This conceptual site plan drawing depicts proposed upgrades and renovations to the entry control facility at Graf Ignatievo, Bulgaria. Key details include designs for new inbound and outbound vehicle lanes, active and passive vehicle barriers, perimeter security fencing, entry and pedestrian gates, guard booths, walkways, and space allotted for future expansions. Demolition of existing structures such as perimeter walls and fences is also indicated. The conceptual design is intended to meet requirements outlined in the statement of work and comply with applicable safety and security standards. Verification of existing conditions on site by the contractor is required. This drawing is related to the solicitation for upgrades at the Graf Ignatievo ECP in Bulgaria being issued by the Department of the Army European Command under solicitation number W912GB-23-R-0050.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

of Engineers ®

US Army Corps

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

G E

R M

A N

Y

W

IE

S B

A D

E N

E U

R O

P E

D

IS

T R

IC

T

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S I Z

E

C H

E C

K E

D B

Y

F

IL

E N

A M

E

IS

S

U E

D A

T E

N O

C O

N T

R A

C T

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

"STOP CONTROL AVB SAFETY SCHEME" AS PER SDDCTEA PAMPHLET 55-15.

PROVIDE BEACONS, SIGNAGE AND OTHER FEATURES APPURTENANT TO THE 6.

PASSENGER VAN / BUS AND EMERGENCY VEHICLES AS DEFINED IN THE SOW.

WB-12 [WB-40] SEMITRAILER.

INCLUDING TURNING AREA FOR REJECTED VEHICLES TO ACCOMODATE A

DESIGN ROADWAYS OF THE APPROACH AND THE ACCESS CONTROL ZONE 4.

ECF TO COMPLY WITH APPLICABLE THREAT SCENARIOS AND SAFETY SCHEME.

DESIGN ROADWAYS AND VEHICLE BARRIER LOCATIONS / ALIGNMENTS OF THE 3.

ALL EXISTING CONDITIONS.

IMAGERY, GIS, AND SITE VISIT PHOTOS. CONTRACTOR MUST FIELD VERIFY

ONDITIONS SHOWN ARE THE COMBINED RESULT OF AERIAL EXISTING C2.

GENERAL NOTES:

SEE SEPARATE UTILITY DRAWINGS FOR KNOWN EXISTING UTILITIES.8.

EXITING STORM DRAINAGE CONCEPT.

DESIGN SITE GRADING AND DRAINAGE TO MATCH WITH THE OVERALL BASE'S 7.

DESIGN ROADWAYS OF THE RESPONSE ZONE TO ACCOMODATE A 5.

AND MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR.

PROVIDED DIMENSIONS ARE IN METERS AND ARE FOR INFORMATION ONLY 1.

NEW CONSTRUCTION

DEMOLITION

LAWN

PAVER BLOCK PAVEMENT (WALKWAYS)

CONCRETE PADS AND ISLANDS

ASPHALT PAVEMENT (ROADWAYS)

OPTIONAL CONSTRUCTION

EXISTING

LEGEND:

Inbound lane 61 m MIN

In s t a ll a t io n

P r o p e r t y

In s t a lla t io n

P r o p e r t y

Site Perimeter

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

CONCEPTUAL SITE PLAN

ATT. #2

C O

N C

E P

T U

A L

S

IT

E P

L A

N

G R

A F

I G

N A

T

IE

V O

B

U L

G A

R

IA

E N

T R

Y C

O N

T R

O L

F A

C

IL

IT

Y

PROPOSED OUTBOUND LANE

PROPOSED INBOUND LANE

PROPOSED ACTIVE VEHICLE BARRIER W/ K4 (M30) RATING

EXISTING PERIMETER WALL

DEMOLITION EXISTING WALLED SHOOTING POSITION

EXISTING PERIMETER FENCE

1 EXISTING GATEHOUSE

2 EXISTING PEDESTRIAN GATE

3 EXISTING VISITOR PARKING

NOTE

PROPOSED ID-CHECK LANE

6 DEMOLITION EXISTING PERIMETER FENCE

7 DEMOLITION EXISTING VEHICLE GATE

DEMOLITION EXISTING MAINTENANCE PIT

0 5 20 50

SCALE IN METERS 1:500

15 17

8 7

PROPOSED REJECTED VEHICLE TURNING AREA

(BOULDERS, BOLLARDS, JERSEY BARRIERS)

BLOCK OFF EXISTING GATE WITH PASSIVE BARRIERS

PROPOSED LIMITED USE GATE MAKING USE OF EXISTING PAVEMENT

2nd GUARD BOOTH (OPTIONAL BID ITEM)

PROPOSED PERIMETER PROTECTION (CABLE REINFORCED SECURITY FENCE)

PROPOSED GENERATOR (NOT IN SCOPE)

NOTE

PROPOSED ANTI-RAM BOLLARDS (REPEATED)

21 PROPOSED ENTRY GATE (CABLE REINFORCED DOUBLE SWING GATE)

22 PROPOSED PEDESTRIAN GATE (CABLE REINFORCED SWING GATE)

PROPOSED PASSIVE VEHICLE BARRIER SYSTEM (CABLE SYSTEM)

2nd ID-CHECK LANE / SEARCH LANE (OPTIONAL BID ITEM)

30 2nd DROP ARM (OPTIONAL BID ITEM)

BASE BID ITEMS!)CANOPY (OPTIONAL BID ITEM, FOUNDATIONS ARE

SPACE FOR FUTURE EXPANSION (E.G. 12.5m x 8.0m VISITOR CONTROL CENTER)34

SPACE FOR FUTURE EXPANSION (E.G. VISITOR PARKING)

PROPOSED GUARD BOOTH (OPTIONAL BID ITEM)

PROPOSED DROP ARM

PROPOSED BARRIER WALL

2nd BARRIER WALL (OPTIONAL BID ITEM)

18 PROPOSED WALKWAY CONNECTION

19 PROPOSED FREE STANDING ELECTRICAL DISTRIBUTION EQUIPMENT

AND PROVIDE A DESIGN THAT MEETS CODES AND REQUIREMENTS OF THE SOW.

DRAWINGS PROVIDED FOR REFERENCE ONLY. CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS

NOTE: