B01.01_Attachment A - Drawings for Description of Requirement (DOR).pdf

PDF 2 MB Posted

Attached to
Precast Concrete Components C-Channels and Slabs Federal contract opportunity
Solicitation number
W912HZ26QA015
Issued by
Department of the Army Corps of Engineers Engineer Research and Development Center

About this file

This document is a set of technical drawings for precast concrete components to be delivered to Fort Polk, Louisiana. The drawings provide detailed specifications for five distinct concrete product types: a 6-inch-thick C-Channel, a 9-inch-thick tall C-Channel, a floor isolation slab, a floor bearing pad, and a 9-inch-thick short C-Channel.

The 6-inch C-Channel (Drawing A) requires concrete with minimum 4,500 psi compression strength at 28 days, ASTM A615 Grade 60 reinforcement, total weight of 8,500 pounds with four lifting points each with minimum 1,500 lbs tension capacity, and chamfered edges with 2-inch [13mm] recommendation. The 9-inch tall C-Channel (Drawing B) specifies 4,500 psi concrete strength, ASTM A615 Grade 60 reinforcement, total weight of 13,000 pounds with four lifting points each with minimum 1,500 lbs tension capacity, and chamfered 2-inch edges. The floor isolation slab (Drawing C) requires 4,500 psi concrete, ASTM A615 Grade 60 #4 reinforcement bars, total weight of 4,300 pounds with four lifting points each with minimum 2,200 lbs tension capacity, and includes 1-inch schedule 40 PVC pipe thru-holes. The floor bearing pad (Drawing D) specifies 4,500 psi concrete, ASTM A615 Grade 60 #4 reinforcement, total weight of 1,100 pounds with four lifting points each with minimum 600 lbs tension capacity, and 1-inch schedule 40 PVC pipe thru-holes. The 9-inch short C-Channel (Drawing E) requires 6,000 psi 28-day compressive strength, ASTM A-615 Grade 60 reinforcement, and four lifting points each with minimum 6,000 lbs tension capacity. All products require minimum 1-inch [13mm] clear cover for reinforcement, prohibit welding or torch-cutting, and mandate adequate reinforcement securing to prevent movement during concrete placement.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT A – DRAWINGS

for

Description of Requirements for Precast Concrete C-Channel(s) and Slab(s) delivered to Fort Polk, LA

6-inch-thick C-Channel (Sheet 1 of 3) – DRAWING A

6-inch-thick C-Channel (Sheet 2 of 3) – DRAWING A

6-inch-thick C-Channel (Sheet 3 of 3) – DRAWING A

9-inch-thick, TALL, C-Channel (Sheet 1 of 3) – DRAWING B

9-inch-thick, TALL, C-Channel (Sheet 2 of 3) – DRAWING B

9-inch-thick, TALL, C-Channel (Sheet 3 of 3) – DRAWING B

Floor Isolation Slab (Sheet 1 of 4) – DRAWING C

Floor Isolation Slab (Sheet 2 of 4) – DRAWING C

Floor Isolation Slab (Sheet 3 of 4) – DRAWING C

Floor Isolation Slab (Sheet 4 of 4) – DRAWING C

Floor Bearing Pad (Sheet 1 of 4) – DRAWING D

Floor Bearing Pad (Sheet 2 of 4) – DRAWING D

Floor Bearing Pad (Sheet 3 of 4) – DRAWING D

Floor Bearing Pad (Sheet 4 of 4) – DRAWING D

9-inch-thick, SHORT, C-Channel (Sheet 1 of 5) – DRAWING E

9-inch-thick, SHORT, C-Channel (Sheet 2 of 5) – DRAWING E

9-inch-thick, SHORT, C-Channel (Sheet 3 of 5) – DRAWING E

9-inch-thick, SHORT, C-Channel (Sheet 4 of 5) – DRAWING E

9-inch-thick, SHORT, C-Channel (Sheet 5 of 5) – DRAWING E