This Scope of Work (SOW) details the repair of wastewater lagoon liners at Chaco Culture National Historical Park in New Mexico. The project involves replacing the 45 mil reinforced polypropylene (RPP) geomembrane liner on the south-facing berms and corners of the southeast and northeast lagoon cells, with an estimated liner replacement area of 13,750 square feet. The work includes digging new anchor trenches, installing vents, and relaying geocomposite vent strips.

The project stems from damage caused by a 2024 windstorm and subsequent UV degradation, with the objective of restoring lagoon capacity until complete liner replacement. Specific tasks include site verification, wastewater transfer between cells, cleaning existing liner surfaces, and precise liner installation techniques. Performance requirements specify work between 8 am-5 pm on weekdays, with onsite work limited to 30 calendar days. The construction delivery date is set for 60 calendar days after the Notice to Proceed, with the government expecting to issue the notice 30 calendar days after award.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scope of Work (SOW)

Repair Lagoon Liners

Chaco Culture National Historical Park

PMIS 335678

Table of Contents

1.0 Project Description / Summary

2.0 Objectives

3.0 Background

4.0 Specific Work / Tasks

5.0 Submittals

6.0 Place of Performance

7.0 Performance Period / Schedule Requirements

System Pictures

Scope of Work Task Order / Project Title: Repair Lagoon Liners

Park / Park Unit: Chaco Culture National Historical Park

Date: February 21, 2025

1.0 PROJECT DESCRIPTION / SUMMARY:

This project consists of repairing the southeast and northeast cells of the wastewater lagoons.

See highlighted area of attached plan set 310/106386A and pictures.

Repairs consist of replacing the 45 mil reinforced polypropylene (RPP) geomembrane liner on the south facing berms and corners. Estimated area of liner to be replaced is 13,750 square feet.

Work will include digging a new anchor trench, vents, and relaying necessary sections of geocomposite vent strips.

2.0 OBJECTIVES:

This project is intended to restore the capacity of the lagoons until the liners are completely replaced.

3.0 BACKGROUND:

During 2024, a windstorm tore the liner on the southeast cell. During a January 2025 inspection, damages were found on the northeast cell. It appears the south facing portions of the liner have suffered UV degradation. The remaining sections of the liner are in good condition.

4.0 SPECIFIC WORK / TASKS:

a. Contractor to visit site to verify existing conditions before submitting bid. Contractor shall account for any changes that may have occurred between writing this scope of work and construction.

b. Transfer wastewater between cells to allow for the lining process.

c. Move sludge and clean existing liner in areas where new liner will be welded to the existing liner.

d. New liner will be 45 mil RPP.

e. Contract Line Item 1: South East Cell Remove damaged liner. Remove any rocks that could damage new liner. Dig new anchor trench. Attach and weld new liner at the bottom of the cell and past corners, to undamaged areas on existing liner. Relay geo-composite strip vents, install new vents in liner, and anchor new liner and geocomposite strips in new anchor trench.

f. Contract Line Item 2: North East Cell Remove any rocks that could damage new liner.

Excavate and expose undamaged liner in anchor trench. Attach new liner at the bottom of the cell, past corners, and undamaged liner in anchor trench. New liner will be installed over damaged liner. Install vents in new liner.

g. Dispose of removed liner and any construction refuse.

5.0 LINER SPECIFICATION AND SUBMITTALS:

a. Submit manufacturer’s information and sample for proposed liner material.

The geo membrane liner shall be industrial grade reinforced polypropylene manufactured from 100% virgin raw materials that are specifically compounded for use in hydraulic structures. It shall possess the following properties.

45 mil, reinforced polypropylene liner as manufactured by Carlisle Syntec Systems or approved equal.

Physical Property Test Method Property Of Unaged Sheet Property After Aging 30 days

Tolerance on nominal thickness, % ASTM D 5199 ± 10

Thickness over scrim, in. (mm) 36-mil 45-mil 60-mil

ASTM D 4637

Optical Method

0.010 (0.254) min.

0.013 (0.330) min.

0.018 (0.457) min.

Mass per unit area, lb/ft2 (g/ ft2) (kg/m2) 36-mil 45-mil 60-mil

ASTM D 5261

0.17 (77) (0.83) typical

0.21 (95) (1.03) typical

0.29 (132) (1.42) typical

Breaking strength, lbf (kN) (grab tensile at strain rate of 12 in./min.)

36-mil 45 & 60-mil

ASTM D 751

Grab Method A

200 (0.9) min. 260 typ.

250 (1.1) min. 300 typ.

200 (0.9) min. 260 typ.

250 (1.1) min. 300 typ.

Elongation at break of fabric, % ASTM D 751 25 typical 25 typical

Tearing strength, lbf (N) (2 in. / min. strain rate) 36-mil 45 & 60-mil

ASTM D 5884

(max. load)

80 (356) min. 130 (578) typ.

100(445) min. 160 (712) typ.

Low temperature flexibility, °F (°C) ASTM D 2136 1/8 in.

mandre l 4 hour temp

- 40 (- 40) max.

- 50 (- 46) typical

Linear Dimensional Change (shrinkage), % ASTM D 1204 +/- 1.0 max.

- 0.5 typical

Ozone resistance, 100 pphm, 168 hours ASTM D 1149 No cracks No cracks Resistance to water (distilled) absorption After 30 days immersion 122 °F (50 °C) Change in mass, %

ASTM D 471

(coating compound)

1.0 max.

0.5 typical

Hydrostatic resistance, lbf/in.2 or psi (MPa) (Mullen burst) 36-mil 45-mil 60-mil

ASTM D 751

Procedure A

350 (2.4) min.

400 (2.8) typical 450 (3.1) typical 500 (3.4) typical

350 (2.4) min.

400 (2.8) typical 450 (3.1) typical 500 (3.4) typical

Field seam strength, lbf/in. (kN/m) Seam tested in peel after weld

ASTM D 4437

1 in. wide

30 (5.3) min.

60 (10.5) typical

Water vapor permeance, Perms ASTM E 96 0.10 max.

0.05 typical

Puncture resistance, lbf (N) 36-mil & 45-mil 60-mil

ASTM D 4833

(index puncture)

85 (378) min.

110 (489) typical 120 (534) typical

Resistance to xenon-arc weathering1

Xenon-Arc, 15,120 kJ/m2 total radiant exposure, visual condition at 10X

ASTM G 155

0.70 W/m2 80 °C

B.P.T.

No cracks No loss of breaking or tearing strength

6.0 PLACE OF PERFORMANCE:

a. The project is located at Chaco Culture National Historical Park in northern New Mexico.

More information and directions can be found at https://www.nps.gov/chcu/index.htm

b. The wastewater lagoons are located on a mesa (bluff) above the headquarters area.

Coordinates are 36.035229, -107.902455.

c. Access to the site is by a dirt road which may be impassable for two-wheel drive vehicles during rainy or snowy weather.

d. Access to the site is difficult for 18-wheel tractor trailer trucks.

7.0 PERFORMANCE PERIOD / SCHEDULE REQUIREMENTS:

a. Work shall be performed between the hours of 8 am -5 pm on weekdays. Extended, weekend, and holiday work may be allowed as approved by park facility manager with at least one weeks’ notice.

b. Onsite work will be limited to 30 calendar days.

c. Construction Delivery Date is 60-calendar days after Notice to Proceed - the government expects to issue the Notice to proceed 30-calendar days after award.

Site Pictures

South East Cell

North East Cell

CAWalker Polygonal Line

CAWalker Polygonal Line

CAWalker Callout Repair liner in these areas per directions in scope of work.

CAWalker Line

The geo membrane liner shall be industrial grade reinforced polypropylene manufactured from 100% virgin raw materials that are specifically compounded for use in hydraulic structures. It shall possess the following properties.
45 mil, reinforced polypropylene liner as manufactured by Carlisle Syntec Systems or approved equal.