B08_Attachment 0005_ME Broad Equipment List FY26.xlsx

XLSX spreadsheet 61 KB Posted

Attached to
Maintenance and Repair of Manufacturing Equipment and Systems Used in Explosive and Non-Explosive Operational Environments
Solicitation number
W519TC-25-Q-MESE
Issued by

About this file

This document is a comprehensive Preventative Maintenance List for Crane Army Ammunition Activity's manufacturing equipment and systems across multiple facility locations. The maintenance plan covers quarterly, semi-annual, and annual preventative maintenance for a wide range of industrial machinery including robotic welders, CNC mills, lathes, waterjet systems, presses, ovens, laser cutters, and specialized munitions-related equipment.

The maintenance solicitation (W519TC-25-Q-MESE) seeks commercial services for maintaining equipment in both explosive and non-explosive operational environments, with a NAICS code of 811310 and a small business size standard of $12,500,000. The contract includes four primary contract line items (CLINs): Equipment Quarterly Maintenance, Equipment Semi-Annual Maintenance, Equipment Annual Maintenance, and Emergency Repairs, with a performance period of 365 days from the date of award. The maintenance activities involve detailed technical inspections, lubrication, parts replacement, safety checks, calibration, and operational testing across diverse manufacturing equipment located in different facility divisions such as MEC, MED, MEO, MEP, MES, and SEM.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PM - Quarterly

Crane Army Ammunition Activity
Maintenance and Repair of Manufacturing Equipment and Systems Used in Explosive and Non-Explosive Operational Environments
Quarterly Preventative Maintenance List
DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Number
MEDB138Fryer Easy TurnNoLathe137797a) Inspect coolant pump and filters

b) Check gearbox oil level and add as necessary

c) Inspect pneumatic FRL

d) Inspect way lube level and add as necessaryET-25
MEDB138FanucNoRobot137796a) Inspect Pneumatic FRL

b) Grease joints, bushing and balancer housing

c) Inspect and adjust limits as necessary

d) Inspect all cables, harnesses, connectors, controllers, and power supplies

e) Inspect and tighten all bolts to spec.

f) Check for defective seals

g) OEM recommendations 1704202

DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Number
MEOB2734Pflow IndustriesNoPowder Elevator180278a) Ensure proper lockout procedures are adhered to where applicable

b) Ensure proper fall arrest systems are utilized while working at heights.

c) Hydraulic Power Unit (HPU)

- Visually inspect for signs of damage.

- Observe operation and inspect for abnormal noise.

- Qualified Electrical Worker, check amp draw of motor and verify it is within normal operating parameters.

- Check for leaks.

- Check for Oil level, add Dexron III ATF as required.

d) Lift Chains

- Visually inspect chain for signs of rust, damage or deformed components.

- Lubricate as required with Fluid Film Protectant and Lubricant or equivalent.

e) Anchor Fasteners

- Visually inspect column base plates and foundation anchor fasteners for corrosion & verify tightness.

- Visually inspect the bracing for damage and fitness.

f) Structure

- Visually inspect Carriage for fit up.

- Visually check for corrosion.

g) Qualified Electrical Worker Inspect GAte Interlocks and Push Button (PB) Stations Check Level 1 VA Gate Interlock and Level 2 Swing Gate Interlock for the following:

- Check for loose attachment, proper operation, and alignment of all interlocks. Lubricate door latches and ensure door latches smoothly operate.

- Check engagement of interlock keeper.

- Check roller assembly and cable assembly for smooth operation (lubricate as necessary).

- Verify that the interlock functions properly when actuated by the roller assembly located on the VRC columns.

- Verify that gate does not open when carriage is not present.

- Verify that carriage cannot move when gate is open.

Check Level 1 and Level 2 PB Stations for the following:

- Check operation of each push button.

- Inspect for damage and verify each bezel is snug.

- Verify condition & operation of control panel light.

h) Paint

- Visually check for corrosion (unit is hot dipped galvanized).

- Use wire brush to remove any corrosion found and touch up with Z.R.C cold galvanizing compound or equal as required. Series 21

PM - Semi-Annual

Crane Army Ammunition Activity
Maintenance and Repair of Manufacturing Equipment and Systems Used in Explosive and Non-Explosive Operational Environments
Semi-Annual Preventative Maintenance List
DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MECB145FanucNoRobomill232775, 36763Check and Clean all Air/Fan Filter, Replace or clean if contaminated

Check Fan Motors for Excess Wear or Damage, the ones that exchange Outside Air into Cabinets Replace all Fluids if applicable Check, Clean and Lubricate Tool Changer Change CNC Control Back-up Batteries (4 D-cells) Check Tram of Spindle to Table, Document Check and Clean Safety Interlocks Check Machine Lubricant Grease/Oil, Change Grease Cartridge or Top off Resevior, Replace Way Oil if Contaminated Remove and Inspect Axis Covers and Wipers, clean any debris Clean and Inspect Liners Guides and Ways Monitor Servo and Spindle Motor Current Draw, Document Check Electrical Cabinet, Clean Interior Check for Loose or Damaged Wire Connections Check all External Cables Wires and Hoses for Damage Check Machine Level, Document Visually Inspect Outside of Machine and report any abnormalities or Safety Concerns Check Files for Error Messages that need attention Clear all Clocks Check and Clean all Limit Switches T14iF and D14MiB5

DIVLocationBrandWarrenty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MECB200FanucNoRobomill132806Check and Clean all Air/Fan Filter, Replace or clean if contaminated

Check Fan Motors for Excess Wear or Damage, the ones that exchange Outside Air into Cabinets Replace all Fluids if applicable Check, Clean and Lubricate Tool Changer Change CNC Control Back-up Batteries (4 D-cells) Check Tram of Spindle to Table, Document Check and Clean Safety Interlocks Check Machine Lubricant Grease/Oil, Change Grease Cartridge or Top off Resevior, Replace Way Oil if Contaminated Remove and Inspect Axis Covers and Wipers, clean any debris Clean and Inspect Liners Guides and Ways Monitor Servo and Spindle Motor Current Draw, Document Check Electrical Cabinet, Clean Interior Check for Loose or Damaged Wire Connections Check all External Cables Wires and Hoses for Damage Check Machine Level, Document Visually Inspect Outside of Machine and report any abnormalities or Safety Concerns Check Files for Error Messages that need attention Clear all Clocks Check and Clean all Limit Switches D14MiB5

DIVLocationBrandWarrenty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MECB2520FanucNoRobomill137865Check and Clean all Air/Fan Filter, Replace or clean if contaminated

Check Fan Motors for Excess Wear or Damage, the ones that exchange Outside Air into Cabinets Replace all Fluids if applicable Check, Clean and Lubricate Tool Changer Change CNC Control Back-up Batteries (4 D-Cells) Check Tram of Spindle to Table, Document Check and Clean Safety Interlocks Check Machine Lubricant Grease/Oil, Change Grease Cartridge or Top off Resevior, Replace Way Oil if Contaminated Remove and Inspect Axis Covers and Wipers, clean any debris Clean and Inspect Liners Guides and Ways Monitor Servo and Spindle Motor Current Draw, Document Check Electrical Cabinet, Clean Interior Check for Loose or Damaged Wire Connections Check all External Cables Wires and Hoses for Damage Check Machine Level, Document Visually Inspect Outside of Machine and report any abnormalities or Safety Concerns Check Files for Error Messages that need attention Clear all Clocks Check and Clean all Limit Switches D14MiB5

DIVLocationBrandWarrenty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MEDB138Fryer Easy TurnNoLathe137797a) Inspect hoses for cracking
b) Drain coolant tank, clean and replace coolantET-25
MEDB138FanucNoRobot137796a) Clean cooling fans and filters
b) any other OEM recommendations1704202
DIVLocationBrandWarrenty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MEOB2734Pflow IndustriesNoPowder Elevator180278Ensure proper Lockout procedures are adhered to where applicable!!!

Ensure proper fall arrest systems are utilized while working at heights.

a) Safety Cam Inspections

- Visually inspect safety cam shaft for signs of wear and damage.

- Visually inspect chain to safety cam connector and master link.

- Check wheel block column shoe for corrosion and hardware tightness.

b) Safety Cam Rotation

- Lower the carriage to the bottom level.

- Open the manual release valve on the Hydraulic Power Unit (page 15 of owner’s manual) The valve opens by pulling upwards.

- With the manual release valve opened, slacken the drive chain by pulling on it (this may take considerable force as you are extending the cylinders). Check to see that the safety cams rotate freely and that they are able to touch the column without obstruction.

- Close the manual release valve (you may need to tap lightly a few times on the plunger to ensure the valve seats).

- Check to make sure that the chains are properly aligned on the sprockets.

- Cycle the lift several times to check for proper operation.

c) Chain Sprockets

- Visually inspect Lift Header Sprockets for alignment and wear.

- Visually inspect Cylinder End Sprockets for alignment and wear.

Annual 3000lb PFlow Munitions Lift Ensure proper Lockout procedures are adhered to where applicable!!!

Ensure proper fall arrest systems are utilized while working at heights.

d) Synchronization Shaft

- Visually inspect for signs of damage and corrosion.

- Check key fit up.

- Spray Liberally with Corrosion protective lubricant (Fluid Film or equivalent).

e) Shaft Pillow Block Bearings and Cylinder End Clevis Assemblies.

- Verify set screws are tight.

- Lubricate bearings with Mobil EP2 or equivalent lithium-based grease (no more than one pump per bearing!).

f) Hydraulic Power Unit

- Drain oil, clean sump, replace oil with Dexron III ATF.

- Replace filter with 10-micron hydraulic filter (Donaldson P551551 or equivalent).Series 21
MEOB2734METTLER TOLEDONOMetal Detector136894Visually inpsect and adjust as required.

1. Support Frame

2. Mounting Plates

3. Fixed Feet

4. Detector Head

5. Liner

6. Module

7. Head Mounts

8. Regulator/Filter Assembly

9. Air Lines

10. Reject Solenoid

11. Reject Device

12. Safety Guards

13. Moveable Guards

14. Guard mounting hardware

15. Controls

16. Safety Circuit

17. Electrical Cabinet

18. Labels

19. Cables

20. Firmware Version

Perform Metal Detection PV Certification and Calibration as described by manufacturer.

Power Phase Pro/V4/GF/300/800/Stainless/Y Valve

DIV Location Brand Warranty requires certified tech for repair Description of Equipment

QTY

Barcode
or ID No.Preventative MaintenanceModel Numbers

MES B123 LVD North America No Strippit punch press 1 39566 B-Annually:

- Remove cover from hydraulic unit and blow dust away from radiator

- Grease the following with Shell Alvania #EP2, 2 strokes with the grease gun:

X & Y Ballnuts, X-axis Carriage linear bearings, Y-axis carriage linear bearings, Workclamp X-axis linear bearings, Turret drive pillow block bearings.

- Great the ball screw end bearings with Mobilith XHP, 2 strokes with the grease gun.

- Inspect hydraulic oil in hydraulic unit, replace with Mobil Nuto H46 as necessary.

- Replace hydraulic oil filter, P/N 4219007-3ST-1212
MESB123HurcoNoCNC MILL136762Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
- OEM RecommendationsVM10i
MESB123HurcoNoCNC MILL137015Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
-OEM RecommendationsHTM30
MESB123HurcoNoCNC MILL137729Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
-OEM RecommendationsVMX42i
MESB123HurcoNoCNC MILL135192Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
-OEM RecommendationsVMX64Ti
MESB123HurcoNoCNC MILL132918Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
-OEM RecommendationsVMX24
MESB123HurcoNoCNC MILL132919Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
-OEM RecommendationsVMX24
MESB123HurcoNoCNC MILL134308Bi-Annually
-Grease the Automatic tool changer magazine chain assembly
-Grease the outriggers
-Verify the machine is sitting level
-Check ATC oil level
-Drain moisture from the lines of the FRL
-Replace coolant filters and CTS coolant filter
-Measure the ground impedance (resistance to true earth)
-Check the SR or SW hydraulic system oil level.
-OEM RecommendationsDCX22i
MESB123OMAXNoWaterjet127147Bi-Annually:
-Empty and clean garnet from the waterjet as well as the garnet bins.
-Change the water filter
- Replace any worn cutting nozzles, gartnet lines, or water lines if needed.55100
MESB123AKS Cutting SystemsNoWaterjet135184Bi-Annually:
-Empty and clean garnet from the waterjet as well as the garnet bins.
-Change the water filter
-Replace the electrical enclosure air filters.
- Replace any worn cutting nozzles, gartnet lines, or water lines if needed.WKX3-612
MESB123CincinnatiNoCNC Fiber Laser139273Bi- Annual:

- Remove the cover below the fume exhaust fan, and clean the duct.

- Remove all scrap trays and remove excess accumulation of fine particulate.

- Manually lubricate the fume fan assembly.

- Inspect the X-axis and Y-axis linear bearings and the magnet track protective cover for indications of wear or contamination. Clean and lubricate the linear rails as required. Inspect the linear moto assemblies for coolant leaks or indications of heat build-up. Inspect the area between the X-axis linear bearings and the encoders for debris and contamination.

- Lubricate the Z-axis linear bearings and ball screw.

- Replace the filter element (C.I. #914083) for the chiller water inpute.

- Clean the chiller condenser.

- Inspect the pallet drive chains and cables. Re-tensioin as necessary. Lubricate the pallet drive chains and gear reducers. Clean the pall guide rails.

- Inspect the machine for coolant leaks and oil leaks.

- Replace all missing or damaged safety signs.

- Test all coolant and laser amin voltage interlocks for proper operation.

- remove the bellows to expose the magnet tracks of the X1 and X2 axis linear motors. Dampen a cloth with isopopyl alochol and clean the tape that covers the magnet tracks. Re-lubricate the tape surface with a very light coating of synthetic grease (C.I #922230), then reinstall the bellows.

CL-900
MESB123CincinnatiNoShear137904Bi-Annual:

- Check machine level - relevel if necessary

- Check entire machine for loose fasteners

- Check knife and ram gib cleareance - adjust if necessary

- Check knife bolts and alignment adjustment nuts - tighten if necessary

- Check material control

- Check length control

- Replace return line filter cartidge

- Check oil temperature in reservoir - adjust temp control if necessary

- Grease backgage pivot blocks and lift cylinder clevises.

- Grease cylinder spherical bearings

- Check for water in hydraulic reservoir

- Check hydraulic reservoir level - add oil if necessary500HS10
MESB123Time SaversNoFinishing machine135334Bi-Annually:

- Grease/oil these components: Idler roll guide post, Brush heads (Oscillation linkage bearings), drive roll bearings, take-up roll bearings, support roll bearings, sanding heads, vacuum blower, feed drive motor, conveyor bed lift reducer and any other necessary components.

- Check conveyor belt and V-belts. Tighten if required.

- Check rubber covered rolls for any wear, delamination, or grooving.

- Check air pressure setting of each sandin head to detrermine that the abrasive belt is tensioned properly.LYNX 37MWT-D-60
MESB123PeerlessNoHorizontal saw130335Bi-Annually:

- Clean the filters in the cutting fluid tank

- replace the transmission oil

- Grease the drive wheel, idler wheel, blade tension device, and worm shaft

- check the hydraulic fluid.SHB-1120NC
MESB123DoALLNoVertical bandsaw19584Bi-Annually
-Lubricate saw column pivot point
-Inspect and adjust blade guides
-Check band wheel bearings
-Check the band guides
-Check the drives, visually inspect bearings and seals, check gears for excessive play, check pulleys for proper alignment
-Check the drive belt and the chip brush belt for cracks, wear, or stretchingV26
MESB123DoALLNoVertical bandsaw122566Bi-Annually
-Change hydraulic fluid filters
-Clan hydraulic fluid reservoir magnetic plug
-Lubricate saw column pivot point
-Inspect and adjust blade guides
-Check band wheel bearings
-Check the band guides
-Check the drives, visually inspect bearings and seals, check gears for excessive play, check pulleys for proper alignment
-Check the drive belt and the chip brush belt for cracks, wear, or stretching2612-H
MESB123BehringerNoCircular Saw137856B-Annually:

-Grease ball screw spindle and supply unit slide. Check visually and clean as well.

- Check all hydraulic lines and cylinders for damage or leaks.VMS 400H
MESB123MarvelNoVertical saw135767Bi-Annually:

- Clean the guide arm

- Check blade brush for wear

- Check oil level in tank -Check high pressure filter -Inspect/adjust blade guides -Lubricate chain

-Inspect for defects8 Mark III
MESB123Full Spectrum Laser TechnologyNoLaser cutting machine139567Bi-Annual:

- Check rail lubrication

- Change water in the cooling system

- Check the fume extractor filters

- Check for wear on belts

-Clean/Replace fume extractor filtersPS48
MESB123Kent corporationNoBurr master Tube Deburring machine139562Bi-Annual:

- Grease brush shafter bearings (4 places) with No. 2 consistency lithuim-base grease - recommendation

- Grease Conveyour shaft bearings (2 places) with No. 2 consistency lithuim-base grease - recommendation

- Grease sliding brush bearings (2 places) with No. 2 consistency lithuim-base grease - recommendation

- Change the oil in the conveyor drive box by OEM recommendations -Clean machine -Inspect chains

BM05-40
MESB123Wisconsin Oven CorporationNoHeat treat oven138575Bi-Annual:

- Clean and inspect air flow switches

- Clean and inspect burner

- Clean and inspect blower and wheel

- Clean and inspect exhaust blower

- Clean/inspect or replace filters

- Inspect Belt and drive

- Inspect door gasket

- Inspect door hinges

- Inspect ductwork

- Inspect for warpage and leaks

- Inspect all gas fittings and tighten as necessary

- Inspect all fasteners and tighten as necessary

- Grease motors and bearings

- No re-lubrication bearings should be checked for cracking or other signs of failures.

PERFORM SAFETY INTERLOCKS:

- Circulation Air Flow

- Combustion Air Flow

- Low Gas pressure

- Excess temp operation

- Process Timer

- Exhaust Air FLow

- Hi gas pressure

- Flame safe guard

- Purge Timer

- Limit Switch

Record Amp Draws for: Circulation, Exhaust, and Combustion.BATCH-4/8/3-12G/PWRD L
MESB123Cress Manufacturing CompanyNoElectric Furnace130373Bi-Annual:

- Regrease fan shaft bearings (located behind the chamber) with high temperature (lithium) grease.

- Check for open circuit by current or resistance type measurements, check elements visuualy for any damage. Replace if needed.

- Check door limit switch.C163212DSD4 HLCU L
MESB123FanucNoRobotic Welder136885
(F205369)Bi- Annual:

- Check for external damage or peeling paint

- Check for damages of the cable protective sleeves

- Check for water

- Check the mechanical cable and welding power cable (damaged or twisted)

- Check the end effector (hand cable)

- Check the motor cable for loosening.

- Tighten the end effector bolt

- Tight the cover and main bolt

- Check the fixed mechanical stopper and the adjustable mechanical stopper

- Remove spatter, dust, etc.

- Check the oil sight glass of J4 to J6 axis

- Check if fluoric resin ring is broken

- Check the robot cable, teach pendant cable, and robot connecting cable

- Clean the controller ventilation system M-10iD/12 variant on the R-30iB Plus A-Cab Controller and Lincoln Welder R450 power wave MES B123 Monarch No Conventional Lathe 1 36362 Bi-Annual:

- Drain and flush apron reservoir filling point and oil level gauge

- Grease taper attachement if in use

- Oil traveling rod supports

- Grease apron control rod bearings612
MESB123OkamotoNoSurface grinder135361Bi-Annual:

- Clean the strainer

- Grease and clean the guide ways

-Clean machine618-B
MESB123MonarchNoConventional Lathe134041Bi-Annual:

- Drain and flush apron reservoir filling point and oil level gauge

- Grease taper attachement if in use

- Oil traveling rod supports

- Grease apron control rod bearingsEE4950
MESB123SBLNoPower press19989Bi-Annual:

- Grease the flywheel bearings, bull gear bearings, and backshaft bearings.

- Check clearance on flywheel bearings

- Inspect friction discs for wear and cleanliness, hub & center plate splines spray splines with silicone.

- Check brake linings

- check brake shoes, air cylinder and plunger for casting cracks, signs of wear

- Clean air oiler and filter

- Check air gages for accuracy

- Inspect control box and palm button contacts

- inspect rotary limit switch, chain, and sprockets.

- Inspect V Belts for wear

- Check motor bearings

- Check flywheel bearings

- Check Gib adjustment

- Check drive gears and keys for looseness

- check bronze bearings for excessive wear or loosness

- Inspect cylinders for wear and loose parts

- Check press level, die cushion, and knockout bracket adjustment

OB-127
MESB123SBLNoPower press19990Bi-Annual:

- Grease the flywheel bearings, bull gear bearings, and backshaft bearings.

- Check clearance on flywheel bearings

- Inspect friction discs for wear and cleanliness, hub & center plate splines spray splines with silicone.

- Check brake linings

- check brake shoes, air cylinder and plunger for casting cracks, signs of wear

- Clean air oiler and filter

- Check air gages for accuracy

- Inspect control box and palm button contacts

- inspect rotary limit switch, chain, and sprockets.

- Inspect V Belts for wear

- Check motor bearings

- Check flywheel bearings

- Check Gib adjustment

- Check drive gears and keys for looseness

- check bronze bearings for excessive wear or loosness

- Inspect cylinders for wear and loose parts

- Check press level, die cushion, and knockout bracket adjustment60 BG
MESB123DoALLNoSurface grinder18184Bi-Annual:

- Clean the strainer

- Grease and clean the guide ways

-Clean machineD1030-14
MESB123SBLNoSurface grinder118668Bi-Annual:

- Clean the strainer

- Grease and clean the guide ways

-Clean machineFSG-612
MEDB165VideojetYesInkjet Printer1TBDSemi-Annual PM (based on PM requirements from OEM)1710

PM - Annual

Crane Army Ammunition Activity
Maintenance and Repair of Manufacturing Equipment and Systems Used in Explosive and Non-Explosive Operational Environments
Annual Preventative Maintenance List
DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MECB136Pacific MagneformNoMagneformer1TBDAnnual Inspections

Perform the following inspections annually:

a) Check door and panel gaskets.

b) Check electrical connections for loose or broken wires.

c) Inspect high-voltage bus for loose connections and dust buildup.

d) Inspect inside local control and high-voltage compartments for dust buildup, loose or distressed components, and general condition of components.

Special Inspections

High-Current Conductor Connection Inspections. Magnetic pressure may loosen some of the screws or bolts holding the bus work, cable clamps, or ignitron switches, and may create a situation where arcing occurs. After every 30,000 cycles, the following equipment should be inspected for loose bolts and screws, etc:

a)Capacitor bus work
b)Cable clamps
c)Ignitron holders.7000 16KJ
MECB145FanucNoRobomill232775, 36763Check and Clean all Air/Fan Filter, Replace or clean if contaminated

Check Fan Motors for Excess Wear or Damage, the ones that exchange Outside Air into Cabinets Replace all Fluids if applicable Perform modified Ball Bar Test of X,Y,Z Axis, Document (at MEC descretion) Check, Clean and Lubricate Tool Changer Change CNC Control Back-up Batteries (4 D-cells) Check Tram of Spindle to Table, Document Check and Clean Safety Interlocks Check Machine Lubricant Grease/Oil, Change Grease Cartridge or Top off Resevior, Replace Way Oil if Contaminated Remove and Inspect Axis Covers and Wipers, clean any debris Clean and Inspect Liners Guides and Ways Monitor Servo and Spindle Motor Current Draw, Document Check Electrical Cabinet, Clean Interior Check for Loose or Damaged Wire Connections Check all External Cables Wires and Hoses for Damage Check Machine Level, Document Visually Inspect Outside of Machine and report any abnormalities or Safety Concerns Check Files for Error Messages that need attention Clear all Clocks Check and Clean all Limit Switches

Replace lithium battery in control panel of doorT14iF and D14MiB5
MECB200FanucNoRobomill132806Check and Clean all Air/Fan Filter, Replace or clean if contaminated

Check Fan Motors for Excess Wear or Damage, the ones that exchange Outside Air into Cabinets Replace all Fluids if applicable Perform Ball Bar Test of X,Y,Z Axis, Document (at MEC descretion) Check, Clean and Lubricate Tool Changer Change CNC Control Back-up Batteries (4 D-cells) Check Tram of Spindle to Table, Document Check and Clean Safety Interlocks Check Machine Lubricant Grease/Oil, Change Grease Cartridge or Top off Resevior, Replace Way Oil if Contaminated Remove and Inspect Axis Covers and Wipers, clean any debris Clean and Inspect Liners Guides and Ways Monitor Servo and Spindle Motor Current Draw, Document Check Electrical Cabinet, Clean Interior Check for Loose or Damaged Wire Connections Check all External Cables Wires and Hoses for Damage Check Machine Level, Document Visually Inspect Outside of Machine and report any abnormalities or Safety Concerns Check Files for Error Messages that need attention Clear all Clocks Check and Clean all Limit Switches

Replace Lithium battery in control panel of doorD14MiB5
MECB2520FanucNoRobomill137865Check and Clean all Air/Fan Filter, Replace or clean if contaminated

Check Fan Motors for Excess Wear or Damage, the ones that exchange Outside Air into Cabinets Replace all Fluids if applicable Perform Ball Bar Test of X,Y,Z Axis, Document (at MEC descretion) Check, Clean and Lubricate Tool Changer Change CNC Control Back-up Batteries (4 D-Cells) Check Tram of Spindle to Table, Document Check and Clean Safety Interlocks Check Machine Lubricant Grease/Oil, Change Grease Cartridge or Top off Resevior, Replace Way Oil if Contaminated Remove and Inspect Axis Covers and Wipers, clean any debris Clean and Inspect Liners Guides and Ways Monitor Servo and Spindle Motor Current Draw, Document Check Electrical Cabinet, Clean Interior Check for Loose or Damaged Wire Connections Check all External Cables Wires and Hoses for Damage Check Machine Level, Document Visually Inspect Outside of Machine and report any abnormalities or Safety Concerns Check Files for Error Messages that need attention Clear all Clocks Check and Clean all Limit Switches Replace lithium battery in control panel of door D14MiB5

DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MEPB2697Maxwell LaboratoriesNoMagneformer1W39ZAA08463Annual Inspections

Perform the following inspections annually:

a) Check door and panel gaskets.

b) Check electrical connections for loose or broken wires.

c) Inspect high-voltage bus for loose connections and dust buildup.

d) Inspect inside local control and high-voltage compartments for dust buildup, loose or distressed components, and general condition of components.

Special Inspections

High-Current Conductor Connection Inspections. Magnetic pressure may loosen some of the screws or bolts holding the bus work, cable clamps, or ignitron switches, and may create a situation where arcing occurs. After every 30,000 cycles, the following equipment should be inspected for loose bolts and screws, etc:

a)Capacitor bus work
b)Cable clamps
c)Ignitron holders.7000 16KJ
DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MEDB138Fryer Easy TurnNoLathe137797a) Replace oil filter
b) Clean the ChuckET-25
MEDB138FanucNoRobot137796Annual PM based on OEM recommendations1704202
DIVLocationBrandWarranty requires certified tech for repairDescription of EquipmentQuantityBarcode / ID No.Preventative MaintenanceModel Numbers
MEOB155ABBNoWaterjet Robot1320161. Inspect gear oil level in each AXIS 1-6. Fill as required

2. Every 48-months, replace gear oil in each AXIS 1-6.

3. Inspect Mechancial Stop, Axis 1-3. Repair/replace if necessary

4. Inspect Position switches, Axis 1-3. Repair/replace if necessary

5. Inpsect Manipulator Harness, Cabling for postion switch and fan, balancing device and gearbox. Repair/replace if necessary.

6. Inspect and clean controller cabinet. Replace cabinet air filters. Repair/replace damaged or failed parts/components

7. Perform Service Assessment S4CPLUS M2000

DIV Location Brand Warranty requires certified tech for repair Description of Equipment

QTY

Barcode
or ID No.Preventative MaintenanceModel Numbers
MESB123DoosanNoCNC LATHE135696Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary
-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.
-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLynx 220LSY
MESB123OkumaNoCNC LATHE139584Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary

-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.

-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLU4000 EX
MESB123OkumaNoCNC LATHE139585Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary
-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.
-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLU4000 EX
MESB123OkumaNoCNC LATHE137895Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary
-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.
-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLB3000 EX II
MESB123OkumaNoCNC LATHE137896Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary
-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.
-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLB3000 EX II
MESB123OkumaNoCNC LATHE137897Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary
-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.
-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLB3000 EX II
MESB123OkumaNoCNC LATHE129178Annually:
-Have the headstock checked for taper
-Have the spindle checked for radial and end play
-Have the chuck cylinder checked for run out
-Have the tailstock checked for taper
-Have the turret parallelism and inclination checked
-Run a backlash program to check the backlash in X- and Z-axis and adjust if necessary
-Check the X- and Z-axis gibs and adjust if necessary
-Have the hydraulic tank drained and replace the hydraulic oil and also have the line filter and suction filter charged.
-Have the radiator cleaned and make sure radiator fins are straight
-Have the lubrication unit drained and cleaned out then add fresh way lube.
-Have the cooling unit (if applicable) drained and refilled
-Check the leveling of the machine and adjust if necessary
-Have all way wipers inspected for any damage, replace and clean if necessary.
-Grease the chain on the chip conveyor
-Check and clean the filters on the coolant tank
-Any other OEM recommendationsLU400
MESB123LVD North AmericaNoStrippit punch press139566Annually:
- Replace batteries for absolute encoders, four (4) D-Cell alkaline batteries. Batteries must be replaces with control power on and in E-stop to maintain reference.ST-1212
MESB123HurcoNoCNC MILL136762Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
-Any other OEM recommendationsVM10i
MESB123HurcoNoCNC MILL137015Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
-Any other OEM recommendationsHTM30
MESB123HurcoNoCNC MILL137729Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
Any other OEM recommenationsVMX42i
MESB123HurcoNoCNC MILL135192Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
-Any other OEM recommendationsVMX64Ti
MESB123HurcoNoCNC MILL132918Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
-Any other OEM recommendationsVMX24
MESB123HurcoNoCNC MILL132919Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
-Any other OEM recommendationsVMX24
MESB123HurcoNoCNC MILL134308Annually:
-Clean auto lube reservoir tank and suction filter
-Disassemble and grease the tool changer unit at intervals of approximately one million tool changes
-Replace Automatic tool changer oil
-Flush, clean, and refill the spindle chiller tank
-Replace the oil for the SR or SW tilt mechanism
-Replace the SR or SW hydraulic oil
-Replace the rotary-axis oil
-Replace the tilt-axis oil
-Any other OEM recommendationsDCX22i
MESB123OMAXNoWaterjet127147Annually:
-Change the crank case oil
-Inspect the filter housing O-ring
-Inspect and replace individual slats
-Lubricate the X- and Y-axis lead screws and linear rails55100
MESB123AKS Cutting SystemsNoWaterjet135184Annually:
-Change the crank case oil
-Inspect the filter housing O-ring
-Inspect and replace individual slats
-Lubricate the X- and Y-axis lead screws and linear rails

Hydraulic system

- Lubricate motor bearings with SRI #2 bearing grease

- Fill the pump case with oil, check for leaks Recirculation system

- Anylayze hydraulic oil, replace if necessary.

- Check oil level and temperature. Check filter, replace if needed.

Electrical

- Check for any fault messages

- Check control panel lights for proper operationWKX3-612
MESB123KMT WaterjetNoWaterjet intensifier127765Annually:

Hydraulic system

- Lubricate motor bearings with SRI #2 bearing grease

- Fill the pump case with oil, check for leaks Recirculation system

- Anylayze hydraulic oil, replace if necessary.

- Check oil level and temperature. Check filter, replace if needed.

Electrical

- Check for any fault messages

- Check control panel lights for proper operationSL-IV 50
MESB123LASER: Cincinnati Inc
Dust coll: Camfil APCNoCNC Fiber Laser139273Annual:
-Lubricate the X, Y, and Z-axes as stated:

X-Axis: Grease by using the grease manifolds for the linear bearings, accessed by removed metal cover on the side of the gantry. Repeat for the opposite side. (6 fittings) Y-Axis: Grease by pulling back the Y-axis cover. There are two fittings on both side of the Y-plate. (4 fittings) Z-Axis: Grease both of the truck bearings (2 fittings) on the Z-axis.

Z-Axis ball screw: 1 fitting

-Replace the bulbs in the laser status indicators on top of the laser generating unit and the safety enclosure
-Check the concentration of the chiller fluid additives. Purge and refill if needed.
-Replace assist gas filter cartridges

DUST COLLECTION SYSTEM:

- Check inlet baffle for wear

- Inspect filter cartridges thoroughly

- Check ducts for material build-up

- Inspect paint, insulation, ect. for corrosion

- Check fan belts tension and wear

- Check Airlock/ screw conveyor for general wear

- Record pulse duration/delay

- Perform Bag dye penetrant test.

- Check all hardware connections and visible welds

- Check door gaskets, check for any leaks in the fittings or air lines.

- Check Diaphragm vales for proper operation

- Inspect for any corrosion on the fans, housing

- Inspect and lubricate andy fittings or appropriate items.

- Check for accuracy of indicaton equipment CL-900 Gold Series X Flo MES B123 Cincinnati No Shear 1 37904 Annually:

- Check hydraulic pressures - adjust if necessary

- Check accumulator precharge pressure and recharge if necessary

- Clean intake strainer or replace

- Drain, clean, and refill hydraulic reservoir. Use 10 micron filter when filling.500HS10
MESB123AccupressNoPress brake125253Annually:

- Grease all lubrication points (Suggested Pennzoil EP Grease 704):

Lower rod bearings Press ram/bed parallel adjustment mechanism Manual backgauge

- Replace and Fill hydraulic fluid in the reservoir

- Replace the return line filter

740010
MESB123Time SaversNoFinishing machine135334Annually:

- Examine batteries, replace if needed.

- Repalce brake pads if needed

LYNX 37MWT-D-60
MESB123Auto-Sert, IncNoHydraulic press124845Annually:

- Refill hydraulic fluid if needed. Takes 12 gallons of Mobil DTE 26 or equivalent.

- Remove and replace hydraulic filter, P#800876AS-7.5
MESB123DoALLNoVertical bandsaw19584Annually:
-Change transmission oilV26
MESB123DoALLNoVertical bandsaw122566Annually
-Drain and change hydraulic fluid
-Clean hydraulic fluid strainer and fluid filter
-Change transmission oil2612-H
MESB123BehringerNoCircular Saw137856Annually:

- Change/fill the following with OEM recommend lubricants:

Gear box Auxiliary gear Coolant tank Hydraulic oil tank

- change the return filter insert

- change the filter control block saw feed regulator insert

- replace belt, tooth belth, or v-ribbed belts.

- Replace batteries in control panel

- replace pressure filter

- Replace all electrical connectors such as electric plugs, input and out modules, Hyrdo or PV fittings for tightness.VMS 400H
MESB123MarvelNoVertical saw135767Annually
-Drain and change hydraulic fluid
-Clean hydraulic fluid strainer and fluid filter8 Mark III
MESB123Kent CorporationNoBurr Master Tube Deburring Machine139562Annual:
- Grease the brush motorBM05-40
MESB123Wisconsin Oven CorporationNoHeat treat oven138575Annual:
- Completely replace gear oil every 10,000 hours.BATCH-4/8/3-12G/PWRD L
MESB123Cress Manufacturing CompanyNoElectric furnace130373Annual:

- Clean front and rear ventilation ports and louvers

- Clean interior of control panel if dirty, replace any instrumentation if needed.

- Remove any spills or deposits from the chamber walls

- Inspect condition of fan belt and tension, replace if cracked or worn.

- Inspect door seal.

- Replace the thermocouples.C163212DSD4 HLCU L
MESB123Thermo FisherNoFurnace box137412Annual:

- Clean front and rear ventilation ports and louvers

- Clean interior of control panel if dirty, replace any instrumentation if needed.

- Remove any spills or deposits from the chamber walls

- Inspect condition of fan belt and tension, replace if cracked or worn.

- Inspect door seal.

- Replace the thermocouples.CC58114PC
MESB123TsuneNoCircular saw137868Annual:

- Adjust the saw drive timing belt tension

- Tighten any look screws or bolts

- Check If there is any air leakage from the pneumatic equipment or piping joints.

- Replace gear oil (at saw head)

- Ensure lubrication system is properly working.TKA50
MESB123TsuneNoCircular Saw134161Annual:

- Check for loose screws and bolts -Check for oil leakage from piping joints and hydraulic equipment

- Replace hydraulic oil

- Replace gear oil (at saw head)

- Apply oil to the saw slide

- Grease the saw slide ball screw

- Check and fill mist liquid reservior

- Adjust the V-Belt tension.TK5C-1600GL
MESB123Fanuc / Lincoln electricNoRobotic Welder136885
(F205369)Annually:

- Replace the mechanical unit batteries

- Replace controller batteries (if needed)

- Check for external damage or peeling paint

- Check for damages of the cable protective sleeves

- Check for water

- Check the mechanical cable and welding power cable (damaged or twisted)

- Check the end effector (hand cable)

- Check the motor cable for loosening.

- Tighten the end effector bolt

- Tight the cover and main bolt

- Check the fixed mechanical stopper and the adjustable mechanical stopper

- Remove spatter, dust, etc.

- Check the oil sight glass of J4 to J6 axis

- Check if fluoric resin ring is broken

- Check the robot cable, teach pendant cable, and robot connecting cable

- Clean the controller ventilation system

- Inspect mechanical unit welding power cable, replace if needed

- Inspect material handling conduit, replace if needed

- Check/ inspect to see if oil and grease needs to be replaced in these drive mechanisms:

If needed to be replaced, use the following:
- J1 Axis reducer, grease spec: A98L-0040-0174, 870ml

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .