B.08 Att 3 SOW_Conceptual Ground Plan.pdf
PDF 782 KB Posted
- Attached to
- Mat Fire Rescue Station, Albania
- Solicitation number
- W912GB25R0038
- Issued by
-
Department of the Army European Command
About this file
This document is an Attachment #3 Conceptual Floor Plan for a design-build solicitation for a fire rescue station in Albania. The floor plan includes a detailed site layout showing a single-story building with multiple functional spaces such as a kitchen, break room, storage areas, offices, dormitory rooms, and a corridor. The site plan indicates a flat roof design with provisions for a mechanical room to house water connection points and pumps for a rooftop water tank, sized approximately 2.00m x 2.00m. The attached north elevation drawing provides a front view of the proposed structure, showing the building's basic architectural profile. The document is part of a federal contract opportunity (Solicitation Number W912GB25R0038) issued by the Department of the Army European Command for constructing a new fire and rescue station with three emergency vehicle bays, with an estimated construction magnitude between $500,000 and $1,000,000.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
15.95
.8
19.73
22.13
16.57
15.77 0.79
.1
7.
.5
20.36
0.62 15.16 4.58
22.12
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
A-101
C O
N C
EP
TU
AL
F
LO
O
R P
LA
N
M
AT
, A
LB
AN
IA
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
S
EC
TI
O
N
FI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
DESIGN-BUILD SOLICITATION
N
EW
C O
N
ST
R U
C
TI
O N
O F
FI
R
E
ST
AT
IO
N
PR
O
JE
C
T N
U M
BE
R
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR
IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL
APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.
N
0 1 5 m
1:100
SCALE
ATTACHMENT #3 CONCEPTUAL FLOOR PLANS
provide mechanical room for incoming water connection point and pumps to get water to the tank located on top of the roof. Size should be +- 2.00m x 2.00m e7eddmrh Rectangle e7eddmrh Line e7eddmrh Line e7eddmrh Arc
| Sheets |
| A-101 - CONCEPTUAL FLOOR PLAN |
File details come from the government source that posted it. Updated .