD SHX Text 22.

AutoCAD SHX Text 21.

AutoCAD SHX Text 20.

AutoCAD SHX Text 19.

AutoCAD SHX Text 24.

AutoCAD SHX Text 25.

AutoCAD SHX Text CUT AND PATCH EXISTING AND NEW WORK AS REQUIRED AND AS IDENTIFIED IN DOCUMENTS. ITEMS TO BE SALVAGED ARE TO BE CUT CAREFULLY AND STORED TO AVOID DAMAGE.

AutoCAD SHX Text 26.

AutoCAD SHX Text ITEMS TO BE SALVAGED AND RE-USED SHALL BE STORED IN A MANNER TO AVOID DAMAGE TO THE MATERIALS AND THEIR FINISHES, INCLUDING METHOD OF STACKING, ENVIRONMENTAL CONDITIONS, ETC. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PROTECTION AND PROPER ENVIRONMENTAL CONDITIONS FOR STORAGE OF NEW MATERIALS

AutoCAD SHX Text 27.

AutoCAD SHX Text 28.

AutoCAD SHX Text

SEE DEMOLITION PLANS FOR SALVAGE ITEMS.

AutoCAD SHX Text 29.

AutoCAD SHX Text 30.

AutoCAD SHX Text 23.

AutoCAD SHX Text

SEE MECHANICAL/ELECTRICAL DRAWINGS FOR NEW PIPING AND ELECTRICAL WORK.

AutoCAD SHX Text 31.

AutoCAD SHX Text MAINTAIN A SECURE AND WEATHER-TIGHT BUILDING AT THE END OF EACH DAY AND PRIOR TO INCLIMATE WEATHER. CONTRACTOR IS LIABLE FOR DAMAGES RESULTING FROM NEGLIGENCE AND IMPROPER WEATHER-TIGHT MEASURES.

AutoCAD SHX Text COORDINATE ALL POWER AND UTILITY SHUT-OFFS DATES AND DOWN TIMES WITH C.O.R. AND PARK REPRESENTATIVE. PROVIDE A MINIMUM OF A WEEK NOTICE PRIOR TO ANY DISTURBANCE IN FACILITIES WITH CONTINUED OCCUPANCY.

AutoCAD SHX Text 24.

AutoCAD SHX Text VERIFY MECHANICAL AND ELECTRICAL DRAWINGS FOR SCOPE AND INTERFACE. CONTRACTOR SHALL COORDINATE LOCATION FOR ALL MECHANICAL AND ELECTRICAL ITEMS WITH GENERAL CONSTRUCTION. REVIEW ANY DISCREPANCIES WITH THE CONTRACTING OFFICER PRIOR TO INSTALLATION AND/OR FABRICATION.

AutoCAD SHX Text

(LOOSE FILL OR BATT)

AutoCAD SHX Text

WOOD (DIMENSION)

AutoCAD SHX Text

WOOD (FINISH)

AutoCAD SHX Text

RIGID INSULATION

AutoCAD SHX Text

FLEXIBLE INSULATION

AutoCAD SHX Text

STEEL

AutoCAD SHX Text

CONCRETE BLOCK (PLAN)

AutoCAD SHX Text

CONCRETE BLOCK (SECTION)

AutoCAD SHX Text

CONCRETE (LARGE SCALE)

AutoCAD SHX Text

CONCRETE (SMALL SCALE)

AutoCAD SHX Text

BRICK

AutoCAD SHX Text

GRANULAR FILL

AutoCAD SHX Text

EARTH

AutoCAD SHX Text %%uARCHITECTURAL SYMBOLS

AutoCAD SHX Text

DIRECTION OF VIEW

AutoCAD SHX Text

DOOR NUMBER

AutoCAD SHX Text

EQUIPMENT NUMBER

AutoCAD SHX Text

WINDOW DESIGNATION

AutoCAD SHX Text

TOILET ACCESSORY

AutoCAD SHX Text

FLAG NOTE

AutoCAD SHX Text

ROOM NUMBER

AutoCAD SHX Text

COLUMN

AutoCAD SHX Text

DETAIL PHOTO <SEE 2/AD1.0>

AutoCAD SHX Text

WALL TYPE

AutoCAD SHX Text

WINDOW DESIGNATION

AutoCAD SHX Text

AutoCAD SHX Text

DOOR NUMBER

AutoCAD SHX Text

AutoCAD SHX Text

FLAG NOTE DESIGNATION

AutoCAD SHX Text

EQUIPMENT NUMBER

AutoCAD SHX Text

TA-

AutoCAD SHX Text

XX

AutoCAD SHX Text

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

TOILET ACCESSORY

AutoCAD SHX Text

COLUMN LINE

AutoCAD SHX Text

LETTER / NUMBER INDICATES

AutoCAD SHX Text

DETAIL NUMBER

AutoCAD SHX Text

BUILDING CROSS SECTION

AutoCAD SHX Text

MULTIPLE ROOM ELEVATIONS

AutoCAD SHX Text

INDIVIDUAL ELEVATION

AutoCAD SHX Text

PLAN DETAIL

AutoCAD SHX Text

WALL SECTION/ DETAIL

AutoCAD SHX Text

INDICATES DIRECTION OF VIEW

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

DETAIL NUMBER

AutoCAD SHX Text

DIRECTION OF VIEW

AutoCAD SHX Text

ELEVATION LETTER

AutoCAD SHX Text

DETAIL NUMBER

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

SECTION/DETAIL NUMBER

AutoCAD SHX Text

CROSS SECTION NUMBER

AutoCAD SHX Text

INDICATES DIRECTION OF VIEW

AutoCAD SHX Text

XX/XX-X

AutoCAD SHX Text

XX/XX-X

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text %%uREFERENCE LEGEND

AutoCAD SHX Text

WOOD STUD PARTITION (PLAN VIEW)

AutoCAD SHX Text

METAL STUD PARTITION (PLAN VIEW)

AutoCAD SHX Text

ACOUSTIC TILE

AutoCAD SHX Text

GYPSUM BOARD

AutoCAD SHX Text

PARTICLE BOARD

AutoCAD SHX Text

PLYWOOD

AutoCAD SHX Text

NUMBER AND LETTER INDICATES PARTITION OR WALL TYPE

AutoCAD SHX Text 1.1A

AutoCAD SHX Text

XX

AutoCAD SHX Text X-X

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

XX

AutoCAD SHX Text X-X

AutoCAD SHX Text

XX

AutoCAD SHX Text X-X

AutoCAD SHX Text

DIRECTION OF VIEW

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

DETAIL NUMBER

AutoCAD SHX Text

AutoCAD SHX Text

FACE OF FOUNDATION WALL

AutoCAD SHX Text

FACE OF FOUNDATION WALL LINE

AutoCAD SHX Text

LETTER / NUMBER INDICATES

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text X

X

CURATOR

OFFICE

UTILITY

RESEARCH

OFFICE

UNISEX

STAGING

AREA

COLLECTIONS

STORAGE

VAULT

LOADING

DOCK

1. REMOVE AND LEGALLY DISPOSE OF ALL ITEMS EXCEPT ITEMS INDICATED TO BE REINSTALLED, SALVAGED, OR TO REMAIN THE GOVERNMENT'S PROPERTY.

2. EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND

SOILING DURING SELECTIVE DEMOLITION.

3. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE SALVAGED OR OTHERWISE INDICATED TO

REMAIN THE GOVERNMENT'S PROPERTY, DEMOLISHED MATERIALS SHALL BECOME THE

CONTRACTOR'S PROPERTY AND SHALL BE REMOVED FROM THE SITE WITH FURTHER DISPOSITION

AT THE CONTRACTOR'S OPTION.

4. IDENTIFY AND ACCURATELY LOCATE CAPPED UTILITIES AND OTHER SUBSURFACE STRUCTURAL, ELECTRICAL, OR MECHANICAL CONDITIONS.

5. REGULATORY REQUIREMENTS: COMPLY WITH GOVERNMENTAL AGENCIES BEFORE STARTING

SELECTIVE DEMOLITION. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES

HAVING JURISDICTION

6. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON SITE WILL NOT BE PERMITTED.

7. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST

DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS.

8. UTILITY REQUIREMENTS: LOCATE, IDENTIFY, SHUT OFF, DISCONNECT, AND SEAL OR CAP OFF

INDICATED UTILITY SERVICES SERVING BUILDINGS TO BE SELECTIVELY DEMOLISHED.

9. WHERE UTILITY SERVICES ARE REQUIRED TO BE REMOVED, RELOCATED, OR ABANDONED, PROVIDE

BYPASS CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE TO OTHER PARTS OF THE PARK

BEFORE PROCEEDING WITH SELECTIVE DEMOLITION.

10. DRAIN, PURGE, OR OTHERWISE REMOVE, COLLECT, AND DISPOSE OF CHEMICALS, GASES,

EXPLOSIVES, ACIDS, FLAMMABLES, OR OTHER DANGEROUS MATERIALS BEFORE PROCEEDING WITH

SELECTIVE DEMOLITION OPERATIONS.

11. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED FACILITIES. INSIDE, PROTECT ADJACENT MATERIALS FROM DAMAGE FROM DEMOLITION ACTIVITIES. ADVISE COR IF OWNER ITEMS

POSE CONCERN , YET CONTRACTOR SHALL PROTECT OWNER MATERIALS.

12. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT

SURFACES AND AREAS.

13. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE

START OF SELECTIVE DEMOLITION.

14. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW

CONSTRUCTION AND AS INDICATED.

15. PROMPTLY PATCH AND REPAIR HOLES AND DAMAGED SURFACES CAUSED TO ADJACENT

CONSTRUCTION BY SELECTIVE DEMOLITION OPERATIONS, WHERE REPAIRS TO EXISTING SURFACES

ARE REQUIRED, PATCH TO PRODUCE SURFACES SUITABLE FOR NEW MATERIALS AND FINISH.

16. RESTORE EXPOSED FINISHES OF PATCHED AREAS AND EXTEND FINISH RESTORATION INTO

ADJOINING CONSTRUCTION TO REMAIN IN A MANNER THAT ELIMINATES EVIDENCE OF PATCHING

AND REPAIRING.

17. ALL DEMOLITION WORK TO BE COORDINATED WITH NEW WORK. IF UNDOCUMENTED CONDITIONS EXIST THAT ARE AFFECTED BY NOTED DEMOLITION, CONTACT THE CONTRACTING OFFICER BEFORE

PROCEEDING.

SALVAGE FLAG NOTES:

DEMOLITION FLAG NOTES:

ARCHITECTURAL FLAG NOTES:

N

AutoCAD SHX Text

AD1.0

AutoCAD SHX Text

AMM

AutoCAD SHX Text

ARCHITECTURAL

AutoCAD SHX Text

DEMOLITION PLAN

AutoCAD SHX Text

PHOTOS

AutoCAD SHX Text

AutoCAD SHX Text 4 0 4 8

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text D1

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NO.

AutoCAD SHX Text

PMIS

AutoCAD SHX Text

OF

AutoCAD SHX Text Date

AutoCAD SHX Text Mark

AutoCAD SHX Text Sheet

AutoCAD SHX Text

REVISION

AutoCAD SHX Text Initial

AutoCAD SHX Text 05-03-2023

AutoCAD SHX Text

AMM/KES

AutoCAD SHX Text

BADLANDS NATIONAL PARK INTERIOR, SD

AutoCAD SHX Text

AutoCAD SHX Text 137 80111

AutoCAD SHX Text

AutoCAD SHX Text 237 636 --

AutoCAD SHX Text

AMM/KES

AutoCAD SHX Text D1

AutoCAD SHX Text D1

AutoCAD SHX Text A

AutoCAD SHX Text SALVAGE AND PROTECT IN PLACE EXISTING FRAME. SEE BUILD BACK PLAN FOR REPAIR / PREP NOTES.

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text D2

AutoCAD SHX Text D2

AutoCAD SHX Text

PROTECT EXISTING FINISHES TO REMAIN

AutoCAD SHX Text

AutoCAD SHX Text

(APPLIES TO THIS SHEET ONLY)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FIRST FLOOR DEMOLITION PLAN

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AD1.0

AutoCAD SHX Text 2B

AutoCAD SHX Text 2A

AutoCAD SHX Text 2C

AutoCAD SHX Text 2D

AutoCAD SHX Text

PHOTOS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AD1.0

AutoCAD SHX Text 2G

AutoCAD SHX Text 2E

AutoCAD SHX Text

2A INTERIOR DOOR 01A

AutoCAD SHX Text

2B EXTERIOR DOOR 01A

AutoCAD SHX Text

2C STORAGE SIDE DOOR 01B

AutoCAD SHX Text

2D STAGING SIDE DOOR 01B

AutoCAD SHX Text

2E LOADING DOCK AT OVERHEAD DOOR

AutoCAD SHX Text

2F STAGING SIDE AT OVERHEAD DOOR

AutoCAD SHX Text DOOR REPLACEMENT SHALL OCCUR AS TO MAINTAIN COLLECTIONS STORAGE VAULT SECURITY. SAME DAY REMOVAL/REPLACEMENT WITH SECURITY SYSTEM IN PLACE TO PROVIDE A SECURED SPACE AS DETERMINED BY THE COR AND PARK CHIEF OFFICER. COMPLETE WORK MAY OCCUR OVER ADDITIONAL DAYS TO FINALIZE COMPLETE INSTALLATION AFTER MINIMUM OF LOCKING, EXITING AND SECURITY DOOR POSITION SWITCHES ARE INTACT AND OPERATIONAL AT END OF EACH DAY.

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

SALVAGE AND PROTECT DOOR POSITION SWITCHES FOR RE-INSTALLATION.

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PHOTO REFERENCE TYP., SEE 2/AD1.0

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TYP.

AutoCAD SHX Text

2G STAGING SIDE AT SIDE OVERHEAD DOOR

AutoCAD SHX Text 2F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE TEMPORARY DUST ENCLOSURE THROUGH THE ENTIRE DOOR REPLACEMENT / WORK PROCESS (ZIPWALL ZDS, TRIMACO E-Z UP DUST CONTAINMENT OR EQUAL. SHALL BE CLEAR FOR SECURITY PURPOSES, 4 MIL. MIN., FLAME RETARDANT WITH BUILT-IN ZIPPER DOOR ACCESS)

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

@ AT ROOF UNITAT ROOF UNIT

A. EXISTING CONDITIONS ARE BASED ON DRAWINGS PROVIDED BY

THE OWNER AND LIMITED FIELD VERIFICATION. THE

CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS

AND DIMENSIONS AND NOTIFY THE ARCHITECT/ENGINEER OF

ANY DISCREPANCIES OR VARIATIONS FROM THOSE SHOWN ON

THE DRAWINGS. THE CONTRACTOR SHALL ADJUST TO ACTUAL

FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE

OWNER.

B. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING ENTIRE

SET OF DOCUMENTS TO DETERMINE THEIR FULL SCOPE OF

WORK. CONTRACTOR SHALL NOT BE ALLOWED EXTRA COSTS

DUE TO FAILURE TO REVIEW ENTIRE SET OF DOCUMENTS.

C. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR WORK

AND BE RESPONSIBLE FOR SAME. CONTRACTOR SHALL

ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL

EXPENSE TO OWNER. COORDINATE THE WORK AND SHOP

DRAWINGS WITH ALL OTHER TRADES AFFECTED.

D. SCREENED HALF-TONE LINES INDICATE EXISTING

CONSTRUCTION TO REMAIN. FULL-TONE LINES INDICATED NEW

OR RELOCATED CONSTRUCTION.

E. CONTRACTOR SHALL COORDINATE THE ROUTING OF ALL

DUCTWORK WITH STRUCTURE, CEILING, LIGHTING, AND PIPING.

F. MAINTAIN MANUFACTURER'S REQUIRED CLEARANCE AROUND

ALL EQUIPMENT TO ALLOW FOR MAINTENANCE ACCESS.

G. ALL PIPING IN CONCEALED LOCATIONS SHALL BE ROUTED AT

RIGHT ANGLES AND PARALLEL TO BUILDING WALLS UNLESS

OTHERWISE INDICATED.

H. DO NOT ROUTE DUCTWORK OR PIPING ABOVE ELECTRICAL

PANELS. MAINTAIN ALL CODE REQUIRED CLEARANCES.

I. IN THE EVENT THE CONTRACTOR ENCOUNTERS ON THE SITE,

MATERIAL REASONABLY BELIEVED TO BE ASBESTOS, LEAD-

BASED PAINT, OR ANY OTHER HAZARDOUS MATERIAL WHICH

HAS NOT BEEN RENDERED HARMLESS, THE CONTRACTOR

SHALL IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND

REPORT THE CONDITION TO THE OWNER AND ARCHITECT IN

WRITING. THE WORK IN THE AFFECTED AREA SHALL NOT

THEREAFTER BE RESUMED EXCEPT BY WRITTEN AGREEMENT

OF THE OWNER AND CONTRACTOR.

J. ALL RUNOUTS TO AIR TERMINALS SHALL MATCH INLET SIZE

UNLESS OTHERWISE NOTED.

K. ANY UTILITY OR SYSTEM DISRUPTIONS OR OUTAGES DURING

CONSTRUCTION SHALL BE COORDINATED WITH THE OWNER

AND GENERAL CONTRACTOR.

ALL WORK TO BE COORDINATED WITH PARK STAFF TO ENSURE ALL

COLLECTIONS MATERIALS AND EQUIPMENT ARE PROPERLY PROTECTED DURING

THE FULL CONSTRUCITON TIMELINE.

CONTRACTOR SHALL KEEP EXISTING EQUIPMENT OPERATIONAL UNTIL NEW

EQUIPMENT IS ON SITE AND READY FOR INSTALLATION AND STARTUP.

DURING DOWNTIME FOR EQUIPMENT CHANGEOVER THE FOLLOWING SPACE

CONDITIONS ARE TO BE MAINTAINED:

TEMPERATURE: 50-75°F AND MAY NOT BE OUT OF RANGE FOR LONGER THAN

48 HOURS.

HUMIDITY: 40-60%RH MUST BE MAINTAINED FOR THE EXTENT OF DOWNTIME.

CONTRACTOR SHALL MONITOR AND KEEP LOG OF SPACE TEMPERATURE AND

HUMIDITY DURING DOWNTIME TO ENSURE SPACES ARE KEPT IN ACCEPTABLE

RANGES. DATA LOGS HALL BE KEPT FOR 48 HOURS PRIOR TO CHANGEOVER,

DURING WORK, AND THROUGH STARTUP OF NEW UNITS UNTIL SPACE

CONDITIONS HAVE NORMALIZED. DATA LOGGING SHALL PROVIDE ALARM IF

ALLOWABLE TOLERANCES ARE EXCEEDED DURING THIS PERIOD.

METHOD(S) FOR KEEPING SPACES WITHIN ACCEPTABLE TOLERANCES IS AT THE

CONTRACTOS DISCRETION BUT MAY INCLUDE ONE OR COMBINATION OF THE

FOLLOWING:

1) TEMPORANY COOLING UNITS

2) TEMPORARY HEAITNG UNITS

3) TEMPORARY DEHUMIDIFIER

4) TEMPORARY HUMIDIFIER

5) COORDINATE DOWNTIME WITH FAVORABLE WEATHER CONDITIONS

COMPLETION AND STARTUP OF EQUIPMENT REPLACEMENT SHALL NOT OCCUR

LEADING INTO A WEEKWND (SATURDAY AND SUNDAY) TO ENSURE MONITORING

OF NEW SYSTEM OPERATION IS AVAILABLE.

A. THE DEMOLITION PLANS WERE PRODUCED BY DUPLICATING THE

ORIGINAL DRAWINGS PROVIDED BY THE OWNER AND LIMITED

FIELD VERIFICATION. DIMENSIONS AND EXISTING CONDITIONS

ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY EXISTING

CONDITIONS. ITEMS WHICH ARE INTENDED TO BE REMOVED,

RELOCATED, OR SALVAGED ARE SHOWN AS SOLID, FULL-TONE

LINES. ALL OTHER ITEMS ARE INTENDED TO REMAIN IN PLACE

AND ARE SHOWN AS HALF-TONE.

B. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE ITEMS

LISTED BELOW OR HERE-IN. THE CONTRACTOR SHALL

COORDINATE ALL REQUIRED RENOVATION AND NEW

CONSTRUCTION WITH THE EXISTING BUILDING TO IDENTIFY THE

TOTAL EXTENT OF THE DEMOLITION REQUIRED AND AS LISTED

BELOW.

C. THE REMOVAL OF FIRE PROTECTION, HVAC, AND PLUMBING

EQUIPMENT FROM FINISHED AREAS AND THROUGH WEATHER

BARRIERS SHALL BE COORDINATED WITH ARCHITECTURAL PLANS

AND DETAILS AS WELL AS NOTES ON THE MECHANICAL DRAWING

TO ENSURE PROPER PATCHING AND REPAIR IS MADE TO THE

BUILDING.

D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION

AND REMOVAL OF ALL EXISTING COMPONENTS, MATERIALS,

EQUIPMENT, AND APPURTENANCES TO BUILD, ERECT, INSTALL, OR

ACCOMMODATE ALL NEW CONSTRUCTION WITH THE OWNER

HAVING FIRST RIGHT OF REFUSAL ON ALL ITEMS.

E. ITEMS NOTED TO BE REMOVED AND SALVAGED OR REINSTALLED

SHALL BE CAREFULLY REMOVED BY THE CONTRACTOR WITHOUT

DAMAGE AND STORED OR REINSTALLED ON THE SITE AS

DIRECTED. REMOVED OR SALVAGED ITEMS SHALL REMAIN THE

PROPERTY OF THE OWNER.

F. COORDINATE THE DISCONNECTION OF ELECTRICAL MOTORS AND

CONTROLS WITH ELECTRICAL CONTRACTOR PRIOR TO

MECHANICAL REMOVALS.

G. IN THE EVENT THE CONTRACTOR ENCOUNTERS ON THE SITE,

MATERIAL REASONABLY BELIEVED TO BE ASBESTOS, LEAD-BASED

PAINT, OR ANY OTHER HAZARDOUS MATERIAL WHICH HAS NOT

BEEN RENDERED HARMLESS, THE CONTRACTOR SHALL

IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND REPORT

THE CONDITION TO THE OWNER AND ARCHITECT IN WRITING. THE

WORK IN THE AFFECTED AREA SHALL NOT THEREAFTER BE

RESUMED EXCEPT BY WRITTEN AGREEMENT OF THE OWNER AND

ARCHITECT.

H. ANY UTILITY OR SYSTEMS DISRUPTION OR OUTAGES DURING

DEMOLITION SHALL BE COORDINATED WITH THE OWNER AND

GENERAL CONTRACTOR.

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M 00

MECHANICAL INFO SHEET

07310035- 5- M 00 MECHANICAL INFO SHEET

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD

SYMBOL LEGEND

VOLUME DAMPER

DEMO TO EXISTING CONNECTION

SPRINKLER DRAIN

FIRE SUPPRESSION PIPING

ISOLATION VALVE

TAMPER SWITCH

MANUAL BALANCING VALVE

FLOW SWITCH

FIRE DEPARTMENT CONNECTION

CONTROL VALVE (3 WAY)

CONTROL VALVE (2 WAY)

HOSE END DRAIN VALVE

PRESSURE REDUCING VALVE

AUTO FLOW CONTROL VALVE

CHECK VALVE

HVAC DUCTWORK AND SPECIALTIES

(CONT.)

MISCELLANEOUS SYMBOLS

RETURN DUCT DOWN

AIR TERMINAL (VERTICAL MOUNTING)

ROUND DUCT UP / DOUBLE LINE PIPE

ROUND DUCT DOWN / DOUBLE

LINE PIPE

RETURN DUCT UP

TURNING VANES

SUPPLY AND FRESH AIR DUCT DOWN

SUPPLY AND FRESH AIR DUCT UP

SIZE/TYPE

SIZE/TYPE

FLOW

FLOW

SIZE/TYPE

FLOW

SMOKE DAMPER

FIRE DAMPER-HORIZ FIRE SEPARATION

MOTORIZED DAMPER-OPPOSED BLADE

MOTORIZED DAMPER-PARALLEL BLADE

ROUND AIR TERMINAL

(HORIZONTAL MOUNTING)

GRAVITY DAMPER

(OR) SAFETY VALVE-STEAM

TEMP & PRESS RELIEF

FLOOR SINK

FLOOR DRAIN

GRADE CLEANOUT

PLUMBING VENT THRU ROOF

CLEANOUT / WALL CLEANOUT

THERMOSTATIC MIXING VALVE

M

M

MANHOLE

TRENCH DRAIN

OVERFLOW ROOF DRAIN

OXYGEN OUTLET

PIPE CAP

ELBOW UP

AIR OUTLET

TEE

ELBOW DOWN

VACUUM OUTLET

ROOF DRAIN

SIZE/TYPE

FLOW

HUMIDISTAT

THERMOSTAT

FLEXIBLE DUCT

S

H

T

TEMPERATURE SENSORUNION

TEE DOWN

STRAINER

EXPANSION JOINT

FLEXIBLE PIPE CONNECTION

AIR VENT

TEE UP

FIRE/SMOKE DAMPER

RECTANGULAR RETURN AIR TERMINAL

(HORIZONTAL MOUNTING)

RECTANGULAR SUPPLY AIR TERMINAL

(HORIZONTAL MOUNTING)

SOLENOID VALVE

F

D

TS

VALVES

FS

M

M

S

LPR

HPS

MPR

MPS

LPS

HVAC PIPING

GHWR

GHWS

HWR

HWS

PC

HPR

ES

BBD BOILER BLOW DOWN

EXHAUST STEAM

PUMPED CONDENSATE

HIGH PRESSURE RETURN

HIGH PRESSURE STEAM

MEDIUM PRESSURE RETURN

MEDIUM PRESSURE STEAM

LOW PRESSURE RETURN

LOW PRESSURE STEAM

GLYCOL HOT WATER RETURN

GLYCOL HOT WATER SUPPLY

HOT WATER RETURN

HOT WATER SUPPLY

FS-_

FD-_

CO

VTR

GCO

ORD-_

MH

X

A

V

RD-_

PIPING SPECIALTIES AND FITTINGS

WCO

FIRE PROTECTION

SIZE/TYPE

FLOW

RECTANGULAR EXHAUST AIR TERMINAL

(HORIZONTAL MOUNTING)

CWS

GCWS

CWR

CR

CS

RL

RDL

RS

GCWR GLYCOL CHILLED WATER RETURN

GLYCOL CHILLED WATER SUPPLY

REFRIGERANT LIQUID LINE

CHILLED WATER RETURN

CHILLED WATER SUPPLY

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

REFRIGERANT DISCHARGE

REFRIGERANT SUCTION LINE

HCWS

HCWR

HOT/CHILLED WATER SUPPLY

HOT/CHILLED WATER RETURN

DOMESTIC HOT WATER

RECIRCULATING (DHWR)

DOMESTIC COLD WATER (DCW)

DOMESTIC HOT WATER (DHW)

ST/OST

PLUMBING PIPING

ACID VENT

TW

AV

AW

W

DS

DSCW

TWR

DSHW

SANITARY VENT

BURIED EXTERIOR WATER

TEPID WATER RECIRCULATING

TEPID WATER

DISTILLED WATER

SOFTENED HOT WATER

SOFTENED COLD WATER

ACID WASTE

STORM DRAIN

SANITARY DRAIN (BELOW FLOOR)

SANITARY DRAIN (ABOVE FLOOR)

OXYGEN

VACUUM

OX

VAC

RO

A

REVERSE OSMOSIS WATER

COMPRESSED AIR

DEIONIZED WATERDI

AIR FLOW STATIONAFS

HPWR

HPWS

HEAT PUMP WATER RETURN

HEAT PUMP WATER SUPPLY

F

S

FS

NEW TO EXISTING CONNECTION

G NATURAL GAS

FOF

FOG

LPG

FOV

FOR

FOS

FUEL OIL RETURN

FUEL OIL SUPPLY

FUEL OIL GAGE

FUEL OIL FILL

FUEL OIL VENT

LIQUEFIED PETROLEUM GAS

CD CONDENSATE DRAIN

EXHAUST DUCT DOWN

EXHAUST DUCT UP

CO CARBON MONOXIDE SENSOR

CO2 CARBON DIOXIDE SENSOR

NO2 NITROGEN DIOXIDE SENSOR

SENSOR WITH GUARD'X'

DOUBLE - GRADE CLEANOUTDGCO

ST/OST STORM DRAIN (BELOW FLOOR)

WASTE AND ANESTHETIC

GAS DISPOSAL

NITROGEN

WAGD

N

MEDICAL AIRMA

PIPE GUIDE

HOSE BIBB

THERMOMETER

PIPE ANCHOR

HB

STEAM TRAP

RHY

WH

ROOF HYDRANT

WALL HYDRANT

PRESSURE GAUGE

EXISTINGDEMO

EXISTINGNEW

18 Ø

18x10

18/10

ROUND DUCT

FLAT OVAL DUCT-1ST FIG IS SIDE

SHOWN

RECT DUCT-1ST FIG IS SIDE SHOWN

ACOUSTICAL DUCT LINER

HVAC DUCTWORK AND SPECIALTIES

HIGH EFFICIENCY TAKEOFF

HIGH EFFICIENCY TAKOFF

WITH VOLUME DAMPER

NITROGEN OUTLET

MEDICAL AIR OUTLET

WASTE AND ANESTHETIC GAS

DISPOSAL OUTLET

N

MA

V

FLEXIBLE DUCTWORK CONNECTION

ABBREVIATIONS

NORTH

ARROW

MATCHLINE

AREA A

AREA B

EXISTING

COLUMN

NEW

COLUMN

X

X

X

XXXX

SIM/OPP

X

XXXX

XX-1

X

X

SECTION/

DETAIL

PLAN

DETAIL

REFERENCE

NOTE

REFERENCE

DEMOLITION

NOTE

EQUIPMENT

NUMBER

ROOM NAME

ROOM / SPACE

NUMBER

LETTER/NUMBER

INDICATES NEW

COLUMN LINE

LETTER/NUMBER

INDICATES EXISTING

COLUMN LINE

SECTION/DETAIL NUMBER

SHEET NUMBER

INDICATES DIRECTION OF VIEW

DETAIL NUMBER

SHEET NUMBER

REFERENCE

DESIGNATION

DEMOLITION

DESIGNATION

EQUIPMENT

NUMBER

ROOM NAME DESIGNATION

ROOM NUMBER DESIGNATION

REFERENCE LEGEND

NAME

ELEVATION

LEVEL

TITLE

MARKER

VIEW NAME

SCALE: 1/8" = 1'-0"

DRAWING/DETAIL NUMBER

LEVEL CALLOUT

DESIGNATION

ELEVATION

DESIGNATION

GRAPHIC AREA FOR

DRAWING

TITLE

SCALE OF THE DRAWING

XXX-1

PLUMBING

FIXTURES PLUMBING FIXTURE

DESIGNATION

X"PIPE

SIZE

PIPE SIZE (DIAMETER)

X"xX"

DUCT

SIZE

WIDTH x HEIGHT

X"/X" WIDTH / HEIGHT

X" DIAMETER

REF. DEMO NOTES ( ) XX REF. NOTES ( )

SEE INDIVIDUAL SHEETS FOR REFERENCE NOTES. SEE INDIVIDUAL SHEETS FOR REFERENCE NOTES.

GENERAL DEMOLITION NOTES GENERAL NOTES

MECHANICAL SHEET LIST

NORTH PLAN

NORTH

TRUE

NORTH

MAU MAKE-UP AIR UNIT

MAX MAXIMUM

MBH 1000 BTUH

MCA MINIMUM CIRCUIT AMPS

MD MOTORIZED DAMPER

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT

PROTECTION

MPR MEDIUM PRESSURE

RETURN

MPS MEDIUM PRESSURE STEAM

MS MOP SINK

N NITROGEN

NC NORMALLY CLOSED

NO NORMALLY OPEN

NPCW NONPOTABLE COLD WATER

NPHW NONPOTABLE HOT WATER

NPHWR NONPOTABLE HOT WATER

RECIRCULATING

OA OUTSIDE AIR

ORD OVERFLOW ROOF DRAIN

OX OXYGEN

P PUMP

PHC PREHEAT COIL

PIV POST INDICATING VALVE

PRV PRESSURE REGULATING VALVE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH,

GAUGE

PTAC PACKAGED TERMINAL AIR

CONDITIONER

RA RETURN AIR

RCP RADIANT CEILING PANEL

RD ROOF AREA DRAINS

RL REFRIGERANT DISCHARGE LINE

RF RETURN FAN

RH RELIEF HOOD

RHC REHEAT COIL

RL REFRIGERANT LIQUID LINE

RLA RELIEF AIR

RLF RELIEF FAN

RO REVERSE OSMOSIS WATER

RPM REVOLUTIONS PER MINUTE

RS REFRIGERANT SUCTION LINE

RTU ROOF TOP UNIT

RV RELIEF VALVE

S SINK

SA SUPPLY AIR

SAN SANITARY SEWER

SD SMOKE DAMPER

SF SUPPLY FAN

SFU SANITARY FIXTURE UNIT

SH SHOWER

SP STATIC PRESSURE

SSS SURGICAL SCRUB SINK

ST STORM WATER

TD TRENCH DRAIN

TMV THERMOSTATIC MIXING VALVE

TONS TONS OF REFRIGERATION

TSP TOTAL STATIC PRESSURE

T THERMOSTAT

UH UNIT HEATER

UR URINAL

V VENT

VAC VACUUM

VAV VARIABLE AIR VOLUME

VD VOLUME DAMPER

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VTR VENT THRU ROOF

WB WET BULB

WC WATER CLOSETS

WCO WALL CLEANOUT

WF WASH FOUNTAINS

WFU WATER FIXTURE UNITS

WH WALL HYDRANT

WPD WATER PRESSURE DROP

WS WATER SOFTENER

WSHP WATER SOURCE HEAT PUMP

WWHP WATER TO WATER HEAT PUMP

YH YARD HYDRANT

A COMPRESSED AIR

AC AIR COMPRESSOR

AD AIR DOOR

AFCV AUTO FLOW CONTROL VALVE

AHU AIR HANDLING UNIT

AMP AMPERE

APD AIR PRESSURE DROP

AS AIR SEPARATOR

AV ACID VENT

AW ACID WASTE

B BOILER

BC BLOWER COIL

BD BIDET

BFP BACKFLOW PREVENTER

BFV BUTTERFLY VALVE

BHP BRAKE HORSEPOWER

BLKG BLOCKING

BLV BALANCING VALVE

BT BATHTUB

BV BALL VALVE

BW BEDPAN WASHER

CH CHILLER

CC COOLING COIL

CD CONDENSATE DRAIN

CFM CUBIC FEET PER MINUTE

CUH CABINET HEATER

CI CAST IRON

CMU COMBINATION UNITS

CR CONDENSER WATER RETURN

CRAC COMPUTER ROOM AIR

CONDITIONER

CS CONDENSER WATER SUPPLY

CSS CLINICAL SERVICE SINKS

CT COOLING TOWER

CU CONDENSING UNIT - SPLIT SYSTEM

CWR CHILLED WATER RETURN

CWS CHILLED WATER SUPPLY

DB DRY-BULB TEMPERATURE

DCW DOMESTIC COLD WATER

DEG DEGREE

DF DRINKING FOUNTAIN

DGCO DOUBLE GRADE CLEANOUT

DH EMERGENCY DRENCH HOSES

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER

RECIRCULATING

DI DEIONIZED WATER

DOAS DEDICATED OUTDOOR AIR SYSTEM

DS DISTILLED WATER

DSA DUCT SOUND ATTENUATORS

DSCW DOMESTIC SOFT COLD WATER

DSHW DOMESTIC SOFT HOT WATER

DSHWR DOMESTIC SOFT HOT WATER

RECIRCULATING

DST DOMESTIC STORAGE TANK

DTW DOMESTIC TEPID WATER

DTWR DOMESTIC TEPID WATER

RECIRCULATING

EA. EACH

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EDH ELECTRIC DUCT HEATER

EEW EMERGENCY EYE WASH

EEWS EMERGENCY EYE

WASH/SHOWER

EF EXHAUST FAN

EFF EFFICIENCY

EFW EMERGENCY FACE WASH

EH EXHAUST HOOD

ERV ENERGY RECOVERY

VENTILATOR

ES EMERGENCY SHOWER

ESP EXTERNAL STATIC PRESSURE

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EWT ENTERING WATER

TEMPERATURE

ET EXPANSION TANK

F FIRE SUPPRESSION PIPING

F-_ FURNACE

FCO FLOOR CLEANOUT

FC FLUID COOLER

FCU FAN COIL UNIT

FD FIRE DAMPER

FLA FULL LOAD AMPS

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FOV FUEL OIL VENT

FPM FEET PER MINUTE

FPS FEET PER SECOND

FS FLOOR SINK

FSD FIRE/SMOKE DAMPER

FT FINNED TUBE

G GAS

GCWR GLYCOL CHILLED

WATER RETURN

GCWS GLYCOL CHILLED

WATER SUPPLY

GD GARBAGE DISPOSAL

GDH GAS DUCT HEATER

GHCR GLYCOL HOT/CHILLED

WATER RETURN

GHCS GLYCOL HOT/CHILLED

WATER SUPPLY

GHWR GLYCOL HOT WATER RETURN

GHWS GLYCOL HOT WATER SUPPLY

GI GREASE INTERCEPTOR

GPD GALLONS PER DAY

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GV GAS VENT

GWH GAS WATER HEATER

HB HOSE BIBB

HC HEATING COIL

HCR HOT/CHILLED WATER RETURN

HCS HOT/CHILLED WATER SUPPLY

ACC AIR COOLED CONDENSER

ACCU AIR COOLED CONDENSING UNIT

ASHP AIR SOURCE HEAT PUMP

ARU AIR ROTATION UNIT

OI OIL INTERCEPTOR

SOI SAND OIL INTERCEPTOR

DSS DUCTLESS SPLIT SYSTEM

SP SUMP PUMP

OST OVERFLOW STORM WATER

WMB WASHING MACHINE BOX

OB OUTLET BOX

RH ROOF HYDRANT

H HUMIDIFIER

DHWP DOMESTIC HOT WATER

RECIRCULATING PUMP

DWET DOMESTIC WATER EXPANSION

TANK

HP HORSEPOWER

HPR HIGH PRESSURE RETURN

HPS HIGH PRESURE STEAM

HRC HEAT RECOVERY COIL

HWR HOT WATER RETURN (HEATING)

HWS HOT WATER SUPPLY (HEATING)

HX HEAT EXCHANGER

HY HYDRANTS

HP-_ HEAT PUMP

HVLS HIGH VOLUME LOW SPEED

IH INTAKE HOOD

IRH INFRARED RADIANT HEATER

KH KITCHEN HOOD

KW KILOWATT

KWH KILOWATT HOURS

L LAVATORY

LAT LEAVING AIR TEMPERATURE

LPR LOW PRESSURE RETURN

LPG LIQUIFIED PETROLEUM GAS

LPS LOW PRESSURE STEAM

LRA LOCKED ROTOR AMPS

LS LAUNDRY SINK

LV LOUVER

LWT LEAVING WATER TEMPERATURE

PROJECT MECHANICAL REFERENCED DEMOLITION NOTES PROJECT MECHANICAL REFERENCED NOTES

M 00 MECHANICAL INFO SHEET

M 01 SHEET SPECIFICATIONS - MECHANICAL

M 02 SHEET SPECIFICATIONS - MECHANICAL

M 03 SHEET SPECIFICATIONS - MECHANICAL

M 04 SHEET SPECIFICATIONS - MECHANICAL

M001 DEMOLITION FLOOR PLAN - MECHANICAL

M101 FLOOR PLAN - MECHANICAL

M501 SCHEDULE - MECHANICAL

7 21

COLLECTIONS PROTECTION NOTES

DATE INITIAL

5/11/23

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M 01

SHEET SPECIFICATIONS -

MECHANICAL

07310035- 5- M 01 SHEET SPECIFICATIONS - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD 8 21

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ATP

JEK

05/03/2023

07310.035

M 02

SHEET SPECIFICATIONS -

MECHANICAL

07310035- 5- M 02 SHEET SPECIFICATIONS - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD 9 21

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M 03

SHEET SPECIFICATIONS -

MECHANICAL

07310035- 5- M 03 SHEET SPECIFICATIONS - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD 10 21

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M 04

SHEET SPECIFICATIONS -

MECHANICAL

07310035- 5- M 04 SHEET SPECIFICATIONS - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD 11 21

A

01B

CURATOR

OFFICE

UTILITY

RESEARCH OFFICE

UNISEX

STAGING AREA

COLLECTIONS STORAGE VAULT

LOADING DOCK

T

5 (TYP)

M501

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M001

DEMOLITION FLOOR PLAN

- MECHANICAL

07310035- 5- M001 DEMOLITION FLOOR PLAN - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD

REF. DEMO NOTES ( ):X

1 DEMOLISH EXISTING RTU. ROOF CURB TO REMAIN FOR NEW UNIT.

2 DEMOLISH INDOOR AIR HANDLER. REMOVE REFRIGERANT PIPING OUT TO

CONDENSING UNIT AND DUCTWORK BACK TO DROP AT ELBOWS.

3 DISCONNECT DOMESTIC WATER CONNECTION TO AHU HUMIDIFIER AND

PROTECT FOR CONNECTION TO NEW UNIT.

4 DEMOLISH EXISTING CONDENSING UNIT. EQUIPMENT PAD TO REMAIN

FOR NEW UNIT.

5 REMOVE EXISTING ROUND DUCT DROP AND PREPARE DUCT FOR NEW

GRILLE CONNECTION.

SCALE: 1/4" = 1'-0"

FIRST FLOOR PLAN - DEMO HVAC

NORTH

12 21

A

01B

CURATOR

OFFICE

UTILITY

RESEARCH OFFICE

UNISEX

STAGING AREA

COLLECTIONS STORAGE VAULT

LOADING DOCK

H S

T H

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

8x6 S-1

8x6 S-1

8 Ø

AHU-1

ACCU-1

H-1

12x8 S-1

12x8 S-1

12x8 S-1

12x8 S-1

12x8 S-1

10x6 S-1

10x6 S-1

10x6 S-1

10x6 S-1

10x6 S-1

10x6 S-1

RTU-1

5(TYP)

10 Ø

2"

1/2"

S A

N D

C W

R S

/L 10

(ON ROOF)

M501

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M101

FLOOR PLAN -

MECHANICAL

07310035- 5- M101 FLOOR PLAN - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD

REF. NOTES ( ):X

1 INSTALL SUPPLY DUCT IN LOADING DOCK AREA TIGHT TO THE BOTTOM OF

STRUCTURE.

2 ARCHIVE TEMPERATURE SENSOR AND HUMIDISTAT TO BE PENDANT

MOUNTED AT 8'-9" A.F.F. SETPOINTS ADJUSTED THROUGH AHU

INTERFACE.

3 UNIT TO HAVE BOTTOM PIPING CONNECTIONS. EXTEND EXISTING

DOMESTIC COLD WATER SUPPLY TO NEW UNIT HUMIDIFIER CONNECTION.

PIPE CONDENSATE DRAIN TO FLOOR DRAIN IN MECHANICAL ROOM.

4 HUMIDIFIER TO BE LOCATED HIGH ON WALL TO PROVIDE CLEARANCE FOR

REFRIGERATORS AND FREEZERS BELOW. PROVIDE DRAIN PAN BELOW

UNIT WITH WATER LEVEL SENSOR. SENSOR TO SHUT DOWN HUMIDIFIER

UPON DETECTION OF WATER.

5 SUPPLY GRILLE TAP ON BOTTOM SIDE OF SUPPLY DUCT. PROVIDE

BALANCING DAMPER IN TAP.

6 1/2" DCW SUPPLY TO HUMIDIFIER TO TAP OFF OF MAIN IN MECHANICAL

ROOM. PROVIDE ISOLATION VALVE IN NEW BRANCH LINE.

7 2" HUMIDIFIER DRAIN TO DRAIN TO FLOOR DRAIN IN MECHANICAL ROOM.

8 2" HUMIDIFIER DRAIN TO BE TYPE L COPPER AND BE INSULATED WITH

1-1/2" FIBERGLASS INSULATION.

9 CONTRACTOR TO ADAPT SUPPLY AND RETURN DUCT DROP TO CONNECT

TO NEW RTU

10 SIZE AND INSTALL REFRIGERANT LINES BETWEEN AHU AND ACCU PER

MANUFACTURER REQUIREMENTS.

11 ACCU-1 TO BE INSTALLED ON EXISTING CONCRETE PAD. INCREASE PAD

SIZE AS NECESSARY TO ACCOMMODATE NEW UNIT DIMENSIONS.

12 NEW RTU TO BE LOCATED ON EXISTING ROOF CURB. PROVIDE CURB

ADAPTER AS NECESSARY FOR NEW RTU.

13 10Ø DUCT TURNED UP ON BOTH ENDS WITH MESH SCREEN AT OPENINGS.

DUCT TO BE INSTALLED AS HIGH AS POSSIBLE IN LOADING AREA TO

PRESERVE FLOOR AIR BELOW.

14 PENETRATIONS AT 9'-6" TO CENTER OF DUCT THROUGH EXISTING

PRECAST WALL TO BE CORE DRILLED AND CAULKED AROUND THE FULL

PERIMETER OF DUCT. CONTRACTOR TO LOCATE REBAR IN EXISTING

WALL AND COORDINATE LOCATION TO ONLY CUT A SINGLE BAR IN EITHER

DIRECTION. COORDINATE WITH ELECTRICAL CONTRACTOR TO RELOCATE

CONDUIT AND J-BOXES AS NECESSARY TO MAKE ROOM FOR

PENETRATION.

15 TRAP AND PIPE CONDENSATE FROM RTU AND DRAIN TO ROOF SURFACE.

CONDENSATE PIPING DIAMETER TO MATCH EQUIPMENT CONNECTION

SIZE.

16 INSTALL WALL MOUNTED CONTROLS AT 48" A.F.F.

SCALE: 1/4" = 1'-0"

FIRST FLOOR PLAN - HVAC

NORTH

STAGING AREA

65-70°F

55% RH +/- 5%RH (MAX RANGE 50-60% RH)

COLLECTIONS VAULT

65°F +/- 5°F (MAX RANGE 60-70°F)

50% RH +/- 5%RH (MAX RANGE 45-55%)

SYSTEM OPERATING SETPOINTS

13 21

TOTAL

HEIGHT

OF TRAP

TO FLOOR DRAIN

TOTAL HEIGHT OF TRAP:

X + H + (1 1/2 x PIPE DIAMETER)

H = AT LEAST 1 INCH PLUS

CASING STATIC PRESSURE

X = 1/2 "H"

COIL CONDENSATE

DRAIN PAN

SLOPE DOWN

X

H

CLEAN OUT

HOUSEKEEPING PAD,

HEIGHT IS BASED ON

TRAP HEIGHT

FIRST FLOOR

100' - 0"

8" SUPPLY DUCT

10" RETURN DUCT

EXISTING OVERHEAD DOOR

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

237636

80111

C U s e rs \a p u llm a n n

\D o c u m e n ts \0

M

E C

H

R

B A

D L a p u llm a n n

L T

M M

V .r v t

ARP

ARP

JEK

05/03/2023

07310.035

M501

SCHEDULE - MECHANICAL

07310035- 5- M501 SCHEDULE - MECHANICAL

COLLECTIONS STORAGE BUILDING IMPROVEMENTS

BADLANDS NATIONAL PARK

INTERIOR, SD

6. PROVIDE WITH RETURN PLENUM SMOKE DETECTOR.

5. PROVIDE WITH MANUFACTURER STANDARD FLOOR STAND

4. PROVIDE WITH UPFLOW CABINET WITH TOP DUCTED SUPPLY AND BACK DUCTED RETURN CONNECTIONS.

3. PROVIDE WITH ELECTRODE CANISTER STEAM HUMIDIFIER.

2. PROVIDE WITH ELECTRIC HEAT MODULE

NOTES: 1. PROVIDE WITH MODULATING DIGITAL SCROLL COMPRESSOR IN AIR HANDLER AND HOT GAS REHEAT.

AHU-1 UTILITY - 03 ARCHIVE VERTICAL 2800 0.5 62.7 60 10 34.1 SCR 10 230 1 60 62.3 70 ABOVE AIR MCE018S1MGEOHEC00UFRB1S6 1-6

CFM

EXT SP IN

WG

TOTAL

(MBH)

SENSIBLE

(MBH)

ELECTRIC

HTG. (KW)

ELECTRIC

HTG. (MBH)

ELECTRIC

HTG.

STAGES STEAM LB/HR VOLTS PH HZ MCA MOCPMARK LOCATION SERVES TYPE

FAN DATA COOLING DATA HEATING DATA HUMIDIFIER DATA ELECTRICAL DATA

MANUFACTURER AND MODEL NUMBER REMARKS

AIR HANDLING UNIT SCHEDULE

ACCU-1 GRADE AHU-1 R410A 60 95 230 1 60 2.5 15 ABOVE AIR XP1018S1AAVF

VOLTS PH HZ MCA MOCPMARK LOCATION SERVES

REFER

TYPE

MIN CAP

MBH

AMBIENT

TEMP (°F)

CONDENSER DATA

MANUFACTURER AND MODEL

NUMBER REMARKS

AIR COOLED CONDENSING UNIT SCHEDULE

NOTES: 1. PROVIDE WITH BLOWER PACK FOR DIRECT ROOM HUMIDIFICATION AND STANDALONE HUMIDISTAT AND CONTROLS.

H-1 STAGING AREA - 06 RTU-1 ROOM DIRECT 11.4 3.7 240 1 60 16.1 25 CONDAIR RS 010 1

KW VOLTS PH HZ MCA MOCPMARK LOCATION SERVES TYPE

HUMIDIFICATION

CAPACITY (LBS/HR)

ELECTRICAL DATA

MANUFACTURER AND

MODEL NUMBER REMARKS

ELECTRIC HUMIDIFIER SCHEDULE

6. PROVIDE WITH MANUFACTURER STANDARD THERMOSTAT.

5. PROVIDE WITH HINGED ACCESS PANELS.

4. PROVIDE WITH NON-FUSED DISCONNECT, THRU-THE BASE CONNECTIONS, PHASE MONITOR, AND NON-POWERED CONVENIENCE OUTLET

3. PROVIDE WITH CONDENSER COIL HAIL GUARDS.

2. PROVIDE WITH RETURN PLENUM SMOKE DETECTOR.

NOTES: 1. PROVIDE WITH TRANSITION ROOF CURB AS NECESSARY TO USE EXISTING ROOF PENETRATION.

RTU-1 1325 100 0.5 36.78 29.05 2 12.6/17.0 36 3.6/8.2 15 SCR 230 1 104 110 595 DAIKIN DRH0361D015C 1-6

TOTAL

(MBH)

SENSIBLE

(MBH)

COMPRESSOR

STAGES

EFFICIENCY

(EER/SEER)

CAPACITY @47°F

(MBH)

EFFICIENCY @47°F

(COP/HSPF)

ELECTRIC

(KW)

ELECTRIC

HEAT

STAGES VOLTS PH

MIN CIRC

AMPS

MAX FUSE

AMPSMARK

SUPPLY

AIRFLOW

(CFM)

MIN OA

(CFM) ESP (IN WG)

COOLING HEATING ELECTRICAL DATA

WEIGHT

(LBS)

MANUFACTURER AND

MODEL NUMBER REMARKS

HEAT PUMP ROOF TOP UNIT SCHEDULE

NOTES: 1. PROVIDE DOUBLE DFLECTION GRILLE WITH OPPOSED BLADE DAMPER.

S-1 SUPPLY LOUVERED SEE PLANS SEE PLANS WHITE 0.1 25 300RL 1

MARK SERVES TYPE

FACE SIZE

(IN.)

NECK SIZE

(IN.) FINISH

MAX PD (IN

WG)

MAX NC AT

PD SHOWN

TITUS MODEL

NUMBER REMARKS

DIFFUSER, REGISTER AND GRILLE SCHEDULE

SCALE: NOT TO SCALE

CONDENSATE DRAIN TRAP NEGATIVE STATIC PRESSURE

14 21

SCALE: 1/4" = 1'-0"

ELEVATION AT LOADING DOCK

SURFACE MOUNTED CONDUIT

ON STAGING AREA SIDE OF

WALL. COORDINATE WITH

ELECTRICAL CONTRACTOR FOR

RELOCATION AS NECESSARY

FOR NEW PENETRATION.

SURFACE MOUNTED CONDUIT

ON LOADING DOCK SIDE OF

WALL. COORDINATE WITH

ELECTRICAL CONTRACTOR FOR

RELOCATION AS NECESSARY

FOR NEW PENETRATION.

A. SEE ARCHITECTURAL SHEETS FOR EXACT AREAS AND WALLS

AFFECTED BY THE DEMOLITION AND REMODEL.

B. DEMOLITION SHOWN IS AS REQUIRED FOR THE COMPLETE PROJECT.

COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES.

PROVIDE TEMPORARY POWER AND LIGHTS AS REQUIRED TO ALLOW

THE WORK OF OTHER TRADES TO PROCEED OR AS REQUIRED TO

ALLOW THE OWNER TO OCCUPY THE SPACE.

C. ALL OF THE EQUIPMENT AND DEVICES SHOWN ON THIS DRAWING ARE

EXISTING. THE LOCATIONS OF THE EQUIPMENT AND DEVICES WERE

OBTAINED FROM EXISTING DRAWING AND FIELD INVESTIGATION. THE

LOCATIONS OF THE EXISTING EQUIPMENT AND DEVICES ARE SHOWN

FOR THE CONVENIENCE OF THE CONTRACTOR. ACCURACY OF THE

INFORMATION SHOWN IS NOT GUARANTEED. THE CONTRACTOR IS

RESPONSIBLE FOR THE VERIFICATIONS OF ALL EXISTING CONDITIONS

PRIOR TO SUBMITTING BIDS. SITE VISITS PRIOR TO SUBMISSION OF

BIDS NEED TO BE FULLY COORDINATED WITH THE OWNER.

D. CIRCUIT INFORMATION FOR ALL AFFECTED CIRCUITS SHALL BE

VERIFIED PRIOR TO COMMENCING WORK. ACCURACY OF THE

INFORMATION SHOWN AND INCLUDED ON THE PANEL SCHEDULES IS

NOT GUARANTEED.

E. LUMINAIRES AND DEVICES INDICATED TO BE REMOVED, WHICH ARE

LOCATED ON CEILINGS OR WALLS, SHALL HAVE LUMINAIRES, DEVICE

AND ALL ASSOCIATED CIRCUIT WIRING AND CONDUIT REMOVED BACK

TO NEAREST JUNCTION BOX, OR DEVICE NOT INDICATED TO BE

REMOVED. ACTUAL CIRCUITING MUST BE DETERMINED IN THE FIELD.

THE CONTRACTOR SHALL PROVIDE ALL NECESSARY WIRE, CONDUIT,

DEVICES AND CONNECTIONS NECESSARY TO ENSURE CIRCUIT

CONTINUITY OF THE REMAINING DEVICES.

F. THE OWNER HAS THE RIGHT TO RETAIN ALL SALVAGEABLE MATERIAL.

ANY MATERIAL THE OWNER CHOOSES NOT TO ACCEPT SHALL BE

REMOVED FROM THE SITE AND PROPERLY DISPOSED OF BY THE

CONTRACTOR. CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF

ANY PCB BALLAST OR HAZARDOUS LAMPS.

G. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE

LABELING OF SPARE OR ABANDONED CIRCUITS AND/OR CIRCUIT

BREAKERS IN ALL PANELS AFFECTED BY DEMOLITION. SPARE

CIRCUITS AND/OR CIRCUIT BREAKERS MAY BE REUSED FOR THE

CIRCUITING OF THE NEW OR REMODELED AREA AS SPACE AND PANEL

LOADING WILL ALLOW.

H. THE CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR THE

PROPER RESTORATION OF ALL EXISTING SURFACES REQUIRING

PATCHING, PLASTERING, PAINTING AND/OR OTHER REPAIR DUE TO

THE DEMOLITION WORK DONE BY THE ELECTRICAL CONTRACTOR,

UNDER THE TERMS OF THIS SPECIFICATION. CLOSE AND SEAL ALL

OPENINGS, REPAIR ALL SURFACES, ETC., AS REQUIRED.

I. FIRE ALARM DEVICES SHALL BE REMOVED, REPLACED AND

CONNECTED TO NEW FIRE ALARM SYSTEM AS SPECIFIED. DUCT

SMOKE DETECTORS AND FIRE SMOKE DAMPERS SHALL BE REMOVED

ONLY WHEN THE ASSOCIATED MECHANICAL EQUIPMENT IS BEING

REMOVED.

J. EXISTING FIRE ALARM DEVICES, EMERGENCY LIGHTS AND EXIT SIGNS

SHALL BE COMPLETE AND OPERABLE AT ALL TIMES. PROVIDE

TEMPORARY DEVICES IN AREAS BEING WORKED ON TO ALLOW FOR A

WORKABLE SYSTEM DURING CONSTRUCTION.

K. PROVIDE MINIMUM [2] DAYS ADVANCE NOTICE OF OUTAGES.

COORDINATE WITH OWNER FOR ALL ANTICIPATED OUTAGES. OWNER

HAS FINAL APPROVAL ON TIME AND EXTENT OF POWER OUTAGE.

L. PROTECT EXISTING FURNITURE, CARPET AND OTHER

APPURTENANCES FROM DAMAGE DURING THE COURSE OF

CONSTRUCTION. REPLACE DAMAGED ITEMS FREE OF COST TO THE

OWNER.

M. ITEMS WHICH ARE INTENDED TO BE REMOVED, RELOCATED, OR

SALVAGED ARE SHOWN AS FULL-TONE LINES ON DEMO PLANS. ALL

OTHER ITEMS ARE INTENDED TO REMAIN IN PLACE AND ARE SHOWN

AS HALF-TONE.

A. COORDINATE LOCATION OF SWITCH HEIGHTS WITH CASEWORK,

FURNITURE AND EQUIPMENT LAYOUTS PRIOR TO ROUGH-IN. SEE

ARCHITECTURAL CASEWORK ELEVATIONS FOR CABINET HEIGHTS

AND LAYOUTS.

B. ALL OCCUPANCY SENSORS AND OCCUPANCY SENSOR SWITCHES

SHALL BE DUAL TECHNOLOGY (INFRARED AND ULTRASONIC).

OCCUPANCY SENSORS DO NOT SHOW RELAYS AND TOTAL WIRING

REQUIRED FOR PROPER OPERATION. PROVIDE A COMPLETE AND

FULLY FUNCTIONAL SYSTEM.

C. EMERGENCY, EXIT, AND NIGHT LIGHTS IN PATHS OF EGRESS SHALL

BE CONNECTED TO AN UNSWITCHED HOT LEG OF CIRCUIT SHOWN

UNLESS NOTED OTHERWISE.

D. ALL AREAS SHALL BE MANUAL-ON / AUTOMATIC-OFF UNLESS NOTED

OTHERWISE. AUTOMATIC-ON / AUTOMATIC-OFF PERMITTED IN

BATHROOMS, CORRIDORS, LOBBIES, SECURITY AREAS, AND AREAS

WHERE MANUAL-ON WOULD ENDANGER OCCUPANT SAFETY AS

DICTATED BY OWNER.

E. ALL DIMMERS SHALL BE SET TO 50% START LEVEL UNLESS NOTED

OTHERWISE.

F. THE LIGHTING SUBMITTALS SHALL BE PREPARED AND SUBMITTED BY

AN AUTHORIZED FACTORY REPRESENTATIVE OR THE SUBMITTALS

WILL BE REJECTED.

A. ALL DEVICES SHOWN SHALL BE MOUNTED AT 18" A.F.F. UNLESS

INDICATED OTHERWISE.

B. EACH LOW VOLTAGE CABLE SHALL HAVE INDIVIDUAL RUN BACK TO

TERMINATION POINT AT EXISTING BACKBOARD . LEAVE 10' OF COILED

CABLE AT TELEPHONE BOARD LOCATION. DATA/TELEPHONE CABLING

SHALL BE (1) CAT 6 TO EACH DEVICE.

C. ALL AUXILIARY CABLE ABOVE CEILING SHALL BE PLENUM…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .