This request for proposal (RFP) Part I solicits proposals for the construction of a Deployable Airbase System - Facilities, Equipment, and Vehicles (DABS-FEV) storage complex in Campia Turzii, Romania. The U.S. Army Corps of Engineers intends to award a single firm fixed-price contract using a best value tradeoff acquisition method. Offerors are requested to submit non-price proposals only in response to this RFP Part I. Price proposals are not to be submitted at this time. The contract will be awarded based on evaluation factors including technical approach, past performance, and price. The anticipated period of performance is 365 days from notice to proceed.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E
US Army Corps of Engineers ®
CONTRACT NO.:
ISSUE DATE:
CONSTRUCTION
PACKAGE:
M
AR
K D
ES
C
R
IP
TI
O
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
M
M
L
K
J
H
G
F
E
D
C
B
A
NOT FOR
CONSTRUCTIO
N
G-001
CTAB-GEN
C O
VE
R
S H
EE
T
-C O
PE
R
TA
C
ÂM
P
IA
T U
R
ZI
I A
IR
B
AS
E, R
O M
AN
IA
EU
R
O P
E D
IS
TR
IC
T
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
IR
G
IN
IA
K.
O
LT
R . M
IS
FE
LD
T
J.
D
R
AK
E
R . S
TR
A
C C
AM
O
R E
SE
PT
EM
B
ER
, 2
W
2G B-
-D
-0
C O
N S
TR
U
C T
ED
I D
A
BS
/F
EV
S
TO
R
AG
E
EUROPE DISTRICT
W912GB-17-D-0001
SEPTEMBER 4, 2020
CÂMPIA TURZII AIR BASE, ROMANIA
CONSTRUCT EDI DABS/FEV STORAGE
S U
BM
IT
TA
L
SE
PT
EM
BE
R
, 2
SEAL-STAMPILA
VICINITY MAP - HARTA ZONA LOCATION MAP - PLAN DE INCADRARE
AREA MAP - PLAN DE SITUATIE
CTAB-GEN / GENERAL
PROJECT SITE
PROJECT SITE
PROJECT SITE
CTAB BUILDING ID TABLE
BLDG ID BUILDING NAME
CTAB-GEN GENERAL - NOT A SPECIFIC BUILDING
CTAB-SITE SITE DESIGN
CTAB-A ROLLING A
CTAB-B ROLLING B
CTAB-C PALLET STORAGE
CTAB-D CONTAINER STORAGE
CTAB-E FUEL VEHICLE FACILITY
CTAB-G VEHICLE MAINTENANCE
CTAB-H CENTRAL PLANT
CTAB-K SECURE ENTRY
CTAB-L PUMP HOUSE
CTAB - TABEL COD CLADIRI
COD NUME CLADIRE
CTAB-GEN GENERAL-NU PENTRU O CLADIRE ANUME
CTAB-SITE FORMA TERENULUI
CTAB-A UMIDITATE CONTROLATA
CTAB-B DEPOZITARE CURENTA
CTAB-C DEPOZITARE PE PALETI
CTAB-D DEPOZITARE IN CONTAINERE
CTAB-E CLADIRE CAMIOANE COMBUSTIBIL
CTAB-G VEHICULE MENTENANTA
CTAB-H CENTRALA TERMICA
CTAB-K ACCES SECURIZAT
CTAB-L CASA POMPE
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
M
M
L
K
J
H
G
F
E
D
C
B
A
NOT FOR
CONSTRUCTIO
N
G-002
CTAB-GEN
G
EN
ER
AL
IN
D
E X
O F
D R
AW
IN
G S
-L
IS
TA
D
E
PL
AN
SE
G
EN
ER
AL
A
C
ÂM
P
IA
T U
R
ZI
I A
IR
B
AS
E, R
O M
AN
IA
EU
R
O P
E D
IS
TR
IC
T
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
IR
G
IN
IA
K.
O
LT
R . M
IS
FE
LD
T
J.
D
R
AK
E
J.
D
R
AK
E
SE
PT
EM
B
ER
, 2
W
2G B-
-D
-0
C O
N S
TR
U
C T
ED
I D
A
BS
/F
EV
S
TO
R
AG
E
S U
BM
IT
TA
L
SE
PT
EM
BE
R
, 2
INDEX OF DRAWINGS - LISTA DE PLANSE
BLDG ID -
COD CLADIRE
SHEET NUMBER -
NUMAR PLANSA SHEET TITLE - TITLU PLANSA
CTAB-GEN E-001 ELECTRICAL NOTES AND LEGENDS
CTAB-GEN E-002 ELECTRICAL NOTES AND LEGENDS
CTAB-GEN E-003 ELECTRICAL NOTES AND LEGENDS
CTAB-GEN E-004 ELECTRICAL NOTES AND LEGENDS
CTAB-GEN E-500 ELECTRICAL DETAILS
CTAB-GEN E-501 ELECTRICAL DETAILS
CTAB-GEN E-502 ELECTRICAL DETAILS
CTAB-GEN E-504 LIGHTING DETAILS
CTAB-GEN E-506 LIGHTING DETAILS
CTAB-GEN E-507 LIGHTING DETAILS
CTAB-GEN E-600 LIGHTING SCHEDULES
CTAB-GEN E-603 LIGHTING CONTROLS
CTAB-GEN EY001 ELECTRONIC SECURTIY NOTES AND LEGENDS
CTAB-GEN EY002 NOTE GENERALE SI LEGENDA PENTRU SECURITATE ELECTRONICA ROMANIA
CTAB-GEN EY501 ELECTRONIC SECURITY DETAILS
CTAB-GEN EY502 ELECTRONIC SECURITY DETAILS
CTAB-GEN T-001 TELECOMMUNICATION NOTES AND LEGENDS
CTAB-GEN T-002 TELECOMMUNICATION NOTES AND LEGENDS
CTAB-GEN T-003 NOTE GENERALE SI LEGENDA TELECOMUNICATII ROMANIA
CTAB-GEN T-004 NOTE GENERALE SI LEGENDA TELECOMUNICATII ROMANIA
CTAB-GEN T-501 TELECOMMUNICATIONS DETAILS
CTAB-GEN T-502 TELECOMMUNICATIONS DETAILS
CTAB-GEN T-503 TELECOMMUNICATIONS DETAILS
CTAB-GEN T-504 TELECOMMUNICATIONS DETAILS
CTAB-GEN T-505 TELECOMMUNICATIONS DETAILS
CTAB-GEN T-601 TELECOMMUNICATIONS FIBER RISER DIAGRAM
CTAB-GEN T-602 TELECOMMUNICATIONS SCHEDULES
CTAB-GEN T-701 TELECOMMUNICATIONS BUTTERFLY BOX DETAILS
CTAB-GEN T-702 TELECOMMUNICATIONS BUTTERFLY BOX DETAILS
CTAB-GEN T-703 TELECOMMUNICATIONS BUTTERFLY BOX DETAILS
CTAB-GEN TZ601 CYBERSECURITY NETWORK ARCHITECTURE DIAGRAM
CTAB-GEN TZ602 CYBERSECURITY BMS FUNCTIONAL DIAGRAM
CTAB-GEN TZ603 CYBERSECURITY ESS FUNCTIONAL DIAGRAM
CTAB-GEN TZ604 CYBERSECURITY LIFE SAFETY FUNCTIONAL DIAGRAM
CTAB-GEN TZ605 CYBERSECURITY THREAT MODEL
INDEX OF DRAWINGS - LISTA DE PLANSE
BLDG ID -
COD CLADIRE
SHEET NUMBER -
NUMAR PLANSA SHEET TITLE - TITLU PLANSA
CTAB-GEN G-001 COVER SHEET - COPERTA
CTAB-GEN G-002 GENERAL INDEX OF DRAWINGS - LISTA DE PLANSE GENERALA
CTAB-GEN G-003 GENERAL NOTES AND LEGENDS - NOTE GENERALE SI LEGENDA
CTAB-GEN G-004 NOTE GENERALE SI LEGENDA
CTAB-GEN S-001 STRUCTURAL GENERAL NOTES
CTAB-GEN S-002 STRUCTURAL GENERAL NOTES
CTAB-GEN S-003 STRUCTURAL GENERAL NOTES AND ABBREVIATIONS
CTAB-GEN S-004 NOTE GENERALE STRUCTURA
CTAB-GEN S-005 NOTE GENERALE STRUCTURA
CTAB-GEN S-006 NOTE GENERALE STRUCTURA SI ABREVIERI
CTAB-GEN A-001 ARCHITECTURAL NOTES AND LEGENDS - NOTE SI LEGENDA DE ARHITECTURA
CTAB-GEN AE501 STANDARD ARCHITECTURAL DETAILS - DETALII STANDARD DE ARHITECTURA
CTAB-GEN AE502 STANDARD ARCHITECTURAL DETAILS - DETALII STANDARD DE ARHITECTURA
CTAB-GEN AE503 STANDARD ARCHITECTURAL DETAILS - DETALII STANDARD DE ARHITECTURA
CTAB-GEN AE601 STANDARD DOOR DETAILS - DETALII STANDARD DE USA
CTAB-GEN AE602 STANDARD DOOR DETAILS - DETALII STANDARD DE USA
CTAB-GEN AE603 STANDARD WINDOW DETAILS - DETALII STANDARD FERESTRE
CTAB-GEN FA001 FIRE ALARM COVER SHEET
CTAB-GEN FA002 COPERTA ALARMA DE INCENDIU
CTAB-GEN FA501 FIRE ALARM DETAILS
CTAB-GEN FX001 FIRE SUPPRESSION LEGEND AND NOTES
CTAB-GEN FX002 FIRE SUPPRESSION LEGEND AND NOTES
CTAB-GEN FX003 LEGENDE SI NOTE SISTEME STINGERE
CTAB-GEN FX004 LEGENDE SI NOTE SISTEME STINGERE
CTAB-GEN FX501 FIRE SUPPRESSION DETAILS
CTAB-GEN FX502 PLAN DETALII STINGERE INCENDIU
CTAB-GEN P-001 PLUMBING NOTES AND LEGENDS
CTAB-GEN P-002 NOTE INSTALATII SANITARE SI LEGENDE
CTAB-GEN P-501 PLUMBING DETAILS
CTAB-GEN P-502 PLUMBING DETAILS
CTAB-GEN P-601 PLUMBING SCHEDULES
CTAB-GEN P-602 PLUMBING SCHEDULES
CTAB-GEN P-603 PLUMBING SCHEDULES
CTAB-GEN M-001 GENERAL MECHANICAL AND HVAC NOTES
CTAB-GEN M-002 GENERAL MECHANICAL PIPING AND CONTROLS NOTES
CTAB-GEN M-003 MECHANICAL ABBREVIATIONS
CTAB-GEN M-004 MECHANICAL PIPING LEGEND
CTAB-GEN M-005 MECHANICAL DUCTWORK, CONTROLS AND MISCELLANEOUS LEGENDS
CTAB-GEN M-501 MECHANICAL DETAILS
CTAB-GEN M-502 MECHANICAL DETAILS
CTAB-GEN M-503 MECHANICAL DETAILS
CTAB-GEN M-504 MECHANICAL DETAILS
CTAB-GEN M-505 MECHANICAL DETAILS
CTAB-GEN M-506 MECHANICAL DETAILS
CTAB-GEN M-507 MECHANICAL DETAILS
CTAB-GEN M-508 MECHANICAL DETAILS
CTAB-GEN M-601 MECHANICAL SCHEDULES
CTAB-GEN M-602 MECHANICAL SCHEDULES
CTAB-GEN M-603 MECHANICAL SCHEDULES
CTAB-GEN M-604 MECHANICAL SCHEDULES
CTAB-GEN M-701 MECHANICAL CONTROLS
CTAB-GEN M-702 MECHANICAL CONTROLS
CTAB-GEN M-703 MECHANICAL CONTROLS
CTAB-GEN M-704 SCHEMA CONTROL CENTRALA TERMICA
CTAB-GEN M-901 MECHANICAL PIPING ONE LINE DIAGRAM
SEAL-STAMPILA
REFER TO EACH INDIVIDUAL
PACKAGE FOR AN INDEX OF
DRAWINGS OF THAT PACKAGE
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
T - TELECOMMUNICATION
DISCIPLINE MODIFIER
SYMBOLS LEGEND
A ---------------------
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECTURAL
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BS BOTH SIDES
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
REFER TO A/E/C CAD
STANDARD FOR SHEET
NUMBERING STANDARDS
SHEET NUMBER WITHIN SERIES
ABBREVIATIONS
DRAWING TITLEA1
A-101 SCALE
A-101
A1 A-101
A1 A-101
REFERENCE NUMBER
SHEETS WHERE REFERENCE IS CUT
PLAN
NORTH
PLAN NORTH
TRUE NORTH
ELEVATION NUMBER
ELEVATION DRAWN ON THIS SHEET
BUILDING ELEVATION REFERENCE
A1
A-101
A1 A-101
SECTION NUMBER
SECTION DRAWN ON THIS SHEET
BUILDING AND WALL SECTION REFERENCE
ELEVATION NUMBER
ELEVATION DRAWN ON THIS SHEET
INTERIOR ELEVATION REFERENCE
A1
B1D1
C1
DETAIL NUMBER
DETAIL DRAWN ON THIS SHEET
DETAIL REFERENCES
DETAIL NUMBER
DETAIL DRAWN ON THIS SHEET
ROOM
ROOM NAME AND
NUMBER REFERENCE
REFER TO A-601 FOR
ROOM NAME
TRANSLATIONS
1 WORK KEYNOTE
1 REVISION MARKER
INDEX OF DRAWINGS
A-101 ELEVATION NUMBER
ELEVATION DRAWN ON THIS SHEET
CASEWORK ELEVATION REFERENCE
A1
B1D1
C1
MATERIAL LEGEND
BATT INSULATION
BRICK
CONCRETE
CONCRETE
MASONRY UNITS
CONTINUOUS
BLOCKING
EARTH
FINISHED WOOD
GRAVEL
GYPUSM BOARD OR
SHEATHING
PLYWOOD
RIGID INSULATION
STEEL
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTAB CÂMPIA TURZII AIR BASE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FLOOR
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRCS FACILITY RELATED CONTROL
SYSTEMS
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR GRADE
GR FL GROUND FLOOR
GUT GUTTER
GYP GYPSUM
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HVLS HIGH-VOLUME, LOW-SPEED
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
M METER
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MM MILLIMETER
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTI
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND
RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEAL - STAMPILAANT
SM SQUARE METERS
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRL STRUCTURAL
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TELECOM TECOMMUNICATIONS
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TR TECOMMUNICATIONS ROOM
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UH UNIT HEATER
UHF ULTRA HIGH FREQUENCY
UL UNDERWRITERS' LABORATORY
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
V --------------------
V VOLTAGE, VENT, VALVE
VA VOLT-AMPERE
VAC VOLTS AC
VAR VOLT-AMPERE REACTIVE
VAV VARIABLE AIR VOLUME
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VD VOLUME DAMPER
VDC VOLTS DC
VEL VELOCITY
VEST. VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VHF VERY HIGH FREQUENCY
VIB VIBRATION
VIF VERIFY IN FIELD
VM VOLTMETER
VOL VOLUME
VR VAPOR RETARDER
VT VINYL TILE
VTR VENT THRU ROOF
W --------------------
W WEST, WATT
WA WAINSCOT
W.A.S. WASTE ACTIVATED SLUDGE
WB WIND BEAM
WC WATER CLOSET
WD WOOD
WDO WINDOW
WFD WATER FLOW DETECTOR
WG WATER GAGE
WH WALL HYDRANT
WHA WATER HAMMER ARRESTER
WHS WELDED HEAD STUD
WI WROUGHT IRON
WL WIND LOAD, WATER LINE
WM WATER METER
WP WORKING POINT, WEATHERPROOF
WPF WATERPROOFING
WS WATER SURFACE, WATERSTOP
WT WEIGHT
WTS WELDED THREADED STUD
WWF/WWR WELDED WIRE FABRIC/ WELDED
WIRE REINFORCEMENT
X --------------------
XARM CROSS ARM
XFMR TRANSFORMER
XFR TRANSFER
XMTR TRANSMITTER
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
M
M
L
K
J
H
G
F
E
D
C
B
A
NOT FOR
CONSTRUCTIO
N
G-003
CTAB-GEN
G
EN
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
S -N
O
TE
G
EN
ER
AL
E
SI
L
EG
EN
D
A
C
ÂM
P
IA
T U
R
ZI
I A
IR
B
AS
E, R
O M
AN
IA
EU
R
O P
E D
IS
TR
IC
T
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
IR
G
IN
IA
K.
O
LT
R . M
IS
FE
LD
T
J.
D
R
AK
E
R . S
TR
A
C C
AM
O
R E
SE
PT
EM
B
ER
, 2
W
2G B-
-D
-0
C O
N S
TR
U
C T
ED
I D
A
BS
/F
EV
S
TO
R
AG
E
S U
BM
IT
TA
L
SE
PT
EM
BE
R
, 2
SEAL -
STAMPILA
XX100
DISCIPLINA:
C - CIVIL
L - PEISAGISTICA
A - ARHITECTURA
M - MECANICE
E - ELECTRICE
P - SANITARE
s - STRUCTURA
T - TELECOMUNICTII
MODIFICATOR DE
SPECIALITATE
SIMBOLURI LEGENDE
A ---------------------
A/C AER CONDITIONAT
A/C UNIT UNITATE AER CONDITIONAT
A/E ARCHITECT / ENGINEER
AB SURUB DE ANCORARE
ACC ACCESIBIL
ACS SISTEMUL DE CONTROL AUTOMAT
ACS DR UȘĂ DE ACCES
ACS PNL PANOU DE ACCES
ACT TAVAN SUSPENDAT ACUSTIC
ADA AMERICANII CU DISABILITĂȚI ACT
ADMIN ADMINISTRARE
AFC DEASUPRA BLAT FINISAT
AFF DEASUPRA FINISAJ PARDOSEAL -
STAMPILAA
AFG DEASUPRA PANTEI FINISATE
AFS DEASUPRA PLANSEULUI FINISATE
AGGR AGREGAT
AHU UNITATEA DE MANIPULARE AIR
AIB BARIERA DE INFILTRARE A AERULUI
ALT ALTERNATIV
ALUM ALUMINIU
ANOD ANODIZAT
APC PLAFON SUSPENDAT ACUSTIC
APPROX APROXIMATIVE
AR ASA CERUT
ARCH ARHITECTURA
ASC DEASUPRA TAVANULUI SUSPENDAT
ASSY ASAMBLARE
ATC PLAFON CU PLĂCI ACUSTICE
AVG MEDIE
AW WWKK ARHITECTURAL LEMN
AWT TRATAMENTUL ACUSTIC DE
PERETE
B ---------------------
BALC BALCON
BB PLACA DE BAZA
BC BIBLIOTECA
BD PLACA
BDRY LIMITA
BFF SUB PARDOSEAL - STAMPILAA
FINITA
BHMA ASOCIATIA PRODUCATORILOR DE
PRODUSE PT CONSTRUCTII
BLDG CLADIRE
BLKG ZIDARIE
BLT IN INCASTRAT
BN SOCLU
BOS BAZA DE OTEL
BOT PARTE INFERIOARA
BP HARTIE DE CONSTRUCTII
BRKT SCOABA
BS AMBELE FETE
BSMT SUBSOL
BTWN INTRE
BUR ACOPERIS PREFABRICAT
C ---------------------
C CONC BETON TURNAT
CAB DULAP
CATW PODIUM
CAV CAVITATE
CBB PLACA PE BAZA DE CIMENT
CD DOCUMENTE CONSTRUCTIE
CDW APA RECE DE BAUT
CEM PLAS TENCUIALA DE CIMENT
CER CERAMIC
CF MOBILAT DE CONTRACTOR
CF/CI MOBILAT DE CONTRACTOR/
MONTAT DE CONTRACTOR
CFE ECHIPAMENT FURNIZAT DE
CONTRACTOR
CFLG PAZIE
CFM METRI CUBI PE MINUT
CFMF STRUCTURA METALICA FORMATA
LA RECE
CFS PICIOARE CUBICE PE SECUNDA
CG PROTECTIE DE COLT
CI FIER FORJAT
CIP TURNAT IN SITU
CJ ROST DE CONTROL
CL LINIE DE MIJLOC
CLG TAVAN
CLG DIFF GRILA TAVAN
CLG HT INALTIME PLAFON
CLL LINIE STALPI
CLO DEBARA
CLR CULOARE
CLRM SALA DE CLASA
CMU UNITATE DE ZIDARIE DIN BETON
CNDS CONDENSAT
CDR CITITOR DE CARDURI
CO CURATENIE
COL STALP
COMM COMUNICATII
CONC BETON
CONC FLR PLANSEU DE BETON
CONF CONFERINTA
CONSULTATI A/E/C CAD
STANDARD PENTRU
STANDARDUL DE
NUMEROTARE PLANSE
NUMAR DE PLANSA PE SERII
ABREVIERI
NUMELE PLANSEIA1
A-101 SCARA
A-101
A1 A-101
A1 A-101
NUMAR DE REFERINTA
PLANSA UNDE ESTE PREZENTATA
REFERINTA
PLAN
NORTH
NORDUL
PLANULUI
NORDUL
REAL
NUMAR ELEVATIE
ELEVATIE DESENATA PE ACEASTA PLANSA
REFERINTA ELEVATIE
A1
A-101
A1 A-101
NUMAR SECTIUNI
SECTIUNI DESENATE PE ACEASTA PLANSA
REFERINTA SECTIUNI
NUMAR ELEVATIE
ELEVATIE DESENATA PE ACEASTA PLANSA
REFERINTA ELEVATIE
A1
B1D1
C1
NUMAR DETALIU
DETALIU DESENAT PE ACEASTA PLANSA
DETALIU REFERINTA
NUMAR DETALIU
DETALIU DESENAT PE ACEASTA PLANSA
CAMERA
NUMAR CAMERA SI
NUMAR REFERINTA
REFERINTA LA PLANSA
A-601 PENTRU
TRADUCEREA TITLULUI
PLANSEI
1 NOTA DE LUCRU
1 MARKER REVIZIE
NUMAR PLANSA
A-101 NUMAR ELEVATIE
ELEVATIE DESENATA PE ACEASTA PLANSA
REFERINTA ELEVATIE
A1
B1D1
C1
LEGENDA MATERIALE
SALTEA IZOLATIE
CARAMIDA
BETON
CARAMIDA DE
BETON
BLOCARE CONTINUA
PAMANT
LEMN FINISAT
PIETRIS
PLACARE GIPS
CARTON
PLACAJ LEMN
IZOLARE RIGIDA
OTEL
CONT CONTINUU
COORD COORDONATE
CORR CORIDOR
CP CONDUCTA BETON
CPT COVOR
CR CAMERA CONTROL
CS PIATRA TURNATA
CSWK CARCASA
CT PLACA CERAMICA
CTAB CÂMPIA TURZII BAZA DE AER
CTB BAZA PLACA CERAMICA
CTF PARDOSEAL - STAMPILAA
CERAMICA
CTR CENTRU
CU FT PICIOR CUBIC
CW TAMPLARIE FEREASTRA
D ---------------------
D ADANCIME
DBL DUBLU
DEMO DEMOLARE
DEPT DEPARTAMENT
DET DETALIU
DIA DIAMETRU
DIR DIRECTIE
DIST DISTANTA
DOC DOCUMENT
DR USA
DS BURLAN
E ---------------------
EA FIECARE
EF EFIECARE FATA
EIFS TERMOSISTEM
EJ ROST DE DILATARE
ES FIECARE PARTE
EL ELEVATIE
ELEC ELECTRIC
ELEV LIFT
ENTR INTRARE
EPS PLACA POLISTIREN EXPANDAT
EQ EGAL
EWC RACITOR ELECTRIC PENTRU APA
EXP APARENT (EXPUS)
EXT EXTERIOR
EXT STINGATOR
EXT GR PANTA EXTERIOARA
F ---------------------
FA ALARMA INCENDIU
FAAP PANOU ALARMARE INCENDIU
FAS BD PAZIE
FC BRK CARAMIDA APARENTA
FCO CURATARE PARDOSEAL -
STAMPILAA
FD SIFON DE PARDOSEAL - STAMPILAA
FDTN FOUNDATIE
FE STINGATOR DE INCENDIU
FEC DULAP STINGATOR DE INCENDIU
FED FEDERAL
FF PARDOSEAL - STAMPILAA FINISATA
FF INSUL TERMOIZOLATIE CASERATA
FGL FIBRA DE STICLA
FH FURTUN HIDRANT
FHP PARTITIE PANA IN TAVAN
FIN FINISAJ
FIXT ACCESORIU
FLDG PLIABIL
FLEX FLEXIBIL
FLG FINISAJ PARDOSEAL - STAMPILAA
FLMT MONTAT LA FATA
FLR PARDOSEAL - STAMPILAA
FM MUTUAL DIN FABRICA
FOC FATA BETON
FOM FATA ZIDARIE
FR REZISTENT LA FOC
FRCS SISTEME DE CONTROL LEGATE CU
INSTALATII
FRG GIPSCARTON RANFORSAT CU
FIBRA
FRMG STRUCTURA USOARA
FRP PLASTIC CU FIBRA DE STICLA
FRTW FIRE LEMN IGNIFUGAT
FS SPECIFICATIE FEDERALA
FSTNR ELEMENT DE FIXARE
FTG BAZA
FWC TAPET TEXTIL
G ---------------------
G GAZE NATURALE
GALV GALVANIZAT
GB BARA DE SPRIJIN
GFCI FURNIZAT DE GUVERN
INSTALAT DE CONTRACTOR
GFGI FURNIZAT DE GUVERN
INSTALAT DE GUVERN
GFRG GIPS RANFORSAT CU FIBRA
DE STICLA
GLZ STICLA
GR PANTA
GR FL PARTER
GUT JGHEAB
GYP GIPS
H ---------------------
HB FURTUN BIBB
HDPE POLIETILENA DENSITATE RIDICATA
HDW COMPONENTE
HDWD PLACAJ
HEPA FILTRU DE AER DE EFICIENTA
RIDICATA
HM PROFILE METALICE
HMD USA DIN PROFILE METALICE
HORIZ ORIZONTAL
HT INALTIME
HVLS VOLUM RIDICAT, VITEZA MICA
HYDR HIDRAULIC
I ---------------------
IBC CODUL INTERNATIONAL PT
CONSTRUCTII
INSUL TERMOIZOLATIE
INT INTERIOR
ILO IN LOC DE
J ---------------------
JAN INGRIJITOR
K ---------------------
KPD TASTATURA
KIT BUCATARIE
KPL PLACA PROTECTIE USA
L ---------------------
LAM LAMINAT
LAV LAVOAR
LBR CHERESTEA
LBS POUND
LDG PODEST
LF PICIOR LINIAR (FOOT)
LIB BIBLIOTECA
LIN LINEAR
LKR VESTIAR
LOC LOCATIE
LT LUMINA
LVDR USA JALUZELE
LVR JALUZELE
M ---------------------
M METRU
MACH RM CAMERA TEHICA
MATL MATERIAL
MAX MAXIMUM
MC CONTINUT DE UMEZEALA
MD PARODEALA METALICA
MECH MECANICE
MEMB MEMBRANA
MF MILL FINISH
MFR PRODUCATOR
MID MIJLOC
MIL STD STANDARD MILITAR
MIN MINIMUM, MINUT
MIRR OGLINDA
MISC DIVERSE
MLDG MOLDING (MOULDING)
MM MILLIMETRU
MO GOL ZIDARIE
MOD MODIFICA
MB BARIERA ANTI UMEZEALA
MTG MONTAJ
MTL METAL
MVBL MOBIL
MWP MEMBRANA HIDROIZOLANTA
N ---------------------
N NORD
NA NU SE APLICA
NFPA ASOCIATIA NATIONALA DE
PROTECTIE LA FOC
NIC NU E IN CONTRACT
NO NUMAR
NOM NOMINAL
NP NE VOPSIT
NRC ATENUANT FONIC
O -------------------
OA PER TOTAL
OC PE CENTRU
OD DIAMETRU EXTERIOR
OFD PREAPLIN
OFF BIROU
OGL STICLA OPACA
OPH MANA OPUSA
OPNG DESCHIDERE
OPP OPUS
OPQ OPAC
OWSJ OPEN GRINDA CU ZABRELE
OPR OPERABIL
ORD PREAPLIN DE ACOPERIS
ORIG ORIGINAL
P --------------------
PA ADRESARE PUBLICA
PAR PARAPET
PAT PATTERN
PB CAMIND DE TRAGERE
PBD PLACA AGLOMERATA
PCC BETON PREFABRICAT
PCF POUNDS PE PICIOR CUB
PCT PROCENT
PERF PERFORAT
PERIM PERIMETRU
PH FAZA
PIL PILASTRU
PL LIMITA DE PROPRIETATE
PL GL PLACA DE STICLA
PLAM LAMINAT PLASTIC
PLAS TENCUIALA
PLBG SANITARE
PLG PILING
PLYWD PLACAJ LEMN
PNL PANEL
PP PL PLACA DE IMPINGERE/TRAGERE
PR PERECHE
PRCST PRETURNAT
PRKG PARCARE
PS CONC BETON PRETENSIONAT
PSF POUNDS PE PICIOR PATRAT
PSI POUNDS INCH PATRAT
PT TRATAT PRIN PRESIUNE
PTD DISPENSER PROSOAPE
HARTIE
PTDR DISPENSER PROSOAPE
HARTIE SI RECEPTOR
PTN PARTITIE
PWR PUTERE
Q --------------------
QT PLACA DIN CARIERA
QTY CANTITATE
R --------------------
RB BAZA RESILIENTĂ
RBM ZIDARIE ARMATA DE CARAMIDA
RBR CAUCIUC
RC BETON ARMAT
RCP PLAN PLAFOANE
RD RECEPTOR DE TERASA
RDG INS TERMOIZOLATIE RIGIDA
REC MONTAJ INGROPAT
REC ROOM CAMERA RELAXARE
REF REFERINTA
REM DETASABIL
REP REPARATIE
REPL INLOCUIRE
REQ NECESITA
REQD NECESAR
RESIL RESILIENT
REST TOALETA
RF PARDOSEAL - STAMPILAA
RESILIENTA
RFG ACOPERIS
RH HASURA ACOPERIS
RHR INTOARCERE LA DREAPTA
RL SCARA DE ACOPERIS
RLG BALUSTRADA
RM CAMERA
RO GOL LA ROSU
RSD USA TIP RULOU DIN OTEL
RV AERISIRE ACOPERIS
RVL DEZVALUIE
S --------------------
SB BLOC DE STROPI
SCHED PROGRAM
SD DETECTOR DE FUM
SF PICIOR PATRAT
SFTWD LEMN DE ESENTA MOALE
SGL SINGUR
SHT MTL FLASH CAPAC (PAZIE) METALIC
SHTHG TABLA
SHV RAFTURI
SIM SIMILAR
SJ ROST DESCHIS
SKLT LUMINATOR
SLNT SIGILANT
SM METRI PATRATI
SMK FUM
SMLS FARA ROST
SP EL ELEVATIE PUNCTUALA
SPEC SPECIFICATIE
SQ PATRAT
SQ IN INCH PATRAT
SQ YD CURTE PATRATA
SST OTEL INOXIDABIL
ST SCARI
STD STANDARD
STL JST BRAT DE OTEL
STL RF DK ACOPERIS METALIC
STOR DEPOZITARE
STR LONJEROANE
STRB/HRN COS
STRL STRUCTURAL
SUB FL SUBSTRAT PARDOSELA
SV FOAIE VINYL
SW TROTUAR
T --------------------
T TREAPTA
T/S CADA / DUS
TC TERRA COTTA
TD SANT DE SCURGERE
TEL TELEFON
TELECOM TECOMUNICATII
TEMP TEMPORAR
TER TERRAZZO
TFF PARTEA SUPERIOARA A
FINISAJULUI DE PARDOSELA
THK GROSIME
TK BD TACKBOARD
TMPD GL STICLA CALITA
TN NORD ADEVARAT
TOF PARTEA SUPERIOARA A BAZEI
TOM PARTEA SUPERIOARA A ZIDARIEI
TOP PARTEA SUPERIOARA PARAPET
TOPO TOPOGRAFIE
TOS PARTEA SUPERIOARA A PLACII
TR CAMERA TECOMUNICATII
TRANS RIGLA
TRTD TRATAT
TV TELEVIZIUNE
TYP TIPIC
U --------------------
UH UNITATE DE CLIMATIZARE
UHF FRECVENTA FOARTE RIDICATA
UL UNDERWRITERS' LABORATOR
UNO DACA NU E SPECIFICAT ALTFEL
UPS SURSA CURENT INTANGIBILA
V --------------------
V VOLTAJ, VENT, VALVA
VA VOLT-AMPERE
VAC VOLTI, AC
VAR VOLT-AMPERE REACTIV
VAV VOLUME VARIABL AER
VB BARIERA DE VAPORI
VCT PLACA VINIL
VD CLAPET DE VOLUM
VDC VOLTI DC
VEL VITEZA
VEST. VESTIBUL
VFD DRIVE DE FRECVENTA VARIABILA
VHF FRECVENTA FOARTE INALTA
VIB VIBRATIE
VIF VERIFICAT IN TEREN
VM CONTOAR DE VOLUM
VOL VOLUM
VR RETARDATOR DE VAPORI
VT PLACA VINYL
VTR VENTILATIE PRIN ACOPERIS
W --------------------
W VEST, WATT
WA WAINSCOT
W.A.S. DESEURI ACTIVATE
WB WIND BEAM
WC REZERVOR APA
WD LEMN
WDO FEREASTRA
WFD DETECTOR SCURGERI APA
WG APOMETRU
WH HIDRANT DE PERETE
WHA HAMMER ARRESTER APA
WHS MONTANT SUDAT
WI FIER FORJAT
WL INCARCARE DIN VANT, LINIA APEI
WM APOMETRU
WP REZISTENT LA APA
WPF IZOLARE LA APA
WS SUPRAFATA APA, WATERSTOP
WT GREUTATE (MASA)
WTS TIJA FILETATA SUDATA
WWF/WWR PLASA SUDATA/ARMATURA
X --------------------
XARM INCRUCISAT
XFMR TRANSFORMER
XFR TRANSFER
XMTR TRANSMITATOR
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
M
M
L
K
J
H
G
F
E
D
C
B
A
NOT FOR
CONSTRUCTIO
N
G-004
CTAB-GEN
N O
TE
G
EN
ER
AL
E
SI
L
EG
EN
D A
C
ÂM
P
IA
T U
R
ZI
I A
IR
B
AS
E, R
O M
AN
IA
EU
R
O P
E D
IS
TR
IC
T
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
IR
G
IN
IA
K.
O
LT
M . O
LT
EA
N U
J.
D
R
AK
E
M . O
LT
EA
N U
SE
PT
EM
B
ER
, 2
W
2G B-
-D
-0
C O
N S
TR
U
C T
ED
I D
A
BS
/F
EV
S
TO
R
AG
E
S U
BM
IT
TA
L
SE
PT
EM
BE
R
, 2
SEAL-STAMPILA
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S E
U R
O P
E D
IS
T
R
IC
T D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
S-001
CTAB-GEN
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
C A
M P
IA
T
U R
Z
II
A
IR
B
A S
E R
O M
A N
IA
W S
P B
E N
D
IX
R D
S T
E
V
IR
G
IN
IA
B
E A
C H
V
IR
G
IN
IA
M .W
IL
D
E
A .C
A R
T E
R
J .D
R A
K E
S .C
H
IA
N G
S E
P T
E M
B E
R
T H
W G
B -1
-D
-0
C O
N S
T R
U C
T E
D I D
A B
S /F
E V
S T
O R
A G
E
S
U B
M
IT
T A
L S
E P
T E
M B
E R
T
H
CODES AND STANDARDS
STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FOLLOWING:
1. U.S. STRUCTURAL CODES AND STANDARDS
A. UFC 1-202-01 – UNIFIED FACILITIES CRITERIA HOST NATION FACILITIES IN
SUPPORT OF MILITARY OPERATIONS
B. UFC 3-301-01 – UNIFIED FACILITIES CRITERIA STRUCTURAL ENGINEERING
C. IBC 2015 – INTERNATIONAL CODE COUNCIL, INTERNATIONAL BUILDING
CODE 2015
D. ASCE 7-10 - AMERICAN SOCIETY OF CIVIL ENGINEERS, 2010, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
E. AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION, MANUAL OF
STEEL CONSTRUCTION, FOURTEENTH EDITION
F. ACI 318-14 - AMERICAN CONCRETE INSTITUTE, 2014, BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY
G. ACI 530-11, AMERICAN CONCRETE INSTITUTE, 2011, BUILDING CODE
REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES
H. ANSI/SDC RD-2010, STEEL DECK INSTITUTE, 2010, STANDARD FOR STEEL
ROOF DECK.
I. SJI-COSP-2010, STEEL JOIST INSTITUTE, 2010, CODE OF STANDARD
PRACTICE FOR STEEL JOISTS AND JOIST GIRDERS
J. MNL-120-17, PRECAST CONCRETE INSTITUTE, DESIGN HANDBOOK, 8TH
EDITION.
2. EUROPEAN STRUCTURAL CODES AND STANDARDS
A. EUROCODE 0: BASIS OF STRUCTURAL DESIGN (SR EN 1990:2004 & SR EN
1990:2004/NA:2006)
B. EUROCODE 1: ACTIONS ON STRUCTURES (SR EN 1991-1-1:2004 – SR EN
1991-1-7:2007 & SR EN 1991-1-1:2004/NA:2006 – SR EN
1991-1-7:2007/NB:2011)
C. EUROCODE 2: DESIGN OF CONCRETE STRUCTURES (SR EN 1992-1-1:2004,
SR EN 1992-1-2:2006, SR EN 1992-3:2006 & SR EN 1992-1-1:2004/NB:2008, SR
EN 1992-1-2:2006/NA:2009, SR EN 1992-3:2006/NA:2008)
D. EUROCODE 3: DESIGN OF STEEL STRUCTURES (SR EN 1993-1-1:2006 – SR
EN 1993-1-12:2007 & SR EN 1993-1-1:2006/NA:2008 – SR EN
1993-1-12:2007/NA2012)
E. EUROCODE 4: DESIGN OF COMPOSITE STRUCTURES (SR EN 1994-1-1:2004,
SR EN 1994-1-2:2006 & SR EN 1994-1-1:2004/NB:2008, SR EN
1994-1-2:2006/NB:2008)
F. EUROCODE 7: GEOTECHNICAL DESIGN (SR EN 1997-1:2004 & SR EN
1994-1:2004/ NB:2007)
3. ROMANIAN STRUCTURAL STANDARDS:
A. P 100-1/2013 (ERRATA 2019): SEISMIC DESIGN;
B. CR 0/2012 DESIGN CODE. BASIS OF STRUCTURAL DESIGN;
C. CR 1-1-3/2012 DESIGN CODE: EVALUATION OF SNOW ACTION ON
STRUCTURES;
D. CR 1-1-4/2012 DESIGN CODE: EVALUATION OF WIND ACTION ON
STRUCTURES;
E. NP 112/2014 DESIGN OF SHALLOW FOUNDATIONS;
F. NE 012-1/2007 NORMATIVE FOR PRODUCTION AND EXECUTION OF
CONCRETE, REINFORCED CONCRETE AND POST-TENSIONED CONCRETE.
PART 1: CONCRETE PRODUCTION;
G. NE 012-2/2010 NORMATIVE FOR PRODUCTION AND EXECUTION OF
CONCRETE, REINFORCED CONCRETE AND POST-TENSIONED CONCRETE.
PART 2: EXECUTION OF CONCRETE WORKS;
H. NE 020/2003 DESIGN OF COMPOSITE SLABS;
I. SR EN 206+A1:2017 CONCRETE: SPECIFICATIONS, PERFORMANCE,
PRODUCTION AND CONFORMITY;
J. ST 009/2011 TECHNICAL SPECIFICATIONS FOR CONCRETE
REINFORCEMENT;
K. NP 042/2000 DESIGN OF STEEL STRUCTURAL ELEMENTS AND
CONNECTIONS;
L. C 169/1988 NORMATIVE FOR EXECUTION OF EXCAVATION WORKS FOR
FOUNDATIONS OF CIVIL AND INDUSTRIAL BUILDINGS.
4. ROMANIAN DESIGN LOADS
ROOF LOADS
ROOF LIVE LOAD 1.0 KN/M2
ROOF SUPERIMPOSED DEAD LOAD 0.05 KN/M2
SNOW LOAD
GROUND SNOW LOAD, SK 1.5 KN.M2
EXPOSURE FACTOR, CE 0.8 ROOF
THERMAL FACTOR, CT 1.0
WIND LOADS
WIND PRESSURE, WE 0.5 KN/M2
IMPORTANCE-EXPOSURE FACTOR, YLW 1.15
SEISMIC LOAD
GROUND ACCELERATION, AG 0.10G
IMPORTANCE CLASS, I 1.4
CONTROL PERIOD, TC 0.7
GENERAL
1. THESE DRAWINGS ARE INCOMPLETE UNLESS ACCOMPANIED BY THE
CONTRACT SPECIFICATIONS.
2. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ALL
OTHER DRAWINGS. CONTRACTOR SHALL COORDINATE THE WORK OF OTHER
TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS FOR SLEEVES,
INSERTS, HOLES, HANGERS AND ANCHORS.
3. THE GENERAL SCOPE OF THE STRUCTURAL WORK INCLUDES THE
FOLLOWING:
WAREHOUSE A – 164 M LONG, 40 M WIDE, 4.8 M AT EAVE HEIGHT. IT IS A
SINGLE-STORY STEEL FRAMED ROOF SUPPORTED BY PRECAST CONCRETE
COLUMNS, ON SHALLOW FOUNDATION. THE GABLE ROOF STRUCTURE IS
STEEL DECK ON OPEN WEB STEEL JOISTS SUPPORTED BY OPEN WEB
STEEL GIRDERS THAT BEAR ON PRECAST COLUMNS. LATERAL LOAD
RESISTING SYSTEM IN BOTH TRANSLATIONAL AND LONGITUDINAL
DIRECTIONS ARE RELYING ON THE STIFFNESS OF FREE-STANDING
COLUMNS. GROUND FLOOR IS SLAB-ON-GRADE, 200 mm THICK CONCRETE.
WAREHOUSE B – 164 M LONG, 40 M WIDE, 4.8 M AT EAVE HEIGHT.
STRUCTURAL SYSTEM IS THE SAME AS BUILDING A.
WAREHOUSE C – 88.5 M LONG, 30 M WIDE, 4.8 M AT EAVE HEIGHT.
STRUCTURAL SYSTEM IS THE SAME AS BUILDING A.
WAREHOUSE D – 95.5 M LONG, 29 M WIDE, 14 M AT EAVE HEIGHT. THIS
BUILDING CONTAINS TWO ROWS OF BRIDGE CRANE, EACH RUNNING FULL
LENGTH OF THE BUILDING. THE CRANE GIRDER AND ITS LATERAL
SUPPORT RELY ON THE FREE-STANDING CONCRETE COLUMNS. THE
BUILDING LATERAL LOAD SYSTEM IS THE SAME AS BUILDING A. SO IS THE
FLOOR SYSTEM.
THE GABLE ROOF STRUCTURE IS STEEL DECK ON STEAL BEAMS
SUPPORTED BY STEEL TRUSS GIRDERS WHICH ARE CONNECTED TO WIDE
FLANGE STEEL COLUMNS STUB FROM TOP OF CONCRETE COLUMN AT
CRANE RAIL ELEVATION. IN THE SHORT DIRECTION, LATERAL LOAD
RESISTING SYSTEM AT THE UPPER PART IS MOMENT FRAMES BETWEEN
THE GIRDER TRUSSES AND COLUMNS; IN THE LONG DIRECTION IS
CONTINUOUS MOMENT FRAMED BEAMS WHICH ALSO RESIST THE
CLADDING WIND/SEISMIC FORCES.
WAREHOUSE E – 50.5 M LONG, 32 M WIDE, 6.3 M AT EAVE HEIGHT.
STRUCTURAL SYSTEM IS THE SAME AS BUILDING A.
WAREHOUSE G – 94 M LONG, 20 M WIDE, 3.4 M (LOW BAY), 6.5 M (HIGH BAY)
AT EAVE HEIGHT. STRUCTURAL SYSTEM IS THE SAME AS BUILDING A.
WAREHOUSE H – 26 M LONG, 8 M WIDE, 4.8 M AT EAVE HEIGHT. THE ROOF
STRUCTURE IS LOW SLOPED. THE FRAMING SYSTEM IS THE SAME AS
BUILDING A.
WAREHOUSE L – 13 M LONG, 13 M WIDE, 5.2 M AT EAVE HEIGHT. THE ROOF
STRUCTURE IS LOW SLOPED. THE FRAMING SYSTEM IS THE SAME AS
BUILDING A.
4. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO
THE OWNER OR THEIR REPRESENTATIVE PRIOR TO BEGINNING WORK IN
AREAS THAT WILL BE AFFECTED.
5. DETAILS ENTITLED OR NOTED AS 'TYPICAL' APPLY NOT ONLY WHERE
SPECIFICALLY INDICATED OR REFERENCED, BUT ALSO IN ALL OTHER CASES
WHERE THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE.
6. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS xxxx (mm) IN REFERENCE TO DATUM ELEVATION 0 (mm). REFER TO CIVIL DRAWINGS FOR
SURVEY ELEVATION CORRESPONDING TO DATUM OF EACH BUILDING.
7. VERIFY AND COORDINATE ALL DIMENSIONS, ELEVATIONS, ETC. NECESSARY
FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE WORK. TAKE ALL
MEASUREMENTS NECESSARY FOR PROPER FABRICATION, ALIGNMENT, AND
INSTALLATION OF STRUCTURAL MEMBERS AND COMPONENTS.
8. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP
DRAWINGS UNDER ANY CIRCUMSTANCE.
9. ALL ITEMS SHOWN IN THESE DRAWINGS ARE NEW CONSTRUCTION UNLESS
SPECIFICALLY NOTED OTHERWISE.
LOAD CRITERIA PER ASCE 7-10
1. ROOF LOADS
A. ROOF LIVE LOAD 1.0 kN PSM (20 PSF) B. ROOF SUPERIMPOSED DEAD LOAD 0.5 kN PSM (10 PSF) AS ROOFING.
SUBJECT TO CHANGE BASED ON FINAL DESIGN OF ROOF
C. SNOW LOAD
• GROUND SNOW LOAD, PG 1.5 kN PSM (25 PSF)
• EXPOSURE FACTOR, CE 1.0
• ROOF THERMAL FACTOR, CT 1.0
• IMPORTANCE FACTOR, Is 1.0
• BALANCE DESIGN SNOW LOAD 1.0 kN (21 PSF) EFFECT OF SNOW
DRIFT IS ACCOUNTED FOR IN THE DESIGN PROCESS
D. UNDERHUNG LOAD 0.25 KPA (5 PSF) TO ROOF FRAMING BOTTOM CHORD
FOR MEP ELEMENTS; CONCENTRATED LOAD IS CONSIDERED IN DETAILED
DESIGN.
2. WIND LOADS
• BASIC WIND SPEED, V 35.8 m/s (80 MPH) (THREE SECOND GUST)
• EXPOSURE C
• RISK CATEGORY II
• INTERNAL PRESSURE COEFF: GCPI +/-0.18 (ENCLOSED BUILDING)
• WIND PRESSURES VARY PER SPECIFIC BUILDING SURFACES AND
PURPOSE OF DESIGN. DETAILS ARE REFLECTED IN DESIGN
CALCULATIONS.
3. SEISMIC LOAD PARAMETERS
• MAPPED SHORT PERIOD SPECTRAL RESPONSE ACCELERATION,
SS=110%G
• MAPPED 1-SEC PERIOD SPECTRAL RESPONSE ACCELERATION, S1=52%G
• SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCELERATION, SDS=0.777
• 1-SEC PERIOD DESIGN SPECTRAL RESPONSE ACCELERATION, SD1=0.52
• RISK CATEGORY II
• SEISMIC DESIGN CATEGORY D
• SITE CLASS D
• BASIC STRUCTURAL SYSTEM IS CANTILEVERED COLUMN SYSTEM
• BASIC SEISMIC-FORCE-RESISTING SYSTEM IS SPECIAL REINFORCED
CONCRETE MOMENT FRAMES
• RESPONSE MODIFICATION FACTOR, R = 2.5
• DEFLECTION AMPLIFICATION FACTOR, CD = 2.5
• IMPORTANCE FACTOR IE = 1.0
• SEISMIC RESPONSE COEFFICIENT CS = 0.311
• ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
• DESIGN BASE SHEAR VS = CS X W (WEIGHT/MASS OF BUILDING)
FOUNDATION
1. SHALLOW FOUNDATION DESIGN IS BASED ON PRELIMINARY GEOTECHNICAL
REPORT BY WOOD E&IS GMBH IN FRANKFURT, GERMANY, FEB. 2020.
2. BOTTOM OF FOOTING MUST BE BELOW THE FROST PENETRATION LINE OF
1100 mm (3 FT-8 IN).
3. THE DESIGN ALLOWABLE NET SOIL PRESSURE IS 300 KPA (6200 PSF) UNDER
STATIC (DEAD AND SNOW) LOAD; 400 KPA (8200 PSF) UNDER TRANSIENT
(WIND AND SEISMIC) LOAD.
4. BOTTOM OF FOOTING REST ON VIRGIN GRAVEL OR COARSE SAND, OR
COMPACTED STRUCTURAL FILL. A COMPETENT SUBGRADE IS BUILT UP TO
BOTTOM OF FOOTING ELEVATION SHOWN ON DRAWING. BOTTOM OF
FOUNDATION IS NOT PERMITTED TO BE LOWERED FROM DESIGN ELEVATION
SHOWN ON DRAWING.
5. FOUNDATION CONSTRUCTION MUST NOT COMMENCE UNTIL GEOTECHNICAL
INVESTIGATION IS COMPLETE AND THE GEOTECHNICAL REPORT IS
OFFICIALLY SUBMITTED TO THE OWNER.
6. ALL COHESIVE OR UNSUITABLE SOIL MUST BE REMOVED, REPLACED WITH
WELL-COMPACTED STRUCTURAL FILL TO THE EXPOSED ROCK BED OR
GRANULAR SOIL.
7. IF UNSUITABLE MATERIAL IS ENCOUNTERED AT THE BASE OF FOUNDATION
ELEVATION, UNDERCUT THE UNSUITABLE SOIL TO A DEPTH APPROVED BY
THE GEOTECHNICAL ENGINEER, AND REPLACE WITH WELL-COMPACTED
STRUCTURAL FILL. COMPACTION DENSITY MUST REACH MINIMUM 95% SR-EN
13286-2.
8. SUBGRADE PREPARATION MUST BE INSPECTED AND APPROVED BY THE
GEOTECHNICAL ENGINEER.
9. NO FOUNDATION CONCRETE SHALL BE INSTALLED UNTIL ALL FOUNDATION
WORK HAS BEEN COORDINATED WITH UNDERGROUND UTILITIES. REPORT TO
OWNER FOR ANY CONFLICT BETWEEN FOUNDATION AND UTILITY LINES.
OBTAIN OWNER APPROVED SOLUTION BEFORE PROCEEDING.
10. TO MINIMIZE WEATHERING, THE LAST 150 MM OF EXCAVATION FOR ALL
FOOTINGS SHALL BE MADE IMMEDIATELY PRIOR TO PLACEMENT OF
FOOTINGS.
CONCRETE
1. ALL CONCRETE HEREIN IS NORMAL WEIGHT, CAST-IN-PLACE. CONCRETE WITH
COMPRESSIVE STRENGTH AS FOLLOWS:
A. FOUNDATION WALLS AND COLUMNS C25/30 Fck = 25 N/mm2 (f'c = 3,600 psi) B. SLAB-ON-GRADE C30/37 Fck = 30 N/mm2 (f'c = 4,300 psi) C. INSIDE BUILDING NOT SPECIFIED C25/20 Fck = 25 N/mm2 (f'c = 3,600 psi)
2. REINFORCING BARS:
BST500 (FY=72 ksi), DEFORMED SURFACE
3. REINFORCEMENT SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH
SR EN 1992-1-1 AND NE 012-2.
4. CONTINUOUS REINFORCING IN WALLS AND SLABS MAY BE SPLICED, AS REQUIRED,
PROVIDING BARS ARE OF THE LONGEST PRACTICABLE LENGTH AND SPLICES ARE
SHOWN ON REINFORCING SHOP DRAWINGS. WHEREVER POSSIBLE, SPLICES SHALL
BE STAGGERED.
5. PROVIDE CONCRETE COVER FOR REINFORCING AS SPECIFIED BELOW. IN NO CASE
SHALL REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF SR EN
1992-1--1, U.N.O. IN DRAWINGS.
CONCRETE DEPOSITED AGAINST THE GROUND 75 mm (3") CONCRETE EXPOSED TO EARTH OR WEATHER 50 mm (2") SLABS AND WALLS 35 mm (1 ½”)
6. PROVIDE DOWELS TO MATCH REINFORCEMENT SIZE AND SPACING INDICATED FOR
ALL STRUCTURAL ELEMENTS, UNO.
7. MAJOR CONSTRUCTION JOINTS, IF ANY, ARE SHOWN ON THE DRAWINGS.
INTERMEDIATE JOINTS IN WALLS, SLABS, AND FLOOR FRAMING ARE NOT SHOWN.
CONSTRUCTION JOINTS MAY BE ADDED, OMITTED OR RELOCATED IF PROPERLY
DETAILED ON SHOP DRAWINGS AND APPROVED BY THE EOR.
8. SEE ARCHITECTURAL, MECHANICAL, AND OTHER DISCIPLINE DRAWINGS FOR
LOCATIONS OF OPENINGS AND SLEEVES IN CONCRETE WALLS AND SUPPORTED
FLOORS. SPREAD REINFORCEMENT AT OPENINGS AND SLEEVES, UNO. DO NOT CUT
REINFORCEMENT. SEE TYPICAL REINFORCEMENT DETAILS FOR OPENINGS IN SLABS
AND WALLS FOR ADDITIONAL REQUIREMENTS.
9. WALL FOUNDATIONS SHALL BE CAST IN PANELS NOT TO EXCEED 10 M (30 FT) LENGTH
IN ONE PLACEMENT.
10. PROVIDE WATERSTOPS IN ALL CONSTRUCTION JOINTS AT OR BELOW GRADE.
PROVIDE WATERSTOPS IN EXPANSION JOINTS AND CONSTRUCTION JOINTS OF
LIQUID-CONTAINING STRUCTURES AND WHERE REQUIRED TO PREVENT
INFILTRATION OF GROUND WATER.
11. DEPRESS FLOOR SLABS AS REQUIRED; SEE ARCHITECTURAL DRAWINGS FOR
LOCATION AND DEPTH OF DEPRESSED AREAS.
12. CHAMFER EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES 20 mm (3/4”), U.N.O.
13. EXTERIOR CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED.
14. REINFORCING STEEL SHOP DRAWING AND CONCRETE FORMWORK DESIGN ARE
PRODUCED BY THE CONSTRUCTION CONTRACTOR. REFER TO SPEC SECTION
03.30.00 FOR DETAILS REGARDING REBAR SHOP DRAWING PRODUCTION APPROVAL
15. THE ABOVE DOES NOT APPLY TO PRECAST CONCRETE PANELS.
N O T F
O R
C
N S
TR
U C
TIO
N
N U S
U N T P
E N
TR
U
E
XE
C
TIE
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S E
U R
O P
E D
IS
T
R
IC
T D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
S-002
CTAB-GEN
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
C A
M P
IA
T
U R
Z
II
A
IR
B
A S
E R
O M
A N
IA
W S
P B
E N
D
IX
R D
S T
E
V
IR
G
IN
IA
B
E A
C H
V
IR
G
IN
IA
M .W
IL
D
E
A .C
A R
T E
R
J .D
R A
K E
S .C
H
IA
N G
S E
P T
E M
B E
R
T H
W G
B -1
-D
-0
C O
N S
T R
U C
T E
D I D
A B
S /F
E V
S T
O R
A G
E
S
U B
M
IT
T A
L S
E P
T E
M B
E R
T
H
PRECAST CONCRETE
1. THE PRECAST CONCRETE SUPPLIER SHALL DESIGN THE PRECAST CONCRETE
MEMBERS AND THEIR CONNECTION IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE 2015, AND SR-EN 1992-1-3 THE LATEST
ADDITION OF THE PCI DESIGN HANDBOOK. THE PRECAST CONCRETE SUPPLIER
SHALL HAVE A LICENSED PROFESSIONAL ENGINEER SIGN AND DEAL THE
PRECAST CONCRETE CALCULATIONS AND SHOP DRAWINGS. THIS ENGINEER
SHALL ALSO PROVIDE A STATEMENT ON THE SHOP DRAWINGS STATING THAT
THE PRECAST MEMBERS AND CONNECTION ARE DESIGNED IN ACCORDANCE
WITH THE INTERNATIONAL BUILDING CODE 2015 AND SR-EN 1992-1-3.
2. COLUMN REINFORCEMENT SHALL BE DETAILED TO MEET THE SEISMIC
REQUIREMENTS FOR COLUMNS OF SPECIAL MOMENT FRAMES AS DEFINED IN
ACI 318-14 CHAPTER 17 AND P100-1/2013. MINIMUM REQUIRED REINFORCEMENT
SHOWN IN CONTRACT DRAWINGS, PRECAST CONCRETE SUPPLIER SHALL
SUBMIT SHOP DRAWINGS SHOWING REINFORCEMENT DETAILS.
3. PRECAST CONCRETE SUPPLIER SHALL COORDINATE WITH ARCHITECTURAL,
STRUCTURAL, MECHANICAL, ELECTRICAL AND CIVIL DRAWINGS FOR
LOCATIONS OF EMBEDS, OPENINGS AND PICKETS IN MEMBERS.
4. CONTRACTOR SHALL PROVIDE SLEEVES FOR MECHANICAL PIPES AND
ELECTRICAL CONDUITS THROUGH THE PRECAST MEMBERS. CONTRACTOR
SHALL VERIFY SIZE AND LOCATIONS OF ALL OPENINGS IN PRECAST MEMBERS
WITH THE TRADE REQUIRING THE SLEEVE.
5. ALL CONNECTION HARDWARE EXPOSED TO EXTERIOR CONDITIONS SHALL BE
GALVANIZED UNLESS OTHERWISE NOTED. GALVANIZED SURFACES THAT ARE
SUBSEQUENTLY FIELD WELDED SHALL BE TOUCHED-UP WITH ZINC-RICH
PAINT. CONNECTIONS BELOW GRADE SHALL NOT BE EXPOSED TO THE
SUBGRADE.
6. DETAILS AND NOTES SHOWN ON THESE DRAWINGS ARE TYPICAL. PRECAST
CONCRETE SUPPLIER SHALL BE RESPONSIBLE FOR VARIATIONS IN LENGTH,
SPECIAL DETAILS AND CONDITIONS, AND ALL REQUIRED EMBEDMENTS AS
DETAILED ON THESE DRAWINGS.
7. PRECAST CONCRETE SUPPLIER SHALL FURNISH ALL LOOSE CLIP ANGLES,
INSERTS, AND WELD PLATES NECESSARY FOR PROPER INSTALLATION.
8. PRECAST CONCRETE SUPPLIER SHALL LOCATE PICKUP POINTS, SELECT
PICKUP HARDWARE, SELECT TEMPORARY BRACING AND BE RESPONSIBLE FOR
DESIGNING AND SUPPLYING ANY ADDITIONAL REINFORCING, SHORING, ETC. AS
REQUIRED FOR ERECTION PURPOSES.
9. MEMBERS DAMAGED OR CRACKED DURING ERECTION SHALL BE REPLACED OR
REPAIRED AS DIRECTED BY THE ARCHITECT/ENGINEER.
10. MEMBER WIDTHS AND DEPTHS SHOWN ARE THE MINIMAL REQUIRED. ANY
ADDITIONAL PRECAST STRUCTURAL MEMBER DEPTH REQUIRED TO
CONSTRUCT THE BUILDINGS SHALL BE PROVIDED WITHOUT ADDITIONAL COST.
HOWEVER, THE INCREASE OF MEMBER SIZE SHALL BE APPROVED BY THE
ARCHITECT OF RECORD.
11. SHOP DRAWINGS SHALL INDICATE THE DESIGN LOADS. SHOP DRAWINGS
SHALL NOT BE SUBMITTED TO THE CONTRACTING OFFICER UNTIL REVIEWED
AND APPROVED BY THE CONTRACTOR.
12. LOCAL SOURCED PRODUCT WITH SIMILAR PROPERTIES MAY BE USED.
CONTRACTOR WILL SUBMIT PRODUCT DATA TO CONTRACTING OFFICER FOR
REVIEW AND APPROVAL.
STEEL DECK
1. TYPICAL ROOF DECK IS NON-COMPOSITE CORRUGATED, GALVANIZED STEEL
CONFORMING TO SR EN 1090-4 WITH A MINIMUM YIELD STRENGTH OF 228
MPA (33 KSI). THE STEEL ROOF DECK SHALL BE 38 mm (1 ½ INCH) DEEP TYPE
B DECK WITH THE FOLLOWING MINIMUM SECTION PROPERTIES SHOWN IN
TABLE BELOW.
THE STEEL DECK IS PART OF THE LATERAL LOAD RESISTING SYSTEM.
2. BUILDING D STEEL ROOF DECK IS 76 mm (3 INCH) DEEP, TYPE N DECK WITH
THE FOLLOWING MINIMUM SECTION PROPERTIES SHOWN IN TABLE BELOW.
THE STEEL DECK IS PART OF THE LATERAL LOAD RESISTING SYSTEM
3. ROOF DECK SHALL BE FASTENED TO THE SUPPORTING STRUCTURE WITH
16MM (5/8 INCH) Ø PUDDLE WELDS AT 36/4 WELD PATTERN FOR INTERIOR
ZONE, 36/7 FOR BOUNDARY ZONE OF 3M (10 FT). SIDE LAP CONNECTIONS
SHASLL BE MADE WITH 5MM DIAMETER (Ø10) SELF TAPPING SCREWS AT
QUARTER POINTS BETWEEN SUPPORTS, NO FURTHER THAN 300MM (12 INCH)
OC. FASTEN DISCONTINUOUS SIDE OF ROOF DECK TO SUPPORTING
STRUCTURE WITH 16MM (5/8 INCH) Ø PUDDLE WELDS AT 300MM (12 INCH) OC,
U.N.O.
4. WHERE 4 OR MORE SUPPORTS ARE PROVIDED, STEEL DECK SHALL SPAN
CONTINUOUSLY OVER A MINIMUM OF 3 SUPPORTS (2-SPAN CONDITION), UNO.
5. ALL NON-COMPOSITE STEEL DECK IS DESIGNED AS UNSHORED
CONSTRUCTION, UNO.
6. CONSTRUCTION JOINTS RUNNING PARALLEL TO BEAMS OR GIRDERS SHALL
NOT COINCIDE WITH THE CENTERLINE OF THE BEAM OR GIRDER.
7. CONSTRUCTION JOINTS RUNNING PERPENDICULAR TO BEAMS OR GIRDERS
SHALL BE LOCATED AT APPROXIMATELY THE 1/3 POINT OF THE BEAM OR
GIRDER SPAN.
8. PERMANENT SUSPENDED LOADS ARE TYPICALLY NOT SUPPORTED BY STEEL
ROOF DECK. FOR POSSIBLE EXCEPTIONS, NOTIFY EOR FOR APPROVAL.
STRUCTURAL STEEL
1. MATERIAL STRENGTH
WIDE FLANGE SHAPES, HOLLOW SECTIONS, AND ANGLES - 355JR, Fy=350 MPA
(50 KSI)
ALL OTHER STRUCTURAL STEEL - S275JR - fy= 248 MPA (36 KSI)
WELDING ELECTRODES - SR-EN 1090-2, CHAPTER 2.3 AND TABLE 5, E70XX.
FILLET WELD SIZE TYPICAL 6 mm (1/4 INCH) OR THICKNESS OF THE THINNER
METAL TO BE WELDED, U.N.O.
2. ALL STRUCTURAL STEEL ELEMENTS EXPOSED TO WEATHER SHALL BE
GALVANIZED IN ACCORDANCE WITH SR-ISO 14713 OR SR-ISO 10684, AS
APPLICABLE.
3. THE CENTER LINES OF ALL COLUMNS AND BEAMS SHALL BE LOCATED ON COLUMN
LINES U.N.O.
4. BOLTS SHALL BE 20 mm (3/4" INCH) DIAMETER, TYPE ASTM A325M (F3125 Gr 325), OR
SR-EN ISO 4017, GRADE 8.8, U.N.O. PROVIDE "STANDARD" BOLT HOLES IN
ACCORDANCE WITH AISC SR-EN 1090-2.
5. BOLT HOLES IN STEEL FIXTURES ATTACHED BY POST-INSTALLED ANCHORS SHALL
ALSO USE "STANDARD" SIZE HOLES IN SR-EN 1090-2.
6. ANCHORS SHALL CONFORM TO ASTM F1554, GRADE 55, U.N.O. HEAVY HEX ANCHOR
BOLT END ANCHORAGE ARE NOT ALLOWED.
7. SHEAR CONNECTIONS NOT DETAILED ON DRAWINGS FOR SIMPLY SUPPORTED
BEAMS SHALL BE CONNECTED BY MAXIMUM NUMBER OF BOLTS THE BEAM CAN
RECEIVE.
8. BOLTED MOMENT CONNECTIONS SHALL BE SLIP-CRITICAL CONNECTIONS. OTHER
CONNECTIONS SHALL BE BEARING CONNECTIONS WITH THREADS INCLUDED IN
SHEAR PLANES. ALL SLIP-CRITICAL CONNECTIONS SHALL BE PRETENSIONED TO
0.70 TIMES THE MINIMUM TENSILE STRENGTH OF THE BOLTS, 125 KN FOR 20 mm;
227 KN FOR 25 mm BOLTS (28 KIPS FOR 3/4"Ø A325 AND 51 KIPS FOR 1"Ø A325).
9. WHERE THE WORK OF OTHER TRADES REQUIRES CUTS, HOLES, ETC., IN
STRUCTURAL STEEL MEMBERS, CUTS, HOLES, ETC., SHALL BE MADE IN THE SHOP
AND SHOWN ON THE SHOP DRAWINGS. MAKING HOLES OR CUTS IN STRUCTURAL
STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED WITHOUT SPECIFIC
APPROVAL OF THE CONTRACTING OFFICER.
10. THE LATERAL LOAD RESISTING SYSTEM INCLUDES STRUCTURAL STEEL AND THE
DIAPHRAGM AS INDICATED BELOW. ALL ELEMENTS OF THE LATERAL LOAD
RESISTING SYSTEM INCLUDING DIAPHRAGM ARE REQUIRED TO BE COMPLETE AS
INDICATED AND DETAILED IN THE STRUCTURAL CONTRACT DOCUMENTS TO
PROVIDE THE LATERAL STRENGTH AND STABILITY OF THE STEEL STRUCTURE. THE
STRUCTURE IS CONSIDERED UNSTABLE UNTIL THESE SYSTEMS AND ELEMENTS
ARE COMPLETE.
A. THE LATERAL LOAD RESISTING SYSTEM FOR THE STEEL STRUCTURE INCLUDES
THE FOLLOWING ELEMENTS AS INDICATED AND DETAILED IN THE STRUCTURAL
CONTRACT DOCUMENTS: PRECAST CONCRETE COLUMN CONNECTION TO
FOUNDATION: MOMENT CONNECTION.
B. ROOF STEEL DECK THAT IS PROPERLY ANCHORED PER THIS SET OF
DRAWINGS.
C. ROOF DECK MEETS ALL CODE REQUIREMENTS TO FUNCTION AS A DIAPHRAGM
FOR THE LATERAL LOAD RESISTING SYSTEM. DIAPHRAGM REINFORCEMENT
BEYOND WHAT IS REQUIRED BY CIDE CAN BE ADDED PER LOCAL JURISDICTION
REQUIREMENTS.
11. STEEL BRACING: THE STABILITY OF STRUCTURAL STEEL ELEMENTS INCLUDING
INDIVIDUAL HOT-ROLLED STEEL SHAPES AND FABRICATED TRUSSES IS PROVIDED
BY THE ELEMENTS INDICATED AND DETAILED IN THE STRUCTURAL CONTRACT
DOCUMENTS. THESE ELEMENTS MUST BE COMPLETE AS SHOWN IN THE
STRUCTURAL CONTRACT DOCUMENTS BEFORE ANY TEMPORARY MEANS AND
METHODS REQUIRED FOR ERECTION ARE REMOVED.
STEEL ROOF DECK THAT IS PROPERLY ANCHORED
ALL STRUCTURAL STEEL MOMENT CONNECTIONS AND SHEAR CONNECTIONS
STEEL BRACINGS AND KICKERS
12. NON-SHRINK GROUT TYPICAL FOR BASE PLATES TO COMPLY WITH SR-EN 1090-2
CHAPTER 5.9 WITH MINIMUM COMPRESSIVE STRENGTH 48 KPA (7000 PSI) AT 28
DAYS.
13. JOISTS AND JOIST GIRDERS WITH CONCENTRATED LOADS MORE THAN 25 KG (55
LBS) ON THE TOP OR BOTTOM CHORDS NOT LOCATED AT A PANEL POINT SHALL BE
REINFORCED WITH A FIELD INSTALLED MEMBER. THE FIELD INSTALLED MEMBER
SHALL BE LOCATED AT THE CONCENTRATED LOAD AND SHALL BRACE THE CHORD
BACK TO A PANEL POINT.
SLAB-ON-GRADE
1. COMPACTED SOIL IS TO PROVIDE A SATISFACTORY SUBGRADE FOR THE
STRUCTURAL CONCRETE SLAB ON EARTH FORM. BACKFILL MATERIAL SHALL
BE GRAVELLY SOILS, WELL-GRADED SANDS, AND SAND-GRAVEL MIXTURES
RELATIVELY FREE OF PLASTIC FINES.
2. PROVIDE MINIMUM 100 mm THICK POROUS FILL LAYER DIRECTLY UNDER
VAPOR BARRIER TO PREVENT WATER CAPILLARY ACTION.
3. ISOLATION JOINTS SHALL BE USED AT JUNCTIONS WITH WALLS AND COLUMNS,
USE 15 mm THICK PREMOLDED JOINTS FULL DEPTH OF SLAB.
4. TYPICAL FLOOR SLAB THICKNESS IS 200 mm IN ALL BUILDINGS, U.N.O. PROVIDE CONTINUOUS REINFORCING STEEL MAT Ø10 AT 250 mm EACH WAY WITH 100 mm CONCRETE COVER ON TOP.
5. PROVIDE CONTROL JOINT ON SLAB SURFACE. JOINT SPACING IS SPECIFIED ON
PLAN. JOINTS SHALL BE SAWED WITHIN 24 HOURS AFTER CONCRETING.
CONTROL JOINT LOCATION IS SHOWN ON FLOOR SLAB FRAMING PLAN.
6. VAPOR BARRIER, OVERLAPPED 150 mm AT JOINTS, AND WITH A PERMEANCE
OF LESS THAN 0.3 PERMS IN ACCORDANCE WITH ASTM E-96M SHALL BE
PROVIDED UNDER INTERIOR SLAB. WHERE NO VAPOR BARRIER IS USED, THE
SUBGRADE MUST BE DAMPENED WITH WATER IN ADVANCE.
7. ANY STRUCTURAL MEMBER PENETRATING SLAB SHALL HAVE A 15MM JOINT
FILLER BETWEEN SLAB AND MEMBER COMPLYING WITH SR-EN 13670.
8. PREMATURE FINISHING IS NOT ALLOWED. IMMEDIATELY FOLLOWING
FLOATING, TROWELLING WITH STEEL TROWELS SHOULD COMMENCE IF
REQUIRED. BROOMING SHALL BE AFTER THE STEEL TROWELLING OPERATION.
9. SLAB FINISH TYPE: INSIDE BUILDING – STEEL TROWELED, U.N.O.
N O T F
N S
TR
U C
TIO
N
ROOF DECK PANEL SHAPE SECTION PROPERTY TABLE
W galvWTHICKNESS Ix Sp Sn
12.9612.480.91 122.38 2504.03 2758.93
38 10.239.760.91 26.91 1169.54 1234.52
Fy
227.59
227.59 mm kg/m2 kg/m2 mm 10 /m4 6 mm 10 /m3 3 mm 10 /m3 3 Mpa
S15014
CFS SECTION PROPERTY TABLE
D B t A kg/m Ix Sx rx Iy Sy ry
152.40 41.28 1.44 0.36 2.81 1.19 15.63 57.66 0.08 2.44 14.48 mm mm mm mm 10 kg/m mm mm2 3 mm 104 6 mm 103 3 mm 104 6 mm 103 3
T15014 157.43 38.10 1.44 0.33 2.57 1.09 13.81 57.66 0.04 1.21 10.72
S20014 203.20 41.28 1.44 0.43 3.39 2.39 23.43 74.42 0.08 2.49 13.69
S20018 203.20 50.80 1.81 0.59 4.58 3.39 33.43 76.20 0.18 4.72 17.58
T20014 208.23 38.10 1.44 0.40 3.14 2.17 20.81 73.66 0.04 1.24 9.98
76N1.0
38B1.0
DEPTH
mm
DECK TYPE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S E
U R
O P
E D
IS
T
R
IC
T D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
S-003
CTAB-GEN
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
C A
M P
IA
T
U R
Z
II
A
IR
B
A S
E R
O M
A N
IA
W S
P B
E N
D
IX
R D
S T
E
V
IR
G
IN
IA
B
E A
C H
V
IR
G
IN
IA
M .W
IL
D
E
A .C
A R
T E
R
J .D
R A
K E
S .C
H
IA
N G
S E
P T
E M
B E
R
T H
W G
B -1
-D
-0
C O
N S
T R
U C
T E
D I D
A B
S /F
E V
S T
O R
A G
E
S
U B
M
IT
T A
L S
E P
T E
M B
E R
T
H
STRUCTURAL ABBREVIATION LIST:
W/ WITH
± PLUS MINUS
Ø DIAMETER
AB ANCHOR BOLT
ACI AMERICAN CONCRETE
INSTITUTE
ADJ ADJACENT
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
ARCH ARCHITECT OR
ARCHITECTURAL
ASTM AMERICAN SOCIETY OF
TESTING AND MATERIALS
B BOTTOM
BD BAR DIAMETER
BL BASELINE
BLDG BUILDING
BM BEAM
BOS BOTTOM OF STEEL
BRG BEARING
BTWN BETWEEN
CIP CAST IN PLACE
CFS COLD FORMED STEEL
CIJB CAST IRON JUNCTION
BOX
CJ CONTRACTION JOINT
CJP COMPLETE JOINT
PENETRATION
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY
UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECT OR
CONNECTION
CONT CONTINUOUS
COORD COORDINATE
CSJ CONSTRUCTION
JOINT
CTJ CONTROL JOINT
D DEEP OR DEPTH
DEG DEGREE
DTL DETAIL
DIA DIAMETER
DWG DRAWING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EMB EMBED OR EMBEDMENT
ENG ENGINEER
EOR ENGINEER OF RECORD
ES EACH SIDE
EQ EQUAL
EW EACH WAY
EXP EXPANSION
EXT EXTERNAL
FIN FINISH OR…
This is the start of the file's text. The full file is on GovTribe.