B Existing Light Fixtures and Ballast Cut Sheets.pdf

PDF 623 KB Posted

Attached to
Z1HB--640-23-1-548-0010 Change lamping of light fixtures in vivarium (VA-23-00015180)
Solicitation number
36C26123R0022
Issued by

View the file

Other files

File Type Posted
S02 - RFI FORM.pdf PDF
C LED T8 Examples.pdf PDF
36C26123R0022.pdf PDF
A Electrical Lighting Plans.pdf PDF
Wage Determination CA20220018 08.12.2022.pdf PDF
D Lee Marius Red Insert Red Sleeve.pdf PDF
Animal Holding Room.jpg JPG image

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Series Trim Number of lamps Lamp type Door Lens Voltage

2SRT Cleanroom troffer 2x4

SRT Cleanroom troffer 1x4

For CF lamps in tandem, add prefix T. Example: T2SRT 2 CF40 (total 4 lamps)

G Grid, 1-1/2" wide tee

G10 Grid, 1-1/2" wide x2" tall1

G20 Grid, 2" wide tee (2x4 only)1

F Overlapping flange

Not included

28T5 28W T5 (46") 32 32W T8 (48")

54T5HO 54W T5HO (48")

FW Aluminum inset, white

FN Aluminum inset, natural

A12125V #12 pattern acrylic .125" thick, inverted A12156V #12 pattern acrylic .156” thick, inverted PCL12125V #12 pattern polycarbonate .125" thick, inverted SYA PSI symmetric/asymmetric acrylic .200" thick SYAR PSI symmetric/asymmetric acrylic with radio filter grid .200" thick2

T73V #73 pattern, tempered glass .190" thick, inverted

ARF12 #12 pattern with 3/8" radio frequency shield-ing grid .126" thick7

MVOLT3

ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: 2SRT G 4 32 FW A12125V MVOLT GEB10IS

INDUSTRIAL SRT-2X4-1X4-F

Catalog Number

Notes

Type

All dimensions are shown in inches (centimeters) unless otherwise specified.

FEATURES & SPECIFICATIONS

INTENDED USE — Suitable for use in (ISO 7 (Class 10,000) and ISO 8 (Class 100,000) cleanroom applications.

Ideal for medical and cleanroom changing areas and surgical suites. Certain airborne contaminants can diminish the integrity of acrylic and/or polycarbonate. Click here for Acrylic-Polycarbonate Compatibility table for suitable uses.

CONSTRUCTION — Available for T-Bar ceilings of 1", 1-1/2" width, or with overlapping flange and swing-out hangers for use in dry or plaster ceilings. For ceiling systems 1-1/2" wide up to 2" in height, you must specify G10. For ceiling systems 2" wide and up to 2" in height, you must specify G20. For all non-standard ceiling systems consult factory for compatibility. Verify fixture/ceiling compatibility with factory.

Code gauge steel housing is completely sealed with silicone caulk to prevent passage of particles into or out of fixture. Extruded aluminum, mitered corner doorframe features neoprene gasketing between door and housing. Door frame is hinged and cam latched from either side for easy maintenance. Latches are sealed with die-cut gasketing and injection-molded cap.

Lenses available to meet a variety of needs. Lenses feature internal prisms to maintain a smooth, easy-to-clean outer surface.

Suitable for low-pressure hosedown (LPD) up to 100 psi (see Options).

Finish: All metal parts are finished with electrostatically deposited, thermally set, polyester powder coat after fabrication. Antimicrobial paint finish available. See options listed below.

ELECTRICAL — Thermally protected, resetting, Class P, HPF, non-PCB, UL listed, CSA certified ballast is standard. Energy saving and electronic ballasts are sound rated A. Standard combinations conform to UL

935. Tested in compliance with Federal Standard 209E by independent lab.

LISTINGS — UL listed (standard). CSA certified or NOM Certified (see Options). UL listed and labeled for wet locations in covered ceiling applications. Tested in compliance with the International organization for Standardization (ISO) Worldwide Contamination Classification. UL listed for 25°C ambient temperatures.

WARRANTY — 1-year limited warranty. Complete warranty terms located at:

www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

Note: Actual performance may differ as a result of end-user environment and application.

Specifications subject to change without notice.

Notes

1. For use with any non-standard or Armstrong grid. Consult factory for availability and compatibility.

2. Lens gasketing not available for this lens type.

3. Electronic ballast 120-277V only.

4. Not available with MVOLT.

5. For one filter per ballast, specify RIF2.

6. Requires minimum .125'" thick lens.

7. Ground clip assembly has 6" - 8" wire lead with ring terminal. Installer to attach ring terminal to housing. Installer is responsible for ground clip attachment and appearance after installation.

8. Must specify LPD and additional gasketing (i.e. LG)

Specifications 2x4 1x4

Length: 48 (121.9) 48 (121.9) Width: 24 (61.0) 12 (30.5) Depth: 5 (12.7) 5 (12.7)

Recessed Cleanroom Troffer

SRT

2' x 4' 1' x 4'

1, 2, 3, 4 or 6 Lamps

(61.0)

(12.7)

(30.5)

(12.7)

Ballast Options

GEB10IS Electronic ballast(s) <10% THD, instant start GEB10PS Electronic ballast(s) <10% THD, program rapid start

Shipped installed in fixture GLR Internal fast-blow fuse4

GMF Internal slow-blow fuse4

RIF1 Radio interference filter (one per fixture)5

LG Lens and frame gasketing, neoprene ABC Triple gasketing, neoprene DWAM Antimicrobial white powder paint

CRE Flanged trim for continuous-row mounting (end) CRM Flanged trim for continuous-row mounting (middle) LATC Tee-bar clips, screw-down LPD Suitable for low-pressure hosedown, up to 100 psi6

CSA CSA Certified NOM NOM Certified BDP In-fixture ballast disconnect plug FPA Suitable for food-processing areas; meets USDA and FDA requirements8

SRT F 3 32 FW A12125V MVOLT

LPD ABC CRE

Catalog Number

SRT F 3 32 FW A12125V MVOLT ACNP LPD ABC CRE

Notes

Type

VR1

Project 15-37111 VA Research & VMU

Submitted By

16500, INC SAL NOT AVAILABLE WITH FLANGE TRIM

3 LAMP FIXTURES ARE DUAL CIRCUIT

Helix Page 61 of 70 vhapalcheyed Text Box EXISTING LIGHT FIXTURES AND BALLASTS. INCLUDED FOR INFORMATIONAL PURPOSES ONLY. PURCHASING NEW FIXTURES IS N.I.C.

SRT-2X4-1X4-F

INDUSTRIAL: One Lithonia Way Conyers, GA 30012 Phone: 800-315-4963 Fax: 770-981-8191 www.lithonia.com © 2004-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/06/18

MOUNTING DATA DIMENSIONS

PHOTOMETRICS

Calculated using the zonal cavity method in accordance with IESNA LM41 procedures. Floor reflectances are 20%.

Lamp configurations shown are typical. Full data on these and other configurations available upon request.

Grid 2x4 1x4 Length: 48 (121.9) 48 (121.9) Width: 24 (61.0) 12 (30.5) Depth: 5 (12.7) 5 (12.7) Weight: 28 lbs. (12.7) 24 lbs. (11kg)

Flange 2x4 1x4 Length: 49-3/16 (126.5) 49-3/16 (126.5) Width: 25-5/16 (64.3) 13-5/16 (33.8) Depth: 5-7/8 (14.6) 5-7/8 (14.6) Weight: 30 lbs. (13.6) 25.5 lbs. (11.6kg)

SRT 2x4 & 1x4 Recessed Cleanroom Troffers

Ceiling Type Appropriate Trim Type

Exposed grid, 1-1/2" wide tee, up to 1-1/2" tall Exposed grid, 1-1/2" wide tee, up to 2" tall Exposed grid, 2" tee, up to 2" tall Acoustical tile, plaster or plasterboard on rigid support parallel to lamps

G G10 G20

F

Recommended Rough-in Dimensions for F Trim

Size Ceiling Opening (+ 1/4-0)

2x4 1x4

Width 24-1/4" 12-1/4"

Length 48-1/4" 48-1/4"

Height Adj.

1-1/2" — 3-3/4" 1-1/2" — 3-3/4"

Span 23-1/2" — 26" 10-1/2" — 14"

(30.5)

5* (12.7)

(12.7)

(17.8)

(61.0)

(61.0)

(61.0)

5-1/8 (13.0)

2-5/8 (6.7)

2-5/8 (6.7)

2-9/16 (6.5)24

(61.0)

5* (12.7)

2-7/16 (6.2)

* Flange �xture height is 5-7/8 (14.9).

5* (12.7)

5* (12.7)

5* (12.7)

G20

END SIDE END SIDE END SIDE

H = up to 2”

H = up to 2”

W = up to 2”

G10* G

H = up to 1-1/2”

W = up to 1-1/2”

W = up to 1-1/2”

H = Height of tee grid W = Width of tee grid *For any other dimension not shown, consult factory for compatibility.

Coefficients of Utilization pf 20% pc 80% 50% 30% pw 70% 50% 30% 50% 30% 10% 50% 30% 10%

R C

R

Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 180° 0° - 180°

21.6 35.0 60.4 74.9 0.0 74.9

28.8 46.7 80.6

100.0 0.0

100.0

Report:

LUMENS PER LAMP:

LTL9127

Luminaire Efficiency: 74.9%

2SRT G 4 32 FW A12125V

Coefficients of Utilization pf 20% pc 80% 50% 30% pw 70% 50% 30% 50% 30% 10% 50% 30% 10%

R C

R

Zonal Lumen Summary

Zone Lumens % Lamp % Fixture 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 180° 0° - 180°

21.8 35.4 61.7 77.1 0.0 77.1

28.2 45.9 80.0

100.0 0.0

100.0

Report:

LUMENS PER LAMP:

LTL9138

Luminaire Efficiency: 77.1%

2SRT G 3 32 FW A12125V

Catalog Number

SRT F 3 32 FW A12125V MVOLT ACNP LPD ABC CRE

Notes

Type

VR1

Project 15-37111 VA Research & VMU

Submitted By

16500, INC

Helix Page 62 of 70

Series Trim Number of lamps Lamp type Door Lens Voltage

2SRT Cleanroom troffer 2x4

SRT Cleanroom troffer 1x4

For CF lamps in tandem, add prefix T. Example: T2SRT 2 CF40 (total 4 lamps)

G Grid, 1-1/2" wide tee

G10 Grid, 1-1/2" wide x2" tall1

G20 Grid, 2" wide tee (2x4 only)1

F Overlapping flange

Not included

28T5 28W T5 (46")2

32 32W T8 (48")

54T5HO 54W T5HO (48")2

FW Aluminum inset, white

FN Aluminum inset, natural

A12125V #12 pattern acrylic .125" thick, inverted A12156V #12 pattern acrylic .156” thick, inverted PCL12125V #12 pattern polycarbonate .125" thick, inverted SYA PSI symmetric/asymmetric acrylic .200" thick SYAR PSI symmetric/asymmetric acrylic with radio filter grid .200" thick3

T73V #73 pattern, tempered glass .190" thick, inverted

ARF12 #12 pattern with 3/8" radio frequency shield-ing grid .126" thick8

MVOLT4

ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: 2SRT G 4 32 FW A12125V MVOLT GEB10IS

INDUSTRIAL SRT-2X4-1X4-F

Catalog Number

Notes

Type

All dimensions are shown in inches (centimeters) unless otherwise specified.

FEATURES & SPECIFICATIONS

INTENDED USE — Suitable for use in (ISO 7 (Class 10,000) and ISO 8 (Class 100,000) cleanroom applications.

Ideal for medical and cleanroom changing areas and surgical suites. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses.

CONSTRUCTION — Available for T-Bar ceilings of 1", 1-1/2" width, or with overlapping flange and swing-out hangers for use in dry or plaster ceilings. For ceiling systems 1-1/2" wide up to 2" in height, you must specify G10. For ceiling systems 2" wide and up to 2" in height, you must specify G20. For all non-standard ceiling systems consult factory for compatibility. Verify fixture/ceiling compatibility with factory.

Code gauge steel housing is completely sealed with silicone caulk to prevent passage of particles into or out of fixture. Extruded aluminum, mitered corner doorframe features neoprene gasketing between door and housing. Door frame is hinged and cam latched from either side for easy maintenance. Latches are sealed with die-cut gasketing and injection-molded cap.

Lenses available to meet a variety of needs. Lenses feature internal prisms to maintain a smooth, easy-to-clean outer surface.

Suitable for low-pressure hosedown (LPD) up to 100 psi (see Options).

Finish: All metal parts are finished with electrostatically deposited, thermally set, polyester powder coat after fabrication. Antimicrobial paint finish available. See options listed below.

ELECTRICAL — Thermally protected, resetting, Class P, HPF, non-PCB, UL listed, CSA certified ballast is standard. Energy saving and electronic ballasts are sound rated A. Standard combinations conform to UL

935. Tested in compliance with Federal Standard 209E by independent lab.

LISTINGS — UL listed (standard). CSA certified or NOM Certified (see Options). UL listed and labeled for wet locations in covered ceiling applications. Tested in compliance with the International organization for Standardization (ISO) Worldwide Contamination Classification. UL listed for 25°C ambient temperatures.

WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

Note: Actual performance may differ as a result of end-user environment and application.

Specifications subject to change without notice.

Notes 1 For use with any non-standard or Armstrong grid. Consult factory for availability and compatibility.

2 Maximum number of lamps is four.

3 Lens gasketing not available for this lens type.

4 Electronic ballast 120-277V only.

5 Not available with MVOLT.

Specifications 2x4 1x4 Length: 48 (121.9) 48 (121.9) Width: 24 (61.0) 12 (30.5) Depth: 5 (12.7) 5 (12.7)

Recessed Cleanroom Troffer

SRT

2' x 4' 1' x 4'

1, 2, 3, 4 or 6 Lamps

(61.0)

(12.7)

(30.5)

(12.7)

Ballast Options

GEB10IS Electronic ballast(s) <10% THD, instant start GEB10PS Electronic ballast(s) <10% THD, program rapid start

Shipped installed in fixture GLR Internal fast-blow fuse5

GMF Internal slow-blow fuse5

RIF1 Radio interference filter (one per fixture)6

LG Lens and frame gasketing, neoprene ABC Triple gasketing, neoprene DWAM Antimicrobial white powder paint

CRE Flanged trim for continuous-row mounting (end) CRM Flanged trim for continuous-row mounting (middle) LATC Tee-bar clips, screw-down LPD Suitable for low-pressure hosedown, up to 100 psi7

CSA CSA Certified NOM NOM Certified BDP In-fixture ballast disconnect plug FPA Suitable for food-processing areas; meets USDA and FDA requirements9

6 For one filter per ballast, specify RIF2.

7 Requires minimum .125'" thick lens.

8 Ground clip assembly has 6" - 8" wire lead with ring terminal. Installer to attach ring terminal to housing. Installer is responsible for ground clip attachment and appearance after installation.

9 Must specify LPD and additional gasketing (i.e. LG)

SRT F 3 32 FW A12125V MVOLT

GEB10PS ABC

Catalog Number

SRT F 3 32 FW A12125V MVOLT GEB10PS ABC

Notes

Type

VR2

Project 15-37111-13 Date 7/13/2017 VA Research & VMU

Submitted By

SRT-2X4-1X4-F

INDUSTRIAL: One Lithonia Way Conyers, GA 30012 Phone: 800-315-4963 Fax: 770-981-8191 www.lithonia.com © 2004-2017 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/02/17

MOUNTING DATA DIMENSIONS

PHOTOMETRICS

Calculated using the zonal cavity method in accordance with IESNA LM41 procedures. Floor reflectances are 20%.

Lamp configurations shown are typical. Full data on these and other configurations available upon request.

Grid 2x4 1x4 Length: 48 (121.9) 48 (121.9) Width: 24 (61.0) 12 (30.5) Depth: 5 (12.7) 5 (12.7) Weight: 28 lbs. (12.7) 24 lbs. (11kg)

Flange 2x4 1x4 Length: 49-3/16 (126.5) 49-3/16 (126.5) Width: 25-5/16 (64.3) 13-5/16 (33.8) Depth: 5-7/8 (14.6) 5-7/8 (14.6) Weight: 30 lbs. (13.6) 25.5 lbs. (11.6kg)

SRT 2x4 & 1x4 Recessed Cleanroom Troffers

Ceiling Type Appropriate Trim Type

Exposed grid, 1-1/2" wide tee, up to 1-1/2" tall Exposed grid, 1-1/2" wide tee, up to 2" tall Exposed grid, 2" tee, up to 2" tall Acoustical tile, plaster or plasterboard on rigid support parallel to lamps

G G10 G20

F

Recommended Rough-in Dimensions for F Trim

Size Ceiling Opening (+ 1/4-0)

2x4 1x4

Width 24-1/4" 12-1/4"

Length 48-1/4" 48-1/4"

Height Adj.

1-1/2" — 3-3/4" 1-1/2" — 3-3/4"

Span 23-1/2" — 26" 10-1/2" — 14"

(30.5)

5* (12.7)

(12.7)

(17.8)

(61.0)

(61.0)

(61.0)

5-1/8 (13.0)

2-5/8 (6.7)

2-5/8 (6.7)

2-9/16 (6.5)24

(61.0)

5* (12.7)

2-7/16 (6.2)

* Flange �xture height is 5-7/8 (14.9).

5* (12.7)

5* (12.7)

5* (12.7)

G20

END SIDE END SIDE END SIDE

H = up to 2”

H = up to 2”

W = up to 2”

G10* G

H = up to 1-1/2”

W = up to 1-1/2”

W = up to 1-1/2”

H = Height of tee grid W = Width of tee grid *For any other dimension not shown, consult factory for compatibility.

Coefficients of Utilization pf 20% pc 80% 50% 30% pw 70% 50% 30% 50% 30% 10% 50% 30% 10%

R C

R

Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 180° 0° - 180°

21.6 35.0 60.4 74.9 0.0 74.9

28.8 46.7 80.6

100.0 0.0

100.0

Report:

LUMENS PER LAMP:

LTL9127

Luminaire Efficiency: 74.9%

2SRT G 4 32 FW A12125V

Coefficients of Utilization pf 20% pc 80% 50% 30% pw 70% 50% 30% 50% 30% 10% 50% 30% 10%

R C

R

Zonal Lumen Summary

Zone Lumens % Lamp % Fixture 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 180° 0° - 180°

21.8 35.4 61.7 77.1 0.0 77.1

28.2 45.9 80.0

100.0 0.0

100.0

Report:

LUMENS PER LAMP:

LTL9138

Luminaire Efficiency: 77.1%

2SRT G 3 32 FW A12125V

Catalog Number

SRT F 3 32 FW A12125V MVOLT GEB10PS ABC

Notes

Type

VR2

Project 15-37111-13 Date 7/13/2017 VA Research & VMU

VIS ION 8 Vandal Resistant

VPF 8 Series Fluorescent

Job Name

Fixture TypeWALL / CEILING/

PENDANT MOUNT

LAMPS: T5, T5HO, T8

Catalog Number

Approved By

Date

5 Sutton Place P.O. Box 2162 Edison, NJ 08818

P. 732.549.0056 F. 732.549.9737www.luminaireled.net

Rev: 01/17

Luminaire LED Incorporated products are manufactured in the USA with components purchased from USA suppliers, and meet the Buy American requirements under the ARRA. Content of specification sheets is subject to change; please consult our website for current product information.

Description The Vision 8 series features an all aluminum construction and optional wet location listing which allows it to be used in nearly any environmental condition. Designed in conjunction with an opthalmologist, the polycarbonate lens provides complete control of glare and lamp image while maintaining the high efficiency of clear optical material. The Vision 8 series can be row mounted to any length and can be equipped with energy efficient occupancy sensors. Natatorium finish is standard for all versions of this fixture.

Housing Marine grade heat treated extruded aluminum.

Chemically primed and finished with robotically applied polyester powder coat.

Lens Extruded UV stabilized opal polycarbonate with integral prisms.

Maximum wall thickness 0.160’’. Secured to housing with die cast aluminum clamps and stainless steel TORX® head screws.

End Caps Die-cast marine grade aluminum with conduit knockouts that are visible from interior of end cap.

Ballast Electronic high frequency ballast with less than 10% total harmonic distortion, 120V-277V, 347V optional.

Sockets Precision spring loaded snap type for maximum impact damping.

UL Listing U.L., C.UL., Damp Standard, Wet optional.

Lifetime Luminaire LED Incorporated will repair or replace any fixture damaged due to Warranty vandalism for the lifetime of the installation.

ULC US®

ADA CompliantSPECIFICATIONS

A B C

VPF82HO 26.07 8.75 4.00

VPF82 27.64 8.75 4.00

VPF83HO 37.87 8.75 4.00

VPF83 39.68 8.75 4.00

VPF84HO 49.68 8.75 4.00

VPF84 51.68 8.75 4.00

DIMENSIONAL DATA

B

C

A

Catalog Number

VPF84 3F32T8 120-277 CP WHT 2B WET JB

Notes

Type

VQ3

Project 15-37111-13 Date 7/13/2017 VA Research & VMU

Vandal Resistant

VPF 8 Series FluorescentFixture Type

VIS ION 8

5 Sutton Place P.O. Box 2162 Edison, NJ 08818

P. 732.549.0056 F. 732.549.9737www.luminaireled.net

Rev: 01/17

Luminaire LED Incorporated products are manufactured in the USA with components purchased from USA suppliers, and meet the Buy American requirements under the ARRA. Content of specification sheets is subject to change; please consult our website for current product information.

ORDERING INFORMATION

SERIES LAMPS VOLTS LENS COLOR OPTIONS TX/SD

(NOT INCLUDED) TX/SD

VPF82 HO 22” 22” - 1F14T5 36” - 1F25T8 120-277 CP BLK PC EMB50

VPF82 24” 22” - 2F14T5 36” - 2F25T8 347 OP WHT GLR EMB100

VPF83 HO 34” 22” - 3F14T5 36” - 3F25T8 BRZ WET EMB600

VPF83 36” 22” - 1F24T5HO GRY NSF ST/SC

VPF84HO 46” 22” - 2F24T5HO 46” - 1F28T5 CUST JB

VPF84 48” 46” - 2F28T5 COR

24” - 1F17T8 46” - 3F28T5 CW

24” - 2F17T8 46” - 1F54T5HO PRS

24” - 3F17T8 46” - 2F54T5HO LEDNL

OCC

34” - 1F21T5 48” - 1F32T8

34” - 2F21T5 48” - 2F32T8

34” - 3F21T5 48” - 3F32T8

34” - 1F39T5HO

34” - 2F39T5HO

LENS CP = Clear Prismatic Standard OP = Opal Optional

COLORS BLK = Black WHT = White BRZ = Bronze GRY = Gray CUST = Custom Color (Consult Factory) PC Photoelectric switch.

GLR Fuse and fuse holder.

WET Silicone and neoprene gasketing for wet location. Surface mount only.

NSF National Sanitation Foundation rated. White finish only.

JB Die cast joiner band for continuous row mount. Consult factory for row information.

COR Corner mounted back box. Constructed from 16 gauge cold rolled zinc coated steel.

Finished with white powder coat. Damp only.

CW Cold Weather instant ballast, -20ºF minimum starting temperature. Available for T8 lamps only.

PRS Programmed rapid start electronic ballast for T8 lamps. Available for 24”, 36” and 48” lengths.

LEDNL LED Night Light.

OCC Microwave occupancy sensor mounted behind the lens. Available for 2-lamp configurations only.

EMB 50 950-1350 lumen self contained 90 minute emergency battery pack.

0 ºC (32 ºF) to 55 ºC (131 ºF) operating range. Available for 24”, 36”and 48” lengths.

Not available in 347V.

EMB100 350-450 lumen self contained 90 minute emergency battery pack.

0 ºC (32 ºF) to 55 ºC (131 ºF) operating range. Available for 24”, 36”and 48” lengths.

Not available in 347V.

EMB600 1025-1250 lumen self contained 90 minute emergency battery pack.

0 ºC (32 ºF) to 50 ºC (122 ºF). Available for 34” and 46” lengths. Not available in 347V.

ST/SC Slotted screws instead of TORX® head.

TX/SD TORX® head bit.

OPTIONS

VPF84

WHTCP48"-3F32T8 120-277VPF84 48" WET-JB-

3F32T8 120-277 CP WHT WET-JB-

Catalog Number

VPF84 3F32T8 120-277 CP WHT 2B WET JB

Notes

Type

VQ3

Project 15-37111-13 Date 7/13/2017 VA Research & VMU

Revised 01/30/12

Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.

ADVANCE TRANSFORMER CO.

O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018

Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 847-768-7768 Corporate Offices: Phone: 800-322-2086

ICN-2P32-N @ 120V

Brand Name CENTIUM Ballast Type Electronic

Starting Method Instant Start Lamp Connection Parallel

Input Voltage 120-277 Input Frequency 50/60 HZ

Status Active

Electrical Specifications

Lamp Type Num.

of

Lamps

Rated Lamp Watts

Min. Start Temp (°F/C)

Input Current (Amps)

Input Power

(ANSI

Watts)

Ballast Factor

MAX

THD

Power Factor

MAX Lamp Current Crest

Factor

B.E.F.

* F17T8 1 17 0/-18 0.17 21 1.08 10 0.99 1.6 5.14 F17T8 2 17 0/-18 0.26 32 0.90 10 0.99 1.6 2.81 F25T8 1 25 0/-18 0.24 29 1.05 10 0.99 1.6 3.62 F25T8 2 25 0/-18 0.38 45 0.89 10 0.99 1.6 1.98 F32T8 1 32 0/-18 0.31 37 1.05 10 0.99 1.6 2.84 F32T8 2 32 0/-18 0.49 56 0.89 10 0.99 1.6 1.59

F32T8/ES (25W) 1 25 60/16 0.24 28 1.05 10 0.99 1.6 3.75

F32T8/ES (25W) 2 25 60/16 0.38 45 0.92 10 0.99 1.6 2.04

F32T8/ES (28W) 1 28 60/16 0.24 31 1.03 10 0.99 1.6 3.32

F32T8/ES (28W) 2 28 60/16 0.41 48 0.89 10 0.99 1.6 1.85

F32T8/ES (30W) 1 30 60/16 0.28 33 1.03 10 0.98 1.6 3.12

F32T8/ES (30W) 2 30 60/16 0.45 54 0.89 10 0.99 1.6 1.65

F40T8 1 40 32/00 0.35 42 1.00 10 0.98 1.6 2.38

Wiring Diagram

The wiring diagram that appears above is for the lamp type denoted by the asterisk (*)

Standard Lead Length (inches)

in. cm.

Black 24 61 White 24 61

Blue 28 71.1 Red 45 114.3

Yellow 0 Gray 0

Violet 0

in. cm.

Yellow/Blue 0 Blue/White 0

Brown 0 Orange 0

Orange/Black 0 Black/White 0

Red/White 0

BALLAST

Diag. 68

LAMP

WHITE

BLACK

RED

BLUE

LINE

BLUE

Insulate unused blue lead for 1000V

Enclosure

Enclosure Dimensions OverAll (L) Width (W) Height (H) Mounting (M)

9.5 " 1.3 " 1.0 " 8.9 " 9 1/2 1 3/10 1 8 9/10

24.1 cm 3.3 cm 2.5 cm 22.6 cm

Helix Page 64 of 70

ICN-2P32-N @ 120V

Brand Name CENTIUM Ballast Type Electronic

Starting Method Instant Start Lamp Connection Parallel

Input Voltage 120-277 Input Frequency 50/60 HZ

Status Active

Electrical Specifications

Notes:

Section I - Physical Characteristics

1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.

1.2 Ballast shall be provided with integral leads color-coded per ANSI C82.11.

Section II - Performance

2.1 Ballast shall be __________ (Instant, Rapid or Programmed) Start.

2.2 Ballast shall provide Independent Lamp Operation (ILO) for Instant Start ballasts allowing remaining lamp(s) to maintain full light output when one or more lamps fail.

2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power (except T8/HO ballast).

2.4 Ballast shall operate from 50/60 Hz input source of ___________ (120V through 277V or 347V through 480V) with sustained variations of +/- 10% (voltage and frequency).

2.5 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker.

2.6 Ballast shall have a Power Factor greater than 0.98 for primary lamp.

2.7 Ballast shall have a minimum ballast factor for primary lamp application as follows: 0.75 for Low Watt, 0.85 for Normal Light Output and

1.20 for High Light.

2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less.

2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.

2.10 Ballast shall have a Class A sound rating for all 4-foot lamps and smaller.

2.11 Ballast shall have a minimum starting temperature of _______ [-18C (0F) for standard T8 and Long Twin Tube lamps, 10C (50F) for standard T12 lamps, 0C (32F) for Slimline T8 lamps, -29C (-20F) for HO lamps,] for primary lamp application. Ballast shall have a minimum starting temperature of 16C (60F) for energy-saving lamps.

2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions.

2.13 Ballast for T8 lamps shall provide lamp striation-reduction circuitry.

2.14 Ballast for FT5 lamps shall provide lamp EOL protection circuitry.

Section III - Regulatory

3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).

3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable.

3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection.

3.4 Ballast shall comply with ANSI C82.11 where applicable.

3.5 Ballast shall comply with applicable requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, for Non-Consumer equipment.

3.6 Ballast shall comply with NEMA 410 for in-rush current limits.

3.7 Ballast for T8 lamps shall meet NEMA Premium/CEE High Performance T8 Lighting System Specifications.

3.8 Ballast shall meet RoHS Compliance Standards

Section IV - Other

4.1 Ballast shall be manufactured in a factory certified to ISO 9001 Quality System Standards.

4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 70C.

4.3 Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market.

4.4 Energy saving T8 lamps (25W, 28W or 30W) may experience lamp striations if operated on ballasts not rated for their use.

Revised 01/30/12

Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.

ADVANCE TRANSFORMER CO.

O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD - ROSEMONT, ILLINOIS 60018

TELEPHONE: (847)390-5000 FAX: (847)768-7768

Helix Page 65 of 70