B08_24R0036_Attachment_2_-_Drawings.pdf

PDF 14 MB Posted

Attached to
FAIRBANKS DISTRICT OFFICE ROOF REPLACEMENT
Solicitation number
140L0624R0036
Issued by

About this file

The provided document is Attachment 2 - Drawings for the Solicitation Number 140L0624R0036 for the BLM Fairbanks District Office Roof Replacement project.

This solicitation is for all labor, materials, equipment, and supervision required to replace the roof on the BLM Fairbanks District Office located at 222 University Avenue, Fairbanks, Alaska. The work includes complete construction of the roof assembly and all related mobilization and demobilization efforts. This attachment contains the drawings that provide technical specifications and details for the required roof replacement work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 View Name 1/8" = 1'-0"A101

Room name

GENERAL SYMBOLS

NAME

NUMBER

SHEET LOCATION

SCALE

TRUE NORTH

GRID LINE

ROOM NAME

ROOM NUMBER

PLAN NORTH

REVISION

SEE DISCIPLINES FOR SPECIFIC SYMBOLS

PROJECT TEAM

OWNERS REPRESENTATIVE

BUREAU OF LAND MANAGEMENT

POINT OF CONTACT: CURT FORTENBERRY

222 UNIVERSITY AVE

FAIRBANKS, ALASKA 99709

907 474-2206

CFORTENB@BLM.GOV

DESIGNERS REPRESENTATIVE

DESIGN ALASKA

POINT OF CONTACT: JAMES BARTLETT

601 COLLEGE ROAD

FAIRBANKS, ALASKA 99701

907 452-1241

JAMESB@DESIGNALASKA.COM

ALASKA MAP

PACIFIC OCEAN

ARCTIC OCEAN

BERING

SEA

KODIAK

ARCTIC CIRCLE

SEWARD

SITKA

JUNEAU

HAINES

WHITEHORSE YT

DAWSON YT

HAINES

JCT

HOMER

ANCHORAGE

EAGLE

CORDOVA

VALDEZ

GLENNALLEN

TOK

NORTH

POLE

FAIRBANKS

NENANA

TANANA CIRCLE

NOME

KOTZEBUE

UTQIAGVIK

(BARROW)

PRUDHOE BAY

U N

IT

ED

S

TA

TE

S

R U

SS

IA U

N

ITED

STATES

C

AN

AD

A

PROJECT

LOCATION

CODE INFORMATION

GOVERNING CODES

INTERNATIONAL BUILDING CODE (IBC) 2012

INTERNATIONAL FIRE CODE (IFC) 2012

INTERNATIONAL MECHANICAL CODE (IMC) 2012

NATIONAL ELECTRICAL CODE (NEC) 2017

AUTHORITY HAVING JURISDICTION

BUREAU OF LAND MANAGEMENT

CODE SUMMARY

OCCUPANCY TYPE : GROUP B, NO CHANGE OF OCCUPANCY

ROOF REPLACEMENT: ALTERATIONS LEVEL 1

U N

IV

ER

SI

TY

A

VE

N U

E

CONTRACTOR ROOF ACCESSCONTRACTOR

STAGING AREA

VICINITY MAP

PROJECT

LOCATION

CH

EN

A

RI

VE

R

U N

IV

ER

SI

TY

A

VE

N U

E

AIRPORT WAY

BOAT STREET

SPORTSMAN W

AY

GERAGHTY AVENUE

CHENA RIVER

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 4:03:46 PM

GENERAL

INFORMATION

G001

FAIRBANKS DISTRICT OFFICE

ROOF REPLACEMENT

FAIRBANKS, ALASKA

BUREAU OF LAND MANAGEMENT

ARCHITECTURAL

A001 ARCHITECTURAL INFORMATION

A100 DEMOLITION PLAN - PENTHOUSE AND ROOF

A200 RENOVATION PLAN - PENTHOUSE AND ROOF

A500 EXTERIOR DETAIL - ASSEMBLY TYPE

A510 EXTERIOR DETAIL - TYPICAL

A620 INTERIOR PLAN - CEILING - 2ND FLOOR

GENERAL

G001 GENERAL INFORMATION

SHEET INDEX

ELECTRICAL

E001 ELECTRICAL SYMBOLS, LEGENDS AND DETAILS

E100 ELECTRICAL ROOF PLAN

MECHANICAL

M001 MECHANICAL ABBREVIATIONS, LEGENDS,

SCHEDULES, AND DETAILS

M100 LOWER ROOF PLUMBING DEMOLITION PLAN

M200 ROOF PLUMBING PLAN

CIVIL

C200 SITE PLAN

4" DOWNSPOUT

GRASS

CO

NC. SIDEW

ALK

CHAIN LINK FENCE

BLM BUILDING 2 STORY

BLOCK CONSTRUCTION

FRAME

SHOP

GRASS

GRAVEL PARKING LOT

DEMO APPROX. 200

SF CONC. SIDEWALK

SAWCUT CONC. AT

NEAREST JOINT

SWALE

LIGHT POST (TYP)

(E) 4" DOWNSPOUT

(E) GRASS

(E) CO

NC. SIDEW

ALK

(E) CHAIN LINK FENCE

(E) BLM BUILDING 2

STORY BLOCK

CONSTRUCTION

(E) FRAME

SHOP

(E) GRASS

(E) GRAVEL PARKING LOT

'-6

GRADE GRASS LINED

SWALE AT 2% FROM

BUILDING DOWNSPOUT

AND DRAIN TO EXISTING

SWALE

MATCH EXISTING CONC.

SIDEWALK ELEVATIONS

AND WIDTH

GRADE

BREAK

2%

2%

CONCRETE CULVERT

C200

SIDEWALK

C200

C200

RIP RAP 4' X 10'

(E) SWALE

TOPSOIL AND SEED

DISTURBED AREAS

(E) LIGHT POST (TYP)

C200

10'-0"

R2'-0"

12" MIN

ROUND

EDGES

6" MIN

9/17/2021 11:19 AM 902102 C200.DWG

902102

20 SEP 2021

COMM. NUMBER

ISSUE DATE

DESIGNED BY

DRAWN BY

1"0" SCALE

601 College Road Fairbanks AK 99701 907.452.1241

Architects SurveyorsEngineers

AECC511 designalaska.com

FDO ROOF

REPLACEMENT

C200

IAL

CCD

SITE PLAN

EXISTING CONDITIONS AND DEMOLITION PLAN1

C200 1" = 10'

SITE IMPROVEMENTS PLAN2

C200 1" = 10'

12"8"

EXISTING NEW

1/2" EXPANSION JOINT MATERIAL

1/2" DEEP SEALANT W/

1/4" RAD AT SURFACE

GREASE 12" DOWEL

SEGMENT PRIOR TO

POURING NEW CONCRETE

#4 SMOOTH DOWEL

CENTERED IN

SECTION. INSTALL

AT 18" O.C. IN SLABS.

SECURE DOWEL WITH EPOXY

IN DRILLED HOLE IN

ACCORDANCE WITH EPOXY

MANUFACTURER'S

RECOMMENDATIONS.

5'-9"

12" STRUCTURAL FILL 1

1. PROVIDE 1/2" EXPANSION JOINTS EVERY 24' AND

AT ANY CORNERS UNLESS OTHERWISE NOTED.

2. PROVIDE CONTROL JOINTS TO MATCH

CONCRETE WIDTH. MAINTAIN APPROXIMATELY

SQUARE SECTIONS, MAX DIMENSIONS TO BE 10',

OR AS DIRECTED.

NOTES

COMMON

FILL

COMMON

FILL

6x6 W2.1xW2.1 WWF 4" CONC. SIDEWALK.

SLOPE PER PLANS.

4" TOPSOIL

& SEED, TYP

INSITU

SOILS

EXISTING TO NEW CONCRETE3

C200 NO SCALE

SIDEWALK SECTION4

C200 NO SCALE

CONCRETE CULVERT5

C200 NO SCALE

5'-9"

2% MIN

4"

A

A

4" C

O N

C . S

ID

EW

AL

K, T

YP

12"

1TYP

4" TYP

#3 CONT, TYP

PROFILE VIEW

SECTION A-A

#3 @ 18" O.C.

EACH WAY

1/2" GALVANIZED ANGLE

HEADED ANCHOR

STUDS @ 12" O.C.

3/8" GALVANIZED STEEL

PLATE, NON SKID RAISED

SURFACE

12" STRUCTURAL FILL

GRADE AT 2% TO MATCH

EXISTING SWALE

COMMON FILL

RIP RAP SEE DETAIL

2/C200 FOR DIMENSIONS

6"

4"

D E S I G N

A L

A S

K A

Charles Cutter Degerlund

No. CE124811 17-Sep-2021

GRASS LINED SWALE6

C200 NO SCALE

CONCRETE

GYPSUM

RIGID INSULATION

MASONRY CONCRETE

PLYWOOD

MATERIAL LEGEND

BATT INSULATION

SPRAY FOAM INSULATION

EXISTING

CONSTRUCTION

NO ARCHITECTURAL WORK

THIS AREA

RIGID MINERAL FIBER

BATT/BLOWN INSULATION

TEMPORARY

CONSTRUCTION

EXISTING

CONSTRUCTION DETAIL

ARCHITECTURAL SYMBOL LEGEND

150 SF

Room Name

DETAIL NAME

DETAIL NUMBER

SHEET LOCATION

DETAIL SCALE

TRUE NORTH

GRID LINE

ROOM NAME

ROOM NUMBER

PLAN NORTH

DETAIL NUMBER

SHEET LOCATION

SIMILAR

REVISION

SPOT ELEVATION

SEE OTHER DISCIPLINES FOR ADDITIONAL SYMBOLS

KEYED NOTE

DOOR TAG

A100

A100

EXTERIOR ELEVATION

SHEET LOCATION

DETAIL NUMBER

INTERIOR ELEVATION

SHEET LOCATION

DETAIL NUMBER

DETAIL NUMBER 4

A

BUILDING SECTION

DETAIL NUMBER

SHEET LOCATION

SIMILAR

WALL SECTION

WINDOW TYPE

ROOM AREA

1/8" = 1'-0"A101 View Name

1/4" / 1'-0"

.SPOT SLOPE

101ROOM NUMBER

A101

SIM

A101

SIM

101A

1. SEE OTHER DISCIPLINES FOR ADDITIONAL ABBREVIATIONS.

2. SEE GENERAL SHEETS FOR CODE ABBREVIATIONS.

3. SEE ASSEMBLY TYPES FOR HYPHENATED ASSEMBLY TAGS

(I.E. C-A1, W01-3A, AND WX-3A).

4. SEE MATERIAL SCHEDULE FOR HYPHENATED MATERIAL TAGS

(I.E. ACT-1, CPT-1, AND RB-1).

5. SEE ROOM AND DOOR SCHEDULE FOR SPECIFIC RELEVANT

ABBREVIATIONS.

6. SOME ABBREVIATIONS LISTED BELOW MAY NOT BE USED IN

THIS PROJECT.

(E) EXISTING

ADA AMERICAN DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CFOI CONTRACTOR FURNISHED OWNER INSTALLED

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

ELEC ELECTRICAL

FV FIELD VERIFY

GA GYPSUM ASSOCIATION

GYP GYPSUM BOARD

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

ITSP INSULATED TRANSLUCENT SANDWICH PANEL

MAX MAXIMUM

MECH MECHANICAL

MFSD MANUFACTURER'S STANDARD

MIN MINIMUM

NIC NOT IN CONTRACT

OC ON CENTER

OD OVERFLOW DRAIN

OFOI OWNER FURNISHED OWNER INSTALLED

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OSB ORIENTED STRAND BOARD

OTS OPEN TO STRUCTURE

PLY PLYWOOD

RD ROOF DRAIN

SIP STRUCTURAL INSULATED PANEL

SPEC SPECIFICATION

STC SOUND TRANSMISSION CLASS

STRUC STRUCTURAL

TBD TO BE DETERMINED

TYP TYPICAL

UL UNDERWRITERS LABORATORY

VTR VENT THROUGH ROOF

ARCHITECTURAL STANDARD ABBREVIATIONS

ARCHITECTURAL PROJECT SPECIFIC ABBREVIATIONS

NA NOT APPLICABLE

WX-A1

WALL ASSEMBLY CATEGORY - FUNCTION

WALL BUILDING ENVELOPE DESIGNATION

WALL ASSEMBLY MODIFIER

WALL ASSEMBLY CATEGORY - FUNCTION

PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.

WF WALL - FOUNDATION

WP WALL - PARAPET

WR WALL - RETAINING

WX WALL - EXTERIOR

WALL BUILDING ENVELOPE DESIGNATION

A EIFS / EPDM / FOUNDATION

B RAINSCREEN / ATTIC

C IMP

D OTHER

WALL ASSEMBLY MODIFIER

NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY TYPES.

THE BELOW ARE COMMONLY USED EXAMPLES. SEE

ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

1 TYPICAL

EXTERIOR ASSEMBLY TAG LEGEND - WALL

R-A1

ROOF ASSEMBLY CATEGORY - FUNCTION

ROOF ASSEMBLY MODIFIER

ROOF ASSEMBLY CATEGORY - FUNCTION

R ROOF

RS ROOF - SOFFIT

ROOF BUILDING ENVELOPE DESIGNATION

A EIFS / EPDM / FOUNDATION

B RAINSCREEN / ATTIC

C IMP

D OTHER

WALL ASSEMBLY MODIFIER

NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY

TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.

SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

1 TYPICAL

EXTERIOR ASSEMBLY TAG LEGEND - ROOF

ROOF BUILDING ENVELOPE DESIGNATION

BUILDING ENVELOPE LEGEND

SEE EXTERIOR ASSEMBLY TYPES, EXTERIOR DETAILS,

MATERIAL SCHEDULE, AND SPECIFICATIONS FOR

ADDITIONAL INFORMATION. PROJECTS MAY NOT INCLUDE

ALL BUILDING ENVELOPE CATEGORIES.

DIRECTION

OF DRYING

BE-1 OR 2: FOUNDATION MEMBRANE

BE-4: INTERIOR AIR/VAPOR BARRIER

BE-5 OR 6: EXTERIOR AIR/WATER BARRIER

BE-7,8, OR 9: ROOF UNDLERLAY

BUILDING ENVELOPE COMPONENT

BUILDING ENVELOPE METAL FLASHING

DESCRIBES THE DIRECTION OF AIRFLOW IN A

VENTED OR VENTILATED ASSEMBLY

DESCRIBES THE DIRECTION AN ASSEMBLY

WILL DRY. PERMEABLE MATERIALS REQUIRED

TO DRY AS SHOWN

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

Q.

R.

S.

ARCHITECTURAL NOTES CONVEY INTENT OF WORK

COMPRISING THE ENTIRE ARCHITECTURAL DISCIPLINE.

SHEET NOTES CONVEY INTENT OF WORK COMPRISING

THE ENTIRE SHEET ON WHICH THE NOTES APPEAR

INCLUDING SHEETS ON WHICH THE NOTES ARE

REFERENCED.

CONSTRUCTION DOCUMENTS ARE PREPARED FOR THE

PURPOSES OF COMMUNICATING DESIGN INTENT.

DRAWINGS ARE GRAPHIC REPRESENTATIONS INTENDED

TO CONVEY THE QUANTITATIVE EXTENT AND

RELATIONSHIP BETWEEN ELEMENTS.

SPECIFICATIONS ARE WRITTEN REPRESENTATIONS

INTENDED TO CONVEY THE QUALITATIVE REQUIREMENTS

OF PROJECT ELEMENTS.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A

COMPLETE AND FINISHED PRODUCT FULFILLING THE

INTENT OF THE CONSTRUCTION DOCUMENTS.

THE TERM 'NEW' MAY BE USED TO DISTINGUISH NEW

FROM EXISTING IN SOME INSTANCES. OMISSION OF THE

TERM 'NEW' IS NOT NECESSARILY AN INDICATION THAT

THE ELEMENT IS EXISTING.

THE TERM 'ALL' MAY BE USED TO CLARIFY SCOPE.

OMISSION OF THE TERM 'ALL' IS NOT NECESSARILY AN

INDICATION THAT THE SCOPE IS LIMITED.

PROVIDE CONSTRUCTION IN COMPLIANCE WITH OSHA.

COORDINATE ARCHITECTURAL WORK WITH STRUCTURAL,

MECHANICAL, ELECTRICAL, AND OTHER DISCIPLINES.

PATCH, REPAIR, AND REFINISH EXISTING SURFACES TO

REMAIN, AFFECTED BY WORK.

FIELD VERIFY DIMENSIONS SHOWN TO EXISTING

CONSTRUCTION PRIOR TO WORK. NOTIFY ARCHITECT

WHERE DISCREPANCIES ARE DISCOVERED.

DIMENSIONS AT EXISTING CONSTRUCTION ARE

MEASURED FROM FACE OF EXISTING FINISH UNLESS

NOTED OTHERWISE.

DIMENSIONS AT NEW CONSTRUCTION ARE MEASURED

FROM FACE OF FRAMING UNLESS NOTED OTHERWISE.

CONFIRM DIMENSIONS INDICATED WITH 'FIELD VERIFY'

AND/ OR 'FV' PRIOR TO WORK.

DIMENSIONS INDICATED AS 'CLEAR' REQUIRE MINIMUM

CLEARANCE MEASURED TO FINISHED FACES, UNLESS

NOTED OTHERWISE.

DIMENSIONS INDICATED WITH '+/-' ARE INTENDED TO

BRING THE CONTRACTORS ATTENTION TO AREAS WITH

FLEXIBILITY GREATER THAN ADJACENT AREAS NOT

OTHERWISE INDICATED.

SEE SPECIFICATIONS FOR ALLOWABLE TOLERANCES.

CONFIRM MANUFACTURERS INSTRUCTIONS CONFORM TO

SPECIFIED TOLERANCES.

ARCHITECTURAL NOTES

THIS REFERENCE IS INTENDED TO ASSIST WITH THE LOCATION OF

INFORMATION IN A TYPICAL PROJECT. THIS PROJECT MAY VARY

FROM THE REPRESENTATION BELOW. SEE THE SHEET INDEX FOR

SPECIFIC SHEET SEQUENCE.

A0 SHEETS ARCHITECTURAL INFORMATION

A1 SHEETS ARCHITECTURAL DEMOLITION

A2 SHEETS FLOOR AND ROOF PLANS

A3 SHEETS EXTERIOR ELEVATIONS (NOT USED)

A4 SHEETS SECTIONS AND VERTICAL CIRCULATION (NOT USED)

A5 SHEETS EXTERIOR DETAILS AND ASSEMBLIES

A6 SHEETS INTERIOR PLANS

A7 SHEETS INTERIOR ELEVATIONS (NOT USED)

A8 SHEETS INTERIOR DETAILS AND ASSEMBLIES (NOT USED)

A9 SHEETS SCHEDULES (NOT USED)

THE TWO CHARACTER ALPHANUMERIC DESIGNATIONS REPRESENT

ALL SHEETS IN THE SERIES. FOR EXAMPLE, 'A1 SHEETS' DESCRIBES

A100 THROUGH A199.

ARCHITECTURAL SHEET SEQUENCE

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 3:47:17 PM

JB

GMC

ARCHITECTURAL

INFORMATION

A001

A.

B.

CONSTRUCTION DOCUMENTS ARE GENERALIZED TO

DESCRIBE INTENT OF DEMOLITION WORK. CONTRACTOR IS

RESPONSIBLE FOR PROVIDING SPECIFIC DEMOLITION WORK

REQUIRED TO ACCOMMODATE NEW WORK.

SEE MECHANICAL, AND ELECTRICAL DOCUMENTS FOR

ADDITIONAL DEMOLITION REQUIREMENTS.

DEMOLITION NOTES

KEYNOTES

DEMOLISH EXISTING ROOF PAVERS AND ROOFING

SYSTEM DOWN TO FACE OF POLY BARRIER; EXISTING

POLY, GYPSUM AND DECKING TO REMAIN. SEE A500 FOR

EXISTING ROOF ASSEMBLY.

DEMOLISH EXISTING PARAPET FLASHING, PARAPET WALL

COMPONENTS, AND PENTHOUSE WALL COMPONENTS

DOWN TO SHEATHING, TYPICAL AT PERIMETER OF

BUILDING; EXISTING SHEATHING TO REMAIN

REMOVE EXISTING PARAPET MOUNTED GUARD RAILING

AND SALVAGE FOR REINSTALLATION

REMOVE EXISTING ROOFTOP EQUIPMENT INCLUDING

SOLAR PANELS AND SALVAGE FOR REINSTALLATION

REMOVE EXISTING GROUNDING CABLE AND SALVAGE

FOR REINSTALLATION

EXISTING SCUPPER LOCATIONS TO REMAIN

EXISTING SATELLITE DISHES TO BE REMOVED BY OTHERS

PRIOR TO CONSTRUCTION

A

B

C

D

E

F

G

30'-0"

30'-0"

30'-0"

30'-0"

30'-0"

30'-0" 30 '-0

'-0

'-0

'-0

'-0

'-0

1 1

SLOPE DOWN

SLOPE DOWN

SLOPE DOWN

VALL

EY O

F R

OOF

RID

GE O

F R

OOF

VALL

EY O

F R

OOF

VALLEY OF ROOF

RIDGE OF ROOF

VALLEY OF ROOF

TYPICAL

AT PENTHOUSE

PERIMETER

TYPICAL

AT BUILDING

PERIMETER

WP-1

WX-1(E) WX-1

WX-1

WX-1

WX-1

7 7 7

4 4

4 TYPICAL

(E) WX-1

(E) WX-1

(E) WX-1

(E) WP-1

(E) WP-1

FAN ROOM

PLENUM

X

CONDENSING

ROOM

GENERATOR

ROOM

BOILER

ROOM

DEMOLITION LEGEND

EXISTING CONSTRUCTION

HATCH PATTERN INTENDED TO

CLARIFY SCOPE OF SPECIFIC

KEYNOTES INDICATED HERE

EXISTING WALL AND DOOR TO REMAIN

EXISTING CURB EQUIPMENT

EXISTING VTR

EXISTING ROOF DRAIN

GUARD RAIL

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 3:47:20 PM

JB

GMC

DEMOLITION PLAN

- PENTHOUSE AND

ROOF

A100 3/32" = 1'-0"A100

1 DEMOLITION PLAN - PENTHOUSE AND ROOF

ROOF PLAN NOTES

B.

C.

PROVIDE CONTINUITY OF BUILDING ENVELOPE PER

ASSEMBLY TYPES AND BUILDING ENVELOPE NOTES ON

A500; AND EXTERIOR DETAILS ON A5 SHEETS.

SEE MECHANICAL, ELECTRICAL, AND OTHER DISCIPLINES

FOR SIZE AND GENERAL LOCATION OF ROOF

PENETRATIONS.

UPON COMPLETION OF PARTIAL OR TOTAL ROOF

REMOVAL THE CONTRACTOR AND OWNER SHALL INSPECT

EXISTING POLY MEMBRANE FOR CONTINUITY AND REPAIR

UNSUITABLE AREAS. ALL REPAIRS TO BE DONE IN

CONFORMANCE WITH MANUFACTURERS INSTALLATION

REQUIREMENTS OF WARRANTIED ROOF ASSEMBLY.

KEYNOTES

PROVIDE COMPOSITE PAVERS OVER LOW SLOPE EPDM

ROOFING SYSTEM AS SHOWN ON A500

REINSTALL SALVAGED PARAPET MOUNTED GUARD

RAILING

REINSTALL SALVAGED ROOFTOP EQUIPMENT INCLUDING

SOLAR PANELS

TAPERED INSULATION SLOPED AT 1/4" : 1'-0", TYPICAL ALL

HATCHED AREAS

EXISTING SCUPPER LOCATION TO REMAIN

REINSTALL PERIMETER GROUNDING CABLE

CONDENSING

ROOM

PLENUM

FAN ROOM

GENERATOR

ROOM

BOILER

ROOM

A

B

C

D

E

F

G

30'-0"

30'-0"

30'-0"

30'-0"

30'-0"

30'-0" 30 '-0

'-0

'-0

'-0

'-0

'-0

WP-1

WX-1

(E) WX-1

WX-1

WX-1

WX-1

TYPICAL

AT PENTHOUSE

PERIMETER

TYPICAL

AT BUILDING

PERIMETER

1 1

SWI

SWS

1/4" : 1'-0"

SWS

1/4" : 1'-0"

SLOPE DOWN

SWS

1/4" : 1'-0"

SWS

1/4" : 1'-0"

1/4" : 1'-0"

SWI

1/4" : 1'-0"

SWS

1/4

1'- 0"

SWS

1/4

1'- 0"

SWS

1/4

1'- 0"

SWS

1/4

1'- 0"

4 TYPICAL ALL

SHADED AREAS

3 3

TYPICAL

6'-2"

TY

PI

C

AL

7' -1

/4

39'-4" +/-

30'-0" +/- 30 '-0

'-0

VALL

EY O

F R

OOF

RID

GE O

F R

OOF

VALL

EY O

F R

OOF

VALLEY OF ROOF

RIDGE OF ROOF

VALLEY OF ROOF

60'-0" +/-

'-4

/- 30

'-0

30'-0" +/-

30'-0" +/-

'-0

A510

2 TYPICAL

WP-1

ROOF PLAN LEGEND

ROOF DRAIN (RD)

SLOPE WITH INSULATION (SWI)

SLOPE WITH STRUCTURE (SWS)

VENT THROUGH ROOF (VTR)

EXISTING SOLAR PANELS

SWS

1/4" : 1'-0"

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 3:47:22 PM

JB

GMC

RENOVATION

PLAN -

PENTHOUSE AND

ROOF

A200 3/32" = 1'-0"A200

1 RENOVATION PLAN - PENTHOUSE AND ROOF

B.

C.

D.

E.

A.

B.

C.

D.

E.

F.

1 - TYPICAL

ASSEMBLIES ARE DIAGRAMS ONLY, DO NOT SCALE.

ASSEMBLIES ARE INTENDED TO DESCRIBE MATERIALS AND

THEIR RELATIONSHIP WITHIN A GIVEN CEILING, FLOOR, ROOF,

OR WALL. PENETRATIONS, JOINTS, FINISHES, AND

INTERSECTIONS BETWEEN ASSEMBLIES ARE NOT SHOWN.

SEE A0 SHEETS FOR ARCHITECTURAL NOTES, SHEET

SEQUENCE, AND ASSEMBLY TAG LEGENDS.

SEE A2 SHEETS FOR FLOOR PLAN ASSEMBLY LOCATIONS.

SEE A5 SHEETS FOR EXTERIOR DETAILS.

2 - BUILDING ENVELOPE

SEE SPEC DIVISION 07 AND RELATED SPEC SECTIONS.

SEE A001 FOR BUILDING ENVELOPE LEGEND.

BARRIER / RETARDER CONTINUITY IS CRITICAL FOR THE

PERFORMANCE AND DURABILITY OF THE ASSEMBLY.

FLASHING, SEALING, AND INSULATING TRANSITION SPACES

ARE CRITICAL COMPONENTS OF WATER, AIR, AND THERMAL

BARRIER CONTINUITY.

WATER RESISTIVE BARRIER COMPONENTS MUST BE

INSTALLED IN A SHINGLE FASHION (WEATHER LAPPED),

FROM FOOTING TO ROOF, WITH SUFFICIENT OVERLAP AND

NO EXPOSED CORNERS. AVOID TRAPPING MOISTURE IN

TIGHT SPACES OR CREATING FLAT HORIZONTAL AREAS THAT

CAN COLLECT WATER.

NOTIFY ARCHITECT OF BUILDING ENVELOPE COMPONENT

SUBSTITUTIONS. SOME PRODUCTS CAN SIMULTANEOUSLY

ACT AS A WATER RESISTIVE BARRIER, AIR BARRIER, AND/ OR

A VAPOR RETARDER. SUBSTITUTING ASSEMBLY

COMPONENTS WITHOUT ARCHITECTS APPROVAL CAN

DRASTICALLY ALTER THE DURABILITY AND ENERGY

PERFORMANCE OF THE ASSEMBLY.

EXTERIOR ASSEMBLY NOTES

INTERIOR EXTERIOR

DIRECTION

OF DRYING

EXISTING - WALL PARAPET - TYPICAL(E) WP-1

(E) R-1 ROOF ASSEMBLY - EXISTING

INTERIOR

EXTERIOR EXISTING R-38 UNIFORM THICKNESS RIGID

INSULATION (2 LAYERS)

EXISTING FILTER FABRIC

EXISTING BALLAST PAVERS

R-E2 ROOF ASSEMBLY - EPDM

INTERIOR

EXTERIOR

CONTINUOUS BE-8 MECHANICALLY FASTENED

MULTI LAYERED INSULATION R-43.

JOINTS STAGGERED

MINIMUM 5" AT ROOF DRAINS

EXISTING 5/8" DECK BOARD

INSULATION COVER BOARD

EPDM ROOFING AS SPECIFIED

EXISTING METAL DECK TO REMAIN

INTERIOR EXTERIOR

DIRECTION

OF DRYING

EXISTING - WALL EXTERIOR - AT PENTHOUSE(E) WX-1

EXISTING POLY SHEETING

EXISTING 1/2" PLYWOOD SHEATHING

EXISTING 3/16" NEOPRENE SPACERS

EXISTING VAPOR BARRIER

EXISTING 8" METAL STUDS WITH

R-30 BATT INSULATION

EXISTING 1/2" PLYWOOD SHEATHING

EXISTING 1/2" RESILIENT CHANNELS @ 16" O.C.

EXISTING 1" AIR SPACE

EXISTING 4" SPLIT FACE CMU

(SMOOTH FACE ACCENT BANDS)

EXISTING ROOF MEMBRANE AND ADHESIVE

EXISTING 5/8" TYPE 'X' GYPSUM BOARD

EXISTING VAPOR BARRIER

EXISTING 6" METAL STUDS WITH

R-19 BATT INSULATION

EXISTING 1/2" GYPSUM SHEATHING

EXISTING COATED INSULATION

BOARD

EPDM ROOF MEMBRANE SYSTEM

DRAINAGE LAYER

PAVER GRID

COMPOSITE PAVER

EXISTING PLYWOOD SHEATHING

EXISTING PREFINISHED METAL

FLASHING

INTERIOR EXTERIOR

DIRECTION

OF DRYING

WALL PARAPET - TYPICALWP-1

EXISTING 1/2" PLYWOOD SHEATHING

EXISTING 3/16" NEOPRENE SPACERS

EXISTING VAPOR BARRIER

EXISTING 8" METAL STUDS WITH

R-30 BATT INSULATION

EXISTING 1/2" PLYWOOD SHEATHING

EXISTING 1/2" RESILIENT CHANNELS @ 16" O.C.

EXISTING 1" AIR SPACE

EXISTING 4" SPLIT FACE CMU

(SMOOTH FACE ACCENT BANDS)

EPDM ROOFING AS SPECIFIED TO

WRAP UP PARAPET WALL

EXISTING GYPSUM WALL BOARD

EXISTING STEEL DECK

INTERIOR EXTERIOR

DIRECTION

OF DRYING

WALL EXTERIOR - AT PENTHOUSE WX-1

EXISTING 5/8" TYPE 'X' GYPSUM BOARD

EXISTING VAPOR BARRIER

EXISTING 6" METAL STUDS WITH

R-19 BATT INSULATION

EXISTING 1/2" GYPSUM SHEATHING

EXISTING COATED INSULATION

BOARD

EXISTING PLYWOOD SHEATHING

EXISTING PREFINISHED METAL

FLASHING

EXISTING ROOF MEMBRANE EPDM ROOFING AS SPECIFIED

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 3:47:23 PM

JB

GMC

EXTERIOR DETAIL

- ASSEMBLY TYPE

A500

BUILDING ENVELOPE INDEX

TYPE BASIS OF DESIGN - PER MATERIAL SCHEDULE

BE-8 GRACE ICE AND WATER SHIELD

EXTERIOR DETAIL NOTES

B.

C.

D.

E.

F.

SEE A0 SHEETS FOR NOTES AND LEGENDS.

EXTERIOR DETAILS ARE INTENDED TO SHOW BUILDING

ENVELOPE LAYER CONTINUITY AT TRANSITIONS.

CONSTRUCTION COMPONENTS MAY BE SIMPLIFIED OR

OMITTED FOR CLARITY.

SEE ELECTRICAL FOR EXTERIOR MOUNTED ITEMS,

INCLUDING, BUT NOT LIMITED TO LIGHTING,

RECEPTACLES, SENSORS, SIGNAGE, ANTENNAE, PANELS,

CONDUIT, AND JUNCTION BOXES. PROVIDE TREATED

BLOCKING, ATTACH TO PRIMARY FRAMING MEMBER, AND

WEATHER SEAL.

SEE MECHANICAL FOR EXTERIOR PENETRATIONS

INCLUDING BUT NOT LIMITED TO LOUVERS, DUCTS, PIPES,

FLUES, HOSE BIBBS, AND UTILITIES. PROVIDE TREATED

BLOCKING, ATTACH TO PRIMARY FRAMING MEMBER, AND

WEATHER SEAL.

PROVIDE PRE-FINISHED METAL FLASHING UNLESS NOTED

OTHERWISE. PERFORATE AT VENTED ASSEMBLIES.

PROVIDE TREATED 2x WOOD BLOCKING AT ROUGH

OPENINGS UNLESS NOTED OTHERWISE.

ROOF DRAIN

ROOF DRAIN

BOX

ROOF DRAIN

SUMP

SLOPE,

TYPICAL

4'-0"

2'-0"

4' -0

2' -0

NOTE: DRAIN SUMP DETAILS ARE

DIAGRAMMATIC IN NATURE. SEE ROOF PLAN

FOR SLOPES. SEE ASSEMBLIES FOR ROOF

CONSTRUCTION.

A510

EDGE OF

COMPOSITE

PAVERS,

GRID, AND

DRAINAGE

SHEET

4' -8

4'-8"

EPDM

MEMBRANE

GALVANIZED METAL FLASHING SYSTEM

APPROVED BY ROOF MANUFACTURER

LOW SLOPE ROOF PER ASSEMBLY

TYPE SEALED TO PIPE

BARRIER PER ASSEMBLY TYPE

SEALED TO PIPE

SEAL BASE PER ROOF MANUFACTURER

PIPE INSULATION AND GALVANIZED

METAL JACKETING PER MECHPER

ASSEMBLY

TYPE

PE

R

M

EC

H

AN

IC

AL

PRE-MOLDED PIPE BOOT FLASHING

SEAL TO PIPE PER ROOF MANUFACTURER

SEAL BE-8 TO DRAIN PIPE

AT SUMP

1'-0" TYPICAL

PER ASSEMBLY TYPE

ROOF/OVERFLOW DRAIN PER

MECHANICAL

INSTALL DRAIN BODY AT

DRAINBOX PER MANUFACTURER

INSTALL ROOFING MEMBRANE AT

DRAIN PER MANUFACTURER

3/4" PT PLYWOOD DRAINBOX TOP

RIP PT 2x TO MATCH SLOPE OF

DECK AND HEIGHT OF

INSULATION AT BASE OF SUMP

FILL ENTIRE VOID WITH

MINERAL WOOL

INSULATION. STAGGER

JOINTS AND DO NOT

COMPRESS BATTS.

CONTINUE MEMBRANE AT DRAIN BOX

INCREASE ROOF SLOPE AT SUMP

MECHANICALLY FASTEN

LIGHT GAUGE METAL

ANGLE TO DECK AND

DRAIN BOX

SLOPE PER ROOF PLAN

EPDM CONTINUOUS OVER CURB

2x STUD CONSTRUCTION.

FILL STUD CAVITY WITH

FOAM INSULATION

PRE-FINISHED METAL

FLASHING WITH CONTINUOUS

CLEAT AND DRIP EDGEEXISTING PENTHOUSE

EQUIPMENT

SEAL WEATHERTIGHT PER

EQUIPMENT MANUFACTURERS

INSTRUCTIONS

R-E2 R-E2

INTERIOR EXTERIOR

WP-1

RE-2

EXISTING

HANDRAIL

SYSTEM

PRE-FINISHED

METAL FLASHING

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 3:47:24 PM

JB

GMC

EXTERIOR DETAIL

- TYPICAL

A510

BUILDING ENVELOPE INDEX

TYPE BASIS OF DESIGN - PER MATERIAL SCHEDULE

BE-8 GRACE ICE AND WATER SHIELD

3/4" = 1'-0"A510

2 EXTERIOR DETAIL - ROOF - EPDM - DRAIN PLAN

1 1/2" = 1'-0"A510

3 EXTERIOR DETAIL - ROOF - EPDM - STEEL - INSULATED VTR PENETRATION

1 1/2" = 1'-0"A510

4 EXTERIOR DETAIL - ROOF - EPDM - STEEL - DRAIN SECTION

1 1/2" = 1'-0"A510

1 EXTERIOR DETAIL - ROOF - EPDM - MECHANICAL PENTHOUSE SECTION

1 1/2" = 1'-0"

EXTERIOR DETAIL - ROOF - PARAPET5

A510

CEILING PLAN NOTES

B.

C.

COORDINATE MECHANICAL ELEMENTS INCLUDING, BUT

NOT LIMITED TO DIFFUSERS, RETURN AIR SLOTS, ACCESS

PANELS, AND EQUIPMENT WITH MECHANICAL

DOCUMENTS.

COORDINATE ELECTRICAL ELEMENTS INCLUDING, BUT

NOT LIMITED TO LIGHTING, SENSORS, SPEAKERS,

SIGNAGE, ACCESS PANELS, AND EQUIPMENT WITH

ELECTRICAL DOCUMENTS.

COORDINATE FIRE ALARM AND FIRE SUPPRESSION

ELEMENTS INCLUDING, BUT NOT LIMITED TO SMOKE

DETECTORS, SPRINKLERS, ACCESS PANELS, AND

EQUIPMENT WITH FIRE PROTECTION, MECHANICAL, AND

ELECTRICAL DOCUMENTS.

CEILING PLAN LEGEND

EXISTING ACOUSTICAL CEILING TILE

OPEN TO STRUCTURE

NO WORK AREA

EXISTING GYPSUM BOARD CEILING

SECURE

STORAGE

COPY ROOM

ELECTRICAL

ELECTRICAL

COPY ROOM

MEN

CONFERENCE

CONFERENCE

GIS

COMPUTER

EQUIPMENT

CHIEF 3

WORD

PROCESSING

JANITOR

ARCH./PAL.

LAB

CHIEF 2

CHIEF 1

RECEPTION

CORRIDOR

LAND

MANAGMENT

UNIT 3

LAND

MANAGMENT

UNIT 4

LAND

MANAGMENT

UNIT 2

CORRDIOR

ELEVATOR

LOBBY

RECEPTION

CORRIDOR

WOMENS

CHIEF 4

ACTIVE

FILES

LIBRARY.WORK

AREA

CONFERENCE

CONFERENCE

CORRIDOR

LAND

MANAGEMENT

UNIT 1

CORRIDOR

226OPEN TO

BELOW

OPEN TO

BELOW

STAIR 2 STAIR 3

STAIR 1

CONFERENCE

ROOM

225.1

CONFERENCE

ROOM

225.2

OFFICE

201.1

KEYNOTES

ROOF DRAIN LOCATION ABOVE. PROVIDE CEILING WORK

AS REQUIRED TO ACCOMMODATE ROOF WORK.

AKAF AL

TS

TA E O

49 TH

S

JAMES D. BARTLETT

No. A10413

REGISTEREDPROFESSIONALARCHIT

EC

D E S I G N

A L

A S

K

AT

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEP-2021

9/17/2021 3:47:27 PM

JB

GMC

INTERIOR PLAN -

CEILING - 2ND

FLOOR

A620 3/32" = 1'-0"A620

1 INTERIOR PLAN - CEILING - 2ND FLOOR

ABBREVIATION FULL NAME

RL RAIN LEADER

EXISTING

EXISTING TO BE REMOVED

MECHANICAL - LINETYPES

LINETYPE

UNION

MECHANICAL SYMBOLS

PIPE CONNECTION

PIPE ELBOW TURNED DOWN

PIPE ELBOW TURNED UP

PIPE TEE DOWN

PIPE FLOW ARROW

CONNECTION TO EXISTING

PIPE CAP

PIPE BREAK

PLUMBING SCHEDULE

SYMBOL FIXTURE

DESCRIPTION

RD-1 ROOF DRAIN,

PRIMARY

WASTE

CONNECTION

SIZE (IN)

REMARKS

1. SEE SPECIFICATION FOR BASIS OF

DESIGN

INSULATE RAIN LEADER PIPING FOR 5 FT

FROM CONNECTION TO ROOF DRAIN BODY

TO INSIDE THE BUILDING. PROVIDE

FIBERGLASS INSULATION PREFORMED FOR

THE SPECIFIC PIPE SIZE WITH WHITE FACED

ASJ WITH VAPOR BARRIER COATING.

BUSHING TAP FOR ELECTRICAL

FITTING BY MANUFACTURER, TYP

6 POINT DE-ICING SYSTEM

CONTINUE THROUGH 6-POINT

DE-ICING SYSTEM, TYP

PRIMARY ROOF DRAIN6 POINT DE-ICING

SYSTEM

HEAT TRACE CABLE, (TYP)

LOOP AT ENDS, THEN FEED

BACK THROUGH CHANNELS,

(TYP)

ROOF DRAIN & DRAIN

BODY, TYP

PROVIDE AND MODIFY EXISTING

RAINLEADER PIPING AS REQUIRED TO

INSTALL WYE FITTING. WYE FITTING

MAY BE INSTALLED IN HORIZONTAL

PIPING PROVIDED FITTING AND

BUSHING FOR ELECTRICAL

CONNECTION IS ABOVE THE PIPE

CENTERLINE.

ROUTE HEAT TRACE TAPE THROUGH WYE

FITTING, LOOP CABLE. PROVIDE END FITTING

PER MANUFACTURER'S RECOMMENDATIONS.

POWER CONNECTION, SEAL FITTING

WITH GROMMET BY MFG, TYP

EXISTING RAIN LEADER PIPING

JUNCTION BOX, SEE

ELECTRICAL FOR ADDITIONAL

INFORMATION

HEATING CABLE FEEDS

THROUGH DRAIN BODY

18"

HEAT TRACE METAL CHANNEL

ROOFING PER ARCHITECTURE

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors

601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

9/17/2021 3:30:27 PM

MPC

ERM

MECHANICAL

ABBREVIATIONS,

LEGENDS,

SCHEDULES, AND

DETAILS

M001

KEY NAME ABBREVIATIONS

# NUMBER

& AND

(D) DEMOLITION

(E) EXISTING

(N) NEW

@ AT

AFF ABOVE FINISHED FLOOR

APPR APPROVED

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASSOC ASSOCIATED

C COMMON

CI CAST IRON

CO CLEAN OUT

DI DUCTILE IRON

DIA DIAMETER

DN DOWN

ELEC ELECTRICAL

EXIST EXISTING

GA GAUGE

GALV GALVANIZED

GI GALVANIZED IRON

ID INSIDE DIAMETER

IE INVERT ELEVATION

INSUL INSULATION

IPS IRON PIPE SIZE

MECH MECHANICAL

MIN MINIMUM

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI OWNER FURNISHED, OWNER INSTALLED

ORD OVERFLOW ROOF DRAIN

ORL OVERFLOW RAIN LEADER

RD ROOF DRAIN

RHW RECIRCULATING HOT WATER

RL RAIN LEADER

SIM SIMILAR

SPEC SPECIFICATIONS

SS STAINLESS STEEL

TYP TYPICAL

V VENT

VOL VOLUME

VTR VENT THROUGH ROOF

W WASTE

W/ WITH

W/O WITHOUT

WCO WALL CLEAN OUT

MECHANICAL ABBREVIATIONS

M001 NO SCALE

1 ROOF DRAIN HEAT TRACE

A K

AF AL

T S

T A

E O

49 TH

S

R E

G

ISTERED

PROFESS IONAL

ENG

IN

E

E R

D E

S I G

N

A L

A S

K

A17-SEP-2021

Marcus P. Curley

ME 14660

A

B

C

D

E

F

G

SPECIFIC NOTES

DEMOLISH EXISTING ROOF DRAIN.

(E) VENT THROUGH ROOF TO REMAIN.2

1 1

(E) PENTHOUSE ROOF DRAINAGE IS VIA GUTTERS

ON TO LOWER ROOF, GUTTERS TO REMAIN AS-IS

(E) EXHAUST FAN AND CURB TO REMAIN3

(E) EXHAUST HOOD TO REMAIN. 4

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors

601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

9/17/2021 3:30:28 PM

MPC

ERM

LOWER ROOF

PLUMBING

DEMOLITION PLAN

M100M100 3/32" = 1'-0"

1 LOWER ROOF PLUMBING DEMOLITION PLAN

A K

AF AL

T S

T A

E O

49 TH

S

R E

G

ISTERED

PROFESS IONAL

ENG

IN

E

E R

D E

S I G

N

A L

A S

K

A17-SEP-2021

A

B

C

D

E

F

G

RD-1, TYP

M001

SPECIFIC NOTES

(E) VENT THROUGH ROOF.1

(E) EXHAUST FAN AND CURB.2

(E) EXHAUST HOOD.3

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors

601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

9/17/2021 3:30:29 PM

MPC

MPC

ROOF PLUMBING

PLAN

M200M200 3/32" = 1'-0"

1 LOWER ROOF PLUMBING PLAN

A K

AF AL

T S

T A

E O

49 TH

S

R E

G

ISTERED

PROFESS IONAL

ENG

IN

E

E R

D E

S I G

N

A L

A S

K

A17-SEP-2021

ELECTRICAL SYMBOL LEGEND

J JUNCTION BOX

MOTOR (HP, VOLTAGE & PHASE NOTED ON DRAWING)

PANELBOARD

POWER SYMBOLS

RECEPTACLE; DUPLEX, QUADPLEX

+2'-0" AFF UON

GFCI RECEPTACLE; QUADPLEX, DUPLEX

+4'-0" AFF UON

SPECIAL RECEPTACLE

(NEMA TYPE NOTED ON DRAWING)

+4'-0" AFF UON

NON-FUSIBLE DISCONNECT

M

ANNOTATION SYMBOLS

L1-12

L1-12

AHU-1

PANEL & CIRCUIT IDENTIFICATION

PANEL & CIRCUIT IDENTIFICATION

B LIGHTING FIXTURE TAG (SEE LIGHTING FIXTURE SCHEDULE)

'L1' DENOTES PANEL NAME, '24' DENOTES CIRCUIT NUMBERL1-24

SPECIFIC NOTE KEY

(REFERENCE # UNDER 'SPECIFC NOTES' ON EACH SHEET)

a

SWITCH IDENTIFICATION TAG

a SWITCH IDENTIFIER

EQUIPMENT IDENTIFIER, SEE MECHANICAL ELECTRICAL SCHEDULE

AKAF AL

TS

TA E O

49 TH

S

D E S I G N

A L

A S

K A

REGISTERED PROFESSIONAL ENGIN

EE

R

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEPT-2021

Donald L Hopkins

EE 10582

9/16/2021 8:15:53 AM

DLH

DLH

ELECTRICAL

SYMBOLS,

LEGENDS AND

DETAILS

E001

SPECIFIC SHEET NOTES

1 REPLACE EXISTING BREAKER WITH NEW 20A GFPE BREAKER TO FEED DRAIN

BODY HEAT TRACE. WHERE NO SPARE BREAKER EXISTS AND P-2 IS FEEDING

LOADS, REPLACE BREAKER P-4 WITH A DUPLEX BREAKER AND CONNECT LOADS

FROM P-2 AND P-4 TO THIS NEW BREAKER.

NOTES:

CH CHILLER [NEC 2017, ARTICLE 440.33] 0 VA 0.00% 0 VA

H HBO [NEC 2017, ARTICLE 220.14(A)] 0 VA 0.00% 0 VA

A APPLIANCE [NEC 2017, ARTICLE 220.56] 0 VA 0.00% 0 VA

M MOTOR [NEC 2017, ARTICLE 430.24] 0 VA 0.00% 0 VA

R RECEPTACLES [NEC 2017, ARTICLE 220.44] 0 VA 0.00% 0 VA

L LIGHTING [NEC 2017, ARTICLE 215.2(A)(1)] 0 VA 0.00% 0 VA DEMAND LOAD: 0 VA 0 A

E NON-CONTINUOUS [NEC 2017, ARTICLE 215.2(A)(1)] 0 VA 0.00% 0 VA CONNECTED LOAD: 0 VA 0 A

C CONTINUOUS [NEC 2017, ARTICLE 215.2(A)(1)] 0 VA 0.00% 0 VA LOAD AMPS

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD PANEL TOTALS

TOTAL AMPS: 0 A 0 A 0 A

TOTAL LOAD: 0 VA 0 VA 0 VA

11 F/A R/B (LOCKING DEVICE ON BREAKER) -- 15 1 0 0 1 20 -- GUTTER HEAT TRACE (GFPE) 12 9 STATC PRESS CONT F-1 AIR HANDLER -- 15 1 0 0 1 20 -- U.P.S. DGPS NAVIGATOR ANT SYS. 10

7 OUTLET RECEPTACLE BELOW PANEL BOX P -- 15 1 0 0 1 20 -- REFRIGERATOR 8

5 HOT WATER HEATER & BURNER ASSY. -- 15 1 0 0 1 20 -- EMERGENCY GEN PERK HEATER 6

3 HOT WATER CIRC. PUMP #13 -- 15 1 0 0 1 20 -- BATTERY CHARDE FOR EMERG. GEN 4

1 FUME HOOD (EF-1) -- 15 1 0 0 1 20 -- (N) DRAIN BODY HEAT TRACE (GFPE) 2

CKT CIRCUIT DESCRIPTION LOAD

CLASS TRIP P A B C P TRIP LOAD

CLASS CIRCUIT DESCRIPTION CKT

ENCLOSURE: TYPE 1 MCB RATING: 100 A

MOUNTING: SURFACE WIRES: 4 MAINS RATING: 100 A

SUPPLY FROM: PHASES: 3 MAINS TYPE: MCB

LOCATION: BOILER ROOM 302 VOLTS: 208Y/120V A.I.C. RATING: 10000

PANEL: P

J J JJ

M

M

PV ARRAY 22 PANELS

5-SETS (4-RACK), 1 SET (2-RACK)

264W/PANEL = 5808W

3-PHASE CONNECTIONS

PV ARRAY 22 PANELS

5-SETS (4-RACK), 1 SET (2-RACK)

264W/PANEL = 5808W

3-PHASE CONNECTIONS

TREATED WOOD SLEEPER WITH RIGID

CONDUIT AND JUNCTION BOXES FOR

ROUTING DC CABLES FROM PV ARRAY

PV ARRAY ON

SECTIONED RACKS

WITH PAVER BALLASTS

CONDUIT SUPPORTED BY

CONSTRUCTION STRUT

AFFIXED TO PARAPET

CONDUIT SUPPORTED BY

CONSTRUCTION STRUT

SLEEPERS ON ROOF

LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN

CONDUITS AND DISCONNECT SWITCH

DISCONNECT SWITCH

TREATED WOOD SLEEPER WITH RIGID

CONDUIT AND JUNCTION BOXES FOR

ROUTING DC CABLES FROM PV ARRAY

LIQUID TIGHT FLEXIBLE CONDUIT BETWEEN

CONDUITS AND DISCONNECT SWITCH

CONDUIT SUPPORTED BY

CONSTRUCTION STRUT

AFFIXED TO PARAPET

PV ARRAY GROUNDING

CONDUCTOR BARE CU ROUTED

ALONG PARAPET THEN DOWN WALL

TO GROUND ROD AT GROUND LEVEL

EF-1

EF-2

WEST

ARRAY

INVERTER

EAST

ARRAY

INVERTER

PV DISCONNECTS

PV DISCONNECTS

PNL P

PNL PP

PNL MCCN

BUCKET EF-2

IN MCCN

BREAKER EF-1

PANEL P

1 1

CONDULETS AT PENETRATION

TO ROUTE ROOFTOP EQUIPMENT

5 5

G

F

E

D

C

B

A 1

DISCONNECT - WEST SIDE PV ARRAY

CONDUIT ROUTING ON SLEEPERS - WEST SIDE

PV ARRAY - WEST SIDE

PV INVERTERS IN PENTHOUSE

PV ARRAY - EAST SIDE

CONDUIT ROUTING ON SLEEPERS - WEST SIDE DISCONNECT - EAST SIDE & PARAPET CONDUIT

VIEW BEHIND WEST PV ARRAY SHOWING

MOUNTING RACKS AND BALLASTED FOOTERS

GROUND ROD LOCATION

(GROUND LEVEL)

EAST SIDE PV ARRAY & CONDUIT SUPPORT

RAIN GUTTER & DOWNSPOUT

(HEAT TRACED ~120' 12 W/FT)

(TYPICAL BOTH SIDES)

AKAF AL

TS

TA E O

49 TH

S

D E S I G N

A L

A S

K A

REGISTERED PROFESSIONAL ENGIN

EE

R

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

ISSUE DATE

COMM. NUMBER

DESIGNED BY

DRAWN BY

SCALE 0" 1"

Architects Engineers Surveyors 601 College Road Fairbanks AK 99701

907.452.1241 designalaska.com

20 SEP 2021

FAIRBANKS

DISTRICT OFFICE

ROOF

REPLACEMENT

902102

AECC511

NATIONAL SYSTEM OF PUBLIC LANDS

20-SEPT-2021

Donald L Hopkins

EE 10582

9/16/2021 8:16:16 AM

DLH

DLH

ELECTRICAL

ROOF PLAN

E100 E100 3/32" = 1'-0"

1 ROOF PLAN & DETAILS

SPECIFIC SHEET NOTES

1 CONTRACTOR TO PROVIDE NEW SLEEPERS THROUGHOUT FOR SUPPORTING OF CONDUITS ON NEW ROOF SYSTEM.

RE-USE OF THE EXISTING UNITS SHALL NOT BE ACCEPTABLE. NEW SLEEPERS SHALL BE EATON DURA BLOCK, nVENT CADDY OR OTHER EQUIVALENT RUBBER TYPE PIPE SUPPORT SYSTEM EQUAL AND NOT FABRICATED FROM INDIVIDUAL STRUT COMPONENTS AND TREATED WOOD AS THE EXISTING UNITS ARE. DISTANCE BETWEEN SLEEPERS SHALL NOT BE GREATER THAN 8' REGARDLESS OF NEC CONDUIT SUPPORT CRITERIA. WHERE DISTANCE ALONG ROOF OF CONDUITS ON SLEEPERS ARE FIXED ON TWO ENDS AND GREATER THAN 50 FEET, THE CONDUIT SHALL HAVE A BEND

OR EXPANSION FITTING TO ALLOW FOR THERMAL CHANGES IN THE RUN.

2 MOUNTING STRUT ON PARAPET TO BE REMOVED TO ACCOMMODATE THE ROOF WORK AND REPLACED. SPACING SHALL BE PER THE NEC FOR SUPPORTING OF THE CONDUITS WHEN RE-INSTALLED. CONTRACTOR SHALL SUPPORT ENDS OF

CONDUITS WITHIN 6" OF TRANSITIONS TO FLEXIBLE CONDUITS.

3 TREATED WOOD SUPPORTING THE CONDUITS ALONG THE FRONT OF THE PV ARRAYS SHALL NOT BE RE-USED AND

REPLACED WITH NEW MATERIALS.

4 CONTRACTOR SHALL CAREFULLY PAY ATTENTION TO PV ARRAY POWER SYSTEMS WHEN RE-CONNECTIONS TO ENSURE

THE POSITIVE AND NEGATIVE LEADS ARE NOT REVERSED IN THE INVERTER.

5 CONTRACTOR TO REMOVE FROM ROOF OR RELOCATE TO AREA ON ROOF THE PV ARRAYS, RACKING AND BALLAST AS NEEDED TO ACCOMMODATE NEW ROOF REPLACEMENT. CONDUITS MAY BE RE-USED, BUT CONDUCTORS TO BE REPLACED WHERE ANY DAMAGE OCCURS DURING THIS PROCESS. ONCE ROOF IS REPLACED, THE PV ARRAYS TO BE

LOCATED IN APPROXIMATELY THE SAME LOCATION AS IS CURRENTLY INSTALLED.

6 ROOF DRAIN BODY TO BE HEAT TRACED. PROVIDE NEW CONTROLLER FOR DRAIN BODIES TO PROVIDE HEAT TO THE DRAIN BODIES BETWEEN AMBIENT AIR TEMPERATURES OF 10 DEGREES F AND 40 DEGREES F. AT TEMPERATURES ABOVE OR BELOW THESE AMBIENT AIR TEMPERATURES THE HEATING CABLES TO BE DE-ENERGIZED TO SAVE ENERGY.

G001
C200
A001
A100
A200
A500
A510
A620
M001
M100
M200
E001
E100

File details come from the government source that posted it. Updated .