About this file

This document appears to be a set of drawings related to a federal contract opportunity for the USGS Hydrologic Instrumentation Facility (HIF) in Tuscaloosa, AL. The drawings provide detailed layouts and specifications for a sensor innovation lab, dirty shop, paint booth, welding area, and related equipment and utilities.

The associated federal contract opportunity, Solicitation Number 140G0124Q0289, is for the delivery and installation of transformers and related services at the HIF facility, to be awarded as a small business set-aside contract. The RFQ will be issued on or about 8/30/2024, with quotes due by 09/05/2024. The anticipated award date is 09/15/2024. The NAICS code is 335311, with a size standard of 800 employees. Interested vendors must be registered in SAM.gov to be considered for the contract.

View the file

Other files

File Type Posted
Sol_140G0124Q0289_Amd_0001.pdf PDF
B08_ATCH_1_SOW.pdf PDF
Sol_140G0124Q0289.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

13 14 15 16

B

D

E

LS

-1

S 34"

H/C

22 3

QC004

QC004

QC003

QC003

PT

D

-A

B.5

QL4531

QL453 3

FM

FM025

FM

FM

PR2

PT

D

-A

FM006

FM011

FM

FM

FM023

PT

D

-A PR2

SENSOR

INNOVATION

PAINT BOOTH

OFFICE

QA HOLDING

WELDING

AREA

QL503 5

QL503

4'

WE NEED TO DOCUMENT

THIS PAINT BOOTH - MFR

SHOULD PROVIDE EXH FAN,

CONTROLLER, AND THE

MAKE-UP AIR UNIT...

*** UPDATE IN SPECS ***

need a keyed note; need equipment spec for it

FM024

8'

2'

1"

12 22

FM018

FM019

FM022

HAAS

ST-25

CNCHAAS

VF3

CNC

LARGE

SURFACE

TABLE

FM002

FM010

FM004

FM005

FM

FM012

GORTON

HORZ

/VERT

MILL

VERT

BAND

SAW

MEDIUM

LATHE

LARGE

LATHE

HYD

PRESS

DRILL

PRESS

FM027

ARBOR

PRESS

SHAVINGS BINS

DUCTED EXHAUST

CONNECTIONS

PLAN DUCTED EXHAUST

LT

-0

LT

-0

LT

-0

LT

-0

LT

-0

LT-04

QL45311 QL453 11

QL453 11

QL453 11

QL453

CORD REEL 120VCORD REEL 120VCORD REEL 120V

CORD REEL 120V

CORD REEL120V

EQUIP POWER

FROM OVERHEAD

208V 3PH 20A

EQUIP POWER

FROM OVERHEAD

120V 3AMP

220V 3PH 2.5HP

208V 3PH 20A

440V 3PH

440V 3PH

NOT ALL KEYED NOTES ARE USED.

1. TEACHING WALL, SEE ARCH AND AV.

2. MARINE EDGE.

3. STAINLESS STEEL CASEWORK - 316L GRADE.

4. COUNTERTOP GROMMET.

5. EXHAUST CONNECTION AT CORROSIVES CABINET, SEE MECH.

6. MAINTENANCE/SERVICE ACCESS HATCH THROUGH CEILING

PANEL, BY CER MFR.

7. GLASS MARKER BOARDS ON STAND-OFF MOUNTS. SEE ARCH.

8. FLOOR DRAIN FOR CER CONDENSATE, SEE PLUMB.

9. WALL MOUNTED CONTROL PANEL FOR CER.

10. ELEC & DATA CONNECTIONS IN FLOOR, SEE ELEC.

11. SERVICE FITTINGS MUST BE WITHIN ACCESSIBLE REACH, 24" MAX.

12. EQUIPMENT FURNISHED AND INSTALLED BY CONTRACTOR (CFCI).

13. PROVIDE STAINLESS STEEL SIDE SPLASH / UMBILICAL CURB END CAP AT

UM-A LOCATIONS. FINISH TO MATCH COUNTERTOPS, SEE 1 / QL504

14. CHARGING STATION(S) FOR LIFTS, SEE ELEC.

15. SEAL JOINT BETWEEN DISSIMILAR COUNTERTOP MATERIALS

16. ALIGN, SEE DASHED LINES AND DIMENSION REFERENCES.

17. COUNTERTOP WITH "WATERFALL" EDGE, SEE DETAIL 10/QL501

18. CENTER

19. CASEWORK MFR / VENDOR TO REVIEW DESIGN FOR LOAD

CAPACITY. CONFIRM DESIGN WILL SUPPORT OFOI WATER TANK

WEIGHING UP TO 2,500 LBS PLACED ON COUNTERTOP. NOTIFY

ARCHITECT IF DESIGN CHANGE IS REQUIRED.

20. CARRIAGE / WORK PLATFORM WITH GUARD RAILS. TRACKS / RAILS

MOUNTED TO TANK SIDEWALLS. SHOWN FOR REFERENCE ONLY,

SELECTED VENDOR TO DETAIL SPECIFIC REQUIREMENTS.

21. STAINLESS STEEL SINK WITH PRE-RINSE FAUCET, SEE PLUMB.

22. PAINT BOOTH WITH APPROX. 6'W X 6'D X 8'H CHAMBER. SELECTED MODEL

MUST BE DESIGNED FOR INSTALL WITHOUT SIDE OR REAR CLEARANCES

AS SHOWN. SELECTION TO BE COORDINATED WITH MAKE UP AIR SYSTEM

AND CONTROLS, SEE MECH AND ELEC. SEE SPECIFIC NOTES ON M101B

AND M703.

SHOWN

LABORATORY FURNISHINGS AND EQUIP KEYED NOTES

NO. REVISIONS DSGN CHKD APVD DATE

DESIGNED

DRAWN

CHECKED

APPROVED

APPROVED

DATE

SCALE:

NO. REV.

A

B

C

D

E

F

G

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10 11

1 2 3 4 5 6 7 8 9 10 11

STANLEY CONSULTANTSC

C

AD

D D

3- R

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

AT FULL SIZE

1 2 3 IN

1 2 3 4 5 6 7 8 cm

FINAL CONSTRUCTION DOCUMENTS

PROPERTY OF THE UNITED STATES GOVERNMENT

COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS,

PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED.

Do not remove this notice. Properly destroy documents when no longer needed.

1/4" = 1'-0"

USGS

HYDROLOGIC INSTRUMENTATION FACILITY (HIF)

TUSCALOOSA, AL

Project Number

QL404

JHL

RBU

MPW

3/29/2023

USGS

HYDROLOGIC INSTRUMENTATION FACILITY (HIF)

TUSCALOOSA, AL

ENLARGED PLAN - SENSOR

INNOVATION LAB

1/4" = 1'-0"1 ENLARGED PLAN - DIRTY SHOP, PAINT BOOTH / HAZ MAT, & WELDING

0 ISSUED FOR CONSTRUCTION (IFC)

3 ITC 0020

FEB 07, 2022

MAR 29, 2023

fshenry Rectangle fshenry Rectangle fshenry Typewritten Text Vertical Mill fshenry Typewritten Text Lathe

File details come from the government source that posted it. Updated .