B.08.02 Section 011010_Att#3_Conceptual Architecture Drawings_07APR2022.pdf

PDF 146 KB Posted

Attached to
Skriveri Nursing Home Renovation: Latvia
Solicitation number
W912GB22R0025
Issued by

About this file

This document contains a solicitation announcement and related contract opportunity documents for the renovation of the Skriveri Nursing Home in Latvia. The U.S. Army Corps of Engineers, Europe District is soliciting proposals for a design-build contract that includes completing 100% design and construction of the project. Interested offerors must be registered in the System for Award Management and submit both price and non-price proposals by the deadline of 11 May 2022. The project site is located 80 km from Riga, Latvia at the specified address. A pre-proposal site visit is scheduled for 11 May 2022 and pre-registration is required. Offerors should review the solicitation documents attached here and on SAM.gov for full details on proposal submission requirements and evaluation criteria.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

9.

5.5 m²

Entry

9.2 m²

Lobby

8.4 m²

Utility

17.6 m²

Hallway Unit 1

12.6 m²

Bedroom 1.1

12.7 m²

Bedroom 1.2

12.7 m²

Bedroom 1.3

12.6 m²

Bedroom 1.4

18.3 m²

Common Room Unit

6.1 m²

Bathroom 1

2.6 m²

Toilet

17.6 m²

Hallway Unit 2

12.6 m²

Bedroom 2.1

12.7 m²

Bedroom 2,2

12.7 m²

Bedroom 2.3

12.3 m²

Bedroom 2.4

2.6 m²

Toilet

6.1 m²

Bathroom 2

18.2 m²

Common Room Unit

18.1 m²

Hallway Unit 3

12.6 m²

Bedroom 3.1

12.7 m²

Bedroom 3.2

12.7 m²

Bedroom 3.3

12.6 m²

Bedroom 3.4

18.0 m²

Common Room Unit

6.0 m²

Bathroom 3

2.6 m²

Toilet

18.0 m²

Hallway Unit 4

12.6 m²

Bedroom 4.1

12.7 m²

Bedroom 4.2

12.7 m²

Bedroom 4.3

12.3 m²

Bedroom 4.4

2.6 m²

Toilet

6.0 m²

Bathroom4

17.9 m²

Common Room Unit

50.860

9.

2.5003.000

2.

1.

4.

1.300 2.720

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-101

G R

O U

N D

F

LO

O R

P

LA

N

SK

R

IV

ER

I, LA

TV

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

S

EC

TI

O

N

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

C O

N

ST

R U

C

TI

O N

N U

R

SI

N G

H O

M E

O H

AS

IS

1 : 100A-101

1 GROUND FLOOR PLAN

G. FLOOR ROOM SCHEDULE

ROOM

NUMBER ROOM NAME

NET AREA

(SQM)

104 Entry 5.5 m² 105 Lobby 9.2 m² 106 Utility 8.4 m² 107 Hallway Unit 1 17.6 m² 108 Bedroom 1.1 12.6 m² 109 Bedroom 1.2 12.7 m² 110 Bedroom 1.3 12.7 m² 111 Bedroom 1.4 12.6 m² 112 Common Room Unit 1 18.3 m² 113 Bathroom 1 6.1 m² 114 Toilet 2.6 m² 115 Hallway Unit 2 17.6 m² 116 Bedroom 2.1 12.6 m² 117 Bedroom 2,2 12.7 m² 118 Bedroom 2.3 12.7 m² 119 Bedroom 2.4 12.3 m² 120 Toilet 2.6 m² 121 Bathroom 2 6.1 m² 122 Common Room Unit 2 18.2 m² 123 Hallway Unit 3 18.1 m² 124 Bedroom 3.1 12.6 m² 125 Bedroom 3.2 12.7 m² 126 Bedroom 3.3 12.7 m² 127 Bedroom 3.4 12.6 m² 128 Common Room Unit 3 18.0 m² 129 Bathroom 3 6.0 m² 130 Toilet 2.6 m² 131 Hallway Unit 4 18.0 m² 132 Bedroom 4.1 12.6 m² 133 Bedroom 4.2 12.7 m² 134 Bedroom 4.3 12.7 m² 135 Bedroom 4.4 12.3 m² 136 Toilet 2.6 m² 137 Bathroom4 6.0 m² 138 Common Room Unit 4 17.9 m²

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

N 0 1 5 m

1:100

SCALE

ATTACHMENT #3 CONCEPTUAL ARCHITECTURE DRAWINGS

NOTE:

FURNITURE EXCEPT BATHROOM FURNITURE AND KITCHENETTE

SHOWN ON THE CONCEPTUAL DESIGN IS FOR INFORMATION

ONLY AND NOT PART OF THE SOW.

A-201

A-201

A-201

AN201

AN201

AN201

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-104

R O

O F

PL

AN

SK

R

IV

ER

I, LA

TV

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

S

EC

TI

O

N

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

C O

N

ST

R U

C

TI

O N

N U

R

SI

N G

H O

M E

O H

AS

IS

1 : 100A-104

1 ROOF PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

N 0 1 5 m

1:100

SCALE

ATTACHMENT #3 CONCEPTUAL ARCHITECTURE DRAWINGS

G. FLOOR

-0.300

ROOF

2.700

G. FLOOR

-0.300

ROOF

2.700

G. FLOOR

-0.300

ROOF

2.700

G. FLOOR

-0.300

ROOF

2.700

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-201

EX

TE

R

IO

R E

LE

VA

TI

O

N S

SK

R

IV

ER

I, LA

TV

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

S

EC

TI

O

N

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

C O

N

ST

R U

C

TI

O N

N U

R

SI

N G

H O

M E

O H

AS

IS

1 : 100A-201

1 NORTH ELEVATION

1 : 100A-201

3 SOUTH ELEVATION

1 : 100A-201

2 EAST ELEVATION

1 : 100A-201

4 WEST ELEVATION# NOTE# NOTE

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

0 1 5 m

1:100

SCALE

ATTACHMENT #3 CONCEPTUALARCHITECTURE DRAWINGS

Ground Floor Plan
Sheets
A-101 - GROUND FLOOR PLAN
Roof Plan
Sheets
A-104 - ROOF PLAN
Elevations
Sheets
A-201 - EXTERIOR ELEVATIONS

File details come from the government source that posted it. Updated .