B08_-_Attachment_1_-_Specifications_for_Hardware_rev1.pdf

PDF 153 KB Posted

Attached to
GLAC: LOG GUARDRAIL HARDWARE - STUDS AND HEX NUTS
Solicitation number
140P1424Q0062
Issued by

About this file

This document contains the specifications for hardware required for a National Park Service project at Glacier National Park. The project is for the procurement of 2,000 1"x 4" A193 B7 double threaded studs and 2,000 1" ACME threaded nuts with washer face for use in a log guardrail project on the Going-to-the-Sun Road. The hardware must be delivered by April 26, 2024 to the specified address in West Glacier, Montana. The document also includes details on a related sole source federal contract opportunity for the hardware, which will be awarded under simplified acquisition procedures and classified under NAICS code 332722 with a 500 employee size standard. The government is seeking input from interested firms that believe they can meet the hardware specifications prior to making a determination on whether to compete the procurement.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

National Park Service

Park: Glacier National Park

Project: Hardware for Going to the Sun Road (GTTSR) Guard Railing

Date: 17 January 2024

Deliver to Address: 61 Scoyen Circle, West Glacier, MT 59936

Deliver by: 26 April 2024

Specifications for Studs/Nuts

Quantity 2000 – 1"x 4” A193 B7 Double threaded studs. Double ended studs will be 1.25" Of 8-Thrd/In.

UNC-2A Standard Thread on one side and 8-Thrd/In. ACME General Purpose Thread on other side.

ACME thread will have a 5/8” tapered end.

Quantity 2000 – 1” ACME threaded nut with washer face.

Contractor shall ship a prototype double ended stud with nut, in conjunction with the quote, for approval from COR prior to manufacturing remaining quantity.

Prototype Example:

***NOTE: This prototype sample is for illustrative purposes only. All measurements must match the specifications outlined above.