This is a salient characteristics document detailing equipment requirements for a pre-solicitation request for information issued by the United States Marine Corps. The solicitation (M00264-26-RFI-017) seeks pricing and availability information for two primary items: a Level 3 electric vehicle charger and a diesel generator, with delivery required to the USMC Motor Transport Platoon at Joint Base Anacostia Bolling in Washington, DC as soon as possible.
The Level 3 EV charger must deliver 60-125 kW of power with dual CCS Type 1 connectors, a 15-35 foot cable, operate across -25 to 125 degrees Fahrenheit, feature forced air cooling, accept 480 VAC input, and output 50-1,000 VDC. The diesel generator must provide 100-150 kW of power, run on Diesel #2 fuel with 50-100 gallon capacity or larger, be EPA-certified, support 480/277V three-phase voltage options, and be trailer-mounted when possible. Both items require preventative maintenance every 500 hours or annually, with mobile technician support for emergency and software issues. The diesel generator must be manufactured in the USA or comply with DFARS Buy American provisions. Respondents must include pricing for both purchase and lease options, specify socioeconomic business categories, and provide delivery, installation, startup, training, and pickup services at no additional cost. The document is marked for DoD community distribution only.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Performance Work Statement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTION OF REQUIREMENT:
| CLIN |
| SUPPLIES / SERVICES |
| QTY |
| UNIT |
| 0001 |
| Level 3 Electric Vehicle Charger |
| 1 |
| Each |
Salient Characteristics:
Power Output (kW): 60 kW-125 kW Output Connector Type: 2 x CCS Type 1 Cable Length (Ft): 15-35 Feet Operating Temperature (Fahrenheit): -25 to 125 Cooling Method: Forced Air Cooling Rated Input Voltage (V): 480 VAC Output Voltage Range: 50-1,000 VDC Maintenance/Software Services: Preventative maintenance every 500 hours or 365 days. Mobile technicians are available to assist with any emergency maintenance issues or software issues and updates.
| CLIN |
| SUPPLIES / SERVICES |
| QTY |
| UNIT |
| 0002 |
| Diesel Generator |
| 1 |
| Each |
Salient Characteristics:
Power Output (kW): 100 kW-150 kW Fuel Type: Diesel #2 Fuel Capacity (gal): 50-100 gal. or large capacity for fewer interruptions.
Mounted on a trailer Engine: Powered by clean running EPA certified engine.
Voltage Options: 480/277V three phase Fuel Service: If diesel generator is trailer mounted MBW will utilize fuel card to refuel generator through GSA. If diesel generator is not trailer mounted MBW will need fuel services to refuel generator on-call.
Maintenance Services: Preventative maintenance every 500 hours or 365 days. Mobile technicians are available to assist with any emergency maintenance issues.
*COO - Country of Origin (for Supplies). Must be manufactured in the U.S.A. or compliant with DFARS clause 252.225-7036 Buy American-Free Trade Agreements-Balance of Payments Program at https://www.acquisition.gov/dfars
Incidental Service: Equipment delivery, equipment installment, equipment startup, customer training, and equipment pickup must be included.
DELIVERY DATE AND LOCATION
Required Delivery Date: The soonest possible delivery date.
Location: USMC Motor Transport Platoon 2874 Defense Blvd, Bldg 400A Joint Base Anacostia Bolling Washington, DC 20373
DISTRIBUTION: DoD COMMUNITY ONLY
DISTRIBUTION: DoD COMMUNITY ONLY
MCINCR RCO – RA Salient Characteristics – Strategic BranchDISTRIBUTION: DoD COMMUNITY ONLY
Fiscal Year 2025_Ver.1
File details come from the government source that posted it. Updated .