This document is a Delivery Order detailing a request from the United States Army Medical Research Institute for Infectious Diseases (USAMRIID) for two Kilobaser Nitrogen Generators and associated reagents. The procurement is for the Diagnostics Systems Division (DSD) and Molecular Biology (MOL BIO) Division, with specific requirements including a portable generator weighing 50lbs or less, compatible with the Kilobaser ONE-XT DNA and RNA Synthesizer, and providing remote service within 24 hours.

The order includes a comprehensive list of anticipated consumables for Fiscal Year 2025, such as DNA cartridges, chips, quencher chips, and oligo purification kits. Delivery is specified for Fort Detrick, MD, with coordination through Dr. Jeffrey Koehler and Dr. Mariano Sanchez-Lockhart. The solicitation is associated with the Defense Health Agency, with the solicitation number HT9425-25-QE010, and involves procurement of equipment for synthesizing standard and advanced oligonucleotides, including software, touch screen, gas appliances, and online training.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

United States Army Medical Research Institute for Infectious Diseases (USAMRIID) Minimal Essential Characteristics (MEC) Delivery Order 1 The Diagnostics Systems Division (DSD) and Molecular Biology (MOL BIO) Division within USAMRIID requests two (2) Kilobaser Nitrogen Generators and associated reagents meeting the following MECs:

1) Nitrogen Generators shall be:

Size:

· Generator must be easily portable (50lbs or less) and shall not exceed dimensions of 15” x 15” x 15” due to limited benchtop space and portability requirements.

· The instrument must be capable of being carried by a person to a remote location.

Performance:

· Generator must be capable of working in conjunction with Kilobaser ONE-XT DNA and RNA Synthesizer.

· Generator must produce the necessary nitrogen required to operate the Kilobaser ONE-XT DNA and RNA Synthesizer to synthesize DNA and RNA.

· Generator must operate with the Kilobaser ONE-XT DNA and RNA Synthesizer as provided.

Service:

· The contractor shall provide service remotely within 24 hours. If the Kilobaser Nitrogen Generator G2N cannot be repaired remotely, a new device shall be supplied within one week during the one-year warranty period. Each purchase price shall include a one-year warranty.

· All software licensing, warranty, and services associated with the equipment shall be in accordance with Original Equipment Manufacturer (OEM) terms and conditions.

DSD and MOL BIO anticipate the following consumables in FY25:

Division
Consumables Description
QTY
DSD
6-FAM DNA - Cartridge
200
Standard DNA-Cartridge
125
BHQ-1 Quencher - Chip
115
Standard - Chip
200
OilPure HIC Column Oligo Purification Kit
33
MOL BIO
Standard - Chip
16
Standard DNA-Cartridge
16
Biotin - Cartridge
3
Biotin - Chip
3
Phosphorylation - Cartridge
3
Phosphorylation - Chip
3
OilPure HIC Column Oligo Purification Kit
6

Delivery Requirements Items shall be shipped to:

United States Army Medical Research Institute of Infectious Diseases (USAMRIID) 1425 Porter Street Fort Detrick, MD 21702

Delivery of items shall be coordinated with:

Name: Dr. Jeffrey Koehler/Dr. Mariano Sanchez-Lockhart Email: jeffrey.w.koehler4.civ@health.mil/ mariano.sanchez-lockhart.civ@health.mil Phone: (301) 619-8342/(301) 619-3279