AWN-PLANS-Awnings-03.pdf

PDF 2 MB Posted

Attached to
Supply and Installation of retractable awnings at American Embassy in Buenos Aires
Solicitation number
19AR2024R0004
Issued by

About this file

This document appears to be a set of drawings and details related to a federal contract opportunity for the supply and installation of retractable awnings at the American Embassy in Buenos Aires, Argentina.

The key details are:

  • The requirement is for labor and materials to install awnings in the area of the perimeter fence to protect visa applicants from sun and rain.
  • The project has an estimated value between $200,000 and $250,000.
  • The period of performance is 65 consecutive days.
  • The contract will be a firm-fixed price type.
  • A pre-quotation conference will be held, and all contractors must be registered in the SAM database prior to submitting an offer.
  • Electronic responses are allowed, but file size is limited to 30MB.
  • The federal agency issuing the opportunity is the Department of State.

View the file

Other files

File Type Posted
RFP 19AR2024R0004 AWNING final.pdf PDF
Awnings PLANILLA SF-1442 19AR2024R0004 final.docx DOCX document
AWN-STRUCTURAL DESIGN PLANS-03.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOBBY

7.85

0.5

0.

95 0.

0.

0.

0.8

0.7

0.

0.4

4.03

4.13

4.14

4.14

4.14

4.14

4.12

2.50

4.12

4.12

4.12

4.14

4.12

4.12

4.12

2.

5.

8.65

2.

2.

1.10

1.

5.21

5.

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

0.

0.

95 0.

0.

0.

0.8

0.7

0.5

0.

4.03

4.13

4.14

4.14

4.14

4.14

4.12

2.50

4.12

4.12

4.12

4.14

4.12

4.12

4.12

2.

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

DET 01

NOTE: ALL MEASUREMENTS WILL BE VERIFIED ON SITE.

A4

AutoCAD SHX Text cad-block.com

AutoCAD SHX Text cad-block.com

AutoCAD SHX Text cad-block.com

AutoCAD SHX Text

PUBLIC STREET

AutoCAD SHX Text

RURAL SOCIETY OF ARGENTINA

AutoCAD SHX Text

RURAL SOCIETY OF ARGENTINA

AutoCAD SHX Text

PARKING LOT

AutoCAD SHX Text

PARKING LOT

AutoCAD SHX Text

AV. COLOMBIA

AutoCAD SHX Text

AV. CERVIÑO

AutoCAD SHX Text

CANOPY AND

AutoCAD SHX Text

PAVED COURTYARD

AutoCAD SHX Text

POST ONE

AutoCAD SHX Text

/ MAIN ENTRANCE

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

SOCCER

AutoCAD SHX Text

FIELD

AutoCAD SHX Text

AV COLOMBIA

AutoCAD SHX Text

AV CERVIÑO

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AV. COLOMBIA

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

AV COLOMBIA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text TITLE: DETAIL Nº1-Perimeter awning-Existing

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: 1:250

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text

DATE: 05/24/202405/24/2024

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

AutoCAD SHX Text R:02

1.

0.55 VARIABLE 0.30 4.92

4.40

2.

69 2.

2.09

3.

0.46

2.60

PUBLIC SIDEWALK

INTERIOR

(COMPOUND)

2.10

3.

0.

0.30

1.69

DET 01

0.

0.82

NOTE: ALL MEASUREMENTS WILL BE VERIFIED ON SITE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SIDEWALK SECTION

AutoCAD SHX Text

SCALE 1:50

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text

TITLE: DETAIL Nº1-SIDEWALK SECTION

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text

DATE: 05/24/202405/24/2024

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

2.10

0.52

1.69

0.25 PU

BLIC

SID

EW

ALK

3.77

2.67

IN

TER

IO

R

(C O

M

PO

U N

D

0.21

NOTE: ALL MEASUREMENTS WILL BE VERIFIED ON SITE.

AutoCAD SHX Text

DET 1

AutoCAD SHX Text

AutoCAD SHX Text

ENLARGED DETAIL OF AWNING

AutoCAD SHX Text

SCALE 1:50

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text

TITLE: DETAIL Nº1-SIDEWALK SECTION ENLARGED

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: 1:20

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text

DATE: 05/24/202405/24/2024

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

0.

0.

95 0.

0.

0.

0.8

0.7

0.5

0.

2.

60.43

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

1.

3.98

4.14

4.14

4.14

4.14

4.14

4.12

3.30

2.

AWNINGS PROJECTION

AWNINGS PROJECTION

AWNINGS PROJECTION

AWNINGS PROJECTION

AWNINGS PROJECTION

1.92

2.82

4.12

4.12

4.12

4.12

4.13

2.44

2.1 01.6

0.

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

LOBBY

7.85

0.5

0.

95 0.

0.

0.

0.8

0.7

0.

0.4

4.03

4.13

4.14

4.14

4.14

4.14

4.12

2.50

4.12

4.12

4.12

4.14

4.12

4.12

4.12

2.

5.

8.65

2.

2.

1.10

1.

5.21

5.

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

DET 01

NOTE: ALL MEASUREMENTS WILL BE VERIFIED ON SITE.

AutoCAD SHX Text

AV. COLOMBIA

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

AV COLOMBIA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text cad-block.com

AutoCAD SHX Text cad-block.com

AutoCAD SHX Text cad-block.com

AutoCAD SHX Text

PUBLIC STREET

AutoCAD SHX Text

RURAL SOCIETY OF ARGENTINA

AutoCAD SHX Text

RURAL SOCIETY OF ARGENTINA

AutoCAD SHX Text

PARKING LOT

AutoCAD SHX Text

PARKING LOT

AutoCAD SHX Text

AV. COLOMBIA

AutoCAD SHX Text

AV. CERVIÑO

AutoCAD SHX Text

CANOPY AND

AutoCAD SHX Text

PAVED COURTYARD

AutoCAD SHX Text

POST ONE

AutoCAD SHX Text

/ MAIN ENTRANCE

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

SOCCER

AutoCAD SHX Text

FIELD

AutoCAD SHX Text

AV COLOMBIA

AutoCAD SHX Text

AV CERVIÑO

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text TITLE: DETAIL Nº1-Perimeter awning-Project

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: 1:250

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text

DATE: 05/24/202405/24/2024

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

60.43

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

EXISTING PEDESTRIAN

METALIC PROTECTION ROOF

TO BE REMOVED

1.

3.98

4.14

4.14

4.14

4.14

4.14

4.12

3.30

2.

AWNINGS PROJECTION

AWNINGS PROJECTION

AWNINGS PROJECTION

AWNINGS PROJECTION

AWNINGS PROJECTION

1.92

2.82

4.12

4.12

4.12

4.12

4.13

2.1 01.6

0.

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

Circuit A - N1-70mm tubular motor Altus 50 40/12

AWNINGS

PANEL

Circuit B-70mm tubular motor Altus 50 40/12

Circuit C-70mm tubular motor Altus 50 40/12

Circuit A-N2-70mm tubular motor Altus 50 40/12

TO PANEL CAC1

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

Circuit A-N2-70mm tubular motor Altus 50 40/12

Circuit A-N2-70mm tubular motor Altus 50 40/12

Circuit A-N2-70mm tubular motor Altus 50 40/12

Circuit B-70mm tubular motor Altus 50 40/12

Circuit B-70mm tubular motor Altus 50 40/12 Circuit B-70mm tubular motor Altus 50 40/12

Circuit B-70mm tubular motor Altus 50 40/12

Circuit C-70mm tubular motor Altus 50 40/12

Circuit C-70mm tubular motor Altus 50 40/12

Circuit C-70mm tubular motor Altus 50 40/12

Circuit C-70mm tubular motor Altus 50 40/12

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1" DAISA (RMC) conduit - 4 x 2,5 + Gr 2,5mm

1"

DA

ISA

(R

MC)

co nd uit

- 4 x

2,5

Gr 2 ,5m m

NOTE: ALL MEASUREMENTS WILL BE VERIFIED ON SITE.

AutoCAD SHX Text

AV. COLOMBIA

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

AV COLOMBIA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text TITLE: Electrical installation-power and control plans

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: 1:250

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text

DATE: 05/31/202405/31/2024

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

R:00

2.10

1.69

PUBLIC

SIDEWALK

3.

2.

INTERIOR

(COMPOUND) 0.21

NOTE: ALL MEASUREMENTS WILL BE VERIFIED ON SITE.

AutoCAD SHX Text

DET 1

AutoCAD SHX Text

AutoCAD SHX Text

ENLARGED DETAIL OF AWNING

AutoCAD SHX Text

SCALE 1:50

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: 1:25

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

AutoCAD SHX Text TITLE: Electrical installation- Power plan-Elevation

AutoCAD SHX Text

DATE: 05/31/2024 05/31/2024

R:00

TUBULAR

MOTOR N1

CIRCUIT A

C. Breaker 2X10A

I.D.

2X25A 30mA

PANEL CAC1

2x 1.

m m

G r (

1.

5m m

AWNINGS PANEL AT CHACO

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

C. Breaker 2X10A

I.D.

2X25A 30mA

C. Breaker 2X10A

I.D.

2X25A 30mA

C. Breaker 4X25A

SWITCHGEAR

2x 1.

m m

G r (

1.

5m m

2x 1.

m m

G r (

1.

5m m

2x 1.

m m

G r (

1.

5m m

4x m m

G r ( 4m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

TUBULAR

MOTOR N2

CIRCUIT A

TUBULAR

MOTOR N3

CIRCUIT A

TUBULAR

MOTOR N4

CIRCUIT A

TUBULAR

MOTOR N5

CIRCUIT A

TUBULAR

MOTOR N6

CIRCUIT B

TUBULAR

MOTOR N7

CIRCUIT B

TUBULAR

MOTOR N8

CIRCUIT B

TUBULAR

MOTOR N9

CIRCUIT B

TUBULAR

MOTOR N10

CIRCUIT B

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

TUBULAR

MOTOR N11

CIRCUIT B

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

TUBULAR

MOTOR N12

CIRCUIT B

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

TUBULAR

MOTOR N13

CIRCUIT B

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

TUBULAR

MOTOR N14

CIRCUIT B

2x 1.

m m

G r (

1.

5m m

MOTOR

PROTECTION

CIRCUIT

BREAKER

1.6 A a 2.5A

GV2ME07

TUBULAR

MOTOR N15

CIRCUIT B

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text M

AutoCAD SHX Text In

AutoCAD SHX Text Im

AutoCAD SHX Text

UNCLASSIFIED

AutoCAD SHX Text

FACILITIES OFFICE BUENOS AIRES

AutoCAD SHX Text

PROPERTY:CONSULATE AWNINGS

AutoCAD SHX Text

DESIGN BY: ML GALÍNDEZ

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text

CLEARED BY: DANIELA REISNER

AutoCAD SHX Text

DRAWING Nº:

AutoCAD SHX Text

AutoCAD SHX Text

DATE: 05/31/2024 05/31/2024

AutoCAD SHX Text United States Department of State Buenos Aires Embassy Facility Management

AutoCAD SHX Text R:00

TITLE: Electrical installation-Panel schedule

Sheets and Views
A4
Sheets and Views
A4
Sheets and Views
A4
Sheets and Views
A4
Sheets and Views
A4
Sheets and Views
A4
Sheets and Views
A4

File details come from the government source that posted it. Updated .