This document is a site layout and associated plans PDF for the Buttrick Cottage and Carriage House Roof Replacements project at Minute Man National Historical Park in Concord, Massachusetts, dated 6/22/2025. The plans provide detailed technical specifications for a comprehensive roof replacement, including:

Key technical details include replacing roof shingles with 3-tab asphalt shingles, installing waterproof self-adhering underlayment, replacing wood gutters with 5-inch 16-20oz copper half-round gutters, and implementing copper flashing and downspout modifications. The project involves meticulous preservation of historical elements, with specific instructions to minimize damage to original building components. The site plan shows the location of the Buttrick Cottage and Carriage House, staging areas, contractor parking, and designates an area to remain open for park staff during construction.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Buttrick Cottage and Carriage House Roof

Replacements

Date: 6/22/2025

Minute Man National Historical Park 174 Liberty St Concord Ma 01742

Site Layout & Associated Plans

Page: 1

Date: 6/22/2025

Minute Man National Historical Park 174 Liberty St Concord Ma 01742

Buttrick Cottage and Carriage House Roof

Replacements

Site Layout & Associated Plans

Page: 2

Historical Park 174 Liberty St Concord Ma 01742

Buttrick Cottage and Carriage House Roof

Replacements

Indicating areas for waterproof self-adhering underlayment.

Typical, throughout.

Wrap around Boston style wooden gutter with mitered corners. Existing 4 lead goose neck downspouts to be replaced with primed copper hand bent goose neck downspouts.

Site Layout & Associated Plans

Page: 3

Bu ttr ic k

C ot ta ge

H ou se pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Line pmcpherson Oval pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line

Historical Park 174 Liberty St Concord Ma 01742

Replace with 5-inch 16-20oz copper half round gutter.

Mount in similar fashion using compatible metal hardware.

Replace roof on louvered vent cupola. Care to be taken to not damage original building elements.

Flashing incorporated with skylight be saved in place if posable. Where reconstruction of flashing is needed care should be given to emulate means and methods of existing.

Retain open valley exposure measurements and materials throughout.

Noted example of copper cap over sleeve to be implemented throughout.

Indicating areas for waterproof self-adhering underlayment. Typical, throughout.

Buttrick Cottage and Carriage House Roof

Replacements

Site Layout & Associated Plans

Page: 4

Bu ttr ic k

C ar ria ge

H ou se pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Oval pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Oval pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line

Historical Park 174 Liberty St Concord Ma 01742

EXISTING BRICK MASONRY WALL

L.C.C. REGLET FLASHING; SET WITH LEAD WEDGES

AT 8" O.C. AND SECURE WITH CLIPS

SELF-ADHERED MEMBRANE; EXTEND 36" MINIMUM

ONTO ROOF DECK

BREATHABLE MEMBRANE

NYLON DRAINAGE MATRIX (AT WOOD SHINGLES

ONLY)

BASE FLASHING; PROVIDE 3" MINIMUM LAPS

ASPHALT, SLATE, OR WOOD SHINGLES

EXISTING WOOD ROOF DECK

3" TOP LAP

5"

5"

7-1/2"

SHEET METAL FLASHING

NAIL FLASHING TO ROOF ONLY

SHINGLES

APPLICATION OF STEP FLASHING

NOT TO SCALE

COUNTERFLASHING NOT

SHOWN FOR CLARITY

6"

4' ' M

IN

NOTE:

AT CHIMNEY CORNERS

EXTEND CRICKET AND

APRON FLASHING 4''

MINIMUM ONTO SIDES OF

CHIMNEY.

6'' MIN.

SOLDERED; TYPICAL

1/2'' HEMMED EDGE

APRON

8' ' M

IN

REGLET FLASHING; SET

WITH LEAD WEDGES AT

8'' O.C. AND SECURE

WITH CLIPS

INDIVIDUAL STEP

FLASHING; SIZE OF

PANS TO MATCH

EXISTING, PROVIDE

3'' MINIMUM LAPS

NOTE: INSTALL

SELF-ADHERED MODIFIED

BITUMEN FLASHING

MEMBRANE BELOW SHEET

METAL FLASHINGS AND

EXTEND 36'' ONTO ROOF

DECK

SEALANT TOOLED TO

SHED WATER

REGLET FLASHING; SET

WITH LEAD WEDGES AT

8" O.C. AND SECURE

WITH CLIPS

LEAD-COATED COPPER

STEP FLASHING

ASPHALT, SLATE,

OR WOOD

SHINGLES

DETAIL 'A'

REGLET DETAIL

A

8" M

IN

8" M

IN

4"

4"

4"

4"

PROVIDE PREFORMED

COPPER CAP OVER SLEEVE

PROVIDE COPPER FLASHING

SLEEVE AROUND PIPE;

PROVIDE ROSIN PAPER AT

OVERLAP WITH BREATHABLE

MEMBRANE.

ADD'L SELF- ADHERED

WATERPROOFING

MEMBRANE FLASHING

SELF-ADHERED

WATERPROOFING

MEMBRANE

ROOF

SHINGLES

1 EAVE DETAIL AT WOOD GUTTER

A5.2

E

ROOF CEMENT

FASTENER EA. SIDE OF RIDGE

1" DABS OF ROOF CEMENT ON

FIELD SHINGLES

3 TAB ASPHALT SHINGLES

PRE-CUT RIDGE

SHINGLES

FELT UNDERLAYMENT

WATERPROOF MEMBRANE

CONTINUOUS 18" EITHER SIDE OF

RIDGE

FLASHING AT PIPE PENETRATION

SCALE:

A5.2 E

CHIMNEY FLASHING SCHEMATIC

SCALE:

A5.2 E

STEP FLASHING DETAIL AT BRICK CHIMNEYS

SCALE:

A5.2 E

2 RIDGE DETAIL AT ASPHALT SHINGLE ROOFING

A5.2

3 TAB ASPHALT SHINGLES

EXPOSURE BASED ON MFG.

RECOMMENDATIONS FOR

SHINGLE SIZE; TYPICALLY 5 -

5.5 INCHES

SELF-ADHERED WATERPROOFING

MEMBRANE; SEE ROOF PLAN FOR

EXTENT.

DOUBLE STARTER COURSE

12" STRIP OF WATERPROOF

MEMBRANE OVER DRIP EDGE

WATER PROOF MEMBRANE;

EXTEND MIN. 1'-0" BEYOND WALL

STRUCTURE AND LAP DOWN

FASCIA BEHIND GUTTER

PROVIDE LCC DRIP EDGE

REPLACE EXISTING WOOD

GUTTER IN-KIND; MATCH PROFILE;

PROVIDE RABBETTED LEG

EXTENSION AS REQ. TO SET

GUTTER AT CORRECT HEIGHT TO

CAPTURE ROOF RUNOFF

TREAT WOOD GUTTER INTERIOR

WITH PENETRATING SEALER.

PRIME & PAINT EXTERIOR FACES

ONLY; MATCH EXISTING COLOR

SCHEME.

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

CADD:

REHABILITATE STRUCTURES FOR LEASING

GREAT AMERICAN OUTDOORS ACT (GAOA)

MINUTE MAN NATIONAL HISTORICAL PARK

DRAWING No.

PMIS No.

SHEET

317529

06/02/2022

BMM

BMM

HACE

181576

A5.2

TITLE OF SHEET

TYPICAL

ROOFING DETAILS

SCALE

SCALE OF FEET

E

SCALE

SCALE OF FEET

C

EAVE DETAIL AT WOOD GUTTER

ROOF CEMENT.

FASTENER EA. SIDE OF RIDGE.

1" DABS OF ROOF CEMENT ON FIELD

SHINGLES.

3 TAB ASPHALT SHINGLES.

PRE-CUT RIDGE

SHINGLES

BREATHABLE UNDERLAYMENT

WATERPROOF MEMBRANE

CONTINUOUS 18" EITHER SIDE OF

RIDGE

RIDGE DETAIL AT ASPHALT SHINGLE ROOFING

3 TAB ASPHALT SHINGLES EXPOSURE BASED ON MFG.

RECOMMENDATIONS FOR SHINGLE SIZE; TYPICALLY 5 -

5.5 INCHES SELF-ADHERED WATERPROOFING MEMBRANE;

SEE ROOF PLAN FOR EXTENT.

DOUBLE STARTER COURSE

12" STRIP OF WATERPROOF MEMBRANE OVER DRIP EDGE

WATER PROOF MEMBRANE; EXTEND MIN. 1'-0" BEYOND

WALL STRUCTURE AND LAP DOWN FASCIA BEHIND

GUTTER.

PROVIDE ALUMINUM DRIP EDGE

REPLACE EXISTING WOOD GUTTER IN-

KIND; MATCH MITTERED CORNERS; MATCH PROFILE;

PROVIDE RABBETTED LEG EXTENSION AS REQ.

TO SET GUTTER AT CORRECT HEIGHT

TO CAPTURE ROOF RUNOFF.TREAT WOOD GUTTER

INTERIOR WITH PENETRATING SEALER.

PRIME & PAINT EXTERIOR FACES

ONLY; MATCH EXISTING COLOR

SCHEME.

EXISTING WOOD ROOF DECK

ASPHALT SHINGLES

BASE FLASHING; PROVIDE 3" MINIMUM LAPS

BREATHABLE MEMBRANE

EXISTING BRICK MASONRY WALL

L.C.C. REGLET FLASHING; SET WITH LEAD WEDGES AT 8" O.C. AND SECURE WITH CLIPS

SELF-ADHERED MEMBRANE; EXTEND 36" MINIMUM ONTO ROOF DECK

STEP FLASHING DETAIL AT BRICK CHIMNEYS

PROVIDE COPPER FLASHING SLEEVE

AROUND PIPE; PROVIDE ROSIN PAPER

AT OVERLAP WITH BREATHABLE

MEMBRANE.

ROOF SHINGLES

ADD'L SELF- ADHERED WATERPROOFING

MEMBRANE FLASHING

4'

M

IN

3" TOP

LAP

7-1/2"

SHEET METAL FLASHING NAIL

FLASHING TO ROOF ONLY

SHINGLES

COUNTERFLASHING NOT

SHOWN FOR CLARITY

8"

M

IN

8"

M

IN

4"

4"

4"

4"

PROVIDE PREFORMED

COPPER CAP OVER SLEEVE

FLASHING AT PIPE PENETRATION

SELF-ADHERED WATERPROOFING MEMBRANE

Buttrick Cottage and Carriage House Roof

Replacements

Site Layout & Associated Plans

Page: 5 pmcpherson Rectangle pmcpherson Rectangle pmcpherson Rectangle pmcpherson Rectangle pmcpherson Line pmcpherson Line pmcpherson Line

Polygonal Line

Historical Park 174 Liberty St Concord Ma 01742

66'' MIN.

SOLDERED; TYPICA

1/2'' HEMMED EDGE

APRON

REGLET FLASHING; SET

WITH LEAD WEDGES AT

8'' O.C. AND SECURE WITH

CLIPS INDIVIDUAL STEP

FLASHING; SIZE OF PANS

TO MATCH EXISTING,

PROVIDE

3'' MINIMUM LAPS

NOTE: INSTALL

SELF-ADHERED MODIFIED BITUMEN FLASHING

MEMBRANE BELOW SHEET METAL FLASHINGS

AND EXTEND 36'' ONTO ROOF DECK

ASPHALT SHINGLES

CHIMNEY FLASHING SCHEMATIC

SEALANT TOOLED

TO SHED WATER

REGLET FLASHING;

SET WITH LEAD

WEDGES AT 8" O.C.

AND SECURE WITH

CLIPS

LEAD-COATED

COPPER STEP

FLASHING

REGLET DETAIL

Buttrick Cottage and Carriage House Roof

Replacements

Site Layout & Associated Plans

Page: 6 pmcpherson Line pmcpherson Line pmcpherson Rectangle pmcpherson Rectangle pmcpherson Line

Historical Park 174 Liberty St Concord Ma 01742

STUCCO DRIP EDGE

EXISTING BACKUP MASONRY TO

REMAIN, TYP. REPAIR AS NEEDED

TRADITIONAL 3-COAT STUCCO

SYSTEM

CASING BEADS

NEW S.S. DRIP EDGE WITH

HEMMED EDGE

PREPARE, PRIME AND PAINT

EXISTING WOOD TIMBER

1/2"

EXISTING BACK-UP

MASONRY TO REMAIN,

TYP. REPAIR AS NEEDED

TRADITIONAL THREE-COAT STUCCO

SYSTEM

GALVANIZED CONTROL JOINT BEADS

STUCCO CONTROL JOINT AND END DETAILS

SEALANT JOINT PER

5/A502 GALVANIZED

CASING BEADS

1/2"

CONTROL JOINT EXPANSION JOINT

END JOINT END JOINT @ BASE OF STUCCO

WEEP

SCREED

CASING BEADS

SEALANT JOINT

PER 5/A502

OUTSIDE CORNER, TYP.

OUTSIDE CORNER AT FASCIA/SOFFIT

REENTRANT CORNER, TYP.

REENTRANT CORNER AT MATERIAL CHANGE

CORNER BEADS, FILL

INSIDE WITH SCRATCH

COAT MATERIAL

DRIP MOLD WITH

WEEP HOLES

CASING

BEADS

CORNER

BEADS

SEALANT PER

5/A502 CASING

BEADS

EXISTING BACK-UP

MASONRY TO REMAIN,

TYP. REPAIR AS

NEEDED

EXISTING BACK-UP

MASONRY TO REMAIN,

TYP. REPAIR AS

NEEDED

MIN. 12" SIDE LAPS & 1" END LAPS

EXISTING BRICK OR STONE MASONRY BACK-UP

TO REMAIN

SELF-FURRING METAL ATTACHED

TO SUBSTRATE WITH 11

2" POWDER-ACTUATED

FASTENERS WITH WASHERS @ 8" o.c. IN BOTH

DIRECTIONS

TRADITIONAL THREE-COAT STUCCO SYSTEM TO

MATCH EXISTING COLOR, TEXTURE AND

PROFILE.

DETAIL

SECTION

EXISTING BRICK MASONRY BACK-UP

TO REMAIN

ORIENT LATH SECTION SLOPING DOWN

AWAY FROM SUBSTRATE AS SHOW

STUCCO REPAIR AND REPLACEMENT DETAILS

Buttrick Cottage and Carriage House Roof

Replacements

Site Layout & Associated Plans

Page: 7 pmcpherson Line pmcpherson Line pmcpherson Line pmcpherson Line

File details come from the government source that posted it. Updated .