1.Buck and Rail Fence (Gov supplied, 2. Seatwall at VC plaza contractor installed)
3. Seatwall at VC plaza 4. Seatwall at VC plaza
5. Seatwall at VC plaza (gaps in cap joints) 6. Seatwall at VC plaza (gaps in cap joints)
The seat wall grout looks good no repointing needed. The stone slabs between the wall and curb are not grouted (dry set refer to detail). The cap stones and stone slabs were not cut to fit a radius, so the joints become large on the plaza facing end of the joints. The sand added between the joints is washing out onto the seat wall.